!Note • Please read rating and !CAUTION (<strong>for</strong> storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.<br />

• This catalog has only typical specifications. There<strong>for</strong>e, please approve our product specifi cations or transact the approval sheet <strong>for</strong> product specifi cations be<strong>for</strong>e ordering.<br />

R90E.pdf<br />

Sep.24,2012<br />

Inrush Current Suppression Specifications and Test Methods<br />

Item<br />

Rating Value<br />

Method of Examination<br />

Humidity Test<br />

High Temperature<br />

Continuous Load<br />

Load Cycle Test at<br />

Room Temperature<br />

ΔR/R25V±20%<br />

ΔR/R25V±20%<br />

ΔR/R25V±20%<br />

<strong>POSISTOR</strong>r is set in an environmental chamber at 85±3°C<br />

and 85% humidity <strong>for</strong> 500±4 hours.<br />

After the device is left at room temperature (25°C) <strong>for</strong> one hour,<br />

the resistance measurement is per<strong>for</strong>med.<br />

<strong>POSISTOR</strong>r is set in an environmental chamber at 85±3°C<br />

with maximum voltage applied <strong>for</strong> 500±4 hours.<br />

After the device is left at room temperature (25°C) <strong>for</strong> one hour,<br />

the resistance measurement is per<strong>for</strong>med.<br />

<strong>POSISTOR</strong>r is set in a room temperature (25±2°C) with<br />

maximum voltage applied <strong>for</strong> 1 minute, and then is left without<br />

voltage applied <strong>for</strong> 5 minutes. This cycle is repeated <strong>for</strong> 10k<br />

cycles, and after the device is left at room temperature (25°C)<br />

<strong>for</strong> one hour, the resistance measurement is per<strong>for</strong>med.<br />