MARCH / 2013<br />

<strong>BGC</strong> PLASTERBOARD<br />

FIRE & ACOUSTIC<br />

GUIDE<br />

Australian Owned & Manufactured<br />

www.bgc.com.au/plasterboard www.bgcinnovadesign.com.au


The <strong>BGC</strong> Plasterboard <strong>Fire</strong> <strong>and</strong> <strong>Acoustic</strong> <strong>Guide</strong> has been<br />

designed to assist architects, specifiers, designers, builders<br />

<strong>and</strong> contractors in the selection of the correct system for<br />

projects when fire <strong>and</strong> acoustic properties are required.<br />

Each of the systems in this <strong>Guide</strong> has been given a<br />

unique system number to help with ease of identification.<br />

A quick reference guide to these numbers is noted further<br />

in the <strong>Guide</strong>.<br />

The data contained in this <strong>Guide</strong> meets all Australian<br />

st<strong>and</strong>ards <strong>and</strong> is correct at the time of publication.<br />

SAFETY<br />

In normal circumstances there are no known<br />

health hazards when using or applying<br />

plasterboard. However, <strong>BGC</strong> Plasterboard<br />

recommends that the following precautions<br />

are followed.<br />

Avoid creating dust when h<strong>and</strong>ling <strong>BGC</strong><br />

Plasterboard or plasterboard products. <strong>BGC</strong><br />

Plasterboard suggests that P1 or P2 particulate<br />

respirator (dust mask), which comply with<br />

Australian <strong>and</strong> New Zeal<strong>and</strong> St<strong>and</strong>ard AS/NZS<br />

1715: Selection, Use <strong>and</strong> Maintenance of<br />

Respiratory Protective Devices, <strong>and</strong> Australian<br />

<strong>and</strong> New Zeal<strong>and</strong> St<strong>and</strong>ard AS/NZS 1716:<br />

Respiratory Protective Devices when Exposed<br />

to Dust), be used at all times.<br />

FIRST AID<br />

Eyes Flush with clean water for 15 minutes.<br />

Seek medical attention if irritation persists.<br />

Skin Wash with mild soap <strong>and</strong> water.<br />

Seek medical attention if irritation persists.<br />

Inhalation Drink plenty of water.<br />

Seek medical attention.<br />

Material Safety Data Sheets for <strong>BGC</strong> Plasterboard<br />

<strong>and</strong> <strong>BGC</strong> Fibre Cement products are available at<br />

any <strong>BGC</strong> state office or the <strong>BGC</strong> website<br />

www.bgc.com.au/plasterboard<br />

www.bgcinnovadesign.com.au<br />

INTRODUCTION TO <strong>BGC</strong> PLASTERBOARD<br />

FIRE AND ACOUSTIC GUIDE<br />

CERTIFICATION DETAILS<br />

All systems in the <strong>BGC</strong> Plasterboard <strong>Fire</strong> <strong>and</strong><br />

<strong>Acoustic</strong> <strong>Guide</strong> have been assessed to meet<br />

all requirements of Australian St<strong>and</strong>ards <strong>and</strong><br />

the Building Code of Australia.<br />

<strong>Acoustic</strong> testing has been carried out to<br />

Australian St<strong>and</strong>ards.<br />

The acoustic testing has been carried out by<br />

the following institutions:<br />

• Royal Melbourne Institute of Technology (RMIT)<br />

• CSIRO<br />

The fire testing has been carried out to Australian<br />

St<strong>and</strong>ard AS1530 – part 4 ‘<strong>Fire</strong> <strong>and</strong> Resistance<br />

Tests of Elements of Building Construction’ <strong>and</strong><br />

were carried out by:<br />

• CSIRO<br />

• Exova Warringtonfire Aus Pty Ltd.<br />

<strong>Fire</strong> <strong>and</strong> acoustic test reports <strong>and</strong> opinions can<br />

be obtained upon request. The systems detailed<br />

in this <strong>Guide</strong> <strong>and</strong> their warranties are only valid if<br />

constructed in accordance with <strong>BGC</strong> Plasterboard<br />

or <strong>BGC</strong> Fibre Cement installation methods <strong>and</strong><br />

using only <strong>BGC</strong> Plasterboard or <strong>BGC</strong> Fibre<br />

Cement products.<br />

<strong>BGC</strong> manufactures plasterboard <strong>and</strong> fibre cement<br />

products under the rigorous Quality Management<br />

System of the International St<strong>and</strong>ard ISO 9001:2008<br />

<strong>and</strong> is the holder of Licence Agreement numbers<br />

QEC 2955/13 <strong>and</strong> QEC 29633.<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

01 / GENERAL INFORMATION<br />

1


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 01 / GENERAL INFORMATION<br />

2<br />

<strong>BGC</strong> PRODUCTS<br />

<strong>BGC</strong> PLASTERBOARD<br />

PRODUCT &<br />

THICKNESS mm<br />

PLASTERBOARD<br />

10mm<br />

PLASTERBOARD<br />

13mm<br />

CEILINGBOARD<br />

13mm<br />

WATER RESISTANT<br />

PLASTERBOARD 10mm<br />

WATER RESISTANT<br />

PLASTERBOARD 13mm<br />

FIREBOARD<br />

13mm<br />

FIREBOARD<br />

16mm<br />

CURVEBOARD TM<br />

6.5mm<br />

SOUNDBOARD TM<br />

10mm<br />

SOUNDBOARD TM<br />

13mm<br />

WET AREA FIREBOARD<br />

13mm<br />

WET AREA FIREBOARD<br />

16mm<br />

IMPACTBOARD<br />

13mm<br />

<strong>BGC</strong> ENVIROBOARD<br />

COMMERCIAL<br />

<strong>BGC</strong> ENVIROBOARD<br />

ULTIMATE<br />

WEIGHT<br />

KG/M²<br />

7.00<br />

9.00<br />

7.20<br />

7.80<br />

9.40<br />

10.60<br />

12.70<br />

4.20<br />

9.00<br />

12.50<br />

10.60<br />

12.60<br />

11.50<br />

9.50<br />

10.60<br />

COMPOUNDS<br />

PRODUCT<br />

Stud Adhesive<br />

Stud Adhesive<br />

Multi Purpose Joint Compound<br />

Multi Purpose Joint Compound<br />

Water Resistant Taping Cement<br />

Water Resistant Taping Cement<br />

Lightweight All Purpose Compound<br />

Top Coat<br />

Base Coat 45<br />

Base Coat 60<br />

Base Coat 60<br />

Base Coat 60<br />

Base Coat 90<br />

Cornice Cement 45<br />

Cornice Cement 60<br />

Cornice Cement 60<br />

Cornice Cement 60<br />

Cornice Cement 90<br />

Masonry Adhesive<br />

Back Blocking Cement<br />

Exterior <strong>and</strong> Wet Area Base Coat<br />

Exterior <strong>and</strong> Wet Area Top Coat<br />

Fibreglass Tape<br />

Fibreglass Tape<br />

WIDTH<br />

mm<br />

1200<br />

1350<br />

1200<br />

1350<br />

1200<br />

1350<br />

1200<br />

1350<br />

1200<br />

1350<br />

1200<br />

1200<br />

1200<br />

1200<br />

1350<br />

1200<br />

1200<br />

1200<br />

1200<br />

1200<br />

1200<br />

LENGTH mm<br />

2400 2700 3000 3600 4200 4800 5400 6000<br />

x x x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x x x x x<br />

x<br />

BUCKET/BAG SIZE<br />

1.25kg<br />

5.2kg<br />

6kg<br />

20kg<br />

1.65kg<br />

6.4kg<br />

15kg<br />

20kg<br />

20kg<br />

5kg<br />

10kg<br />

20kg<br />

20kg<br />

20kg<br />

5kg<br />

10kg<br />

20kg<br />

20kg<br />

20kg<br />

20kg<br />

12kg<br />

13kg<br />

50mm x 20m<br />

50mm x 90m<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x


PRODUCT &<br />

THICKNESS mm<br />

DURASHEET TM 4.5mm<br />

DURASHEET TM 6.0mm<br />

DURAPLANK TM<br />

7.5MM SMOOTH AND<br />

WOODGRAIN<br />

DURAPLANK TM 7.5mm<br />

RUSTICATED<br />

NULINE TM PLUS 14.0mm<br />

DURATEX TM 7.5mm<br />

DURATEX TM 9.0mm<br />

DURALATTICE TM 6.0mm<br />

DURAGRID TM 9.0mm<br />

DURACOM TM 9.0mm<br />

DURACOM TM 12.0mm<br />

DURASCAPE TM 9.0mm<br />

DURAGROOVE TM 9.0mm<br />

COMPRESSED 15.0mm<br />

COMPRESSED 18.0mm<br />

COMPRESSED 24.0mm<br />

DURALINER TM 6.0mm<br />

DURALINER TM 9.0mm<br />

DURALINER TM 12.0mm<br />

DURALUX TM 4.5mm<br />

DURALUX TM 6.0mm<br />

*DURALUX TM 9.0mm<br />

CTU 6.0mm<br />

VCU 5.0mm<br />

STONESHEET TM 9.0mm<br />

* Available only in<br />

Queensl<strong>and</strong><br />

WEIGHT<br />

KG/M²<br />

7.58<br />

10.00<br />

2.90<br />

3.80<br />

2.50<br />

4.83<br />

4.13<br />

12.5<br />

15.38<br />

7.69<br />

11.70<br />

16.95<br />

22.73<br />

12.50<br />

12.50<br />

28.57<br />

34.48<br />

47.62<br />

10.00<br />

15.38<br />

19.00<br />

7.4<br />

9.52<br />

15<br />

9.52<br />

8.33<br />

15.38<br />

WIDTH<br />

mm<br />

1200<br />

900<br />

750<br />

600<br />

450<br />

1200<br />

900<br />

300<br />

230<br />

205<br />

205<br />

175<br />

1200<br />

900<br />

1200<br />

1200<br />

900<br />

2990<br />

1190<br />

890<br />

590<br />

1200<br />

900<br />

1200<br />

1200<br />

900<br />

1200<br />

1200<br />

900<br />

1200<br />

900<br />

1200<br />

900<br />

1200<br />

1350<br />

1200<br />

1350<br />

1200<br />

1200<br />

900<br />

1200<br />

900<br />

1200<br />

1200<br />

900<br />

900<br />

1200<br />

1190 1200 1500 1790 1800 2100 2390 2400 2440 2450 2700 2725 2750 3000 3600 4200 4800 5400 6000<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

LENGTH mm<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

<strong>BGC</strong> PRODUCTS<br />

<strong>BGC</strong> FIBRE CEMENT<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

01 / GENERAL INFORMATION<br />

3


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 01 / GENERAL INFORMATION<br />

4<br />

QUICK REFERENCE GUIDE<br />

STEEL FRAME - SINGLE STUD<br />

SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER<br />

1 x 10mm <strong>BGC</strong> Plasterboard 1 x 10mm <strong>BGC</strong> Plasterboard -/-/- S001 27<br />

1 x 13mm <strong>BGC</strong> Plasterboard 1 x 13mm <strong>BGC</strong> Plasterboard -/-/- S002 27<br />

2 x 13mm <strong>BGC</strong> Plasterboard 1 x 13mm <strong>BGC</strong> Plasterboard -/-/- S003 27<br />

2 x 13mm <strong>BGC</strong> Plasterboard 2 x 13mm <strong>BGC</strong> Plasterboard -/-/- S005 28<br />

1 x 10mm <strong>BGC</strong> Soundboard TM 1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- S006 28<br />

1 x 13mm <strong>BGC</strong> Soundboard TM 1 x 13mm <strong>BGC</strong> Soundboard TM -/-/- S007 28<br />

2 x 10mm <strong>BGC</strong> Soundboard TM 1 x 10mm <strong>BGC</strong> WR Plasterboard -/-/- S009 29<br />

2 x 10mm <strong>BGC</strong> Soundboard TM 2 x 10mm <strong>BGC</strong> Soundboard TM -/-/- S010 29<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 S011 29<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

1 x 10mm <strong>BGC</strong> Plasterboard 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 S012 30<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 S018 30<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 60/60/60 S019 30<br />

2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 S021 31<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 90/90/90 S023 31<br />

3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board - /120/120 S025 31<br />

3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/180/180 S026 32<br />

1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- S027 32<br />

1 x 9mm <strong>BGC</strong> Duraliner TM 1 x 9mm <strong>BGC</strong> Duraliner TM -/-/- S028 32<br />

1 x 12mm <strong>BGC</strong> Duraliner TM 1 x 12mm <strong>BGC</strong> Duraliner TM -/-/- S029 33<br />

1 x 10mm <strong>BGC</strong> Soundboard TM 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- S031 33<br />

1 x 13mm <strong>BGC</strong> Plasterboard 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- S033 33<br />

1 x 13mm <strong>BGC</strong> Plasterboard 1 x 9mm <strong>BGC</strong> Duraliner TM -/-/- S034 34<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- S035 34<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs) 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />

1 x 9mm <strong>BGC</strong> Duraliner TM 1 x 9mm <strong>BGC</strong> Duraliner TM -/60/60 S041 34<br />

1 x 9mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 9mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 S043 35<br />

2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board -/180/180 S044 35<br />

----- 3 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board -/120/120 120/120/120 S045 36<br />

----- 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 S046 36<br />

----- 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 120/120/120 - S048 36<br />

QUICK REFERENCE GUIDE<br />

STEEL FRAME - STAGGERED STUD<br />

SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER<br />

1 x 10mm <strong>BGC</strong> Plasterboard 1 x 10mm <strong>BGC</strong> Plasterboard -/-/- SS001 37<br />

1 x 13mm <strong>BGC</strong> Plasterboard 1 x 13mm <strong>BGC</strong> Plasterboard -/-/- SS002 37<br />

1 x 10mm <strong>BGC</strong> Soundboard TM 1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- SS006 37<br />

1 x 13mm <strong>BGC</strong> Soundboard TM 1 x 13mm <strong>BGC</strong> Soundboard TM -/-/- SS007 38<br />

2 x 10mm <strong>BGC</strong> Soundboard TM 2 x 10mm <strong>BGC</strong> Soundboard TM -/-/- SS010 38<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 SS011 38<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

1 x 13mm <strong>BGC</strong> Plasterboard 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 SS014 39<br />

2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 SS018 39<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 SS019 39<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 SS020 40<br />

2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 SS021 40<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 SS023 40<br />

3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/180/180 SS026 41<br />

1 x 9mm Duraliner TM 1 x 9mm <strong>BGC</strong> Duraliner TM -/-/- SS028 41<br />

2 x 10mm <strong>BGC</strong> Soundboard TM 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- SS032 41<br />

1 x 13mm <strong>BGC</strong> Plasterboard 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- SS033 42<br />

1 x 13mm <strong>BGC</strong> Plasterboard 1 x 9mm <strong>BGC</strong> Duraliner TM -/-/- SS034 42<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- SS035 42<br />

1 x 9mm <strong>BGC</strong> Duraliner TM 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/-/- SS036 43<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs) 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />

1 x 9mm <strong>BGC</strong> Duraliner TM 1 x 9mm <strong>BGC</strong> Duraliner TM -/60/60 SS041 43<br />

1 x 9mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 9mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 SS043 43


SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER<br />

1 x 10mm <strong>BGC</strong> Plasterboard 1 x 10mm <strong>BGC</strong> Plasterboard -/-/- SD001 44<br />

1 x 13mm <strong>BGC</strong> Plasterboard 1 x 13mm <strong>BGC</strong> Plasterboard -/-/- SD002 44<br />

1 x 10mm <strong>BGC</strong> Soundboard TM 1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- SD006 44<br />

1 x 13mm <strong>BGC</strong> Soundboard TM 1 x 13mm <strong>BGC</strong> Soundboard TM -/-/- SD007 45<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 SD011 45<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs) 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />

SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER<br />

1 x 10mm <strong>BGC</strong> Plasterboard 1 x 10mm <strong>BGC</strong> Plasterboard -/-/- T001 55<br />

1 x 13mm <strong>BGC</strong> Plasterboard 1 x 13mm <strong>BGC</strong> Plasterboard -/-/- T002 55<br />

2 x 10mm <strong>BGC</strong> Plasterboard 2 x 10mm <strong>BGC</strong> Plasterboard -/-/- T004 55<br />

2 x 13mm <strong>BGC</strong> Plasterboard 2 x 13mm <strong>BGC</strong> Plasterboard -/-/- T005 56<br />

1 x 10mm <strong>BGC</strong> Soundboard TM 1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- T006 56<br />

1 x 13mm <strong>BGC</strong> Soundboard TM 1 x 13mm <strong>BGC</strong> Soundboard TM -/-/- T007 56<br />

1 x 10mm <strong>BGC</strong> Soundboard TM 1 x 10mm <strong>BGC</strong> WR Plasterboard -/-/- T008 57<br />

2 x 10mm <strong>BGC</strong> Soundboard TM 2 x 10mm <strong>BGC</strong> Soundboard TM -/-/- T010 57<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 60/60/60 T011 57<br />

1 x 13mm <strong>BGC</strong> Plasterboard 1 x 10mm <strong>BGC</strong> Plasterboard<br />

QUICK REFERENCE GUIDE<br />

STEEL FRAME - DOUBLE STUD<br />

1 x 10mm <strong>BGC</strong> Plasterboard 1 x 10mm <strong>BGC</strong> Plasterboard -/60/60 SD016 45<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 60/60/60 SD019 46<br />

2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 90/90/90 SD021 46<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 SD023 46<br />

2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 SD024 47<br />

3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 SD025 47<br />

3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/180/180 SD026 47<br />

1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- SD027 48<br />

1 x 9mm <strong>BGC</strong> Duraliner TM 1 x 9mm <strong>BGC</strong> Duraliner TM -/-/- SD028 48<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against studs) 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />

1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 6mm <strong>BGC</strong> Duraliner TM -/60/60 SD038 48<br />

1 x 6mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 SD042 49<br />

1 x 9mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 9mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 SD043 49<br />

QUICK REFERENCE GUIDE<br />

STEEL FRAME - CINEMA WALL<br />

SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER<br />

3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 SC001 50<br />

4 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 4 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 SC002 50<br />

QUICK REFERENCE GUIDE<br />

TIMBER FRAME - SINGLE STUD<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/-/- T015 58<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 60/60/60 T019 58<br />

2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 T021 58<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 T022 59<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 T023 59<br />

3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/180/180 T026 59<br />

1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- T027 60<br />

1 x 10mm <strong>BGC</strong> Soundboard TM (against studs) 1 x 10mm <strong>BGC</strong> Soundboard TM (against studs)<br />

1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- T037 60<br />

1 x 6mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 T039 60<br />

1 x 6mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 T042 61<br />

2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board -/180/180 T044 61<br />

----- 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 T046 61<br />

----- 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/90/90 T048 62<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

01 / GENERAL INFORMATION<br />

5


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 01 / GENERAL INFORMATION<br />

6<br />

QUICK REFERENCE GUIDE<br />

TIMBER FRAME - STAGGERED STUD<br />

SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER<br />

1 x 10mm <strong>BGC</strong> Soundboard TM 1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- TS006 63<br />

2 x 10mm <strong>BGC</strong> Soundboard TM 2 x 10mm <strong>BGC</strong> Soundboard TM -/-/- TS010 63<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 TS011 63<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/90/90 TS019 64<br />

2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 TS021 64<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 TS023 64<br />

1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- TS027 65<br />

1 x 9mm <strong>BGC</strong> Duraliner TM 1 x 9mm <strong>BGC</strong> Duraliner TM -/-/- TS028 65<br />

1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 10mm <strong>BGC</strong> Plasterboard -/-/- TS030 65<br />

1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- TS031 66<br />

1 x 6mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 TS039 66<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs) 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />

1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 6mm <strong>BGC</strong> Duraliner TM 60/60/60 TS040 66<br />

1 x 6mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 TS042 67<br />

QUICK REFERENCE GUIDE<br />

TIMBER FRAME - DOUBLE STUD<br />

SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 TD011 68<br />

1 x 13mm <strong>BGC</strong> Plasterboard (against studs)1 x 13mm <strong>BGC</strong> Plasterboard (against studs)<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 TD013 68<br />

1 x 10mm <strong>BGC</strong> Plasterboard (against studs)1 x 10mm <strong>BGC</strong> Plasterboard (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 TD017 68<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 60/60/60 TD019 69<br />

2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 TD021 69<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 TD023 69<br />

3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 TD026 70<br />

1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- TD027 70<br />

1 x 9mm <strong>BGC</strong> Duraliner TM 1 x 9mm <strong>BGC</strong> Duraliner TM -/-/- TD028 70<br />

1 x 6mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 TD039 71<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs) 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />

1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 6mm <strong>BGC</strong> Duraliner TM 60/60/60 TD040 71<br />

1 x 6mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 TD042 71


QUICK REFERENCE GUIDE<br />

EXTERIOR WALL - TIMBER STUD<br />

SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER<br />

1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 60/60/60 TE001 75<br />

1 x 7.5mm Duratex TM<br />

2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 90/90/90 TE002 75<br />

1 x 7.5mm Duratex TM<br />

1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 60/60/60 TE003 75<br />

1 x 9mm Duragrid TM<br />

2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 90/90/90 TE004 76<br />

1 x 9mm Duragrid TM<br />

1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 60/60/60 TE005 76<br />

1 x 9mm Duracom TM<br />

2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 90/90/90 TE006 76<br />

1 x 9mm Duracom TM<br />

1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 60/60/60 TE007 77<br />

1 x 14mm Nuline TM Plus<br />

2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 90/90/90 TE008 77<br />

1 x 14mm Nuline TM Plus<br />

1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 60/60/60 TE009 77<br />

1 x 9mm Durascape TM<br />

2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 90/90/90 TE010 78<br />

1 x 9mm Durascape TM<br />

1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 60/60/60 TE011 78<br />

1 x 9mm Duragroove TM<br />

2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 90/90/90 TE012 78<br />

QUICK REFERENCE GUIDE<br />

EXTERIOR WALL - STEEL STUD<br />

SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER<br />

1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 SE001 79<br />

1 x 7.5mm Duratex TM<br />

2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 SE002 79<br />

1 x 7.5mm Duratex TM<br />

1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 SE003 79<br />

1 x 9mm Duragrid TM<br />

2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 SE004 80<br />

1 x 9mm Duragrid TM<br />

1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 SE005 80<br />

1 x 9mm Duracom TM<br />

2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 SE006 80<br />

1 x 9mm Duracom TM<br />

1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 SE007 81<br />

1 x 14mm Nuline TM Plus<br />

2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 SE008 81<br />

1 x 14mm Nuline TM Plus<br />

1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 SE009 81<br />

1 x 9mm Durascape TM<br />

2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 SE010 82<br />

1 x 9mm Durascape TM<br />

1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 SE011 82<br />

1 x 9mm Duragroove TM<br />

2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 SE012 82<br />

1 x 9mm Duragroove TM<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

01 / GENERAL INFORMATION<br />

7


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 01 / GENERAL INFORMATION<br />

