<strong>LEONI</strong> is a global supplier of cabling systems and services for<br />
applications in the automotive business and other industries.<br />
In its new <strong>Infrastructure</strong> & <strong><strong>Data</strong>com</strong> business unit, <strong>LEONI</strong><br />
brings together the products and the expertise for power and<br />
communications networks in public buildings, in structural and<br />
civil engineering, in offices and in industry. Investors, integrators,<br />
planners, installers and businesses can thus obtain cables,<br />
connection technology and complete cabling solutions from<br />
a single source.<br />
The range includes system solutions based on copper and fiber<br />
optic technology as well as halogen-free power cables with and<br />
without functional endurance. Innovations in the areas of safety,<br />
environmental compatibility and energy efficiency offer enhanced<br />
customer benefits.<br />
Thanks to on-site consulting services and extensive experience,<br />
<strong>LEONI</strong> is an internationally recognised partner for your projects.<br />
You will find detailed information on our website at:<br />
www.leoni-infrastructure-datacom.com
www.leoni-infrastructure-datacom.com<br />
3<br />
VarioLine ® (For copper and fiber optic connection technology)<br />
VarioLine ® stands for data center system components, which can be used in both the copper and fiber optic connection<br />
range. The components in this catalogue are support frames for the copper modules MegaLineNet ® DClink and the fiber optic<br />
modules GigaLineNet ® DClink and GigaLineNet ® DC MTP ® /MPO module with the corresponding accessories as well as cable<br />
management panels controlled patch cord management.<br />
MegaLineNet ®<br />
(Copper connection technology)<br />
GigaLineNet ®<br />
(Fiber optic connection technology)<br />
MegaLineNet ® from <strong>LEONI</strong> is a copper system family for<br />
all transmission classes and categories that delivers a sound,<br />
future-proof investment. MegaLineNet ® incorporates the cable<br />
technology of the MegaLine ® patch and data cables as well<br />
as the MegaLineNet ® and VarioKeystone ® system solutions.<br />
MegaLineNet ® DC provides system components that are<br />
specifically designed to meet data center requirements.<br />
GigaLineNet ® is the name given to the range of fiber optic<br />
cable products that allow extremely high bandwidths and<br />
long transmission distances. The range is made up of the<br />
GigaLine ® fiber optic cables and the GigaLineNet ® system<br />
technology. The GigaLineNet ® DC system components are<br />
specifically adapted to data center requirements.<br />
4 Generic cabling in data centers<br />
6 Benefits<br />
7 Standards<br />
8 VarioLine ® – Copper and fiber optic connection range<br />
8 VarioLine ® – Consolidation points<br />
9 VarioLine ® – Cable management panels<br />
10 VarioLine ® – Frames and accessories<br />
12 MegaLineNet ® DC – Copper cabling systems<br />
13 MegaLineNet ® DClink – Links for data centers<br />
14 ParaLink ® – CX4 and InfiniBand ® patch cords<br />
16 MegaLineNet ® – Patch cords<br />
17 GigaLineNet ® DC – Fiber optic systems<br />
18 GigaLineNet ® DClink – Links for data centers<br />
21 GigaLineNet ® DCflex – Fiber optic connection technology<br />
22 GigaLineNet ® DCflex – Distributor housing<br />
23 GigaLineNet ® DCflex – Partial front panels/back panels<br />
24 GigaLineNet ® DCflex – Trunks<br />
25 GigaLineNet ® – MiniZip patch cords<br />
26 GigaLineNet ® – Uniboot patch cords<br />
27 GigaLineNet ® – Smart Box<br />
28 Structure of generic<br />
communications cabling<br />
30 Ordering information<br />
31 Services
4 Problems in data centers<br />
www.leoni-infrastructure-datacom.com<br />
Generic cabling in data centers<br />
Reducing costs<br />
Multi-cable solutions<br />
The heart of every business<br />
The data center is frequently referred to as the heart<br />
of a business, as it is from here that production and<br />
administration processes are controlled. Failures lead to<br />
catastrophic consequences that can threaten a company’s<br />
very survival. Availability must be guaranteed virtually<br />
24 hours a day, 365 days a year.<br />
Reliability is influenced to a major extent by the cabling.<br />
Single cables – laid-worn out-forgotten<br />
Not only is the laying of new cables difficult and time-consuming,<br />
but it is also virtually impossible to remove old cables, with<br />
the result that they often end up simply being cut out or left in<br />
place. This means that there is no possibility of reuse or recovery.<br />
An unobstructed flow of cooling air is out of the question in<br />
this case. Only a higher volumetric flow rate and/or a lower<br />
air temperature – both of which involve additional costs and<br />
environmental impact – can help here.<br />
Wide range of requirements<br />
Enormous energy requirements, greater environmental<br />
impact and rising energy prices are pushing ecological issues<br />
– along with conformity to standards – to the fore.<br />
The wide range of requirements to be met means that<br />
data centers must fulfil the following criteria:<br />
■■<br />
High availability (zero downtime) through maximum<br />
reliability<br />
■■<br />
Short installation times<br />
■■<br />
Outstanding performance<br />
■■<br />
Low space requirement – high packing density<br />
■■<br />
Cost efficiency<br />
■■<br />
Environmental compatibility – Green IT<br />
Reducing costs<br />
Requirements cannot be viewed in isolation. For example,<br />
ecological optimisation can lead to a reduction in costs, while<br />
expensive, industrially prefabricated components reduce<br />
installation and testing times and thus cut costs incurred<br />
as a result of downtime.<br />
Multi-cable – laid-used-reused<br />
Pre-assembled multi-cable solutions produce a clean, clear<br />
cabling layout, which not only contributes to simpler, faster<br />
cabling but also improves cooling air circulation. The cables and<br />
components used are also RoHS-compliant.<br />
A small number of multi-cables laid quickly and cleanly<br />
guarantee an unobstructed flow of cooling air.
VarioLine ® CP<br />
www.leoni-infrastructure-datacom.com<br />
<strong>Solutions</strong> for data centers<br />
5<br />
The solution<br />
Installation<br />
Fast – high-quality – cost-optimised<br />
<strong>LEONI</strong> has demonstrated forward thinking by developing products<br />
that go way beyond the current standards and requirements for<br />
data centers.<br />
The EC7 connector and corresponding cable reach a performance<br />
level beyond that of the F A<br />
class. Our fiber optic solutions<br />
guarantee systems with enormous attenuation and bandwidth<br />
reserves.<br />
Installation<br />
The link modules are simply inserted and clicked into place from<br />
the rear after the links are laid.<br />
As easy as 1-2-3<br />
This system can be used to create fiber optic, copper or mixed<br />
configurations in various categories. There is no need for<br />
on-site assembly. The modules can be removed using a basic<br />
extracting tool.<br />
The Plug and Play solution for copper and fiber optic applications<br />
from <strong>LEONI</strong> consists of pre-assembled links and the VarioLine ®<br />
DClink frame (19", 1 RU) for the DClink modules.<br />
GigaLineNet ® DClink<br />
MegaLineNet ® DClink<br />
GigaLineNet ® DCflex
6 Benefits for your data center<br />
www.leoni-infrastructure-datacom.com<br />
Benefits<br />
Reducing costs<br />
Optimising attenuation<br />
GigaLineNet ® DClink offers cost savings of up to 55% compared<br />
with conventional modular systems using MPO connection<br />
technology.<br />
A GigaLineNet ® DClink offers up to 70% less attenuation<br />
than conventional modular systems using MPO connection<br />
technology.<br />
Costs per link*<br />
100%<br />
Attenuation per link*<br />
I L<br />
=1.4 dB<br />
100%<br />
Modular solutions with MPO<br />
45%<br />
DClink<br />
Modular solutions with MPO<br />
I L<br />
=0.4 dB<br />
>30%<br />
DClink<br />
* Example: Link length: 30 m,<br />
fibers: 24xOS2e, connector: LC duplex<br />
* Example: Link length: 30 m,<br />
fibers: 24xOS2e, connector: LC duplex<br />
Minimising downtime<br />
Installation and commissioning take no time at all and there is<br />
no need for special tools or knowledge of assembly techniques.<br />
This reduces downtime to a minimum.<br />
High quality<br />
Product quality is factory-tested, with performance and safety<br />
built in.<br />
Ecologically sound cabling<br />
Environmentally sound materials and production methods, the<br />
possibility of recycling or ecologically viable recovery and, last<br />
but not least, the reusability of products if required guarantee<br />
maximum environmental compatibility.<br />
Cables and components from <strong>LEONI</strong> are RoHS-compliant.
