Black Oil System: Cold Restart<br />
• Achievable restart rates determined by:<br />
• Shut-in conditions<br />
• Fluid GOR<br />
• Water cut<br />
• Hydrate inhibitor<br />
• “Rule of Thumb”: Greater inhibitor injection rates result in<br />
lower overall inhibitor volumes used during restart<br />
• Small tiebacks: 5-10 gpm / well<br />
• Large deepwater: 25+ gpm / well<br />
• Warm-up trends:<br />
• Wellbore: Very quick (