8<br />

QUICK REFERENCE GUIDE<br />

FLOOR / CEILING - TIMBER OR STEEL JOISTS<br />

CEILING LINING FRL SYSTEM NUMBER PAGE NUMBER<br />

1 x 13mm <strong>BGC</strong> Plasterboard -/-/- C001 85<br />

2 x 13mm <strong>BGC</strong> Plasterboard -/-/- C002 85<br />

1 x 10mm <strong>BGC</strong> Ceilingboard -/-/- C003 85<br />

2 x 10mm <strong>BGC</strong> Soundboard TM -/-/- C004 86<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C005 86<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/-/- C0018 86<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C006 87<br />

3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 C007 87<br />

QUICK REFERENCE GUIDE<br />

FLOOR / CEILING - TIMBER OR STEEL JOISTS WITH FURRING CHANNELS<br />

CEILING LINING FRL SYSTEM NUMBER PAGE NUMBER<br />

1 x 10mm <strong>BGC</strong> Ceilingboard -/-/- C010 88<br />

1 x 13mm <strong>BGC</strong> Plasterboard -/-/- C011 88<br />

1 x 6mm <strong>BGC</strong> Duraliner TM (furring channel at 450mm max centres) -/-/- C012 88<br />

1 x 9mm <strong>BGC</strong> Duraliner TM -/-/- C013 89<br />

2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 C014 89<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C015 89<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C016 90<br />

3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 C017 90<br />

QUICK REFERENCE GUIDE FLOOR / CEILING - TIMBER OR STEEL<br />

JOISTS WITH FURRING CHANNELS & ACOUSTIC RESILIENT MOUNTS<br />

CEILING LINING FRL SYSTEM NUMBER PAGE NUMBER<br />

1 x 13mm <strong>BGC</strong> Plasterboard -/-/- C020 91<br />

1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- C021 91<br />

2 x 10mm <strong>BGC</strong> Soundboard TM -/-/- C022 91<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C023 92<br />

2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 C024 92<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C025 92<br />

QUICK REFERENCE GUIDE<br />

ROOF/CEILING - TIMBER TRUSSES<br />

CEILING LINING FRL SYSTEM NUMBER PAGE NUMBER<br />

1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- C030 93<br />

2 x 10mm <strong>BGC</strong> Soundboard TM -/-/- C031 93<br />

1 x 13mm <strong>BGC</strong> Plasterboard TM -/-/- C032 93<br />

1 x 13mm <strong>BGC</strong> Soundboard TM -/-/- C033 94<br />

2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 C037 94<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C034 94<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C035 95<br />

3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 C036 95


QUICK REFERENCE GUIDE<br />

ROOF/CEILING - TIMBER TRUSSES WITH FURRING CHANNELS<br />

CEILING LINING FRL SYSTEM NUMBER PAGE NUMBER<br />

1 x 10mm <strong>BGC</strong> Plasterboard -/-/- C040 96<br />

1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- C041 96<br />

1 x 13mm <strong>BGC</strong> Soundboard TM -/-/- C042 96<br />

1 x 6mm <strong>BGC</strong> Duraliner TM (furring channels at 450mm max centres) -/-/- C043 97<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C044 97<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C045 97<br />

3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 C046 98<br />

QUICK REFERENCE GUIDE ROOF/CEILING -<br />

TIMBER TRUSSES WITH FURRING CHANNELS & RESILIENT MOUNTS<br />

CEILING LINING FRL SYSTEM NUMBER PAGE NUMBER<br />

1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- C050 99<br />

2 x 10mm <strong>BGC</strong> Soundboard TM -/-/- C051 99<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C052 99<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C053 100<br />

3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 C054 100<br />

QUICK REFERENCE GUIDE<br />

COLUMNS & BEAMS<br />

LINING FRL SYSTEM NUMBER PAGE NUMBER<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 30/-/- CB01 103<br />

2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 60/-/- CB02 103<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/-/- CB03 103<br />

3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 90/-/- CB04 103<br />

3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/-/- CB05 103<br />

4 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 180/-/- CB06 103<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 30/-/- CB07 104<br />

3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 60/-/- CB08 104<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/-/- CB09 104<br />

3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/-/- CB10 104<br />

4 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 180/-/- CB11 104<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

01 / GENERAL INFORMATION<br />

9


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

STRUCTURE OF<br />

WALLS & CEILINGS<br />

STRUCTURE<br />

STEEL FRAME DESIGN<br />

AS 1170, Structural design actions – General<br />

principles defines the loads that steel framed walls are<br />

subjected to. Steel framed wall <strong>and</strong> ceiling systems<br />

must be designed according to the relevant st<strong>and</strong>ard:<br />

• AS 4100, Steel Structures<br />

• AS/NZS 4600, Cold Formed Steel Structures<br />

• AS 3623, Domestic Metal Framing<br />

• AS/NZS 2785, Suspended Ceilings.<br />

• Ensure fasteners used to fix top <strong>and</strong> bottom<br />

track are appropriate for the Uniform Distributed<br />

Loads (UDL) on walls.<br />

• At 600mm fastener centres <strong>and</strong> a UDL of<br />

0.25kPa, the fasteners must withst<strong>and</strong> a shear<br />

load of 0.75kN.<br />

• At 600mm fastener centres <strong>and</strong> a UDL of<br />

0.35kPa, the fasteners must withst<strong>and</strong> a shear<br />

load of 1.1kN.<br />

EXTERIOR WALLS AND CEILINGS<br />

Frame design of exterior wall systems must consider:<br />

INTERIOR WALLS AND CEILINGS<br />

All interior wall systems <strong>and</strong> wall height tables<br />

published in this <strong>Guide</strong> comply with the relevant<br />

section of BCA Specification C1.8.<br />

• Local environmental loading conditions<br />

(Refer to AS 1170, Structural Design Actions –<br />

General Principles)<br />

• Applied vertical load on the studs.<br />

01 / GENERAL INFORMATION 10<br />

• Height tables for non-fire rated walls have been<br />

calculated by Rondo Building Services.<br />

As a minimum, all interior wall systems published<br />

in this <strong>Guide</strong> comply with the deflection under<br />

Uniformly Distributed Load (UDL) requirements<br />

from BCA Specification C1.8. That is, the allowable<br />

deflection under a static pressure of 0.25kPa must<br />

be less than either:<br />

• Wall height ÷ 240, or<br />

• 30mm.<br />

Some applications have additional requirements<br />

such as the walls of shafts <strong>and</strong> fire isolated exits.<br />

Unusually strong wind loading conditions such as those<br />

experienced in tall buildings may require interior walls <strong>and</strong><br />

ceilings to be designed to higher pressures than<br />

the st<strong>and</strong>ard 0.25kPa. (Refer to BCA)<br />

Stud Depth<br />

70mm<br />

90mm<br />

120mm<br />

TIMBER STUD HEIGHTS<br />

Timber Grade<br />

F5<br />

F8<br />

F11<br />

F5<br />

F8<br />

F11<br />

F5<br />

F8<br />

F11<br />

CONTROL JOINTS<br />

Control joints allow for any building movement<br />

resulting from influences such as moisture migration,<br />

loading, structural movement <strong>and</strong> foundation<br />

settlement. Cracks in plasterboard <strong>and</strong> plasterboard<br />

joints can be eliminated by using control joints <strong>and</strong> the<br />

correct installation techniques. Control joints must<br />

be installed in plasterboard walls <strong>and</strong> ceilings at:<br />

• Maximum 12 metre intervals<br />

• Control joints in the structure<br />

• Any change in the substrate material.<br />

Distance between control joints may need to be<br />

reduced to less than 12 metres due to conditions<br />

such as large temperature or humidity variations.<br />

600mm 450mm<br />

Max Wall Height (m)<br />

3.1<br />

3.4<br />

3.4<br />

3.7<br />

3.4<br />

3.8<br />

3.7<br />

4.1<br />

3.6<br />

3.9<br />

3.9<br />

4.3<br />

4.0<br />

4.4<br />

4.4<br />

4.8<br />

4.4<br />

4.9<br />

4.8<br />

5.2<br />

4.6<br />

5.1<br />

4.8<br />

5.4<br />

5.4<br />

5.8<br />

5.8<br />

5.9<br />

5.9<br />

6.0<br />

6.0<br />

6.0<br />

6.0<br />

6.0<br />

6.0<br />

6.0<br />

Noggings in timber stud walls must be spaced at 1350mm max centres <strong>and</strong> must not protrude past the wall framing surface<br />

SCREW FIXINGS FOR SOFT WOOD TIMBER AND LIGHTWEIGHT STEEL FRAMING<br />

Framing<br />

Soft Wood Timber<br />

Lightweight Steel up to<br />

0.8mm thick<br />

Lightweight Steel from<br />

0.8mm to 1.6mm thick<br />

<strong>Fire</strong>board Thickness<br />

13mm<br />

16mm<br />

13mm<br />

16mm<br />

13mm<br />

16mm<br />

Stud Thickness<br />

35mm<br />

45mm<br />

35mm<br />

45mm<br />

35mm<br />

45mm<br />

35mm<br />

45mm<br />

35mm<br />

45mm<br />

35mm<br />

45mm<br />

35mm<br />

45mm<br />

35mm<br />

45mm<br />

35mm<br />

45mm<br />

Screw Type<br />

No.6 Type ‘W’<br />

No.6 Type ‘W’<br />

No.6 Type ‘S’ Needle Point<br />

No.6 Type ‘S’ Needle Point<br />

No.6 Type ‘D’ Drill Point<br />

No.6 Type ‘D’ Drill Point<br />

1st Layer<br />

32mm<br />

45mm<br />

25mm<br />

30mm<br />

32mm<br />

32mm<br />

Stud spacing<br />

Screw Length<br />

2nd Layer<br />

50mm<br />

65mm<br />

45mm<br />

45mm<br />

45mm<br />

45mm<br />

3rd Layer<br />

65mm<br />

75mm<br />

50mm<br />

65mm<br />

65mm<br />

65mm


Table 1: 0.25kPa - NON LOAD BEARING WALLS<br />

WALL FRAME<br />

AND LINING<br />

CONFIGURATION<br />

600mm CENTRES<br />

LINED BOTH SIDES<br />

600mm CENTRES<br />

ONE SIDE<br />

STAGGERED STUDS<br />

BOXED<br />

STAGGERED STUDS<br />

Table 2: 0.35kPa - NON LOAD BEARING WALLS<br />

WALL FRAME<br />

AND LINING<br />

CONFIGURATION<br />

600mm CENTRES<br />

LINED BOTH SIDES<br />

600mm CENTRES<br />

ONE SIDE<br />

STAGGERED STUDS<br />

BOXED<br />

STAGGERED STUDS<br />

Table 3: NOGGING REQUIREMENTS<br />

LINING<br />

CONFIGURATION<br />

LINED<br />

BOTH SIDES<br />

LINED<br />

ONE SIDE<br />

STAGGERED STUDS<br />

STUD SIZE<br />

BMT<br />

LININGS (mm)<br />

10<br />

13<br />

16<br />

(-/180/180)<br />

10<br />

13<br />

16<br />

10<br />

10<br />

STUD SIZE<br />

BMT<br />

LININGS (mm)<br />

10<br />

13<br />

16<br />

(-/180/180)<br />

10<br />

13<br />

16<br />

10<br />

10<br />

WALL<br />

HEIGHT<br />

0 - 4400<br />

4400 - 8800<br />

0 - 3000<br />

3000 - 6000<br />

6000 - 8000<br />

All<br />

51<br />

0.5 0.75<br />

2770 2910<br />

3200 3320<br />

3380 3520<br />

2310 2620<br />

2310 2620<br />

2310 2620<br />

51<br />

0.5 0.75<br />

2420 2550<br />

2810 2920<br />

3000 3120<br />

2070 2340<br />

2070 2340<br />

2070 2340<br />

NO. OF<br />

NOGGINGS<br />

0<br />

1<br />

1<br />

2<br />

3<br />

0<br />

STEEL STUD HEIGHTS -<br />

NON LOAD BEARING WALLS<br />

64<br />

76<br />

92<br />

0.5 0.75 1.15 0.55 0.75 1.15 0.55 0.75 1.15<br />

MAXIMUM WALL HEIGHT (mm)<br />

3330 3920 4160 3710 4420 4650 4550 4830 5110<br />

3720 4210 4420 4140 5010 5220 4950 5500 5750<br />

3910 4340 4510 4300 5250 5420 5190 5710 5930<br />

2720 3130 3520<br />

2720 3240 3570<br />

2750 3270 3590<br />

2230 2740 3300<br />

2710 3360 4160<br />

64<br />

76<br />

92<br />

0.5 0.75 1.15 0.55 0.75 1.15 0.55 0.75 1.15<br />

MAXIMUM WALL HEIGHT (mm)<br />

2930 3480 3700 3260 *3880 *4090 *4030 *4220 *4480<br />

3290 3740 3930 3650 4420 4600 4400 4840 5060<br />

3450 3830 3990 3790 4610 4770 4610 5010 5200<br />

2430 2800 3150<br />

2430 2880 3170<br />

2430 2900 3180<br />

2020 2470 2960<br />

2490 3040 3710<br />

3230 3590 4060<br />

3260 3830 4060<br />

3260 3880 4060<br />

Notes to Tables: Information provided by Rondo Building Services<br />

<strong>and</strong> as such the performances detailed are limited to the Rondo range of products<br />

Deflection limited to the lesser of H/240 or 30mm, in accordance with the BCA Specification C1.8<br />

All walls are non load bearing, except for self weight<br />

Table 1 loadings: Pultimate = 0.375kPa, Pservice = 0.25kPa<br />

Table 2 loadings: Pultimate = 0.525kPa, Pservice = 0.35kPa<br />

All loadings in accordance with AS1170:2002<br />

Walls analysed in accordance with AS/NZS4600<br />

Noggings are to be installed as per Table 3<br />

Staggered stud walls have been checked based on zero noggings, <strong>and</strong> assumed 92mm tracks<br />

Tables have been prepared by Rondo Building Services Pty Ltd<br />

The design pressures are not suitable for external wall applications<br />

The wall heights assume the stud <strong>and</strong> track sections are of the same, or similar, gauge<br />

Wall heights do not consider connection capacity, which should be checked as per Table 4<br />

*Green highlights indicate wall height may be limited by plasterboard linings<br />

3740 4160 4710<br />

3740 4210 4710<br />

3740 4220 4710<br />

150<br />

0.75 1.15<br />

*6600 *7230<br />

7030 7530<br />

7220 7650<br />

5300 *6800<br />

5300 6800<br />

5290 6800<br />

150<br />

0.75 1.15<br />

Table 4: WALL HEIGHT LIMITS BASED ON WALL LININGS<br />

LINING<br />

CONFIGURATION<br />

LINED<br />

BOTH SIDES<br />

LINED<br />

ONE SIDE<br />

STAGGERED STUDS<br />

2890 3210 3630<br />

2890 3380 3630<br />

2890 3420 3630<br />

WALL<br />

HEIGHT<br />

1 x 10mm<br />

1 x 13mm<br />

1 x 16mm<br />

0.50/0.55BMT<br />

1 x 10mm<br />

1 x 13mm<br />

1 x 16mm<br />

1 x 10mm<br />

3340 3720 *4210<br />

3340 3720 4210<br />

3340 3720 4210<br />

MAX WALL HEIGHTS<br />

0.25kPa 0.35kPa<br />

5330<br />

8000<br />

12000<br />

5330<br />

5330<br />

8000<br />

10000<br />

5330<br />

*5840 *6420<br />

*6250 *6780<br />

6410 6910<br />

*4790 *6210<br />

4790 *6210<br />

4780 6210<br />

3800<br />

5710<br />

8570<br />

3800<br />

3800<br />

5710<br />

7140<br />

3800<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

01 / GENERAL INFORMATION<br />

11


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 01 / GENERAL INFORMATION<br />

12<br />

ENVIRONMENTAL<br />

INFORMATION<br />

<strong>BGC</strong> Plasterboard shares the general community<br />

concern for the environment <strong>and</strong> seeks to reduce its<br />

environmental footprint in all aspects of its<br />

operations.<br />

Natural gypsum, the principal ingredient of<br />

<strong>BGC</strong>’s plasterboard products is mined locally at<br />

Cape Cuvier, Western Australia, which is renowned<br />

for having some of the highest purity gypsum in<br />

the world.<br />

<strong>BGC</strong> Plasterboard has set prudent environmental<br />

targets for waste minimisation <strong>and</strong> energy <strong>and</strong><br />

water use, <strong>and</strong> is an active participant in<br />

environmental reporting through the Energy<br />

Efficiency, Waterwise <strong>and</strong> Emissions reporting<br />

programs.<br />

Through strict quality control systems, production<br />

waste is minimised <strong>and</strong> wastage is recycled<br />

back into new plasterboard.<br />

GOOD ENVIRONMENTAL CHOICE AUSTRALIA<br />

Good Environmental Choice Australia is an environmental<br />

labelling program which aims to provide consumers with<br />

the knowledge that the product they are purchasing has<br />

met certain environmental performance st<strong>and</strong>ards which<br />

have been developed <strong>and</strong> assessed in line with<br />

International labelling st<strong>and</strong>ards.<br />

PRODUCT<br />

PLASTERBOARD<br />

CEILINGBOARD<br />

WATER RESISTANT BOARD<br />

SOUNDBOARD TM<br />

FIREBOARD<br />

WATER RESISTANT<br />

FIREBOARD<br />

IMPACTBOARD<br />

CURVEBOARD TM<br />

APPLICATION<br />

Scientifically recognised benchmarks for environmental<br />

performance have been developed against which<br />

products <strong>and</strong> services are assessed <strong>and</strong> evaluated to<br />

determine whether the product or service should be<br />

awarded the Good Environmental Choice Label.<br />

All <strong>BGC</strong> Plasterboard products have been certified<br />

by GECA which means that the products <strong>and</strong> their<br />

manufacturing environment have been evaluated<br />

<strong>and</strong> deemed to comply with the strict guidelines<br />

set by GECA.<br />

GECA certification is recognised by the Green Building<br />

Council of Australia <strong>and</strong> may assist in achieving up to<br />

3 Green Star points.<br />

<strong>BGC</strong>-2011<br />

GECA 04-2011v2-<br />

PANEL BOARDS<br />

• Interior Wall lining system<br />

• Suitable for residential & commercial applications<br />

• Cost Effective<br />

• Ready for decoration<br />

• Quick <strong>and</strong> simple to install<br />

• Excellent acoustic performance<br />

• Interior ceiling lining system<br />

• Suitable for residential <strong>and</strong> commercial applications<br />

• Cost effective<br />

• Quick <strong>and</strong> simple to install<br />

• Specifically designed for wet areas<br />

• Has a low absorption core<br />

• Light blue face for ease of identification<br />

• Quick <strong>and</strong> simple to install<br />

• Eliminates or greatly reduces unwanted noise travelling between rooms<br />

• Has a higher density core than st<strong>and</strong>ard plasterboard<br />

• Is ideal for upgrading the acoustic performance of existing walls or ceilings<br />

• Is lightweight <strong>and</strong> easy to install<br />

• Installation <strong>and</strong> h<strong>and</strong>ling is similar to that of st<strong>and</strong>ard board<br />

• Higher resistance to fire than st<strong>and</strong>ard plasterboard<br />

• Suitable for interior walls <strong>and</strong> ceilings<br />

• Suitable for fire isolated exits <strong>and</strong> public corridors<br />

• Quick <strong>and</strong> simple to install<br />

• Has a light pink face for ease of identification<br />

• Designed for wet areas where FRL is required<br />

• Ideal in partitioning situations<br />

• Can be used in ceilings if required<br />

• Quick <strong>and</strong> simple to install<br />

• Specifically designed for high impact areas<br />

• Suitable for residential & commercial applications<br />

• High resistance to soft body impact<br />

• Reduced indentations from hard body impact<br />

• Equivalent acoustic performance to <strong>BGC</strong> Soundboard<br />

• Stronger than st<strong>and</strong>ard 13mm plasterboard<br />

• Same installation as st<strong>and</strong>ard plasterboard<br />

• Easy to join <strong>and</strong> finish<br />

• Easy to repair<br />

• Provides design flexibility <strong>and</strong> freedom<br />

• Enables construction of contoured walls or ceilings<br />

• Allows bending to small radii<br />

• Has recessed edges on long edges to provide a continuous surface once flushed<br />

• Saves time <strong>and</strong> money on installation requiring curved surfaces<br />

• Lightweight <strong>and</strong> easy to install<br />

• Can be easily applied to timber or light-steel framing<br />

• Can be easily finished in a number of finishes


BOUNDARY/EXTERIOR WALLS<br />

Certain <strong>BGC</strong> Fibre Cement products when used in<br />

conjunction with 16mm Wet Area <strong>Fire</strong>board can achieve<br />

both 60/60/60 <strong>and</strong> 90/90/90 FRL (<strong>Fire</strong> Resistance Level)<br />

fire ratings from the outside as required by the BCA.<br />

Where an exterior wall is required to achieve 60/60/60<br />

FRL from the outside, 1 layer of 16mm Wet Area<br />

<strong>Fire</strong>board installed with certain <strong>BGC</strong> Fibre Cement<br />

products over the Wet Area <strong>Fire</strong>board will meet minimum<br />

BCA requirements.<br />

Similarly 2 layers of 16mm Wet Area <strong>Fire</strong>board used<br />

in conjunction with certain <strong>BGC</strong> Fibre Cement products<br />

will achieve 90/90/90 from the outside.<br />

There are 6 <strong>BGC</strong> Fibre Cement products that can be<br />

used in conjunction with 16mm Wet Area <strong>Fire</strong>board to<br />

achieve the fire ratings required for boundary/exterior<br />

walls. These are:<br />

• 7.5mm Duratex TM<br />

• 9.0mm Duragrid TM<br />

• 9.0mm Duracom TM<br />

• 9.0mm Durascape TM<br />

• 9.0mm Duragroove TM<br />

• 14.0mm Nuline TM Plus<br />

NOTE: All exterior walls must have sarking beneath<br />

the <strong>BGC</strong> Fibre Cement products. No adhesives are to<br />

be used when installing Wet Area <strong>Fire</strong>board <strong>and</strong> the<br />

<strong>BGC</strong> Fibre Cement products. Nails or screws must<br />

be used.<br />

EXTERIOR WALLS/<br />

BUSHFIRE INFORMATION<br />

BUSHFIRE INFORMATION<br />

AS3959:2009 sets out a series of Bushfire threat levels<br />

to buildings described as BAL (Bushfire Attack Levels)<br />

as follows:<br />

BAL-Low, BAL-12.5, BAL-19, BAL-29, BAL-40 or<br />

BAL-FZ (Flamezone).<br />

<strong>BGC</strong> Fibre Cement <strong>and</strong> <strong>BGC</strong> Plasterboard products<br />

are eminently suited for both bushfire <strong>and</strong> boundary wall<br />

applications in residential <strong>and</strong> multi residential buildings<br />

when used correctly.<br />

The chart on the next pages shows the different<br />

BAL levels that different <strong>BGC</strong> Fibre Cement <strong>and</strong> <strong>BGC</strong><br />

