<strong>Manual</strong> – Digital locking cylinder 3061<br />

Page 22<br />

<br />

Actuators that remain in the highest position will have no effect on the<br />

functionality of approved anti-panic locks pursuant to standards DIN<br />

EN 179 and DIN EN 1125.<br />

4. If the knob is moved slightly beyond the transition point between the areas<br />

"O" and "S" it must continue to rotate of its own accord until it reaches to<br />

the area marked "U".<br />

Otherwise realign the locking cylinder and fittings or check the lock for<br />

defects.<br />

5. Close the door and repeat the test. If the knob is difficult to rotate you will<br />

need to adjust the door or the striking plate.<br />

6. Then check the same functionality on the external knob after activating<br />

the knob with an authorised transponder (see illustration in chapter 5.4).<br />

The functionality test must be carried out for both directions of rotation.<br />

Note: European standard EN 179 Appendix C recommends that all lock<br />

components should be checked for satisfactory functionality during<br />

emergency exit locks maintenance checks at regular intervals of no<br />

more than one month.<br />

6. Battery warnings<br />

Each locking cylinder has a battery management system that indicates declining<br />

battery power in good time. This helps prevent the batteries from becoming completely<br />

discharged. The battery warning levels are described in the following.<br />

6.1 Locking cylinder<br />

Warning level 1: weak batteries<br />

When a locking cylinder's batteries are running low it will emit eight short<br />

signal tones in rapid succession when operated by a transponder before the<br />

locking cylinder engages. The batteries should be replaced without delay.<br />

Around 15,000 opening or 9 months use of the locking cylinder remain after<br />

battery warning 1 has been triggered.