Fire and Acoustic Guide - BGC
Fire and Acoustic Guide - BGC
Fire and Acoustic Guide - BGC
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
MARCH / 2013<br />
<strong>BGC</strong> PLASTERBOARD<br />
FIRE & ACOUSTIC<br />
GUIDE<br />
Australian Owned & Manufactured<br />
www.bgc.com.au/plasterboard www.bgcinnovadesign.com.au
The <strong>BGC</strong> Plasterboard <strong>Fire</strong> <strong>and</strong> <strong>Acoustic</strong> <strong>Guide</strong> has been<br />
designed to assist architects, specifiers, designers, builders<br />
<strong>and</strong> contractors in the selection of the correct system for<br />
projects when fire <strong>and</strong> acoustic properties are required.<br />
Each of the systems in this <strong>Guide</strong> has been given a<br />
unique system number to help with ease of identification.<br />
A quick reference guide to these numbers is noted further<br />
in the <strong>Guide</strong>.<br />
The data contained in this <strong>Guide</strong> meets all Australian<br />
st<strong>and</strong>ards <strong>and</strong> is correct at the time of publication.<br />
SAFETY<br />
In normal circumstances there are no known<br />
health hazards when using or applying<br />
plasterboard. However, <strong>BGC</strong> Plasterboard<br />
recommends that the following precautions<br />
are followed.<br />
Avoid creating dust when h<strong>and</strong>ling <strong>BGC</strong><br />
Plasterboard or plasterboard products. <strong>BGC</strong><br />
Plasterboard suggests that P1 or P2 particulate<br />
respirator (dust mask), which comply with<br />
Australian <strong>and</strong> New Zeal<strong>and</strong> St<strong>and</strong>ard AS/NZS<br />
1715: Selection, Use <strong>and</strong> Maintenance of<br />
Respiratory Protective Devices, <strong>and</strong> Australian<br />
<strong>and</strong> New Zeal<strong>and</strong> St<strong>and</strong>ard AS/NZS 1716:<br />
Respiratory Protective Devices when Exposed<br />
to Dust), be used at all times.<br />
FIRST AID<br />
Eyes Flush with clean water for 15 minutes.<br />
Seek medical attention if irritation persists.<br />
Skin Wash with mild soap <strong>and</strong> water.<br />
Seek medical attention if irritation persists.<br />
Inhalation Drink plenty of water.<br />
Seek medical attention.<br />
Material Safety Data Sheets for <strong>BGC</strong> Plasterboard<br />
<strong>and</strong> <strong>BGC</strong> Fibre Cement products are available at<br />
any <strong>BGC</strong> state office or the <strong>BGC</strong> website<br />
www.bgc.com.au/plasterboard<br />
www.bgcinnovadesign.com.au<br />
INTRODUCTION TO <strong>BGC</strong> PLASTERBOARD<br />
FIRE AND ACOUSTIC GUIDE<br />
CERTIFICATION DETAILS<br />
All systems in the <strong>BGC</strong> Plasterboard <strong>Fire</strong> <strong>and</strong><br />
<strong>Acoustic</strong> <strong>Guide</strong> have been assessed to meet<br />
all requirements of Australian St<strong>and</strong>ards <strong>and</strong><br />
the Building Code of Australia.<br />
<strong>Acoustic</strong> testing has been carried out to<br />
Australian St<strong>and</strong>ards.<br />
The acoustic testing has been carried out by<br />
the following institutions:<br />
• Royal Melbourne Institute of Technology (RMIT)<br />
• CSIRO<br />
The fire testing has been carried out to Australian<br />
St<strong>and</strong>ard AS1530 – part 4 ‘<strong>Fire</strong> <strong>and</strong> Resistance<br />
Tests of Elements of Building Construction’ <strong>and</strong><br />
were carried out by:<br />
• CSIRO<br />
• Exova Warringtonfire Aus Pty Ltd.<br />
<strong>Fire</strong> <strong>and</strong> acoustic test reports <strong>and</strong> opinions can<br />
be obtained upon request. The systems detailed<br />
in this <strong>Guide</strong> <strong>and</strong> their warranties are only valid if<br />
constructed in accordance with <strong>BGC</strong> Plasterboard<br />
or <strong>BGC</strong> Fibre Cement installation methods <strong>and</strong><br />
using only <strong>BGC</strong> Plasterboard or <strong>BGC</strong> Fibre<br />
Cement products.<br />
<strong>BGC</strong> manufactures plasterboard <strong>and</strong> fibre cement<br />
products under the rigorous Quality Management<br />
System of the International St<strong>and</strong>ard ISO 9001:2008<br />
<strong>and</strong> is the holder of Licence Agreement numbers<br />
QEC 2955/13 <strong>and</strong> QEC 29633.<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
01 / GENERAL INFORMATION<br />
1
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 01 / GENERAL INFORMATION<br />
2<br />
<strong>BGC</strong> PRODUCTS<br />
<strong>BGC</strong> PLASTERBOARD<br />
PRODUCT &<br />
THICKNESS mm<br />
PLASTERBOARD<br />
10mm<br />
PLASTERBOARD<br />
13mm<br />
CEILINGBOARD<br />
13mm<br />
WATER RESISTANT<br />
PLASTERBOARD 10mm<br />
WATER RESISTANT<br />
PLASTERBOARD 13mm<br />
FIREBOARD<br />
13mm<br />
FIREBOARD<br />
16mm<br />
CURVEBOARD TM<br />
6.5mm<br />
SOUNDBOARD TM<br />
10mm<br />
SOUNDBOARD TM<br />
13mm<br />
WET AREA FIREBOARD<br />
13mm<br />
WET AREA FIREBOARD<br />
16mm<br />
IMPACTBOARD<br />
13mm<br />
<strong>BGC</strong> ENVIROBOARD<br />
COMMERCIAL<br />
<strong>BGC</strong> ENVIROBOARD<br />
ULTIMATE<br />
WEIGHT<br />
KG/M²<br />
7.00<br />
9.00<br />
7.20<br />
7.80<br />
9.40<br />
10.60<br />
12.70<br />
4.20<br />
9.00<br />
12.50<br />
10.60<br />
12.60<br />
11.50<br />
9.50<br />
10.60<br />
COMPOUNDS<br />
PRODUCT<br />
Stud Adhesive<br />
Stud Adhesive<br />
Multi Purpose Joint Compound<br />
Multi Purpose Joint Compound<br />
Water Resistant Taping Cement<br />
Water Resistant Taping Cement<br />
Lightweight All Purpose Compound<br />
Top Coat<br />
Base Coat 45<br />
Base Coat 60<br />
Base Coat 60<br />
Base Coat 60<br />
Base Coat 90<br />
Cornice Cement 45<br />
Cornice Cement 60<br />
Cornice Cement 60<br />
Cornice Cement 60<br />
Cornice Cement 90<br />
Masonry Adhesive<br />
Back Blocking Cement<br />
Exterior <strong>and</strong> Wet Area Base Coat<br />
Exterior <strong>and</strong> Wet Area Top Coat<br />
Fibreglass Tape<br />
Fibreglass Tape<br />
WIDTH<br />
mm<br />
1200<br />
1350<br />
1200<br />
1350<br />
1200<br />
1350<br />
1200<br />
1350<br />
1200<br />
1350<br />
1200<br />
1200<br />
1200<br />
1200<br />
1350<br />
1200<br />
1200<br />
1200<br />
1200<br />
1200<br />
1200<br />
LENGTH mm<br />
2400 2700 3000 3600 4200 4800 5400 6000<br />
x x x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x x x x x<br />
x<br />
BUCKET/BAG SIZE<br />
1.25kg<br />
5.2kg<br />
6kg<br />
20kg<br />
1.65kg<br />
6.4kg<br />
15kg<br />
20kg<br />
20kg<br />
5kg<br />
10kg<br />
20kg<br />
20kg<br />
20kg<br />
5kg<br />
10kg<br />
20kg<br />
20kg<br />
20kg<br />
20kg<br />
12kg<br />
13kg<br />
50mm x 20m<br />
50mm x 90m<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x
PRODUCT &<br />
THICKNESS mm<br />
DURASHEET TM 4.5mm<br />
DURASHEET TM 6.0mm<br />
DURAPLANK TM<br />
7.5MM SMOOTH AND<br />
WOODGRAIN<br />
DURAPLANK TM 7.5mm<br />
RUSTICATED<br />
NULINE TM PLUS 14.0mm<br />
DURATEX TM 7.5mm<br />
DURATEX TM 9.0mm<br />
DURALATTICE TM 6.0mm<br />
DURAGRID TM 9.0mm<br />
DURACOM TM 9.0mm<br />
DURACOM TM 12.0mm<br />
DURASCAPE TM 9.0mm<br />
DURAGROOVE TM 9.0mm<br />
COMPRESSED 15.0mm<br />
COMPRESSED 18.0mm<br />
COMPRESSED 24.0mm<br />
DURALINER TM 6.0mm<br />
DURALINER TM 9.0mm<br />
DURALINER TM 12.0mm<br />
DURALUX TM 4.5mm<br />
DURALUX TM 6.0mm<br />
*DURALUX TM 9.0mm<br />
CTU 6.0mm<br />
VCU 5.0mm<br />
STONESHEET TM 9.0mm<br />
* Available only in<br />
Queensl<strong>and</strong><br />
WEIGHT<br />
KG/M²<br />
7.58<br />
10.00<br />
2.90<br />
3.80<br />
2.50<br />
4.83<br />
4.13<br />
12.5<br />
15.38<br />
7.69<br />
11.70<br />
16.95<br />
22.73<br />
12.50<br />
12.50<br />
28.57<br />
34.48<br />
47.62<br />
10.00<br />
15.38<br />
19.00<br />
7.4<br />
9.52<br />
15<br />
9.52<br />
8.33<br />
15.38<br />
WIDTH<br />
mm<br />
1200<br />
900<br />
750<br />
600<br />
450<br />
1200<br />
900<br />
300<br />
230<br />
205<br />
205<br />
175<br />
1200<br />
900<br />
1200<br />
1200<br />
900<br />
2990<br />
1190<br />
890<br />
590<br />
1200<br />
900<br />
1200<br />
1200<br />
900<br />
1200<br />
1200<br />
900<br />
1200<br />
900<br />
1200<br />
900<br />
1200<br />
1350<br />
1200<br />
1350<br />
1200<br />
1200<br />
900<br />
1200<br />
900<br />
1200<br />
1200<br />
900<br />
900<br />
1200<br />
1190 1200 1500 1790 1800 2100 2390 2400 2440 2450 2700 2725 2750 3000 3600 4200 4800 5400 6000<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
LENGTH mm<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
<strong>BGC</strong> PRODUCTS<br />
<strong>BGC</strong> FIBRE CEMENT<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
x<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
01 / GENERAL INFORMATION<br />
3
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 01 / GENERAL INFORMATION<br />
4<br />
QUICK REFERENCE GUIDE<br />
STEEL FRAME - SINGLE STUD<br />
SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER<br />
1 x 10mm <strong>BGC</strong> Plasterboard 1 x 10mm <strong>BGC</strong> Plasterboard -/-/- S001 27<br />
1 x 13mm <strong>BGC</strong> Plasterboard 1 x 13mm <strong>BGC</strong> Plasterboard -/-/- S002 27<br />
2 x 13mm <strong>BGC</strong> Plasterboard 1 x 13mm <strong>BGC</strong> Plasterboard -/-/- S003 27<br />
2 x 13mm <strong>BGC</strong> Plasterboard 2 x 13mm <strong>BGC</strong> Plasterboard -/-/- S005 28<br />
1 x 10mm <strong>BGC</strong> Soundboard TM 1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- S006 28<br />
1 x 13mm <strong>BGC</strong> Soundboard TM 1 x 13mm <strong>BGC</strong> Soundboard TM -/-/- S007 28<br />
2 x 10mm <strong>BGC</strong> Soundboard TM 1 x 10mm <strong>BGC</strong> WR Plasterboard -/-/- S009 29<br />
2 x 10mm <strong>BGC</strong> Soundboard TM 2 x 10mm <strong>BGC</strong> Soundboard TM -/-/- S010 29<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 S011 29<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
1 x 10mm <strong>BGC</strong> Plasterboard 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 S012 30<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 S018 30<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 60/60/60 S019 30<br />
2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 S021 31<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 90/90/90 S023 31<br />
3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board - /120/120 S025 31<br />
3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/180/180 S026 32<br />
1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- S027 32<br />
1 x 9mm <strong>BGC</strong> Duraliner TM 1 x 9mm <strong>BGC</strong> Duraliner TM -/-/- S028 32<br />
1 x 12mm <strong>BGC</strong> Duraliner TM 1 x 12mm <strong>BGC</strong> Duraliner TM -/-/- S029 33<br />
1 x 10mm <strong>BGC</strong> Soundboard TM 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- S031 33<br />
1 x 13mm <strong>BGC</strong> Plasterboard 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- S033 33<br />
1 x 13mm <strong>BGC</strong> Plasterboard 1 x 9mm <strong>BGC</strong> Duraliner TM -/-/- S034 34<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- S035 34<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs) 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />
1 x 9mm <strong>BGC</strong> Duraliner TM 1 x 9mm <strong>BGC</strong> Duraliner TM -/60/60 S041 34<br />
1 x 9mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 9mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 S043 35<br />
2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board -/180/180 S044 35<br />
----- 3 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board -/120/120 120/120/120 S045 36<br />
----- 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 S046 36<br />
----- 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 120/120/120 - S048 36<br />
QUICK REFERENCE GUIDE<br />
STEEL FRAME - STAGGERED STUD<br />
SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER<br />
1 x 10mm <strong>BGC</strong> Plasterboard 1 x 10mm <strong>BGC</strong> Plasterboard -/-/- SS001 37<br />
1 x 13mm <strong>BGC</strong> Plasterboard 1 x 13mm <strong>BGC</strong> Plasterboard -/-/- SS002 37<br />
1 x 10mm <strong>BGC</strong> Soundboard TM 1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- SS006 37<br />
1 x 13mm <strong>BGC</strong> Soundboard TM 1 x 13mm <strong>BGC</strong> Soundboard TM -/-/- SS007 38<br />
2 x 10mm <strong>BGC</strong> Soundboard TM 2 x 10mm <strong>BGC</strong> Soundboard TM -/-/- SS010 38<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 SS011 38<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
1 x 13mm <strong>BGC</strong> Plasterboard 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 SS014 39<br />
2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 SS018 39<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 SS019 39<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 SS020 40<br />
2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 SS021 40<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 SS023 40<br />
3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/180/180 SS026 41<br />
1 x 9mm Duraliner TM 1 x 9mm <strong>BGC</strong> Duraliner TM -/-/- SS028 41<br />
2 x 10mm <strong>BGC</strong> Soundboard TM 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- SS032 41<br />
1 x 13mm <strong>BGC</strong> Plasterboard 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- SS033 42<br />
1 x 13mm <strong>BGC</strong> Plasterboard 1 x 9mm <strong>BGC</strong> Duraliner TM -/-/- SS034 42<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- SS035 42<br />
1 x 9mm <strong>BGC</strong> Duraliner TM 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/-/- SS036 43<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs) 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />
1 x 9mm <strong>BGC</strong> Duraliner TM 1 x 9mm <strong>BGC</strong> Duraliner TM -/60/60 SS041 43<br />
1 x 9mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 9mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 SS043 43
SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER<br />
1 x 10mm <strong>BGC</strong> Plasterboard 1 x 10mm <strong>BGC</strong> Plasterboard -/-/- SD001 44<br />
1 x 13mm <strong>BGC</strong> Plasterboard 1 x 13mm <strong>BGC</strong> Plasterboard -/-/- SD002 44<br />
1 x 10mm <strong>BGC</strong> Soundboard TM 1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- SD006 44<br />
1 x 13mm <strong>BGC</strong> Soundboard TM 1 x 13mm <strong>BGC</strong> Soundboard TM -/-/- SD007 45<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 SD011 45<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs) 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />
SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER<br />
1 x 10mm <strong>BGC</strong> Plasterboard 1 x 10mm <strong>BGC</strong> Plasterboard -/-/- T001 55<br />
1 x 13mm <strong>BGC</strong> Plasterboard 1 x 13mm <strong>BGC</strong> Plasterboard -/-/- T002 55<br />
2 x 10mm <strong>BGC</strong> Plasterboard 2 x 10mm <strong>BGC</strong> Plasterboard -/-/- T004 55<br />
2 x 13mm <strong>BGC</strong> Plasterboard 2 x 13mm <strong>BGC</strong> Plasterboard -/-/- T005 56<br />
1 x 10mm <strong>BGC</strong> Soundboard TM 1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- T006 56<br />
1 x 13mm <strong>BGC</strong> Soundboard TM 1 x 13mm <strong>BGC</strong> Soundboard TM -/-/- T007 56<br />
1 x 10mm <strong>BGC</strong> Soundboard TM 1 x 10mm <strong>BGC</strong> WR Plasterboard -/-/- T008 57<br />
2 x 10mm <strong>BGC</strong> Soundboard TM 2 x 10mm <strong>BGC</strong> Soundboard TM -/-/- T010 57<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 60/60/60 T011 57<br />
1 x 13mm <strong>BGC</strong> Plasterboard 1 x 10mm <strong>BGC</strong> Plasterboard<br />
QUICK REFERENCE GUIDE<br />
STEEL FRAME - DOUBLE STUD<br />
1 x 10mm <strong>BGC</strong> Plasterboard 1 x 10mm <strong>BGC</strong> Plasterboard -/60/60 SD016 45<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 60/60/60 SD019 46<br />
2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 90/90/90 SD021 46<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 SD023 46<br />
2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 SD024 47<br />
3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 SD025 47<br />
3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/180/180 SD026 47<br />
1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- SD027 48<br />
1 x 9mm <strong>BGC</strong> Duraliner TM 1 x 9mm <strong>BGC</strong> Duraliner TM -/-/- SD028 48<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against studs) 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />
1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 6mm <strong>BGC</strong> Duraliner TM -/60/60 SD038 48<br />
1 x 6mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 SD042 49<br />
1 x 9mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 9mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 SD043 49<br />
QUICK REFERENCE GUIDE<br />
STEEL FRAME - CINEMA WALL<br />
SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER<br />
3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 SC001 50<br />
4 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 4 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 SC002 50<br />
QUICK REFERENCE GUIDE<br />
TIMBER FRAME - SINGLE STUD<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/-/- T015 58<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 60/60/60 T019 58<br />
2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 T021 58<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 T022 59<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 T023 59<br />
3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/180/180 T026 59<br />
1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- T027 60<br />
1 x 10mm <strong>BGC</strong> Soundboard TM (against studs) 1 x 10mm <strong>BGC</strong> Soundboard TM (against studs)<br />
1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- T037 60<br />
1 x 6mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 T039 60<br />
1 x 6mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 T042 61<br />
2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board -/180/180 T044 61<br />
----- 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 T046 61<br />
----- 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/90/90 T048 62<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
01 / GENERAL INFORMATION<br />
5
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 01 / GENERAL INFORMATION<br />
6<br />
QUICK REFERENCE GUIDE<br />
TIMBER FRAME - STAGGERED STUD<br />
SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER<br />
1 x 10mm <strong>BGC</strong> Soundboard TM 1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- TS006 63<br />
2 x 10mm <strong>BGC</strong> Soundboard TM 2 x 10mm <strong>BGC</strong> Soundboard TM -/-/- TS010 63<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 TS011 63<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/90/90 TS019 64<br />
2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 TS021 64<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 TS023 64<br />
1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- TS027 65<br />
1 x 9mm <strong>BGC</strong> Duraliner TM 1 x 9mm <strong>BGC</strong> Duraliner TM -/-/- TS028 65<br />
1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 10mm <strong>BGC</strong> Plasterboard -/-/- TS030 65<br />
1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- TS031 66<br />
1 x 6mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 TS039 66<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs) 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />
1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 6mm <strong>BGC</strong> Duraliner TM 60/60/60 TS040 66<br />
1 x 6mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 TS042 67<br />
QUICK REFERENCE GUIDE<br />
TIMBER FRAME - DOUBLE STUD<br />
SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 TD011 68<br />
1 x 13mm <strong>BGC</strong> Plasterboard (against studs)1 x 13mm <strong>BGC</strong> Plasterboard (against studs)<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 TD013 68<br />
1 x 10mm <strong>BGC</strong> Plasterboard (against studs)1 x 10mm <strong>BGC</strong> Plasterboard (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 TD017 68<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/60/60 60/60/60 TD019 69<br />
2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 TD021 69<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 TD023 69<br />
3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/120/120 TD026 70<br />
1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 6mm <strong>BGC</strong> Duraliner TM -/-/- TD027 70<br />
1 x 9mm <strong>BGC</strong> Duraliner TM 1 x 9mm <strong>BGC</strong> Duraliner TM -/-/- TD028 70<br />
1 x 6mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 TD039 71<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs) 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />
1 x 6mm <strong>BGC</strong> Duraliner TM 1 x 6mm <strong>BGC</strong> Duraliner TM 60/60/60 TD040 71<br />
1 x 6mm <strong>BGC</strong> Duraliner TM (against studs) 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 TD042 71
QUICK REFERENCE GUIDE<br />
EXTERIOR WALL - TIMBER STUD<br />
SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER<br />
1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 60/60/60 TE001 75<br />