Plasterboard products can achieve if installed correctly.<br />

For detailed <strong>Fire</strong> <strong>and</strong> <strong>Acoustic</strong> results as well as fixing<br />

sketches for different products, please see the Exterior<br />

Wall pages in the <strong>Fire</strong> <strong>and</strong> <strong>Acoustic</strong> Data section of this<br />

guide on pages 75-82.<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

01 / GENERAL INFORMATION<br />

13


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 01 / GENERAL INFORMATION<br />

14<br />

BUSHFIRE<br />

MATRIX<br />

APPLICATIONS<br />

MATERIALS<br />

TO ENCLOSE<br />

SUBFLOOR<br />

SPACES TO<br />

BUILDINGS<br />

EXTERIOR WALLS<br />

(PARTS LESS THAN<br />

400MM FROM<br />

GROUND OR NEAR<br />

HORIZONTAL<br />

SURFACE<br />

(110MM IN<br />

WIDTH FROM WALL<br />

EXTERIOR WALLS<br />

(OTHER)<br />

EAVES LINING<br />

FASCIAS AND<br />

BARGEBOARDS<br />

BAL 12.5<br />

Durasheet TM 4.5mm<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durasheet TM 4.5mm<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durasheet TM 4.5mm<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durasheet TM 4.5mm<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

BAL 19<br />

Durasheet TM 4.5mm<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durasheet TM 4.5mm<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durasheet TM 4.5mm<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durasheet TM 4.5mm<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

BAL 29<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Nuline TM Plus 14.0mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Nuline TM Plus 14.0mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Durasheet TM 4.5mm<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

BAL 40<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Nuline TM Plus 14.0mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

BAL FZ>10m<br />

<strong>BGC</strong> system - T051<br />

Exposed side<br />

7.5mm Duratex TM or 9mm<br />

Duragrid TM or 9mm/12mm<br />

Duracom TM or 9mm<br />

Durascape TM or 9mm<br />

Duragroove TM or<br />

14mm Nuline TM Plus<br />

16mm Wet Area <strong>Fire</strong>board<br />

Unexposed Side<br />

10mm Plasterboard<br />

<strong>BGC</strong> system - T051<br />

Exposed side<br />

7.5mm Duratex TM or 9mm<br />

Duragrid TM or 9mm/12mm<br />

Duracom TM or 9mm<br />

Durascape TM or 9mm<br />

Duragroove TM or<br />

14mm Nuline TM Plus<br />

16mm Wet Area <strong>Fire</strong>board<br />

Unexposed Side<br />

10mm Plasterboard<br />

BAL FZ


APPLICATIONS<br />

GABLES (PARTS<br />

LESS THAT 400MM<br />

FROM GROUND OR<br />

NEAR HORIZONTAL<br />

SURFACE (110MM IN WIDTH<br />

FROM WALL<br />

GABLES (OTHER)<br />

MATERIALS<br />

TO ENCLOSE<br />

SUBFLOOR SPACES<br />

OF VERANDAS,<br />

DECKS STEPS,<br />

RAMPS AND<br />

LANDINGS<br />

BAL 12.5<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durasheet TM 4.5mm<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durasheet TM 4.5mm<br />

(over 400mm)<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

BAL 19<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durasheet TM 4.5mm<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durasheet TM 4.5mm<br />

(over 400mm)<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

BAL 29<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Nuline TM Plus 14.0mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Durasheet TM 4.5mm<br />

Durasheet TM 6.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 7.5mm<br />

Duratex TM 9.0mm<br />

Duraplank TM 7.5mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

BAL 40<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

Duracom TM 9.0mm<br />

Duracom TM 12.0mm<br />

Duratex TM 9.0mm<br />

Nuline TM Plus 14.0mm<br />

Durascape TM 9.0mm<br />

Duragroove TM 9.0mm<br />

BAL FZ>10m<br />

BUSHFIRE<br />

MATRIX<br />

BAL FZ


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 01 / GENERAL INFORMATION<br />

16


SOUND INSULATION<br />

Every partition has a sound insulation rating.<br />

A very basic partition may have a sound insulation<br />

rating of approximately R w 30. A cinema partition on<br />

the other h<strong>and</strong> may have a rating of around R w 70.<br />

BASIC WALL<br />

S001<br />

The R w value is the sound insulation rating, for<br />

airborne sound. STC is another sound insulation<br />

rating. However STC is no longer in common<br />

use in Australia.<br />

A higher R w rating means a better partition for<br />

sound insulation. Airborne sound insulation ratings<br />

can range from as low as R w 10 -15 up to values<br />

of R w 75 <strong>and</strong> greater. Examples of R w ratings for<br />

different types of partitions are shown below.<br />

CONSTRUCTION<br />

S001<br />

S010<br />

SS010<br />

SD023<br />

SD025<br />

R w 30 R w 70<br />

Typical<br />

R w<br />

30<br />

40<br />

55<br />

65<br />

70<br />

CINEMA WALL<br />

SC001<br />

EG: PARTITIONS<br />

SEPARATING:<br />

RETAIL<br />

TENANCIES<br />

PRIVATE<br />

OFFICES<br />

BOARD<br />

ROOMS<br />

APARTMENTS<br />

CINEMAS<br />

Sometimes the R w value includes a C tr rating,<br />

R w + C tr . C tr is a sound insulation rating for<br />

low-frequency noise, like trucks <strong>and</strong> stereo<br />

subwoofers.<br />

For example, the R w 40 partition below<br />

has a C tr rating of -10.<br />

S002<br />

R w 40<br />

C tr -10<br />

R w + C tr 30<br />

ACOUSTICS<br />

Here, the combined sound insulation rating<br />

is R w + C tr 30.<br />

C tr is a negative number <strong>and</strong> values typically<br />

range from about -4 to about -12. The C tr<br />

rating depends on the mass of the partition.<br />

A heavier partition will have a smaller C tr rating.<br />

Choosing the right partition for the job means<br />

choosing a partition with the right sound insulation<br />

rating. If acoustics is important for your project,<br />

we recommend that you contact a qualified<br />

acoustic consultant for advice.<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

17<br />

02 / ACOUSTIC INFORMATION


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 18<br />

02 / ACOUSTIC INFORMATION<br />

ACOUSTICS<br />

BUILDING CODE OF AUSTRALIA:<br />

WHO, WHAT, WHY AND HOW?<br />

Who?<br />

The Building Code of Australia (BCA) sets acoustic<br />

ratings for residential buildings.<br />

What?<br />

The BCA sets acoustic ratings for a range of buildings<br />

including apartments, hotels, student accommodation<br />

<strong>and</strong> aged-care buildings. The acoustic ratings are for<br />

inter-tenancy walls <strong>and</strong> floors in these buildings.<br />

For example, a wall between two apartments should<br />

have an airborne sound insulation rating of R w +C tr 50.<br />

<strong>Acoustic</strong> ratings also apply to entry doors <strong>and</strong> to<br />

services such as ducting <strong>and</strong> water, soil <strong>and</strong> waste<br />

pipes in the inter-tenancy walls, floors <strong>and</strong> riser shafts.<br />

Why?<br />

The BCA ratings are a minimum acoustic st<strong>and</strong>ard for<br />

residential buildings. This means that someone living<br />

in an apartment can expect a reasonable amount of<br />

acoustic privacy from their neighbours.<br />

The BCA ratings are a minimum st<strong>and</strong>ard. Apartments<br />

<strong>and</strong> buildings built to a higher quality level generally<br />

require walls <strong>and</strong> floors which exceed BCA st<strong>and</strong>ards.<br />

How?<br />

Different sound insulation ratings apply to different<br />

building elements, depending on the rooms being<br />

separated. In some cases ratings include the C tr .<br />

Some cases also include a requirement for the partition<br />

to be discontinuous (see below for further discussion).<br />

The specific acoustic requirements from the BCA are<br />

detailed in the table below.<br />

BCA INTER-TENANCY AIRBORNE SOUND INSULATION REQUIREMENTS<br />

Inter-tenancy partition<br />

Wall separating habitable rooms<br />

such as living areas <strong>and</strong> bedrooms<br />

Wall separating wet areas<br />

such as bathrooms <strong>and</strong> laundries<br />

Wall separating a wet area or<br />

kitchen from a habitable room<br />

Wall separating a sole-occupancy<br />

unit from a stairway, public corridor,<br />

public lobby, etc<br />

Wall separating a sole-occupancy<br />

unit from a plant room or lift shaft<br />

Floor separating<br />

sole-occupancy units<br />

Floor separating a sole-occupancy<br />

unit from a plant room, lift shaft,<br />

stairway, public corridor, public<br />

lobby or the like<br />

Door separating a sole-occupancy<br />

unit from a public corridor, public<br />

lobby, etc<br />

Wall, floor or riser separating a duct,<br />

soil, waste or water supply pipe from<br />

a habitable room<br />

Wall floor or riser separating a duct,<br />

soil, waste or water supply pipe from<br />

a wet area or kitchen<br />

Sound insulation<br />

R w + C tr ≥ 50<br />

R w + C tr ≥ 50<br />

R w + C tr ≥ 50<br />

R w ≥ 50<br />

R w ≥ 50<br />

R w + C tr ≥ 50<br />

R w + C tr ≥ 50<br />

R w ≥ 30<br />

R w + C tr ≥ 40<br />

R w + C tr ≥ 25<br />

Notes<br />

Note: BCA Requirements in Queensl<strong>and</strong> <strong>and</strong> Northern Territory differ from those stated in the table above.<br />

<strong>BGC</strong> recommends further investigation as to BCA requirements in Queensl<strong>and</strong> <strong>and</strong> Northern Territory.<br />

Wall impact isolation not required<br />

Wall impact isolation not required<br />

Discontinuous construction required<br />

Wall impact isolation not required<br />

Discontinuous construction required<br />

Floor impact isolation criteria<br />

also apply<br />

Floor impact isolation treatment<br />

also required


The figure below shows an example of the type of acoustic performance required to inter-tenancy<br />

partitions separating two apartments.<br />

R w + C tr ≥ 50 discontinuous<br />

R w + C tr ≥ 50<br />

R w ≥ 50<br />

KITCHEN<br />

BEDROOM<br />

LIVING<br />

BATHROOM<br />

CORRIDOR<br />

BATHROOM<br />

BEDROOM<br />

BEDROOM<br />

Example of BCA performance requirements for different sections of inter-tenancy partitions<br />

The acoustic performance of the wall depends on<br />

the type of room on each side of the partition.<br />

For example, where the wall separates a bedroom or<br />

living area in one apartment from a wet area such as<br />

APARTMENT INTER-TENANCY WALL<br />

Where acoustic amenity is required to exceed<br />

the BCA minimum performance requirement,<br />

<strong>BGC</strong> recommend wall system SD021 for inter-tenancy<br />

walls between apartments.<br />

SD021<br />

ACOUSTICS<br />

KITCHEN<br />

LIVING<br />

a kitchen or bathroom in another apartment, the<br />

partition should be of discontinuous construction.<br />

The acoustic performance of a partition between<br />

an apartment <strong>and</strong> a common corridor does not<br />

include the Ctr.<br />

<strong>BGC</strong> RECOMMENDED<br />

WALL TYPE<br />

The system has been laboratory tested to<br />

R w 65 <strong>and</strong> R w + C tr 58.<br />

This wall system is classified as a discontinuous<br />

construction <strong>and</strong> exceeds the inter-tenancy partition<br />

requirements of the BCA. It will provide a good level<br />

of acoustic separation around an apartment <strong>and</strong> is<br />

recommended for all apartment types up to<br />

medium-to-high quality.<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

02 / ACOUSTIC INFORMATION<br />

19


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 02 / ACOUSTIC INFORMATION<br />

20<br />

ACOUSTIC<br />

CONCEPTS<br />

INSULATION IN WALL, FLOOR AND ROOF<br />

CONSTRUCTIONS<br />

<strong>Acoustic</strong> ratings in this <strong>Guide</strong> are provided for two<br />

different types of polyester insulation: 50mm thick,<br />

9kg/m3 polyester <strong>and</strong> 75mm thick, 30kg/m3.<br />

Fibreglass insulation of the same thickness <strong>and</strong> mass<br />

may be used in lieu of these two types of polyester<br />

without changing the acoustic ratings.<br />

ON-SITE PERFORMANCE<br />

In an acoustic laboratory, sound insulation ratings<br />

are measured using purpose built rooms which give<br />

very accurate, reproducible results. The Rw value<br />

is a laboratory result.<br />

Things are not so simple on site. For example,<br />

the rating of a wall can be affected by the floor it<br />

is mounted on, the overhead ceiling, the side walls<br />

<strong>and</strong> any penetrations <strong>and</strong> services which run through<br />

the wall or floor above. The DnT,w value is an on<br />

site result.<br />

The Rw <strong>and</strong> DnT,w values are similar in concept but<br />

are not the same. The difference is the DnT,w accounts<br />

for the imperfect testing conditions found on site.<br />

As a guide, the DnT,w value of a partition is typically<br />

around 5dB lower than the Rw value.<br />

The Ctr correction can be applied to both Rw<br />

<strong>and</strong> DnT,w ratings. For example, the BCA states that<br />

walls separating adjacent apartments should have a<br />

minimum DnT,w + Ctr 45 rating, when site verification<br />

is being used for assessment purposes.<br />

FLANKING<br />

Flanking transmission means sound transmission<br />

around the partition rather than through it.<br />

Flanking transmission can occur when the floor,<br />

walls or ceiling around a separating partition have<br />

poor sound insulation, which decreases the<br />

performance of the separating partition.<br />

Flanking Flanking transmission sound is common transmission<br />

site <strong>and</strong><br />

should be carefully assessed.<br />

IMPACT SOUND AND DISCONTINUITY<br />

So far, we have covered airborne sound which means<br />

sound such as voices <strong>and</strong> audio-speakers which travels<br />

through air. Impact sound means sound generated from<br />

impact on the partitions <strong>and</strong> floors of the building.<br />

For example, if someone walks on their tiled floor,<br />

a person on the floor beneath will hear the impact<br />

sound. Another example is someone closing a kitchen<br />

cupboard. If the cupboard is connected to the wall,<br />

a person on the other side of the wall will hear the<br />

impact sound from the cupboard door. For example,<br />

double stud partitions are discontinuous <strong>and</strong> single<br />

steel studs partitions are not.<br />

Impact sound<br />

In the BCA some partitions need to provide wall<br />

impact isolation. For example, a partition between<br />

a kitchen or bathroom in one apartment <strong>and</strong> a living<br />

room or bedroom in another apartment should have<br />

a discontinuous construction. This means the partition<br />

should include a structural break.<br />

There are a number of resilient acoustic mounts<br />

available in the market place. It is critical that a suitable<br />

resilient acoustic mount be selected in order for wall,<br />

floor or roof construction to achieve the acoustic<br />

rating. Good quality resilient acoustic mounts should<br />

be selected <strong>and</strong> loaded appropriately to ensure that<br />

static deflection is sufficient to achieve good acoustic<br />

performance. A suitable static deflection is typically<br />

around 5mm. Rondo <strong>and</strong> Embelton supply suitable<br />

resilient acoustic mounts.


CONTINUOUS CONSTRUCTION e.g. S001<br />

S001<br />

DISCONTINUOUS CONSTRUCTION e.g. SD019<br />

SD019<br />

QUALITY CONSTRUCTIONS / GENERAL DETAILING<br />

Quality on-site construction is critical to achieve a<br />

good level of acoustic performance in any building<br />

project. Small gaps <strong>and</strong> holes can often occur in<br />

<strong>and</strong> around a wall or floor. If these are left untreated<br />

they significantly down-rate the acoustic performance.<br />

Any gaps <strong>and</strong> holes must be minimised. Gaps <strong>and</strong><br />

holes which do occur, including those around services<br />

penetrations, should be acoustically sealed to<br />

minimise the leakage effect on acoustic performance.<br />

ACOUSTIC<br />

CONCEPTS<br />

ACOUSTIC RATINGS<br />

<strong>Acoustic</strong> ratings in this <strong>Guide</strong> have been prepared by<br />

Marshall Day <strong>Acoustic</strong>s Pty Ltd. <strong>Acoustic</strong> ratings have<br />

been developed based upon laboratory test data for<br />

<strong>BGC</strong> wall <strong>and</strong> floor systems, other available laboratory<br />

data for comparable constructions <strong>and</strong> calculations<br />

based on theoretical models. Ratings are expected<br />

to be accurate to within ± 2.5 Rw.<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

02 / ACOUSTIC INFORMATION<br />

21


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 02 / ACOUSTIC INFORMATION<br />

22<br />

GLOSSARY OF<br />

ACOUSTIC TERMS<br />

dB<br />

NOISE<br />

SOUND INSULATION or<br />

SOUND REDUCTION<br />

R w<br />

D nT,w<br />

C tr<br />

R w +C tr<br />

D nT,w +C tr<br />

FLANKING<br />

STRUCTURE-BORNE<br />

TRANSMISSION<br />

Decibel. The unit of sound level.<br />

Unwanted sound.<br />

When sound hits a surface, some of the sound energy travels<br />

through the material. ‘Sound insulation or sound reduction’ refers to<br />

ability of a material to stop sound travelling through it.<br />

Weighted sound reduction index.<br />

A single number rating of the sound insulation performance of<br />

a specific building element such as a wall or floor.<br />

R w is measured in a laboratory.<br />

Weighted st<strong>and</strong>ardised level difference.<br />

A single number rating of the sound level difference between two rooms.<br />

D nT,w is typically used to measure on-site sound insulation performance<br />

of building elements such as a walls or floors.<br />

The on-site D nT,w value is typically about 5 points less than the<br />

laboratory R w value.<br />

C tr is a sound insulation adjustment, commonly used with R w <strong>and</strong> D nT,w .<br />

C tr adjusts for low frequency noise, such as noise from trucks <strong>and</strong><br />

subwoofers. C tr values typically range from about -4 to about -12.<br />

The combined value of Weighted sound reduction index R w + Spectrum<br />

adaptation term C tr .<br />

A single number rating of the sound insulation performance of a building<br />

element with the C tr correction included. R w +C tr values are measured<br />

in the laboratory <strong>and</strong> are lower than R w values.<br />

The combined value of Weighted st<strong>and</strong>ardised level difference D nT,w<br />

+ spectrum adaptation term C tr .<br />

A single number rating of the sound level difference between two rooms<br />

with the C tr correction included. D nT,w +C tr is used to measure on-site<br />

sound insulation performance of building elements such as a walls or<br />

floors. D nT,w +C tr values are lower than D nT,w values.<br />

Transmission of sound energy through paths adjacent to the building<br />

element being considered. For example, sound may be transmitted<br />

around a wall by travelling up into the ceiling space <strong>and</strong> then down<br />

into the adjacent room.<br />

Transmission of sound energy as vibrations inside the structure<br />

of a building.


INTRODUCTION<br />

<strong>BGC</strong> fire-rated systems consist of single or multiple<br />

layers of <strong>BGC</strong> <strong>Fire</strong>board sheets, screw-fixed to steel<br />

framing <strong>and</strong> nail or screw fixed to timber stud framing.<br />

<strong>BGC</strong> <strong>Fire</strong>board is manufactured to the requirements<br />

of Australian St<strong>and</strong>ards AS/NZS 2588:1998 -<br />

“Gypsum plasterboard” <strong>and</strong> must be installed in<br />

accordance with the Australian St<strong>and</strong>ards AS/NZS<br />

2589:2007 Gypsum linings - Application <strong>and</strong> Finishing.<br />

<strong>BGC</strong> fire rated systems have been tested<br />

according to AS/NZS 3837: 1998 <strong>and</strong> AS/NZS<br />

1530.4, by NATA accredited testing laboratories.<br />

<strong>BGC</strong> <strong>Fire</strong>board has a light-pink facing liner board <strong>and</strong><br />

<strong>BGC</strong> Wet Area <strong>Fire</strong>board has a blue/grey facing liner<br />

board for easy identification <strong>and</strong> is available in 13mm<br />

<strong>and</strong> 16mm thicknesses with recessed edges, ready<br />

for taping <strong>and</strong> jointing with proprietary<br />

jointing materials.<br />

EARLY FIRE HAZARD INDICES<br />

<strong>BGC</strong> <strong>Fire</strong>board complies with the Building Code of<br />

Australia (BCA) Material Group Number Classification<br />

<strong>and</strong> Deemed to Satisfy Provisions, as determined<br />

by AS/NZS 3837: 1998 tests.<br />

• Material Classification: Group 1.<br />

(BCA) Specification A2.4)<br />

• Suitability as Wall <strong>and</strong> Ceiling Lining In <strong>Fire</strong>-Isolated<br />

Exits, Public Corridors, Specified <strong>and</strong> Other Areas.<br />

(BCA Specification C1.10a Section 3(c) <strong>and</strong> Table 2:<br />

Wall <strong>and</strong> Ceiling Linings Material Groups Permitted.<br />

• CSIRO BCE Certificate No 482<br />

APPLICATION<br />

<strong>BGC</strong> <strong>Fire</strong>board systems are suitable for industrial,<br />

commercial <strong>and</strong> residential applications, both in<br />

the new construction <strong>and</strong> renovation sectors.<br />

Load bearing, non-load bearing walls <strong>and</strong> partitions<br />

can be clad with single or multiple layers of <strong>BGC</strong><br />

<strong>Fire</strong>board, with or without cavity infill insulation,<br />

to achieve the required results for fire resistance:<br />

FRL <strong>and</strong> acoustic properties: RW.<br />

<strong>BGC</strong> FIRE-RESISTANT (FR)<br />

PLASTERBOARD PARTITION SYSTEMS<br />

NON-LOAD BEARING WALLS<br />

The maximum wall heights for non-load bearing<br />

fire rated walls, in this Installation <strong>Guide</strong> are for<br />

laterally loaded walls of 0.25 kPa <strong>and</strong> 0.35 kPa,<br />

as set out in the Rondo Tables on page 11.<br />

The maximum stud height is based H/240 or<br />

30mm maximum deflection, to comply with<br />

BCA 2004 Specification 1.8 Clause 3.4.<br />

LOAD BEARING WALLS<br />

Load bearing walls in this Installation <strong>Guide</strong> must<br />

be designed <strong>and</strong> constructed in accordance with<br />

AS 1684 <strong>and</strong> AS 1720, for timber construction<br />

<strong>and</strong> AS/NZS 4600 <strong>and</strong> AS 3623 for light-weight<br />

