Digital Locking <strong>System</strong> <strong>3060</strong><br />

Page 5<br />

cylinder, Smart Relay or activation unit.<br />

2.6 Network 3065<br />

The cable-free Network 3065 is an online access control system that administers,<br />

visualises and archives all <strong>System</strong> <strong>3060</strong> information in one central location, and all<br />

without manipulations at the door, door frame or the door hardware.<br />

It is especially recommended for medium-sized and large locking systems in order to<br />

be able to configure and administer the locking system from a central PC. The LON<br />

standard data transmission is done from the PC over the network wiring (twisted pair)<br />

and out to the network nodes (LockNodes), which are installed near a digital<br />

component. From the LockNode, the data is directed without wires over radio<br />

transmission to the digital unit.<br />

☺<br />

While it is true that access to the network software is no longer possible if<br />

there is a power failure (unless the network has been protected by a no-break<br />

power supply), however, all of the locking system’s components that are<br />

equipped with a battery still function.<br />

2.7 Block Lock Function 3066<br />

<strong>SimonsVoss</strong> has the Block Lock Function 3066 in its product line as an option of the<br />

Digital Locking and Organization <strong>System</strong>. This function offers the possibility of<br />

activating your alarm system from a central point while at the same time preventing<br />

the monitored doors from being accidentally opened during this time. This rules out<br />

annoying and expensive false alarms right from the start.<br />

The Block Lock Function 3066 is also available as a VdS version.<br />

3.0 Digital Components With Access Logging and<br />

Time Zone Control<br />

3.1 Access Logging<br />

The Plus versions of the digital locking cylinder, SmartRelay and activation unit record<br />

the access attempts of authorised transponders. The read-out of the access list from<br />

the lockings is done using the SmartCD or, in the case of a networked locking<br />

system, over the LockNodes.<br />

A total till 128 accesses (with Smart Relay 1.024), with date, time of day and<br />

transponder designation can be stored in the access lists of the separate<br />

components. After that, the complete file isn’t deleted, but instead the oldest access is<br />

always overwritten with the new one.