- Page 2 and 3:
MAP/Ming Visiting Professorship, En
- Page 4 and 5:
First Industrial Revolution: People
- Page 6 and 7:
The resource cycle: a massflow pers
- Page 8 and 9:
Lots of luscious low-hanging fruit:
- Page 10 and 11:
Typical areas for big industrial sa
- Page 12 and 13:
Information is cheap, powerful, but
- Page 14 and 15:
Benefits of monitoring with good gr
- Page 16 and 17:
It’s not mainly about the hardwar
- Page 18 and 19:
2. Basic hydraulic innovations www.
- Page 20 and 21:
Designing for breakthrough industri
- Page 22 and 23:
Examples from RMI’s industrial pr
- Page 24 and 25:
High efficiency doesn’t always ra
- Page 26 and 27:
New design mentality: expanding ret
- Page 28 and 29:
New design mentality • Redesignin
- Page 30 and 31:
No new technologies, just two desig
- Page 32 and 33:
This case is archetypical ◊ Most
- Page 34 and 35:
Why focus on pumping examples? ◊
- Page 36 and 37:
So how do we do this magic? “Like
- Page 38 and 39:
First seek to eliminate part or all
- Page 40 and 41:
Next, let’s minimize the piping s
- Page 42 and 43:
High-efficiency pumping / piping re
- Page 44 and 45:
Minimizing piping friction ◊ Surf
- Page 46 and 47:
Choice of valves ◊ Wide-open full
- Page 48 and 49:
Next, let’s optimize the pump The
- Page 50 and 51:
Optimize for the operating conditio
- Page 52 and 53: Chiller system efficiency (not just
- Page 54 and 55: Most induction-motor retrofits…
- Page 56 and 57: = An oil major’s 1/99 min. (EP, w
- Page 58 and 59: Prompt retrofits of induction motor
- Page 60 and 61: Premium-efficiency motors aren’t
- Page 62 and 63: Premium-efficiency motors also...
- Page 64 and 65: Capture system synergies ◊ For ex
- Page 66 and 67: Motor procurement, installation, ma
- Page 68 and 69: Putting it all together: the patter
- Page 70 and 71: Eating the Atlantic lobster ◊ Big
- Page 72 and 73: Case-study of a huge LNG plant The
- Page 74 and 75: The tasty morsels ◊ Systematicall
- Page 76 and 77: Optimized fin fan schematic V ~ 6 m
- Page 78 and 79: Heretical questions ◊ Is the plan
- Page 80 and 81: AND A NONPROPRIETARY NEW-INSTALLATI
- Page 82 and 83: Capability growth is outpacing effi
- Page 84 and 85: Intel’s nominal data-center power
- Page 86 and 87: IBM PS-2E ~5×-efficiency desktop P
- Page 88 and 89: 1U Wintel Rack Mounted Server, ~200
- Page 90 and 91: Wu-chun Feng’s Green Destiny blad
- Page 92 and 93: Some ways to cool a data center 1 r
- Page 94 and 95: Simple heat management ◊ ◊ ◊
- Page 96 and 97: IT-equipment-to-total-kW multiplier
- Page 98 and 99: Front claws: heat transfer and remo
- Page 100 and 101: The whole lobster: a fantasy ◊ Op