Cold-Formed-Steel (CFS) construction.<br />

Load bearing walls must be designed <strong>and</strong> constructed<br />

to take all loads without any cladding or lining.<br />

INSTALLATION<br />

Installation is to be in accordance with AS/NZS<br />

2589:2007 Gypsum linings - Application <strong>and</strong><br />

Finishing <strong>and</strong> as set out in this manual.<br />

All fire rated plasterboard must be mechanically<br />

fastener fixed to steel or timber framing.<br />

Stud adhesive must not be used.<br />

For multiple layered systems all joints must be<br />

staggered <strong>and</strong> butt joints in the outer layer may<br />

be reinforced with laminating screws.<br />

All perimeter gaps <strong>and</strong> penetrations must be<br />

fully sealed with an AS/NZS approved fire rated<br />

mastic sealant, to attain the required FRL<br />

<strong>and</strong> RW ratings.<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

03 / FIRE INFORMATION<br />

23


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

FIRE RESISTANCE TERMS<br />

AND DEFINITIONS<br />

FIRE RESISTANCE LEVEL (FRL)<br />

The nominal grading period, in minutes, that<br />

is determined by subjecting a specimen to the<br />

st<strong>and</strong>ard time temperature curve regime as set<br />

out in AS1530.4.<br />

This is to specify—<br />

(a) Structural adequacy<br />

(b) Integrity<br />

(c) Insulation<br />

These are expressed in that order.<br />

Refer to the example below<br />

INSULATION<br />

The ability of an element of construction to maintain<br />

a temperature on the surface that is not exposed to<br />

the furnace, below the limits specified, when tested<br />

in accordance with AS1530.4.<br />

Eg: 60/60/60<br />

This means that during a fire test, the system did<br />

not fail for 60 minutes for each of the criteria.<br />

Ensure fasteners used to fix top <strong>and</strong> bottom track are<br />

appropriate for the Uniform Distributed Loads (UDL)<br />

on walls.<br />

03 / FIRE INFORMATION 24<br />

60/60/60. This indicates that it is a loadbearing<br />

system as it has a figure (60) in the first area<br />

(Structural adequacy)<br />

-/60/60. This indicates that it is a non loadbearing<br />

system as it has no figure (-) in the first area<br />

(Structural adequacy)<br />

The definitions as set out in the St<strong>and</strong>ard<br />

are below:<br />

STRUCTURAL ADEQUACY<br />

The ability of a load-bearing element of construction<br />

to support a load when tested in accordance<br />

with AS1530.4.<br />

Eg: 60/60/60<br />

INTEGRITY<br />

The ability of an element of construction to resist<br />

the passage of flames <strong>and</strong> hot gases from one<br />

space to another, when tested in accordance<br />

with AS1530.4.<br />

Eg: 60/60/60<br />

VERTICAL - TEMP CELSIUS/ HORIZONTAL - TIME MINS<br />

1400<br />

1200<br />

1000<br />

800<br />

600<br />

400<br />

200<br />

At 600mm fastener centres <strong>and</strong> a UDL of 0.25kPa,<br />

the fasteners must withst<strong>and</strong> a shear load of 0.75kN.<br />

At 600mm fastener centres <strong>and</strong> a UDL of 0.35kPa,<br />

the fasteners must withst<strong>and</strong> a shear load of 1.1kN.<br />

Below is the st<strong>and</strong>ard time vs temperature table<br />

which is represented in the STANDARD TIME<br />

VS TEMPERATURE CURVE.<br />

This shows the rise in temperature vs the<br />

associated time.<br />

As indicated, in 5 minutes the temperature in<br />

the test facility has risen to 576 degrees Celsius,<br />

in 15 minutes 738 degrees Celsius <strong>and</strong> 90 minutes<br />

over 1,000 degrees Celsius <strong>and</strong> so on.<br />

Where a wall or ceiling is required to meet the<br />

various requirements under the BCA it is the job of<br />

the <strong>Fire</strong>board <strong>and</strong> the framing to prevent the flames,<br />

smoke <strong>and</strong> temperature from getting through to<br />

the other side.<br />

For example, where there is a wall required to<br />

achieve a -/120/120 system number SO21 shows<br />

2 layers of 13mm <strong>Fire</strong>board both sides of a metal<br />

stud. Effectively overall there is 52mm of fire rated<br />

plasterboard <strong>and</strong> framing to stop a peak of over<br />

1,000 degrees of heat reaching through to the<br />

other side for a period of 2 hours.<br />

0<br />

0 100 200 300 400<br />

Time Mins 0 5 10 15 30 60 90 120 180 240 360<br />

Temp Celsius 20 576 679 738 841 945 1006 1049 1110 1153 1213


CONTROL JOINTS<br />

A joint between or within discrete elements of<br />

construction, which allows for relative movement<br />

of the elements.<br />

Control joints can allow for a degree of building<br />

movement which can result from such things<br />

as moisture, loads, structural movement <strong>and</strong><br />

foundation settlement etc. Cracks in plasterboard<br />

<strong>and</strong> plasterboard joints should be eliminated by using<br />

control joints <strong>and</strong> the correct installation techniques.<br />

Control joints must be installed in plasterboard<br />

walls <strong>and</strong> ceilings at:<br />

• Maximum 12 metre intervals<br />

• Control joints in the structure<br />

• Any change in the substrate material<br />

• Junctions of dissimilar structural products<br />

• When long runs of plasterboard meet at right<br />

angle (change of direction)<br />

Distance between control joints may need to<br />

be minimised to less than 12 metres due to on<br />

site conditions such as humidity or temperature<br />

variations or where ever excessive structural<br />

movement is likely to occur.<br />

ACCEPTABLE VARIATIONS TO<br />

FIRE RATED SYSTEMS<br />

<strong>Fire</strong> rated systems must be built according to<br />

<strong>BGC</strong> installation instructions. However, there<br />

are some variations allowed that will not degrade<br />

the performance of the system:<br />

• Increasing the width of the cavity (between stud<br />

walls in a double stud wall system)<br />

• Increasing the stud size or the metal thickness<br />

• Adding noggings to support fixtures or services<br />

• Decreasing stud spacing<br />

(increasing amount of studs)<br />

• Additional fasteners<br />

• Adding non-combustible layers to a system up<br />

to a weight of 20kg/m2 <strong>and</strong> no thicker than 25mm.<br />

This includes fibre cement board up to 9mm thick<br />

<strong>and</strong> plasterboard up to 25mm thick. For load<br />

bearing walls, the load per stud must include<br />

the extra lining.<br />

<strong>BGC</strong> FIRE-RESISTANT (FR)<br />

PLASTERBOARD PARTITION SYSTEMS<br />

MODIFICATIONS TO FIRE<br />

RATED SYSTEMS<br />

<strong>Fire</strong> rated systems may be modified by the installation<br />

of the following examples but not limited to these:<br />

• <strong>Fire</strong> rated inspection hatches<br />

• <strong>Fire</strong> rated power points<br />

• <strong>Fire</strong> rated light fittings<br />

• <strong>Fire</strong> rated doors<br />

It is the responsibility of the manufacturer of additional<br />

components in a fire system to ensure that the fire<br />

<strong>and</strong> acoustic properties of the plasterboard system<br />

are maintained. Any modification not covered in<br />

this manual must be according to the relevant<br />

manufacturer’s instructions.<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

03 / FIRE INFORMATION<br />

25


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 03 / FIRE INFORMATION<br />

26


STEEL FRAME INTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 10mm <strong>BGC</strong> Plasterboard<br />

Side 2 1 x 10mm <strong>BGC</strong> Plasterboard<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> Plasterboard<br />

Side 2 1 x 13mm <strong>BGC</strong> Plasterboard<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 13mm <strong>BGC</strong> Plasterboard<br />

Side 2 1 x 13mm <strong>BGC</strong> Plasterboard<br />

S001<br />

51 64 76 92 150<br />

Rw/Rw+Ctr<br />

30/25 31/25 31/26 32/26 33/27<br />

38/29 39/29 40/30 41/31 43/34<br />

38/29 40/30 40/30 42/31 44/34<br />

71 84 96 112 170<br />

S002<br />

51 64 76 92 150<br />

Rw/Rw+Ctr<br />

33/28 34/28 34/28 35/29 37/31<br />

41/31 42/32 43/32 44/33 46/37<br />

42/31 43/32 44/32 45/34 47/37<br />

77 90 102 118 176<br />

S003<br />

51 64 76 92 150<br />

Rw/Rw+Ctr<br />

38/32 38/32 39/32 40/33 42/34<br />

45/34 46/34 47/37 49/40 49/41<br />

45/34 46/34 48/37 49/40 49/42<br />

90 103 115 131 189<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

04 / STEEL FRAME INFORMATION<br />

27


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 13mm <strong>BGC</strong> Plasterboard<br />

Side 2 2 x 13mm <strong>BGC</strong> Plasterboard<br />

S005<br />

04 / STEEL FRAME INFORMATION 28<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

STUD DEPTH mm<br />

51 64 76 92 150<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

41/34 42/33 43/37 44/37 46/38<br />

9kg - 50mm Polyester<br />

49/38 50/41 52/43 53/45 55/48<br />

30kg - 75mm Polyester<br />

49/38 50/41 53/43 54/46 55/48<br />

WALL THICKNESS mm<br />

103 116 128 144 202<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 10mm <strong>BGC</strong> Soundboard TM<br />

Side 2 1 x 10mm <strong>BGC</strong> Soundboard TM<br />

S006<br />

STUD DEPTH mm<br />

51 64 76 92 150<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

33/28 35/29 35/29 36/29 38/31<br />

9kg - 50mm Polyester<br />

41/31 42/32 44/33 44/34 47/38<br />

30kg - 75mm Polyester<br />

41/31 43/32 44/33 45/34 48/39<br />

WALL THICKNESS mm<br />

71 84 96 112 170<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> Soundboard TM<br />

Side 2 1 x 13mm <strong>BGC</strong> Soundboard TM<br />

S007<br />

STUD DEPTH mm<br />

51 64 76 92 150<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

36/31<br />

44/33<br />

44/33<br />

77<br />

37/31<br />

45/34<br />

45/35<br />

90<br />

Rw/Rw+Ctr<br />

38/32<br />

46/37<br />

46/38<br />

102<br />

39/33<br />

46/38<br />

47/38<br />

118<br />

41/34<br />

48/42<br />

49/43<br />

176


FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / 60 / 60<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 10mm <strong>BGC</strong> Soundboard TM<br />

Side 2 1 x 10mm <strong>BGC</strong> WR Plasterboard<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 10mm <strong>BGC</strong> Soundboard TM<br />

Side 2 2 x 10mm <strong>BGC</strong> Soundboard TM<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

PREVIOUSLY <strong>BGC</strong>001<br />

S009<br />

51 64 76 92 150<br />

Rw/Rw+Ctr<br />

38/32 38/32 39/32 40/33 42/34<br />

44/34 46/34 47/36 48/39 49/41<br />

45/34 47/34 47/36 49/39 49/41<br />

81 94 106 122 180<br />

S010<br />

51 64 76 92 150<br />

Rw/Rw+Ctr<br />

42/34 43/36 44/37 44/37 46/38<br />

50/40 52/41 53/43 54/46 55/48<br />

50/40 52/42 53/44 54/46 55/49<br />

91 104 116 132 190<br />

S011<br />

51 64 76 92 150<br />

Rw/Rw+Ctr<br />

34/29 35/29 36/30 37/31 39/33<br />

42/32 43/32 44/33 45/36 47/40<br />

42/32 44/33 44/34 46/37 48/41<br />

77 90 102 118 176<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

04 / STEEL FRAME INFORMATION<br />

29


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

1 x 10mm <strong>BGC</strong> Plasterboard<br />

Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

S012<br />

04 / STEEL FRAME INFORMATION 30<br />

FRL<br />

- / 60 / 60<br />

FRL<br />

- / 60 / 60<br />

FRL<br />

- / 60 / 60<br />

60 / 60 / 60<br />

STUD DEPTH mm 51 64 76 92 150<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

38/33 39/33 40/33 41/34 43/35<br />

9kg - 50mm Polyester<br />

46/34 47/36 48/39 49/39 50/42<br />

30kg - 75mm Polyester<br />

46/34 48/36 49/39 49/39 50/42<br />

WALL THICKNESS mm<br />

87 100 112 128 186<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

S018<br />

STUD DEPTH mm 51 64 76 92 150<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

39/33 40/33 40/34 41/35 43/37<br />

9kg - 50mm Polyester<br />

47/35 48/38 49/41 50/41 52/44<br />

30kg - 75mm Polyester<br />

48/35 49/39 49/41 51/42 52/45<br />

WALL THICKNESS mm<br />

90 103 115 131 189<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

PREVIOUSLY <strong>BGC</strong>003<br />

S019<br />

STUD DEPTH mm 51 64 76 92 150<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

36/31 37/31 38/32 39/33 41/34<br />

9kg - 50mm Polyester<br />

44/33 45/34 46/37 46/38 48/42<br />

30kg - 75mm Polyester<br />

44/33 45/35 46/38 47/38 49/43<br />

WALL THICKNESS mm<br />

83 96 108 124 182


FRL<br />

- / 120 / 120<br />

FRL<br />

- / 120 / 120<br />

90 / 90 / 90<br />

FRL<br />

-/120/120<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

PREVIOUSLY <strong>BGC</strong>002<br />

S021<br />

STUD DEPTH mm 51 64 76 92 150<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

PREVIOUSLY <strong>BGC</strong>004<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Rw/Rw+Ctr<br />

43/36 44/38 45/39 46/39 48/41<br />

50/42 52/43 54/46 54/47 56/49<br />

50/42 52/44 54/47 55/48 56/49<br />

103 116 128 144 202<br />

S023<br />

STUD DEPTH mm 51 64 76 92 150<br />

Rw/Rw+Ctr<br />

45/38 47/40 47/39 48/40 50/42<br />

53/43 54/46 55/47 55/48 56/49<br />

54/44 55/47 55/47 56/49 56/49<br />

115 128 140 156 214<br />

S025<br />

STUD DEPTH mm 51 64 76 92 150<br />

Rw/Rw+Ctr<br />

47/41 48/41 49/42 50/43 53/45<br />

57/49 57/50 58/51 58/52 59/54<br />

57/49 58/51 58/52 58/53 59/55<br />

129 142 154 170 228<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

04 / STEEL FRAME INFORMATION<br />

31


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

S026<br />

04 / STEEL FRAME INFORMATION 32<br />

FRL<br />

- / 180 / 180<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

STUD DEPTH mm<br />

51 64 76 92 150<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

50/43 51/44 51/44 52/45 54/46<br />

9kg - 50mm Polyester<br />

58/49 58/51 58/53 59/54 59/56<br />

30kg - 75mm Polyester<br />

58/49 58/52 59/54 59/54 59/56<br />

WALL THICKNESS mm<br />

147 160 172 188 246<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

S027<br />

STUD DEPTH mm<br />

51 64 76 92 150<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

32/26 33/26 33/26 33/27 35/28<br />

9kg - 50mm Polyester<br />

41/31 41/31 43/32 44/32 46/35<br />

30kg - 75mm Polyester<br />

41/31 42/31 43/32 44/32 46/35<br />

WALL THICKNESS mm<br />

63 76 88 104 162<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 9mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM<br />

S028<br />

STUD DEPTH mm<br />

51 64 76 92 150<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

39/32<br />

45/33<br />

46/34<br />

69<br />

40/33<br />

47/35<br />

47/35<br />

82<br />

Rw/Rw+Ctr<br />

41/33<br />

48/37<br />

49/37<br />

94<br />

41/34<br />

49/38<br />

49/38<br />

110<br />

42/34<br />

49/42<br />

49/43<br />

168


FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 12mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 12mm <strong>BGC</strong> Duraliner TM<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 10mm <strong>BGC</strong> Soundboard TM<br />

Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> Plasterboard<br />

Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

S029<br />

51 64 76 92 150<br />

Rw/Rw+Ctr<br />

40/33 40/33 41/35 43/36 44/37<br />

48/36 49/40 49/40 52/44 54/47<br />

48/37 49/40 49/40 53/44 54/47<br />

75 88 100 116 174<br />

S031<br />

51 64 76 92 150<br />

Rw/Rw+Ctr<br />

34/28 35/29 35/28 36/29 38/31<br />

41/31 42/32 44/32 44/33 46/36<br />

42/31 43/32 44/32 45/33 47/37<br />

67 80 92 108 166<br />

S033<br />

51 64 76 92 150<br />

Rw/Rw+Ctr<br />

34/28 35/28 35/28 36/29 38/31<br />

41/31 42/31 43/32 44/33 46/36<br />

41/31 42/32 44/32 45/33 47/37<br />

70 83 95 111 169<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

04 / STEEL FRAME INFORMATION<br />

33


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 04 / STEEL FRAME INFORMATION<br />

34<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / 60 / 60<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> Plasterboard<br />

Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

51 64 76 92 150<br />

Rw/Rw+Ctr<br />

36/30 36/30 37/31 38/31 41/34<br />

42/32 44/33 45/34 46/36 49/40<br />

43/32 45/33 46/34 47/37 49/40<br />

73 86 98 114 172<br />

51 64 76 92 150<br />

Rw/Rw+Ctr<br />

34/28 35/28 35/28 36/29 38/31<br />

41/31 43/32 45/33 46/35 49/39<br />

42/31 44/33 45/33 46/35 49/40<br />

70 83 95 111 169<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />

1 x 9mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />

1 x 9mm <strong>BGC</strong> Duraliner TM<br />

S034<br />

S035<br />

S041<br />

51 64 76 92 150<br />

Rw/Rw+Ctr<br />

45/38 47/40 47/39 48/40 50/42<br />

53/43 54/46 55/47 55/48 56/49<br />

54/44 55/47 55/47 56/49 56/49<br />

73 86 98 114 172


FRL<br />

120 / 120 / 120<br />

FRL<br />

- / 180 / 180<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 9mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

PREVIOUSLY <strong>BGC</strong> DL001<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 16mm Wet Area <strong>Fire</strong>board<br />

Side 2 2 x 16mm Wet Area <strong>Fire</strong>board<br />

S043<br />

51 64 76 92 150<br />

Rw/Rw+Ctr<br />

45/38 47/40 47/39 48/40 50/42<br />

53/43 54/46 55/47 55/48 56/49<br />

54/44 55/47 55/47 56/49 56/49<br />

73 86 98 114 172<br />

S044<br />

51 64 76 92 150<br />

Rw/Rw+Ctr<br />

45/38 47/40 47/39 48/40 50/42<br />

53/43 54/46 55/47 55/48 56/49<br />

54/44 55/47 55/47 56/49 56/49<br />

73 86 98 114 172<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

04 / STEEL FRAME INFORMATION<br />

35


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 04 / STEEL FRAME INFORMATION<br />

36<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

FRL<br />

- / 120 / 120<br />

120 / 120 / 120<br />

FRL<br />

- / 60 / 60<br />

FRL<br />

- / 120 / 120<br />

120 / 120 / 120<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1<br />

Side 2 3 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

STUD DEPTH mm 51 64 76 92 150<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1<br />

Side 2 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

STUD DEPTH mm 51 64 76 92 150<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1<br />

Side 2 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

S045<br />

Rw/Rw+Ctr<br />

38/36 - - - -<br />

- - - - -<br />

- - - - -<br />

99 112 124 140 198<br />

S046<br />

Rw/Rw+Ctr<br />

35/32 - - - -<br />

- - - - -<br />

- - - - -<br />

83 96 108 124 182<br />

S048<br />

STUD DEPTH mm 51 64 76 92 150<br />

Rw/Rw+Ctr<br />

38/36 - - - -<br />

- - - - -<br />

- - - - -<br />

99 112 124 140 198


FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

STAGGERED STUD<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 10mm <strong>BGC</strong> Plasterboard<br />

Side 2 1 x 10mm <strong>BGC</strong> Plasterboard<br />

CAVITY WIDTH mm 76 92 150<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

33/27 33/27 34/28<br />

42/32 43/33 46/36<br />

42/32 44/33 47/37<br />

96 112 170<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> Plasterboard<br />

Side 2 1 x 13mm <strong>BGC</strong> Plasterboard<br />

CAVITY WIDTH mm 76 92 150<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

36/30 37/31 39/33<br />

46/34 47/36 49/38<br />

46/34 47/36 49/38<br />

102 118 176<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 10mm <strong>BGC</strong> Soundboard TM<br />

Side 2 1 x 10mm <strong>BGC</strong> Soundboard TM<br />

CAVITY WIDTH mm 76 92 150<br />

Rw/Rw+Ctr<br />

SS001<br />

SS002<br />

SS006<br />

36/30 37/30 39/32<br />

46/35 47/36 49/38<br />

47/35 48/36 49/38<br />

96 112 170<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

04 / STEEL FRAME INFORMATION<br />

37


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

STAGGERED STUD<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> Soundboard TM<br />

Side 2 1 x 13mm <strong>BGC</strong> Soundboard TM<br />

SS007<br />

04 / STEEL FRAME INFORMATION 38<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / 60 / 60<br />

CAVITY WIDTH mm 76 92 150<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

38/32 39/33 41/34<br />

9kg - 50mm Polyester<br />

48/38 49/39 52/44<br />

30kg - 75mm Polyester<br />

49/38 50/39 53/45<br />

WALL THICKNESS mm<br />

102 118 176<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 10mm <strong>BGC</strong> Soundboard TM<br />

Side 2 2 x 10mm <strong>BGC</strong> Soundboard TM<br />

SS010<br />

CAVITY WIDTH mm 76 92 150<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

46/39 46/39 49/41<br />

9kg - 50mm Polyester<br />

54/44 56/46 58/49<br />

30kg - 75mm Polyester<br />

55/44 57/47 59/50<br />

WALL THICKNESS mm<br />

116 132 190<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

SS011<br />

CAVITY WIDTH mm 76 92 150<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

38/32 39/33 41/35<br />

9kg - 50mm Polyester<br />

47/36 49/38 50/42<br />

30kg - 75mm Polyester<br />

48/36 49/38 51/42<br />

WALL THICKNESS mm<br />

102 118 176


FRL<br />

- / 60 / 60<br />

FRL<br />

- / 60 / 60<br />

FRL<br />

- / 60 / 60<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

STAGGERED STUD<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

1 x 13mm <strong>BGC</strong> Plasterboard<br />

Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY WIDTH mm 76 92 150<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY WIDTH mm 76 92 150<br />

Rw/Rw+Ctr<br />

41/35 43/37 45/38<br />

52/43 53/43 55/47<br />

53/43 54/43 57/48<br />

115 131 189<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY WIDTH mm 76 92 150<br />

Rw/Rw+Ctr<br />

SS014<br />

40/33 42/36 44/37<br />

50/42 52/42 55/46<br />

50/42 54/42 56/47<br />

115 131 189<br />

SS018<br />

SS019<br />

38/32 39/33 41/34<br />

48/38 49/39 52/44<br />

49/38 50/39 53/45<br />

108 124 182<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

04 / STEEL FRAME INFORMATION<br />

39


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 04 / STEEL FRAME INFORMATION<br />

40<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

STAGGERED STUD<br />

FRL<br />

- / 60 / 60<br />

FRL<br />

- / 120 / 120<br />

FRL<br />

- / 120 / 120<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY WIDTH mm 76 92 150<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