1 x 7.5mm Duratex TM<br />
2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 90/90/90 TE002 75<br />
1 x 7.5mm Duratex TM<br />
1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 60/60/60 TE003 75<br />
1 x 9mm Duragrid TM<br />
2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 90/90/90 TE004 76<br />
1 x 9mm Duragrid TM<br />
1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 60/60/60 TE005 76<br />
1 x 9mm Duracom TM<br />
2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 90/90/90 TE006 76<br />
1 x 9mm Duracom TM<br />
1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 60/60/60 TE007 77<br />
1 x 14mm Nuline TM Plus<br />
2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 90/90/90 TE008 77<br />
1 x 14mm Nuline TM Plus<br />
1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 60/60/60 TE009 77<br />
1 x 9mm Durascape TM<br />
2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 90/90/90 TE010 78<br />
1 x 9mm Durascape TM<br />
1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 60/60/60 TE011 78<br />
1 x 9mm Duragroove TM<br />
2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 10mm <strong>BGC</strong> Plasterboard 90/90/90 TE012 78<br />
QUICK REFERENCE GUIDE<br />
EXTERIOR WALL - STEEL STUD<br />
SIDE 1 SIDE 2 FRL SYSTEM NUMBER PAGE NUMBER<br />
1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 SE001 79<br />
1 x 7.5mm Duratex TM<br />
2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 SE002 79<br />
1 x 7.5mm Duratex TM<br />
1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 SE003 79<br />
1 x 9mm Duragrid TM<br />
2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 SE004 80<br />
1 x 9mm Duragrid TM<br />
1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 SE005 80<br />
1 x 9mm Duracom TM<br />
2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 SE006 80<br />
1 x 9mm Duracom TM<br />
1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 SE007 81<br />
1 x 14mm Nuline TM Plus<br />
2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 SE008 81<br />
1 x 14mm Nuline TM Plus<br />
1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 SE009 81<br />
1 x 9mm Durascape TM<br />
2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 SE010 82<br />
1 x 9mm Durascape TM<br />
1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 SE011 82<br />
1 x 9mm Duragroove TM<br />
2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 SE012 82<br />
1 x 9mm Duragroove TM<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
01 / GENERAL INFORMATION<br />
7
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 01 / GENERAL INFORMATION<br />
8<br />
QUICK REFERENCE GUIDE<br />
FLOOR / CEILING - TIMBER OR STEEL JOISTS<br />
CEILING LINING FRL SYSTEM NUMBER PAGE NUMBER<br />
1 x 13mm <strong>BGC</strong> Plasterboard -/-/- C001 85<br />
2 x 13mm <strong>BGC</strong> Plasterboard -/-/- C002 85<br />
1 x 10mm <strong>BGC</strong> Ceilingboard -/-/- C003 85<br />
2 x 10mm <strong>BGC</strong> Soundboard TM -/-/- C004 86<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C005 86<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board -/-/- C0018 86<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C006 87<br />
3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 C007 87<br />
QUICK REFERENCE GUIDE<br />
FLOOR / CEILING - TIMBER OR STEEL JOISTS WITH FURRING CHANNELS<br />
CEILING LINING FRL SYSTEM NUMBER PAGE NUMBER<br />
1 x 10mm <strong>BGC</strong> Ceilingboard -/-/- C010 88<br />
1 x 13mm <strong>BGC</strong> Plasterboard -/-/- C011 88<br />
1 x 6mm <strong>BGC</strong> Duraliner TM (furring channel at 450mm max centres) -/-/- C012 88<br />
1 x 9mm <strong>BGC</strong> Duraliner TM -/-/- C013 89<br />
2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 C014 89<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C015 89<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C016 90<br />
3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 C017 90<br />
QUICK REFERENCE GUIDE FLOOR / CEILING - TIMBER OR STEEL<br />
JOISTS WITH FURRING CHANNELS & ACOUSTIC RESILIENT MOUNTS<br />
CEILING LINING FRL SYSTEM NUMBER PAGE NUMBER<br />
1 x 13mm <strong>BGC</strong> Plasterboard -/-/- C020 91<br />
1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- C021 91<br />
2 x 10mm <strong>BGC</strong> Soundboard TM -/-/- C022 91<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C023 92<br />
2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 C024 92<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C025 92<br />
QUICK REFERENCE GUIDE<br />
ROOF/CEILING - TIMBER TRUSSES<br />
CEILING LINING FRL SYSTEM NUMBER PAGE NUMBER<br />
1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- C030 93<br />
2 x 10mm <strong>BGC</strong> Soundboard TM -/-/- C031 93<br />
1 x 13mm <strong>BGC</strong> Plasterboard TM -/-/- C032 93<br />
1 x 13mm <strong>BGC</strong> Soundboard TM -/-/- C033 94<br />
2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 60/60/60 C037 94<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C034 94<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C035 95<br />
3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 C036 95
QUICK REFERENCE GUIDE<br />
ROOF/CEILING - TIMBER TRUSSES WITH FURRING CHANNELS<br />
CEILING LINING FRL SYSTEM NUMBER PAGE NUMBER<br />
1 x 10mm <strong>BGC</strong> Plasterboard -/-/- C040 96<br />
1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- C041 96<br />
1 x 13mm <strong>BGC</strong> Soundboard TM -/-/- C042 96<br />
1 x 6mm <strong>BGC</strong> Duraliner TM (furring channels at 450mm max centres) -/-/- C043 97<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C044 97<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C045 97<br />
3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 C046 98<br />
QUICK REFERENCE GUIDE ROOF/CEILING -<br />
TIMBER TRUSSES WITH FURRING CHANNELS & RESILIENT MOUNTS<br />
CEILING LINING FRL SYSTEM NUMBER PAGE NUMBER<br />
1 x 10mm <strong>BGC</strong> Soundboard TM -/-/- C050 99<br />
2 x 10mm <strong>BGC</strong> Soundboard TM -/-/- C051 99<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C052 99<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/90/90 C053 100<br />
3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/120/120 C054 100<br />
QUICK REFERENCE GUIDE<br />
COLUMNS & BEAMS<br />
LINING FRL SYSTEM NUMBER PAGE NUMBER<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 30/-/- CB01 103<br />
2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 60/-/- CB02 103<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/-/- CB03 103<br />
3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 90/-/- CB04 103<br />
3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/-/- CB05 103<br />
4 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 180/-/- CB06 103<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 30/-/- CB07 104<br />
3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board 60/-/- CB08 104<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 90/-/- CB09 104<br />
3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 120/-/- CB10 104<br />
4 x 16mm <strong>BGC</strong> <strong>Fire</strong>board 180/-/- CB11 104<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
01 / GENERAL INFORMATION<br />
9
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
STRUCTURE OF<br />
WALLS & CEILINGS<br />
STRUCTURE<br />
STEEL FRAME DESIGN<br />
AS 1170, Structural design actions – General<br />
principles defines the loads that steel framed walls are<br />
subjected to. Steel framed wall <strong>and</strong> ceiling systems<br />
must be designed according to the relevant st<strong>and</strong>ard:<br />
• AS 4100, Steel Structures<br />
• AS/NZS 4600, Cold Formed Steel Structures<br />
• AS 3623, Domestic Metal Framing<br />
• AS/NZS 2785, Suspended Ceilings.<br />
• Ensure fasteners used to fix top <strong>and</strong> bottom<br />
track are appropriate for the Uniform Distributed<br />
Loads (UDL) on walls.<br />
• At 600mm fastener centres <strong>and</strong> a UDL of<br />
0.25kPa, the fasteners must withst<strong>and</strong> a shear<br />
load of 0.75kN.<br />
• At 600mm fastener centres <strong>and</strong> a UDL of<br />
0.35kPa, the fasteners must withst<strong>and</strong> a shear<br />
load of 1.1kN.<br />
EXTERIOR WALLS AND CEILINGS<br />
Frame design of exterior wall systems must consider:<br />
INTERIOR WALLS AND CEILINGS<br />
All interior wall systems <strong>and</strong> wall height tables<br />
published in this <strong>Guide</strong> comply with the relevant<br />
section of BCA Specification C1.8.<br />
• Local environmental loading conditions<br />
(Refer to AS 1170, Structural Design Actions –<br />
General Principles)<br />
• Applied vertical load on the studs.<br />
01 / GENERAL INFORMATION 10<br />
• Height tables for non-fire rated walls have been<br />
calculated by Rondo Building Services.<br />
As a minimum, all interior wall systems published<br />
in this <strong>Guide</strong> comply with the deflection under<br />
Uniformly Distributed Load (UDL) requirements<br />
from BCA Specification C1.8. That is, the allowable<br />
deflection under a static pressure of 0.25kPa must<br />
be less than either:<br />
• Wall height ÷ 240, or<br />
• 30mm.<br />
Some applications have additional requirements<br />
such as the walls of shafts <strong>and</strong> fire isolated exits.<br />
Unusually strong wind loading conditions such as those<br />
experienced in tall buildings may require interior walls <strong>and</strong><br />
ceilings to be designed to higher pressures than<br />
the st<strong>and</strong>ard 0.25kPa. (Refer to BCA)<br />
Stud Depth<br />
70mm<br />
90mm<br />
120mm<br />
TIMBER STUD HEIGHTS<br />
Timber Grade<br />
F5<br />
F8<br />
F11<br />
F5<br />
F8<br />
F11<br />
F5<br />
F8<br />
F11<br />
CONTROL JOINTS<br />
Control joints allow for any building movement<br />
resulting from influences such as moisture migration,<br />
loading, structural movement <strong>and</strong> foundation<br />
settlement. Cracks in plasterboard <strong>and</strong> plasterboard<br />
joints can be eliminated by using control joints <strong>and</strong> the<br />
correct installation techniques. Control joints must<br />
be installed in plasterboard walls <strong>and</strong> ceilings at:<br />
• Maximum 12 metre intervals<br />
• Control joints in the structure<br />
• Any change in the substrate material.<br />
Distance between control joints may need to be<br />
reduced to less than 12 metres due to conditions<br />
such as large temperature or humidity variations.<br />
600mm 450mm<br />
Max Wall Height (m)<br />
3.1<br />
3.4<br />
3.4<br />
3.7<br />
3.4<br />
3.8<br />
3.7<br />
4.1<br />
3.6<br />
3.9<br />
3.9<br />
4.3<br />
4.0<br />
4.4<br />
4.4<br />
4.8<br />
4.4<br />
4.9<br />
4.8<br />
5.2<br />
4.6<br />
5.1<br />
4.8<br />
5.4<br />
5.4<br />
5.8<br />
5.8<br />
5.9<br />
5.9<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
Noggings in timber stud walls must be spaced at 1350mm max centres <strong>and</strong> must not protrude past the wall framing surface<br />
SCREW FIXINGS FOR SOFT WOOD TIMBER AND LIGHTWEIGHT STEEL FRAMING<br />
Framing<br />
Soft Wood Timber<br />
Lightweight Steel up to<br />
0.8mm thick<br />
Lightweight Steel from<br />
0.8mm to 1.6mm thick<br />
<strong>Fire</strong>board Thickness<br />
13mm<br />
16mm<br />
13mm<br />
16mm<br />
13mm<br />
16mm<br />
Stud Thickness<br />
35mm<br />
45mm<br />
35mm<br />
45mm<br />
35mm<br />
45mm<br />
35mm<br />
45mm<br />
35mm<br />
45mm<br />
35mm<br />
45mm<br />
35mm<br />
45mm<br />
35mm<br />
45mm<br />
35mm<br />
45mm<br />
Screw Type<br />
No.6 Type ‘W’<br />
No.6 Type ‘W’<br />
No.6 Type ‘S’ Needle Point<br />
No.6 Type ‘S’ Needle Point<br />
No.6 Type ‘D’ Drill Point<br />
No.6 Type ‘D’ Drill Point<br />
1st Layer<br />
32mm<br />
45mm<br />
25mm<br />
30mm<br />
32mm<br />
32mm<br />
Stud spacing<br />
Screw Length<br />
2nd Layer<br />
50mm<br />
65mm<br />
45mm<br />
45mm<br />
45mm<br />
45mm<br />
3rd Layer<br />
65mm<br />
75mm<br />
50mm<br />
65mm<br />
65mm<br />
65mm
Table 1: 0.25kPa - NON LOAD BEARING WALLS<br />
WALL FRAME<br />
AND LINING<br />
CONFIGURATION<br />
600mm CENTRES<br />
LINED BOTH SIDES<br />
600mm CENTRES<br />
ONE SIDE<br />
STAGGERED STUDS<br />
BOXED<br />
STAGGERED STUDS<br />
Table 2: 0.35kPa - NON LOAD BEARING WALLS<br />
WALL FRAME<br />
AND LINING<br />
CONFIGURATION<br />
600mm CENTRES<br />
LINED BOTH SIDES<br />
600mm CENTRES<br />
ONE SIDE<br />
STAGGERED STUDS<br />
BOXED<br />
STAGGERED STUDS<br />
Table 3: NOGGING REQUIREMENTS<br />
LINING<br />
CONFIGURATION<br />
LINED<br />
BOTH SIDES<br />
LINED<br />
ONE SIDE<br />
STAGGERED STUDS<br />
STUD SIZE<br />
BMT<br />
LININGS (mm)<br />
10<br />
13<br />
16<br />
(-/180/180)<br />
10<br />
13<br />
16<br />
10<br />
10<br />
STUD SIZE<br />
BMT<br />
LININGS (mm)<br />
10<br />
13<br />
16<br />
(-/180/180)<br />
10<br />
13<br />
16<br />
10<br />
10<br />
WALL<br />
HEIGHT<br />
0 - 4400<br />
4400 - 8800<br />
0 - 3000<br />
3000 - 6000<br />
6000 - 8000<br />
All<br />
51<br />
0.5 0.75<br />
2770 2910<br />
3200 3320<br />
3380 3520<br />
2310 2620<br />
2310 2620<br />
2310 2620<br />
51<br />
0.5 0.75<br />
2420 2550<br />
2810 2920<br />
3000 3120<br />
2070 2340<br />
2070 2340<br />
2070 2340<br />
NO. OF<br />
NOGGINGS<br />
0<br />
1<br />
1<br />
2<br />
3<br />
0<br />
STEEL STUD HEIGHTS -<br />
NON LOAD BEARING WALLS<br />
64<br />
76<br />
92<br />
0.5 0.75 1.15 0.55 0.75 1.15 0.55 0.75 1.15<br />
MAXIMUM WALL HEIGHT (mm)<br />
3330 3920 4160 3710 4420 4650 4550 4830 5110<br />
3720 4210 4420 4140 5010 5220 4950 5500 5750<br />
3910 4340 4510 4300 5250 5420 5190 5710 5930<br />
2720 3130 3520<br />
2720 3240 3570<br />
2750 3270 3590<br />
2230 2740 3300<br />
2710 3360 4160<br />
64<br />
76<br />
92<br />
0.5 0.75 1.15 0.55 0.75 1.15 0.55 0.75 1.15<br />
MAXIMUM WALL HEIGHT (mm)<br />
2930 3480 3700 3260 *3880 *4090 *4030 *4220 *4480<br />
3290 3740 3930 3650 4420 4600 4400 4840 5060<br />
3450 3830 3990 3790 4610 4770 4610 5010 5200<br />
2430 2800 3150<br />
2430 2880 3170<br />
2430 2900 3180<br />
2020 2470 2960<br />
2490 3040 3710<br />
3230 3590 4060<br />
3260 3830 4060<br />
3260 3880 4060<br />
Notes to Tables: Information provided by Rondo Building Services<br />
<strong>and</strong> as such the performances detailed are limited to the Rondo range of products<br />
Deflection limited to the lesser of H/240 or 30mm, in accordance with the BCA Specification C1.8<br />
All walls are non load bearing, except for self weight<br />
Table 1 loadings: Pultimate = 0.375kPa, Pservice = 0.25kPa<br />
Table 2 loadings: Pultimate = 0.525kPa, Pservice = 0.35kPa<br />
All loadings in accordance with AS1170:2002<br />
Walls analysed in accordance with AS/NZS4600<br />
Noggings are to be installed as per Table 3<br />
Staggered stud walls have been checked based on zero noggings, <strong>and</strong> assumed 92mm tracks<br />
Tables have been prepared by Rondo Building Services Pty Ltd<br />
The design pressures are not suitable for external wall applications<br />
The wall heights assume the stud <strong>and</strong> track sections are of the same, or similar, gauge<br />
Wall heights do not consider connection capacity, which should be checked as per Table 4<br />
*Green highlights indicate wall height may be limited by plasterboard linings<br />
3740 4160 4710<br />
3740 4210 4710<br />
3740 4220 4710<br />
150<br />
0.75 1.15<br />
*6600 *7230<br />
7030 7530<br />
7220 7650<br />
5300 *6800<br />
5300 6800<br />
5290 6800<br />
150<br />
0.75 1.15<br />
Table 4: WALL HEIGHT LIMITS BASED ON WALL LININGS<br />
LINING<br />
CONFIGURATION<br />
LINED<br />
BOTH SIDES<br />
LINED<br />
ONE SIDE<br />
STAGGERED STUDS<br />
2890 3210 3630<br />
2890 3380 3630<br />
2890 3420 3630<br />
WALL<br />
HEIGHT<br />
1 x 10mm<br />
1 x 13mm<br />
1 x 16mm<br />
0.50/0.55BMT<br />
1 x 10mm<br />
1 x 13mm<br />
1 x 16mm<br />
1 x 10mm<br />
3340 3720 *4210<br />
3340 3720 4210<br />
3340 3720 4210<br />
MAX WALL HEIGHTS<br />
0.25kPa 0.35kPa<br />
5330<br />
8000<br />
12000<br />
5330<br />
5330<br />
8000<br />
10000<br />
5330<br />
*5840 *6420<br />
*6250 *6780<br />
6410 6910<br />
*4790 *6210<br />
4790 *6210<br />
4780 6210<br />
3800<br />
5710<br />
8570<br />
3800<br />
3800<br />
5710<br />
7140<br />
3800<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
01 / GENERAL INFORMATION<br />
11
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 01 / GENERAL INFORMATION<br />
12<br />
ENVIRONMENTAL<br />
INFORMATION<br />
<strong>BGC</strong> Plasterboard shares the general community<br />
concern for the environment <strong>and</strong> seeks to reduce its<br />
environmental footprint in all aspects of its<br />
operations.<br />
Natural gypsum, the principal ingredient of<br />
<strong>BGC</strong>’s plasterboard products is mined locally at<br />
Cape Cuvier, Western Australia, which is renowned<br />
for having some of the highest purity gypsum in<br />
the world.<br />
<strong>BGC</strong> Plasterboard has set prudent environmental<br />
targets for waste minimisation <strong>and</strong> energy <strong>and</strong><br />
water use, <strong>and</strong> is an active participant in<br />
environmental reporting through the Energy<br />
Efficiency, Waterwise <strong>and</strong> Emissions reporting<br />
programs.<br />
Through strict quality control systems, production<br />
waste is minimised <strong>and</strong> wastage is recycled<br />
back into new plasterboard.<br />
GOOD ENVIRONMENTAL CHOICE AUSTRALIA<br />
Good Environmental Choice Australia is an environmental<br />
labelling program which aims to provide consumers with<br />
the knowledge that the product they are purchasing has<br />
met certain environmental performance st<strong>and</strong>ards which<br />
have been developed <strong>and</strong> assessed in line with<br />
International labelling st<strong>and</strong>ards.<br />
PRODUCT<br />
PLASTERBOARD<br />
CEILINGBOARD<br />
WATER RESISTANT BOARD<br />
SOUNDBOARD TM<br />
FIREBOARD<br />
WATER RESISTANT<br />
FIREBOARD<br />
IMPACTBOARD<br />
CURVEBOARD TM<br />
APPLICATION<br />
Scientifically recognised benchmarks for environmental<br />
performance have been developed against which<br />
products <strong>and</strong> services are assessed <strong>and</strong> evaluated to<br />
determine whether the product or service should be<br />
awarded the Good Environmental Choice Label.<br />
All <strong>BGC</strong> Plasterboard products have been certified<br />
by GECA which means that the products <strong>and</strong> their<br />
manufacturing environment have been evaluated<br />
<strong>and</strong> deemed to comply with the strict guidelines<br />
set by GECA.<br />
GECA certification is recognised by the Green Building<br />
Council of Australia <strong>and</strong> may assist in achieving up to<br />
3 Green Star points.<br />
<strong>BGC</strong>-2011<br />
GECA 04-2011v2-<br />
PANEL BOARDS<br />
• Interior Wall lining system<br />
• Suitable for residential & commercial applications<br />
• Cost Effective<br />
• Ready for decoration<br />
• Quick <strong>and</strong> simple to install<br />
• Excellent acoustic performance<br />
• Interior ceiling lining system<br />
• Suitable for residential <strong>and</strong> commercial applications<br />
• Cost effective<br />
• Quick <strong>and</strong> simple to install<br />
• Specifically designed for wet areas<br />
• Has a low absorption core<br />
• Light blue face for ease of identification<br />
• Quick <strong>and</strong> simple to install<br />
• Eliminates or greatly reduces unwanted noise travelling between rooms<br />
• Has a higher density core than st<strong>and</strong>ard plasterboard<br />
• Is ideal for upgrading the acoustic performance of existing walls or ceilings<br />
• Is lightweight <strong>and</strong> easy to install<br />
• Installation <strong>and</strong> h<strong>and</strong>ling is similar to that of st<strong>and</strong>ard board<br />
• Higher resistance to fire than st<strong>and</strong>ard plasterboard<br />
• Suitable for interior walls <strong>and</strong> ceilings<br />
• Suitable for fire isolated exits <strong>and</strong> public corridors<br />
• Quick <strong>and</strong> simple to install<br />
• Has a light pink face for ease of identification<br />
• Designed for wet areas where FRL is required<br />
• Ideal in partitioning situations<br />
• Can be used in ceilings if required<br />
• Quick <strong>and</strong> simple to install<br />
• Specifically designed for high impact areas<br />
• Suitable for residential & commercial applications<br />
• High resistance to soft body impact<br />
• Reduced indentations from hard body impact<br />
• Equivalent acoustic performance to <strong>BGC</strong> Soundboard<br />
• Stronger than st<strong>and</strong>ard 13mm plasterboard<br />
• Same installation as st<strong>and</strong>ard plasterboard<br />
• Easy to join <strong>and</strong> finish<br />
• Easy to repair<br />
• Provides design flexibility <strong>and</strong> freedom<br />
• Enables construction of contoured walls or ceilings<br />
• Allows bending to small radii<br />
• Has recessed edges on long edges to provide a continuous surface once flushed<br />
• Saves time <strong>and</strong> money on installation requiring curved surfaces<br />
• Lightweight <strong>and</strong> easy to install<br />
• Can be easily applied to timber or light-steel framing<br />
• Can be easily finished in a number of finishes
