01.12.2014 Views

Manual 3060 System - SimonsVoss technologies

Manual 3060 System - SimonsVoss technologies

Manual 3060 System - SimonsVoss technologies

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Manual</strong> – Digital locking cylinder 3061<br />

Page 16<br />

4.4 Emergency connection activated<br />

Locking cylinders installed within a <strong>SimonsVoss</strong> network can be permanently engaged<br />

automatically via an automated command in the programming software. The signal is<br />

usually transmitted by a fire detection system and can be interpreted by the LDB (if<br />

configured accordingly).<br />

4.5 Time-controlled opening active<br />

This box is checked if the time-switch function has been programmed and the locking<br />

cylinder engaged automatically by the time switch.<br />

4.6 Engaged<br />

This box is checked if the time-switch function or flip-flop mode has been programmed<br />

and the locking cylinder is engaged.<br />

5. Installation instructions<br />

5.1 General notes<br />

When installing the digital locking cylinder, make sure no sources of lowfrequency<br />

radio interference are located nearby. There should be at least<br />

0.5 m distance between individual locking cylinders and 1.5 m between Smart<br />

Relays or arming units.<br />

The profile cylinder housing of the locking cylinder must not protrude more<br />

than 3 mm on the outside; use a profile cylinder collar where necessary. It is<br />

also imperative that no water can enter the cylinder through the actuator area.<br />

Do not strike or hit the knobs under any circumstances during installation.<br />

Both knobs are closed by means of bayonet locks (exception: internal antipanic<br />

version).<br />

The inside part of the locking cylinder is identifiable by a sticker (IL for inside<br />

length) on the profile cylinder housing, and also by the black plastic ring<br />

located between the internal knob and the profile cylinder housing.<br />

Batteries are already installed in the unit on delivery.<br />

The installation work described in this chapter can only be executed with the<br />

installation/battery tool.