<strong>Manual</strong> – Digital Half Cylinder 3061<br />

Page 10<br />

The half cylinder does not engage automatically at the appointed time but remains<br />

disengaged until a subsequent command is received from the first transponder.<br />

You should select this option if you want the half cylinder to engage<br />

automatically at the appointed time.<br />

5. Transponder active<br />

• Always<br />

Transponders cannot usually be used when the door is freely accessible.<br />

However, you should select this option if you want to be able to lock a freely<br />

accessible door (for instance if everyone has left the building). In other<br />

words, if you want to manually override the time-switch.<br />

• Only when locked<br />

This mode renders transponders unable to operate a freely accessible door<br />

during the general access period.<br />

3.10 Flip-Flop<br />

Deactivates the pulse mode (default setting), the pulse length is no longer relevant.<br />

When in flip-flop mode the half cylinder will change its status from engaged to disengaged<br />

or vice versa whenever a transponder is operated. This mode is recommendable<br />

if, for instance, you want to make a door freely accessible without the use of a<br />

transponder.