Installation<br />

Wiring Collocation<br />

1. Power must adopt rated voltage and special circuit for air conditioner, diameter<br />

of the power cord should be big enough.<br />

2. Please don't pull power wire forcibly.<br />

3. Ear<strong>thin</strong>g should be reliable, and it should be connected on special ear<strong>thin</strong>g settings<br />

of the building. Do have them connected by professional personnel. Electric leakage<br />

protect switch and air switch with enough capacitance must be set in rated circuit<br />

(Refer to the following form). Air switch should includes magnetic and heat drop-out<br />

functions to ensure protect when curcuit short or overload occurs.<br />

Use Models<br />

Capacitance<br />

of air switch<br />

Min section<br />

of earth wire<br />

Min section<br />

of unit power cord<br />

GWHD09B2NK3AB<br />

10A<br />

1.0mm 2<br />

1.0mm 2<br />

GWHD12B2NK3AB<br />

15A<br />

1.5mm 2<br />

1.5mm 2<br />

Ear<strong>thin</strong>g Requirements<br />

1. Air conditioner is type I appliance, please do conduct reliable ear<strong>thin</strong>g measure.<br />

2. The yellow-green wire in the unit is earth wire, don't use it for other purpose or<br />

cut it. Don't fix it by self tapping screw, or electric shock may occur.<br />

3. Earth resistance should meet requirements on national standard GB17790.<br />

4.User power supply should offer reliable earth terminal. Don't connect earth wire to<br />

following places:<br />

1 Water pipe 2 Gas pipe 3 Drainage pipe 4 Other places where professional<br />

personnel considers unreliable.<br />

10