Mounting<br />

P5 and P5K<br />

Bracket BP10/30<br />

5.0<br />

Accessory for<br />

Construction<br />

P5 and P5K, supplied unless otherwise stated.<br />

Bracket and spacer in galvanised mild steel with nylon inserts for noise<br />

suppression.<br />

Optional wall distance: 10 or 30 mm to the rear of the radiator.<br />

Fig. 5.3.1 Fig. 5.3.2 Fig. 5.3.3<br />

Bracket BP10/30 Bracket BP10/30 Spacer for bracket BP10/30<br />

5.1<br />

35<br />

9<br />

35<br />

5.2<br />

Dimensions<br />

5.3<br />

5.4<br />

50/70<br />

23/43<br />

10/30<br />

70/90<br />

43/63<br />

30/50<br />

143<br />

113<br />

90<br />

143<br />

113<br />

90<br />

76<br />

30 23<br />

57<br />

NOTE: For tamperproof installation the spacer should be fixed to the wall,<br />

see page 5.3.2<br />

P5/P5K: All radiator heights 300 - 700 & 1000 mm<br />

Fig. 5.3.4<br />

P5, profile<br />

Fig. 5.3.5<br />

P5K, profile<br />

5.5<br />

5.6<br />

Fig. 5.3.6<br />

P5/P5K, all radiator heights 300 - 700 & 1000 mm, position of goal posts/rails, rear view<br />

L<br />

100<br />

B A B<br />

“A”<br />

5.7<br />

100<br />

5.8<br />

If no. of brackets is 3 or more and uneven no. of sections, the rail in the middle<br />

is displaced 17 mm towards tapping “A”.<br />

Hvor der er 3 eller flere bærebøjler og lige<br />

antal sektioner, forskydes bærebøjler i midten<br />

17mm mod anboring A for at komme op i<br />

toppen af en vandkanal.<br />

5.3.1<br />

10.2008/0


Mounting<br />

P5 and P5K<br />

Table 5.3.7<br />

P5/P5K, position of goal posts/rails and no. of brackets<br />

Tamperproof<br />

installation<br />

Radiator<br />

length L, mm<br />

No. of<br />

sections<br />

No. of brackets/spacers<br />

/goal posts<br />

A<br />

mm<br />

B<br />

mm<br />

400-600 12-18 2/2/2 - L/2<br />

633-1800 19-54 2/2/4 L-366 183<br />

1833-3600 55-108 3/3/6 (L-366)/2 183<br />

3633-4000 109-120 4/4/8 (L-366)/3 183<br />

NOTE: B = 250 mm on radiators with built-in valve or with same end<br />

connection UR Flex.<br />

Spacer can be used for tamperproof installation of radiator,<br />

see fig. 5.3.8 - 10<br />

Fig. 5.3.8 Fig. 5.3.9 Fig. 5.3.10<br />

Loosely mounted spacer Fixed spacer, elevated Spacer in fixed position<br />

for fixing<br />

5.0<br />

5.1<br />

5.2<br />

5.3<br />

5.4<br />

5.5<br />

5.6<br />

5.7<br />

5.8<br />

10.2008/0<br />

5.3.2


Mounting<br />

P5 and P5K<br />

Adjustable brackets<br />

BP28-70, BP48-90, BP68-110<br />

VARIANT<br />

5.0<br />

5.1<br />

Accessory for<br />

Application<br />

Construction<br />

P5 and P5K.<br />

For use where variable wall distance is required, or where uneven walls<br />

prevent the use of fixed brackets.<br />

Bracket in galvanised mild steel with nylon inserts for noise suppression.<br />

Spacer in galvanised mild steel with adjuster screw.<br />

Fig. 5.3.11 Fig. 5.3.12 Fig. 5.3.13<br />

Bracket BP28-70, Bracket BP28-70, Spacer for brackets<br />

BP48-90 and BP68-110 BP48-90 and BP68-110 BP28-70, BP48-90 and BP68-110<br />

5.2<br />

60<br />

20 12<br />

8<br />

50<br />

95<br />

12<br />

25<br />

5.3<br />

35<br />

5.4<br />

Dimensions<br />

Fig. 5.3.14 Fig. 5.3.15<br />

P5, radiator height P5K, radiator height<br />

300 - 700 & 1000 mm, profile 300 - 700 & 1000 mm, profile<br />

C<br />

D<br />

E<br />

C<br />

D<br />

E<br />

5.5<br />

300-700 & 1000<br />

300-700 & 1000<br />

93<br />

73<br />

61<br />

93<br />

73<br />

61<br />

5.6<br />

5.7<br />

5.8<br />

Table 5.3.16<br />

P5, wall dimensions<br />

Table 5.3.17<br />

P5K, wall dimensions<br />

Position of goal posts/<br />

rails and no. of brackets<br />

Bracket C, mm D, mm E, mm<br />

BP28-70 68-110 41-83 28-70<br />

BP48-90 88-130 61-103 48-90<br />

BP68-110 108-150 81-123 68-110<br />

Bracket C, mm D, mm E, mm<br />

BP28-70 88-130 61-103 28-70<br />

BP48-90 108-150 81-123 48-90<br />

BP68-110 128-170 101-143 68-110<br />

See pages 5.3.1 - 2<br />

5.3.3<br />

10.2008/0


Mounting<br />

P5 and P5K<br />

Adjustable feet<br />

PR<br />

VARIANT<br />

5.0<br />

Accessory for<br />

Application<br />

Construction<br />

Colour<br />

Dimensions<br />

P5/P5K with adjustable feet PR<br />

P5/P5K<br />

For use where wall mounting is not possible, e.g. in front of glazing.<br />

(cannot be retro-fitted)<br />

Adjustable feet in 2 mm rectangular steel tube rectangular, welded directly to<br />

