Mounting<br />
P5 and P5K<br />
Bracket BP10/30<br />
5.0<br />
Accessory for<br />
Construction<br />
P5 and P5K, supplied unless otherwise stated.<br />
Bracket and spacer in galvanised mild steel with nylon inserts for noise<br />
suppression.<br />
Optional wall distance: 10 or 30 mm to the rear of the radiator.<br />
Fig. 5.3.1 Fig. 5.3.2 Fig. 5.3.3<br />
Bracket BP10/30 Bracket BP10/30 Spacer for bracket BP10/30<br />
5.1<br />
35<br />
9<br />
35<br />
5.2<br />
Dimensions<br />
5.3<br />
5.4<br />
50/70<br />
23/43<br />
10/30<br />
70/90<br />
43/63<br />
30/50<br />
143<br />
113<br />
90<br />
143<br />
113<br />
90<br />
76<br />
30 23<br />
57<br />
NOTE: For tamperproof installation the spacer should be fixed to the wall,<br />
see page 5.3.2<br />
P5/P5K: All radiator heights 300 - 700 & 1000 mm<br />
Fig. 5.3.4<br />
P5, profile<br />
Fig. 5.3.5<br />
P5K, profile<br />
5.5<br />
5.6<br />
Fig. 5.3.6<br />
P5/P5K, all radiator heights 300 - 700 & 1000 mm, position of goal posts/rails, rear view<br />
L<br />
100<br />
B A B<br />
“A”<br />
5.7<br />
100<br />
5.8<br />
If no. of brackets is 3 or more and uneven no. of sections, the rail in the middle<br />
is displaced 17 mm towards tapping “A”.<br />
Hvor der er 3 eller flere bærebøjler og lige<br />
antal sektioner, forskydes bærebøjler i midten<br />
17mm mod anboring A for at komme op i<br />
toppen af en vandkanal.<br />
5.3.1<br />
10.2008/0
Mounting<br />
P5 and P5K<br />
Table 5.3.7<br />
P5/P5K, position of goal posts/rails and no. of brackets<br />
Tamperproof<br />
installation<br />
Radiator<br />
length L, mm<br />
No. of<br />
sections<br />
No. of brackets/spacers<br />
/goal posts<br />
A<br />
mm<br />
B<br />
mm<br />
400-600 12-18 2/2/2 - L/2<br />
633-1800 19-54 2/2/4 L-366 183<br />
1833-3600 55-108 3/3/6 (L-366)/2 183<br />
3633-4000 109-120 4/4/8 (L-366)/3 183<br />
NOTE: B = 250 mm on radiators with built-in valve or with same end<br />
connection UR Flex.<br />
Spacer can be used for tamperproof installation of radiator,<br />
see fig. 5.3.8 - 10<br />
Fig. 5.3.8 Fig. 5.3.9 Fig. 5.3.10<br />
Loosely mounted spacer Fixed spacer, elevated Spacer in fixed position<br />
for fixing<br />
5.0<br />
5.1<br />
5.2<br />
5.3<br />
5.4<br />
5.5<br />
5.6<br />
5.7<br />
5.8<br />
10.2008/0<br />
5.3.2
Mounting<br />
P5 and P5K<br />
Adjustable brackets<br />
BP28-70, BP48-90, BP68-110<br />
VARIANT<br />
5.0<br />
5.1<br />
Accessory for<br />
Application<br />
Construction<br />
P5 and P5K.<br />
For use where variable wall distance is required, or where uneven walls<br />
prevent the use of fixed brackets.<br />
Bracket in galvanised mild steel with nylon inserts for noise suppression.<br />
Spacer in galvanised mild steel with adjuster screw.<br />
Fig. 5.3.11 Fig. 5.3.12 Fig. 5.3.13<br />
Bracket BP28-70, Bracket BP28-70, Spacer for brackets<br />
BP48-90 and BP68-110 BP48-90 and BP68-110 BP28-70, BP48-90 and BP68-110<br />
5.2<br />
60<br />
20 12<br />
8<br />
50<br />
95<br />
12<br />
25<br />
5.3<br />
35<br />
5.4<br />
Dimensions<br />
Fig. 5.3.14 Fig. 5.3.15<br />
P5, radiator height P5K, radiator height<br />
300 - 700 & 1000 mm, profile 300 - 700 & 1000 mm, profile<br />
C<br />
D<br />
E<br />
C<br />
D<br />
E<br />
5.5<br />
300-700 & 1000<br />
300-700 & 1000<br />
93<br />
73<br />
61<br />
93<br />
73<br />
61<br />
5.6<br />
5.7<br />
5.8<br />
Table 5.3.16<br />
P5, wall dimensions<br />
Table 5.3.17<br />
P5K, wall dimensions<br />
Position of goal posts/<br />
rails and no. of brackets<br />
Bracket C, mm D, mm E, mm<br />
BP28-70 68-110 41-83 28-70<br />
BP48-90 88-130 61-103 48-90<br />
BP68-110 108-150 81-123 68-110<br />
Bracket C, mm D, mm E, mm<br />
BP28-70 88-130 61-103 28-70<br />
BP48-90 108-150 81-123 48-90<br />
BP68-110 128-170 101-143 68-110<br />
See pages 5.3.1 - 2<br />
5.3.3<br />
10.2008/0
Mounting<br />
P5 and P5K<br />
Adjustable feet<br />
PR<br />
VARIANT<br />
5.0<br />
Accessory for<br />
Application<br />
Construction<br />
Colour<br />
Dimensions<br />
P5/P5K with adjustable feet PR<br />
P5/P5K<br />