www.leoni-infrastructure-datacom.com Standards 7<br />
Standards<br />
Standards<br />
The structure<br />
Generic communications cabling systems are defined in<br />
standards EN 50173-1 and ISO/IEC 11801. In addition, specific<br />
requirements for data centers are defined in EN 50173-5<br />
and ISO/IEC 24764.<br />
The cabling used in data centers consists of three<br />
subsystems:<br />
■■<br />
Network access cabling<br />
■■<br />
Main distribution cabling<br />
■■<br />
Zone distribution cabling<br />
Fiber types<br />
When using MM fibers, the requirements of class OF-300, using<br />
OM3 fibers, must be met as a minimum. Single-mode fibers<br />
must comply with category OS1 or OS2, whereby OS1 fibers<br />
do not meet the attenuation requirements in each case.<br />
The max. extension is 2,000 m. In data centers the main<br />
distribution cabling is frequently designed using fiber optic<br />
technology, while in smaller networks the external network<br />
interface (ENI) is connected directly to the zone distributor (ZD).<br />
The standards describe various models for flexible and fixed<br />
connections in and between the subsystems.<br />
The cabling of the main and zone distribution must, according<br />
to ISO/IEC 24764, meet the requirements of class E A<br />
for copper<br />
technology and transmission classes OF-300, OF-500 and<br />
OF-2000 for fiber optic technology as a minimum.<br />
Structure of the generic communications<br />
cabling system<br />
Standards-compliant connection technology in data<br />
centers<br />
Cu technology:<br />
RJ45, GG45 TM and Tera TM<br />
Fiber optic cable connectors: LC for 1 or 2 and MPO for more<br />
than 2 fibers, GG45 TM and Tera TM<br />
ENI<br />
Network<br />
access<br />
cabling<br />
MD ZD<br />
LDP EO EQP<br />
Main<br />
distribution<br />
cabling<br />
Zone distribution cabling<br />
Equipment<br />
cabling<br />
ENI:<br />
MD:<br />
ZD:<br />
LDP:<br />
EO:<br />
EQP:<br />
External network interface<br />
Main distributor<br />
Zone distributor<br />
Local distribution point (optional)<br />
External network interface<br />
Transmission equipment
8 VarioLine ® DC<br />
www.leoni-infrastructure-datacom.com<br />
VarioLine ® Consolidation points (CPs)<br />
VarioLine ® Consolidation points<br />
In office cabling (EN 50173-2), consolidation points (CPs)<br />
between floor distributor (FD) and telecommunication outlet<br />
(TO) offer extremely flexible solutions for rapidly changing office<br />
configurations. The CP can be installed in raised floors, inserted<br />
ceilings, columns or ducts. From there, flexible cables (CP cables)<br />
lead to the data outlets at the workplace.<br />
housings. The easy snap-in installation of the housing cover<br />
on the floor or zone distributor side makes troublesome screwing<br />
and the use of special tools unnecessary. The patch side is covered<br />
by a hinged cover with a strip bush as dust protection. The incoming<br />
cables and the CP/patch cords can be held by cable ties. The housing<br />
can be earthed if necessary.<br />
In data centers, CPs as local distribution points (LDP) can provide<br />
an additional patching option between zone distributor (ZD)<br />
and equipment outlet (EO) (EN 50173-5). The CPs are connected to<br />
the EO using flexible pre-assembled cables fitted with jacks and<br />
connectors, known as consolidation point cables.<br />
The CP cables pass through the raised floor via the necessary floor<br />
outlets which are installed in the base plate. VarioLine ® CP floor<br />
outlets can be closed flush with the floor when they are not required<br />
and are set upright to pass cables through. The cover then also<br />
protects the cables as they come out.<br />
The robust VarioLine ® CPs are made of zinc-plated sheet steel and<br />
are available in three sizes for 6, 12 and 24 channels. The modular<br />
structure ensures that most Cu and FO systems are suitable for<br />
universal use. Different module panels for the copper and FO<br />
connection systems from <strong>LEONI</strong> are available for VarioLine ® CP
www.leoni-infrastructure-datacom.com VarioLine ® DC 9<br />
Cable management panels VarioLine ® DC CMP<br />
VarioLine ® DC CMP1<br />
Cable management panel 19",<br />
1 RU with 82 mm metal clips<br />
VarioLine ® DC CMP2<br />
Cable management panel 19",<br />
1 RU with 115 mm metal clips<br />
VarioLine ® DC CMP3<br />
Cable management panel 19"<br />
1 RU with 78 mm plastic clips<br />
Product description:<br />
For the secure installation of FO and<br />
Cu patch cords in the distribution cabinet.<br />
Product description:<br />
For the secure installation of FO and<br />
Cu patch cords in the distribution cabinet.<br />
Product description:<br />
For the secure installation of FO and<br />
Cu patch cords in the distribution cabinet.<br />
■■<br />
■■<br />
■■<br />
■■<br />
Panel: sheet steel, powder-coated<br />
Colour: light grey RAL 7035 and<br />
black RAL 9005<br />
Clips: metal, 82 mm<br />
Dimensions (W x H x D):<br />
483 mm x 44 mm x 95 mm<br />
■■<br />
Panel: sheet steel, powder-coated<br />
■■<br />
Colour: light grey RAL 7035<br />
■■<br />
■■<br />
Clips: metal, 115 mm<br />
Dimensions (W x H x D):<br />
483 mm x 44 mm x 127 mm<br />
■■<br />
Panel: sheet steel, powder-coated<br />
■■<br />
Colour: light grey RAL 7035<br />
■■<br />
■■<br />
Clips: plastic, 78 mm<br />
Dimensions (W x H x D):<br />
483 mm x 44 mm x 90 mm<br />
Colour:<br />
Art. no.:<br />
Colour:<br />
Art. no.:<br />
Colour:<br />
Art. no.:<br />
black RAL 9005<br />
9ZE30050<br />
light grey RAL 7035<br />
9A610028<br />
light grey RAL 7035<br />
9A610020<br />
light grey RAL 7035<br />
9ZE10006<br />
Pcs. per packing unit: 1<br />
Pcs. per packing unit: 1<br />
Pcs. per packing unit: 1
10 VarioLine ® DC<br />
www.leoni-infrastructure-datacom.com<br />
Frames and accessories VarioLine ® DClink<br />
VarioLine ® DClink<br />
frame, 19", 1 RU<br />
VarioLine ® DClink<br />
dummy cover<br />
Product description:<br />
■■<br />
■■<br />
For the simple, fast and secure installation of pre-assembled link<br />
segments in data centers.<br />
Supports max. 3 link segments<br />
■■<br />
Can be equipped with: FLine<br />
®<br />
DClink and/or<br />
ELine ® DClink segments<br />
■■<br />
Housing: sheet steel, 2 mm, powder-coated<br />
■■<br />
Colour: light grey RAL 7035<br />
■■<br />
Dimensions (W x H x D):<br />
483 mm x 44 mm x 43 mm<br />
Product description:<br />
■■<br />
VarioLine<br />
®<br />
link dummy cover for closing a segment opening of<br />
■■<br />
a VarioLine ® link frame<br />
Housing: sheet steel<br />
■■<br />
Colour: light grey RAL 7035<br />
■■<br />
Dimensions: (W x H x D):<br />
133 mm x 42 mm x 39 mm<br />
Designation:<br />
Art. no.:<br />
Designation:<br />
Art. no.:<br />
VarioLine ® frame, 19", 1 RU<br />
9R000000<br />
VarioLine ® dummy cover<br />
9R000001<br />
Pcs. per packing unit: 8<br />
Pcs. per packing unit: 8
www.leoni-infrastructure-datacom.com VarioLine ® DC 11<br />
Accessories VarioLine ® DClink<br />
VarioLine ® DClink Support<br />
for two six-way jacks<br />
VarioLine ® DClink<br />
six-way jack dummy<br />
VarioLine ® DClink removing tool<br />
Product description:<br />
For mounting two six-way jacks in<br />
a VarioLine ® DClink frame<br />
Product description:<br />
Dummy for adding when using just one<br />
six-way jack in a DClink frame<br />
Product description:<br />
Removing tool tool for releasing link segments<br />
from VarioLine ® DClink frames<br />
■■<br />
Housing: sheet steel<br />
■■<br />
Colour: light grey RAL 7035<br />
■■<br />
Dimensions (W x H x D):<br />
133 mm x 42 mm x 45 mm<br />
■■<br />
■■<br />
Housing: sheet steel<br />
Dimensions (W x H x D):<br />
115 mm x 16 mm x 56 mm<br />
■■<br />
■■<br />
Material: stainless steel<br />
Dimensions (W x H x D):<br />
65 mm x 40 mm x 4 mm<br />
Colour:<br />
Art. no.:<br />
Material:<br />
Art. no.:<br />
Material:<br />
Art. no.:<br />
light grey RAL 7035<br />
9R000003<br />
Sheet steel<br />
9R000004<br />
Stainless steel<br />
9R000002<br />
Pcs. per packing unit: 1<br />
Pcs. per packing unit: 1<br />
Pcs. per packing unit: 2 (1 pair)
MegaLineNet ® DC<br />
(Copper connection technology)
www.leoni-infrastructure-datacom.com MegaLineNet ® DC 13<br />
MegaLineNet ® DClink<br />
MegaLineNet ® DClink “40/100 GigaBit Ethernet”<br />
with ELine 1200 ® EC7 six-way jacks<br />
MegaLineNet ® DCink 10 GigaBit Ethernet<br />
with ELine 500 ® plus RJ45 six-way jacks<br />
Product description:<br />
Fully pre-assembled link consisting of a high-quality multi-cable,<br />
with a high tensile strength ELine 1200 ® EC7 six-way jack<br />
connection at both ends.<br />
Product description:<br />
Fully pre-assembled link consisting of a high-quality multi-cable,<br />
with a high tensile strength ELine 500 ® plus RJ45 six-way jack<br />
connection at both ends.<br />
Field of application: in data centers and in structured in-house<br />
cabling systems to ISO/IEC 11801 and EN 50173 (2nd edition).<br />
Suitable for all applications in classes D to F A<br />
, multimedia (video,<br />
data etc.) >10 GbE to IEEE 802.3an, cable sharing, VoIP, PoE, PoE+.<br />
Field of application: in data centers and in structured in-house<br />
cabling systems to ISO/IEC 11801 and EN 50173 (2nd edition).<br />
Suitable for all applications in classes D to E A<br />
up to 10 GbE to IEEE<br />
802.3an, VoIP, PoE, PoE+.<br />
Cable:<br />
■■<br />
MegaLine<br />
®<br />
F10-115 S/F Multi 6x (4x2xAWG 23/1 PIMF),<br />
■■<br />
■■<br />
■■<br />
Cat. 7 A<br />
(7KS70186)*<br />
Tensile strength: 650 N<br />
Flame-retardant and halogen-free outer sheath<br />
Sheath diameter: approx. 23.6 mm<br />
Cable:<br />
■■<br />
MegaLine<br />
®<br />
F10-115 S/F Multi 6x (4x2xAWG 23/1 PIMF),<br />
■■<br />
■■<br />
■■<br />
Cat. 7 A<br />
(7KS70186)*<br />
Tensile strength: 650 N<br />
Flame-retardant and halogen-free outer sheath<br />
Sheath diameter: approx. 23.6 mm<br />
Link six-way jacks:<br />
■■<br />
■■<br />
Configuration: 6 ELine 1200<br />
®<br />
EC7 jacks<br />
For multimedia applications up to 1.5 GHz<br />
■■<br />
Better than Cat. 7A to ISO/IEC 11801, amendment 1/2<br />
■■<br />
■■<br />
and EN 50173, 2nd edition, amendment 1/2 (draft)<br />
Housing: sheet steel<br />
Dimensions (W x H x D):<br />
115 mm x 16 mm x 56 mm<br />
Link six-way jacks:<br />
■■<br />
Configuration: 6 ELine 500<br />
®<br />
plus RJ45 jacks<br />
■■<br />
Cat. 6A to ISO/IEC 11801, amendment 1/2 and EN 50173,<br />
■■<br />
■■<br />
2nd edition, amendment 1/2 (draft)<br />
Housing: sheet steel<br />
Dimensions (W x H x D):<br />
115 mm x 16 mm x 56 mm<br />
Packing unit:<br />
Art. no.:<br />
1 fully pre-assembled link 9R400xxx<br />
(xxx = Length in dm)<br />
Packing unit:<br />
Art. no.:<br />
1 fully pre-assembled link 9R500xxx<br />
(xxx = Length in dm)<br />
* Other multi-cable and flex-cable designs on request<br />
* Other multi-cable and flex-cable designs on request
14 MegaLineNet® DC<br />
www.leoni-infrastructure-datacom.com<br />
ParaLink ®<br />
High-speed connections<br />
<strong>LEONI</strong> ParaLink ® cables<br />
To meet the extensive requirements for fast point-to-point<br />
data transmission applications in modern data centers,<br />
<strong>LEONI</strong> offers fully pre-assembled high-speed cables that exceed<br />
the requirements of the IEEE 802.3-2005 Type 10GBase-CX4<br />
standard and of the IBTA (InfiniBand Trade Association) standard.<br />
Compared with conventional CX4 and InfiniBand ® cable solutions,<br />
<strong>LEONI</strong> patch chords offer improved electromagnetic compatibility,<br />
which is achieved using special dual screening. This technology<br />
ensures interference-free and complete data transmission across<br />
the entire transmission path, right up as far as the connector.<br />
Thanks to the use of high-quality <strong>LEONI</strong> ParaLink ® cables,<br />
the systems have typically low attenuation characteristics<br />
at transmission distances of up to 17 m (10GBase-CX4) and a data<br />
transmission rate of 10 Gb/s per channel.<br />
CX4 patch cords<br />
<strong>LEONI</strong> CX4 and InfiniBand ® patch cords are manufactured semiautomatically.<br />
Manual production has been reduced in order to<br />
achieve a high level of uniformity in the manufacturing process.<br />
EDS patch cords can be used in data centers for cabling switches,<br />
routers and servers in Storage Area Networks (SAN) or High<br />
Performance Computing (HPC), as well as in mobile phone<br />
base stations.