BOUNDARY/EXTERIOR WALLS<br />
Certain <strong>BGC</strong> Fibre Cement products when used in<br />
conjunction with 16mm Wet Area <strong>Fire</strong>board can achieve<br />
both 60/60/60 <strong>and</strong> 90/90/90 FRL (<strong>Fire</strong> Resistance Level)<br />
fire ratings from the outside as required by the BCA.<br />
Where an exterior wall is required to achieve 60/60/60<br />
FRL from the outside, 1 layer of 16mm Wet Area<br />
<strong>Fire</strong>board installed with certain <strong>BGC</strong> Fibre Cement<br />
products over the Wet Area <strong>Fire</strong>board will meet minimum<br />
BCA requirements.<br />
Similarly 2 layers of 16mm Wet Area <strong>Fire</strong>board used<br />
in conjunction with certain <strong>BGC</strong> Fibre Cement products<br />
will achieve 90/90/90 from the outside.<br />
There are 6 <strong>BGC</strong> Fibre Cement products that can be<br />
used in conjunction with 16mm Wet Area <strong>Fire</strong>board to<br />
achieve the fire ratings required for boundary/exterior<br />
walls. These are:<br />
• 7.5mm Duratex TM<br />
• 9.0mm Duragrid TM<br />
• 9.0mm Duracom TM<br />
• 9.0mm Durascape TM<br />
• 9.0mm Duragroove TM<br />
• 14.0mm Nuline TM Plus<br />
NOTE: All exterior walls must have sarking beneath<br />
the <strong>BGC</strong> Fibre Cement products. No adhesives are to<br />
be used when installing Wet Area <strong>Fire</strong>board <strong>and</strong> the<br />
<strong>BGC</strong> Fibre Cement products. Nails or screws must<br />
be used.<br />
EXTERIOR WALLS/<br />
BUSHFIRE INFORMATION<br />
BUSHFIRE INFORMATION<br />
AS3959:2009 sets out a series of Bushfire threat levels<br />
to buildings described as BAL (Bushfire Attack Levels)<br />
as follows:<br />
BAL-Low, BAL-12.5, BAL-19, BAL-29, BAL-40 or<br />
BAL-FZ (Flamezone).<br />
<strong>BGC</strong> Fibre Cement <strong>and</strong> <strong>BGC</strong> Plasterboard products<br />
are eminently suited for both bushfire <strong>and</strong> boundary wall<br />
applications in residential <strong>and</strong> multi residential buildings<br />
when used correctly.<br />
The chart on the next pages shows the different<br />
BAL levels that different <strong>BGC</strong> Fibre Cement <strong>and</strong> <strong>BGC</strong><br />
Plasterboard products can achieve if installed correctly.<br />
For detailed <strong>Fire</strong> <strong>and</strong> <strong>Acoustic</strong> results as well as fixing<br />
sketches for different products, please see the Exterior<br />
Wall pages in the <strong>Fire</strong> <strong>and</strong> <strong>Acoustic</strong> Data section of this<br />
guide on pages 75-82.<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
01 / GENERAL INFORMATION<br />
13
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 01 / GENERAL INFORMATION<br />
14<br />
BUSHFIRE<br />
MATRIX<br />
APPLICATIONS<br />
MATERIALS<br />
TO ENCLOSE<br />
SUBFLOOR<br />
SPACES TO<br />
BUILDINGS<br />
EXTERIOR WALLS<br />
(PARTS LESS THAN<br />
400MM FROM<br />
GROUND OR NEAR<br />
HORIZONTAL<br />
SURFACE<br />
(110MM IN<br />
WIDTH FROM WALL<br />
EXTERIOR WALLS<br />
(OTHER)<br />
EAVES LINING<br />
FASCIAS AND<br />
BARGEBOARDS<br />
BAL 12.5<br />
Durasheet TM 4.5mm<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durasheet TM 4.5mm<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durasheet TM 4.5mm<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durasheet TM 4.5mm<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
BAL 19<br />
Durasheet TM 4.5mm<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durasheet TM 4.5mm<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durasheet TM 4.5mm<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durasheet TM 4.5mm<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
BAL 29<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Nuline TM Plus 14.0mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Nuline TM Plus 14.0mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Durasheet TM 4.5mm<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
BAL 40<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Nuline TM Plus 14.0mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
BAL FZ>10m<br />
<strong>BGC</strong> system - T051<br />
Exposed side<br />
7.5mm Duratex TM or 9mm<br />
Duragrid TM or 9mm/12mm<br />
Duracom TM or 9mm<br />
Durascape TM or 9mm<br />
Duragroove TM or<br />
14mm Nuline TM Plus<br />
16mm Wet Area <strong>Fire</strong>board<br />
Unexposed Side<br />
10mm Plasterboard<br />
<strong>BGC</strong> system - T051<br />
Exposed side<br />
7.5mm Duratex TM or 9mm<br />
Duragrid TM or 9mm/12mm<br />
Duracom TM or 9mm<br />
Durascape TM or 9mm<br />
Duragroove TM or<br />
14mm Nuline TM Plus<br />
16mm Wet Area <strong>Fire</strong>board<br />
Unexposed Side<br />
10mm Plasterboard<br />
BAL FZ
APPLICATIONS<br />
GABLES (PARTS<br />
LESS THAT 400MM<br />
FROM GROUND OR<br />
NEAR HORIZONTAL<br />
SURFACE (110MM IN WIDTH<br />
FROM WALL<br />
GABLES (OTHER)<br />
MATERIALS<br />
TO ENCLOSE<br />
SUBFLOOR SPACES<br />
OF VERANDAS,<br />
DECKS STEPS,<br />
RAMPS AND<br />
LANDINGS<br />
BAL 12.5<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durasheet TM 4.5mm<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durasheet TM 4.5mm<br />
(over 400mm)<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
BAL 19<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durasheet TM 4.5mm<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durasheet TM 4.5mm<br />
(over 400mm)<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
BAL 29<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Nuline TM Plus 14.0mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Durasheet TM 4.5mm<br />
Durasheet TM 6.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 7.5mm<br />
Duratex TM 9.0mm<br />
Duraplank TM 7.5mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
BAL 40<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
Duracom TM 9.0mm<br />
Duracom TM 12.0mm<br />
Duratex TM 9.0mm<br />
Nuline TM Plus 14.0mm<br />
Durascape TM 9.0mm<br />
Duragroove TM 9.0mm<br />
BAL FZ>10m<br />
BUSHFIRE<br />
MATRIX<br />
BAL FZ
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 01 / GENERAL INFORMATION<br />
16
SOUND INSULATION<br />
Every partition has a sound insulation rating.<br />
A very basic partition may have a sound insulation<br />
rating of approximately R w 30. A cinema partition on<br />
the other h<strong>and</strong> may have a rating of around R w 70.<br />
BASIC WALL<br />
S001<br />
The R w value is the sound insulation rating, for<br />
airborne sound. STC is another sound insulation<br />
rating. However STC is no longer in common<br />
use in Australia.<br />
A higher R w rating means a better partition for<br />
sound insulation. Airborne sound insulation ratings<br />
can range from as low as R w 10 -15 up to values<br />
of R w 75 <strong>and</strong> greater. Examples of R w ratings for<br />
different types of partitions are shown below.<br />
CONSTRUCTION<br />
S001<br />
S010<br />
SS010<br />
SD023<br />
SD025<br />
R w 30 R w 70<br />
Typical<br />
R w<br />
30<br />
40<br />
55<br />
65<br />
70<br />
CINEMA WALL<br />
SC001<br />
EG: PARTITIONS<br />
SEPARATING:<br />
RETAIL<br />
TENANCIES<br />
PRIVATE<br />
OFFICES<br />
BOARD<br />
ROOMS<br />
APARTMENTS<br />
CINEMAS<br />
Sometimes the R w value includes a C tr rating,<br />
R w + C tr . C tr is a sound insulation rating for<br />
low-frequency noise, like trucks <strong>and</strong> stereo<br />
subwoofers.<br />
For example, the R w 40 partition below<br />
has a C tr rating of -10.<br />
S002<br />
R w 40<br />
C tr -10<br />
R w + C tr 30<br />
ACOUSTICS<br />
Here, the combined sound insulation rating<br />
is R w + C tr 30.<br />
C tr is a negative number <strong>and</strong> values typically<br />
range from about -4 to about -12. The C tr<br />
rating depends on the mass of the partition.<br />
A heavier partition will have a smaller C tr rating.<br />
Choosing the right partition for the job means<br />
choosing a partition with the right sound insulation<br />
rating. If acoustics is important for your project,<br />
we recommend that you contact a qualified<br />
acoustic consultant for advice.<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
17<br />
02 / ACOUSTIC INFORMATION
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 18<br />
02 / ACOUSTIC INFORMATION<br />
ACOUSTICS<br />
BUILDING CODE OF AUSTRALIA:<br />
WHO, WHAT, WHY AND HOW?<br />
Who?<br />
The Building Code of Australia (BCA) sets acoustic<br />
ratings for residential buildings.<br />
What?<br />
The BCA sets acoustic ratings for a range of buildings<br />
including apartments, hotels, student accommodation<br />
<strong>and</strong> aged-care buildings. The acoustic ratings are for<br />
inter-tenancy walls <strong>and</strong> floors in these buildings.<br />
For example, a wall between two apartments should<br />
have an airborne sound insulation rating of R w +C tr 50.<br />
<strong>Acoustic</strong> ratings also apply to entry doors <strong>and</strong> to<br />
services such as ducting <strong>and</strong> water, soil <strong>and</strong> waste<br />
pipes in the inter-tenancy walls, floors <strong>and</strong> riser shafts.<br />
Why?<br />
The BCA ratings are a minimum acoustic st<strong>and</strong>ard for<br />
residential buildings. This means that someone living<br />
in an apartment can expect a reasonable amount of<br />
acoustic privacy from their neighbours.<br />
The BCA ratings are a minimum st<strong>and</strong>ard. Apartments<br />
<strong>and</strong> buildings built to a higher quality level generally<br />
require walls <strong>and</strong> floors which exceed BCA st<strong>and</strong>ards.<br />
How?<br />
Different sound insulation ratings apply to different<br />
building elements, depending on the rooms being<br />
separated. In some cases ratings include the C tr .<br />
Some cases also include a requirement for the partition<br />
to be discontinuous (see below for further discussion).<br />
The specific acoustic requirements from the BCA are<br />
detailed in the table below.<br />
BCA INTER-TENANCY AIRBORNE SOUND INSULATION REQUIREMENTS<br />
Inter-tenancy partition<br />
Wall separating habitable rooms<br />
such as living areas <strong>and</strong> bedrooms<br />
Wall separating wet areas<br />
such as bathrooms <strong>and</strong> laundries<br />
Wall separating a wet area or<br />
kitchen from a habitable room<br />
Wall separating a sole-occupancy<br />
unit from a stairway, public corridor,<br />
public lobby, etc<br />
Wall separating a sole-occupancy<br />
unit from a plant room or lift shaft<br />
Floor separating<br />
sole-occupancy units<br />
Floor separating a sole-occupancy<br />
unit from a plant room, lift shaft,<br />
stairway, public corridor, public<br />
lobby or the like<br />
Door separating a sole-occupancy<br />
unit from a public corridor, public<br />
lobby, etc<br />
Wall, floor or riser separating a duct,<br />
soil, waste or water supply pipe from<br />
a habitable room<br />
Wall floor or riser separating a duct,<br />
soil, waste or water supply pipe from<br />
a wet area or kitchen<br />
Sound insulation<br />
R w + C tr ≥ 50<br />
R w + C tr ≥ 50<br />
R w + C tr ≥ 50<br />
R w ≥ 50<br />
R w ≥ 50<br />
R w + C tr ≥ 50<br />
R w + C tr ≥ 50<br />
R w ≥ 30<br />
R w + C tr ≥ 40<br />
R w + C tr ≥ 25<br />
Notes<br />
Note: BCA Requirements in Queensl<strong>and</strong> <strong>and</strong> Northern Territory differ from those stated in the table above.<br />
<strong>BGC</strong> recommends further investigation as to BCA requirements in Queensl<strong>and</strong> <strong>and</strong> Northern Territory.<br />
Wall impact isolation not required<br />
Wall impact isolation not required<br />
Discontinuous construction required<br />
Wall impact isolation not required<br />
Discontinuous construction required<br />
Floor impact isolation criteria<br />
also apply<br />
Floor impact isolation treatment<br />
also required
The figure below shows an example of the type of acoustic performance required to inter-tenancy<br />
partitions separating two apartments.<br />
R w + C tr ≥ 50 discontinuous<br />
R w + C tr ≥ 50<br />
R w ≥ 50<br />
KITCHEN<br />
BEDROOM<br />
LIVING<br />
BATHROOM<br />
CORRIDOR<br />
BATHROOM<br />
BEDROOM<br />
BEDROOM<br />
Example of BCA performance requirements for different sections of inter-tenancy partitions<br />
The acoustic performance of the wall depends on<br />
the type of room on each side of the partition.<br />
For example, where the wall separates a bedroom or<br />
living area in one apartment from a wet area such as<br />
APARTMENT INTER-TENANCY WALL<br />
Where acoustic amenity is required to exceed<br />
the BCA minimum performance requirement,<br />
<strong>BGC</strong> recommend wall system SD021 for inter-tenancy<br />
walls between apartments.<br />
SD021<br />
ACOUSTICS<br />
KITCHEN<br />
LIVING<br />
a kitchen or bathroom in another apartment, the<br />
partition should be of discontinuous construction.<br />
The acoustic performance of a partition between<br />
an apartment <strong>and</strong> a common corridor does not<br />
include the Ctr.<br />
<strong>BGC</strong> RECOMMENDED<br />
WALL TYPE<br />
The system has been laboratory tested to<br />
R w 65 <strong>and</strong> R w + C tr 58.<br />
This wall system is classified as a discontinuous<br />
construction <strong>and</strong> exceeds the inter-tenancy partition<br />
requirements of the BCA. It will provide a good level<br />
of acoustic separation around an apartment <strong>and</strong> is<br />
recommended for all apartment types up to<br />
medium-to-high quality.<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
02 / ACOUSTIC INFORMATION<br />
19
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 02 / ACOUSTIC INFORMATION<br />
20<br />
ACOUSTIC<br />
CONCEPTS<br />
INSULATION IN WALL, FLOOR AND ROOF<br />
CONSTRUCTIONS<br />
<strong>Acoustic</strong> ratings in this <strong>Guide</strong> are provided for two<br />
different types of polyester insulation: 50mm thick,<br />
9kg/m3 polyester <strong>and</strong> 75mm thick, 30kg/m3.<br />
Fibreglass insulation of the same thickness <strong>and</strong> mass<br />
may be used in lieu of these two types of polyester<br />
without changing the acoustic ratings.<br />
ON-SITE PERFORMANCE<br />
In an acoustic laboratory, sound insulation ratings<br />
are measured using purpose built rooms which give<br />
very accurate, reproducible results. The Rw value<br />
is a laboratory result.<br />
Things are not so simple on site. For example,<br />
the rating of a wall can be affected by the floor it<br />
is mounted on, the overhead ceiling, the side walls<br />
<strong>and</strong> any penetrations <strong>and</strong> services which run through<br />
the wall or floor above. The DnT,w value is an on<br />
site result.<br />
The Rw <strong>and</strong> DnT,w values are similar in concept but<br />
are not the same. The difference is the DnT,w accounts<br />
for the imperfect testing conditions found on site.<br />
As a guide, the DnT,w value of a partition is typically<br />
around 5dB lower than the Rw value.<br />
The Ctr correction can be applied to both Rw<br />
<strong>and</strong> DnT,w ratings. For example, the BCA states that<br />
walls separating adjacent apartments should have a<br />
minimum DnT,w + Ctr 45 rating, when site verification<br />
is being used for assessment purposes.<br />
FLANKING<br />
Flanking transmission means sound transmission<br />
around the partition rather than through it.<br />
Flanking transmission can occur when the floor,<br />
walls or ceiling around a separating partition have<br />
poor sound insulation, which decreases the<br />
performance of the separating partition.<br />
Flanking Flanking transmission sound is common transmission<br />
site <strong>and</strong><br />
should be carefully assessed.<br />
IMPACT SOUND AND DISCONTINUITY<br />
So far, we have covered airborne sound which means<br />
sound such as voices <strong>and</strong> audio-speakers which travels<br />
through air. Impact sound means sound generated from<br />
impact on the partitions <strong>and</strong> floors of the building.<br />
For example, if someone walks on their tiled floor,<br />
a person on the floor beneath will hear the impact<br />
sound. Another example is someone closing a kitchen<br />
cupboard. If the cupboard is connected to the wall,<br />
a person on the other side of the wall will hear the<br />
impact sound from the cupboard door. For example,<br />
double stud partitions are discontinuous <strong>and</strong> single<br />
steel studs partitions are not.<br />
Impact sound<br />
In the BCA some partitions need to provide wall<br />
impact isolation. For example, a partition between<br />
a kitchen or bathroom in one apartment <strong>and</strong> a living<br />
room or bedroom in another apartment should have<br />
a discontinuous construction. This means the partition<br />
should include a structural break.<br />
There are a number of resilient acoustic mounts<br />
available in the market place. It is critical that a suitable<br />
resilient acoustic mount be selected in order for wall,<br />
floor or roof construction to achieve the acoustic<br />
rating. Good quality resilient acoustic mounts should<br />
be selected <strong>and</strong> loaded appropriately to ensure that<br />
static deflection is sufficient to achieve good acoustic<br />
performance. A suitable static deflection is typically<br />
around 5mm. Rondo <strong>and</strong> Embelton supply suitable<br />
resilient acoustic mounts.
CONTINUOUS CONSTRUCTION e.g. S001<br />
S001<br />
DISCONTINUOUS CONSTRUCTION e.g. SD019<br />
SD019<br />
QUALITY CONSTRUCTIONS / GENERAL DETAILING<br />
Quality on-site construction is critical to achieve a<br />
good level of acoustic performance in any building<br />
project. Small gaps <strong>and</strong> holes can often occur in<br />
<strong>and</strong> around a wall or floor. If these are left untreated<br />
they significantly down-rate the acoustic performance.<br />
Any gaps <strong>and</strong> holes must be minimised. Gaps <strong>and</strong><br />
holes which do occur, including those around services<br />
penetrations, should be acoustically sealed to<br />
minimise the leakage effect on acoustic performance.<br />
ACOUSTIC<br />
CONCEPTS<br />
ACOUSTIC RATINGS<br />
<strong>Acoustic</strong> ratings in this <strong>Guide</strong> have been prepared by<br />
Marshall Day <strong>Acoustic</strong>s Pty Ltd. <strong>Acoustic</strong> ratings have<br />
been developed based upon laboratory test data for<br />
<strong>BGC</strong> wall <strong>and</strong> floor systems, other available laboratory<br />
data for comparable constructions <strong>and</strong> calculations<br />
based on theoretical models. Ratings are expected<br />
to be accurate to within ± 2.5 Rw.<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
02 / ACOUSTIC INFORMATION<br />
21
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 02 / ACOUSTIC INFORMATION<br />
22<br />
GLOSSARY OF<br />
ACOUSTIC TERMS<br />
dB<br />
NOISE<br />
SOUND INSULATION or<br />
SOUND REDUCTION<br />
R w<br />
D nT,w<br />
C tr<br />
R w +C tr<br />
D nT,w +C tr<br />
FLANKING<br />
STRUCTURE-BORNE<br />
TRANSMISSION<br />
Decibel. The unit of sound level.<br />
Unwanted sound.<br />
When sound hits a surface, some of the sound energy travels<br />
through the material. ‘Sound insulation or sound reduction’ refers to<br />
ability of a material to stop sound travelling through it.<br />
Weighted sound reduction index.<br />
A single number rating of the sound insulation performance of<br />
a specific building element such as a wall or floor.<br />
R w is measured in a laboratory.<br />
Weighted st<strong>and</strong>ardised level difference.<br />
A single number rating of the sound level difference between two rooms.<br />
D nT,w is typically used to measure on-site sound insulation performance<br />
of building elements such as a walls or floors.<br />
The on-site D nT,w value is typically about 5 points less than the<br />
laboratory R w value.<br />
C tr is a sound insulation adjustment, commonly used with R w <strong>and</strong> D nT,w .<br />
C tr adjusts for low frequency noise, such as noise from trucks <strong>and</strong><br />
subwoofers. C tr values typically range from about -4 to about -12.<br />
The combined value of Weighted sound reduction index R w + Spectrum<br />
adaptation term C tr .<br />
A single number rating of the sound insulation performance of a building<br />
element with the C tr correction included. R w +C tr values are measured<br />
in the laboratory <strong>and</strong> are lower than R w values.<br />
The combined value of Weighted st<strong>and</strong>ardised level difference D nT,w<br />
+ spectrum adaptation term C tr .<br />
A single number rating of the sound level difference between two rooms<br />
with the C tr correction included. D nT,w +C tr is used to measure on-site<br />
sound insulation performance of building elements such as a walls or<br />
floors. D nT,w +C tr values are lower than D nT,w values.<br />
Transmission of sound energy through paths adjacent to the building<br />
element being considered. For example, sound may be transmitted<br />
around a wall by travelling up into the ceiling space <strong>and</strong> then down<br />
into the adjacent room.<br />
Transmission of sound energy as vibrations inside the structure<br />
of a building.
