MULTI-CONDUCTOR TYPE SOOW - Priority Wire & Cable
MULTI-CONDUCTOR TYPE SOOW - Priority Wire & Cable
MULTI-CONDUCTOR TYPE SOOW - Priority Wire & Cable
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>MULTI</strong>-<strong>CONDUCTOR</strong> <strong>TYPE</strong> <strong>SOOW</strong><br />
90° 600 Volt UL/CSA Portable Cord<br />
Application: For use with control circuits, tools,<br />
heavy industrial, processing and construction equipment.<br />
Specifications: • Conductors: 18 and 16 AWG fully annealed,<br />
stranded bare copper, per ASTM B-174 • Insulation: Premium grade<br />
color coded 90° C CPE, refer to color code chart • Jacket: Temperature<br />
rating -40° C to +90° C CPE • Extra flexible stranding<br />
• Resists flame, ozone, oils, solvents and abrasion • 90° C rated<br />
conducts and jacket • Good flexibility in low temperatures • UL<br />
Listed and CSA Certified for indoor and outdoor use • UL Flexible<br />
Cord UL Subject 62 and CSA Flexible Cord C22.2-49<br />
• OSHA acceptable and MSHA approved, JC 580<br />
Color Code Chart<br />
No. of Color Tracer No. of Color Tracer<br />
Conductors<br />
Conductors<br />
1 Black -- 12 Black White<br />
2 White -- 13 Red White<br />
3 Red -- 14 Green White<br />
4 Green -- 15 Blue White<br />
5 Orange -- 16 Black Red<br />
6 Blue -- 17 White Red<br />
7 White Black 18 Orange Red<br />
8 Red Black 19 Blue Red<br />
9 Green Black 20 Red Green<br />
10 Orange Black 21 Orange Green<br />
11 Blue Black<br />
Catalog No. No. of AWG Conductor Nominal Insulation Nominal Overall Current Weight<br />
Conductors Strand Thickness Diameter Amps LBS/M’<br />
Inches mm Inches mm **<br />
P01M3 5 18 16/30 .030 .76 .465 11.81 5.6 130<br />
P02M3 6 18 16/30 .030 .76 .495 12.57 5.6 150<br />
P03M3 7 18 16/30 .030 .76 .500 12.70 4.9 160<br />
P04M3 8 18 16/30 .030 .76 .530 13.46 4.9 170<br />
P05M3 10 18 16/30 .030 .76 .605 15.37 3.5 215<br />
P06M3 12 18 16/30 .030 .76 .605 15.37 3.5 245<br />
P07M3 14 18 16/30 .030 .76 .660 16.76 3.5 265<br />
P08M3 16 18 16/30 .030 .76 .705 17.90 3.5 310<br />
P09M3 18 18 16/30 .030 .76 .760 19.30 3.5 340<br />
P10M3 20 18 16/30 .030 .76 .795 20.19 3.5 375<br />
P11M3 22 18 16/30 .030 .76 .855 21.72 3.1 415<br />
P12M3 24 18 16/30 .030 .76 .901 22.88 3.1 450<br />
P13M3 27 18 16/30 .030 .76 .920 23.37 3.1 490<br />
P14M3 30 18 16/30 .030 .76 .925 23.50 3.1 520<br />
P15M3 36 18 16/30 .030 .76 1.050 26.64 2.8 600<br />
P16M3 5 16 26/30 .030 .76 .495 12.57 8 160<br />
P17M3 6 16 26/30 .030 .76 .520 13.21 8 175<br />
P18M3 7 16 26/30 .030 .76 .550 13.97 7 195<br />
P19M3 8 16 26/30 .030 .76 .575 14.62 7 220<br />
P20M3 9 16 26/30 .030 .76 .620 15.75 7 250<br />
P21M3 10 16 26/30 .030 .76 .650 16.51 5 280<br />
P22M3 12 16 26/30 .030 .76 .690 17.53 5 325<br />
P23M3 14 16 26/30 .030 .76 .720 18.05 5 355<br />
P24M3 16 16 26/30 .030 .76 .740 18.80 5 380<br />
P25M3 18 16 26/30 .030 .76 .795 20.19 5 425<br />
P26M3 20 16 26/30 .030 .76 .810 20.57 5 480<br />
P27M3 22 16 26/30 .030 .76 .920 23.37 4.5 510<br />
P28M3 24 16 26/30 .030 .76 .925 23.50 4.5 550<br />
P29M3 26 16 26/30 .030 .76 .990 25.15 4.5 635<br />
P30M3 30 16 26/30 .030 .76 1.050 26.67 4.5 715<br />
P31M3 36 16 26/30 .030 .76 1.125 28.58 4 800<br />
P32M3 37 16 26/30 .030 .76 1.185 30.10 4 815<br />
P33M3 40 16 26/30 .030 .76 1.240 31.50 4 850<br />
** Values shown are for current carrying conductors. A grounding conductor,<br />
or one which carries only the unbalanced current from other conductors,<br />
is NOT counted in determining current carrying capacity.