www.leoni-infrastructure-datacom.com MegaLineNet ® DC 15<br />
Patch cords ParaLink ®<br />
<strong>LEONI</strong> 10GBase-CX4 patch cord<br />
<strong>LEONI</strong> InfiniBand ® patch cord<br />
Product description:<br />
Fully pre-assembled link consisting of a high-quality ParaLink ®<br />
high-speed cable with parallel pairs (twinaxial), assembled with<br />
a CX4 connector at both ends. Integrated strain relief, min. 250 N,<br />
from the cable via the connector.<br />
Product description:<br />
Fully pre-assembled link consisting of a high-quality ParaLink ®<br />
high-speed cable with parallel pairs (twinaxial), assembled with<br />
a CX4 connector at both ends. Integrated strain relief, min. 250 N,<br />
from the cable via the connector.<br />
Field of application:<br />
In data centers for SAN or HPC and in mobile phone base stations.<br />
Cable:<br />
■■<br />
8-pair (4X) ParaLink<br />
®<br />
high density cable with <strong>LEONI</strong>ZELL ® dielectric,<br />
■■<br />
small outer diameter and small bending radii<br />
Flame-retardant PVC or halogen-free outer sheath<br />
■■<br />
Sheath diameter: 5.1 to 9.3 mm (for AWG 32–24)<br />
Length dependent on core cross section:<br />
■■<br />
0.5 m to 2 m: AWG 30<br />
■■<br />
3 m to 5 m: AWG 28<br />
■■<br />
6 m to 12 m: AWG 26<br />
■■<br />
13 m to 15 m: AWG 24<br />
CX4 connector:<br />
■■<br />
■■<br />
Housing: die-cast zinc, nickel-plated<br />
Dimensions (W x H x D):<br />
25 mm x 14.79 mm x 71.95 mm<br />
Field of application:<br />
In data centers for SAN or HPC and in mobile phone base stations.<br />
Single <strong>Data</strong> Rates (SDR up to 2.5 Gb/s per channel) and Double <strong>Data</strong><br />
Rates (DDR up to 5 Gb/s per channel).<br />
Cable:<br />
■■<br />
8-pair (4X) ParaLink<br />
®<br />
high density cable with <strong>LEONI</strong>ZELL ® dielectric,<br />
■■<br />
small outer diameter and small bending radii.<br />
Flame-retardant PVC or halogen-free outer sheath<br />
■■<br />
Sheath diameter: 5.1 to 9.3 mm (for AWG 32–24)<br />
Length dependent on core cross section:<br />
■■<br />
0.5 m to 3 m: AWG 30<br />
■■<br />
4 m to 5 m: AWG 28<br />
■■<br />
6 m to 8 m: AWG 26<br />
■■<br />
9 m to 12 m: AWG 24<br />
CX4 connector:<br />
■■<br />
■■<br />
Housing: die-cast zinc, nickel-plated<br />
Dimensions (W x H x D):<br />
25 mm x 14.79 mm x 71.95 mm<br />
Designation:<br />
Art. no.:<br />
InfiniBand ® patch cord:<br />
Art. no.:<br />
10GBase-CX4 patch cords<br />
9R8CXxxx<br />
For SDR transmission<br />
9R8SDxxx<br />
For DDR transmission<br />
9R8DDxxx<br />
xxx = Length in dm<br />
xxx = Length in dm<br />
Pcs. per packing unit: 1<br />
Pcs. per packing unit: 1
16 MegaLineNet® DC<br />
www.leoni-infrastructure-datacom.com<br />
Patch cords MegaLineNet ®<br />
ELine 1200 ® EC7 patch cord<br />
“40/100” GigaBit Ethernet<br />
ELine 1200 ® EC7 patch cord 10<br />
GigaBit Ethernet<br />
Patch cord RJ45/RJ45 500 MHz<br />
Fast/GigaBit Ethernet<br />
Product description:<br />
■■<br />
Pre-assembled with an EC7 connector<br />
at both ends<br />
■■<br />
Allocation: 1:1<br />
■■<br />
Anti-kink protecting sleeve colour: yellow<br />
Product description:<br />
■■<br />
Pre-assembled with an EC7 connector<br />
at both ends<br />
■■<br />
Allocation: 1:1<br />
■■<br />
Anti-kink protecting sleeve colour: yellow<br />
Product description:<br />
■■<br />
Pre-assembled with an RJ45 connector<br />
at both ends, shielded<br />
■■<br />
Allocation: 1:1<br />
■■<br />
Anti-kink protecting sleeve colour: red<br />
Field of application:<br />
IEEE 802.3; 10 BASE-T; 100BASE-T;<br />
1000BASE-T; 10GBASE-T compliant; IEEE<br />
802.5 16 MB; ISDN; FDDI; ATM, multimedia<br />
(video, data, voice), VoIP, PoE, PoE+.<br />
Field of application:<br />
IEEE 802.3; 10BASE-T; 100BASE-T;<br />
1000BASE-T; 10GBASE-T compliant; IEEE<br />
802.5 16 MB; ISDN; FDDI; ATM, multimedia<br />
(video, data, voice), VoIP, PoE, PoE+.<br />
Field of application:<br />
IEEE 802.3; 10BASE-T; 100BASE-T;<br />
1000BASE-T; 10GBASE-T compliant IEEE<br />
802.5 16 MB; ISDN; FDDI; ATM, VoIP, PoE.<br />
Cable used:<br />
MegaLine<br />
®<br />
F10-120 S/F flex<br />
■■<br />
■■<br />
■■<br />
■■<br />
4x2xAWG 26/7 PIMF Cat. 7 A<br />
Flame-retardant and halogen-free outer<br />
sheath<br />
Colour: grey<br />
Connector: ELine 1200<br />
®<br />
EC7<br />
Cable used:<br />
MegaLine<br />
®<br />
F6-90 S/F flex<br />
■■<br />
■■<br />
■■<br />
■■<br />
4x2xAWG 27/7 PIMF Cat. 7<br />
Flame-retardant and halogen-free outer<br />
sheath<br />
Colour: grey<br />
Connector: ELine<br />
®<br />
1200 ® EC7<br />
Cable used:<br />
■■<br />
■■<br />
■■<br />
■■<br />
MegaLine<br />
®<br />
F6-90 S/F flex<br />
4x2xAWG 27/7 PIMF Cat. 7<br />
Flame-retardant and halogen-free outer<br />
sheath<br />
Colour: grey<br />
RJ45 connector: Hirose TM21<br />
Art. no.:<br />
Length:<br />
Art. no.:<br />
Length:<br />
Art. no.:<br />
Length:<br />
9KEO1010<br />
1.0 m<br />
9KEC1010<br />
1.0 m<br />
9A020383<br />
1.0 m<br />
9KEO1020<br />
2.0 m<br />
9KEC1020<br />
2.0 m<br />
9A020385<br />
2.0 m<br />
9KEO1030<br />
3.0 m<br />
9KEC1030<br />
3.0 m<br />
9A020387<br />
3.0 m<br />
9KEO1050<br />
5.0 m<br />
9KEC1050<br />
5.0 m<br />
9A020389<br />
5.0 m<br />
Pcs. per packing unit: 1<br />
Other lengths on request<br />
Pcs. per packing unit: 1<br />
Other lengths on request<br />
Pcs. per packing unit: 1<br />
Other lengths on request
GigaLineNet ® DC<br />
(Fiber optic connection technology)<br />
Product composition<br />
GigaLineNet DC
18 GigaLineNet ® DC<br />
www.leoni-infrastructure-datacom.com<br />
GigaLineNet ® DClink<br />
GigaLineNet ® DClink OS2<br />
Product description:<br />
Fully pre-assembled link consisting of a high-quality universal<br />
cable, with a high tensile strength DClink module connection<br />
at both ends.<br />
GigaLineNet ® DClink OM4<br />
Product description:<br />
Fully pre-assembled fiber optic link consisting of a high-quality<br />
universal cable, with a high tensile strength DClink module<br />
connection at both ends.<br />
Field of application:<br />
In data centers and in structured in-house cabling systems to ISO/IEC<br />
11801 and EN 50173 (2nd edition). Suitable for all applications up to<br />
class OF-10000.<br />
Cable:<br />
■■<br />
GigaLine<br />
®<br />
DQ 100U OS2 KL-U-DQ(ZN)BH<br />
■■<br />
■■<br />
■■<br />
1x12 or 24 E9/125 0.36F3.5/0.22H18 (ITU G652.D)<br />
Tensile strength: 1750 N<br />
Flame-retardant and halogen-free outer sheath<br />
Sheath diameter: approx. 7 or 7.5 mm<br />
Link module:<br />
■■<br />
Housing: sheet steel<br />
■■<br />
Colour: light grey RAL 7035<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
Dimensions: 135 mm x 40 mm x 150 mm<br />
Equipped with max. 12 LC duplex, 6 SC duplex,<br />
12 SC simplex, 12 E2000 simplex.<br />
Insertion loss: typ. 0.2 dB<br />
Return loss: >40 dB (PC), >70 dB (APC)<br />
Field of application:<br />
In data centers and in structured in-house cabling systems to ISO/<br />
IEC 11801 and EN 50173 (2nd edition). Suitable for all applications in<br />
classes >OF-300 (FLine 550), (10 GBE), OF-500 (GBE/Fiber Channel)<br />
and OF-2000 (Fast Ethernet).<br />
Cable:<br />
■■<br />
GigaLine<br />
®<br />
DQ 500U OM4 KL-U-DQ(ZN)BH 1x12<br />
■■<br />
■■<br />
■■<br />
■■<br />
or 24 G50/125 2.5B3500 0.7F500 (IEC 60793-2 A1a.3)<br />
Laser bandwidth: 4700 MHz x km<br />
Tensile strength: 1750 N<br />
