GX9000 User manual Rev 2.1 Metering and the Display Metering and the Display Metering PPM Peak Display .PPM peak Off Delay On The configuration of the meters can be customized for personal preference. The timecode display also has some level of customization. All of these parameter are accessible through the Setup | Display menu. The characteristics of the Peak Hold for the front panel PPM's is programmable. If Off is selected no peak information is stored, and the PPM's descend normally. If On is selected peak bars remain permanently on until cleared by pressing the Clear Peak Hold button. If Delay is selected peak bars remain on until a delay period has elapsed. The delay period is factory set to 3 seconds. The Overload LED's on the PPM display override all settings under this menu heading. If triggered they will remain on until cleared by the Clear Peak Hold button. PPM Over Display .PPMOver 1 Sample 2 Sample 3 Sample 4 Sample 5 Sample 6 Sample The Overload LED’s light upon continuous detection of digital Peak Level for the number of samples selected here. Vary this setting to match the overload detection to that of an external Analog to Digital Converter which may not flag an overload immediately. The Overload LED’s stay on regardless of the .PPM peak menu heading and can only be cleared using the Clear Peak Hold button. Genex Audio Inc Page 59

GX9000 User manual Rev 2.1 Metering and the Display PPM Scale Display .FinePPM Normal -22dB +/-1 -20dB +/-1 -18dB +/-1 -16dB +/-1 Frames on/off Display .Frames Off On You can expand the PPM scale to cover just 2dB from the top to the bottom, for the purposes of calibration of internal and external ADC’s. The centre pixel can be programmed to represent either –16dBFS, -18dBFS, -20dBFS or -22dBFS. In Expand mode two pixels light for each PPM column until the incoming level is aligned. One pixel shows the incoming level and the centre pixel flashes until the incoming level matches the alignment level. If the incoming level is outside of the expanded range, the bottom or top pixel stays lit to indicate the direction of the error. Expand mode can be cancelled by selecting Normal. • Press the Setup button. • Use the Rotary Wheel and Parameter Up and Parameter Down buttons to select the Display | .FinePPM menu heading. • Press the Value Up and Value Down buttons to select one of the four scales. • Press the Enter button to enter Fine PPM mode. This heading allows the user to not display the frames segment of the Timecode display. Some users prefer to not display these characters to make the timecode more readable. Genex Audio Inc Page 60

<strong>GX9000</strong> User manual Rev 2.1 Metering and the Display<br />

Metering and the Display<br />

Metering<br />

PPM Peak<br />

Display<br />

<br />

<br />

.PPM peak<br />

<br />

Off<br />

Delay<br />

On<br />

The configuration of the meters can be customized for personal preference.<br />

The timecode display also has some level of customization. All of these<br />

parameter are accessible through the Setup | Display menu.<br />

The characteristics of the Peak Hold for the front panel PPM's is<br />

programmable.<br />

If Off is selected no peak information is stored, and the PPM's descend<br />

normally.<br />

If On is selected peak bars remain permanently on until cleared by pressing<br />

the Clear Peak Hold button.<br />

If Delay is selected peak bars remain on until a delay period has elapsed.<br />

The delay period is factory set to 3 seconds.<br />

The Overload LED's on the PPM display override all settings under this menu<br />

heading. If triggered they will remain on until cleared by the Clear Peak Hold<br />

button.<br />

PPM Over<br />

Display<br />

<br />

<br />

.PPMOver<br />

<br />

1 Sample<br />

2 Sample<br />

3 Sample<br />

4 Sample<br />

5 Sample<br />

6 Sample<br />

The Overload LED’s light upon continuous detection of digital Peak Level for<br />

the number of samples selected here.<br />

Vary this setting to match the overload detection to that of an external Analog<br />

to Digital Converter which may not flag an overload immediately.<br />

The Overload LED’s stay on regardless of the .PPM peak menu heading<br />

and can only be cleared using the Clear Peak Hold button.<br />

<strong>Genex</strong> Audio Inc Page 59