<strong>Manual</strong> – Digital locking cylinder 3061<br />

Page 27<br />

9. Slide the recessed grip ring back onto the knob so that the knob and ring are flush<br />

against each other.<br />

10. Hold the assembly/battery tool against the internal knob so that both nibs fit into<br />

the openings on the ratchet disk (if necessary rotate the knob until the nibs slot into<br />

the openings).<br />

11. Lock the knob by rotating it approx. 30° in a clockwise direction (until you hear a<br />

clicking noise).<br />

Use an authorised transponder to check functionality.<br />

<br />

When replacing the batteries on a ZK version you may have to reset the<br />

time as the clock will stop running when the power supply is interrupted<br />

(software operating instructions: Programming Set locking clock time).<br />

9. Possible uses<br />

9.1 General<br />

The digital locking cylinder is designed to fit locks for Euro profile cylinders<br />

compliant with DIN 18252 and EN1303.<br />

9.2 Fire doors<br />

Installation in fire doors is possible. The locking cylinder version FH should be<br />

used for these doors and for metal doors.<br />

9.3 Doors on escape routes<br />

The .AP model should be installed in anti-panic doors where the position of<br />

the actuator can influence the functionality of the lock. The model must be<br />

approved for use by the lock manufacturer. See also chapter 2.4, standards<br />

DIN EN 179 and DIN EN 1125 and the product data sheets provided by each<br />

lock manufacturer.<br />

9.4 Outdoor installation situations<br />

Unless it is ensured that the door is completely water-proof it is recommendable to use<br />

the .WP version of each respective model. The external knob on anti-panic cylinders is<br />

completely sealed; the entire cylinder is completely sealed on the twin-knob cylinder<br />