INTRODUCTION<br />
<strong>BGC</strong> fire-rated systems consist of single or multiple<br />
layers of <strong>BGC</strong> <strong>Fire</strong>board sheets, screw-fixed to steel<br />
framing <strong>and</strong> nail or screw fixed to timber stud framing.<br />
<strong>BGC</strong> <strong>Fire</strong>board is manufactured to the requirements<br />
of Australian St<strong>and</strong>ards AS/NZS 2588:1998 -<br />
“Gypsum plasterboard” <strong>and</strong> must be installed in<br />
accordance with the Australian St<strong>and</strong>ards AS/NZS<br />
2589:2007 Gypsum linings - Application <strong>and</strong> Finishing.<br />
<strong>BGC</strong> fire rated systems have been tested<br />
according to AS/NZS 3837: 1998 <strong>and</strong> AS/NZS<br />
1530.4, by NATA accredited testing laboratories.<br />
<strong>BGC</strong> <strong>Fire</strong>board has a light-pink facing liner board <strong>and</strong><br />
<strong>BGC</strong> Wet Area <strong>Fire</strong>board has a blue/grey facing liner<br />
board for easy identification <strong>and</strong> is available in 13mm<br />
<strong>and</strong> 16mm thicknesses with recessed edges, ready<br />
for taping <strong>and</strong> jointing with proprietary<br />
jointing materials.<br />
EARLY FIRE HAZARD INDICES<br />
<strong>BGC</strong> <strong>Fire</strong>board complies with the Building Code of<br />
Australia (BCA) Material Group Number Classification<br />
<strong>and</strong> Deemed to Satisfy Provisions, as determined<br />
by AS/NZS 3837: 1998 tests.<br />
• Material Classification: Group 1.<br />
(BCA) Specification A2.4)<br />
• Suitability as Wall <strong>and</strong> Ceiling Lining In <strong>Fire</strong>-Isolated<br />
Exits, Public Corridors, Specified <strong>and</strong> Other Areas.<br />
(BCA Specification C1.10a Section 3(c) <strong>and</strong> Table 2:<br />
Wall <strong>and</strong> Ceiling Linings Material Groups Permitted.<br />
• CSIRO BCE Certificate No 482<br />
APPLICATION<br />
<strong>BGC</strong> <strong>Fire</strong>board systems are suitable for industrial,<br />
commercial <strong>and</strong> residential applications, both in<br />
the new construction <strong>and</strong> renovation sectors.<br />
Load bearing, non-load bearing walls <strong>and</strong> partitions<br />
can be clad with single or multiple layers of <strong>BGC</strong><br />
<strong>Fire</strong>board, with or without cavity infill insulation,<br />
to achieve the required results for fire resistance:<br />
FRL <strong>and</strong> acoustic properties: RW.<br />
<strong>BGC</strong> FIRE-RESISTANT (FR)<br />
PLASTERBOARD PARTITION SYSTEMS<br />
NON-LOAD BEARING WALLS<br />
The maximum wall heights for non-load bearing<br />
fire rated walls, in this Installation <strong>Guide</strong> are for<br />
laterally loaded walls of 0.25 kPa <strong>and</strong> 0.35 kPa,<br />
as set out in the Rondo Tables on page 11.<br />
The maximum stud height is based H/240 or<br />
30mm maximum deflection, to comply with<br />
BCA 2004 Specification 1.8 Clause 3.4.<br />
LOAD BEARING WALLS<br />
Load bearing walls in this Installation <strong>Guide</strong> must<br />
be designed <strong>and</strong> constructed in accordance with<br />
AS 1684 <strong>and</strong> AS 1720, for timber construction<br />
<strong>and</strong> AS/NZS 4600 <strong>and</strong> AS 3623 for light-weight<br />
Cold-Formed-Steel (CFS) construction.<br />
Load bearing walls must be designed <strong>and</strong> constructed<br />
to take all loads without any cladding or lining.<br />
INSTALLATION<br />
Installation is to be in accordance with AS/NZS<br />
2589:2007 Gypsum linings - Application <strong>and</strong><br />
Finishing <strong>and</strong> as set out in this manual.<br />
All fire rated plasterboard must be mechanically<br />
fastener fixed to steel or timber framing.<br />
Stud adhesive must not be used.<br />
For multiple layered systems all joints must be<br />
staggered <strong>and</strong> butt joints in the outer layer may<br />
be reinforced with laminating screws.<br />
All perimeter gaps <strong>and</strong> penetrations must be<br />
fully sealed with an AS/NZS approved fire rated<br />
mastic sealant, to attain the required FRL<br />
<strong>and</strong> RW ratings.<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
03 / FIRE INFORMATION<br />
23
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
FIRE RESISTANCE TERMS<br />
AND DEFINITIONS<br />
FIRE RESISTANCE LEVEL (FRL)<br />
The nominal grading period, in minutes, that<br />
is determined by subjecting a specimen to the<br />
st<strong>and</strong>ard time temperature curve regime as set<br />
out in AS1530.4.<br />
This is to specify—<br />
(a) Structural adequacy<br />
(b) Integrity<br />
(c) Insulation<br />
These are expressed in that order.<br />
Refer to the example below<br />
INSULATION<br />
The ability of an element of construction to maintain<br />
a temperature on the surface that is not exposed to<br />
the furnace, below the limits specified, when tested<br />
in accordance with AS1530.4.<br />
Eg: 60/60/60<br />
This means that during a fire test, the system did<br />
not fail for 60 minutes for each of the criteria.<br />
Ensure fasteners used to fix top <strong>and</strong> bottom track are<br />
appropriate for the Uniform Distributed Loads (UDL)<br />
on walls.<br />
03 / FIRE INFORMATION 24<br />
60/60/60. This indicates that it is a loadbearing<br />
system as it has a figure (60) in the first area<br />
(Structural adequacy)<br />
-/60/60. This indicates that it is a non loadbearing<br />
system as it has no figure (-) in the first area<br />
(Structural adequacy)<br />
The definitions as set out in the St<strong>and</strong>ard<br />
are below:<br />
STRUCTURAL ADEQUACY<br />
The ability of a load-bearing element of construction<br />
to support a load when tested in accordance<br />
with AS1530.4.<br />
Eg: 60/60/60<br />
INTEGRITY<br />
The ability of an element of construction to resist<br />
the passage of flames <strong>and</strong> hot gases from one<br />
space to another, when tested in accordance<br />
with AS1530.4.<br />
Eg: 60/60/60<br />
VERTICAL - TEMP CELSIUS/ HORIZONTAL - TIME MINS<br />
1400<br />
1200<br />
1000<br />
800<br />
600<br />
400<br />
200<br />
At 600mm fastener centres <strong>and</strong> a UDL of 0.25kPa,<br />
the fasteners must withst<strong>and</strong> a shear load of 0.75kN.<br />
At 600mm fastener centres <strong>and</strong> a UDL of 0.35kPa,<br />
the fasteners must withst<strong>and</strong> a shear load of 1.1kN.<br />
Below is the st<strong>and</strong>ard time vs temperature table<br />
which is represented in the STANDARD TIME<br />
VS TEMPERATURE CURVE.<br />
This shows the rise in temperature vs the<br />
associated time.<br />
As indicated, in 5 minutes the temperature in<br />
the test facility has risen to 576 degrees Celsius,<br />
in 15 minutes 738 degrees Celsius <strong>and</strong> 90 minutes<br />
over 1,000 degrees Celsius <strong>and</strong> so on.<br />
Where a wall or ceiling is required to meet the<br />
various requirements under the BCA it is the job of<br />
the <strong>Fire</strong>board <strong>and</strong> the framing to prevent the flames,<br />
smoke <strong>and</strong> temperature from getting through to<br />
the other side.<br />
For example, where there is a wall required to<br />
achieve a -/120/120 system number SO21 shows<br />
2 layers of 13mm <strong>Fire</strong>board both sides of a metal<br />
stud. Effectively overall there is 52mm of fire rated<br />
plasterboard <strong>and</strong> framing to stop a peak of over<br />
1,000 degrees of heat reaching through to the<br />
other side for a period of 2 hours.<br />
0<br />
0 100 200 300 400<br />
Time Mins 0 5 10 15 30 60 90 120 180 240 360<br />
Temp Celsius 20 576 679 738 841 945 1006 1049 1110 1153 1213
CONTROL JOINTS<br />
A joint between or within discrete elements of<br />
construction, which allows for relative movement<br />
of the elements.<br />
Control joints can allow for a degree of building<br />
movement which can result from such things<br />
as moisture, loads, structural movement <strong>and</strong><br />
foundation settlement etc. Cracks in plasterboard<br />
<strong>and</strong> plasterboard joints should be eliminated by using<br />
control joints <strong>and</strong> the correct installation techniques.<br />
Control joints must be installed in plasterboard<br />
walls <strong>and</strong> ceilings at:<br />
• Maximum 12 metre intervals<br />
• Control joints in the structure<br />
• Any change in the substrate material<br />
• Junctions of dissimilar structural products<br />
• When long runs of plasterboard meet at right<br />
angle (change of direction)<br />
Distance between control joints may need to<br />
be minimised to less than 12 metres due to on<br />
site conditions such as humidity or temperature<br />
variations or where ever excessive structural<br />
movement is likely to occur.<br />
ACCEPTABLE VARIATIONS TO<br />
FIRE RATED SYSTEMS<br />
<strong>Fire</strong> rated systems must be built according to<br />
<strong>BGC</strong> installation instructions. However, there<br />
are some variations allowed that will not degrade<br />
the performance of the system:<br />
• Increasing the width of the cavity (between stud<br />
walls in a double stud wall system)<br />
• Increasing the stud size or the metal thickness<br />
• Adding noggings to support fixtures or services<br />
• Decreasing stud spacing<br />
(increasing amount of studs)<br />
• Additional fasteners<br />
• Adding non-combustible layers to a system up<br />
to a weight of 20kg/m2 <strong>and</strong> no thicker than 25mm.<br />
This includes fibre cement board up to 9mm thick<br />
<strong>and</strong> plasterboard up to 25mm thick. For load<br />
bearing walls, the load per stud must include<br />
the extra lining.<br />
<strong>BGC</strong> FIRE-RESISTANT (FR)<br />
PLASTERBOARD PARTITION SYSTEMS<br />
MODIFICATIONS TO FIRE<br />
RATED SYSTEMS<br />
<strong>Fire</strong> rated systems may be modified by the installation<br />
of the following examples but not limited to these:<br />
• <strong>Fire</strong> rated inspection hatches<br />
• <strong>Fire</strong> rated power points<br />
• <strong>Fire</strong> rated light fittings<br />
• <strong>Fire</strong> rated doors<br />
It is the responsibility of the manufacturer of additional<br />
components in a fire system to ensure that the fire<br />
<strong>and</strong> acoustic properties of the plasterboard system<br />
are maintained. Any modification not covered in<br />
this manual must be according to the relevant<br />
manufacturer’s instructions.<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
03 / FIRE INFORMATION<br />
25
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 03 / FIRE INFORMATION<br />
26
STEEL FRAME INTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 10mm <strong>BGC</strong> Plasterboard<br />
Side 2 1 x 10mm <strong>BGC</strong> Plasterboard<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> Plasterboard<br />
Side 2 1 x 13mm <strong>BGC</strong> Plasterboard<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 13mm <strong>BGC</strong> Plasterboard<br />
Side 2 1 x 13mm <strong>BGC</strong> Plasterboard<br />
S001<br />
51 64 76 92 150<br />
Rw/Rw+Ctr<br />
30/25 31/25 31/26 32/26 33/27<br />
38/29 39/29 40/30 41/31 43/34<br />
38/29 40/30 40/30 42/31 44/34<br />
71 84 96 112 170<br />
S002<br />
51 64 76 92 150<br />
Rw/Rw+Ctr<br />
33/28 34/28 34/28 35/29 37/31<br />
41/31 42/32 43/32 44/33 46/37<br />
42/31 43/32 44/32 45/34 47/37<br />
77 90 102 118 176<br />
S003<br />
51 64 76 92 150<br />
Rw/Rw+Ctr<br />
38/32 38/32 39/32 40/33 42/34<br />
45/34 46/34 47/37 49/40 49/41<br />
45/34 46/34 48/37 49/40 49/42<br />
90 103 115 131 189<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
04 / STEEL FRAME INFORMATION<br />
27
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 13mm <strong>BGC</strong> Plasterboard<br />
Side 2 2 x 13mm <strong>BGC</strong> Plasterboard<br />
S005<br />
04 / STEEL FRAME INFORMATION 28<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
STUD DEPTH mm<br />
51 64 76 92 150<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
41/34 42/33 43/37 44/37 46/38<br />
9kg - 50mm Polyester<br />
49/38 50/41 52/43 53/45 55/48<br />
30kg - 75mm Polyester<br />
49/38 50/41 53/43 54/46 55/48<br />
WALL THICKNESS mm<br />
103 116 128 144 202<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 10mm <strong>BGC</strong> Soundboard TM<br />
Side 2 1 x 10mm <strong>BGC</strong> Soundboard TM<br />
S006<br />
STUD DEPTH mm<br />
51 64 76 92 150<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
33/28 35/29 35/29 36/29 38/31<br />
9kg - 50mm Polyester<br />
41/31 42/32 44/33 44/34 47/38<br />
30kg - 75mm Polyester<br />
41/31 43/32 44/33 45/34 48/39<br />
WALL THICKNESS mm<br />
71 84 96 112 170<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> Soundboard TM<br />
Side 2 1 x 13mm <strong>BGC</strong> Soundboard TM<br />
S007<br />
STUD DEPTH mm<br />
51 64 76 92 150<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
36/31<br />
44/33<br />
44/33<br />
77<br />
37/31<br />
45/34<br />
45/35<br />
90<br />
Rw/Rw+Ctr<br />
38/32<br />
46/37<br />
46/38<br />
102<br />
39/33<br />
46/38<br />
47/38<br />
118<br />
41/34<br />
48/42<br />
49/43<br />
176
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / 60 / 60<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 10mm <strong>BGC</strong> Soundboard TM<br />
Side 2 1 x 10mm <strong>BGC</strong> WR Plasterboard<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 10mm <strong>BGC</strong> Soundboard TM<br />
Side 2 2 x 10mm <strong>BGC</strong> Soundboard TM<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
PREVIOUSLY <strong>BGC</strong>001<br />
S009<br />
51 64 76 92 150<br />
Rw/Rw+Ctr<br />
38/32 38/32 39/32 40/33 42/34<br />
44/34 46/34 47/36 48/39 49/41<br />
45/34 47/34 47/36 49/39 49/41<br />
81 94 106 122 180<br />
S010<br />
51 64 76 92 150<br />
Rw/Rw+Ctr<br />
42/34 43/36 44/37 44/37 46/38<br />
50/40 52/41 53/43 54/46 55/48<br />
50/40 52/42 53/44 54/46 55/49<br />
91 104 116 132 190<br />
S011<br />
51 64 76 92 150<br />
Rw/Rw+Ctr<br />
34/29 35/29 36/30 37/31 39/33<br />
42/32 43/32 44/33 45/36 47/40<br />
42/32 44/33 44/34 46/37 48/41<br />
77 90 102 118 176<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
04 / STEEL FRAME INFORMATION<br />
29
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
1 x 10mm <strong>BGC</strong> Plasterboard<br />
Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
S012<br />
04 / STEEL FRAME INFORMATION 30<br />
FRL<br />
- / 60 / 60<br />
FRL<br />
- / 60 / 60<br />
FRL<br />
- / 60 / 60<br />
60 / 60 / 60<br />
STUD DEPTH mm 51 64 76 92 150<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
38/33 39/33 40/33 41/34 43/35<br />
9kg - 50mm Polyester<br />
46/34 47/36 48/39 49/39 50/42<br />
30kg - 75mm Polyester<br />
46/34 48/36 49/39 49/39 50/42<br />
WALL THICKNESS mm<br />
87 100 112 128 186<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
S018<br />
STUD DEPTH mm 51 64 76 92 150<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
39/33 40/33 40/34 41/35 43/37<br />
9kg - 50mm Polyester<br />
47/35 48/38 49/41 50/41 52/44<br />
30kg - 75mm Polyester<br />
48/35 49/39 49/41 51/42 52/45<br />
WALL THICKNESS mm<br />
90 103 115 131 189<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
PREVIOUSLY <strong>BGC</strong>003<br />
S019<br />
STUD DEPTH mm 51 64 76 92 150<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
36/31 37/31 38/32 39/33 41/34<br />
9kg - 50mm Polyester<br />
44/33 45/34 46/37 46/38 48/42<br />
30kg - 75mm Polyester<br />
44/33 45/35 46/38 47/38 49/43<br />
WALL THICKNESS mm<br />
83 96 108 124 182
FRL<br />
- / 120 / 120<br />
FRL<br />
- / 120 / 120<br />
90 / 90 / 90<br />
FRL<br />
-/120/120<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
PREVIOUSLY <strong>BGC</strong>002<br />
S021<br />
STUD DEPTH mm 51 64 76 92 150<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
PREVIOUSLY <strong>BGC</strong>004<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Rw/Rw+Ctr<br />
43/36 44/38 45/39 46/39 48/41<br />
50/42 52/43 54/46 54/47 56/49<br />
50/42 52/44 54/47 55/48 56/49<br />
103 116 128 144 202<br />
S023<br />
STUD DEPTH mm 51 64 76 92 150<br />
Rw/Rw+Ctr<br />
45/38 47/40 47/39 48/40 50/42<br />
53/43 54/46 55/47 55/48 56/49<br />
54/44 55/47 55/47 56/49 56/49<br />
115 128 140 156 214<br />
S025<br />
STUD DEPTH mm 51 64 76 92 150<br />
Rw/Rw+Ctr<br />
47/41 48/41 49/42 50/43 53/45<br />
57/49 57/50 58/51 58/52 59/54<br />
57/49 58/51 58/52 58/53 59/55<br />
129 142 154 170 228<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
04 / STEEL FRAME INFORMATION<br />
31
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
S026<br />
04 / STEEL FRAME INFORMATION 32<br />
FRL<br />
- / 180 / 180<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
STUD DEPTH mm<br />
51 64 76 92 150<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
50/43 51/44 51/44 52/45 54/46<br />
9kg - 50mm Polyester<br />
58/49 58/51 58/53 59/54 59/56<br />
30kg - 75mm Polyester<br />
58/49 58/52 59/54 59/54 59/56<br />
WALL THICKNESS mm<br />
147 160 172 188 246<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
S027<br />
STUD DEPTH mm<br />
51 64 76 92 150<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
32/26 33/26 33/26 33/27 35/28<br />
9kg - 50mm Polyester<br />
41/31 41/31 43/32 44/32 46/35<br />
30kg - 75mm Polyester<br />
41/31 42/31 43/32 44/32 46/35<br />
WALL THICKNESS mm<br />
63 76 88 104 162<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 9mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM<br />
S028<br />
STUD DEPTH mm<br />
51 64 76 92 150<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
39/32<br />
45/33<br />
46/34<br />
69<br />
40/33<br />
47/35<br />
47/35<br />
82<br />
Rw/Rw+Ctr<br />
41/33<br />
48/37<br />
49/37<br />
94<br />
41/34<br />
49/38<br />
49/38<br />
110<br />
42/34<br />
49/42<br />
49/43<br />
168
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 12mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 12mm <strong>BGC</strong> Duraliner TM<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 10mm <strong>BGC</strong> Soundboard TM<br />
Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> Plasterboard<br />
Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
S029<br />
51 64 76 92 150<br />
Rw/Rw+Ctr<br />
40/33 40/33 41/35 43/36 44/37<br />
48/36 49/40 49/40 52/44 54/47<br />
48/37 49/40 49/40 53/44 54/47<br />
75 88 100 116 174<br />
S031<br />
51 64 76 92 150<br />
Rw/Rw+Ctr<br />
34/28 35/29 35/28 36/29 38/31<br />
41/31 42/32 44/32 44/33 46/36<br />
42/31 43/32 44/32 45/33 47/37<br />
67 80 92 108 166<br />
S033<br />
51 64 76 92 150<br />
Rw/Rw+Ctr<br />
34/28 35/28 35/28 36/29 38/31<br />
41/31 42/31 43/32 44/33 46/36<br />
41/31 42/32 44/32 45/33 47/37<br />
70 83 95 111 169<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
04 / STEEL FRAME INFORMATION<br />
33
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 04 / STEEL FRAME INFORMATION<br />
34<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / 60 / 60<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> Plasterboard<br />
Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
51 64 76 92 150<br />
Rw/Rw+Ctr<br />
36/30 36/30 37/31 38/31 41/34<br />
42/32 44/33 45/34 46/36 49/40<br />
43/32 45/33 46/34 47/37 49/40<br />
73 86 98 114 172<br />
51 64 76 92 150<br />
Rw/Rw+Ctr<br />
34/28 35/28 35/28 36/29 38/31<br />
41/31 43/32 45/33 46/35 49/39<br />
42/31 44/33 45/33 46/35 49/40<br />
70 83 95 111 169<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />
1 x 9mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />
1 x 9mm <strong>BGC</strong> Duraliner TM<br />
S034<br />
S035<br />
S041<br />
51 64 76 92 150<br />
Rw/Rw+Ctr<br />
45/38 47/40 47/39 48/40 50/42<br />
53/43 54/46 55/47 55/48 56/49<br />
54/44 55/47 55/47 56/49 56/49<br />
73 86 98 114 172
FRL<br />
120 / 120 / 120<br />
FRL<br />
- / 180 / 180<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 9mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
PREVIOUSLY <strong>BGC</strong> DL001<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 16mm Wet Area <strong>Fire</strong>board<br />
Side 2 2 x 16mm Wet Area <strong>Fire</strong>board<br />
S043<br />
51 64 76 92 150<br />
Rw/Rw+Ctr<br />
45/38 47/40 47/39 48/40 50/42<br />
53/43 54/46 55/47 55/48 56/49<br />
54/44 55/47 55/47 56/49 56/49<br />
73 86 98 114 172<br />
S044<br />
51 64 76 92 150<br />
Rw/Rw+Ctr<br />
45/38 47/40 47/39 48/40 50/42<br />
53/43 54/46 55/47 55/48 56/49<br />
54/44 55/47 55/47 56/49 56/49<br />
73 86 98 114 172<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
04 / STEEL FRAME INFORMATION<br />
35
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 04 / STEEL FRAME INFORMATION<br />
36<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
FRL<br />
- / 120 / 120<br />
120 / 120 / 120<br />
FRL<br />
- / 60 / 60<br />
FRL<br />
- / 120 / 120<br />
120 / 120 / 120<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1<br />
Side 2 3 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
STUD DEPTH mm 51 64 76 92 150<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1<br />
Side 2 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
STUD DEPTH mm 51 64 76 92 150<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1<br />
Side 2 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
S045<br />
Rw/Rw+Ctr<br />
38/36 - - - -<br />
- - - - -<br />
- - - - -<br />
99 112 124 140 198<br />
S046<br />
Rw/Rw+Ctr<br />
35/32 - - - -<br />
- - - - -<br />
- - - - -<br />
83 96 108 124 182<br />
S048<br />
STUD DEPTH mm 51 64 76 92 150<br />
Rw/Rw+Ctr<br />
38/36 - - - -<br />
- - - - -<br />
- - - - -<br />
99 112 124 140 198
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
STAGGERED STUD<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 10mm <strong>BGC</strong> Plasterboard<br />
Side 2 1 x 10mm <strong>BGC</strong> Plasterboard<br />
CAVITY WIDTH mm 76 92 150<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
33/27 33/27 34/28<br />
42/32 43/33 46/36<br />
42/32 44/33 47/37<br />
96 112 170<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> Plasterboard<br />
