<strong>Manual</strong> – Digital Half Cylinder 3061<br />

Page 17<br />

6.1.1 Schema<br />

Normal operation<br />

8x double beeps<br />

Residual capacity < 25%<br />

Battery warning level 1:<br />

Weak batteries<br />

Programming device<br />

Up to 15,000 operations or<br />

9 months<br />

Emergency battery -<br />

Warehouse mode<br />

Opening by system<br />

administrator only<br />

ca. 50 operations or 30<br />

days<br />

Battery warning level 2:<br />

Extremely weak batteries<br />

30 seconds of double<br />

signal beeps<br />

6.1.2 Procedure for emergency battery - warehouse mode<br />

Please proceed as follows to change the batteries if the half cylinder is in emergency<br />

battery - warehouse mode:<br />

• Replacing batteries (see chapter Battery change).<br />

• Go to the door and take a Notebook or PDA (having exported the locking<br />

plan) and a programming device with you.<br />

• Select the appropriate locking from the locking plan.<br />

• Program over the cylinder once without making any changes. This deactivates<br />

the two battery warning checkboxes and the warehouse mode.<br />

• Use the authorised transponder to engage the cylinder.<br />

The half cylinder will emit the level 2 battery warning once more after the batteries<br />

have been changed. The locking cylinder's electronic system will then detect that the<br />

batteries are at full capacity or have been replaced and the cylinder will work as normal.<br />

This procedure is only necessary in emergency battery - warehouse mode. This<br />

mode was introduced to prevent the batteries from completely discharging without intervention<br />

by the locking system administrator. Nonetheless, batteries in emergency<br />

battery - warehouse mode should be changed as soon as possible.