6. Rotate tightening plate and press it to bottom.<br />

Note: The tightening plate cannot be<br />

pressed to right position if the<br />

tightening sleeve is not rep<br />

sited completely.<br />

Tightening plate<br />

7. Connect with wiring terminal,<br />

install wire clamp and press<br />

the connecting wire tight.<br />

and the wiring connect on the terminal board,<br />

Wire clamp<br />

Connection terminal<br />

8. Install big handle<br />

Electric heating belt<br />

When outdoor ambient sensor malfunction happened,<br />

both of the electric heating belts stop working, otherwise,<br />

it will run at the following control:When Toutdoor ambient<br />

5 and the compressor doesn't started, that the<br />

compressor electric heating belt starts to work; Otherwise<br />

if compressor started or compressor doesn't start but<br />

Toutdoor ambient2 , the electric heating belt<br />

will not work. Compressor doesn't start and 5<br />

Toutdoor ambient 2compressor electric heating<br />

belt keeps the original state. When Toutdoor ambient<br />

3, the condenser electric heating belt work; Otherwise,<br />

if Toutdoor ambient6 , the condenser electric heating<br />

belt will not work. 3Toutdoor ambient6, the condenser<br />

electric heating belt will keep the original state.<br />

Electric heating belt<br />