Side 2 1 x 13mm <strong>BGC</strong> Plasterboard<br />
CAVITY WIDTH mm 76 92 150<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
36/30 37/31 39/33<br />
46/34 47/36 49/38<br />
46/34 47/36 49/38<br />
102 118 176<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 10mm <strong>BGC</strong> Soundboard TM<br />
Side 2 1 x 10mm <strong>BGC</strong> Soundboard TM<br />
CAVITY WIDTH mm 76 92 150<br />
Rw/Rw+Ctr<br />
SS001<br />
SS002<br />
SS006<br />
36/30 37/30 39/32<br />
46/35 47/36 49/38<br />
47/35 48/36 49/38<br />
96 112 170<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
04 / STEEL FRAME INFORMATION<br />
37
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
STAGGERED STUD<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> Soundboard TM<br />
Side 2 1 x 13mm <strong>BGC</strong> Soundboard TM<br />
SS007<br />
04 / STEEL FRAME INFORMATION 38<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / 60 / 60<br />
CAVITY WIDTH mm 76 92 150<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
38/32 39/33 41/34<br />
9kg - 50mm Polyester<br />
48/38 49/39 52/44<br />
30kg - 75mm Polyester<br />
49/38 50/39 53/45<br />
WALL THICKNESS mm<br />
102 118 176<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 10mm <strong>BGC</strong> Soundboard TM<br />
Side 2 2 x 10mm <strong>BGC</strong> Soundboard TM<br />
SS010<br />
CAVITY WIDTH mm 76 92 150<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
46/39 46/39 49/41<br />
9kg - 50mm Polyester<br />
54/44 56/46 58/49<br />
30kg - 75mm Polyester<br />
55/44 57/47 59/50<br />
WALL THICKNESS mm<br />
116 132 190<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
SS011<br />
CAVITY WIDTH mm 76 92 150<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
38/32 39/33 41/35<br />
9kg - 50mm Polyester<br />
47/36 49/38 50/42<br />
30kg - 75mm Polyester<br />
48/36 49/38 51/42<br />
WALL THICKNESS mm<br />
102 118 176
FRL<br />
- / 60 / 60<br />
FRL<br />
- / 60 / 60<br />
FRL<br />
- / 60 / 60<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
STAGGERED STUD<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
1 x 13mm <strong>BGC</strong> Plasterboard<br />
Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY WIDTH mm 76 92 150<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY WIDTH mm 76 92 150<br />
Rw/Rw+Ctr<br />
41/35 43/37 45/38<br />
52/43 53/43 55/47<br />
53/43 54/43 57/48<br />
115 131 189<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY WIDTH mm 76 92 150<br />
Rw/Rw+Ctr<br />
SS014<br />
40/33 42/36 44/37<br />
50/42 52/42 55/46<br />
50/42 54/42 56/47<br />
115 131 189<br />
SS018<br />
SS019<br />
38/32 39/33 41/34<br />
48/38 49/39 52/44<br />
49/38 50/39 53/45<br />
108 124 182<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
04 / STEEL FRAME INFORMATION<br />
39
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 04 / STEEL FRAME INFORMATION<br />
40<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
STAGGERED STUD<br />
FRL<br />
- / 60 / 60<br />
FRL<br />
- / 120 / 120<br />
FRL<br />
- / 120 / 120<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY WIDTH mm 76 92 150<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
SS020<br />
43/36 44/38 46/39<br />
53/42 54/45 56/48<br />
54/43 55/45 57/49<br />
121 137 195<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY WIDTH mm 76 92 150<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
46/40 47/40 50/42<br />
56/46 57/48 59/52<br />
57/46 58/49 60/52<br />
128 144 202<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY WIDTH mm 76 92 150<br />
Rw/Rw+Ctr<br />
SS021<br />
SS023<br />
47/40 48/41 51/43<br />
57/48 58/49 61/54<br />
58/49 59/50 61/54<br />
140 156 214
FRL<br />
- / 180 / 180<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
STAGGERED STUD<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY WIDTH mm 76 92 150<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
SS026<br />
50/42 51/43 54/45<br />
60/52 61/53 62/56<br />
61/53 61/54 62/57<br />
172 188 246<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 9mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM<br />
CAVITY WIDTH mm 76 92 150<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
SS028<br />
39/31 39/32 41/33<br />
48/37 49/37 52/42<br />
49/37 50/38 54/43<br />
94 110 168<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 10mm <strong>BGC</strong> Soundboard TM<br />
Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
CAVITY WIDTH mm 76 92 150<br />
Rw/Rw+Ctr<br />
SS032<br />
39/32 39/32 41/33<br />
47/36 49/39 52/43<br />
49/37 50/39 54/43<br />
102 118 176<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
04 / STEEL FRAME INFORMATION<br />
41
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 04 / STEEL FRAME INFORMATION<br />
42<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
STAGGERED STUD<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> Plasterboard<br />
Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
CAVITY WIDTH mm 76 92 150<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
35/28 36/29 38/31<br />
45/34 46/35 49/38<br />
46/34 47/35 49/38<br />
95 111 169<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> Plasterboard<br />
Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM<br />
CAVITY WIDTH mm 76 92 150<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
CAVITY WIDTH mm 76 92 150<br />
Rw/Rw+Ctr<br />
SS033<br />
SS034<br />
38/32 39/32 42/35<br />
47/35 49/38 50/42<br />
48/36 49/38 51/40<br />
98 114 172<br />
SS035<br />
36/29 37/30 39/32<br />
46/34 47/36 49/38<br />
47/34 48/36 49/38<br />
95 111 169
FRL<br />
- / - / -<br />
FRL<br />
- / 60 / 60<br />
FRL<br />
120 / 120 / 120<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
STAGGERED STUD<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />
1 x 9mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />
1 x 9mm <strong>BGC</strong> Duraliner TM<br />
CAVITY WIDTH mm 76 92 150<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 9mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY WIDTH mm 76 92 150<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
47/39 48/40 51/43<br />
57/47 58/49 60/52<br />
58/48 59/50 61/53<br />
98 114 172<br />
STAGGERED STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 9mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
PREVIOUSLY <strong>BGC</strong> DL001<br />
Rw/Rw+Ctr<br />
CAVITY WIDTH mm 76 92 150<br />
Rw/Rw+Ctr<br />
SS036<br />
39/31 39/32 41/33<br />
48/37 49/37 52/42<br />
49/38 50/38 53/43<br />
101 117 175<br />
SS041<br />
SS043<br />
47/39 48/40 51/43<br />
57/47 58/49 60/52<br />
58/48 59/50 61/53<br />
98 114 172<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
04 / STEEL FRAME INFORMATION 43
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
DOUBLE STUD<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 10mm <strong>BGC</strong> Plasterboard<br />
Side 2 1 x 10mm <strong>BGC</strong> Plasterboard<br />
SD001<br />
04 / STEEL FRAME INFORMATION 44<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
CAVITY WIDTH mm<br />
148 172 204 320<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
34/28 34/28 35/28 36/28<br />
9kg – 50mm Polyester – 1 side<br />
44/33 45/35 46/37 46/39<br />
9kg – 50mm Polyester – 2 sides<br />
46/35 47/37 48/39 48/41<br />
30kg – 75mm Polyester – 1 side<br />
47/36 49/38 49/40 49/41<br />
30kg – 75mm Polyester – 2 sides<br />
49/36 49/38 49/39 50/42<br />
WALL THICKNESS mm<br />
168 192 224 340<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> Plasterboard<br />
Side 2 1 x 13mm <strong>BGC</strong> Plasterboard<br />
SD002<br />
CAVITY WIDTH mm<br />
148 172 204 320<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
39/33 39/32 40/33 42/34<br />
9kg – 50mm Polyester – 1 side<br />
51/42 52/43 52/44 52/46<br />
9kg – 50mm Polyester – 2 sides<br />
53/43 54/44 54/46 55/48<br />
30kg – 75mm Polyester – 1 side<br />
54/43 54/44 55/46 56/48<br />
30kg – 75mm Polyester – 2 sides<br />
56/45 57/45 57/47 58/49<br />
WALL THICKNESS mm<br />
174 198 230 346<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 10mm <strong>BGC</strong> Soundboard TM<br />
Side 2 1 x 10mm <strong>BGC</strong> Soundboard TM<br />
SD006<br />
CAVITY WIDTH mm<br />
148 172 204 320<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
39/32 39/33 40/33 42/33<br />
9kg – 50mm Polyester – 1 side<br />
51/41 52/43 52/44 52/46<br />
9kg – 50mm Polyester – 2 sides<br />
53/43 54/45 55/46 55/49<br />
30kg – 75mm Polyester – 1 side<br />
54/43 55/45 56/46 56/49<br />
30kg – 75mm Polyester – 2 sides<br />
56/44 57/46 57/47 58/49<br />
WALL THICKNESS mm<br />
168 192 224 340
FRL<br />
- / - / -<br />
FRL<br />
- / 60 / 60<br />
FRL<br />
60 / 60 / 60<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
DOUBLE STUD<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> Soundboard TM<br />
Side 2 1 x 13mm <strong>BGC</strong> Soundboard TM<br />
148 172 204 320<br />
Rw/Rw+Ctr<br />
42/35 42/35 43/36 46/37<br />
54/45 55/47 55/48 56/49<br />
56/45 57/48 57/49 58/49<br />
57/46 57/48 58/49 59/50<br />
59/48 60/49 60/49 61/50<br />
174 198 230 346<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
SD007<br />
SD011<br />
148 172 204 320<br />
Rw/Rw+Ctr<br />
40/34 41/34 42/35 43/35<br />
52/43 52/45 53/45 53/48<br />
54/45 54/46 55/47 55/49<br />
55/46 56/47 57/48 57/49<br />
57/46 58/47 58/48 59/49<br />
174 198 230 346<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />
1 x 10mm <strong>BGC</strong> Plasterboard<br />
Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />
1 x 10mm <strong>BGC</strong> Plasterboard<br />
SD016<br />
148 172 204 320<br />
Rw/Rw+Ctr<br />
46/39 47/39 48/39 49/40<br />
58/48 59/49 59/49 59/50<br />
60/51 61/52 61/53 62/53<br />
61/51 62/52 62/53 63/54<br />
63/52 65/53 65/54 66/55<br />
200 224 256 372<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
04 / STEEL FRAME INFORMATION<br />
45
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 04 / STEEL FRAME INFORMATION<br />
46<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
DOUBLE STUD<br />
FRL<br />
- / 60 / 60<br />
60 / 60 / 60<br />
FRL<br />
- / 120 / 120<br />
90 / 90 / 90<br />
FRL<br />
- / 120 / 120<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
SD019<br />
148 172 204 320<br />
Rw/Rw+Ctr<br />
41/34 41/34 42/35 45/36<br />
53/45 54/46 54/47 55/49<br />
55/46 56/45 56/49 57/51<br />
56/46 56/47 57/49 58/51<br />
58/48 59/49 60/50 61/52<br />
180 204 236 352<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
SD021<br />
148 172 204 320<br />
Rw/Rw+Ctr<br />
48/40 49/41 50/41 53/44<br />
60/51 60/52 61/53 61/55<br />
62/52 62/53 63/55 63/57<br />
63/53 64/54 65/56 65/58<br />
65/58 66/58 67/58 68/60<br />
200 224 256 372<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
SD023<br />
148 172 204 320<br />
Rw/Rw+Ctr<br />
48/40 49/41 51/42 54/44<br />
60/52 61/53 61/54 62/56<br />
62/53 63/54 63/55 64/58<br />
63/53 64/54 64/56 65/58<br />
65/58 66/58 66/58 67/60<br />
212 236 268 384
FRL<br />
- / 60 / 60<br />
FRL<br />
- / 120 / 120<br />
FRL<br />
- / 180 / 180<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
DOUBLE STUD<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
148 172 204 320<br />
Rw/Rw+Ctr<br />
45/38 46/39 47/39 49/40<br />
57/48 57/49 58/49 59/50<br />
59/50 59/51 60/52 61/53<br />
60/50 61/51 62/53 63/54<br />
62/54 63/54 64/54 65/55<br />
187 211 243 359<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
SD024<br />
SD025<br />
148 172 204 320<br />
Rw/Rw+Ctr<br />
54/45 55/46 56/47 59/49<br />
67/58 67/59 68/60 68/62<br />
68/58 68/59 69/61 69/63<br />
69/58 69/60 70/61 71/64<br />
71/59 71/60 72/62 73/65<br />
226 250 282 398<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
SD026<br />
148 172 204 320<br />
Rw/Rw+Ctr<br />
55/46 56/46 57/47 60/49<br />
67/59 68/60 68/61 69/63<br />
69/60 70/61 70/63 71/65<br />
70/60 71/61 71/63 72/65<br />
72/61 73/62 73/63 74/67<br />
244 268 300 416<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
04 / STEEL FRAME INFORMATION<br />
47
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 04 / STEEL FRAME INFORMATION<br />
48<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
DOUBLE STUD<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / 60 / 60<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
148 172 204 320<br />
Rw/Rw+Ctr<br />
38/31 39/32 39/32 41/33<br />
50/40 51/41 51/43 52/45<br />
52/41 53/43 53/44 54/46<br />
53/42 54/43 54/45 55/47<br />
55/43 57/45 57/47 58/49<br />
160 184 216 332<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 9mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM<br />
148 172 204 320<br />
Rw/Rw+Ctr<br />
42/35 43/35 44/36 46/38<br />
54/44 55/45 55/47 56/49<br />
56/46 57/47 57/48 58/49<br />
57/46 58/48 58/49 59/49<br />
59/48 60/49 60/49 62/50<br />
166 190 222 338<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />
1 x 6mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />
1 x 6mm <strong>BGC</strong> Duraliner TM<br />
SD027<br />
SD028<br />
SD038<br />
148 172 204 320<br />
Rw/Rw+Ctr<br />
46/38 46/38 48/39 49/39<br />
58/48 58/49 59/49 59/50<br />
60/50 61/51 62/52 62/53<br />
61/50 62/51 63/53 64/54<br />
63/52 64/52 65/53 66/55<br />
186 210 242 358
FRL<br />
- / 60 / 60<br />
FRL<br />
120 / 120 / 120<br />
STEEL FRAME INTERIOR WALL SYSTEM<br />
DOUBLE STUD<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
SD042<br />
148 172 204 320<br />
Rw/Rw+Ctr<br />
48/40 49/40 50/41 51/42<br />
60/51 60/52 61/53 61/55<br />
62/52 62/53 63/54 63/57<br />
63/53 64/54 65/55 65/58<br />
65/56 66/56 66/56 67/59<br />
192 216 248 364<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 9mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
PREVIOUSLY <strong>BGC</strong> DL001<br />
SD043<br />
148 172 204 320<br />
Rw/Rw+Ctr<br />
48/39 49/40 50/41 53/43<br />
60/51 61/52 61/53 61/55<br />
62/52 63/53 63/55 64/57<br />
63/52 63/53 64/55 65/58<br />
65/54 66/55 67/57 68/60<br />
198 222 254 370<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
04 / STEEL FRAME INFORMATION<br />
49
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 04 / STEEL FRAME INFORMATION<br />
50<br />
<strong>BGC</strong> CINEMA WALL SYSTEM<br />
SYSTEM SET OUT<br />
• Top hat sections (50mm x 35mm x 1.15m) fixed<br />
vertically at 900mm max centres to engineers design<br />
<strong>and</strong> supported at the head <strong>and</strong> the base with tracks<br />
• The span of the Top hats between girts shall be<br />
nominally 1.9m for single spans <strong>and</strong> 2.7m for<br />
continuous spans. To be confirmed as suitable<br />
by the engineer for internal wind pressures.<br />
• Steel columns <strong>and</strong> girts to be engineer specified<br />
• Girts to be fixed to vertical steel columns using<br />
proprietarty isolation mounts that include a<br />
through bolt<br />
FRL<br />
120 / 120 / 120<br />
FRL<br />
120 / 120 / 120<br />
MIN CAVITY mm<br />
CAVITY INFILL<br />
2 x Bradford Glasswool 110 (R2.5)<br />
2 x Autex AAB32-100<br />
2 x 30kg - 75mm Polyester<br />
WALL THICKNESS<br />
MIN CAVITY WIDTH mm<br />
CAVITY INFILL<br />
2 x Bradford Glasswool 110 (R2.5)<br />
2 x Autex AAB32-100<br />
2 x 30kg - 75mm Polyester<br />
WALL THICKNESS<br />
PLASTERBOARD FIXINGS<br />
• Layer 1 to Top hat – 30mm bugle head screws<br />
at 600mm centres<br />
• Layer 2 to Top hat – 45mm bugle head screws<br />
at 300mm centres <strong>and</strong> laminating screws at 300mm<br />
centres 200mm from top <strong>and</strong> bottom<br />
• Layer 3 to layer 2 – 38mm laminating screws at<br />
400mm x 400mm grid<br />
• Layer 4 to layer 3 – 38mm laminating screws at<br />
400mm x 400mm grid<br />
• 2 layers glasswool or polyester insulation.<br />
Refer to insulation in system specification<br />
• Perimeters to be caulked with fire rated caulking<br />
to a depth of 30mm x 10mm wide when used<br />
with a backing rod<br />
• Vertical control joints to be caulked to a depth of<br />
16mm backed with plaster<br />
STEEL TOP HATS AT 900mm MAX CENTRES<br />
Side 1 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
STEEL TOP HATS AT 900mm MAX CENTRES<br />
Side 1 4 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 4 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
375<br />
Rw<br />
75/68<br />
75/68<br />
74/67<br />
471<br />
375<br />
Rw<br />
79/72<br />
79/72<br />
78/71<br />
503<br />
SC001<br />
SC002
STEEL FRAME WITH ONE LAYER <strong>BGC</strong> FIREBOARD -<br />
VERTICAL SHEETING<br />
SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING<br />
FRAMING<br />
Lightweight Steel up to<br />
0.8mm<br />
Lightweight Steel 0.8mm<br />
to 1.6mm<br />
FIREBOARD THICKNESS<br />
13mm<br />
16mm<br />
13mm<br />
16mm<br />
STEEL FRAME WITH ONE LAYER <strong>BGC</strong> FIREBOARD -<br />
HORIZONTAL SHEETING<br />
INSTALLATION DETAILS<br />
STEEL STUD<br />
FIXING SPECIFICATIONS<br />
FASTENER SPACING<br />
300mm max. centres<br />
300mm max. centres<br />
200mm max. centres<br />
300mm max. centres<br />
SCREW TYPE<br />
No 6 Type S Needle Point<br />
No 6 Type S Needle Point<br />
No 6 Type D Drill Point<br />
No 6 Type D Drill Point<br />
SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING<br />
FRAMING<br />
Lightweight Steel up to<br />
0.8mm<br />
Lightweight Steel 0.8mm<br />
to 1.6mm<br />
FIREBOARD THICKNESS<br />
13mm<br />
16mm<br />
13mm<br />
16mm<br />
SCREW TYPE<br />
No 6 Type S Needle Point<br />
No 6 Type S Needle Point<br />
No 6 Type D Drill Point<br />
No 6 Type D Drill Point<br />
POSITION<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints<br />
Corners & Openings<br />
SCREW LENGTH<br />
1ST LAYER<br />
25mm<br />
30mm<br />
32mm<br />
32mm<br />
FIXING SPECIFICATIONS<br />
FASTENER SPACING<br />
300mm max. centres<br />
At each stud<br />
200mm max. centres<br />
300mm max. centres<br />
POSITION<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints<br />
Corners & Openings<br />
SCREW LENGTH<br />
1ST LAYER<br />
25mm<br />
30mm<br />
32mm<br />
32mm<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
04 / STEEL FRAME INFORMATION<br />
51
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 04 / STEEL FRAME INFORMATION<br />
52<br />
INSTALLATION DETAILS<br />
STEEL STUD<br />
STEEL FRAME WITH TWO LAYERS <strong>BGC</strong> FIREBOARD - VERTICAL SHEETING<br />
SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING<br />
FRAMING<br />
Lightweight Steel up to<br />
0.8mm<br />
Lightweight Steel 0.8mm<br />
to 1.6mm<br />
FIREBOARD THICKNESS<br />
13mm<br />
16mm<br />
13mm<br />
16mm<br />
STEEL FRAME WITH TWO LAYERS <strong>BGC</strong> FIREBOARD -<br />
FIRST LAYER VERTICAL, SECOND LAYER HORIZONTAL<br />
FIXING SPECIFICATIONS<br />
FIRST LAYER<br />
FASTENER SPACING<br />
600mm max. centres<br />
600mm max. centres<br />
600mm max. centres<br />
300mm max. centres<br />
300mm max. centres<br />
200mm max. centres<br />
300mm max. centres<br />
SCREW TYPE<br />
No 6 Type S Needle Point<br />
No 6 Type S Needle Point<br />
No 6 Type D Drill Point<br />
No 6 Type D Drill Point<br />
SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING<br />
FRAMING<br />
Lightweight Steel up to<br />
0.8mm<br />
Lightweight Steel 0.8mm<br />
to 1.6mm<br />
FIREBOARD THICKNESS<br />
13mm<br />
16mm<br />
13mm<br />
16mm<br />
FASTENER SPACING<br />
600mm max. centres<br />
600mm max. centres<br />
600mm max. centres<br />
SECOND LAYER<br />
LOCATION<br />
Centre of the Board<br />
Recessed Edges<br />
Corners & Openings<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints<br />
Corners & Openings<br />
FIXING SPECIFICATIONS<br />
FIRST LAYER<br />
300mm max. centres<br />
At Each Stud<br />
200mm max. centres<br />
300mm max. centres<br />
SCREW TYPE<br />
No 6 Type S Needle Point<br />
No 6 Type S Needle Point<br />
No 6 Type D Drill Point<br />
No 6 Type D Drill Point<br />
SECOND LAYER<br />
SCREW LENGTH<br />
1ST LAYER<br />
25mm<br />
30mm<br />
32mm<br />
32mm<br />
2ND LAYER<br />
45mm<br />
45mm<br />
45mm<br />
45mm<br />
LOCATION<br />
Centre of the Board<br />
Recessed Edges<br />
Corners & Openings<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints<br />
Corners & Openings<br />
SCREW LENGTH<br />
1ST LAYER<br />
25mm<br />
30mm<br />
32mm<br />
32mm<br />
2ND LAYER<br />
45mm<br />
45mm<br />
45mm<br />
45mm
STEEL FRAME WITH THREE LAYERS <strong>BGC</strong> FIREBOARD -<br />
VERTICAL SHEETING<br />
INSTALLATION DETAILS<br />
STEEL STUD<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
FIXING SPECIFICATIONS THREE LAYER<br />
VERTICAL(Shown)<br />
FIRST LAYER<br />
FASTENER SPACING<br />
600mm max. centres<br />
600mm max. centres<br />
600mm max. centres<br />
300mm max. centres<br />
300mm max. centres<br />
200mm max. centres<br />
300mm max. centres<br />
Laminating Screws at<br />
400mm max. grid<br />
SECOND LAYER<br />
THIRD LAYER<br />
LOCATION<br />
Centre of the Board<br />
Recessed Edges<br />
Corners & Openings<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints<br />
Corners & Openings<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints<br />
Corners & Openings<br />
SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING<br />
FRAMING<br />
Lightweight Steel up to<br />
0.8mm<br />
Lightweight Steel 0.8mm<br />
to 1.6mm<br />
FIREBOARD THICKNESS<br />
13mm<br />
16mm<br />
13mm<br />
16mm<br />
FIXING SPECIFICATIONS<br />
THREE LAYER HORIZONTAL<br />
FIRST LAYER<br />
FASTENER SPACING<br />
600mm max. centres<br />
600mm max. centres<br />
600mm max. centres<br />
300mm max. centres<br />
600mm max. centres<br />
200mm max. centres<br />
300mm max. centres<br />
Laminating Screws at<br />
400mm max. grid<br />
SCREW TYPE<br />
No 6 Type S Needle Point<br />
No 6 Type S Needle Point<br />
No 6 Type D Drill Point<br />
No 6 Type D Drill Point<br />
SECOND LAYER<br />
THIRD LAYER<br />
LOCATION<br />
Centre of the Board<br />
Recessed Edges<br />
Corners & Openings<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints<br />
Corners & Openings<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints<br />
Corners & Openings<br />
SCREW LENGTH<br />
1ST LAYER<br />
25mm<br />
30mm<br />
32mm<br />
32mm<br />
2ND LAYER<br />
45mm<br />
45mm<br />
45mm<br />
45mm<br />
04 / STEEL FRAME INFORMATION 53
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 04 / STEEL FRAME INFORMATION<br />