Flame-retardant and halogen-free outer sheath<br />
Sheath diameter: approx. 7 or 7.5 mm<br />
Link module:<br />
■■<br />
Housing: sheet steel<br />
■■<br />
Colour: light grey RAL 7035<br />
■■<br />
■■<br />
■■<br />
■■<br />
Dimensions: 135 mm x 40 mm x 150 mm<br />
Equipped with fiber optic cable connectors (see table)<br />
Insertion loss: typ. 0.2 dB<br />
Return loss: >35 dB<br />
Configuration:<br />
Art. no.:<br />
6 LC duplex PC – 6 LC duplex PC 9R201xxx<br />
6 LC duplex PC – 6 SC duplex PC 9R202xxx<br />
6 SC duplex PC – 6 SC duplex PC 9R203xxx<br />
12 LC duplex PC – 12 LC duplex PC 9R204xxx<br />
12 E2000 simplex PC – 12 E2000 simplex PC 9R205xxx<br />
6 LC duplex PC – 12 E2000 simplex PC 9R206xxx<br />
Configuration:<br />
Art. no.:<br />
6 LC duplex PC – 6 LC duplex PC 9R101xxx<br />
6 LC duplex PC – 6 SC duplex PC 9R102xxx<br />
6 SC duplex PC – 6 SC duplex PC 9R103xxx<br />
12 LC duplex PC – 12 LC duplex PC 9R104xxx<br />
12 E2000 simplex PC – 12 E2000 simplex PC 9R105xxx<br />
6 LC duplex PC – 12 E2000 simplex PC 9R106xxx<br />
Other configurations on request, xxx = Length between<br />
the link modules in m. Pcs. per packing unit: 1<br />
Other configurations on request, xxx = Length between<br />
the link modules in m. Pcs. per packing unit: 1
www.leoni-infrastructure-datacom.com GigaLineNet ® DC 19<br />
GigaLineNet ® DClink<br />
GigaLineNet ® DClink OM3<br />
Product description:<br />
Fully pre-assembled fiber optic link consisting of a high-quality<br />
universal cable, with a high tensile strength DClink module<br />
connection at both ends.<br />
Field of application:<br />
In data centers and in in-house cabling systems to ISO/IEC 11801<br />
and EN 50173 (2nd edition). Suitable for all applications in classes<br />
OF-300 (10 GBE), OF-500 (GBE/Fiber Channel) and OF-2000<br />
(Fast Ethernet).<br />
Cable:<br />
■■<br />
GigaLine<br />
®<br />
DQ 500U OM3 KL-U-DQ(ZN)BH 1x12 or 24 G50/125<br />
■■<br />
■■<br />
■■<br />
■■<br />
2.5B3500 0.7F500 (IEC 60793-2 A1a.2)<br />
Laser bandwidth: 2000 MHz x km<br />
Tensile strength: 1750 N<br />
Flame-retardant and halogen-free outer sheath<br />
Sheath diameter: approx. 7 or 7.5 mm<br />
Link module:<br />
■■<br />
Housing: sheet steel<br />
■■<br />
Colour: light grey RAL 7035<br />
■■<br />
■■<br />
■■<br />
■■<br />
Dimensions: 135 mm x 40 mm x 150 mm<br />
Equipped with fiber optic cable connectors (see table)<br />
Insertion loss: typ. 0.2 dB<br />
Return loss: >35 dB<br />
GigaLineNet ® DClink ® MTP ® /MPO module<br />
OS2, OM3, OM4<br />
Product description:<br />
Fully pre-assembled MTP ® /MPO module for installation in<br />
a DClink frame.<br />
Field of application:<br />
In data centers and in in-house cabling systems to ISO/IEC 11801<br />
and EN 50173 (2nd edition). Suitable for all applications in classes<br />
> OF-300 (FLine 550), (10 GBE), OF-500 (GBE/Fiber Channel) and<br />
OF-2000 (Fast Ethernet).<br />
DC module:<br />
Housing: sheet steel<br />
■■<br />
■■<br />
Colour: light grey RAL 7035<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
Dimensions: 135 mm x 40 mm x 150 mm<br />
Front equipped with max. 12 LC duplex, 6 SC duplex, 12 SC<br />
simplex, 12 E2000 simplex.<br />
Insertion loss: typ. 0.2 dB<br />
Return loss: >40 dB (SM, PC), >70 dB (SM, APC), >35 dB (MM)<br />
Rear equipped with 1x or 2x MTP® /MPO<br />
Insertion loss: typ. 0.3 dB<br />
Return loss: >55 dB (SM) >20 dB (MM)<br />
Fiber types: OS2, OM4, OM3<br />
Configuration:<br />
Art. no.:<br />
6 LC duplex PC - 6 LC duplex PC 9R301xxx<br />
6 LC duplex PC - 6 SC duplex PC 9R302xxx<br />
6 SC duplex PC - 6 SC duplex PC 9R303xxx<br />
12 LC duplex PC - 12 LC duplex PC 9R304xxx<br />
12 E2000 simplex PC - 12 E2000 simplex PC 9R305xxx<br />
6 LC duplex PC - 12 E2000 simplex PC 9R306xxx<br />
Configuration:<br />
Art. no.:<br />
6 LC duplex PC - 1 MTP ® /MPO (OS2) 9R700001<br />
12 LC duplex PC - 2 MTP ® /MPO (OS2) 9R700002<br />
6 LC duplex PC - 1 MTP ® /MPO (OM4) 9R700003<br />
12 LC duplex PC - 2 MTP ® /MPO (OM4) 9R700004<br />
6 LC duplex PC - 1 MTP ® /MPO (OM3) 9R700005<br />
12 LC duplex PC - 2 MTP ® /MPO (OM3) 9R700006<br />
Other configurations on request. xxx = Length between the link<br />
modules in m. Pcs. per packing unit: 1<br />
Pcs. per packing unit: 1
20 GigaLineNet ® DC<br />
www.leoni-infrastructure-datacom.com<br />
Trunks GigaLineNet ® DClink<br />
GigaLineNet ® DClink<br />
MTP ® /MPO trunk 12 and 24 OS2<br />
Product description:<br />
Fully pre-assembled MTP ® /MPO trunk<br />
with one or two MTP ® /MPO connectors<br />
at one or both ends.<br />
GigaLineNet ® DClink<br />
MTP ® /MPO trunk 12 and 24 OM4<br />
Product description:<br />
Fully pre-assembled MTP ® /MPO trunk<br />
with one or two MTP ® /MPO connectors<br />
at one or both ends.<br />
GigaLineNet ® DClink<br />
MTP ® /MPO trunk 12 and 24 OM3<br />
Product description:<br />
Fully pre-assembled MTP ® /MPO trunk<br />
with one or two MTP ® /MPO connectors<br />
at one or both ends.<br />
Field of application:<br />
Installation in data centers and in structured<br />
in-house cabling systems to ISO/IEC 11801<br />
and EN 50173 (2nd edition). Suitable for all<br />
applications up to class OF-10000.<br />
Cable:<br />
GigaLine<br />
®<br />
I-F(ZN)H 1x12 or I-F(ZN)<br />
HH 2x12 E9/125 0.36F3.5 0.22H18 OS2<br />
(ITU G652.D)<br />
Tensile strength: 400 N (1x12) - 800 N (2x12)<br />
Flame-retardant and halogen-free outer<br />
sheath<br />
Colour: yellow<br />
Sheath diameter: 3 mm (1x12),<br />
8.9 mm (2x12)<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
Connector:<br />
Connector: MTP® /MPO (US Conec)<br />
■■<br />
■■<br />
Standard: IEC 61754-7<br />
■■<br />
■■<br />
■■<br />
Colour coding: green<br />
Insertion loss: typ. 0.25 dB<br />
Return loss: >55 dB (SM APC)<br />
Field of application:<br />
Installation in data centers and in structured<br />
in-house cabling systems to ISO/IEC 11801<br />
and EN 50173 (2nd edition). Suitable for all<br />
applications in classes >OF-300 (FLine 550,<br />
10 GBE), OF-500 (GBE/Fiber Channel) and<br />
OF-2000 (Fast Ethernet).<br />
Cable:<br />
GigaLine<br />
®<br />
I-F(ZN)H 1x12 or I-F(ZN)HH<br />
2x12G50/125 2.5B3500 0.7F500 OM4<br />
(IEC 60793-2 A1a.3)<br />
Laser bandwidth: 4700 MHz x km<br />
Tensile strength: 400 N (1x12), 800 N (2x12)<br />
Flame-retardant and halogen-free outer<br />
sheath<br />
Colour: magenta<br />
Sheath diameter: 3 mm (1x12)<br />
8.9 mm (2X12)<br />
■■<br />
■ ■<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
Connector:<br />
MTP® /MPO (US Conec)<br />
■■<br />
■■<br />
Standard: IEC 61754-7<br />
■■<br />
■■<br />
■■<br />
Colour coding: aqua<br />
Insertion loss: typ. 0.25 dB<br />
Return loss: >20 dB (MM)<br />
Field of application:<br />
Installation in data centers and in structured<br />
in-house cabling systems to ISO/IEC 11801<br />
and EN 50173 (2nd edition). Suitable for all<br />
applications in classes OF-300 (10 GBE),<br />
OF-500 (GBE/Fiber Channel) and OF-2000<br />
(Fast Ethernet).<br />
Cable:<br />
GigaLine<br />
®<br />
I-F(ZN)H 1x12 or I-F(ZN)HH<br />
2x12 G50/125 2.5B3500 0.7F500 OM3<br />
(IEC 60793-2 A1a.2)<br />
Laser bandwidth: 2000 MHz x km<br />
Tensile strength: 400 N (1x12), 800 N (2x12)<br />
Flame-retardant and halogen-free outer<br />
sheath<br />
Colour: aqua<br />
Sheath diameter: 3 mm (1x12)<br />
8.9 mm (2X12)<br />
■■<br />
■ ■<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