<strong>MULTI</strong>-<strong>CONDUCTOR</strong> <strong>TYPE</strong> <strong>SOOW</strong><br />
90° 600 Volt UL/CSA Portable Cord<br />
Application: For use with control circuits, tools,<br />
heavy industrial, processing and construction equipment.<br />
Specifications: • Conductors: 14 through 10 AWG fully annealed<br />
stranded bare copper per ASTM B-174 • Insulation: Premium<br />
grade color coded 90°C CPE, refer to color code chart.<br />
• Jacket: Temperature Rating -40°C to + 90°C CPE<br />
• Extra flexible stranding • Resists flame, ozone, oils, solvents,<br />
and abrasion • 90°C rated conducts and jacket • UL Listed and<br />
CSA Certified for indoor and outdoor use • UL Flexible Cord<br />
Subject 62 and CSA Flexible Cord C-22.2-49<br />
• OSHA Acceptable and MSHA Approved, JC 580<br />
Color Code Chart<br />
No. of Color Tracer No. of Color Tracer<br />
Conductors<br />
Conductors<br />
1 Black -- 12 Black White<br />
2 White -- 13 Red White<br />
3 Red -- 14 Green White<br />
4 Green -- 15 Blue White<br />
5 Orange -- 16 Black Red<br />
6 Blue -- 17 White Red<br />
7 White Black 18 Orange Red<br />
8 Red Black 19 Blue Red<br />
9 Green Black 20 Red Green<br />
10 Orange Black 21 Orange Green<br />
11 Blue Black<br />
Catalog No. No. of AWG Conductor Nominal Insulation Nominal Overall Current Weight<br />
Conductors Strand Thickness Diameter Amps LBS/M’<br />
Inches mm Inches mm **<br />
P01M4 5 14 41/30 .045 1.14 .650 16.51 12 275<br />
P02M4 6 14 41/30 .045 1.14 .710 18.03 12 315<br />
P03M4 7 14 41/30 .045 1.14 .710 18.03 10.5 345<br />
P04M4 8 14 41/30 .045 1.14 .760 19.30 10.5 385<br />
P05M4 9 14 41/30 .045 1.14 .830 21.08 10.5 410<br />
P06M4 10 14 41/30 .045 1.14 .830 21.08 7.5 430<br />
P07M4 12 14 41/30 .045 1.14 .870 22.10 7.5 485<br />
P08M4 14 14 41/30 .045 1.14 1.000 25.40 7.5 590<br />
P09M4 16 14 41/30 .045 1.14 1.030 26.16 7.5 665<br />
P10M4 18 14 41/30 .045 1.14 1.100 27.94 7.5 710<br />
P11M4 20 14 41/30 .045 1.14 1.155 29.34 7.5 780<br />
P12M4 24 14 41/30 .045 1.14 1.260 32.00 6.7 985<br />
P13M4 28 14 41/30 .045 1.14 1.330 33.78 6.7 1080<br />
P14M4 30 14 41/30 .045 1.14 1.340 34.04 6.7 1130<br />
P15M4 37 14 41/30 .045 1.14 1.480 37.54 6 1330<br />
P16M4 5 12 65/30 .045 1.14 .710 18.03 16 330<br />
P17M4 6 12 65/30 .045 1.14 .740 18.80 16 360<br />
P18M4 7 12 65/30 .045 1.14 .770 19.56 14 415<br />
P19M4 8 12 65/30 .045 1.14 .825 20.96 14 470<br />
P20M4 9 12 65/30 .045 1.14 .900 22.86 14 515<br />
P21M4 10 12 65/30 .045 1.14 1.000 25.40 14 580<br />
P22M4 12 12 65/30 .045 1.14 1.010 25.65 10 650<br />
P23M4 14 12 65/30 .045 1.14 1.080 27.43 10 740<br />
P24M4 16 12 65/30 .045 1.14 1.135 28.83 10 835<br />
P25M4 18 12 65/30 .045 1.14 1.150 29.97 10 910<br />
P26M4 20 12 65/30 .045 1.14 1.170 30.48 10 990<br />
P27M4 24 12 65/30 .045 1.14 1.400 35.56 9 1240<br />
P28M4 26 12 65/30 .045 1.14 1.400 35.56 9 1270<br />
P29M4 27 12 65/30 .045 1.14 1.485 37.72 9 1310<br />
P30M4 28 12 65/30 .045 1.14 1.500 38.10 9 1345<br />
P31M4 30 12 65/30 .045 1.14 1.500 38.10 9 1415<br />
P32M4 36 12 65/30 .045 1.14 1.653 41.99 8 1670<br />
P33M4 40 12 65/30 .045 1.14 1.690 42.93 8 1830<br />
P34M4 44 12 65/30 .045 1.14 1.885 47.88 7 2000<br />
P35M4 50 12 65/30 .045 1.14 1.970 50.04 7 2300<br />
P36M4 5 10 104/30 .045 1.14 .770 19.56 20 465<br />
P37M4 6 10 104/30 .045 1.14 .875 22.23 20 500<br />
P38M4 8 10 104/30 .045 1.14 .940 23.88 17.5 625<br />
P39M4 10 10 104/30 .045 1.14 1.025 26.04 17.5 765<br />
P40M4 12 10 104/30 .045 1.14 1.140 28.96 12.5 865<br />
P41M4 16 10 104/30 .045 1.14 1.230 31.24 12.5 1150<br />
P42M4 20 10 104/30 .045 1.14 1.260 32.00 12.5 1445<br />
** Values shown are for current carrying conductors. A grounding conductor,<br />
or one which carries only the unbalanced current from other conductors,<br />
is NOT counted in determining current carrying capacity.