54<br />
INSTALLATION DETAILS<br />
STEEL STUD<br />
LOAD BEARING WALL 60/60/60<br />
Note: Refer to page 10 for screw lengths.<br />
SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING<br />
FRAMING<br />
Lightweight Steel up to<br />
0.8mm<br />
Lightweight Steel 0.8mm<br />
to 1.6mm<br />
FIREBOARD THICKNESS<br />
13mm<br />
16mm<br />
13mm<br />
16mm<br />
SCREW TYPE<br />
No 6 Type S Needle Point<br />
No 6 Type S Needle Point<br />
No 6 Type D Drill Point<br />
No 6 Type D Drill Point<br />
FIXING SPECIFICATIONS<br />
FASTENER SPACING<br />
300mm max. centres<br />
At each stud<br />
100mm max. centres<br />
300mm max. centres<br />
SCREW LENGTH<br />
1ST LAYER<br />
25mm<br />
30mm<br />
32mm<br />
32mm<br />
POSITION<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints<br />
Corners & Openings
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
TIMBER FRAME INTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 1 x 10mm <strong>BGC</strong> Plasterboard<br />
Side 2 1 x 10mm <strong>BGC</strong> Plasterboard<br />
70 90 120 140<br />
Rw/Rw+Ctr<br />
31/25 32/26 33/27 33/27<br />
37/28 37/28 38/30 39/32<br />
37/28 38/29 39/30 39/32<br />
90 110 140 160<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> Plasterboard<br />
Side 2 1 x 13mm <strong>BGC</strong> Plasterboard<br />
70 90 120 140<br />
Rw/Rw+Ctr<br />
34/28 35/30 36/30 37/31<br />
39/32 40/32 41/35 41/35<br />
40/32 40/32 41/35 41/35<br />
96 116 146 166<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 2 x 10mm <strong>BGC</strong> Plasterboard<br />
Side 2 2 x 10mm <strong>BGC</strong> Plasterboard<br />
T001<br />
T002<br />
T004<br />
70 90 120 140<br />
Rw/Rw+Ctr<br />
39/31 39/33 40/33 41/34<br />
44/36 45/37 45/40 45/40<br />
44/36 45/38 45/40 46/40<br />
90 110 140 160<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
05 / TIMBER FRAME INFORMATION<br />
55
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 05 / TIMBER FRAME INFORMATION<br />
56<br />
TIMBER FRAME INTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 2 x 13mm <strong>BGC</strong> Plasterboard<br />
Side 2 2 x 13mm <strong>BGC</strong> Plasterboard<br />
70 90 120 140<br />
Rw/Rw+Ctr<br />
41/35 43/37 43/37 44/37<br />
46/41 47/42 47/42 47/43<br />
46/41 47/42 47/43 47/43<br />
122 142 172 192<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 1 x 10mm <strong>BGC</strong> Soundboard TM<br />
Side 2 1 x 10mm <strong>BGC</strong> Soundboard TM<br />
T005<br />
T006<br />
70 90 120 140<br />
Rw/Rw+Ctr<br />
34/29 35/29 35/29 36/30<br />
39/31 39/32 40/35 40/34<br />
39/31 39/32 40/35 40/35<br />
90 110 140 160<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> Soundboard TM<br />
Side 2 1 x 13mm <strong>BGC</strong> Soundboard TM<br />
T007<br />
STUD DEPTH mm 70 90 120 140<br />
Rw/Rw+Ctr<br />
36/31 37/31 38/33 38/33<br />
40/34 40/36 40/37 40/37<br />
40/34 41/36 41/37 41/38<br />
96 116 146 166
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / 60 / 60<br />
60 / 60 / 60<br />
TIMBER FRAME INTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
STUD DEPTH mm 70 90 120 140<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
35/29 35/29 36/30 37/30<br />
9kg - 50mm Polyester<br />
39/31 40/31 41/35 41/34<br />
30kg - 75mm Polyester<br />
39/31 40/32 41/35 41/35<br />
WALL THICKNESS mm<br />
90 110 140 160<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 2 x 10mm <strong>BGC</strong> Soundboard TM<br />
Side 2 2 x 10mm <strong>BGC</strong> Soundboard TM<br />
STUD DEPTH mm 70 90 120 140<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 1 x 10mm <strong>BGC</strong> Soundboard TM<br />
Side 2 1 x 10mm <strong>BGC</strong> WR Plasterboard<br />
Rw/Rw+Ctr<br />
43/37 44/37 44/38 45/39<br />
47/41 48/43 48/44 48/44<br />
47/42 48/43 48/44 48/44<br />
110 130 160 180<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
PREVIOUSLY <strong>BGC</strong> 005<br />
T008<br />
T010<br />
T011<br />
STUD DEPTH mm 70 90 120 140<br />
Rw/Rw+Ctr<br />
35/30 36/31 37/32 38/33<br />
40/32 41/35 41/36 41/37<br />
40/33 41/35 41/36 42/37<br />
96 116 146 166<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
05 / TIMBER FRAME INFORMATION<br />
57
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
TIMBER FRAME INTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> Plasterboard<br />
Side 2 1 x 10mm <strong>BGC</strong> Plasterboard<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
T015<br />
05 / TIMBER FRAME INFORMATION 58<br />
FRL<br />
- / - / -<br />
FRL<br />
- / 60 / 60<br />
60 / 60 / 60<br />
FRL<br />
- / 120 / 120<br />
STUD DEPTH mm 70 90 120 140<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
37/31 37/31 39/33 39/32<br />
9kg - 50mm Polyester<br />
41/33 42/36 43/37 43/38<br />
30kg - 75mm Polyester<br />
42/33 42/37 43/38 43/39<br />
WALL THICKNESS mm<br />
106 126 156 176<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
PREVIOUSLY <strong>BGC</strong> 007<br />
T019<br />
STUD DEPTH mm<br />
70 90 120 140<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
36/31<br />
40/34<br />
40/34<br />
102<br />
37/31<br />
40/36<br />
41/36<br />
122<br />
38/33<br />
40/37<br />
41/37<br />
152<br />
38/33<br />
40/37<br />
41/38<br />
172<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
T021<br />
STUD DEPTH mm<br />
70 90 120 140<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
44/39<br />
48/43<br />
48/43<br />
122<br />
44/39<br />
48/44<br />
48/44<br />
142<br />
45/40<br />
48/45<br />
48/45<br />
172<br />
46/40<br />
48/45<br />
48/45<br />
192
TIMBER FRAME INTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
T022<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
FRL<br />
60 / 60 / 60<br />
FRL<br />
- / 120 / 120<br />
FRL<br />
- / 180 / 180<br />
STUD DEPTH mm<br />
70 90 120 140<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
40/35<br />
44/39<br />
44/39<br />
122<br />
41/37<br />
44/40<br />
44/41<br />
142<br />
42/37<br />
44/41<br />
44/41<br />
172<br />
42/37<br />
44/41<br />
44/41<br />
192<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
T023<br />
STUD DEPTH mm<br />
70 90 120 140<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
45/40<br />
48/45<br />
48/45<br />
134<br />
46/40<br />
48/45<br />
48/45<br />
154<br />
46/41<br />
48/45<br />
48/45<br />
184<br />
47/42<br />
48/45<br />
48/45<br />
204<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
T026<br />
STUD DEPTH mm 70 90 120 140<br />
CAVITY INFILL<br />
Rw/Rw+Ctr<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
134 154 184 204<br />
05 / TIMBER FRAME INFORMATION 59
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
TIMBER FRAME INTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
T027<br />
05 / TIMBER FRAME INFORMATION 60<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
60 / 60 / 60<br />
STUD DEPTH mm 70 90 120 140<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
PREVIOUSLY <strong>BGC</strong> DL003<br />
Rw/Rw+Ctr<br />
33/26 33/26 34/27 34/27<br />
40/30 41/31 42/34 42/34<br />
40/30 41/31 43/34 43/34<br />
82 102 132 152<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 1 x 10mm <strong>BGC</strong> Soundboard TM (against stud)<br />
1 x 6mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 10mm <strong>BGC</strong> Soundboard TM (against stud)<br />
1 x 6mm <strong>BGC</strong> Duraliner TM<br />
T037<br />
STUD DEPTH mm 70 90 120 140<br />
Rw/Rw+Ctr<br />
41/34 42/36 43/36 43/36<br />
46/39 47/41 47/42 47/42<br />
46/39 47/41 47/42 47/43<br />
102 122 152 172<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
T039<br />
STUD DEPTH mm 70 90 120 140<br />
Rw/Rw+Ctr<br />
42/36 43/37 44/38 44/38<br />
47/41 47/43 48/43 48/44<br />
47/41 48/43 48/44 48/44<br />
108 128 158 178
FRL<br />
90 / 90 / 90<br />
FRL<br />
- / 180 / 180<br />
FRL<br />
- / 60 / 60<br />
TIMBER FRAME INTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
PREVIOUSLY <strong>BGC</strong> DL004<br />
T042<br />
STUD DEPTH mm 70 90 120 140<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
44/39 45/39 46/40 46/40<br />
48/43 48/44 48/45 48/45<br />
48/43 48/44 48/45 48/45<br />
114 134 164 184<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1 2 x 16mm Wet Area <strong>Fire</strong>board<br />
Side 2 2 x 16mm Wet Area <strong>Fire</strong>board<br />
T044<br />
70 90 120 140<br />
Rw/Rw+Ctr<br />
45/40 46/40 46/41 47/42<br />
48/45 48/45 48/45 48/45<br />
48/45 48/45 48/45 48/45<br />
114 134 164 184<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1<br />
Side 2 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
STUD DEPTH mm 70 90 120 140<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
T046<br />
Rw/Rw+Ctr<br />
35/32 - - -<br />
- - - -<br />
- - - -<br />
102 122 152 172<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
05 / TIMBER FRAME INFORMATION<br />
61
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 05 / TIMBER FRAME INFORMATION<br />
62<br />
TIMBER FRAME INTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
FRL<br />
- / 90 / 90<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINGS AT 1350mm MAX CENTRES<br />
Side 1<br />
Side 2 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
STUD DEPTH mm 70 90 120 140<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
T048<br />
Rw/Rw+Ctr<br />
38/36 - - -<br />
- - - -<br />
- - - -<br />
118 138 168 188
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / 60 / 60<br />
TIMBER FRAME INTERIOR WALL SYSTEM<br />
STAGGERED STUD<br />
STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />
MIN 20mm CLEARANCE BETWEEN STUD AND<br />
OPPOSING WALL LINING<br />
Side 1 1 x 10mm <strong>BGC</strong> Soundboard TM<br />
Side 2 1 x 10mm <strong>BGC</strong> Soundboard TM<br />
PLATE WIDTH mm 90 120 140<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
33/27 34/28 35/29<br />
43/34 45/38 45/37<br />
44/34 46/38 46/38<br />
110 140 160<br />
STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />
MIN 20mm CLEARANCE BETWEEN STUD AND<br />
OPPOSING WALL LINING<br />
Side 1 2 x 10mm <strong>BGC</strong> Soundboard TM<br />
Side 2 2 x 10mm <strong>BGC</strong> Soundboard TM<br />
PLATE WIDTH mm 90 120 140<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
42/35 43/36 44/36<br />
52/45 52/46 53/47<br />
52/45 53/47 53/47<br />
130 160 180<br />
STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />
MIN 20mm CLEARANCE BETWEEN STUD AND<br />
OPPOSING WALL LINING<br />
Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
PLATE WIDTH mm 90 120 140<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
TS006<br />
TS010<br />
TS011<br />
35/29 37/31 37/32<br />
45/37 46/38 46/40<br />
45/37 46/39 47/40<br />
116 146 166<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
05 / TIMBER FRAME INFORMATION<br />
63
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 05 / TIMBER FRAME INFORMATION<br />
64<br />
TIMBER FRAME INTERIOR WALL SYSTEM<br />
STAGGERED STUD<br />
FRL<br />
- / 90 / 90<br />
FRL<br />
- / 120 / 120<br />
FRL<br />
- / 120 / 120<br />
STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />
MIN 20mm CLEARANCE BETWEEN STUD AND<br />
OPPOSING WALL LINING<br />
Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
PLATE WIDTH mm 90 120 140<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
36/30 38/32 38/32<br />
46/39 46/40 46/41<br />
46/39 46/40 47/42<br />
122 152 172<br />
STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />
MIN 20mm CLEARANCE BETWEEN STUD AND<br />
OPPOSING WALL LINING<br />
Side 1 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
PLATE WIDTH mm 90 120 140<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
42/36 43/37 44/37<br />
52/46 53/48 53/48<br />
53/47 53/48 53/49<br />
142 172 192<br />
STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />
MIN 20mm CLEARANCE BETWEEN STUD AND<br />
OPPOSING WALL LINING<br />
Side 1 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
PLATE WIDTH mm 90 120 140<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
TS019<br />
TS021<br />
TS023<br />
43/37 45/38 45/38<br />
53/48 53/49 53/49<br />
53/49 53/50 53/50<br />
154 184 204
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
TIMBER FRAME INTERIOR WALL SYSTEM<br />
STAGGERED STUD<br />
STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />
MIN 20mm CLEARANCE BETWEEN STUD AND<br />
OPPOSING WALL LINING<br />
Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
PLATE WIDTH mm 90 120 140<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />
MIN 20mm CLEARANCE BETWEEN STUD AND<br />
OPPOSING WALL LINING<br />
Side 1 1 x 9mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM<br />
PLATE WIDTH mm 90 120 140<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />
MIN 20mm CLEARANCE BETWEEN STUD AND<br />
OPPOSING WALL LINING<br />
Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 10mm <strong>BGC</strong> Plasterboard<br />
PLATE WIDTH mm 90 120 140<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
Rw/Rw+Ctr<br />
37/30 39/32 39/31<br />
47/38 48/39 48/40<br />
47/38 48/40 48/40<br />
108 138 158<br />
Rw/Rw+Ctr<br />
TS027<br />
33/26 33/25 33/26<br />
43/31 45/35 45/35<br />
43/31 45/35 46/35<br />
102 132 152<br />
TS028<br />
TS030<br />
32/25 33/26 33/26<br />
42/31 44/34 45/36<br />
43/31 45/34 46/35<br />
106 136 156<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
05 / TIMBER FRAME INFORMATION<br />
65
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 05 / TIMBER FRAME INFORMATION<br />
66<br />
TIMBER FRAME INTERIOR WALL SYSTEM<br />
STAGGERED STUD<br />
FRL<br />
- / - / -<br />
FRL<br />
60 / 60 / 60<br />
FRL<br />
60 / 60 / 60<br />
STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />
MIN 20mm CLEARANCE BETWEEN STUD AND<br />
OPPOSING WALL LINING<br />
Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 10mm <strong>BGC</strong> Soundboard TM<br />
PLATE WIDTH mm 90 120 140<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />
MIN 20mm CLEARANCE BETWEEN STUD AND<br />
OPPOSING WALL LINING<br />
Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
PLATE WIDTH mm 90 120 140<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
42/34 43/35 43/36<br />
52/46 53/47 53/47<br />
53/46 53/47 53/47<br />
128 158 178<br />
STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />
MIN 20mm CLEARANCE BETWEEN STUD AND<br />
OPPOSING WALL LINING<br />
Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />
1 x 6mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />
1 x 6mm <strong>BGC</strong> Duraliner TM<br />
PLATE WIDTH mm 90 120 140<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
Rw/Rw+Ctr<br />
Rw/Rw+Ctr<br />
TS031<br />
33/26 33/26 34/27<br />
43/32 45/36 45/35<br />
43/32 46/36 46/36<br />
106 136 156<br />
TS039<br />
TS040<br />
42/34 43/36 44/36<br />
52/46 53/48 53/48<br />
53/47 53/48 53/49<br />
134 164 184
FRL<br />
90 / 90 / 90<br />
TIMBER FRAME INTERIOR WALL SYSTEM<br />
STAGGERED STUD<br />
STAGGERED TIMBER STUDS AT 600mm MAX CENTRES<br />
MIN 20mm CLEARANCE BETWEEN STUD AND<br />
OPPOSING WALL LINING<br />
Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
PREVIOUSLY <strong>BGC</strong> DL004<br />
PLATE WIDTH mm 90 120 140<br />
Rw/Rw+Ctr<br />
TS042<br />
42/34 43/36 44/36<br />
52/46 53/48 53/48<br />
53/47 53/48 53/49<br />
134 164 184<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
05 / TIMBER FRAME INFORMATION<br />
67
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 05 / TIMBER FRAME INFORMATION<br />
68<br />
TIMBER FRAME INTERIOR WALL SYSTEM<br />
DOUBLE STUD<br />
FRL<br />
- / 60 / 60<br />
FRL<br />
- / 60 / 60<br />
FRL<br />
- / 60 / 60<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
160 200 260 300<br />
Rw/Rw+Ctr<br />
40/34 42/35 43/35 44/36<br />
52/44 53/45 53/47 53/47<br />
54/45 55/47 55/48 55/49<br />
55/45 56/48 56/48 56/49<br />
57/46 58/48 59/49 59/49<br />
186 226 286 326<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 13mm <strong>BGC</strong> Plasterboard (against stud)<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 13mm <strong>BGC</strong> Plasterboard (against stud)<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
TD011<br />
TD013<br />
160 200 260 300<br />
Rw/Rw+Ctr<br />
46/37 47/38 48/38 49/39<br />
57/48 57/49 58/49 58/51<br />
60/50 61/52 61/53 61/53<br />
61/50 61/52 62/54 62/55<br />
63/52 64/54 65/55 65/55<br />
212 252 312 352<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 10mm <strong>BGC</strong> Plasterboard (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 10mm <strong>BGC</strong> Plasterboard (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
TD017<br />
CAVITY WIDTH mm 160 200 260 300<br />
Rw/Rw+Ctr<br />
Nil<br />
46/38 47/39 48/39 49/40<br />
9kg – 50mm Polyester – 1 side<br />
57/49 58/49 58/49 58/51<br />
9kg – 50mm Polyester – 2 sides<br />
60/51 61/52 61/53 61/53<br />
30kg – 75mm Polyester – 1 side<br />
61/51 62/53 63/54 63/55<br />
30kg – 75mm Polyester – 2 sides<br />
63/52 64/54 65/55 65/55<br />
WALL THICKNESS mm<br />
212 252 312 352
FRL<br />
- / 60 / 60<br />
60 / 60 / 60<br />
FRL<br />
- / 120 / 120<br />
FRL<br />
- / 120 / 120<br />
TIMBER FRAME INTERIOR WALL SYSTEM<br />
DOUBLE STUD<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
160 200 260 300<br />
Rw/Rw+Ctr<br />
42/35 43/36 45/37 45/37<br />
54/46 55/48 55/49 55/49<br />
56/48 57/49 57/49 57/50<br />
57/48 58/49 58/49 58/51<br />
59/48 60/49 61/50 61/51<br />
192 232 292 332<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
160 200 260 300<br />
Rw/Rw+Ctr<br />
48/40 50/41 51/43 52/43<br />
60/51 60/53 61/55 61/55<br />
62/53 63/55 63/56 63/57<br />
63/53 64/55 64/56 64/57<br />
65/54 65/55 66/57 66/58<br />
212 252 312 352<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
TD019<br />
TD021<br />
TD023<br />
160 200 260 300<br />
Rw/Rw+Ctr<br />
48/39 49/41 51/42 52/43<br />
60/52 61/54 61/55 61/56<br />
62/54 63/55 64/57 64/57<br />
63/54 64/56 65/57 65/58<br />
65/54 66/57 67/58 67/59<br />
224 264 324 364<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
05 / TIMBER FRAME INFORMATION<br />
69
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 05 / TIMBER FRAME INFORMATION<br />
70<br />
TIMBER FRAME INTERIOR WALL SYSTEM<br />
DOUBLE STUD<br />
FRL<br />
- / 120 / 120<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />
Side 1 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
160 200 260 300<br />
Rw/Rw+Ctr<br />
54/45 56/46 58/48 59/49<br />
67/59 68/61 69/62 69/63<br />
69/61 70/62 71/64 71/65<br />
70/61 71/63 72/64 72/65<br />
72/61 73/63 73/65 73/65<br />
256 296 356 396<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
160 200 260 300<br />
Rw/Rw+Ctr<br />
38/30 38/31 39/32 40/32<br />
51/41 51/43 52/44 52/45<br />
52/42 53/45 54/46 54/46<br />
53/42 54/45 55/47 55/47<br />
55/43 56/46 57/48 57/49<br />
172 212 272 312<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 9mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 9mm <strong>BGC</strong> Duraliner TM<br />
TD026<br />
TD027<br />
TD028<br />
160 200 260 300<br />
Rw/Rw+Ctr<br />
42/34 43/35 44/36 45/36<br />
55/45 55/46 56/48 56/48<br />
56/46 57/48 58/49 58/50<br />
58/47 58/49 58/49 58/51<br />
59/47 60/49 61/49 61/52<br />
178 218 278 318
FRL<br />
60 / 60 / 60<br />
FRL<br />
60 / 60 / 60<br />
FRL<br />
90 / 90 / 90<br />
TIMBER FRAME INTERIOR WALL SYSTEM<br />
DOUBLE STUD<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
CAVITY WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg – 50mm Polyester – 1 side<br />
9kg – 50mm Polyester – 2 sides<br />
30kg – 75mm Polyester – 1 side<br />
30kg – 75mm Polyester – 2 sides<br />
WALL THICKNESS mm<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
PREVIOUSLY <strong>BGC</strong> DL003<br />
160 200 260 300<br />
Rw/Rw+Ctr<br />
46/38 47/39 48/39 49/40<br />
58/49 59/49 59/49 59/51<br />
60/50 60/52 61/53 61/53<br />
61/51 62/53 63/54 63/54<br />
63/52 64/53 65/55 65/55<br />
198 238 298 338<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />
1 x 6mm <strong>BGC</strong> Duraliner TM<br />
Side 2 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board (against studs)<br />
1 x 6mm <strong>BGC</strong> Duraliner TM<br />
160 200 260 300<br />
Rw/Rw+Ctr<br />
48/39 49/40 51/41 52/42<br />
60/51 61/53 61/54 61/55<br />
62/53 63/54 63/56 63/57<br />
63/53 64/54 64/56 64/57<br />
65/53 65/55 66/57 66/58<br />
204 244 304 344<br />
MIN 20mm GAP BETWEEN STUD WALLS<br />
2 ROWS OF TIMBER STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Side 2 1 x 6mm <strong>BGC</strong> Duraliner TM (against studs)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
PREVIOUSLY <strong>BGC</strong> DL004<br />
TD039<br />
TD040<br />
TD042<br />
160 200 260 300<br />
Rw/Rw+Ctr<br />
48/39 49/40 51/41 52/42<br />
60/51 61/53 61/54 61/55<br />
62/53 63/54 63/56 63/57<br />
63/53 64/54 64/56 64/57<br />
65/53 65/55 66/57 66/58<br />
204 244 304 344<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
05 / TIMBER FRAME INFORMATION<br />
71
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 05 / TIMBER FRAME INFORMATION<br />
72<br />
INSTALLATION DETAILS<br />
TIMBER STUD<br />
TIMBER FRAME WITH ONE LAYER <strong>BGC</strong> FIREBOARD -<br />
HORIZONTAL SHEETING<br />
TIMBER FRAME WITH ONE LAYER <strong>BGC</strong> FIREBOARD -<br />
VERTICAL SHEETING<br />
SCREW FIXINGS FOR SOFT WOOD TIMBER FRAMING<br />
FRAMING<br />
Soft Wood Timber<br />
FIREBOARD THICKNESS<br />
13mm<br />
16mm<br />
FIXING SPECIFICATIONS<br />
FASTENER SPACING<br />
2 Nails 50mm apart at<br />
300mm max. centres<br />
1 screw at 200mm<br />
max. centres<br />
At Each Stud<br />
Nails at 150mm max.<br />
centres Screws at<br />
200mm max. centres<br />
Nails at 150mm<br />
max. centres Screws<br />
at 200mm max.<br />
centres<br />
FASTENER SPACING<br />
2 Nails 50mm apart at<br />
300mm max. centres<br />
1 screw at 200mm<br />
max. centres<br />
At Each Stud<br />
Nails at 150mm max.<br />
centres Screws at<br />
200mm max. centres<br />
Nails at 150mm<br />
max. centres Screws<br />
at 200mm max.<br />
centres<br />
SCREW TYPE<br />
No 6 Type W<br />
No 6 Type W<br />
LOCATION<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints<br />
Corners & Openings<br />
FIXING SPECIFICATIONS<br />
LOCATION<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints<br />
Corners & Openings<br />
SCREW LENGTH<br />
1ST LAYER<br />
32mm<br />
45mm