For use where wall mounting is not possible, e.g. in front of glazing.<br />
(cannot be retro-fitted)<br />
Adjustable feet in 2 mm rectangular steel tube rectangular, welded directly to<br />
the 3 mm steel foot plate. Mounted to floor with coach screws<br />
RAL 9010 (same as radiator)<br />
PR feet, low: 95 - 150 mm<br />
PR feet, high: 210 - 320 mm<br />
Fig. 5.3.18<br />
5.1<br />
5.2<br />
5.3<br />
PR feet, low<br />
PR feet, high<br />
P = 95 - 150 mm<br />
P = 210 - 320 mm<br />
5.4<br />
5.5<br />
Fig. 5.3.18/A<br />
P5 with feet PR, profile<br />
Fig. 5.3.18/B<br />
P5K with feet PR, profile<br />
Fig. 5.3.18/C<br />
Foot plate for feet PR,<br />
plan view<br />
114<br />
114<br />
80<br />
80<br />
5.6<br />
K<br />
K<br />
K<br />
K<br />
90<br />
90<br />
5.7<br />
3<br />
P<br />
3<br />
P<br />
10<br />
10<br />
NOTE: If rose fitted add 5 mm each side<br />
Smallest wall distance is K + thickness of skirting, see table 5.3.18/D<br />
Table 5.3.18/D<br />
Distance K for foot plate<br />
5.8<br />
Depth, mm<br />
K, mm<br />
40 37<br />
58 21<br />
10.2008/0<br />
5.3.4
Mounting<br />
P5 and P5K<br />
5.0<br />
Ordering<br />
Position and no. of feet<br />
Please state: prepared for PR feet. To avoid damage in transit, feet are not delivered<br />
attached to the radiator. The feet are supplied complete with bolts for<br />
attaching to radiator.<br />
Fig. 5.3.19<br />
Radiator with 2 feet<br />
5.1<br />
P<br />
160<br />
A 160<br />
L<br />
5.2<br />
Fig. 5.3.20<br />
Radiator with 3 feet<br />
5.3<br />
P<br />
160 A A 160<br />
5.4<br />
Fig. 5.3.21<br />
Radiator with 4 feet<br />
L<br />
5.5<br />
P<br />
5.6<br />
160<br />
A A A<br />
L<br />
160<br />
5.7<br />
5.8<br />
Table 5.3.22<br />
Position and no. of feet<br />
Radiator<br />
length L, mm<br />
No. of<br />
sections<br />
No. of<br />
feet<br />
NOTE: <strong>Hudevad</strong> do not recommend the use of feet for heights 700 and 1000 mm,<br />
without additional top restraints being used.<br />
A<br />
mm<br />
400-600 12-18 2 -<br />
633-1800 19-54 2 L-320<br />
1833-3600 55-108 3 (L-320)/2<br />
3633-4000 109-120 4 (L-320)/3<br />
5.3.5<br />
10.2008/0
Mounting<br />
P5 and P5K<br />
Console feet<br />
FH3-FH7 & FH10<br />
VARIANT<br />
5.0<br />
P5/P5K with console feet FH<br />
5.1<br />
Accessory for<br />
Application<br />
Colour<br />
Dimensions<br />
P5/P5K<br />
For use where wall mounting is not possible. The foot plate can be fixed<br />
through a raised floor or embedded in concrete. Console feet allows<br />
the radiator to be adjusted in height.<br />
Upright and foot plate: Powder coated in white RAL 9010<br />
Adjustable collars: Galvanised<br />
Fig. 5.3.23 Fig. 5.3.24 Fig. 5.3.25<br />
FH3-7 & FH10 for P5, FH3-7 & FH10 for P5K, FH3-7 & FH10, foot plate,<br />
profile profile plan view<br />
5.2<br />
5.3<br />
80<br />
100<br />
53<br />
73<br />
40<br />
60<br />
95<br />
5.4<br />
100<br />
70<br />
10<br />
20<br />
85<br />
120<br />
5.5<br />
160-230<br />
160-230<br />
5.6<br />
5<br />
25<br />
5<br />
25<br />
NOTE: If a greater or lesser height from the floor is required, taller or shorter<br />
feet FH can be selected, e.g. FH7 for radiator height 600 mm.<br />
5.7<br />
Other feet<br />
Individual solutions<br />
5.8<br />
04.2007/0<br />
5.3.6
Mounting<br />
P5 and P5K<br />
5.0<br />
5.1<br />
5.2<br />
5.3<br />
Position of<br />
rails/goal posts<br />
No. of feet and type<br />
See pages 5.3.1 - 2<br />
Table 5.3.26<br />
No. of feet FH<br />
Radiator<br />
length L, mm<br />
Table 5.3.27<br />
Type of feet FH<br />
No. of<br />
sections<br />
No. of<br />
feet<br />
400-1800 12-54 2<br />
1833-3600 55-108 3<br />
3633-4000 109-120 4<br />
Radiator<br />
height H, mm<br />
*<br />
*<br />
Height of<br />
feet, mm<br />
Type of<br />
feet<br />
300 460 FH3<br />
400 560 FH4<br />
500 660 FH5<br />
600 760 FH6<br />
700 860 FH7<br />
1000 1160 FH10<br />
* NOTE: <strong>Hudevad</strong> do not recommend the use of feet for heights 700 and<br />
1000 mm, without additional top restraints being used.<br />
5.4<br />
5.5<br />
5.6<br />
5.7<br />
5.8<br />
5.3.7<br />
04.2007/0