Installation<br />
Wiring Collocation<br />
1. Power must adopt rated voltage and special circuit for air conditioner, diameter<br />
of the power cord should be big enough.<br />
2. Please don't pull power wire forcibly.<br />
3. Ear<strong>thin</strong>g should be reliable, and it should be connected on special ear<strong>thin</strong>g settings<br />
of the building. Do have them connected by professional personnel. Electric leakage<br />
protect switch and air switch with enough capacitance must be set in rated circuit<br />
(Refer to the following form). Air switch should includes magnetic and heat drop-out<br />
functions to ensure protect when curcuit short or overload occurs.<br />
Use Models<br />
Capacitance<br />
of air switch<br />
Min section<br />
of earth wire<br />
Min section<br />
of unit power cord<br />
GWHD09B2NK3AB<br />
10A<br />
1.0mm 2<br />
1.0mm 2<br />
GWHD12B2NK3AB<br />
15A<br />
1.5mm 2<br />
1.5mm 2<br />
Ear<strong>thin</strong>g Requirements<br />
1. Air conditioner is type I appliance, please do conduct reliable ear<strong>thin</strong>g measure.<br />
2. The yellow-green wire in the unit is earth wire, don't use it for other purpose or<br />
cut it. Don't fix it by self tapping screw, or electric shock may occur.<br />
3. Earth resistance should meet requirements on national standard GB17790.<br />
4.User power supply should offer reliable earth terminal. Don't connect earth wire to<br />
following places:<br />
1 Water pipe 2 Gas pipe 3 Drainage pipe 4 Other places where professional<br />
personnel considers unreliable.<br />
10