<strong>Manual</strong> – Digital locking cylinder 3061<br />

Page 23<br />

Warning level 2: extremely weak batteries<br />

If the batteries are allowed to discharge even further, subsequent transponder<br />

operation will induce a succession of short signal tones lasting approximately<br />

30 seconds before the cylinder engages. The cylinder will not engage until<br />

after the acoustic signal has ended. The batteries are now virtually completely<br />

discharged. It is imperative they are replaced as soon as possible.<br />

Emergency battery - warehouse mode:<br />

A locking cylinder that has indicated battery warning level 2 will remain active<br />

for approximately another 50 operations, or it will shut down completely after<br />

approximately 30 days if not used. In both cases the locking cylinder will revert<br />

back to the so-called emergency battery - warehouse mode. The locking<br />

cylinder can now only engage with the help of a programming device (see<br />

chapter 6.1.3).<br />

6.1.1 Schema<br />

Normal operation<br />

8x double beeps<br />

Residual capacity < 25%<br />

Battery warning level 1:<br />

weak batteries<br />

Programming device<br />

Up to 15,000 operations or<br />

9 months<br />

Emergency<br />

battery -<br />

warehouse<br />

mode:<br />

Opening by system<br />

administrator only<br />

ca. 50 operations or 30<br />

days<br />

Battery warning level 2:<br />

Extr. weak batteries<br />

30 secs. of double<br />

signal beeps