SS020<br />

43/36 44/38 46/39<br />

53/42 54/45 56/48<br />

54/43 55/45 57/49<br />

121 137 195<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY WIDTH mm 76 92 150<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

46/40 47/40 50/42<br />

56/46 57/48 59/52<br />

57/46 58/49 60/52<br />

128 144 202<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY WIDTH mm 76 92 150<br />

Rw/Rw+Ctr<br />

SS021<br />

SS023<br />

47/40 48/41 51/43<br />

57/48 58/49 61/54<br />

58/49 59/50 61/54<br />

140 156 214


FRL<br />

- / 180 / 180<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

STAGGERED STUD<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY WIDTH mm 76 92 150<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

SS026<br />

50/42 51/43 54/45<br />

60/52 61/53 62/56<br />

61/53 61/54 62/57<br />

172 188 246<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 9mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM<br />

CAVITY WIDTH mm 76 92 150<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

SS028<br />

39/31 39/32 41/33<br />

48/37 49/37 52/42<br />

49/37 50/38 54/43<br />

94 110 168<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 10mm <strong>BGC</strong> Soundboard TM<br />

Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

CAVITY WIDTH mm 76 92 150<br />

Rw/Rw+Ctr<br />

SS032<br />

39/32 39/32 41/33<br />

47/36 49/39 52/43<br />

49/37 50/39 54/43<br />

102 118 176<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

04 / STEEL FRAME INFORMATION<br />

41


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 04 / STEEL FRAME INFORMATION<br />

42<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

STAGGERED STUD<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> Plasterboard<br />

Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

CAVITY WIDTH mm 76 92 150<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

35/28 36/29 38/31<br />

45/34 46/35 49/38<br />

46/34 47/35 49/38<br />

95 111 169<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> Plasterboard<br />

Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM<br />

CAVITY WIDTH mm 76 92 150<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

CAVITY WIDTH mm 76 92 150<br />

Rw/Rw+Ctr<br />

SS033<br />

SS034<br />

38/32 39/32 42/35<br />

47/35 49/38 50/42<br />

48/36 49/38 51/40<br />

98 114 172<br />

SS035<br />

36/29 37/30 39/32<br />

46/34 47/36 49/38<br />

47/34 48/36 49/38<br />

95 111 169


FRL<br />

- / - / -<br />

FRL<br />

- / 60 / 60<br />

FRL<br />

120 / 120 / 120<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

STAGGERED STUD<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />

1 x 9mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />

1 x 9mm <strong>BGC</strong> Duraliner TM<br />

CAVITY WIDTH mm 76 92 150<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 9mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY WIDTH mm 76 92 150<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

47/39 48/40 51/43<br />

57/47 58/49 60/52<br />

58/48 59/50 61/53<br />

98 114 172<br />

STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 9mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

PREVIOUSLY <strong>BGC</strong> DL001<br />

Rw/Rw+Ctr<br />

CAVITY WIDTH mm 76 92 150<br />

Rw/Rw+Ctr<br />

SS036<br />

39/31 39/32 41/33<br />

48/37 49/37 52/42<br />

49/38 50/38 53/43<br />

101 117 175<br />

SS041<br />

SS043<br />

47/39 48/40 51/43<br />

57/47 58/49 60/52<br />

58/48 59/50 61/53<br />

98 114 172<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

04 / STEEL FRAME INFORMATION 43


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

DOUBLE STUD<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 10mm <strong>BGC</strong> Plasterboard<br />

Side 2 1 x 10mm <strong>BGC</strong> Plasterboard<br />

SD001<br />

04 / STEEL FRAME INFORMATION 44<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

CAVITY WIDTH mm<br />

148 172 204 320<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

34/28 34/28 35/28 36/28<br />

9kg – 50mm Polyester – 1 side<br />

44/33 45/35 46/37 46/39<br />

9kg – 50mm Polyester – 2 sides<br />

46/35 47/37 48/39 48/41<br />

30kg – 75mm Polyester – 1 side<br />

47/36 49/38 49/40 49/41<br />

30kg – 75mm Polyester – 2 sides<br />

49/36 49/38 49/39 50/42<br />

WALL THICKNESS mm<br />

168 192 224 340<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> Plasterboard<br />

Side 2 1 x 13mm <strong>BGC</strong> Plasterboard<br />

SD002<br />

CAVITY WIDTH mm<br />

148 172 204 320<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

39/33 39/32 40/33 42/34<br />

9kg – 50mm Polyester – 1 side<br />

51/42 52/43 52/44 52/46<br />

9kg – 50mm Polyester – 2 sides<br />

53/43 54/44 54/46 55/48<br />

30kg – 75mm Polyester – 1 side<br />

54/43 54/44 55/46 56/48<br />

30kg – 75mm Polyester – 2 sides<br />

56/45 57/45 57/47 58/49<br />

WALL THICKNESS mm<br />

174 198 230 346<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 10mm <strong>BGC</strong> Soundboard TM<br />

Side 2 1 x 10mm <strong>BGC</strong> Soundboard TM<br />

SD006<br />

CAVITY WIDTH mm<br />

148 172 204 320<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

39/32 39/33 40/33 42/33<br />

9kg – 50mm Polyester – 1 side<br />

51/41 52/43 52/44 52/46<br />

9kg – 50mm Polyester – 2 sides<br />

53/43 54/45 55/46 55/49<br />

30kg – 75mm Polyester – 1 side<br />

54/43 55/45 56/46 56/49<br />

30kg – 75mm Polyester – 2 sides<br />

56/44 57/46 57/47 58/49<br />

WALL THICKNESS mm<br />

168 192 224 340


FRL<br />

- / - / -<br />

FRL<br />

- / 60 / 60<br />

FRL<br />

60 / 60 / 60<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

DOUBLE STUD<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> Soundboard TM<br />

Side 2 1 x 13mm <strong>BGC</strong> Soundboard TM<br />

148 172 204 320<br />

Rw/Rw+Ctr<br />

42/35 42/35 43/36 46/37<br />

54/45 55/47 55/48 56/49<br />

56/45 57/48 57/49 58/49<br />

57/46 57/48 58/49 59/50<br />

59/48 60/49 60/49 61/50<br />

174 198 230 346<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

SD007<br />

SD011<br />

148 172 204 320<br />

Rw/Rw+Ctr<br />

40/34 41/34 42/35 43/35<br />

52/43 52/45 53/45 53/48<br />

54/45 54/46 55/47 55/49<br />

55/46 56/47 57/48 57/49<br />

57/46 58/47 58/48 59/49<br />

174 198 230 346<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />

1 x 10mm <strong>BGC</strong> Plasterboard<br />

Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />

1 x 10mm <strong>BGC</strong> Plasterboard<br />

SD016<br />

148 172 204 320<br />

Rw/Rw+Ctr<br />

46/39 47/39 48/39 49/40<br />

58/48 59/49 59/49 59/50<br />

60/51 61/52 61/53 62/53<br />

61/51 62/52 62/53 63/54<br />

63/52 65/53 65/54 66/55<br />

200 224 256 372<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

04 / STEEL FRAME INFORMATION<br />

45


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 04 / STEEL FRAME INFORMATION<br />

46<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

DOUBLE STUD<br />

FRL<br />

- / 60 / 60<br />

60 / 60 / 60<br />

FRL<br />

- / 120 / 120<br />

90 / 90 / 90<br />

FRL<br />

- / 120 / 120<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

SD019<br />

148 172 204 320<br />

Rw/Rw+Ctr<br />

41/34 41/34 42/35 45/36<br />

53/45 54/46 54/47 55/49<br />

55/46 56/45 56/49 57/51<br />

56/46 56/47 57/49 58/51<br />

58/48 59/49 60/50 61/52<br />

180 204 236 352<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

SD021<br />

148 172 204 320<br />

Rw/Rw+Ctr<br />

48/40 49/41 50/41 53/44<br />

60/51 60/52 61/53 61/55<br />

62/52 62/53 63/55 63/57<br />

63/53 64/54 65/56 65/58<br />

65/58 66/58 67/58 68/60<br />

200 224 256 372<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

SD023<br />

148 172 204 320<br />

Rw/Rw+Ctr<br />

48/40 49/41 51/42 54/44<br />

60/52 61/53 61/54 62/56<br />

62/53 63/54 63/55 64/58<br />

63/53 64/54 64/56 65/58<br />

65/58 66/58 66/58 67/60<br />

212 236 268 384


FRL<br />

- / 60 / 60<br />

FRL<br />

- / 120 / 120<br />

FRL<br />

- / 180 / 180<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

DOUBLE STUD<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

148 172 204 320<br />

Rw/Rw+Ctr<br />

45/38 46/39 47/39 49/40<br />

57/48 57/49 58/49 59/50<br />

59/50 59/51 60/52 61/53<br />

60/50 61/51 62/53 63/54<br />

62/54 63/54 64/54 65/55<br />

187 211 243 359<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

SD024<br />

SD025<br />

148 172 204 320<br />

Rw/Rw+Ctr<br />

54/45 55/46 56/47 59/49<br />

67/58 67/59 68/60 68/62<br />

68/58 68/59 69/61 69/63<br />

69/58 69/60 70/61 71/64<br />

71/59 71/60 72/62 73/65<br />

226 250 282 398<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

SD026<br />

148 172 204 320<br />

Rw/Rw+Ctr<br />

55/46 56/46 57/47 60/49<br />

67/59 68/60 68/61 69/63<br />

69/60 70/61 70/63 71/65<br />

70/60 71/61 71/63 72/65<br />

72/61 73/62 73/63 74/67<br />

244 268 300 416<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

04 / STEEL FRAME INFORMATION<br />

47


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 04 / STEEL FRAME INFORMATION<br />

48<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

DOUBLE STUD<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / 60 / 60<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

148 172 204 320<br />

Rw/Rw+Ctr<br />

38/31 39/32 39/32 41/33<br />

50/40 51/41 51/43 52/45<br />

52/41 53/43 53/44 54/46<br />

53/42 54/43 54/45 55/47<br />

55/43 57/45 57/47 58/49<br />

160 184 216 332<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 9mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM<br />

148 172 204 320<br />

Rw/Rw+Ctr<br />

42/35 43/35 44/36 46/38<br />

54/44 55/45 55/47 56/49<br />

56/46 57/47 57/48 58/49<br />

57/46 58/48 58/49 59/49<br />

59/48 60/49 60/49 62/50<br />

166 190 222 338<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />

1 x 6mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />

1 x 6mm <strong>BGC</strong> Duraliner TM<br />

SD027<br />

SD028<br />

SD038<br />

148 172 204 320<br />

Rw/Rw+Ctr<br />

46/38 46/38 48/39 49/39<br />

58/48 58/49 59/49 59/50<br />

60/50 61/51 62/52 62/53<br />

61/50 62/51 63/53 64/54<br />

63/52 64/52 65/53 66/55<br />

186 210 242 358


FRL<br />

- / 60 / 60<br />

FRL<br />

120 / 120 / 120<br />

STEEL FRAME INTERIOR WALL SYSTEM<br />

DOUBLE STUD<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

SD042<br />

148 172 204 320<br />

Rw/Rw+Ctr<br />

48/40 49/40 50/41 51/42<br />

60/51 60/52 61/53 61/55<br />

62/52 62/53 63/54 63/57<br />

63/53 64/54 65/55 65/58<br />

65/56 66/56 66/56 67/59<br />

192 216 248 364<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 9mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

PREVIOUSLY <strong>BGC</strong> DL001<br />

SD043<br />

148 172 204 320<br />

Rw/Rw+Ctr<br />

48/39 49/40 50/41 53/43<br />

60/51 61/52 61/53 61/55<br />

62/52 63/53 63/55 64/57<br />

63/52 63/53 64/55 65/58<br />

65/54 66/55 67/57 68/60<br />

198 222 254 370<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

04 / STEEL FRAME INFORMATION<br />

49


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 04 / STEEL FRAME INFORMATION<br />

50<br />

<strong>BGC</strong> CINEMA WALL SYSTEM<br />

SYSTEM SET OUT<br />

• Top hat sections (50mm x 35mm x 1.15m) fixed<br />

vertically at 900mm max centres to engineers design<br />

<strong>and</strong> supported at the head <strong>and</strong> the base with tracks<br />

• The span of the Top hats between girts shall be<br />

nominally 1.9m for single spans <strong>and</strong> 2.7m for<br />

continuous spans. To be confirmed as suitable<br />

by the engineer for internal wind pressures.<br />

• Steel columns <strong>and</strong> girts to be engineer specified<br />

• Girts to be fixed to vertical steel columns using<br />

proprietarty isolation mounts that include a<br />

through bolt<br />

FRL<br />

120 / 120 / 120<br />

FRL<br />

120 / 120 / 120<br />

MIN CAVITY mm<br />

CAVITY INFILL<br />

2 x Bradford Glasswool 110 (R2.5)<br />

2 x Autex AAB32-100<br />

2 x 30kg - 75mm Polyester<br />

WALL THICKNESS<br />

MIN CAVITY WIDTH mm<br />

CAVITY INFILL<br />

2 x Bradford Glasswool 110 (R2.5)<br />

2 x Autex AAB32-100<br />

2 x 30kg - 75mm Polyester<br />

WALL THICKNESS<br />

PLASTERBOARD FIXINGS<br />

• Layer 1 to Top hat – 30mm bugle head screws<br />

at 600mm centres<br />

• Layer 2 to Top hat – 45mm bugle head screws<br />

at 300mm centres <strong>and</strong> laminating screws at 300mm<br />

centres 200mm from top <strong>and</strong> bottom<br />

• Layer 3 to layer 2 – 38mm laminating screws at<br />

400mm x 400mm grid<br />

• Layer 4 to layer 3 – 38mm laminating screws at<br />

400mm x 400mm grid<br />

• 2 layers glasswool or polyester insulation.<br />

Refer to insulation in system specification<br />

• Perimeters to be caulked with fire rated caulking<br />

to a depth of 30mm x 10mm wide when used<br />

with a backing rod<br />

• Vertical control joints to be caulked to a depth of<br />

16mm backed with plaster<br />

STEEL TOP HATS AT 900mm MAX CENTRES<br />

Side 1 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

STEEL TOP HATS AT 900mm MAX CENTRES<br />

Side 1 4 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 4 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

375<br />

Rw<br />

75/68<br />

75/68<br />

74/67<br />

471<br />

375<br />

Rw<br />

79/72<br />

79/72<br />

78/71<br />

503<br />

SC001<br />

SC002


STEEL FRAME WITH ONE LAYER <strong>BGC</strong> FIREBOARD -<br />

VERTICAL SHEETING<br />

SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING<br />

FRAMING<br />

Lightweight Steel up to<br />

0.8mm<br />

Lightweight Steel 0.8mm<br />

to 1.6mm<br />

FIREBOARD THICKNESS<br />

13mm<br />

16mm<br />

13mm<br />

16mm<br />

STEEL FRAME WITH ONE LAYER <strong>BGC</strong> FIREBOARD -<br />

HORIZONTAL SHEETING<br />

INSTALLATION DETAILS<br />

STEEL STUD<br />

FIXING SPECIFICATIONS<br />

FASTENER SPACING<br />

300mm max. centres<br />

300mm max. centres<br />

200mm max. centres<br />

300mm max. centres<br />

SCREW TYPE<br />

No 6 Type S Needle Point<br />

No 6 Type S Needle Point<br />

No 6 Type D Drill Point<br />

No 6 Type D Drill Point<br />

SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING<br />

FRAMING<br />

Lightweight Steel up to<br />

0.8mm<br />

Lightweight Steel 0.8mm<br />

to 1.6mm<br />

FIREBOARD THICKNESS<br />

13mm<br />

16mm<br />

13mm<br />

16mm<br />

SCREW TYPE<br />

No 6 Type S Needle Point<br />

No 6 Type S Needle Point<br />

No 6 Type D Drill Point<br />

No 6 Type D Drill Point<br />

POSITION<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints<br />

Corners & Openings<br />

SCREW LENGTH<br />

1ST LAYER<br />

25mm<br />

30mm<br />

32mm<br />

32mm<br />

FIXING SPECIFICATIONS<br />

FASTENER SPACING<br />

300mm max. centres<br />

At each stud<br />

200mm max. centres<br />

300mm max. centres<br />

POSITION<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints<br />

Corners & Openings<br />

SCREW LENGTH<br />

1ST LAYER<br />

25mm<br />

30mm<br />

32mm<br />

32mm<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

04 / STEEL FRAME INFORMATION<br />

51


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 04 / STEEL FRAME INFORMATION<br />

52<br />

INSTALLATION DETAILS<br />

STEEL STUD<br />

STEEL FRAME WITH TWO LAYERS <strong>BGC</strong> FIREBOARD - VERTICAL SHEETING<br />

SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING<br />

FRAMING<br />

Lightweight Steel up to<br />

0.8mm<br />

Lightweight Steel 0.8mm<br />

to 1.6mm<br />

FIREBOARD THICKNESS<br />

13mm<br />

16mm<br />

13mm<br />

16mm<br />

STEEL FRAME WITH TWO LAYERS <strong>BGC</strong> FIREBOARD -<br />

FIRST LAYER VERTICAL, SECOND LAYER HORIZONTAL<br />

FIXING SPECIFICATIONS<br />

FIRST LAYER<br />

FASTENER SPACING<br />

600mm max. centres<br />

600mm max. centres<br />

600mm max. centres<br />

300mm max. centres<br />

300mm max. centres<br />

200mm max. centres<br />

300mm max. centres<br />

SCREW TYPE<br />

No 6 Type S Needle Point<br />

No 6 Type S Needle Point<br />

No 6 Type D Drill Point<br />

No 6 Type D Drill Point<br />

SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING<br />

FRAMING<br />

Lightweight Steel up to<br />

0.8mm<br />

Lightweight Steel 0.8mm<br />

to 1.6mm<br />

FIREBOARD THICKNESS<br />

13mm<br />

16mm<br />

13mm<br />

16mm<br />

FASTENER SPACING<br />

600mm max. centres<br />

600mm max. centres<br />

600mm max. centres<br />

SECOND LAYER<br />

LOCATION<br />

Centre of the Board<br />

Recessed Edges<br />

Corners & Openings<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints<br />

Corners & Openings<br />

FIXING SPECIFICATIONS<br />

FIRST LAYER<br />

300mm max. centres<br />

At Each Stud<br />

200mm max. centres<br />

300mm max. centres<br />

SCREW TYPE<br />

No 6 Type S Needle Point<br />

No 6 Type S Needle Point<br />

No 6 Type D Drill Point<br />

No 6 Type D Drill Point<br />

SECOND LAYER<br />

SCREW LENGTH<br />

1ST LAYER<br />

25mm<br />

30mm<br />

32mm<br />

32mm<br />

2ND LAYER<br />

45mm<br />

45mm<br />

45mm<br />

45mm<br />

LOCATION<br />

Centre of the Board<br />

Recessed Edges<br />

Corners & Openings<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints<br />

Corners & Openings<br />

SCREW LENGTH<br />

1ST LAYER<br />

25mm<br />

30mm<br />

32mm<br />

32mm<br />

2ND LAYER<br />

45mm<br />

45mm<br />

45mm<br />

45mm


STEEL FRAME WITH THREE LAYERS <strong>BGC</strong> FIREBOARD -<br />

VERTICAL SHEETING<br />

INSTALLATION DETAILS<br />

STEEL STUD<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

FIXING SPECIFICATIONS THREE LAYER<br />

VERTICAL(Shown)<br />

FIRST LAYER<br />

FASTENER SPACING<br />

600mm max. centres<br />

600mm max. centres<br />

600mm max. centres<br />

300mm max. centres<br />

300mm max. centres<br />

200mm max. centres<br />

300mm max. centres<br />

Laminating Screws at<br />

400mm max. grid<br />

SECOND LAYER<br />

THIRD LAYER<br />

LOCATION<br />

Centre of the Board<br />

Recessed Edges<br />

Corners & Openings<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints<br />

Corners & Openings<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints<br />

Corners & Openings<br />

SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING<br />

FRAMING<br />

Lightweight Steel up to<br />

0.8mm<br />

Lightweight Steel 0.8mm<br />

to 1.6mm<br />

FIREBOARD THICKNESS<br />

13mm<br />

16mm<br />

13mm<br />

16mm<br />

FIXING SPECIFICATIONS<br />

THREE LAYER HORIZONTAL<br />

FIRST LAYER<br />

FASTENER SPACING<br />

600mm max. centres<br />

600mm max. centres<br />

600mm max. centres<br />

300mm max. centres<br />

600mm max. centres<br />

200mm max. centres<br />

300mm max. centres<br />

Laminating Screws at<br />

400mm max. grid<br />

SCREW TYPE<br />

No 6 Type S Needle Point<br />

No 6 Type S Needle Point<br />

No 6 Type D Drill Point<br />

No 6 Type D Drill Point<br />

SECOND LAYER<br />

THIRD LAYER<br />

LOCATION<br />

Centre of the Board<br />

Recessed Edges<br />

Corners & Openings<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints<br />

Corners & Openings<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints<br />

Corners & Openings<br />

SCREW LENGTH<br />

1ST LAYER<br />

25mm<br />

30mm<br />

32mm<br />

32mm<br />

2ND LAYER<br />

45mm<br />

45mm<br />

45mm<br />

45mm<br />

04 / STEEL FRAME INFORMATION 53


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 04 / STEEL FRAME INFORMATION<br />

54<br />

INSTALLATION DETAILS<br />

STEEL STUD<br />

LOAD BEARING WALL 60/60/60<br />

Note: Refer to page 10 for screw lengths.<br />

SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING<br />

FRAMING<br />

Lightweight Steel up to<br />

0.8mm<br />

Lightweight Steel 0.8mm<br />

to 1.6mm<br />

FIREBOARD THICKNESS<br />

13mm<br />

16mm<br />

13mm<br />

16mm<br />

SCREW TYPE<br />

No 6 Type S Needle Point<br />

No 6 Type S Needle Point<br />

No 6 Type D Drill Point<br />

No 6 Type D Drill Point<br />

FIXING SPECIFICATIONS<br />

FASTENER SPACING<br />

300mm max. centres<br />

At each stud<br />

100mm max. centres<br />

300mm max. centres<br />

SCREW LENGTH<br />

1ST LAYER<br />

25mm<br />

30mm<br />

32mm<br />

32mm<br />

POSITION<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints<br />

Corners & Openings


FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

TIMBER FRAME INTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 1 x 10mm <strong>BGC</strong> Plasterboard<br />

Side 2 1 x 10mm <strong>BGC</strong> Plasterboard<br />

70 90 120 140<br />

Rw/Rw+Ctr<br />

31/25 32/26 33/27 33/27<br />

37/28 37/28 38/30 39/32<br />

37/28 38/29 39/30 39/32<br />

90 110 140 160<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> Plasterboard<br />

