Installation<br />

☆ Electric wiring<br />

1. Open the panel upwards;<br />

2. Disassemble the fixing bolts of wiring cover,<br />

as shown in right figure;<br />

3. Lead power connect cord though rear of<br />

button case from down to up;<br />

terminal, yellow-green wire (i.e. earth wire) onto "<br />

electric box.<br />

Power connect cord of<br />

indoor and outdoor unit<br />

4. Connect blue wire in power connect wire onto "N(1)" terminal, brown wire onto "2"<br />

" terminal (as shownin fig.3);<br />

and press the power connect cord by wire clamp that in front of line bank on<br />

5. To heat pump type unit, signal control cord connect with indoor unit through connector<br />

as (shown in fig.3), and tighten the control cord by clamp on bottom of case.<br />

6. Install the cover plate on its original and tighten screws.<br />

Wiring cover<br />

Line bank<br />

Brown<br />

Wire<br />

clamp<br />

Power connect cord<br />

Fig. 3<br />