TIMBER FRAME WITH TWO LAYERS <strong>BGC</strong> FIREBOARD -<br />
HORIZONTAL SHEETING<br />
SCREW FIXINGS FOR SOFT WOOD TIMBER FRAMING<br />
FRAMING<br />
Soft Wood Timber<br />
FIREBOARD THICKNESS<br />
13mm<br />
16mm<br />
INSTALLATION DETAILS<br />
TIMBER STUD<br />
FASTENER SPACING<br />
Nails or Screws<br />
600mm max. centres<br />
Nails or Screws<br />
600mm max. centres<br />
Nails or Screws<br />
600mm max. centres<br />
in stagered pattern<br />
2 Nails 50mm apart at<br />
300mm max. centres<br />
1 screw at 200mm<br />
max. centres<br />
Nails or screws at<br />
300mm max. centres<br />
Nails at 150mm max.<br />
centres Screws at<br />
200mm max. centres<br />
Nails at 150mm<br />
max. centres Screws<br />
at 300mm max.<br />
centres<br />
SCREW TYPE<br />
No 6 Type W<br />
No 6 Type W<br />
FIXING SPECIFICATIONS<br />
FIRST LAYER<br />
SECOND LAYER<br />
LOCATION<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints<br />
on noggins<br />
Corners & Openings<br />
SCREW LENGTH<br />
1ST LAYER<br />
32mm<br />
45mm<br />
2ND LAYER<br />
50mm<br />
65mm<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
05 / TIMBER FRAME INFORMATION<br />
73
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 05 / TIMBER FRAME INFORMATION<br />
74<br />
INSTALLATION DETAILS<br />
TIMBER STUD<br />
TIMBER FRAME WITH THREE LAYERS <strong>BGC</strong> FIREBOARD -<br />
VERTICAL SHEETING<br />
FIXING SPECIFICATIONS<br />
THREE LAYER HORIZONTAL<br />
FIRST LAYER<br />
FASTENER SPACING<br />
600mm max. centres<br />
Fasteners at each stud<br />
600mm max. centres<br />
2 nails 50mm apart at<br />
300mm max. centre<br />
1 scew at 200mm max.<br />
centres<br />
Fasteners at each stud<br />
Nails 300mm max<br />
Screws 150mm max<br />
centres<br />
Laminating Screws at<br />
400mm max. grid<br />
Laminating Screws<br />
400mm max. centres<br />
SECOND LAYER<br />
THIRD LAYER<br />
LOCATION<br />
Centre of the Board<br />
Recessed Edges<br />
Corners & Openings<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints on studs<br />
Centre of the Board<br />
Recessed Edges<br />
Corners & Openings<br />
Butt Joints<br />
SCREW FIXINGS FOR SOFT WOOD TIMBER FRAMING<br />
FRAMING<br />
Soft Wood Timber<br />
FIREBOARD THICKNESS<br />
13mm<br />
16mm<br />
SCREW TYPE<br />
No 6 Type W<br />
No 6 Type W<br />
FIXING SPECIFICATIONS THREE LAYER<br />
VERTICAL-VERTICAL SHEETING (Shown)<br />
FIRST LAYER<br />
FASTENER SPACING<br />
600mm max. centres<br />
600mm max. centres<br />
600mm max. centres<br />
SECOND LAYER<br />
LOCATION<br />
Centre of the Board<br />
Recessed Edges<br />
Corners & Openings<br />
2 nails 50mm apart at<br />
300mm max. centre<br />
Centre of the Board<br />
1 scew at 300mm max.<br />
centres<br />
300mm max. centres Recessed Edges<br />
Laminating Screws<br />
200mm max. centres<br />
Butt Joints<br />
Nail screws 150mm max Corners & Openings<br />
300mm max. centres<br />
THIRD LAYER<br />
Laminating Screws at<br />
400mm max. grid<br />
Laminating Screws<br />
200mm max. centres<br />
1ST LAYER<br />
32mm<br />
45mm<br />
Centre of the Board<br />
Recessed Edges<br />
Corners & Openings<br />
SCREW LENGTH<br />
2ND LAYER<br />
50mm<br />
65mm<br />
Butt Joints<br />
3RD LAYER<br />
50mm<br />
65mm
FRL<br />
60 / 60 / 60<br />
FRL<br />
90 / 90 / 90<br />
FRL<br />
60 / 60 / 60<br />
TIMBER FRAME EXTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINS AT 1350mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 7.5mm Duratex TM<br />
Side 2<br />
STUD WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
1 x 10mm <strong>BGC</strong> Plasterboard<br />
<strong>Fire</strong> rated from outside only<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINS AT 1350mm MAX CENTRES<br />
Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 7.5mm Duratex TM<br />
Side 2<br />
STUD WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
1 x 10mm <strong>BGC</strong> Plasterboard<br />
<strong>Fire</strong> rated from outside only<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINS AT 1350mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 9mm Duragrid TM<br />
Side 2<br />
STUD WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
1 x 10mm <strong>BGC</strong> Plasterboard<br />
<strong>Fire</strong> rated from outside only<br />
Timber batten can be substituted for steel batten<br />
90<br />
41/35<br />
45/38<br />
45/38<br />
123.5<br />
90<br />
45/39<br />
48/42<br />
48/42<br />
123.5<br />
90<br />
38/27<br />
45/34<br />
45/34<br />
125<br />
120<br />
Rw/Rw+Ctr<br />
42/35<br />
46/40<br />
46/41<br />
123.5<br />
120<br />
Rw/Rw+Ctr<br />
45/39<br />
48/44<br />
48/45<br />
123.5<br />
120<br />
Rw/Rw+Ctr<br />
41/31<br />
47/37<br />
47/37<br />
155<br />
TE001<br />
140<br />
42/36<br />
46/41<br />
46/41<br />
123.5<br />
TE002<br />
140<br />
46/39<br />
48/45<br />
49/45<br />
123.5<br />
TE003<br />
140<br />
43/34<br />
48/39<br />
48/39<br />
175<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
06 / EXTERIOR WALL INFORMATION<br />
75
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 06 / EXTERIOR WALL INFORMATION<br />
76<br />
TIMBER FRAME EXTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
FRL<br />
90 / 90 / 90<br />
FRL<br />
60 / 60 / 60<br />
FRL<br />
90 / 90 / 90<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINS AT 1350mm MAX CENTRES<br />
Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 9mm Duragrid TM<br />
Side 2<br />
STUD WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
1 x 10mm <strong>BGC</strong> Plasterboard<br />
<strong>Fire</strong> rated from outside only<br />
Timber batten can be substituted for stee<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINS AT 1350mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 9mm Duracom TM<br />
Side 2<br />
STUD WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
1 x 10mm <strong>BGC</strong> Plasterboard<br />
<strong>Fire</strong> rated from outside only<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINS AT 1350mm MAX CENTRES<br />
Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 9mm Duracom TM<br />
Side 2<br />
STUD WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
1 x 10mm <strong>BGC</strong> Plasterboard<br />
<strong>Fire</strong> rated from outside only<br />
90<br />
42/30<br />
48/37<br />
48/37<br />
141<br />
90<br />
40/28<br />
46/34<br />
46/34<br />
125<br />
90<br />
40/28<br />
49/34<br />
49/34<br />
141<br />
120<br />
Rw/Rw+Ctr<br />
45/35<br />
50/40<br />
50/40<br />
171<br />
120<br />
Rw/Rw+Ctr<br />
43/32<br />
48/37<br />
48/37<br />
155<br />
120<br />
Rw/Rw+Ctr<br />
44/32<br />
50/37<br />
50/37<br />
171<br />
TE004<br />
140<br />
47/37<br />
51/41<br />
51/41<br />
191<br />
TE005<br />
140<br />
44/34<br />
48/38<br />
48/38<br />
175<br />
TE006<br />
140<br />
45/34<br />
51/39<br />
51/39<br />
191
FRL<br />
60 / 60 / 60<br />
FRL<br />
90 / 90 / 90<br />
FRL<br />
60 / 60 / 60<br />
TIMBER FRAME EXTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINS AT 1350mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 14mm Nuline TM Plus<br />
Side 2<br />
STUD WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
1 x 10mm <strong>BGC</strong> Plasterboard<br />
<strong>Fire</strong> rated from outside only<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINS AT 1350mm MAX CENTRES<br />
Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 14mm Nuline TM Plus<br />
Side 2<br />
STUD WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
1 x 10mm <strong>BGC</strong> Plasterboard<br />
<strong>Fire</strong> rated from outside only<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINS AT 1350mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 9mm Durascape TM<br />
Side 2<br />
STUD WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
1 x 10mm <strong>BGC</strong> Plasterboard<br />
<strong>Fire</strong> rated from outside only<br />
90<br />
41/30<br />
46/34<br />
46/34<br />
130<br />
90<br />
42/29<br />
48/34<br />
48/34<br />
146<br />
90<br />
42/36<br />
46/39<br />
46/40<br />
125<br />
120<br />
Rw/Rw+Ctr<br />
41/31<br />
47/37<br />
47/37<br />
160<br />
120<br />
Rw/Rw+Ctr<br />
44/31<br />
50/37<br />
50/37<br />
176<br />
120<br />
Rw/Rw+Ctr<br />
43/36<br />
46/41<br />
46/41<br />
155<br />
TE007<br />
140<br />
44/33<br />
48/38<br />
48/38<br />
180<br />
TE008<br />
140<br />
46/33<br />
50/38<br />
50/38<br />
196<br />
TE009<br />
140<br />
43/37<br />
46/41<br />
46/42<br />
175<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
06 / EXTERIOR WALL INFORMATION<br />
77
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 06 / EXTERIOR WALL INFORMATION<br />
78<br />
TIMBER FRAME EXTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
FRL<br />
90 / 90 / 90<br />
FRL<br />
60 / 60 / 60<br />
FRL<br />
90 / 90 / 90<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINS AT 1350mm MAX CENTRES<br />
Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 9mm Durascape TM<br />
Side 2<br />
STUD WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
1 x 10mm <strong>BGC</strong> Plasterboard<br />
<strong>Fire</strong> rated from outside only<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINS AT 1350mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 9mm Duragroove TM<br />
Side 2<br />
STUD WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
1 x 10mm <strong>BGC</strong> Plasterboard<br />
<strong>Fire</strong> rated from outside only<br />
TIMBER STUDS AT 600mm MAX CENTRES<br />
WITH NOGGINS AT 1350mm MAX CENTRES<br />
Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 9mm Duragroove TM<br />
Side 2<br />
STUD WIDTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
1 x 10mm <strong>BGC</strong> Plasterboard<br />
<strong>Fire</strong> rated from outside only<br />
90<br />
45/39<br />
48/43<br />
48/43<br />
141<br />
90<br />
42/36<br />
46/39<br />
46/39<br />
128<br />
90<br />
45/39<br />
48/43<br />
48/43<br />
141<br />
120<br />
Rw/Rw+Ctr<br />
45/39<br />
49/44<br />
49/45<br />
171<br />
120<br />
Rw/Rw+Ctr<br />
43/36<br />
46/41<br />
46/41<br />
155<br />
120<br />
Rw/Rw+Ctr<br />
45/39<br />
49/44<br />
49/45<br />
171<br />
TE010<br />
140<br />
46/40<br />
49/44<br />
49/45<br />
191<br />
TE011<br />
140<br />
43/37<br />
46/41<br />
46/42<br />
175<br />
TE012<br />
140<br />
46/40<br />
49/44<br />
49/44<br />
191
FRL<br />
60 / 60 / 60<br />
FRL<br />
90 / 90 / 90<br />
FRL<br />
60 / 60 / 60<br />
STEEL FRAME EXTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 7.5mm Duratex TM<br />
Side 2<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 7.5mm Duratex TM<br />
Side 2<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
<strong>Fire</strong> rated from outside only<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 9mm Duragrid TM<br />
Side 2<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
<strong>Fire</strong> rated from outside only<br />
64<br />
42/36<br />
49/41<br />
50/41<br />
103.5<br />
64<br />
48/41<br />
56/50<br />
57/50<br />
135.5<br />
Timber batten can be substituted for steel<br />
64<br />
42/30<br />
49/37<br />
49/37<br />
105<br />
76 92<br />
Rw/Rw+Ctr<br />
42/35<br />
50/43<br />
51/43<br />
115.5<br />
76<br />
48/41<br />
57/51<br />
57/51<br />
147.5<br />
76<br />
44/33<br />
51/40<br />
51/40<br />
117<br />
43/36<br />
51/44<br />
51/44<br />
131.5<br />
92<br />
Rw/Rw+Ctr<br />
49/42<br />
57/51<br />
57/51<br />
163.5<br />
92<br />
Rw/Rw+Ctr<br />
46/36<br />
52/42<br />
52/42<br />
133<br />
SE001<br />
150<br />
45/37<br />
52/47<br />
52/47<br />
189.5<br />
SE002<br />
150<br />
52/44<br />
57/52<br />
57/52<br />
221.5<br />
SE003<br />
150<br />
50/42<br />
55/46<br />
55/46<br />
191<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
06 / EXTERIOR WALL INFORMATION<br />
79
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 06 / EXTERIOR WALL INFORMATION<br />
80<br />
STEEL FRAME EXTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
FRL<br />
90 / 90 / 90<br />
FRL<br />
60 / 60 / 60<br />
FRL<br />
90 / 90 / 90<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 9mm Duragrid TM<br />
Side 2<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
<strong>Fire</strong> rated from outside only<br />
Timber batten can be substituted for steel<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 9mm Duracom TM<br />
Side 2<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
<strong>Fire</strong> rated from outside only<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 9mm Duracom TM<br />
Side 2<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
<strong>Fire</strong> rated from outside only<br />
64<br />
50/40<br />
57/46<br />
57/46<br />
137<br />
64<br />
44/33<br />
49/37<br />
50/38<br />
105<br />
64<br />
51/41<br />
57/45<br />
57/45<br />
137<br />
76 92<br />
Rw/Rw+Ctr<br />
51/42<br />
58/48<br />
58/48<br />
149<br />
76<br />
45/35<br />
52/40<br />
52/40<br />
117<br />
76<br />
53/42<br />
58/46<br />
58/46<br />
149<br />
52/43<br />
59/49<br />
59/49<br />
165<br />
92<br />
Rw/Rw+Ctr<br />
47/37<br />
53/42<br />
53/42<br />
133<br />
92<br />
Rw/Rw+Ctr<br />
54/44<br />
59/48<br />
59/48<br />
165<br />
SE004<br />
150<br />
54/46<br />
60/53<br />
60/53<br />
223<br />
SE005<br />
150<br />
52/42<br />
56/46<br />
56/46<br />
191<br />
SE006<br />
150<br />
56/46<br />
59/51<br />
59/51<br />
223
FRL<br />
60 / 60 / 60<br />
FRL<br />
90 / 90 / 90<br />
FRL<br />
60 / 60 / 60<br />
STEEL FRAME EXTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 14mm Nuline TM Plus<br />
Side 2<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
<strong>Fire</strong> rated from outside only<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 14mm Nuline TM Plus<br />
Side 2<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
<strong>Fire</strong> rated from outside only<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 9mm Durascape TM<br />
Side 2<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
<strong>Fire</strong> rated from outside only<br />
64<br />
45/35<br />
50/38<br />
50/38<br />
110<br />
64<br />
52/40<br />
57/44<br />
57/44<br />
142<br />
64<br />
42/36<br />
50/42<br />
50/42<br />
105<br />
76 92<br />
Rw/Rw+Ctr<br />
47/36<br />
51/40<br />
51/40<br />
122<br />
76<br />
51/39<br />
58/45<br />
58/44<br />
154<br />
76<br />
42/36<br />
51/44<br />
51/44<br />
117<br />
46/36<br />
52/41<br />
52/41<br />
138<br />
92<br />
Rw/Rw+Ctr<br />
53/41<br />
58/46<br />
58/46<br />
170<br />
92<br />
Rw/Rw+Ctr<br />
43/36<br />
52/44<br />
52/45<br />
133<br />
SE007<br />
150<br />
50/40<br />
54/45<br />
54/45<br />
196<br />
SE008<br />
150<br />
56/45<br />
59/50<br />
59/50<br />
228<br />
SE009<br />
150<br />
45/38<br />
53/47<br />
53/48<br />
191<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
06 / EXTERIOR WALL INFORMATION<br />
81
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 06 / EXTERIOR WALL INFORMATION<br />
82<br />
STEEL FRAME EXTERIOR WALL SYSTEM<br />
SINGLE STUD<br />
FRL<br />
90 / 90 / 90<br />
FRL<br />
60 / 60 / 60<br />
FRL<br />
90 / 90 / 90<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 9mm Durascape TM<br />
Side 2<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
<strong>Fire</strong> rated from outside only<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 1 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 9mm Duragroove TM<br />
Side 2<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
<strong>Fire</strong> rated from outside only<br />
STEEL STUDS AT 600mm MAX CENTRES<br />
Side 1 2 x 16mm <strong>BGC</strong> Wet Area <strong>Fire</strong>board<br />
1 x 9mm Duragroove TM<br />
Side 2<br />
STUD DEPTH mm<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
WALL THICKNESS mm<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
<strong>Fire</strong> rated from outside only<br />
64<br />
48/41<br />
57/50<br />
57/51<br />
137<br />
64<br />
42/36<br />
50/42<br />
50/42<br />
105<br />
64<br />
48/41<br />
57/50<br />
57/51<br />
137<br />
76 92<br />
Rw/Rw+Ctr<br />
49/42<br />
57/51<br />
57/51<br />
149<br />
76<br />
42/36<br />
51/44<br />
51/44<br />
117<br />
76<br />
49/42<br />
57/51<br />
57/51<br />
149<br />
50/43<br />
57/51<br />
58/52<br />
165<br />
92<br />
Rw/Rw+Ctr<br />
43/36<br />
52/44<br />
52/45<br />
133<br />
92<br />
Rw/Rw+Ctr<br />
50/43<br />
57/51<br />
58/52<br />
165<br />
SE010<br />
150<br />
52/44<br />
58/53<br />
58/53<br />
223<br />
SE011<br />
150<br />
45/38<br />
53/47<br />
53/48<br />
191<br />
SE012<br />
150<br />
52/44<br />
58/53<br />
58/53<br />
223
TIMBER FRAME WITH ONE LAYER <strong>BGC</strong> WET AREA FIREBOARD<br />
60/60/60 BOUNDARY WALL<br />
SCREW FIXINGS FOR SOFT WOOD TIMBER FRAMING<br />
FRAMING<br />
Soft Wood Timber<br />
FIREBOARD THICKNESS<br />
16mm<br />
TIMBER FRAME WITH TWO LAYERS <strong>BGC</strong> WET AREA FIREBOARD<br />
90/90/90 BOUNDARY WALL<br />
INSTALLATION DETAILS<br />
EXTERIOR WALLS<br />
FASTENER SPACING<br />
2 Nails at 300mm max<br />
centres 1 screw at<br />
200mm max centres<br />
At each stud<br />
Nails at 150mm max<br />
centres screws at<br />
200mm max centres<br />
Nails at 150mm max<br />
centres screws at<br />
200mm max centres<br />
SCREW TYPE<br />
No 6 Type W<br />
SCREW FIXINGS FOR SOFT WOOD TIMBER FRAMING<br />
FRAMING<br />
Soft Wood Timber<br />
FIREBOARD THICKNESS<br />
16mm<br />
FIXING SPECIFICATIONS<br />
FIRST LAYER<br />
FASTENER SPACING<br />
Nails or Screws<br />
600mm max. centres<br />
Nails or Screws<br />
600mm max. centres<br />
Nails or Screws<br />
600mm max. centres<br />
in stagered pattern<br />
2 Nails 50mm apart at<br />
300mm max. centres<br />
1 screw at 200mm<br />
max. centres<br />
At Each Stud<br />
Nails at 150mm max.<br />
centres Screws at<br />
200mm max. centres<br />
Nails at 150mm<br />
max. centres Screws<br />
at 300mm max.<br />
centres<br />
SCREW TYPE<br />
No 6 Type W<br />
FIXING SPECIFICATIONS<br />
SECOND LAYER<br />
LOCATION<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints<br />
Corners & Openings<br />
SCREW LENGTH<br />
1ST LAYER<br />
45mm<br />
LOCATION<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints<br />
Corners & Openings<br />
SCREW LENGTH<br />
1ST LAYER<br />
45mm<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
06 / EXTERIOR WALL INFORMATION<br />
83
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 06 / EXTERIOR WALL INFORMATION<br />
84<br />
INSTALLATION DETAILS<br />
EXTERIOR WALLS<br />
STEEL FRAME WITH ONE LAYER <strong>BGC</strong> WET AREA FIREBOARD<br />
60/60/60 BOUNDARY WALL<br />
STEEL FRAME WITH TWO LAYERS <strong>BGC</strong> WET AREA FIREBOARD<br />
90/90/90 BOUNDARY WALL<br />
FIXING SPECIFICATIONS<br />
FASTENER SPACING<br />
300mm max. centres<br />
At Each Stud<br />
100mm max. centres<br />
300mm max.centres<br />
SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING<br />
FRAMING<br />
Lightweight Steel up to<br />
0.8mm<br />
Lightweight Steel 0.8mm<br />
to 1.6mm<br />
FIREBOARD THICKNESS<br />
16mm<br />
16mm<br />
SCREW TYPE<br />
No 6 Type S Needle Point<br />
No 6 Type D Drill Point<br />
FASTENER SPACING<br />
600mm max. centres<br />
600mm max. centres<br />
600mm max. centres<br />
300mm max. centres<br />
At Each Stud<br />
200mm max. centres<br />
300mm max.centres<br />
SCREW FIXINGS FOR LIGHTWEIGHT STEEL FRAMING<br />
FRAMING<br />
Lightweight Steel up to<br />
0.8mm<br />
Lightweight Steel 0.8mm<br />
to 1.6mm<br />
FIREBOARD THICKNESS<br />
16mm<br />
16mm<br />
SCREW TYPE<br />
No 6 Type S Needle Point<br />
No 6 Type D Drill Point<br />
LOCATION<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints<br />
Corners & Openings<br />
FIXING SPECIFICATIONS<br />
FIRST LAYER<br />
SECOND LAYER<br />
SCREW LENGTH<br />
1ST LAYER<br />
30mm<br />
32mm<br />
LOCATION<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints<br />
Centre of the Board<br />
Recessed Edges<br />
Butt Joints<br />
Corners & Openings<br />
SCREW LENGTH<br />
1ST LAYER 2ND LAYER<br />
30mm 45mm<br />
32mm<br />
45mm
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FLOOR / CEILING<br />
TIMBER OR STEEL JOISTS<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
MIN CAVITY DEPTH OF 190mm<br />
Ceiling Lining 1 x 13mm <strong>BGC</strong> Plasterboard<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
MIN CAVITY DEPTH OF 190mm<br />
Ceiling Lining 2 x 13mm <strong>BGC</strong> Plasterboard<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
MIN CAVITY DEPTH OF 190mm<br />
Ceiling Lining 1 x 10mm <strong>BGC</strong> Ceilingboard<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
39/33<br />
40/36<br />
40/36<br />
Rw/Rw+Ctr<br />
41/35<br />
42/39<br />
42/39<br />
Rw/Rw+Ctr<br />
37/31<br />
39/35<br />
39/35<br />
C001<br />
C002<br />
C003<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
07 / CEILING INFORMATION<br />
85
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 07 / CEILING INFORMATION<br />
86<br />
FLOOR / CEILING<br />
TIMBER OR STEEL JOISTS<br />
FRL<br />
- / - / -<br />
FRL<br />
90 / 90 / 90<br />
FRL<br />
30 / 30 / 30<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
MIN CAVITY DEPTH OF 190mm<br />
Ceiling Lining 2 x 10mm <strong>BGC</strong> Soundboard TM<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
41/36<br />
42/39<br />
42/39<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
MIN CAVITY DEPTH OF 190mm<br />
Ceiling Lining 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Rw/Rw+Ctr<br />
43/38<br />
44/41<br />
44/41<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
MIN CAVITY DEPTH OF 190mm<br />
Ceiling Lining 1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
40/35<br />
40/38<br />
40/38<br />
C004<br />
C005<br />
C018
FRL<br />
90 / 90 / 90<br />
FRL<br />
120 / 120 / 120<br />
FLOOR / CEILING<br />
TIMBER OR STEEL JOISTS<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
MIN CAVITY DEPTH OF 190mm<br />
Ceiling Lining 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
MIN CAVITY DEPTH OF 190mm<br />
Ceiling Lining 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
43/38<br />
44/41<br />
44/41<br />
Rw/Rw+Ctr<br />
45/40<br />
46/44<br />
46/44<br />
C006<br />
C007<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
07 / CEILING INFORMATION<br />
87
