CP12120 12V 12Ah(20hr)
CP12120 12V 12Ah(20hr)
CP12120 12V 12Ah(20hr)
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
THE INTERNATIONAL CERTIFICATION NETWORK<br />
<strong>CP12120</strong><br />
<strong>12V</strong><strong>12Ah</strong><br />
Battery voltage(V)<br />
13.0<br />
12.0<br />
11.0<br />
10.0<br />
9.0<br />
8.0<br />
O<br />
Discharge characteristic (25 C)<br />
36A 24A 12A 8.14A<br />
0<br />
0 1 2 3 5 10 20 30 60 2 3 5 10 20 30<br />
min<br />
h<br />
Discharge time<br />
2.05A 0.6A<br />
3.12A 1.14A<br />
140<br />
120<br />
100<br />
80<br />
60<br />
40<br />
20<br />
Charged<br />
Volume<br />
Current<br />
Voltage<br />
(%) (XCA) (V)<br />
0<br />
0.25<br />
0.20<br />
0.15<br />
0.10<br />
0.05<br />
0<br />
15.0<br />
14.0<br />
13.0<br />
12.0<br />
11.0<br />
Charge characteristic curve<br />
Constant voltage charge characteristic<br />
o<br />
(0.25CA,25 C)<br />
CHARGED VOLUME<br />
CHARGE VOLTAGE<br />
CHARGING CURRENT<br />
0 2 4 6 8 10 12 14 16 18 20<br />
Charging time (hours)<br />
(V/<strong>12V</strong>)<br />
(V/8V)<br />
(V/6V)<br />
Relationship between<br />
charging voltage and temperature<br />
(V/4V)<br />
(V/CELL)<br />
110<br />
100<br />
Self-discharge characteristic<br />
15.6<br />
15.0<br />
14.4<br />
10.4<br />
10.0<br />
9.6<br />
7.8<br />
7.5<br />
7.2<br />
5.2<br />
5.0<br />
4.8<br />
2.6<br />
2.5<br />
2.4<br />
CYCLE U S E<br />
Capacity(%)<br />
90<br />
80<br />
70<br />
13.8<br />
9.2<br />
6.9<br />
4.6<br />
2.3<br />
STAND BY USE<br />
60<br />
o<br />
40 C<br />
o<br />
30 C<br />
o<br />
20 C<br />
13.2<br />
8.8<br />
6.6<br />
4.4<br />
2.2<br />
50<br />
-10 0 10 20 30 40 50 60<br />
o<br />
Ambient temperature( C)<br />
40<br />
0 2 4 6 8 10 12 14 16 18 20<br />
Storage time: months<br />
120<br />
Life characteristics of standby use<br />
120<br />
Cycle service life in relation to<br />
depth of discharge<br />
100<br />
100<br />
Capacity(%)<br />
80<br />
60<br />
40<br />
Testing conditions: floating voltage: 2.27 to 2.30V/Cell<br />
o o<br />
ambient temperature: 25 C(77 F)<br />
Capacity(%)<br />
80<br />
60<br />
40<br />
100% D.O.D. 50% D.O.D. 30% Depth of discharge<br />
20<br />
20<br />
0<br />
0 1 2 3<br />
Life(year)<br />
0<br />
200 400 600 800 1000 1200 1400<br />
Number of cycles(cycles)<br />
10<br />
Temperature effects on float life<br />
120<br />
Temperature effects on capacity<br />
Life(years)<br />
1<br />
2.30V/Cell<br />
Capacity (%)<br />
100<br />
80<br />
60<br />
40<br />
20<br />
0.05C<br />
0.1C<br />
0.2C<br />
01.C<br />
20C .<br />
30 . C<br />
0.1<br />
10 20 30 40 50 60<br />
o<br />
Temperature( C)<br />
0<br />
-20 -10 0 10 20 30 40 50<br />
o<br />
Temperature( C)<br />
ISO9001:2000<br />
MH25860<br />
G4M19906-9202-E-16<br />
Shenzhen Center Power Tech. Co., Ltd.<br />
Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China<br />
Tel: (+86-755) 8431 8088 Fax: (+86-755) 84318038<br />
E-mail: sales@vision-batt.com<br />
www.vision-batt.com<br />
Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2003-9)<br />
Page 2 of 2