Connector:<br />
MTP® /MPO (US Conec)<br />
■■<br />
■■<br />
Standard: IEC 61754-7<br />
■■<br />
■■<br />
■■<br />
Colour coding: aqua<br />
Insertion loss: typ. 0.25 dB<br />
Return loss: >20 dB (MM)<br />
Configuration:<br />
Art. no.:<br />
1 MTP ® /MPO - 1 MTP ® /MPO OS2 9R711xxx<br />
2 MTP ® /MPO - 2 MTP ® /MPO OS2 9R712xxx<br />
Configuration:<br />
Art. no.:<br />
1 MTP ® /MPO - 1 MTP ® /MPO OM4 9R713xxx<br />
2 MTP ® /MPO - 2 MTP ® /MPO OM4 9R714xxx<br />
Configuration:<br />
Art. no.:<br />
1 MTP ® /MPO - 1 MTP ® /MPO OM3 9R715xxx<br />
2 MTP ® /MPO - 2 MTP ® /MPO OM3 9R716xxx<br />
xxx = Length in m.<br />
Pcs. per packing unit: 1<br />
xxx = Length in m.<br />
Pcs. per packing unit: 1<br />
xxx = Length in m.<br />
Pcs. per packing unit: 1
GigaLineNet ® DCflex<br />
(Fiber optic connection technology)
22 GigaLineNet ® DC<br />
www.leoni-infrastructure-datacom.com<br />
Distributor housing GigaLineNet ® DCflex<br />
GigaLineNet ® DCflex box, 19",<br />
1 RU, fixed<br />
Product description:<br />
Box for the flexible installation of preassembled<br />
fiber optic cables (trunks). Rear<br />
can be equipped with 1 RU back panel,<br />
dummy, or back panel for 12 trunks or back<br />
panel for 8 M25 cable glands<br />
GigaLineNet ® DCflex box, 19",<br />
2 RU, fixed<br />
Product description:<br />
Box for the flexible installation of preassembled<br />
fiber optic cables (trunks). Rear<br />
can be equipped with 1 RU back panel,<br />
dummy, or back panel for 12 trunks or back<br />
panel for 8 M25 cable glands<br />
GigaLineNet ® DCflex box, 19",<br />
3 RU, fixed<br />
Product description:<br />
Box for the flexible installation of preassembled<br />
fiber optic cables (trunks). Rear<br />
can be equipped with 1 RU back panel,<br />
dummy, or back panel for 12 trunks or back<br />
panel for 8 M25 cable glands<br />
Field of application:<br />
For use in data centers for holding partition<br />
front panels with fiber optic adapters<br />
or dummy panels. (2 x TFP2 or 3 x TFP3, TFP<br />
not included in scope of delivery)<br />
Field of application:<br />
For use in data centers for holding partition<br />
front panels with fiber optic adapters<br />
or dummy panels. (2 x TFP2 or 3 x TFP3, TFP<br />
not included in scope of delivery)<br />
Field of application:<br />
For use in data centers for holding partition<br />
front panels with fiber optic adapters<br />
or dummy panels. (2 x TFP2 or 3 x TFP3, TFP<br />
not included in scope of delivery)<br />
■■<br />
■■<br />
Housing: aluminium<br />
Front: sheet steel, powder-coated<br />
■■<br />
Colour: light grey RAL 7035<br />
■■<br />
Dimensions: 483 mm x 44 mm x 300 mm<br />
■■<br />
■■<br />
Housing: aluminium<br />
Front: sheet steel, powder-coated<br />
■■<br />
Colour: light grey RAL 7035<br />
■■<br />
Dimensions: 483 mm x 88 mm x 300 mm<br />
■■<br />
■■<br />
Housing: aluminium<br />
Front: sheet steel, powder-coated<br />
■■<br />
Colour: light grey RAL 7035<br />
■■<br />
Dimensions: 483 mm x 132 mm x 300 mm<br />
Configuration:<br />
Art. no.:<br />
Configuration:<br />
Art. no.:<br />
Configuration:<br />
Art. no.:<br />
Box, 1 RU<br />
9RA00001<br />
Box, 2 RU<br />
9RA00002<br />
Box, 3 RU<br />
9RA00003<br />
Pcs. per packing unit: 1<br />
Pcs. per packing unit: 1<br />
Pcs. per packing unit: 1
www.leoni-infrastructure-datacom.com GigaLineNet ® DC 23<br />
Front panels and back panels GigaLineNet ® DCflex<br />
GigaLineNet ® DCflex TFP2,<br />
partial front panel ¹/2 x 19",<br />
1 RU for distribution box<br />
Product description:<br />
Partial front panel for the flexible<br />
configuration of boxes in 1, 2 and 3 RU.<br />
GigaLineNet ® DCflex TFP3,<br />
partial front panel ¹/3 x 19",<br />
1 RU for distribution box<br />
Product description:<br />
Partial front panel for the flexible<br />
configuration of boxes in 1, 2 and 3 RU.<br />
GigaLineNet ® DCflex BP,<br />
back panel,<br />
1 RU for distribution box<br />
Product description:<br />
Back panel for the configuration of boxes in<br />
1, 2 and 3 RU.<br />
■■<br />
Material: sheet steel, powder-coated<br />
■■<br />
Colour: light grey RAL 7035<br />
■■<br />
Dimensions: 208 mm x 41 mm<br />
TFP2 are available in different configurations<br />
(see below).<br />
Configuration:<br />
TFP2 dummy<br />
TFP2-12LC-Dx MM<br />
TFP2-12LC-Dx SM/PC<br />
TFP2-12LC-Dx SM/APC<br />
TFP2-12SC-Dx MM<br />
TFP2-12SC-Dx SM/PC<br />
TFP2-12SC-Dx SM/APC<br />
TFP2-8MU-4C MM<br />
TFP2-16LC-Dx MM<br />
Art. no.:<br />
9RA00020<br />
9RA00021<br />
9RA00022<br />
9RA00023<br />
9RA00024<br />
9RA00025<br />
9RA00026<br />
9RA00027<br />
9RA00028<br />
■■<br />
■■<br />
Material: sheet steel, powder-coated<br />
Dimensions: 139 mm x 41 mm<br />
■■<br />
Colour: light grey RAL 7035<br />
TFP3 are available in different configurations<br />
(see below).<br />
Configuration:<br />
TFP3 dummy<br />
TFP3-8LC-Dx MM<br />
TFP3-8LC-Dx SM/PC<br />
TFP3-8LC-Dx SM/APC<br />
TFP3-8SC-Dx MM<br />
TFP3-8SC-Dx SM/PC<br />
TFP3-8SC-Dx SM/APC<br />
TFP3-4MU-4C MM<br />
Art. no.:<br />
9RA00030<br />
9RA00031<br />
9RA00032<br />
9RA00033<br />
9RA00034<br />
9RA00035<br />
9RA00036<br />
9RA00037<br />
BP are available as dummy panels, as cable<br />
management panels for 12 trunks and for<br />
eight M25 cable glands for routing breakout<br />
cables.<br />
■■<br />
Material: sheet steel, zinc-plated<br />
■■<br />
Colour: light grey RAL 7035<br />
■■<br />
Dimensions: 442 mm x 44 mm<br />
BP are available in different configurations<br />
(see below).<br />
Configuration:<br />
BP dummy<br />
BP-12<br />
BP-8<br />
Art. no.:<br />
9RA00010<br />
9RA00011<br />
9RA00012<br />
Pcs. per packing unit: 1<br />
Other configurations on request<br />
Pcs. per packing unit: 1<br />
Other configurations on request<br />
Pcs. per packing unit: 1<br />
Other configurations on request
24 GigaLineNet ® DC<br />
www.leoni-infrastructure-datacom.com<br />
Trunks GigaLineNet ® DCflex<br />
GigaLineNet ® DCflex trunk OS2<br />
Product description:<br />
Fully pre-assembled fiber optic trunk, with<br />
a divider and fiber optic connectors at one<br />
or both ends.<br />
GigaLineNet ® DCflex trunk OM4<br />
Product description:<br />
Fully pre-assembled fiber optic trunk, with<br />
a divider and fiber optic connectors at one<br />
or both ends.<br />
GigaLineNet ® DCflex trunk OM3<br />
Product description:<br />
Fully pre-assembled fiber optic trunk, with<br />
a divider and fiber optic connectors at one<br />
or both ends.<br />
Field of application:<br />
Installation in data centers and in structured<br />
in-house cabling systems to ISO/IEC 11801<br />
and EN 50173 (2nd edition).<br />
Suitable for all applications up to class<br />
OF-10000.<br />
Pigtail length: stepped, 45 cm to 75 cm<br />
Connector protector: fabric tube<br />
Field of application:<br />
Installation in data centers and in structured<br />
in-house cabling systems to ISO/IEC 11801<br />
and EN 50173 (2nd edition). Suitable for all<br />
applications up to class OF-300 (10GBE).<br />
Pigtail length: stepped, 45 cm to 75 cm<br />
Connector protector: fabric tube<br />
Field of application:<br />
Installation in data centers and in structured<br />
in-house cabling systems to ISO/IEC 11801<br />
and EN 50173 (2nd edition). Suitable for all<br />
applications up to class OF-300 (10GBE).<br />
Pigtail length: stepped, 45 cm to 75 cm<br />
Connector protector: fabric tube<br />
Cable:<br />
■■<br />