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 07 / CEILING INFORMATION<br />
88<br />
FLOOR / CEILING<br />
TIMBER OR STEEL JOISTS WITH FURRING CHANNELS TIMBER OR STEEL<br />
JOISTS WITH FURRING CHANNELS<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
WITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm<br />
Ceiling Lining 1 x 10mm <strong>BGC</strong> Ceilingboard<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
39/33<br />
42/38<br />
42/38<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
WITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm<br />
Ceiling Lining 1 x 13mm <strong>BGC</strong> Plasterboard<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
40/34<br />
43/39<br />
43/39<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
WITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm<br />
Ceiling Lining 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
(furring channel at 450mm max centres)<br />
Rw/Rw+Ctr<br />
40/33<br />
43/39<br />
43/39<br />
C010<br />
C011<br />
C012
FRL<br />
- / - / -<br />
FRL<br />
60 / 60 / 60<br />
FRL<br />
90 / 90 / 90<br />
FLOOR / CEILING<br />
TIMBER OR STEEL JOISTS WITH FURRING CHANNELS<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
WITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm<br />
Ceiling Lining 1 x 9mm <strong>BGC</strong> Duraliner TM<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
43/37<br />
45/41<br />
45/41<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
WITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm<br />
Ceiling Lining 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
43/38<br />
46/43<br />
46/43<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
WITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm<br />
Ceiling Lining 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
Rw/Rw+Ctr<br />
44/39<br />
47/44<br />
47/44<br />
C013<br />
C014<br />
C015<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
07 / CEILING INFORMATION<br />
89
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 07 / CEILING INFORMATION<br />
90<br />
FLOOR / CEILING<br />
TIMBER OR STEEL JOISTS WITH FURRING CHANNELS<br />
FRL<br />
90 / 90 / 90<br />
FRL<br />
120 / 120 / 120<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
WITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm<br />
Ceiling Lining 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
44/39<br />
47/44<br />
47/44<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
WITH FURRING CHANNELS MIN CAVITY DEPTH OF 206mm<br />
Ceiling Lining 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
46/41<br />
49/47<br />
49/47<br />
C016<br />
C017
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FLOOR / CEILING<br />
TIMBER OR STEEL JOISTS WITH FURRING CHANNELS<br />
AND ACOUSTIC RESILIENT MOUNTS<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />
MIN CAVITY DEPTH OF 232mm<br />
Ceiling Lining 1 x 13mm <strong>BGC</strong> Plasterboard<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />
MIN CAVITY DEPTH OF 232mm<br />
Ceiling Lining 1 x 10mm <strong>BGC</strong> Soundboard TM<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />
MIN CAVITY DEPTH OF 232mm<br />
Ceiling Lining 2 x 10mm <strong>BGC</strong> Soundboard TM<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
42/34<br />
49/42<br />
50/43<br />
Rw/Rw+Ctr<br />
42/34<br />
49/42<br />
50/43<br />
Rw/Rw+Ctr<br />
47/38<br />
54/48<br />
55/49<br />
C020<br />
C021<br />
C022<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
07 / CEILING INFORMATION<br />
91
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 07 / CEILING INFORMATION<br />
92<br />
FLOOR / CEILING<br />
TIMBER OR STEEL JOISTS WITH FURRING CHANNELS<br />
AND ACOUSTIC RESILIENT MOUNTS<br />
FRL<br />
90 / 90 / 90<br />
FRL<br />
60 / 60 / 60<br />
FRL<br />
90 / 90 / 90<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />
MIN CAVITY DEPTH OF 232mm<br />
Ceiling Lining 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />
MIN CAVITY DEPTH OF 232mm<br />
Ceiling Lining 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
19mm TONGUE & GROOVE PARTICLEBOARD FLOORING<br />
WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />
MIN CAVITY DEPTH OF 232mm<br />
Ceiling Lining 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
48/39<br />
55/49<br />
56/50<br />
Rw/Rw+Ctr<br />
48/39<br />
55/49<br />
56/50<br />
Rw/Rw+Ctr<br />
49/41<br />
56/49<br />
56/50<br />
C023<br />
C024<br />
C025
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
ROOF / CEILING<br />
TIMBER TRUSSES<br />
PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />
OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />
BATTENS MAX JOIST OR TRUSS SPACING AT 600mm<br />
Ceiling Lining 1 x 10mm <strong>BGC</strong> Soundboard TM<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />
OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />
BATTENS MAX JOIST OR TRUSS SPACING AT 600mm<br />
Ceiling Lining 2 x 10mm <strong>BGC</strong> Soundboard TM<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />
OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />
BATTENS MAX JOIST OR TRUSS SPACING AT 600mm<br />
Ceiling Lining 1 x 13mm <strong>BGC</strong> Plasterboard<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
-<br />
41/32<br />
42/32<br />
Rw/Rw+Ctr<br />
-<br />
45/36<br />
45/37<br />
Rw/Rw+Ctr<br />
-<br />
41/32<br />
42/32<br />
C030<br />
C031<br />
C032<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
07 / CEILING INFORMATION<br />
93
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 07 / CEILING INFORMATION<br />
94<br />
ROOF / CEILING<br />
TIMBER TRUSSES<br />
FRL<br />
- / - / -<br />
FRL<br />
60 / 60 / 60<br />
FRL<br />
90 / 90 / 90<br />
PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />
OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />
BATTENS MAX JOIST OR TRUSS SPACING AT 600mm<br />
Ceiling Lining 1 x 13mm <strong>BGC</strong> Soundboard TM<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
-<br />
42/34<br />
43/34<br />
PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />
OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />
BATTENS MAX JOIST OR TRUSS SPACING AT 600mm<br />
Ceiling Lining 2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
-<br />
45/37<br />
46/38<br />
PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />
OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />
BATTENS MAX JOIST OR TRUSS SPACING AT 600mm<br />
Ceiling Lining 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
-<br />
46/38<br />
47/39<br />
C033<br />
C037<br />
C034
FRL<br />
90 / 90 / 90<br />
FRL<br />
120 / 120 / 120<br />
ROOF / CEILING<br />
TIMBER TRUSSES<br />
PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING OR<br />
SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS<br />
MAX JOIST OR TRUSS SPACING AT 600mm<br />
Ceiling Lining 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
-<br />
46/38<br />
46/38<br />
PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />
OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />
BATTENS MAX JOIST OR TRUSS SPACING AT 600mm<br />
Ceiling Lining 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
-<br />
48/41<br />
48/40<br />
C035<br />
C036<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
07 / CEILING INFORMATION<br />
95
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 07 / CEILING INFORMATION<br />
96<br />
ROOF / CEILING<br />
FURRING CHANNELS<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />
OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />
BATTENS WITH FURRING CHANNELS<br />
Ceiling Lining 1 x 10mm <strong>BGC</strong> Plasterboard<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
PITCHED TILED ROOF WITH OR WITHOUT350g/m 2 SARKING<br />
OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />
BATTENS WITH FURRING CHANNELS<br />
Ceiling Lining 1 x 10mm <strong>BGC</strong> Soundboard TM<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />
OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />
BATTENS WITH FURRING CHANNELS<br />
Ceiling Lining 1 x 13mm <strong>BGC</strong> Soundboard TM<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
-<br />
40/31<br />
40/31<br />
Rw/Rw+Ctr<br />
-<br />
43/34<br />
43/34<br />
Rw/Rw+Ctr<br />
-<br />
44/37<br />
44/36<br />
C040<br />
C041<br />
C042
FRL<br />
- / - / -<br />
FRL<br />
90 / 90 / 90<br />
FRL<br />
90 / 90 / 90<br />
ROOF / CEILING<br />
FURRING CHANNELS<br />
PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />
OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />
BATTENS WITH FURRING CHANNELS<br />
Ceiling Lining 1 x 6mm <strong>BGC</strong> Duraliner TM<br />
(Furring channels at 450 max centres)<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />
OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />
BATTENS WITH FURRING CHANNELS<br />
Ceiling Lining 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING<br />
OR SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER<br />
BATTENS WITH FURRING CHANNELS<br />
Ceiling Lining 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
-<br />
41/32<br />
41/32<br />
Rw/Rw+Ctr<br />
-<br />
48/41<br />
48/41<br />
Rw/Rw+Ctr<br />
-<br />
48/41<br />
48/41<br />
C043<br />
C044<br />
C045<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
07 / CEILING INFORMATION<br />
97
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 07 / CEILING INFORMATION<br />
98<br />
ROOF / CEILING<br />
FURRING CHANNELS<br />
FRL<br />
120 / 120 / 120<br />
PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING OR<br />
SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS<br />
WITH FURRING CHANNELS<br />
Ceiling Lining 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
-<br />
50/42<br />
51/43<br />
C046
FRL<br />
- / - / -<br />
FRL<br />
- / - / -<br />
FRL<br />
90 / 90 / 90<br />
ROOF / CEILING<br />
FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />
PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING OR<br />
SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS<br />
WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />
Ceiling Lining 1 x 10mm <strong>BGC</strong> Soundboard TM<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING OR<br />
SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS<br />
WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />
Ceiling Lining 2 x 10mm <strong>BGC</strong> Soundboard TM<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
PITCHED TILED ROOF WITH OR WITHOUT 350g/m 2 SARKING OR<br />
SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS<br />
WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />
Ceiling Lining 1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board (against frame)<br />
1 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
-<br />
44/35<br />
45/35<br />
Rw/Rw+Ctr<br />
-<br />
49/38<br />
50/39<br />
Rw/Rw+Ctr<br />
-<br />
50/40<br />
51/40<br />
C050<br />
C051<br />
C052<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
07 / CEILING INFORMATION<br />
99
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 07 / CEILING INFORMATION<br />
100<br />
ROOF / CEILING<br />
FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />
FRL<br />
90 / 90 / 90<br />
FRL<br />
120 / 120 / 120<br />
PITCHED TILED ROOF WITH OR WITHOUT 350g/m SARKING OR<br />
SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS<br />
WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />
Ceiling Lining 2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
PITCHED TILED ROOF WITH OR WITHOUT 350g/m SARKING OR<br />
SHEETMETAL ROOF WITH MIN 50mm INSULATION OVER BATTENS<br />
WITH FURRING CHANNELS AND ACOUSTIC RESILIENT MOUNTS<br />
Ceiling Lining 3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
CAVITY INFILL<br />
Nil<br />
9kg - 50mm Polyester<br />
30kg - 75mm Polyester<br />
Rw/Rw+Ctr<br />
-<br />
50/40<br />
52/41<br />
Rw/Rw+Ctr<br />
-<br />
53/43<br />
54/44<br />
C053<br />
C054
STEEL OR TIMBER WITH ONE OR TWO LAYERS OF <strong>BGC</strong> FIREBOARD –<br />
NAIL OR SCREW FIXING<br />
Note: Refer to page 10 for screw lengths.<br />
NOTE:<br />
One layer systems<br />
to be fixed as per<br />
2nd layer. Butt joints<br />
between framing are to<br />
be fully back blocked<br />
<strong>and</strong> fixed with<br />
laminating screws.<br />
INSTALLATION DETAILS<br />
CEILING<br />
FIXING SPECIFICATIONS ONE OR TWO<br />
LAYERS OF <strong>BGC</strong> FIREBOARD-<br />
NAIL OR SCREW FIXING<br />
FIRST LAYER<br />
FASTENER SPACING LOCATION<br />
Each framing member at<br />
10 to 16mm from sheet<br />
edges <strong>and</strong> at 200mm<br />
max centres<br />
150mm max centres<br />
150mm max centres<br />
Cornice finish - 200mm<br />
max centres. Set finish -<br />
150mm max centres<br />
Framing at 450mm -<br />
150mm max centres<br />
Framing at 600mm -<br />
within 50mm of centre<br />
line between framing<br />
& fix to ist layer with<br />
laminating screws at<br />
200mm max centres<br />
150mm max centres<br />
Cornice finish - 200mm<br />
max centres. Set finish -<br />
150mm max centres<br />
SECOND LAYER<br />
Centre of the Board<br />
Butt Joints<br />
Openings<br />
Sheet ends<br />
Butt Joints<br />
Openings<br />
Sheet ends<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
07 / CEILING INFORMATION<br />
101
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 07 / CEILING INFORMATION<br />
102<br />
INSTALLATION DETAILS<br />
CEILING<br />
STEEL OR TIMBER WITH THREE LAYERS OF <strong>BGC</strong> FIREBOARD –<br />
NAIL OR SCREW FIXING<br />
FIXING SPECIFICATIONS THREE OF<br />
<strong>BGC</strong> FIREBOARD - NAIL OR SCREW FIXING<br />
FIRST LAYER<br />
FASTENER SPACING<br />
LOCATION<br />
150mm max centres<br />
150mm max centres<br />
Cornice finish -<br />
200mm max centres<br />
Set finish - 150mm<br />
max centres<br />
Each framing member<br />
at 10 to 16mm from sheet<br />
edges <strong>and</strong> at 200mm<br />
max centres<br />
150mm max centres<br />
150mm max centres<br />
Cornice finish -<br />
200mm max centres<br />
Set finish - 150mm<br />
max centres<br />
Each framing member at<br />
10 to 16mm from sheet<br />
edges <strong>and</strong> at 200mm<br />
max centres<br />
Within 50mm of centre<br />
line between framing &<br />
fix to previous layer with<br />
laminating screws at<br />
200mm max centres<br />
150mm max centres<br />
Cornice finish - 200mm<br />
max centres. Set finish -<br />
150mm max centres<br />
SECOND LAYER<br />
THIRD LAYER<br />
Centre of the Board<br />
Butt Joints<br />
Openings<br />
Sheet ends<br />
Centre of the Board<br />
Butt Joints<br />
Openings<br />
Sheet ends<br />
Centre of the Board<br />
Butt Joints<br />
Openings<br />
Sheet ends<br />
Note: Refer to page 10 for screw lengths.
STEEL OR TIMBER WITH ONE OR TWO LAYERS OF <strong>BGC</strong> FIREBOARD –<br />
NAIL OR SCREW FIXING<br />
• Steel angle fixed to the soffit or wall junction.<br />
• Universal Encasement Clips friction fitted<br />
to the remaining column/beam flanges.<br />
• Wall Furring Track is held in the back tongue of the clip.<br />
• Noggings at each end of the column/beam<br />
<strong>and</strong> behind plasterboard butt joins in<br />
single layer systems.<br />
FRL SYSTEM NO. LININGS<br />
30/-/-<br />
60/-/-<br />
90/-/-<br />
90/-/-<br />
120/-/-<br />
180/-/-<br />
CB01<br />
CB02<br />
CB03<br />
CB04<br />
CB05<br />
CB06<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
3 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
4 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
COLUMN OR BEAM<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
08 / COLUMNS / BEAMS / PENETRATIONS<br />
103
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
COLUMN OR BEAM<br />
STEEL OR TIMBER WITH ONE OR TWO LAYERS OF <strong>BGC</strong> FIREBOARD –<br />
NAIL OR SCREW FIXING<br />
FRL SYSTEM NO. LININGS<br />
08 / COLUMNS / BEAMS / PENETRATIONS 104<br />
30/-/-<br />
60/-/-<br />
90/-/-<br />
120/-/-<br />
180/-/-<br />
CB07<br />
CB08<br />
CB09<br />
CB10<br />
CB11<br />
1 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
2 x 13mm <strong>BGC</strong> <strong>Fire</strong>board<br />
2 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
3 x 16mm <strong>BGC</strong> <strong>Fire</strong>board<br />
4 x 16mm <strong>BGC</strong> <strong>Fire</strong>board
Special design considerations apply to<br />
<strong>Fire</strong> Rated walls in order to maintain the<br />
<strong>Fire</strong> Rating (FRL) of a system.<br />
• Electrical penetrations must not be placed<br />
back to back or more than one penetration<br />
per stud spacing.<br />
• Proprietary <strong>Fire</strong> Rated switch boxes are<br />
to be used.<br />
• <strong>BGC</strong> Plasterboard recommends the use of<br />
min R1.5 insulation batt be included in the<br />
wall cavity to assist in maintaining acoustic<br />
integrity.<br />
• All penetrations shall be sealed with an<br />
approved AS/NZS 1530.4 <strong>Fire</strong> Rated mastic<br />
filler. See Figure 1.<br />
• Where plumbing penetrations are required -<br />
all pipework must be self supporting.<br />
FIGURE 1<br />
Pipe Penetration Through Wall (copper)<br />
Backing rod<br />
(not fire rated)<br />
<strong>BGC</strong><br />
<strong>Fire</strong>board<br />
FIGURE 2<br />
Pipe Penetration Through Ceiling<br />
6mm<br />
Wire mesh<br />
flame guard<br />
n<br />
15mm Mi<br />
100mm Max<br />
(copper) pipe<br />
<strong>Fire</strong> rated mastic filler<br />
<strong>Fire</strong> rated<br />
mastic filler<br />
Pipewor<br />
(152mm<br />
max diam<br />
20mm<br />
I.B.S. Fyreguard<br />
foam 50 x 20<br />
<strong>BGC</strong> <strong>Fire</strong>board<br />
k<br />
)<br />
PENETRATIONS<br />
TYPICAL<br />
FIGURE 3<br />
Control Joint - Wall Frame Double Layer<br />
<strong>Fire</strong> rated mastic<br />
Min depth 15mm<br />
Rondo P53<br />
control joint<br />
typical<br />
FIGURE 4<br />
Control Joint - Wall Frame Single Layer<br />
<strong>Fire</strong> rated mastic<br />
Min depth 15mm<br />
Rondo P53<br />
control joint<br />
typical<br />
FIGURE 5<br />
Control Joint - Wall Frame<br />
<strong>Fire</strong> rated mastic<br />
Min depth 15mm<br />
FIGURE 6<br />
Electrical Penetration Through Wall (Typical)<br />
Note: Do not place switch boxes back to back.<br />
Proprietery fire<br />
rated switch box<br />
installed to<br />
manufacturers<br />
recommendations<br />
<strong>Fire</strong> rated mastic<br />
15 mm<br />
15 mm<br />
10 mm<br />
<strong>BGC</strong> Fibre Cement sheeting<br />
<strong>BGC</strong> <strong>Fire</strong>board<br />
Backing rod<br />
20 mm min<br />
Top <strong>and</strong><br />
bottom track is<br />
discontinuous<br />
Additional stud<br />
required at control joint<br />
<strong>BGC</strong> <strong>Fire</strong>board<br />
Backing rod<br />
Backing rod<br />
15 mm min<br />
Top <strong>and</strong><br />
bottom track is<br />
discontinuous<br />
Additional stud<br />
required at control joint<br />
<strong>BGC</strong> <strong>Fire</strong>board<br />
Top <strong>and</strong><br />
bottom track is<br />
discontinuous<br />
Additional stud<br />
required at control joint<br />
<strong>BGC</strong> <strong>Fire</strong>board<br />
<strong>Fire</strong> rated mastic<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
08 / COLUMNS / BEAMS / PENETRATIONS<br />
105
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013 08 / COLUMNS / BEAMS / PENETRATIONS<br />
106<br />
PENETRATIONS<br />
TYPICAL<br />
FIRE PENETRATIONS FOR SINGLE, DOUBLE & STAGGERED<br />
STUD WALLS - ELEVATION
WARRANTY<br />
We warrant that our products are free from defects caused by faulty<br />
manufacture or materials for a period of 15 years from the date of<br />
purchase. If you acquire any defective products, we will repair or<br />
replace them, supply equivalent replacement products or refund the<br />
purchase price within 30 days of receiving a valid claim subject to<br />
product inspection <strong>and</strong> confirmation of the existence of a defect by<br />
<strong>BGC</strong>. We will bear the cost of any such repair, replacement or refund.<br />
This warranty is given by:<br />
<strong>BGC</strong> Plasterboard Pty Ltd<br />
Ground Floor, 290 Bushmead Rd, Hazelmere, WA 6055<br />
Phone: (08) 9374 2900 Fax: (08) 9374 2901<br />
To claim under this warranty, you must provide proof of purchase as<br />
a consumer <strong>and</strong> make a written claim (including any costs of claiming)<br />
to us at the address specified above within 30 days after the defect was<br />
reasonably apparent, or if the defect was reasonably apparent prior to<br />
installation, the claim must be made prior to installation. You may not<br />
claim under this warranty for loss or damage caused by:<br />
• faulty or incorrect installation by non-<strong>BGC</strong> installers (<strong>BGC</strong>’s installation<br />
procedures are at www.bgc.com.au/plasterboard);<br />
• failure to comply with the Building Code of Australia or any applicable<br />
legislation, regulations approvals <strong>and</strong> st<strong>and</strong>ards;<br />
• products not made or supplied by <strong>BGC</strong>;<br />
• abnormal use of the product; or<br />
• normal wear <strong>and</strong> tear.<br />
The benefits available under this warranty are in addition to other rights<br />
<strong>and</strong> remedies of the consumer under the law. Our goods come with<br />
guarantees that cannot be excluded under the Australian Consumer<br />
Law. You are entitled to a replacement or refund for a major failure <strong>and</strong><br />
for compensation for any other reasonably foreseeable loss or damage.<br />
You are also entitled to have the goods repaired or replaced if the goods<br />
fail to be of acceptable quality <strong>and</strong> the failure does not amount to a<br />
major failure.<br />
<strong>BGC</strong> FIRE & ACOUSTIC / MARCH 2013<br />
107
CONTACT<br />
ADELAIDE<br />
TELEPHONE<br />
08 8250 4962<br />
BRISBANE<br />
TELEPHONE<br />
07 2371 1711<br />
MELBOURNE<br />
TELEPHONE<br />
03 9392 9444<br />
PERTH<br />
TELEPHONE<br />
08 9334 4900<br />
SYDNEY<br />
TELEPHONE<br />
02 9771 9660<br />
NEW ZEALAND<br />
TELEPHONE<br />
0011 64 9264 1457<br />
Australian Owned & Manufactured<br />
www.bgc.com.au/plasterboard www.bgcinnovadesign.com.au