Side 2 1 x 13mm <strong>BGC</strong> Plasterboard<br />

70 90 120 140<br />

Rw/Rw+Ctr<br />

34/28 35/30 36/30 37/31<br />

39/32 40/32 41/35 41/35<br />

40/32 40/32 41/35 41/35<br />

96 116 146 166<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 2 x 10mm <strong>BGC</strong> Plasterboard<br />

Side 2 2 x 10mm <strong>BGC</strong> Plasterboard<br />

T001<br />

T002<br />

T004<br />

70 90 120 140<br />

Rw/Rw+Ctr<br />

39/31 39/33 40/33 41/34<br />

44/36 45/37 45/40 45/40<br />

44/36 45/38 45/40 46/40<br />

90 110 140 160<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

05 / TIMBER FRAME INFORMATION<br />

55


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 05 / TIMBER FRAME INFORMATION<br />

56<br />

TIMBER FRAME INTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 2 x 13mm <strong>BGC</strong> Plasterboard<br />

Side 2 2 x 13mm <strong>BGC</strong> Plasterboard<br />

70 90 120 140<br />

Rw/Rw+Ctr<br />

41/35 43/37 43/37 44/37<br />

46/41 47/42 47/42 47/43<br />

46/41 47/42 47/43 47/43<br />

122 142 172 192<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 1 x 10mm <strong>BGC</strong> Soundboard TM<br />

Side 2 1 x 10mm <strong>BGC</strong> Soundboard TM<br />

T005<br />

T006<br />

70 90 120 140<br />

Rw/Rw+Ctr<br />

34/29 35/29 35/29 36/30<br />

39/31 39/32 40/35 40/34<br />

39/31 39/32 40/35 40/35<br />

90 110 140 160<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> Soundboard TM<br />

Side 2 1 x 13mm <strong>BGC</strong> Soundboard TM<br />

T007<br />

STUD DEPTH mm 70 90 120 140<br />

Rw/Rw+Ctr<br />

36/31 37/31 38/33 38/33<br />

40/34 40/36 40/37 40/37<br />

40/34 41/36 41/37 41/38<br />

96 116 146 166


FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / 60 / 60<br />

60 / 60 / 60<br />

TIMBER FRAME INTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

STUD DEPTH mm 70 90 120 140<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

35/29 35/29 36/30 37/30<br />

9kg - 50mm Polyester<br />

39/31 40/31 41/35 41/34<br />

30kg - 75mm Polyester<br />

39/31 40/32 41/35 41/35<br />

WALL THICKNESS mm<br />

90 110 140 160<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 2 x 10mm <strong>BGC</strong> Soundboard TM<br />

Side 2 2 x 10mm <strong>BGC</strong> Soundboard TM<br />

STUD DEPTH mm 70 90 120 140<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 1 x 10mm <strong>BGC</strong> Soundboard TM<br />

Side 2 1 x 10mm <strong>BGC</strong> WR Plasterboard<br />

Rw/Rw+Ctr<br />

43/37 44/37 44/38 45/39<br />

47/41 48/43 48/44 48/44<br />

47/42 48/43 48/44 48/44<br />

110 130 160 180<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

PREVIOUSLY <strong>BGC</strong> 005<br />

T008<br />

T010<br />

T011<br />

STUD DEPTH mm 70 90 120 140<br />

Rw/Rw+Ctr<br />

35/30 36/31 37/32 38/33<br />

40/32 41/35 41/36 41/37<br />

40/33 41/35 41/36 42/37<br />

96 116 146 166<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

05 / TIMBER FRAME INFORMATION<br />

57


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

TIMBER FRAME INTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> Plasterboard<br />

Side 2 1 x 10mm <strong>BGC</strong> Plasterboard<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

T015<br />

05 / TIMBER FRAME INFORMATION 58<br />

FRL<br />

- / - / -<br />

FRL<br />

- / 60 / 60<br />

60 / 60 / 60<br />

FRL<br />

- / 120 / 120<br />

STUD DEPTH mm 70 90 120 140<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

37/31 37/31 39/33 39/32<br />

9kg - 50mm Polyester<br />

41/33 42/36 43/37 43/38<br />

30kg - 75mm Polyester<br />

42/33 42/37 43/38 43/39<br />

WALL THICKNESS mm<br />

106 126 156 176<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

PREVIOUSLY <strong>BGC</strong> 007<br />

T019<br />

STUD DEPTH mm<br />

70 90 120 140<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

36/31<br />

40/34<br />

40/34<br />

102<br />

37/31<br />

40/36<br />

41/36<br />

122<br />

38/33<br />

40/37<br />

41/37<br />

152<br />

38/33<br />

40/37<br />

41/38<br />

172<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

T021<br />

STUD DEPTH mm<br />

70 90 120 140<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

44/39<br />

48/43<br />

48/43<br />

122<br />

44/39<br />

48/44<br />

48/44<br />

142<br />

45/40<br />

48/45<br />

48/45<br />

172<br />

46/40<br />

48/45<br />

48/45<br />

192


TIMBER FRAME INTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

T022<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

FRL<br />

60 / 60 / 60<br />

FRL<br />

- / 120 / 120<br />

FRL<br />

- / 180 / 180<br />

STUD DEPTH mm<br />

70 90 120 140<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

40/35<br />

44/39<br />

44/39<br />

122<br />

41/37<br />

44/40<br />

44/41<br />

142<br />

42/37<br />

44/41<br />

44/41<br />

172<br />

42/37<br />

44/41<br />

44/41<br />

192<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

T023<br />

STUD DEPTH mm<br />

70 90 120 140<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

45/40<br />

48/45<br />

48/45<br />

134<br />

46/40<br />

48/45<br />

48/45<br />

154<br />

46/41<br />

48/45<br />

48/45<br />

184<br />

47/42<br />

48/45<br />

48/45<br />

204<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

T026<br />

STUD DEPTH mm 70 90 120 140<br />

CAVITY INFILL<br />

Rw/Rw+Ctr<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

134 154 184 204<br />

05 / TIMBER FRAME INFORMATION 59


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

TIMBER FRAME INTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

T027<br />

05 / TIMBER FRAME INFORMATION 60<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

60 / 60 / 60<br />

STUD DEPTH mm 70 90 120 140<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

PREVIOUSLY <strong>BGC</strong> DL003<br />

Rw/Rw+Ctr<br />

33/26 33/26 34/27 34/27<br />

40/30 41/31 42/34 42/34<br />

40/30 41/31 43/34 43/34<br />

82 102 132 152<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 1 x 10mm <strong>BGC</strong> Soundboard TM (against stud)<br />

1 x 6mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 10mm <strong>BGC</strong> Soundboard TM (against stud)<br />

1 x 6mm <strong>BGC</strong> Duraliner TM<br />

T037<br />

STUD DEPTH mm 70 90 120 140<br />

Rw/Rw+Ctr<br />

41/34 42/36 43/36 43/36<br />

46/39 47/41 47/42 47/42<br />

46/39 47/41 47/42 47/43<br />

102 122 152 172<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

T039<br />

STUD DEPTH mm 70 90 120 140<br />

Rw/Rw+Ctr<br />

42/36 43/37 44/38 44/38<br />

47/41 47/43 48/43 48/44<br />

47/41 48/43 48/44 48/44<br />

108 128 158 178


FRL<br />

90 / 90 / 90<br />

FRL<br />

- / 180 / 180<br />

FRL<br />

- / 60 / 60<br />

TIMBER FRAME INTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

PREVIOUSLY <strong>BGC</strong> DL004<br />

T042<br />

STUD DEPTH mm 70 90 120 140<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

44/39 45/39 46/40 46/40<br />

48/43 48/44 48/45 48/45<br />

48/43 48/44 48/45 48/45<br />

114 134 164 184<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1 2 x 16mm Wet Area <strong>Fire</strong>board<br />

Side 2 2 x 16mm Wet Area <strong>Fire</strong>board<br />

T044<br />

70 90 120 140<br />

Rw/Rw+Ctr<br />

45/40 46/40 46/41 47/42<br />

48/45 48/45 48/45 48/45<br />

48/45 48/45 48/45 48/45<br />

114 134 164 184<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1<br />

Side 2 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

STUD DEPTH mm 70 90 120 140<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

T046<br />

Rw/Rw+Ctr<br />

35/32 - - -<br />

- - - -<br />

- - - -<br />

102 122 152 172<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

05 / TIMBER FRAME INFORMATION<br />

61


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 05 / TIMBER FRAME INFORMATION<br />

62<br />

TIMBER FRAME INTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

FRL<br />

- / 90 / 90<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINGS AT 1350mm MAX CENTRES<br />

Side 1<br />

Side 2 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

STUD DEPTH mm 70 90 120 140<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

T048<br />

Rw/Rw+Ctr<br />

38/36 - - -<br />

- - - -<br />

- - - -<br />

118 138 168 188


FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / 60 / 60<br />

TIMBER FRAME INTERIOR WALL SYSTEM<br />

STAGGERED STUD<br />

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />

MIN 20mm CLEARANCE BETWEEN STUD AND<br />

OPPOSING WALL LINING<br />

Side 1 1 x 10mm <strong>BGC</strong> Soundboard TM<br />

Side 2 1 x 10mm <strong>BGC</strong> Soundboard TM<br />

PLATE WIDTH mm 90 120 140<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

33/27 34/28 35/29<br />

43/34 45/38 45/37<br />

44/34 46/38 46/38<br />

110 140 160<br />

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />

MIN 20mm CLEARANCE BETWEEN STUD AND<br />

OPPOSING WALL LINING<br />

Side 1 2 x 10mm <strong>BGC</strong> Soundboard TM<br />

Side 2 2 x 10mm <strong>BGC</strong> Soundboard TM<br />

PLATE WIDTH mm 90 120 140<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

42/35 43/36 44/36<br />

52/45 52/46 53/47<br />

52/45 53/47 53/47<br />

130 160 180<br />

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />

MIN 20mm CLEARANCE BETWEEN STUD AND<br />

OPPOSING WALL LINING<br />

Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

PLATE WIDTH mm 90 120 140<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

TS006<br />

TS010<br />

TS011<br />

35/29 37/31 37/32<br />

45/37 46/38 46/40<br />

45/37 46/39 47/40<br />

116 146 166<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

05 / TIMBER FRAME INFORMATION<br />

63


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 05 / TIMBER FRAME INFORMATION<br />

64<br />

TIMBER FRAME INTERIOR WALL SYSTEM<br />

STAGGERED STUD<br />

FRL<br />

- / 90 / 90<br />

FRL<br />

- / 120 / 120<br />

FRL<br />

- / 120 / 120<br />

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />

MIN 20mm CLEARANCE BETWEEN STUD AND<br />

OPPOSING WALL LINING<br />

Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

PLATE WIDTH mm 90 120 140<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

36/30 38/32 38/32<br />

46/39 46/40 46/41<br />

46/39 46/40 47/42<br />

122 152 172<br />

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />

MIN 20mm CLEARANCE BETWEEN STUD AND<br />

OPPOSING WALL LINING<br />

Side 1 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

PLATE WIDTH mm 90 120 140<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

42/36 43/37 44/37<br />

52/46 53/48 53/48<br />

53/47 53/48 53/49<br />

142 172 192<br />

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />

MIN 20mm CLEARANCE BETWEEN STUD AND<br />

OPPOSING WALL LINING<br />

Side 1 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

PLATE WIDTH mm 90 120 140<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

TS019<br />

TS021<br />

TS023<br />

43/37 45/38 45/38<br />

53/48 53/49 53/49<br />

53/49 53/50 53/50<br />

154 184 204


FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

TIMBER FRAME INTERIOR WALL SYSTEM<br />

STAGGERED STUD<br />

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />

MIN 20mm CLEARANCE BETWEEN STUD AND<br />

OPPOSING WALL LINING<br />

Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

PLATE WIDTH mm 90 120 140<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />

MIN 20mm CLEARANCE BETWEEN STUD AND<br />

OPPOSING WALL LINING<br />

Side 1 1 x 9mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM<br />

PLATE WIDTH mm 90 120 140<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />

MIN 20mm CLEARANCE BETWEEN STUD AND<br />

OPPOSING WALL LINING<br />

Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 10mm <strong>BGC</strong> Plasterboard<br />

PLATE WIDTH mm 90 120 140<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

Rw/Rw+Ctr<br />

37/30 39/32 39/31<br />

47/38 48/39 48/40<br />

47/38 48/40 48/40<br />

108 138 158<br />

Rw/Rw+Ctr<br />

TS027<br />

33/26 33/25 33/26<br />

43/31 45/35 45/35<br />

43/31 45/35 46/35<br />

102 132 152<br />

TS028<br />

TS030<br />

32/25 33/26 33/26<br />

42/31 44/34 45/36<br />

43/31 45/34 46/35<br />

106 136 156<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

05 / TIMBER FRAME INFORMATION<br />

65


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 05 / TIMBER FRAME INFORMATION<br />

66<br />

TIMBER FRAME INTERIOR WALL SYSTEM<br />

STAGGERED STUD<br />

FRL<br />

- / - / -<br />

FRL<br />

60 / 60 / 60<br />

FRL<br />

60 / 60 / 60<br />

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />

MIN 20mm CLEARANCE BETWEEN STUD AND<br />

OPPOSING WALL LINING<br />

Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 10mm <strong>BGC</strong> Soundboard TM<br />

PLATE WIDTH mm 90 120 140<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />

MIN 20mm CLEARANCE BETWEEN STUD AND<br />

OPPOSING WALL LINING<br />

Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

PLATE WIDTH mm 90 120 140<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

42/34 43/35 43/36<br />

52/46 53/47 53/47<br />

53/46 53/47 53/47<br />

128 158 178<br />

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />

MIN 20mm CLEARANCE BETWEEN STUD AND<br />

OPPOSING WALL LINING<br />

Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />

1 x 6mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />

1 x 6mm <strong>BGC</strong> Duraliner TM<br />

PLATE WIDTH mm 90 120 140<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

Rw/Rw+Ctr<br />

Rw/Rw+Ctr<br />

TS031<br />

33/26 33/26 34/27<br />

43/32 45/36 45/35<br />

43/32 46/36 46/36<br />

106 136 156<br />

TS039<br />

TS040<br />

42/34 43/36 44/36<br />

52/46 53/48 53/48<br />

53/47 53/48 53/49<br />

134 164 184


FRL<br />

90 / 90 / 90<br />

TIMBER FRAME INTERIOR WALL SYSTEM<br />

STAGGERED STUD<br />

STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />

MIN 20mm CLEARANCE BETWEEN STUD AND<br />

OPPOSING WALL LINING<br />

Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

PREVIOUSLY <strong>BGC</strong> DL004<br />

PLATE WIDTH mm 90 120 140<br />

Rw/Rw+Ctr<br />

TS042<br />

42/34 43/36 44/36<br />

52/46 53/48 53/48<br />

53/47 53/48 53/49<br />

134 164 184<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

05 / TIMBER FRAME INFORMATION<br />

67


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 05 / TIMBER FRAME INFORMATION<br />

68<br />

TIMBER FRAME INTERIOR WALL SYSTEM<br />

DOUBLE STUD<br />

FRL<br />

- / 60 / 60<br />

FRL<br />

- / 60 / 60<br />

FRL<br />

- / 60 / 60<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

160 200 260 300<br />

Rw/Rw+Ctr<br />

40/34 42/35 43/35 44/36<br />

52/44 53/45 53/47 53/47<br />

54/45 55/47 55/48 55/49<br />

55/45 56/48 56/48 56/49<br />

57/46 58/48 59/49 59/49<br />

186 226 286 326<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 13mm <strong>BGC</strong> Plasterboard (against stud)<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 13mm <strong>BGC</strong> Plasterboard (against stud)<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

TD011<br />

TD013<br />

160 200 260 300<br />

Rw/Rw+Ctr<br />

46/37 47/38 48/38 49/39<br />

57/48 57/49 58/49 58/51<br />

60/50 61/52 61/53 61/53<br />

61/50 61/52 62/54 62/55<br />

63/52 64/54 65/55 65/55<br />

212 252 312 352<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 10mm <strong>BGC</strong> Plasterboard (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 10mm <strong>BGC</strong> Plasterboard (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

TD017<br />

CAVITY WIDTH mm 160 200 260 300<br />

Rw/Rw+Ctr<br />

Nil<br />

46/38 47/39 48/39 49/40<br />

9kg – 50mm Polyester – 1 side<br />

57/49 58/49 58/49 58/51<br />

9kg – 50mm Polyester – 2 sides<br />

60/51 61/52 61/53 61/53<br />

30kg – 75mm Polyester – 1 side<br />

61/51 62/53 63/54 63/55<br />

30kg – 75mm Polyester – 2 sides<br />

63/52 64/54 65/55 65/55<br />

WALL THICKNESS mm<br />

212 252 312 352


FRL<br />

- / 60 / 60<br />

60 / 60 / 60<br />

FRL<br />

- / 120 / 120<br />

FRL<br />

- / 120 / 120<br />

TIMBER FRAME INTERIOR WALL SYSTEM<br />

DOUBLE STUD<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

160 200 260 300<br />

Rw/Rw+Ctr<br />

42/35 43/36 45/37 45/37<br />

54/46 55/48 55/49 55/49<br />

56/48 57/49 57/49 57/50<br />

57/48 58/49 58/49 58/51<br />

59/48 60/49 61/50 61/51<br />

192 232 292 332<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

160 200 260 300<br />

Rw/Rw+Ctr<br />

48/40 50/41 51/43 52/43<br />

60/51 60/53 61/55 61/55<br />

62/53 63/55 63/56 63/57<br />

63/53 64/55 64/56 64/57<br />

65/54 65/55 66/57 66/58<br />

212 252 312 352<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

TD019<br />

TD021<br />

TD023<br />

160 200 260 300<br />

Rw/Rw+Ctr<br />

48/39 49/41 51/42 52/43<br />

60/52 61/54 61/55 61/56<br />

62/54 63/55 64/57 64/57<br />

63/54 64/56 65/57 65/58<br />

65/54 66/57 67/58 67/59<br />

224 264 324 364<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

05 / TIMBER FRAME INFORMATION<br />

69


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 05 / TIMBER FRAME INFORMATION<br />

70<br />

TIMBER FRAME INTERIOR WALL SYSTEM<br />

DOUBLE STUD<br />

FRL<br />

- / 120 / 120<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />

Side 1 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

160 200 260 300<br />

Rw/Rw+Ctr<br />

54/45 56/46 58/48 59/49<br />

67/59 68/61 69/62 69/63<br />

69/61 70/62 71/64 71/65<br />

70/61 71/63 72/64 72/65<br />

72/61 73/63 73/65 73/65<br />

256 296 356 396<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

160 200 260 300<br />

Rw/Rw+Ctr<br />

38/30 38/31 39/32 40/32<br />

51/41 51/43 52/44 52/45<br />

52/42 53/45 54/46 54/46<br />

53/42 54/45 55/47 55/47<br />

55/43 56/46 57/48 57/49<br />

172 212 272 312<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 9mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM<br />

TD026<br />

TD027<br />

TD028<br />

160 200 260 300<br />

Rw/Rw+Ctr<br />

42/34 43/35 44/36 45/36<br />

55/45 55/46 56/48 56/48<br />

56/46 57/48 58/49 58/50<br />

58/47 58/49 58/49 58/51<br />

59/47 60/49 61/49 61/52<br />

178 218 278 318


FRL<br />

60 / 60 / 60<br />

FRL<br />

60 / 60 / 60<br />

FRL<br />

90 / 90 / 90<br />

TIMBER FRAME INTERIOR WALL SYSTEM<br />

DOUBLE STUD<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

CAVITY WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg – 50mm Polyester – 1 side<br />

9kg – 50mm Polyester – 2 sides<br />

30kg – 75mm Polyester – 1 side<br />

30kg – 75mm Polyester – 2 sides<br />

WALL THICKNESS mm<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

PREVIOUSLY <strong>BGC</strong> DL003<br />

160 200 260 300<br />

Rw/Rw+Ctr<br />

46/38 47/39 48/39 49/40<br />

58/49 59/49 59/49 59/51<br />

60/50 60/52 61/53 61/53<br />

61/51 62/53 63/54 63/54<br />

63/52 64/53 65/55 65/55<br />

198 238 298 338<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />

1 x 6mm <strong>BGC</strong> Duraliner TM<br />

Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />

1 x 6mm <strong>BGC</strong> Duraliner TM<br />

160 200 260 300<br />

Rw/Rw+Ctr<br />

48/39 49/40 51/41 52/42<br />

60/51 61/53 61/54 61/55<br />

62/53 63/54 63/56 63/57<br />

63/53 64/54 64/56 64/57<br />

65/53 65/55 66/57 66/58<br />

204 244 304 344<br />

MIN 20mm GAP BETWEEN STUD WALLS<br />

2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

PREVIOUSLY <strong>BGC</strong> DL004<br />

TD039<br />

TD040<br />

TD042<br />

160 200 260 300<br />

Rw/Rw+Ctr<br />

48/39 49/40 51/41 52/42<br />

60/51 61/53 61/54 61/55<br />

62/53 63/54 63/56 63/57<br />

63/53 64/54 64/56 64/57<br />

65/53 65/55 66/57 66/58<br />

204 244 304 344<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

05 / TIMBER FRAME INFORMATION<br />

71


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 05 / TIMBER FRAME INFORMATION<br />

72<br />

INSTALLATION DETAILS<br />

TIMBER STUD<br />

TIMBER FRAME WITH ONE LAYER <strong>BGC</strong> FIREBOARD -<br />

HORIZONTAL SHEETING<br />

TIMBER FRAME WITH ONE LAYER <strong>BGC</strong> FIREBOARD -<br />

VERTICAL SHEETING<br />

SCREW FIXINGS FOR SOFT WOOD TIMBER FRAMING<br />

FRAMING<br />

Soft Wood Timber<br />

FIREBOARD THICKNESS<br />

13mm<br />

16mm<br />

FIXING SPECIFICATIONS<br />

FASTENER SPACING<br />

2 Nails 50mm apart at<br />

300mm max. centres<br />

1 screw at 200mm<br />

max. centres<br />

At Each Stud<br />

Nails at 150mm max.<br />

centres Screws at<br />

200mm max. centres<br />

Nails at 150mm<br />

max. centres Screws<br />

at 200mm max.<br />

centres<br />

FASTENER SPACING<br />

2 Nails 50mm apart at<br />

300mm max. centres<br />

1 screw at 200mm<br />

max. centres<br />

At Each Stud<br />

Nails at 150mm max.<br />

centres Screws at<br />

200mm max. centres<br />

Nails at 150mm<br />

max. centres Screws<br />

at 200mm max.<br />

centres<br />

SCREW TYPE<br />

No 6 Type W<br />

No 6 Type W<br />

LOCATION<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints<br />

Corners & Openings<br />

FIXING SPECIFICATIONS<br />

LOCATION<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints<br />

Corners & Openings<br />

SCREW LENGTH<br />

1ST LAYER<br />

32mm<br />

45mm


TIMBER FRAME WITH TWO LAYERS <strong>BGC</strong> FIREBOARD -<br />

HORIZONTAL SHEETING<br />

SCREW FIXINGS FOR SOFT WOOD TIMBER FRAMING<br />

FRAMING<br />

Soft Wood Timber<br />

FIREBOARD THICKNESS<br />

13mm<br />

16mm<br />

INSTALLATION DETAILS<br />

TIMBER STUD<br />

FASTENER SPACING<br />

Nails or Screws<br />

600mm max. centres<br />

Nails or Screws<br />

600mm max. centres<br />

Nails or Screws<br />

600mm max. centres<br />

in stagered pattern<br />

2 Nails 50mm apart at<br />

300mm max. centres<br />

1 screw at 200mm<br />

max. centres<br />

Nails or screws at<br />

300mm max. centres<br />

Nails at 150mm max.<br />

centres Screws at<br />

200mm max. centres<br />

Nails at 150mm<br />

max. centres Screws<br />

at 300mm max.<br />

centres<br />

SCREW TYPE<br />

No 6 Type W<br />

No 6 Type W<br />

FIXING SPECIFICATIONS<br />

FIRST LAYER<br />

SECOND LAYER<br />

LOCATION<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints<br />

on noggins<br />

Corners & Openings<br />

SCREW LENGTH<br />

1ST LAYER<br />

32mm<br />

45mm<br />

2ND LAYER<br />

50mm<br />

65mm<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

05 / TIMBER FRAME INFORMATION<br />

73


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 05 / TIMBER FRAME INFORMATION<br />