GigaLine<br />
®<br />
DQ 100 U OS2 KL-U-DQ(ZN)<br />
BH 1x12 or 1x24 E9/125 0.36F3.5/0.22H18<br />
(ITU G652.D)<br />
■■<br />
Tensile strength: 1750 N<br />
■■<br />
Flame-retardant and halogen-free outer<br />
sheath<br />
■■<br />
Sheath diameter: approx. 7 or 7.5 mm<br />
■■<br />
Divider: aluminium, diameter 25/33 mm<br />
with slot for insertion in FLine ® and VKT<br />
housing<br />
■■<br />
Assembly: LC duplex, SC duplex, SC<br />
simplex, E2000 simplex<br />
■■<br />
Insertion loss: typ. 0.2 dB<br />
■■<br />
Return loss: >40 dB (PC), >70 dB (APC)<br />
Cable:<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
GigaLine<br />
®<br />
DQ 500 U OM4 KL-U-DQ(ZN)BH<br />
1x12 or 1x24 G50/125 2.5B3500 0.7F500<br />
(ITU G651)<br />
Laser bandwidth: 4700 MHz x km<br />
Tensile strength: 1750 N<br />
Flame-retardant and halogen-free outer<br />
sheath<br />
Sheath diameter: approx. 7 or 7.5 mm<br />
Divider: aluminium, diameter 25/33 mm<br />
with slot for insertion in FLine ® and VKT<br />
housing.<br />
Assembly: LC duplex, SC duplex, SC<br />
simplex, E2000 simplex<br />
Insertion loss: typ. 0.2 dB<br />
Return loss: >35 dB<br />
Cable:<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
GigaLine<br />
®<br />
DQ 500 U OM3 KL-U-DQ(ZN)BH<br />
1x12 or 1x24 G50/125 2.5B3500 0.7F500<br />
(ITU G651)<br />
Laser bandwidth: 1500 MHz x km<br />
Tensile strength: 1750 N<br />
Flame-retardant and halogen-free outer<br />
sheath<br />
Sheath diameter: approx. 7 or 7.5 mm<br />
Divider: aluminium, diameter 25/33 mm<br />
with slot for insertion in FLine ® and VKT<br />
housing.<br />
Assembly: LC duplex, SC duplex, SC<br />
simplex, E2000 simplex<br />
Insertion loss: typ. 0.2 dB<br />
Return loss: >35 dB<br />
Configuration:<br />
Art. no.:<br />
2x 6 LC duplex PC<br />
9RC01xxx<br />
6 LC duplex PC to 6 SC duplex PC 9RC02xxx<br />
2x 6 SC duplex PC<br />
9RC03xxx<br />
2x 12 LC duplex PC<br />
9RC04xxx<br />
2x 12 E2000 simplex PC<br />
9RC05xxx<br />
12 LC duplex PC to 24 E2000<br />
9RC06xxx<br />
simplex PC<br />
Configuration:<br />
Art. no.:<br />
2x 6 LC duplex<br />
9RB01xxx<br />
6 LC duplex to 6 SC duplex 9RB02xxx<br />
2x 6 SC duplex<br />
9RB03xxx<br />
2x 12 LC duplex<br />
9RB04xxx<br />
2x 12 E2000 simplex<br />
9RB05xxx<br />
12 LC duplex to 24 E2000 simplex 9RB06xxx<br />
2x 24 LC duplex<br />
9RB07xxx<br />
2x 32 MU duplex<br />
9RB08xxx<br />
Configuration:<br />
Art. no.:<br />
2x 6 LC duplex<br />
9RF01xxx<br />
6 LC duplex to 6 SC duplex 9RF02xxx<br />
2x 6 SC duplex<br />
9RF03xxx<br />
2x 12 LC duplex<br />
9RF04xxx<br />
2x 12 E2000 simplex<br />
9RF05xxx<br />
12 LC duplex to 24 E2000 simplex 9RF06xxx<br />
2x 24 LC duplex<br />
9RF07xxx<br />
2x 32 MU duplex<br />
9RF08xxx
www.leoni-infrastructure-datacom.com GigaLineNet ® DC 25<br />
MiniZip patch cords GigaLineNet ®<br />
GigaLineNet ® patch cord OS2<br />
Product description:<br />
Configuration: LC duplex, SC duplex,<br />
SC simplex, E2000 simplex<br />
Insertion loss: typ. 0.2 dB<br />
Return loss: >45 dB (PC)<br />
>70 dB (APC)<br />
GigaLineNet ® patch cord OM4<br />
Product description:<br />
Configuration: LC duplex, SC duplex,<br />
SC simplex, E2000 simplex, MU<br />
Insertion loss: typ. 0.2 dB<br />
Return loss: >35 dB<br />
Laser bandwidth: 4700 MHz x km<br />
GigaLineNet ® patch cord OM3<br />
Product description:<br />
Configuration: LC duplex, SC duplex,<br />
SC simplex, E2000 simplex, MU<br />
Insertion loss: typ. 0.2 dB<br />
Return loss: >35<br />
Laser bandwidth: 2000 MHz x km<br />
Cable:<br />
Two semi-tight buffered fibers in figure<br />
8-form with strain relief.<br />
Strain relief elements: aramid<br />
Sheath: halogen-free compound<br />
Colour of sheath: yellow<br />
Cable:<br />
Two semi-tight buffered fibers in figure<br />
8-form with strain relief.<br />
Strain relief elements: aramid<br />
Sheath: halogen-free compound<br />
Colour of sheath: magenta<br />
Cable:<br />
Two semi-tight buffered fibers in figure<br />
8-form with strain relief.<br />
Strain relief elements: aramid<br />
Sheath: halogen-free compound<br />
Colour of sheath: aqua<br />
Temperature range:<br />
■■<br />
Transport and storage: –25 °C to +70 °C<br />
■■<br />
Installation: –5 °C to +50 °C<br />
■■<br />
Operation: –10 °C to +70 °C<br />
Temperature range:<br />
■■<br />
Transport and storage: –25 °C to +70 °C<br />
■■<br />
Installation: –5 °C to +50 °C<br />
■■<br />
Operation: –10 °C to +70 °C<br />
Temperature range:<br />
■■<br />
Transport and storage: –25 °C to +70 °C<br />
■■<br />
Installation: –5 °C to +50 °C<br />
■■<br />
Operation: –10 °C to +70 °C<br />
Bending radius (over flat side):<br />
After installation: 30 mm<br />
During installation: 60 mm<br />
Bending radius (over flat side):<br />
After installation: 30 mm<br />
During installation: 60 mm<br />
Bending radius (over flat side):<br />
After installation: 30 mm<br />
During installation: 60 mm<br />
Fire performance:<br />
Flame retardancy: IEC 60332-1, IEC 60332-3-24<br />
Smoke density: IEC 61034<br />
Halogen-free: IEC 60754-2<br />
Fire performance:<br />
Flame retardancy: IEC 60332-1, IEC 60332-3-24<br />
Smoke density: IEC 61034<br />
Halogen-free: IEC 60754-2<br />
Fire performance:<br />
Flame retardancy: IEC 60332-1, IEC 60332-3-24<br />
Smoke density: IEC 61034<br />
Halogen-free: IEC 60754-2<br />
Configuration:<br />
Art. no.:<br />
Configuration:<br />
Art. no.:<br />
Configuration:<br />
Art. no.:<br />
2x LC/PC-Dx-OS2 (2 m)<br />
9A130033<br />
2x LC-Dx-OM4 (2 m)<br />
9A110693<br />
2x LC-Dx-OM3 (2 m)<br />
9A110699<br />
2x LC/APC-Dx-OS2 (2 m)<br />
9A130090<br />
2x SC-Dx-OM4 (2 m)<br />
9A110694<br />
2x SC-Dx-OM3 (2 m)<br />
9A110700<br />
2x SC/PC-Dx-OS2 (2 m)<br />
9A130091<br />
2x E2000-Dx-OM4 (2 m)<br />
9A110695<br />
2x E2000-Dx-OM3 (2 m)<br />
9A110701<br />
2x SC/APC-Dx-OS2 (2 m)<br />
9A130092<br />
2x MU-OM4 (2 m)<br />
9A110696<br />
2x MU-OM3 (2 m)<br />
9A110702<br />
2x E2000/PC-Dx-OS2 (2 m)<br />
9A130093<br />
2x E2000/APC-Dx-OS2 (2 m)<br />
9A130094<br />
Other configurations on request<br />
Other configurations on request<br />
Other configurations on request<br />
Pcs. per packing unit: 1<br />
Pcs. per packing unit: 1<br />
Pcs. per packing unit: 1
26 GigaLineNet ® DC<br />
www.leoni-infrastructure-datacom.com<br />
LC Uniboot patch cords GigaLineNet ®<br />
GigaLineNet® LC Uniboot<br />
patch cord OS2<br />
Product description:<br />
Configuration: LC duplex uniboot<br />
Insertion loss: 35 dB (PC)<br />
GigaLineNet® LC Uniboot<br />
patch cord OM4<br />
Product description:<br />
Configuration: LC duplex uniboot<br />
Insertion loss: 35 dB (PC)<br />
Laser bandwidth: 4700 MHz x km<br />
GigaLineNet® LC Uniboot<br />
patch cord OM3<br />
Product description:<br />
Configuration: LC duplex uniboot<br />
Insertion loss: 35 dB (PC)<br />
Laser bandwidth: 1500 MHz x km<br />
Cable:<br />
Two semi-tight buffered fibers under<br />
a common sheath (round).<br />
Cable type: KL-I-V(ZN)H 2G 50/125<br />
Cable diameter: 2.8 mm<br />
Strain relief elements: aramid<br />
Sheath: halogen-free compound<br />
Colour of sheath: yellow<br />
Tensile strength: 300 N<br />
Cable:<br />
Two semi-tight buffered fibers under<br />
a common sheath (round).<br />
Cable type: KL-I-V(ZN)H 2G 50/125<br />
Cable diameter: 2.8 mm<br />
Strain relief elements: aramid<br />
Sheath: halogen-free compound<br />
Colour of sheath: magenta<br />
Tensile strength: 300 N<br />
Cable:<br />
