05.11.2012 Views

YUNG LI CO., LTD Da Pu Industrial Zone, Gang Zi, Changping Town ...

YUNG LI CO., LTD Da Pu Industrial Zone, Gang Zi, Changping Town ...

YUNG LI CO., LTD Da Pu Industrial Zone, Gang Zi, Changping Town ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

1<br />

2<br />

3<br />

4<br />

5<br />

東莞永力電業有限公司<br />

<strong>YUNG</strong> <strong>LI</strong> <strong>CO</strong>., <strong>LTD</strong><br />

<strong>Da</strong> <strong>Pu</strong> <strong>Industrial</strong> <strong>Zone</strong>, <strong>Gang</strong> <strong>Zi</strong>, <strong>Changping</strong> <strong>Town</strong>,<br />

Dong Guan City, Guangdong 523571 China.P.R.C<br />

TEL:0769-83396797~8 FAX:0769-83396796<br />

E-mail: sales@yung-li.com<br />

Description: YP-61/YC-12<br />

Customer: MAG<br />

Parts No.: CB-N-UK-3M<br />

Draw No.:<br />

<strong>YUNG</strong> <strong>LI</strong><br />

REVISION RE<strong>CO</strong>RD<br />

CHECKED PREPARED BY<br />

CUSTOMER APPROVED


SPECIFICATION<br />

TYPE DESCRIP TION PART NO. PAGE<br />

YP-61/YC-12 POWER SUPPLY <strong>CO</strong>RD 1 of 3<br />

1. S<strong>CO</strong>PE:<br />

This specification applies to POWER SUPPLY <strong>CO</strong>RDS which are in compliance<br />

with BS 1363 standards and authorized ASTA<br />

2. Standard of applicable<br />

No. Item Type Max. voltages Max. current File No.<br />

2.1 Plug YP-61 250V 10A<br />

2.2 Connector YC-12 250V 10A<br />

2.3 Cord H05VV-F 1.0/3C<br />

3. TEST <strong>CO</strong>NDITION: This test and measurement, unless otherwise specified shall be carried out at a<br />

temperature of 15 0 C to 35 0 C, relative humidity of 25% to 85%, and atmospheric<br />

pressure of 86kpa to 106kpa.<br />

However, when any doubt arises on the judgement value under it the test and<br />

measurement shall be carried out at a temperature of 20±2 0 C, relative humidity<br />

of 60% to 70%, and atmospheric pressure of 86kpa to 106kpa.<br />

4.ELECTRICAL PERFORMANCE<br />

NO. Item Test condition Requirement<br />

4-1 Dielectric<br />

Withstanding<br />

Voltage test<br />

4-2 Current and<br />

Polarity test<br />

4-3<br />

Insulation<br />

resistance test<br />

AC3000V is applied between a conductor<br />

and other conductor for 1 second.<br />

Loss of electric current at 1mA<br />

L=L<br />

E=E<br />

N=N<br />

In the air 20 0 C~60 0 C DC 500V<br />

No breakage<br />

No probl em with<br />

Conductor<br />

5MΩ/ km MIN


SPECIFICATION<br />

TYPE DESCRIP TION PART NO. PAGE<br />

YP-61/YC-12 POWER SUPPLY <strong>CO</strong>RD 2 of 3<br />

5.MECHANICAL PERFORMANCE<br />

NO. Item Test condition Requirement<br />

5-1 Aging test Exposure t o 70±2℃, at mosphere for 168 hours<br />

under natural ventilation.<br />

5-2 Input & output It is tested after taking the action of 10time<br />

Force to connector input & output.<br />

5-3 <strong>Pu</strong>lling out force<br />

of terminal<br />

5-4 <strong>Pu</strong>lling out<br />

force of cord<br />

The conn ection between bl ade terminal and<br />

conductor shall not break under a pull force of<br />

20lbs for 1minute<br />

20LBS<br />

The joint in flexible cord is to be securely supportrated<br />

by a rigid flat mounted horizontally, a pull of<br />

133.4N weight for one minute to the flexible cord<br />

133.4N<br />

No crack m ucus<br />

mark wire exposure<br />

short and oppositive<br />

polarity.<br />

Applied force is<br />

1~6kg<br />

Blade can not<br />

fall down<br />

No looseness


SPECIFICATION<br />

YP-61/YC-12 POWER SUPPLY <strong>CO</strong>RD 3 of 3<br />

6.MECHANICAL PERFORMANCE<br />

NO. Item Test condition Requirement<br />

6-1 Bending force The power supply cord division is fixing and load<br />

of 1000g is added to a tip of a cab le. It is made t o<br />

do 20000times bending on right and left each 45 0<br />

Breaking rate is<br />

under 10%<br />

(bending speed 60 times/minute)<br />

45°<br />

2000g<br />

45°<br />

YC-12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!