74<br />

INSTALLATION DETAILS<br />

TIMBER STUD<br />

TIMBER FRAME WITH THREE LAYERS <strong>BGC</strong> FIREBOARD -<br />

VERTICAL SHEETING<br />

FIXING SPECIFICATIONS<br />

THREE LAYER HORIZONTAL<br />

FIRST LAYER<br />

FASTENER SPACING<br />

600mm max. centres<br />

Fasteners at each stud<br />

600mm max. centres<br />

2 nails 50mm apart at<br />

300mm max. centre<br />

1 scew at 200mm max.<br />

centres<br />

Fasteners at each stud<br />

Nails 300mm max<br />

Screws 150mm max<br />

centres<br />

Laminating Screws at<br />

400mm max. grid<br />

Laminating Screws<br />

400mm max. centres<br />

SECOND LAYER<br />

THIRD LAYER<br />

LOCATION<br />

Centre of the Board<br />

Recessed Edges<br />

Corners & Openings<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints on studs<br />

Centre of the Board<br />

Recessed Edges<br />

Corners & Openings<br />

Butt Joints<br />

SCREW FIXINGS FOR SOFT WOOD TIMBER FRAMING<br />

FRAMING<br />

Soft Wood Timber<br />

FIREBOARD THICKNESS<br />

13mm<br />

16mm<br />

SCREW TYPE<br />

No 6 Type W<br />

No 6 Type W<br />

FIXING SPECIFICATIONS THREE LAYER<br />

VERTICAL-VERTICAL SHEETING (Shown)<br />

FIRST LAYER<br />

FASTENER SPACING<br />

600mm max. centres<br />

600mm max. centres<br />

600mm max. centres<br />

SECOND LAYER<br />

LOCATION<br />

Centre of the Board<br />

Recessed Edges<br />

Corners & Openings<br />

2 nails 50mm apart at<br />

300mm max. centre<br />

Centre of the Board<br />

1 scew at 300mm max.<br />

centres<br />

300mm max. centres Recessed Edges<br />

Laminating Screws<br />

200mm max. centres<br />

Butt Joints<br />

Nail screws 150mm max Corners & Openings<br />

300mm max. centres<br />

THIRD LAYER<br />

Laminating Screws at<br />

400mm max. grid<br />

Laminating Screws<br />

200mm max. centres<br />

1ST LAYER<br />

32mm<br />

45mm<br />

Centre of the Board<br />

Recessed Edges<br />

Corners & Openings<br />

SCREW LENGTH<br />

2ND LAYER<br />

50mm<br />

65mm<br />

Butt Joints<br />

3RD LAYER<br />

50mm<br />

65mm


FRL<br />

60 / 60 / 60<br />

FRL<br />

90 / 90 / 90<br />

FRL<br />

60 / 60 / 60<br />

TIMBER FRAME EXTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINS AT 1350mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 7.5mm Duratex TM<br />

Side 2<br />

STUD WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

1 x 10mm <strong>BGC</strong> Plasterboard<br />

<strong>Fire</strong> rated from outside only<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINS AT 1350mm MAX CENTRES<br />

Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 7.5mm Duratex TM<br />

Side 2<br />

STUD WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

1 x 10mm <strong>BGC</strong> Plasterboard<br />

<strong>Fire</strong> rated from outside only<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINS AT 1350mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 9mm Duragrid TM<br />

Side 2<br />

STUD WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

1 x 10mm <strong>BGC</strong> Plasterboard<br />

<strong>Fire</strong> rated from outside only<br />

Timber batten can be substituted for steel batten<br />

90<br />

41/35<br />

45/38<br />

45/38<br />

123.5<br />

90<br />

45/39<br />

48/42<br />

48/42<br />

123.5<br />

90<br />

38/27<br />

45/34<br />

45/34<br />

125<br />

120<br />

Rw/Rw+Ctr<br />

42/35<br />

46/40<br />

46/41<br />

123.5<br />

120<br />

Rw/Rw+Ctr<br />

45/39<br />

48/44<br />

48/45<br />

123.5<br />

120<br />

Rw/Rw+Ctr<br />

41/31<br />

47/37<br />

47/37<br />

155<br />

TE001<br />

140<br />

42/36<br />

46/41<br />

46/41<br />

123.5<br />

TE002<br />

140<br />

46/39<br />

48/45<br />

49/45<br />

123.5<br />

TE003<br />

140<br />

43/34<br />

48/39<br />

48/39<br />

175<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

06 / EXTERIOR WALL INFORMATION<br />

75


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 06 / EXTERIOR WALL INFORMATION<br />

76<br />

TIMBER FRAME EXTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

FRL<br />

90 / 90 / 90<br />

FRL<br />

60 / 60 / 60<br />

FRL<br />

90 / 90 / 90<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINS AT 1350mm MAX CENTRES<br />

Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 9mm Duragrid TM<br />

Side 2<br />

STUD WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

1 x 10mm <strong>BGC</strong> Plasterboard<br />

<strong>Fire</strong> rated from outside only<br />

Timber batten can be substituted for stee<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINS AT 1350mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 9mm Duracom TM<br />

Side 2<br />

STUD WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

1 x 10mm <strong>BGC</strong> Plasterboard<br />

<strong>Fire</strong> rated from outside only<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINS AT 1350mm MAX CENTRES<br />

Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 9mm Duracom TM<br />

Side 2<br />

STUD WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

1 x 10mm <strong>BGC</strong> Plasterboard<br />

<strong>Fire</strong> rated from outside only<br />

90<br />

42/30<br />

48/37<br />

48/37<br />

141<br />

90<br />

40/28<br />

46/34<br />

46/34<br />

125<br />

90<br />

40/28<br />

49/34<br />

49/34<br />

141<br />

120<br />

Rw/Rw+Ctr<br />

45/35<br />

50/40<br />

50/40<br />

171<br />

120<br />

Rw/Rw+Ctr<br />

43/32<br />

48/37<br />

48/37<br />

155<br />

120<br />

Rw/Rw+Ctr<br />

44/32<br />

50/37<br />

50/37<br />

171<br />

TE004<br />

140<br />

47/37<br />

51/41<br />

51/41<br />

191<br />

TE005<br />

140<br />

44/34<br />

48/38<br />

48/38<br />

175<br />

TE006<br />

140<br />

45/34<br />

51/39<br />

51/39<br />

191


FRL<br />

60 / 60 / 60<br />

FRL<br />

90 / 90 / 90<br />

FRL<br />

60 / 60 / 60<br />

TIMBER FRAME EXTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINS AT 1350mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 14mm Nuline TM Plus<br />

Side 2<br />

STUD WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

1 x 10mm <strong>BGC</strong> Plasterboard<br />

<strong>Fire</strong> rated from outside only<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINS AT 1350mm MAX CENTRES<br />

Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 14mm Nuline TM Plus<br />

Side 2<br />

STUD WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

1 x 10mm <strong>BGC</strong> Plasterboard<br />

<strong>Fire</strong> rated from outside only<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINS AT 1350mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 9mm Durascape TM<br />

Side 2<br />

STUD WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

1 x 10mm <strong>BGC</strong> Plasterboard<br />

<strong>Fire</strong> rated from outside only<br />

90<br />

41/30<br />

46/34<br />

46/34<br />

130<br />

90<br />

42/29<br />

48/34<br />

48/34<br />

146<br />

90<br />

42/36<br />

46/39<br />

46/40<br />

125<br />

120<br />

Rw/Rw+Ctr<br />

41/31<br />

47/37<br />

47/37<br />

160<br />

120<br />

Rw/Rw+Ctr<br />

44/31<br />

50/37<br />

50/37<br />

176<br />

120<br />

Rw/Rw+Ctr<br />

43/36<br />

46/41<br />

46/41<br />

155<br />

TE007<br />

140<br />

44/33<br />

48/38<br />

48/38<br />

180<br />

TE008<br />

140<br />

46/33<br />

50/38<br />

50/38<br />

196<br />

TE009<br />

140<br />

43/37<br />

46/41<br />

46/42<br />

175<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

06 / EXTERIOR WALL INFORMATION<br />

77


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 06 / EXTERIOR WALL INFORMATION<br />

78<br />

TIMBER FRAME EXTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

FRL<br />

90 / 90 / 90<br />

FRL<br />

60 / 60 / 60<br />

FRL<br />

90 / 90 / 90<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINS AT 1350mm MAX CENTRES<br />

Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 9mm Durascape TM<br />

Side 2<br />

STUD WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

1 x 10mm <strong>BGC</strong> Plasterboard<br />

<strong>Fire</strong> rated from outside only<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINS AT 1350mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 9mm Duragroove TM<br />

Side 2<br />

STUD WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

1 x 10mm <strong>BGC</strong> Plasterboard<br />

<strong>Fire</strong> rated from outside only<br />

TIMBER STUDS AT 600mm MAX CENTRES<br />

WITH NOGGINS AT 1350mm MAX CENTRES<br />

Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 9mm Duragroove TM<br />

Side 2<br />

STUD WIDTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

1 x 10mm <strong>BGC</strong> Plasterboard<br />

<strong>Fire</strong> rated from outside only<br />

90<br />

45/39<br />

48/43<br />

48/43<br />

141<br />

90<br />

42/36<br />

46/39<br />

46/39<br />

128<br />

90<br />

45/39<br />

48/43<br />

48/43<br />

141<br />

120<br />

Rw/Rw+Ctr<br />

45/39<br />

49/44<br />

49/45<br />

171<br />

120<br />

Rw/Rw+Ctr<br />

43/36<br />

46/41<br />

46/41<br />

155<br />

120<br />

Rw/Rw+Ctr<br />

45/39<br />

49/44<br />

49/45<br />

171<br />

TE010<br />

140<br />

46/40<br />

49/44<br />

49/45<br />

191<br />

TE011<br />

140<br />

43/37<br />

46/41<br />

46/42<br />

175<br />

TE012<br />

140<br />

46/40<br />

49/44<br />

49/44<br />

191


FRL<br />

60 / 60 / 60<br />

FRL<br />

90 / 90 / 90<br />

FRL<br />

60 / 60 / 60<br />

STEEL FRAME EXTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 7.5mm Duratex TM<br />

Side 2<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 7.5mm Duratex TM<br />

Side 2<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

<strong>Fire</strong> rated from outside only<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 9mm Duragrid TM<br />

Side 2<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

<strong>Fire</strong> rated from outside only<br />

64<br />

42/36<br />

49/41<br />

50/41<br />

103.5<br />

64<br />

48/41<br />

56/50<br />

57/50<br />

135.5<br />

Timber batten can be substituted for steel<br />

64<br />

42/30<br />

49/37<br />

49/37<br />

105<br />

76 92<br />

Rw/Rw+Ctr<br />

42/35<br />

50/43<br />

51/43<br />

115.5<br />

76<br />

48/41<br />

57/51<br />

57/51<br />

147.5<br />

76<br />

44/33<br />

51/40<br />

51/40<br />

117<br />

43/36<br />

51/44<br />

51/44<br />

131.5<br />

92<br />

Rw/Rw+Ctr<br />

49/42<br />

57/51<br />

57/51<br />

163.5<br />

92<br />

Rw/Rw+Ctr<br />

46/36<br />

52/42<br />

52/42<br />

133<br />

SE001<br />

150<br />

45/37<br />

52/47<br />

52/47<br />

189.5<br />

SE002<br />

150<br />

52/44<br />

57/52<br />

57/52<br />

221.5<br />

SE003<br />

150<br />

50/42<br />

55/46<br />

55/46<br />

191<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

06 / EXTERIOR WALL INFORMATION<br />

79


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 06 / EXTERIOR WALL INFORMATION<br />

80<br />

STEEL FRAME EXTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

FRL<br />

90 / 90 / 90<br />

FRL<br />

60 / 60 / 60<br />

FRL<br />

90 / 90 / 90<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 9mm Duragrid TM<br />

Side 2<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

<strong>Fire</strong> rated from outside only<br />

Timber batten can be substituted for steel<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 9mm Duracom TM<br />

Side 2<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

<strong>Fire</strong> rated from outside only<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 9mm Duracom TM<br />

Side 2<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

<strong>Fire</strong> rated from outside only<br />

64<br />

50/40<br />

57/46<br />

57/46<br />

137<br />

64<br />

44/33<br />

49/37<br />

50/38<br />

105<br />

64<br />

51/41<br />

57/45<br />

57/45<br />

137<br />

76 92<br />

Rw/Rw+Ctr<br />

51/42<br />

58/48<br />

58/48<br />

149<br />

76<br />

45/35<br />

52/40<br />

52/40<br />

117<br />

76<br />

53/42<br />

58/46<br />

58/46<br />

149<br />

52/43<br />

59/49<br />

59/49<br />

165<br />

92<br />

Rw/Rw+Ctr<br />

47/37<br />

53/42<br />

53/42<br />

133<br />

92<br />

Rw/Rw+Ctr<br />

54/44<br />

59/48<br />

59/48<br />

165<br />

SE004<br />

150<br />

54/46<br />

60/53<br />

60/53<br />

223<br />

SE005<br />

150<br />

52/42<br />

56/46<br />

56/46<br />

191<br />

SE006<br />

150<br />

56/46<br />

59/51<br />

59/51<br />

223


FRL<br />

60 / 60 / 60<br />

FRL<br />

90 / 90 / 90<br />

FRL<br />

60 / 60 / 60<br />

STEEL FRAME EXTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 14mm Nuline TM Plus<br />

Side 2<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

<strong>Fire</strong> rated from outside only<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 14mm Nuline TM Plus<br />

Side 2<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

<strong>Fire</strong> rated from outside only<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 9mm Durascape TM<br />

Side 2<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

<strong>Fire</strong> rated from outside only<br />

64<br />

45/35<br />

50/38<br />

50/38<br />

110<br />

64<br />

52/40<br />

57/44<br />

57/44<br />

142<br />

64<br />

42/36<br />

50/42<br />

50/42<br />

105<br />

76 92<br />

Rw/Rw+Ctr<br />

47/36<br />

51/40<br />

51/40<br />

122<br />

76<br />

51/39<br />

58/45<br />

58/44<br />

154<br />

76<br />

42/36<br />

51/44<br />

51/44<br />

117<br />

46/36<br />

52/41<br />

52/41<br />

138<br />

92<br />

Rw/Rw+Ctr<br />

53/41<br />

58/46<br />

58/46<br />

170<br />

92<br />

Rw/Rw+Ctr<br />

43/36<br />

52/44<br />

52/45<br />

133<br />

SE007<br />

150<br />

50/40<br />

54/45<br />

54/45<br />

196<br />

SE008<br />

150<br />

56/45<br />

59/50<br />

59/50<br />

228<br />

SE009<br />

150<br />

45/38<br />

53/47<br />

53/48<br />

191<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

06 / EXTERIOR WALL INFORMATION<br />

81


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 06 / EXTERIOR WALL INFORMATION<br />

82<br />

STEEL FRAME EXTERIOR WALL SYSTEM<br />

SINGLE STUD<br />

FRL<br />

90 / 90 / 90<br />

FRL<br />

60 / 60 / 60<br />

FRL<br />

90 / 90 / 90<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 9mm Durascape TM<br />

Side 2<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

<strong>Fire</strong> rated from outside only<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 9mm Duragroove TM<br />

Side 2<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

<strong>Fire</strong> rated from outside only<br />

STEEL STUDS AT 600mm MAX CENTRES<br />

Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />

1 x 9mm Duragroove TM<br />

Side 2<br />

STUD DEPTH mm<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

WALL THICKNESS mm<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

<strong>Fire</strong> rated from outside only<br />

64<br />

48/41<br />

57/50<br />

57/51<br />

137<br />

64<br />

42/36<br />

50/42<br />

50/42<br />

105<br />

64<br />

48/41<br />

57/50<br />

57/51<br />

137<br />

76 92<br />

Rw/Rw+Ctr<br />

49/42<br />

57/51<br />

57/51<br />

149<br />

76<br />

42/36<br />

51/44<br />

51/44<br />

117<br />

76<br />

49/42<br />

57/51<br />

57/51<br />

149<br />

50/43<br />

57/51<br />

58/52<br />

165<br />

92<br />

Rw/Rw+Ctr<br />

43/36<br />

52/44<br />

52/45<br />

133<br />

92<br />

Rw/Rw+Ctr<br />

50/43<br />

57/51<br />

58/52<br />

165<br />

SE010<br />

150<br />

52/44<br />

58/53<br />

58/53<br />

223<br />

SE011<br />

150<br />

45/38<br />

53/47<br />

53/48<br />

191<br />

SE012<br />

150<br />

52/44<br />

58/53<br />

58/53<br />

223


TIMBER FRAME WITH ONE LAYER <strong>BGC</strong> WET AREA FIREBOARD<br />

60/60/60 BOUNDARY WALL<br />

SCREW FIXINGS FOR SOFT WOOD TIMBER FRAMING<br />

FRAMING<br />

Soft Wood Timber<br />

FIREBOARD THICKNESS<br />

16mm<br />

TIMBER FRAME WITH TWO LAYERS <strong>BGC</strong> WET AREA FIREBOARD<br />

90/90/90 BOUNDARY WALL<br />

INSTALLATION DETAILS<br />

EXTERIOR WALLS<br />

FASTENER SPACING<br />

2 Nails at 300mm max<br />

centres 1 screw at<br />

200mm max centres<br />

At each stud<br />

Nails at 150mm max<br />

centres screws at<br />

200mm max centres<br />

Nails at 150mm max<br />

centres screws at<br />

200mm max centres<br />

SCREW TYPE<br />

No 6 Type W<br />

SCREW FIXINGS FOR SOFT WOOD TIMBER FRAMING<br />

FRAMING<br />

Soft Wood Timber<br />

FIREBOARD THICKNESS<br />

16mm<br />

FIXING SPECIFICATIONS<br />

FIRST LAYER<br />

FASTENER SPACING<br />

Nails or Screws<br />

600mm max. centres<br />

Nails or Screws<br />

600mm max. centres<br />

Nails or Screws<br />

600mm max. centres<br />

in stagered pattern<br />

2 Nails 50mm apart at<br />

300mm max. centres<br />

1 screw at 200mm<br />

max. centres<br />

At Each Stud<br />

Nails at 150mm max.<br />

centres Screws at<br />

200mm max. centres<br />

Nails at 150mm<br />

max. centres Screws<br />

at 300mm max.<br />

centres<br />

SCREW TYPE<br />

No 6 Type W<br />

FIXING SPECIFICATIONS<br />

SECOND LAYER<br />

LOCATION<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints<br />

Corners & Openings<br />

SCREW LENGTH<br />

1ST LAYER<br />

45mm<br />

LOCATION<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints<br />

Corners & Openings<br />

SCREW LENGTH<br />

1ST LAYER<br />

45mm<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

06 / EXTERIOR WALL INFORMATION<br />

83


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 06 / EXTERIOR WALL INFORMATION<br />

84<br />

INSTALLATION DETAILS<br />

EXTERIOR WALLS<br />

STEEL FRAME WITH ONE LAYER <strong>BGC</strong> WET AREA FIREBOARD<br />

60/60/60 BOUNDARY WALL<br />

STEEL FRAME WITH TWO LAYERS <strong>BGC</strong> WET AREA FIREBOARD<br />

90/90/90 BOUNDARY WALL<br />

FIXING SPECIFICATIONS<br />

FASTENER SPACING<br />

300mm max. centres<br />

At Each Stud<br />

100mm max. centres<br />

300mm max.centres<br />

SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING<br />

FRAMING<br />

Lightweight Steel up to<br />

0.8mm<br />

Lightweight Steel 0.8mm<br />

to 1.6mm<br />

FIREBOARD THICKNESS<br />

16mm<br />

16mm<br />

SCREW TYPE<br />

No 6 Type S Needle Point<br />

No 6 Type D Drill Point<br />

FASTENER SPACING<br />

600mm max. centres<br />

600mm max. centres<br />

600mm max. centres<br />

300mm max. centres<br />

At Each Stud<br />

200mm max. centres<br />

300mm max.centres<br />

SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING<br />

FRAMING<br />

Lightweight Steel up to<br />

0.8mm<br />

Lightweight Steel 0.8mm<br />

to 1.6mm<br />

FIREBOARD THICKNESS<br />

16mm<br />

16mm<br />

SCREW TYPE<br />

No 6 Type S Needle Point<br />

No 6 Type D Drill Point<br />

LOCATION<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints<br />

Corners & Openings<br />

FIXING SPECIFICATIONS<br />

FIRST LAYER<br />

SECOND LAYER<br />

SCREW LENGTH<br />

1ST LAYER<br />

30mm<br />

32mm<br />

LOCATION<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints<br />

Centre of the Board<br />

Recessed Edges<br />

Butt Joints<br />

Corners & Openings<br />

SCREW LENGTH<br />

1ST LAYER 2ND LAYER<br />

30mm 45mm<br />

32mm<br />

45mm


FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FLOOR / CEILING<br />

TIMBER OR STEEL JOISTS<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

MIN CAVITY DEPTH OF 190mm<br />

Ceiling Lining 1 x 13mm <strong>BGC</strong> Plasterboard<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

MIN CAVITY DEPTH OF 190mm<br />

Ceiling Lining 2 x 13mm <strong>BGC</strong> Plasterboard<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

MIN CAVITY DEPTH OF 190mm<br />

Ceiling Lining 1 x 10mm <strong>BGC</strong> Ceilingboard<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