Two semi-tight buffered fibers under<br />
a common sheath (round).<br />
Cable type: KL-I-V(ZN)H 2G 50/125<br />
Cable diameter: 2.8 mm<br />
Strain relief elements: aramid<br />
Sheath: halogen-free compound<br />
Colour of sheath: aqua<br />
Tensile strength: 300 N<br />
Temperature range:<br />
■■<br />
Transport and storage: –25 °C to +70 °C<br />
■■<br />
Installation: –5 °C to +50 °C<br />
■■<br />
Operation: –10 °C to +70 °C<br />
Temperature range:<br />
■■<br />
Transport and storage: –25 °C to +70 °C<br />
■■<br />
Installation: –5 °C to +50 °C<br />
■■<br />
Operation: –10 °C to +70 °C<br />
Temperature range:<br />
■■<br />
Transport and storage: –25 °C to +70 °C<br />
■■<br />
Installation: –5 °C to +50 °C<br />
■■<br />
Operation: –10 °C to +70 °C<br />
Bending radius:<br />
After installation: 30 mm<br />
During installation: 60 mm<br />
Bending radius:<br />
After installation: 30 mm<br />
During installation: 60 mm<br />
Bending radius:<br />
After installation: 30 mm<br />
During installation: 60 mm<br />
Fire performance:<br />
Flame retardancy: IEC 60332-1, IEC 60332-3-24<br />
Smoke density: IEC 61034<br />
Halogen-free: IEC 60754-2<br />
Fire performance:<br />
Flame retardancy: IEC 60332-1, IEC 60332-3-24<br />
Smoke density: IEC 61034<br />
Halogen-free: IEC 60754-2<br />
Fire performance:<br />
Flame retardancy: IEC 60332-1, IEC 60332-3-24<br />
Smoke density: IEC 61034<br />
Halogen-free: IEC 60754-2<br />
Designation:<br />
Art. no.:<br />
Designation:<br />
Art. no.:<br />
Designation:<br />
Art. no.:<br />
LCDU – LCDU OS2 – 1 m<br />
9A110848<br />
LCDU – LCDU OM4 – 1 m<br />
9A110875<br />
LCDU – LCDU OM3 – 1 m<br />
9A110866<br />
LCDU – LCDU OS2 – 2 m<br />
9A110850<br />
LCDU – LCDU OM4 – 2 m<br />
9A110877<br />
LCDU – LCDU OM3 – 2 m<br />
9A110868<br />
LCDU – LCDU OS2 – 3 m<br />
9A110852<br />
LCDU – LCDU OM4 – 3 m<br />
9A110879<br />
LCDU – LCDU OM3 – 3 m<br />
9A110870<br />
LCDU – LCDU OS2 – 5 m<br />
9A110853<br />
LCDU – LCDU OM4 – 5 m<br />
9A110880<br />
LCDU – LCDU OM3 – 5 m<br />
9A110871<br />
LCDU – LCDU OS2 – 7.5 m<br />
9A110854<br />
LCDU – LCDU OM4 – 7.5 m<br />
9A110881<br />
LCDU – LCDU OM3 – 7.5 m<br />
9A110872<br />
LCDU – LCDU OS2 – 10 m<br />
9A110855<br />
LCDU – LCDU OM4 – 10 m<br />
9A110882<br />
LCDU – LCDU OM3 – 10 m<br />
9A110873
www.leoni-infrastructure-datacom.com GigaLineNet ® DC 27<br />
Distribution Boxes GigaLineNet ®<br />
GigaLineNet ® Smart Box, fixed 19", 1 RU,<br />
48 LC duplex<br />
Product description:<br />
■■<br />
■■<br />
■■<br />
For supporting max. 2 trunks<br />
Equipped with 48 LC duplex adapters<br />
• Multi-mode: plastic/PhBz, beige<br />
• Single-mode/PC: plastic/zirconia, blue<br />
• Single-mode/APC: plastic/zirconia, green<br />
Housing made from zinc-plated sheet steel<br />
■■<br />
Colour: light grey RAL 7035<br />
■■<br />
Screen printing inscription 1-48<br />
■■<br />
Dimensions: 483 mm x 1 RU x 98 mm (WxHxD)<br />
GigaLineNet ® Smart Box, telescopic 19", 1 RU,<br />
48 LC duplex<br />
Product description:<br />
■■<br />
■■<br />
■■<br />
For supporting max. 2 trunks<br />
Equipped with 48 LC duplex adapters<br />
• Multimode: plastic/PhBz, beige<br />
• Single-mode/PC: plastic/zirconia, blue<br />
• Single-mode/APC: plastic/zirconia, green<br />
Housing made from zinc-plated sheet steel<br />
■■<br />
Colour: light grey RAL 7035<br />
■■<br />
Screen printing inscription 1-48<br />
■■<br />
Dimensions: 483 mm x 1 RU x 98 mm (WxHxD)<br />
Other GigaLineNet ® Smart Boxes on request<br />
Other GigaLineNet ® Smart Boxes on request<br />
Fiber type:<br />
Art. no.:<br />
Fiber type:<br />
Art. no.:<br />
MM<br />
9D420085<br />
MM<br />
9D320151<br />
SM/PC<br />
On request<br />
SM/PC<br />
On request<br />
SM/APC<br />
On request<br />
SM/APC<br />
On request<br />
Pcs. per packing unit: 1<br />
Pcs. per packing unit: 1
28 Generic communications cabling<br />
www.leoni-infrastructure-datacom.com<br />
Structure of generic communications cabling<br />
ENI<br />
MD<br />
MD<br />
Distributor<br />
to EN 50173-1<br />
Network access cabling<br />
Main distribution cabling
www.leoni-infrastructure-datacom.com Generic communications cabling 29<br />
LDP EO EQP<br />
Zone distribution cabling<br />
Equipment cabling<br />
ENI:<br />
MD:<br />
ZD:<br />
LDP:<br />
EO:<br />
EQP:<br />
External network interface<br />
Main distributor<br />
Zone distributor<br />
Local distribution point (optional)<br />
External network interface<br />
Transmission equipment
30 Index<br />
www.leoni-infrastructure-datacom.com<br />
Page Product Art. no.<br />
9 VarioLine ® DC CMP1, black 9ZE30050<br />
9 VarioLine ® DC CMP1, grey 9ZE10006<br />
9 VarioLine ® DC CMP2, grey 9A610028<br />
9 VarioLine ® DC CMP3, grey 9A610020<br />
10 VarioLine ® DClink frame, 19", 1 RU 9R000000<br />
10 VarioLine ® DClink dummy cover 9R000001<br />
11 VarioLine ® DClink frame for 2 six-way jacks 9R000003<br />
11 VarioLine ® DClink six-way jack dummy 9R000004<br />
11 VarioLine ® DClink extracting tool 9R000002<br />
13 MegaLineNet ® DClink “40/100 GigaBit Ethernet” six-way jack 9R400xxx<br />
13 MegaLineNet ® DClink 10 GigaBit Ethernet six-way jack 9R500xxx<br />
15 <strong>LEONI</strong> CX4 patch cord 9R8CXxxx<br />
15 <strong>LEONI</strong> InfiniBand ® patch cord for SDR transmission 9R8SDxxx<br />
15 <strong>LEONI</strong> InfiniBand ® patch cord for DDR transmission 9R8DDxxx<br />
16 ELine 1200 ® EC7 patch cord “40/100” GBE 1.0 m 9KEO1010<br />
16 ELine 1200 ® EC7 patch cord “40/100” GBE 2.0 m 9KEO1020<br />
16 ELine 1200 ® EC7 patch cord “40/100” GBE 3.0 m 9KEO1030<br />
16 ELine 1200 ® EC7 patch cord “40/100” GBE 5.0 m 9KEO1050<br />
16 ELine 1200 ® EC7 patch cord 10GBE 1.0 m 9KEC1010<br />
16 ELine 1200 ® EC7 patch cord 10GBE 2.0 m 9KEC1020<br />
16 ELine 1200 ® EC7 patch cord 10GBE 3.0 m 9KEC1030<br />
16 ELine 1200 ® EC7 patch cord 10GBE 5.0 m 9KEC1050<br />
16 Patch cord RJ45/RJ45 500 MHz shielded 1.0 m 9A020383<br />
16 Patch cord RJ45/RJ45 500 MHz shielded 2.0 m 9A020385<br />
16 Patch cord RJ45/RJ45 500 MHz shielded 3.0 m 9A020387<br />
16 Patch cord RJ45/RJ45 500 MHz shielded 5.0 m 9A020389<br />
18 GigaLineNet ® DClink OS2 - 6 LC duplex PC - 6 LC duplex PC 9R201xxx<br />
18 GigaLineNet ® DClink OS2 - 6 LC duplex PC - 6 SC duplex PC 9R202xxx<br />
18 GigaLineNet ® DClink OS2 - 6 SC duplex PC - 6 SC duplex PC 9R203xxx<br />
18 GigaLineNet ® DClink OS2 - 12 LC duplex PC - 12 LC duplex PC 9R204xxx<br />
18 GigaLineNet ® DClink OS2 - 12 E2000 simplex PC - 12 E2000 simplex PC 9R205xxx<br />
18 GigaLineNet ® DClink OS2 - 6 LC duplex PC - 12 E2000 simplex PC 9R206xxx<br />
18 GigaLineNet ® DClink OM4 - 6 LC duplex PC - 6 LC duplex PC 9R101xxx<br />
18 GigaLineNet ® DClink OM4 - 6 LC duplex PC - 6 SC duplex PC 9R102xxx<br />
18 GigaLineNet ® DClink OM4 - 6 SC duplex PC - 6 SC duplex PC 9R103xxx<br />
18 GigaLineNet ® DClink OM4 - 12 LC duplex PC -12 LC duplex PC 9R104xxx<br />
18 GigaLineNet ® DClink OM4 - 12 E2000 simplex PC - 12 E2000 simplex PC 9R105xxx<br />
18 GigaLineNet ® DClink OM4 - 6 LC duplex PC - 12 E2000 simplex PC 9R106xxx<br />
19 GigaLineNet ® DClink OM3 - 6 LC duplex PC - 6 LC duplex PC 9R301xxx<br />
19 GigaLineNet ® DClink OM3 - 6 LC duplex PC - 6 SC duplex PC 9R302xxx<br />
19 GigaLineNet ® DClink OM3 - 6 SC duplex PC - 6 SC duplex PC 9R303xxx<br />
19 GigaLineNet ® DClink OM3 - 12 LC duplex PC -12 LC duplex PC 9R304xxx<br />
