<strong>Manual</strong> – Digital Half Cylinder 3061<br />

Page 8<br />

3.2 Time zone control<br />

This is only possible with the .ZK version. It is possible to load time zones which then<br />

authorise and block transponders according to their time zone group.<br />

A time zone plan also enables time-controlled switching.<br />

3.3 Overlay Modus<br />

This mode applies to the complete locking system and needs to be selected during the<br />

system's design phase. Replacement transponders can overwrite the original transponders.<br />

The first use of a replacement transponder will overwrite and block the original<br />

transponder.<br />

3.4 Extended activation<br />

The half cylinder engages the knob for approx. 5 seconds as standard. The<br />

software allows the time to be extended to 10 seconds. This does not shorten<br />

the battery life.<br />

3.5 OMRON<br />

Every product version is operable in OMRON mode. You should select this option for<br />

both the Smart Relay and the cylinder if you want the Smart Relay to transmit transponder<br />

data to a different system and subsequently send a remote opening command<br />

to a half cylinder on approval by the other system.<br />

Attention: Cylinders using this configuration cannot be opened by a transponder.<br />

Please refer to the "Smart Relay" manual for a detailed description.<br />

3.6 Warehouse mode<br />

Half cylinders are delivered in warehouse mode to preserve battery power. Half cylinders<br />

in warehouse mode cannot be addressed by a transponder. The warehouse mode<br />

is deactivated when the half cylinder is programmed for the first time. It is also possible<br />

to deactivate the warehouse mode using the programming software without creating a<br />

locking plan.<br />

For warehouse mode after battery warning level 2: see chapter 6.<br />

3.7 No acoustic programming confirmation<br />

This checkbox should be activated if you want to suppress the acoustic confirmation<br />

signal for programming or reading data from the half cylinder.