39/33<br />

40/36<br />

40/36<br />

Rw/Rw+Ctr<br />

41/35<br />

42/39<br />

42/39<br />

Rw/Rw+Ctr<br />

37/31<br />

39/35<br />

39/35<br />

C001<br />

C002<br />

C003<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

07 / CEILING INFORMATION<br />

85


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 07 / CEILING INFORMATION<br />

86<br />

FLOOR / CEILING<br />

TIMBER OR STEEL JOISTS<br />

FRL<br />

- / - / -<br />

FRL<br />

90 / 90 / 90<br />

FRL<br />

30 / 30 / 30<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

MIN CAVITY DEPTH OF 190mm<br />

Ceiling Lining 2 x 10mm <strong>BGC</strong> Soundboard TM<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

41/36<br />

42/39<br />

42/39<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

MIN CAVITY DEPTH OF 190mm<br />

Ceiling Lining 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Rw/Rw+Ctr<br />

43/38<br />

44/41<br />

44/41<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

MIN CAVITY DEPTH OF 190mm<br />

Ceiling Lining 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

40/35<br />

40/38<br />

40/38<br />

C004<br />

C005<br />

C018


FRL<br />

90 / 90 / 90<br />

FRL<br />

120 / 120 / 120<br />

FLOOR / CEILING<br />

TIMBER OR STEEL JOISTS<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

MIN CAVITY DEPTH OF 190mm<br />

Ceiling Lining 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

MIN CAVITY DEPTH OF 190mm<br />

Ceiling Lining 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

43/38<br />

44/41<br />

44/41<br />

Rw/Rw+Ctr<br />

45/40<br />

46/44<br />

46/44<br />

C006<br />

C007<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

07 / CEILING INFORMATION<br />

87


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 07 / CEILING INFORMATION<br />

88<br />

FLOOR / CEILING<br />

TIMBER OR STEEL JOISTS WITH FURRING CHANNELS TIMBER OR STEEL<br />

JOISTS WITH FURRING CHANNELS<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

WITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm<br />

Ceiling Lining 1 x 10mm <strong>BGC</strong> Ceilingboard<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

39/33<br />

42/38<br />

42/38<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

WITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm<br />

Ceiling Lining 1 x 13mm <strong>BGC</strong> Plasterboard<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

40/34<br />

43/39<br />

43/39<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

WITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm<br />

Ceiling Lining 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

(furring channel at 450mm max centres)<br />

Rw/Rw+Ctr<br />

40/33<br />

43/39<br />

43/39<br />

C010<br />

C011<br />

C012


FRL<br />

- / - / -<br />

FRL<br />

60 / 60 / 60<br />

FRL<br />

90 / 90 / 90<br />

FLOOR / CEILING<br />

TIMBER OR STEEL JOISTS WITH FURRING CHANNELS<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

WITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm<br />

Ceiling Lining 1 x 9mm <strong>BGC</strong> Duraliner TM<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

43/37<br />

45/41<br />

45/41<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

WITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm<br />

Ceiling Lining 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

43/38<br />

46/43<br />

46/43<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

WITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm<br />

Ceiling Lining 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

Rw/Rw+Ctr<br />

44/39<br />

47/44<br />

47/44<br />

C013<br />

C014<br />

C015<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

07 / CEILING INFORMATION<br />

89


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 07 / CEILING INFORMATION<br />

90<br />

FLOOR / CEILING<br />

TIMBER OR STEEL JOISTS WITH FURRING CHANNELS<br />

FRL<br />

90 / 90 / 90<br />

FRL<br />

120 / 120 / 120<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

WITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm<br />

Ceiling Lining 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

44/39<br />

47/44<br />

47/44<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

WITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm<br />

Ceiling Lining 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

46/41<br />

49/47<br />

49/47<br />

C016<br />

C017


FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FLOOR / CEILING<br />

TIMBER OR STEEL JOISTS WITH FURRING CHANNELS<br />

AND ACOUSTIC RESILIENT MOUNTS<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />

MIN CAVITY DEPTH OF 232mm<br />

Ceiling Lining 1 x 13mm <strong>BGC</strong> Plasterboard<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />

MIN CAVITY DEPTH OF 232mm<br />

Ceiling Lining 1 x 10mm <strong>BGC</strong> Soundboard TM<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />

MIN CAVITY DEPTH OF 232mm<br />

Ceiling Lining 2 x 10mm <strong>BGC</strong> Soundboard TM<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

42/34<br />

49/42<br />

50/43<br />

Rw/Rw+Ctr<br />

42/34<br />

49/42<br />

50/43<br />

Rw/Rw+Ctr<br />

47/38<br />

54/48<br />

55/49<br />

C020<br />

C021<br />

C022<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

07 / CEILING INFORMATION<br />

91


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 07 / CEILING INFORMATION<br />

92<br />

FLOOR / CEILING<br />

TIMBER OR STEEL JOISTS WITH FURRING CHANNELS<br />

AND ACOUSTIC RESILIENT MOUNTS<br />

FRL<br />

90 / 90 / 90<br />

FRL<br />

60 / 60 / 60<br />

FRL<br />

90 / 90 / 90<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />

MIN CAVITY DEPTH OF 232mm<br />

Ceiling Lining 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />

MIN CAVITY DEPTH OF 232mm<br />

Ceiling Lining 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />

WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />

MIN CAVITY DEPTH OF 232mm<br />

Ceiling Lining 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

48/39<br />

55/49<br />

56/50<br />

Rw/Rw+Ctr<br />

48/39<br />

55/49<br />

56/50<br />

Rw/Rw+Ctr<br />

49/41<br />

56/49<br />

56/50<br />

C023<br />

C024<br />

C025


FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

ROOF / CEILING<br />

TIMBER TRUSSES<br />

PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />

OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />

BATTENS MAX JOIST OR TRUSS SPACING AT 600mm<br />

Ceiling Lining 1 x 10mm <strong>BGC</strong> Soundboard TM<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />

OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />

BATTENS MAX JOIST OR TRUSS SPACING AT 600mm<br />

Ceiling Lining 2 x 10mm <strong>BGC</strong> Soundboard TM<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />

OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />

BATTENS MAX JOIST OR TRUSS SPACING AT 600mm<br />

Ceiling Lining 1 x 13mm <strong>BGC</strong> Plasterboard<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

-<br />

41/32<br />

42/32<br />

Rw/Rw+Ctr<br />

-<br />

45/36<br />

45/37<br />

Rw/Rw+Ctr<br />

-<br />

41/32<br />

42/32<br />

C030<br />

C031<br />

C032<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

07 / CEILING INFORMATION<br />

93


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 07 / CEILING INFORMATION<br />

94<br />

ROOF / CEILING<br />

TIMBER TRUSSES<br />

FRL<br />

- / - / -<br />

FRL<br />

60 / 60 / 60<br />

FRL<br />

90 / 90 / 90<br />

PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />

OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />

BATTENS MAX JOIST OR TRUSS SPACING AT 600mm<br />

Ceiling Lining 1 x 13mm <strong>BGC</strong> Soundboard TM<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

-<br />

42/34<br />

43/34<br />

PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />

OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />

BATTENS MAX JOIST OR TRUSS SPACING AT 600mm<br />

Ceiling Lining 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

-<br />

45/37<br />

46/38<br />

PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />

OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />

BATTENS MAX JOIST OR TRUSS SPACING AT 600mm<br />

Ceiling Lining 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

-<br />

46/38<br />

47/39<br />

C033<br />

C037<br />

C034


FRL<br />

90 / 90 / 90<br />

FRL<br />

120 / 120 / 120<br />

ROOF / CEILING<br />

TIMBER TRUSSES<br />

PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING OR<br />

SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS<br />

MAX JOIST OR TRUSS SPACING AT 600mm<br />

Ceiling Lining 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

-<br />

46/38<br />

46/38<br />

PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />

OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />

BATTENS MAX JOIST OR TRUSS SPACING AT 600mm<br />

Ceiling Lining 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

-<br />

48/41<br />

48/40<br />

C035<br />

C036<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

07 / CEILING INFORMATION<br />

95


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 07 / CEILING INFORMATION<br />

96<br />

ROOF / CEILING<br />

FURRING CHANNELS<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />

OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />

BATTENS WITH FURRING CHANNELS<br />

Ceiling Lining 1 x 10mm <strong>BGC</strong> Plasterboard<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

PITCHED TILED ROOF WITH OR WITHOUT350g/m 2 SARKING<br />

OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />

BATTENS WITH FURRING CHANNELS<br />

Ceiling Lining 1 x 10mm <strong>BGC</strong> Soundboard TM<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />

OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />

BATTENS WITH FURRING CHANNELS<br />

Ceiling Lining 1 x 13mm <strong>BGC</strong> Soundboard TM<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

-<br />

40/31<br />

40/31<br />

Rw/Rw+Ctr<br />

-<br />

43/34<br />

43/34<br />

Rw/Rw+Ctr<br />

-<br />

44/37<br />

44/36<br />

C040<br />

C041<br />

C042


FRL<br />

- / - / -<br />

FRL<br />

90 / 90 / 90<br />

FRL<br />

90 / 90 / 90<br />

ROOF / CEILING<br />

FURRING CHANNELS<br />

PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />

OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />

BATTENS WITH FURRING CHANNELS<br />

Ceiling Lining 1 x 6mm <strong>BGC</strong> Duraliner TM<br />

(Furring channels at 450 max centres)<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />

OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />

BATTENS WITH FURRING CHANNELS<br />

Ceiling Lining 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />

OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />

BATTENS WITH FURRING CHANNELS<br />

Ceiling Lining 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

-<br />

41/32<br />

41/32<br />

Rw/Rw+Ctr<br />

-<br />

48/41<br />

48/41<br />

Rw/Rw+Ctr<br />

-<br />

48/41<br />

48/41<br />

C043<br />

C044<br />

C045<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

07 / CEILING INFORMATION<br />

97


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 07 / CEILING INFORMATION<br />

98<br />

ROOF / CEILING<br />

FURRING CHANNELS<br />

FRL<br />

120 / 120 / 120<br />

PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING OR<br />

SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS<br />

WITH FURRING CHANNELS<br />

Ceiling Lining 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

-<br />

50/42<br />

51/43<br />

C046


FRL<br />

- / - / -<br />

FRL<br />

- / - / -<br />

FRL<br />

90 / 90 / 90<br />

ROOF / CEILING<br />

FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />

PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING OR<br />

SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS<br />

WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />

Ceiling Lining 1 x 10mm <strong>BGC</strong> Soundboard TM<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING OR<br />

SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS<br />

WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />

Ceiling Lining 2 x 10mm <strong>BGC</strong> Soundboard TM<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING OR<br />

SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS<br />

WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />

Ceiling Lining 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />

1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

-<br />

44/35<br />

45/35<br />

Rw/Rw+Ctr<br />

-<br />

49/38<br />

50/39<br />

Rw/Rw+Ctr<br />

-<br />

50/40<br />

51/40<br />

C050<br />

C051<br />

C052<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

07 / CEILING INFORMATION<br />

99


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 07 / CEILING INFORMATION<br />

100<br />

ROOF / CEILING<br />

FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />

FRL<br />

90 / 90 / 90<br />

FRL<br />

120 / 120 / 120<br />

PITCHED TILED ROOF WITH OR WITHOUT 350g/m SARKING OR<br />

SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS<br />

WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />

Ceiling Lining 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

PITCHED TILED ROOF WITH OR WITHOUT 350g/m SARKING OR<br />

SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS<br />

WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />

Ceiling Lining 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

CAVITY INFILL<br />

Nil<br />

9kg - 50mm Polyester<br />

30kg - 75mm Polyester<br />

Rw/Rw+Ctr<br />

-<br />

50/40<br />

52/41<br />

Rw/Rw+Ctr<br />

-<br />

53/43<br />

54/44<br />

C053<br />

C054


STEEL OR TIMBER WITH ONE OR TWO LAYERS OF <strong>BGC</strong> FIREBOARD –<br />

NAIL OR SCREW FIXING<br />

Note: Refer to page 10 for screw lengths.<br />

NOTE:<br />

One layer systems<br />

to be fixed as per<br />

2nd layer. Butt joints<br />

between framing are to<br />

be fully back blocked<br />

<strong>and</strong> fixed with<br />

laminating screws.<br />

INSTALLATION DETAILS<br />

CEILING<br />

FIXING SPECIFICATIONS ONE OR TWO<br />

LAYERS OF <strong>BGC</strong> FIREBOARD-<br />

NAIL OR SCREW FIXING<br />

FIRST LAYER<br />

FASTENER SPACING LOCATION<br />

Each framing member at<br />

10 to 16mm from sheet<br />

edges <strong>and</strong> at 200mm<br />

max centres<br />

150mm max centres<br />

150mm max centres<br />

Cornice finish - 200mm<br />

max centres. Set finish -<br />

150mm max centres<br />

Framing at 450mm -<br />

150mm max centres<br />

Framing at 600mm -<br />

within 50mm of centre<br />

line between framing<br />

& fix to ist layer with<br />

laminating screws at<br />

200mm max centres<br />

150mm max centres<br />

Cornice finish - 200mm<br />

max centres. Set finish -<br />

150mm max centres<br />

SECOND LAYER<br />

Centre of the Board<br />

Butt Joints<br />

Openings<br />

Sheet ends<br />

Butt Joints<br />

Openings<br />

Sheet ends<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

07 / CEILING INFORMATION<br />

101


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 07 / CEILING INFORMATION<br />

102<br />

INSTALLATION DETAILS<br />

CEILING<br />

STEEL OR TIMBER WITH THREE LAYERS OF <strong>BGC</strong> FIREBOARD –<br />

NAIL OR SCREW FIXING<br />

FIXING SPECIFICATIONS THREE OF<br />

<strong>BGC</strong> FIREBOARD - NAIL OR SCREW FIXING<br />

FIRST LAYER<br />

FASTENER SPACING<br />

LOCATION<br />

150mm max centres<br />

150mm max centres<br />

Cornice finish -<br />

200mm max centres<br />

Set finish - 150mm<br />

max centres<br />

Each framing member<br />

at 10 to 16mm from sheet<br />

edges <strong>and</strong> at 200mm<br />

max centres<br />

150mm max centres<br />

150mm max centres<br />

Cornice finish -<br />

200mm max centres<br />

Set finish - 150mm<br />

max centres<br />

Each framing member at<br />

10 to 16mm from sheet<br />

edges <strong>and</strong> at 200mm<br />

max centres<br />

Within 50mm of centre<br />

line between framing &<br />

fix to previous layer with<br />

laminating screws at<br />

200mm max centres<br />

150mm max centres<br />

Cornice finish - 200mm<br />

max centres. Set finish -<br />

150mm max centres<br />

SECOND LAYER<br />

THIRD LAYER<br />

Centre of the Board<br />

Butt Joints<br />

Openings<br />

Sheet ends<br />

Centre of the Board<br />

Butt Joints<br />

Openings<br />

Sheet ends<br />

Centre of the Board<br />

Butt Joints<br />

Openings<br />

Sheet ends<br />

Note: Refer to page 10 for screw lengths.


STEEL OR TIMBER WITH ONE OR TWO LAYERS OF <strong>BGC</strong> FIREBOARD –<br />

NAIL OR SCREW FIXING<br />

• Steel angle fixed to the soffit or wall junction.<br />

• Universal Encasement Clips friction fitted<br />

to the remaining column/beam flanges.<br />

• Wall Furring Track is held in the back tongue of the clip.<br />

• Noggings at each end of the column/beam<br />

<strong>and</strong> behind plasterboard butt joins in<br />

single layer systems.<br />

FRL SYSTEM NO. LININGS<br />

30/-/-<br />

60/-/-<br />

90/-/-<br />

90/-/-<br />

120/-/-<br />

180/-/-<br />

CB01<br />

CB02<br />

CB03<br />

CB04<br />

CB05<br />

CB06<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

4 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

COLUMN OR BEAM<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

08 / COLUMNS / BEAMS / PENETRATIONS<br />

103


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

COLUMN OR BEAM<br />

STEEL OR TIMBER WITH ONE OR TWO LAYERS OF <strong>BGC</strong> FIREBOARD –<br />

NAIL OR SCREW FIXING<br />

FRL SYSTEM NO. LININGS<br />

08 / COLUMNS / BEAMS / PENETRATIONS 104<br />

30/-/-<br />

60/-/-<br />

90/-/-<br />

120/-/-<br />

180/-/-<br />

CB07<br />

CB08<br />

CB09<br />

CB10<br />

CB11<br />

1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />

2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />

4 x 16mm <strong>BGC</strong> <strong>Fire</strong>board


Special design considerations apply to<br />

<strong>Fire</strong> Rated walls in order to maintain the<br />

<strong>Fire</strong> Rating (FRL) of a system.<br />

• Electrical penetrations must not be placed<br />

back to back or more than one penetration<br />

per stud spacing.<br />

• Proprietary <strong>Fire</strong> Rated switch boxes are<br />

to be used.<br />

• <strong>BGC</strong> Plasterboard recommends the use of<br />

min R1.5 insulation batt be included in the<br />

wall cavity to assist in maintaining acoustic<br />

integrity.<br />

• All penetrations shall be sealed with an<br />

approved AS/NZS 1530.4 <strong>Fire</strong> Rated mastic<br />

filler. See Figure 1.<br />

• Where plumbing penetrations are required -<br />

all pipework must be self supporting.<br />

FIGURE 1<br />

Pipe Penetration Through Wall (copper)<br />

Backing rod<br />

(not fire rated)<br />

<strong>BGC</strong><br />

<strong>Fire</strong>board<br />

FIGURE 2<br />

Pipe Penetration Through Ceiling<br />

6mm<br />

Wire mesh<br />

flame guard<br />

n<br />

15mm Mi<br />

100mm Max<br />

(copper) pipe<br />

<strong>Fire</strong> rated mastic filler<br />

<strong>Fire</strong> rated<br />

mastic filler<br />

Pipewor<br />

(152mm<br />

max diam<br />

20mm<br />

I.B.S. Fyreguard<br />

foam 50 x 20<br />

<strong>BGC</strong> <strong>Fire</strong>board<br />

k<br />

)<br />

PENETRATIONS<br />

TYPICAL<br />

FIGURE 3<br />

Control Joint - Wall Frame Double Layer<br />

<strong>Fire</strong> rated mastic<br />

Min depth 15mm<br />

Rondo P53<br />

control joint<br />

typical<br />

FIGURE 4<br />

Control Joint - Wall Frame Single Layer<br />

<strong>Fire</strong> rated mastic<br />

Min depth 15mm<br />

Rondo P53<br />

control joint<br />

typical<br />

FIGURE 5<br />

Control Joint - Wall Frame<br />

<strong>Fire</strong> rated mastic<br />

Min depth 15mm<br />

FIGURE 6<br />

Electrical Penetration Through Wall (Typical)<br />

Note: Do not place switch boxes back to back.<br />

Proprietery fire<br />

rated switch box<br />

installed to<br />

manufacturers<br />

recommendations<br />

<strong>Fire</strong> rated mastic<br />

15 mm<br />

15 mm<br />

10 mm<br />

<strong>BGC</strong> Fibre Cement sheeting<br />

<strong>BGC</strong> <strong>Fire</strong>board<br />

Backing rod<br />

20 mm min<br />

Top <strong>and</strong><br />

bottom track is<br />

discontinuous<br />

Additional stud<br />

required at control joint<br />

<strong>BGC</strong> <strong>Fire</strong>board<br />

Backing rod<br />

Backing rod<br />

15 mm min<br />

Top <strong>and</strong><br />

bottom track is<br />

discontinuous<br />

Additional stud<br />

required at control joint<br />

<strong>BGC</strong> <strong>Fire</strong>board<br />

Top <strong>and</strong><br />

bottom track is<br />

discontinuous<br />

Additional stud<br />

required at control joint<br />

<strong>BGC</strong> <strong>Fire</strong>board<br />

<strong>Fire</strong> rated mastic<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

08 / COLUMNS / BEAMS / PENETRATIONS<br />

105


<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 08 / COLUMNS / BEAMS / PENETRATIONS<br />

106<br />

PENETRATIONS<br />

TYPICAL<br />

FIRE PENETRATIONS FOR SINGLE, DOUBLE & STAGGERED<br />

STUD WALLS - ELEVATION


WARRANTY<br />

We warrant that our products are free from defects caused by faulty<br />

manufacture or materials for a period of 15 years from the date of<br />

purchase. If you acquire any defective products, we will repair or<br />

replace them, supply equivalent replacement products or refund the<br />

purchase price within 30 days of receiving a valid claim subject to<br />

product inspection <strong>and</strong> confirmation of the existence of a defect by<br />

<strong>BGC</strong>. We will bear the cost of any such repair, replacement or refund.<br />

This warranty is given by:<br />

<strong>BGC</strong> Plasterboard Pty Ltd<br />

Ground Floor, 290 Bushmead Rd, Hazelmere, WA 6055<br />

Phone: (08) 9374 2900 Fax: (08) 9374 2901<br />

To claim under this warranty, you must provide proof of purchase as<br />

a consumer <strong>and</strong> make a written claim (including any costs of claiming)<br />

to us at the address specified above within 30 days after the defect was<br />

reasonably apparent, or if the defect was reasonably apparent prior to<br />

installation, the claim must be made prior to installation. You may not<br />

claim under this warranty for loss or damage caused by:<br />

• faulty or incorrect installation by non-<strong>BGC</strong> installers (<strong>BGC</strong>’s installation<br />

procedures are at www.bgc.com.au/plasterboard);<br />

• failure to comply with the Building Code of Australia or any applicable<br />

legislation, regulations approvals <strong>and</strong> st<strong>and</strong>ards;<br />

• products not made or supplied by <strong>BGC</strong>;<br />

• abnormal use of the product; or<br />

• normal wear <strong>and</strong> tear.<br />

The benefits available under this warranty are in addition to other rights<br />

<strong>and</strong> remedies of the consumer under the law. Our goods come with<br />

guarantees that cannot be excluded under the Australian Consumer<br />

Law. You are entitled to a replacement or refund for a major failure <strong>and</strong><br />

for compensation for any other reasonably foreseeable loss or damage.<br />

You are also entitled to have the goods repaired or replaced if the goods<br />

fail to be of acceptable quality <strong>and</strong> the failure does not amount to a<br />

major failure.<br />

<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />

107


CONTACT<br />

ADELAIDE<br />

TELEPHONE<br />

08 8250 4962<br />

BRISBANE<br />

TELEPHONE<br />

07 2371 1711<br />

MELBOURNE<br />

TELEPHONE<br />

03 9392 9444<br />

PERTH<br />

TELEPHONE<br />

08 9334 4900<br />

SYDNEY<br />

TELEPHONE<br />

02 9771 9660<br />

NEW ZEALAND<br />

TELEPHONE<br />

0011 64 9264 1457<br />

Australian Owned & Manufactured<br />

www.bgc.com.au/plasterboard www.bgcinnovadesign.com.au

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!