19 GigaLineNet ® DClink OM3 - 12 E2000 simplex PC - 12 E2000 simplex PC 9R305xxx<br />
19 GigaLineNet ® DClink OM3 - 6 LC duplex PC - 12 E2000 simplex PC 9R306xxx<br />
19 GigaLineNet ® MTP ® /MPO module - 6LC duplex PC - 1MTP ® /MPO OS2 9R700001<br />
19 GigaLineNet ® MTP ® /MPO module - 12LC duplex PC - 2MTP ® /MPO OS2 9R700002<br />
19 GigaLineNet ® MTP ® /MPO module - 6LC duplex PC - 1MTP ® /MPO OM4 9R700003<br />
19 GigaLineNet ® MTP ® /MPO module - 12LC duplex PC - 2MTP ® /MPO OM4 9R700004<br />
19 GigaLineNet ® MTP ® /MPO module - 6LC duplex PC - 1MTP ® /MPO OM3 9R700005<br />
19 GigaLineNet ® MTP ® /MPO module - 12LC duplex PC - 2MTP ® /MPO OM3 9R700006<br />
20 GigaLineNet ® trunk 1 MTP ® /MPO - 1 MTP ® /MPO - 12 OS2 9R711xxx<br />
20 GigaLineNet ® trunk 2 MTP ® /MPO - 2 MTP ® /MPO - 24 OS2 9R712xxx<br />
20 GigaLineNet ® trunk 1 MTP ® /MPO - 1 MTP ® /MPO - 12 OM4 9R713xxx<br />
20 GigaLineNet ® trunk 2 MTP ® /MPO - 2 MTP ® /MPO - 24 OM4 9R714xxx<br />
20 GigaLineNet ® trunk 1 MTP ® /MPO - 1 MTP ® /MPO - 12 OM3 9R715xxx<br />
20 GigaLineNet ® trunk 2 MTP ® /MPO - 2 MTP ® /MPO - 24 OM3 9R716xxx<br />
22 GigaLineNet ® DCflex - box, 19", 1 RU 9RA00001<br />
22 GigaLineNet ® DCflex - box, 19", 2 RU 9RA00002<br />
22 GigaLineNet ® DCflex - box, 19", 3 RU 9RA00003<br />
23 GigaLineNet ® DCflex-TFP2 dummy 9RA00020<br />
23 GigaLineNet ® DCflex - TFP2-12LC-Dx MM 9RA00021<br />
23 GigaLineNet ® DCflex - TFP2-12LC-Dx SM/PC 9RA00022<br />
23 GigaLineNet ® DCflex - TFP2-12LC-Dx SM/APC 9RA00023<br />
23 GigaLineNet ® DCflex - TFP2-12SC-Dx MM 9RA00024<br />
23 GigaLineNet ® DCflex - TFP2-12SC-Dx SM/PC 9RA00025<br />
23 GigaLineNet ® DCflex - TFP2-12SC-Dx SM/APC 9RA00026<br />
23 GigaLineNet ® DCflex - TFP2-8MU-4C MM 9RA00027<br />
23 GigaLineNet ® DCflex - TFP2-16LC-Dx MM 9RA00028<br />
Page Product Art. no.<br />
23 GigaLineNet ® DCflex - TFP3 dummy 9RA00030<br />
23 GigaLineNet ® DCflex - TFP3-8LC-Dx MM 9RA00031<br />
23 GigaLineNet ® DCflex - TFP3-8LC-Dx SM/PC 9RA00032<br />
23 GigaLineNet ® DCflex - TFP3-8LC-Dx SM/APC 9RA00033<br />
23 GigaLineNet ® DCflex - TFP3-8SC-Dx MM 9RA00034<br />
23 GigaLineNet ® DCflex - TFP3-8SC-Dx SM/PC 9RA00035<br />
23 GigaLineNet ® DCflex - TFP3-8SC-Dx SM/APC 9RA00036<br />
23 GigaLineNet ® DCflex - TFP3-4 MU-4C MM 9RA00037<br />
23 GigaLineNet ® DCflex - BP dummy 9RA00010<br />
23 GigaLineNet ® DCflex - BP-12 9RA00011<br />
23 GigaLineNet ® DCflex - BP-8 9RA00012<br />
24 GigaLineNet ® trunk OS2 - 6 LC duplex PC - 6 LC duplex PC 9RC01xxx<br />
24 GigaLineNet ® trunk OS2 - 6 LC duplex PC - 6 SC duplex PC 9RC02xxx<br />
24 GigaLineNet ® trunk OS2 - 6 SC duplex PC - 6 SC duplex PC 9RC03xxx<br />
24 GigaLineNet ® trunk OS2 - 12 LC duplex PC -12 LC duplex PC 9RC04xxx<br />
24 GigaLineNet ® trunk OS2 - 12 E2000 simplex PC - 12 E2000 simplex PC 9RC05xxx<br />
24 GigaLineNet ® trunk OS2 - 12LC duplex PC - 24 E2000 simplex PC 9RC06xxx<br />
24 GigaLineNet ® trunk OM4 - 6 LC duplex - 6 LC duplex 9RB01xxx<br />
24 GigaLineNet ® trunk OM4 - 6 LC duplex - 6 SC duplex 9RB02xxx<br />
24 GigaLineNet ® trunk OM4 - 6 SC duplex - 6 SC duplex 9RB03xxx<br />
24 GigaLineNet ® trunk OM4 - 12 LC duplex - 12 LC duplex 9RB04xxx<br />
24 GigaLineNet ® trunk OM4 - 12 E2000 simplex - 12 E2000 simplex 9RB05xxx<br />
24 GigaLineNet ® trunk OM4 - 12 LC duplex - 24 E2000 simplex 9RB06xxx<br />
24 GigaLineNet ® trunk OM4 - 24 LC duplex - 24 LC duplex 9RB07xxx<br />
24 GigaLineNet ® trunk OM4 - 32 MU - 32 MU 9RB08xxx<br />
24 GigaLineNet ® trunk OM3 - 6 LC duplex - 6 LC duplex 9RF01xxx<br />
24 GigaLineNet ® trunk OM3 - 6 LC duplex - 6 SC duplex 9RF02xxx<br />
24 GigaLineNet ® trunk OM3 - 6 SC duplex - 6 SC duplex 9RF03xxx<br />
24 GigaLineNet ® trunk OM3 - 12 LC duplex - 12 LC duplex 9RF04xxx<br />
24 GigaLineNet ® trunk OM3 - 12 E2000 simplex - 12 E2000 simplex 9RF05xxx<br />
24 GigaLineNet ® trunk OM3 - 12 LC duplex - 24 E2000 simplex 9RF06xxx<br />
24 GigaLineNet ® trunk OM3 - 24 LC duplex - 24 LC duplex 9RF07xxx<br />
24 GigaLineNet ® trunk OM3 - 32 MU - 32 MU 9RF08xxx<br />
25 GigaLineNet ® MiniZip patch cord LC/PC-Dx-LC/PC-Dx-OS2 - 2 m 9A130033<br />
25 GigaLineNet ® MiniZip patch cord LC/APC-Dx-LC/APC-Dx-OS2 - 2 m 9A130090<br />
25 GigaLineNet ® MiniZip patch cord SC/PC-Dx-SC/PC-Dx-OS2 - 2 m 9A130091<br />
25 GigaLineNet ® MiniZip patch cord SC/APC-Dx-SC/APC-Dx-OS2 - 2 m 9A130092<br />
25 GigaLineNet ® MiniZip patch cord E2000/PC-Dx-E2000/PC-Dx-OS2 - 2 m 9A130093<br />
25 GigaLineNet ® MiniZip patch cord E2000/APC-Dx-E2000/APC-Dx-OS2 - 2 m 9A130094<br />
25 GigaLineNet ® MiniZip patch cord LC-Dx-LC-Dx-OM4 - 2 m 9A110693<br />
25 GigaLineNet ® MiniZip patch cord SC-Dx-SC-Dx-OM4 - 2 m 9A110694<br />
25 GigaLineNet ® MiniZip patch cord E2000-Dx-E2000-Dx-OM4 - 2 m 9A110695<br />
25 GigaLineNet ® MiniZip patch cord MU duplex - MU duplex-OM4 - 2 m 9A110696<br />
25 GigaLineNet ® MiniZip patch cord LC-Dx-LC-Dx-OM3 - 2 m 9A110699<br />
25 GigaLineNet ® MiniZip patch cord SC-Dx-SC-Dx-OM3 - 2 m 9A110700<br />
25 GigaLineNet ® MiniZip patch cord E2000-Dx-E2000-Dx-OM3 - 2 m 9A110701<br />
25 GigaLineNet ® MiniZip patch cord MU duplex - MU duplex-OM3 - 2 m 9A110702<br />
26 GigaLineNet ® LCDU-LCDU OS2 - 1 m 9A110848<br />
26 GigaLineNet ® LCDU-LCDU OS2 - 2 m 9A110850<br />
26 GigaLineNet ® LCDU-LCDU OS2 - 3 m 9A110852<br />
26 GigaLineNet ® LCDU-LCDU OS2 - 5 m 9A110853<br />
26 GigaLineNet ® LCDU-LCDU OS2 - 7.5 m 9A110854<br />
26 GigaLineNet ® LCDU-LCDU OS2 - 10 m 9A110855<br />
26 GigaLineNet ® LCDU-LCDU OM4 - 1 m 9A110875<br />
26 GigaLineNet ® LCDU-LCDU OM4 - 2 m 9A110877<br />
26 GigaLineNet ® LCDU-LCDU OM4 - 3 m 9A110879<br />
26 GigaLineNet ® LCDU-LCDU OM4 - 5 m 9A110880<br />
26 GigaLineNet ® LCDU-LCDU OM4 - 7.5 m 9A110881<br />
26 GigaLineNet ® LCDU-LCDU OM4 - 10 m 9A110882<br />
26 GigaLineNet ® LCDU-LCDU OM3 - 1 m 9A110866<br />
26 GigaLineNet ® LCDU-LCDU OM3 - 2 m 9A110868<br />
26 GigaLineNet ® LCDU-LCDU OM3 - 3 m 9A110870<br />
26 GigaLineNet ® LCDU-LCDU OM3 - 5 m 9A110871<br />
26 GigaLineNet ® LCDU-LCDU OM3 - 7.5 m 9A110872<br />
26 GigaLineNet ® LCDU-LCDU OM3 - 10 m 9A110873<br />
27 GigaLineNet ® Smart Box, fixed, 48 LC duplex, MM 9D420085<br />
27 GigaLineNet ® Smart Box, telescopic, 48 LC duplex, MM 9D320151
www.leoni-infrastructure-datacom.com<br />
Service<br />
31<br />
Cutting corners with cabling...<br />
Active components 7%<br />
For the configuration of networks, only 5% of the costs are due to<br />
the passive cabling, while the active components account for 7%.<br />
Investment in the workstation represents roughly one third of the<br />
costs (34%), while the biggest cost driver of all is software at 54%.<br />
Workstation 34%<br />
Given the fact that passive cabling has a service life of 15 years,<br />
one thing is certainly clear:<br />
Cutting corners with cabling is a false economy.<br />
Cabling 5%<br />
Software 54%<br />
The following information can be found at:<br />
www.leoni-infrastructure-datacom.com<br />
n <strong>Data</strong> sheets and announcement texts<br />
n Specialist articles<br />
n “Trained Networker” certification programme<br />
n Seminars and roadshows<br />
n News/standards<br />
n Planer DVD
<strong>LEONI</strong> Kerpen GmbH<br />
Business Unit <strong>Infrastructure</strong> & <strong><strong>Data</strong>com</strong><br />
Zweifaller Straße 275–287<br />
52224 Stolberg<br />
Germany<br />
Tel.: +49 (0)2402-17-1<br />
Fax: +49 (0)2402-75154<br />
E-mail: infrastructure-datacom@leoni.com<br />
www.leoni-infrastructure-datacom.com