the 3 mm steel foot plate. Mounted to floor with coach screws<br />

RAL 9010 (same as radiator)<br />

PR feet, low: 95 - 150 mm<br />

PR feet, high: 210 - 320 mm<br />

Fig. 5.3.18<br />

5.1<br />

5.2<br />

5.3<br />

PR feet, low<br />

PR feet, high<br />

P = 95 - 150 mm<br />

P = 210 - 320 mm<br />

5.4<br />

5.5<br />

Fig. 5.3.18/A<br />

P5 with feet PR, profile<br />

Fig. 5.3.18/B<br />

P5K with feet PR, profile<br />

Fig. 5.3.18/C<br />

Foot plate for feet PR,<br />

plan view<br />

114<br />

114<br />

80<br />

80<br />

5.6<br />

K<br />

K<br />

K<br />

K<br />

90<br />

90<br />

5.7<br />

3<br />

P<br />

3<br />

P<br />

10<br />

10<br />

NOTE: If rose fitted add 5 mm each side<br />

Smallest wall distance is K + thickness of skirting, see table 5.3.18/D<br />

Table 5.3.18/D<br />

Distance K for foot plate<br />

5.8<br />

Depth, mm<br />

K, mm<br />

40 37<br />

58 21<br />

10.2008/0<br />

5.3.4


Mounting<br />

P5 and P5K<br />

5.0<br />

Ordering<br />

Position and no. of feet<br />

Please state: prepared for PR feet. To avoid damage in transit, feet are not delivered<br />

attached to the radiator. The feet are supplied complete with bolts for<br />

attaching to radiator.<br />

Fig. 5.3.19<br />

Radiator with 2 feet<br />

5.1<br />

P<br />

160<br />

A 160<br />

L<br />

5.2<br />

Fig. 5.3.20<br />

Radiator with 3 feet<br />

5.3<br />

P<br />

160 A A 160<br />

5.4<br />

Fig. 5.3.21<br />

Radiator with 4 feet<br />

L<br />

5.5<br />

P<br />

5.6<br />

160<br />

A A A<br />

L<br />

160<br />

5.7<br />

5.8<br />

Table 5.3.22<br />

Position and no. of feet<br />

Radiator<br />

length L, mm<br />

No. of<br />

sections<br />

No. of<br />

feet<br />

NOTE: <strong>Hudevad</strong> do not recommend the use of feet for heights 700 and 1000 mm,<br />

without additional top restraints being used.<br />

A<br />

mm<br />

400-600 12-18 2 -<br />

633-1800 19-54 2 L-320<br />

1833-3600 55-108 3 (L-320)/2<br />

3633-4000 109-120 4 (L-320)/3<br />

5.3.5<br />

10.2008/0


Mounting<br />

P5 and P5K<br />

Console feet<br />

FH3-FH7 & FH10<br />

VARIANT<br />

5.0<br />

P5/P5K with console feet FH<br />

5.1<br />

Accessory for<br />

Application<br />

Colour<br />

Dimensions<br />

P5/P5K<br />

For use where wall mounting is not possible. The foot plate can be fixed<br />

through a raised floor or embedded in concrete. Console feet allows<br />

the radiator to be adjusted in height.<br />

Upright and foot plate: Powder coated in white RAL 9010<br />

Adjustable collars: Galvanised<br />

Fig. 5.3.23 Fig. 5.3.24 Fig. 5.3.25<br />

FH3-7 & FH10 for P5, FH3-7 & FH10 for P5K, FH3-7 & FH10, foot plate,<br />

profile profile plan view<br />

5.2<br />

5.3<br />

80<br />

100<br />

53<br />

73<br />

40<br />

60<br />

95<br />

5.4<br />

100<br />

70<br />

10<br />

20<br />

85<br />

120<br />

5.5<br />

160-230<br />

160-230<br />

5.6<br />

5<br />

25<br />

5<br />

25<br />

NOTE: If a greater or lesser height from the floor is required, taller or shorter<br />

feet FH can be selected, e.g. FH7 for radiator height 600 mm.<br />

5.7<br />

Other feet<br />

Individual solutions<br />

5.8<br />

04.2007/0<br />

5.3.6


Mounting<br />

P5 and P5K<br />

5.0<br />

5.1<br />

5.2<br />

5.3<br />

Position of<br />

rails/goal posts<br />

No. of feet and type<br />

See pages 5.3.1 - 2<br />

Table 5.3.26<br />

No. of feet FH<br />

Radiator<br />

length L, mm<br />

Table 5.3.27<br />

Type of feet FH<br />

No. of<br />

sections<br />

No. of<br />

feet<br />

400-1800 12-54 2<br />

1833-3600 55-108 3<br />

3633-4000 109-120 4<br />

Radiator<br />

height H, mm<br />

*<br />

*<br />

Height of<br />

feet, mm<br />

Type of<br />

feet<br />

300 460 FH3<br />

400 560 FH4<br />

500 660 FH5<br />

600 760 FH6<br />

700 860 FH7<br />

1000 1160 FH10<br />

* NOTE: <strong>Hudevad</strong> do not recommend the use of feet for heights 700 and<br />

1000 mm, without additional top restraints being used.<br />

5.4<br />

5.5<br />

5.6<br />

5.7<br />

5.8<br />

5.3.7<br />

04.2007/0