Installation<br />
◆ Installation of Indoor <strong>Unit</strong><br />
☆• Install the Rear Panel<br />
1. Measure horizon by hanging line or<br />
horizontal measurement. Since drainage<br />
hole is at left side, it is better to adjust left<br />
side little lower.<br />
Fig. 1<br />
2. Fix rear panel on wall by bolts.<br />
3. Pull the panel by hand after installation to see if it is firm enough. The rear panel<br />
should be able to stand the weight of an adult (60kg). And the weight should be<br />
evenly shared each screw.<br />
☆ Install the Piping Hole<br />
1. After determined pipe hole location as fig.1, drill a hole (φ90) slant downward.<br />
2. In order to protect pipe and cable from damaging when going though wall, put on<br />
wall pipe.<br />
☆ Install the Drainage Hose<br />
1. For well draining, the drainage hose shoule be<br />
placed at a downward slant.<br />
Wrench<br />
Bend<br />
2. Do not wrench, bend or heave the drainage hose<br />
Don't flood it<br />
or flood its end in water.<br />
in water<br />
3. The prolonged drainage hose should be wrapped with insulation material<br />
when passing through indoor.<br />
☆ Install the Indoor <strong>Unit</strong><br />
1. Refer fig.a for piping mode of indoor unit. When piping (wiring) at left side, cut<br />
off tailings from pipe left from chassis of host (as shown in fig.4(b)).<br />
(1) Cut off tailing 1 when only power cord is led;<br />
(2) Cut off tailing 1 and 2 when connect pipe and wire are led;<br />
Piping mode 1 is recommended.<br />