3. Connections<br />

PROCEDURE STEP 2:<br />

F.I.O.<br />

User’s Manual<br />

Once all the equipment have been installed, is possible to connect them together pneumatically and electrically.<br />

-Realize the pneumatic connection of P-kit and ECU. Refer to the following instructions.<br />

ENGLISH<br />

-Realize the electrical connection between P&CD, source 230 Vac or solar panel, external antenna (optional), ECU, flow meter<br />

(optional), digital input (optional), solenoid valves. Refer to the following instructions.<br />

The line has to remain vented during this step.<br />

Note: if one of these units is not provided, don’t consider the corresponding chapter.<br />

3.1 Pneumatic connections<br />

Pict 1- Screw the compression fittings on the ECU sensors.<br />

Pict 2- Prepare the tubing for the upstream and downstream pressure measurement. Connect on ECU<br />

Pict 3- Connect on the upstream line the tubing for the pressure measurement (provide a needle valve for the isolation)<br />

Pict 4- Connect on the downstream line the tubing for the pressure measurement (provide a needle valve for the isolation)<br />

Pict 5- Connect the sensing line on the pilot<br />

Pict 6- Connect the sensing line on the multiple take-off (don’t insert needle valve through this line)<br />

Pict 7- For REFLUX / REVAL: Connect the discharge tube on the upper head.<br />

Pict 8- For APERFLUX / APERVAL : Connect the discharge tube on the pilot<br />

Pict 9- Connect the discharge tube on downstream (don’t insert needle valve through this line). Only for REFLUX / REVAL: the discharge<br />

tube of the head can be connected in the same multiple take-off of the sensing line.<br />

1 2<br />

4<br />

7 REFLUX / REVAL<br />

5 6<br />

8 APERFLUX / APERVAL 9<br />

F.I.O. User Manual – Ed.2. Rev.5 Page 11/ 53<br />