THE INTERNATIONAL CERTIFICATION NETWORK<br />

<strong>CP12120</strong><br />

<strong>12V</strong><strong>12Ah</strong><br />

Battery voltage(V)<br />

13.0<br />

12.0<br />

11.0<br />

10.0<br />

9.0<br />

8.0<br />

O<br />

Discharge characteristic (25 C)<br />

36A 24A 12A 8.14A<br />

0<br />

0 1 2 3 5 10 20 30 60 2 3 5 10 20 30<br />

min<br />

h<br />

Discharge time<br />

2.05A 0.6A<br />

3.12A 1.14A<br />

140<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

Charged<br />

Volume<br />

Current<br />

Voltage<br />

(%) (XCA) (V)<br />

0<br />

0.25<br />

0.20<br />

0.15<br />

0.10<br />

0.05<br />

0<br />

15.0<br />

14.0<br />

13.0<br />

12.0<br />

11.0<br />

Charge characteristic curve<br />

Constant voltage charge characteristic<br />

o<br />

(0.25CA,25 C)<br />

CHARGED VOLUME<br />

CHARGE VOLTAGE<br />

CHARGING CURRENT<br />

0 2 4 6 8 10 12 14 16 18 20<br />

Charging time (hours)<br />

(V/<strong>12V</strong>)<br />

(V/8V)<br />

(V/6V)<br />

Relationship between<br />

charging voltage and temperature<br />

(V/4V)<br />

(V/CELL)<br />

110<br />

100<br />

Self-discharge characteristic<br />

15.6<br />

15.0<br />

14.4<br />

10.4<br />

10.0<br />

9.6<br />

7.8<br />

7.5<br />

7.2<br />

5.2<br />

5.0<br />

4.8<br />

2.6<br />

2.5<br />

2.4<br />

CYCLE U S E<br />

Capacity(%)<br />

90<br />

80<br />

70<br />

13.8<br />

9.2<br />

6.9<br />

4.6<br />

2.3<br />

STAND BY USE<br />

60<br />

o<br />

40 C<br />

o<br />

30 C<br />

o<br />

20 C<br />

13.2<br />

8.8<br />

6.6<br />

4.4<br />

2.2<br />

50<br />

-10 0 10 20 30 40 50 60<br />

o<br />

Ambient temperature( C)<br />

40<br />

0 2 4 6 8 10 12 14 16 18 20<br />

Storage time: months<br />

120<br />

Life characteristics of standby use<br />

120<br />

Cycle service life in relation to<br />

depth of discharge<br />

100<br />

100<br />

Capacity(%)<br />

80<br />

60<br />

40<br />

Testing conditions: floating voltage: 2.27 to 2.30V/Cell<br />

o o<br />

ambient temperature: 25 C(77 F)<br />

Capacity(%)<br />

80<br />

60<br />

40<br />

100% D.O.D. 50% D.O.D. 30% Depth of discharge<br />

20<br />

20<br />

0<br />

0 1 2 3<br />

Life(year)<br />

0<br />

200 400 600 800 1000 1200 1400<br />

Number of cycles(cycles)<br />

10<br />

Temperature effects on float life<br />

120<br />

Temperature effects on capacity<br />

Life(years)<br />

1<br />

2.30V/Cell<br />

Capacity (%)<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0.05C<br />

0.1C<br />

0.2C<br />

01.C<br />

20C .<br />

30 . C<br />

0.1<br />

10 20 30 40 50 60<br />

o<br />

Temperature( C)<br />

0<br />

-20 -10 0 10 20 30 40 50<br />

o<br />

Temperature( C)<br />

ISO9001:2000<br />

MH25860<br />

G4M19906-9202-E-16<br />

Shenzhen Center Power Tech. Co., Ltd.<br />

Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China<br />

Tel: (+86-755) 8431 8088 Fax: (+86-755) 84318038<br />

E-mail: sales@vision-batt.com<br />

www.vision-batt.com<br />

Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2003-9)<br />

Page 2 of 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!