Jabi<strong>the</strong>rm<br />

Rohrsysteme AG<br />

Brügger Str. 6<br />

53842 Troisdorf<br />

<strong>Spec</strong> <strong>DIP</strong> <strong>3006</strong>-<strong>97</strong> <strong>Ind</strong><br />

<strong>Pre</strong>-<strong>insulated</strong> <strong>piping</strong> <strong>must</strong> <strong>consists</strong> <strong>the</strong> <strong>of</strong><br />

components<br />

carrier pipe<br />

insulation material<br />

protecting jacket<br />

free pipes (electrical heated)<br />

Carrier pipe :<br />

Carrier pipe is designed according to client<br />

spec and could be:<br />

carbon steel<br />

stainless steel<br />

Plastic<br />

GRP<br />

HDPE<br />

Etc.<br />

Carrier pipe is delivered in normal stock<br />

length, not <strong>insulated</strong> app. 200 mm for<br />

welding purpose. For GFK <strong>piping</strong> free ends<br />

could be longer for fixing <strong>the</strong> welding<br />

machinery.<br />

02241 95350 �<br />

02241 47871 FAX<br />

Spez. <strong>DIP</strong> <strong>3006</strong>-<strong>97</strong> <strong>Ind</strong><br />

Vorisolierte Rohre bestehen aus folgenden<br />

Komponenten:<br />

Mediumrohr<br />

Isolationsmaterial<br />

Schutzmantel<br />

Leerrohr (elektrisch beheizt)<br />

Produktrohr :<br />

Das Produktrohr wird nach Kunden Norm<br />

ausgelegt und kann sein:<br />

C-Stahlrohr<br />

Edelstahlrohr<br />

Plastikrohr<br />

Gfk-Material<br />

HDPE<br />

u.s.w.<br />

Mediumrohre werden in Normlängen geliefert.<br />

Die freien Isolierenden betragen<br />

normalerweise ca. 200 mm, für GFK Rohre<br />

auch länger bei Verwendung einer<br />

Schweißmaschine.<br />

1


Jabi<strong>the</strong>rm<br />

Rohrsysteme AG<br />

Brügger Str. 6<br />

53842 Troisdorf<br />

Insulation material:<br />

Insulation <strong>must</strong> be <strong>of</strong> Polyurethane foam<br />

with a min. <strong>of</strong> 60-80 kg/m3 mean density.<br />

The foam <strong>must</strong> be HCFC/CFC-free CO2<br />

blown. Polyurethane <strong>must</strong> fix carrier pipe<br />

and protecting jacket to one unit with a<br />

min. tan bonding force <strong>of</strong> 0,08 MPa. In case<br />

<strong>of</strong> very smooth carrier pipe surfaces (e.g..<br />

PE) <strong>the</strong> value <strong>of</strong> 0,08 MPa could be lower.<br />

Foamed material <strong>must</strong> have a resistance <strong>of</strong><br />

deformation <strong>of</strong> less <strong>the</strong>n 10 % at 0,15 MPa.<br />

Heat conductivity is max 0,03 W/mK.<br />

The maximum temperature stability <strong>of</strong> <strong>the</strong><br />

PUR-foam is 140° C at a life time <strong>of</strong> 30<br />

years. The PUR-foam shall have a uniform<br />

cell structure. Voids and bubbles shall only<br />

occur in exception. Single void shall leave<br />

less <strong>the</strong>n 1/3 <strong>of</strong> <strong>the</strong> nominal insulation<br />

thickness. The closed cell content shall be<br />

less than 85 %. The structure/bonding force<br />

could be reduced in a thin boundary layer at<br />

<strong>the</strong> protecting jacket by using spirally<br />

wound <strong>piping</strong> out <strong>of</strong> rests <strong>of</strong> production.<br />

PUR-foam without fire protection additives<br />

shall have a maximum content <strong>of</strong> chlorides<br />

<strong>of</strong> 60 ppm.<br />

Centre line deviation<br />

The distance between <strong>the</strong> centerline <strong>of</strong> <strong>the</strong><br />

service pipe and <strong>the</strong> casing at any point shall not<br />

exceed <strong>the</strong> limits <strong>of</strong> <strong>the</strong> table below.<br />

Mantel mm<br />


Jabi<strong>the</strong>rm<br />

Rohrsysteme AG<br />

Brügger Str. 6<br />

53842 Troisdorf<br />

Protecting jacket :<br />

The protecting jacket <strong>must</strong> be spirally<br />

wound <strong>piping</strong> locked 4 times at <strong>the</strong> inside.<br />

Material shall be<br />

A) AlMg2Mn0,8 or AlMg3<br />

B) Stainless steel 1.4306<br />

C) Aluzink AZ185<br />

D) Galvanized steel<br />

E) HDPE (underground service)<br />

with a thickness <strong>of</strong> 0,8 mm (A,B) or 0,6<br />

mm (C,D). For cooling purposes <strong>the</strong><br />

locking joint could have an elastically inlet.<br />

At <strong>the</strong> jacket could be oil production leftovers.<br />

HDPE min. thickness see below<br />

Außen Wd<br />

75 2,2<br />

90 2,2<br />

110 2,5<br />

125 2,5<br />

140 3<br />

160 3<br />

180 3<br />

200 3,2<br />

225 3,5<br />

250 3,9<br />

280 4,4<br />

315 4,9<br />

355 5,6<br />

400 6,3<br />

450 7<br />

500 7,8<br />

560 8,8<br />

630 9,8<br />

710 11,1<br />

800 12,5<br />

02241 95350 �<br />

02241 47871 FAX<br />

Schutzrohr :<br />

Der 4-fache Wickelfalz ist auf der Innenseite<br />

angeordnet. Material kann sein:<br />

A) AlMg2Mn0,8 oder AlMg3<br />

B) Edelstahl 1.4306<br />

C) Aluzink AZ185<br />

D) verzinktes Blech<br />

E) HDPE (erdverlegt)<br />

mit einer Wanddicke von 0,8 mm (A,B) oder<br />

0,6 mm (C,D). Bei kaltgehenden Leitungen<br />

kann in der Falz des Außenmantels eine<br />

elastische Diffusionssperre eingebracht<br />

werden. Am Außenmantel können sich<br />

produktionsbedingt Reste vom Walzöl befinden.<br />

HDPE min. Wanddicke siehe unten<br />

Außen Wd<br />

75 2,2<br />

90 2,2<br />

110 2,5<br />

125 2,5<br />

140 3<br />

160 3<br />

180 3<br />

200 3,2<br />

225 3,5<br />

250 3,9<br />

280 4,4<br />

315 4,9<br />

355 5,6<br />

400 6,3<br />

450 7<br />

500 7,8<br />

560 8,8<br />

630 9,8<br />

710 11,1<br />

800 12,5<br />

3


Jabi<strong>the</strong>rm<br />

Rohrsysteme AG<br />

Brügger Str. 6<br />

53842 Troisdorf<br />

Free pipes (electrical heated)<br />

For electrical heated lines <strong>piping</strong> <strong>must</strong> have<br />

free pipes with a diameter<br />

(10x0,5 / 8x0,5 /oval 18x10x0,5) mm<br />

stainless steel 1.4301 fixed to <strong>the</strong> carrier<br />

pipe. The bonding material <strong>must</strong> have a<br />

resistance <strong>of</strong> 10 N/mm² for a maximum<br />

Temperature <strong>of</strong> 130° C (long running<br />

value) in fixing to <strong>the</strong> carrier pipe. Bonding<br />

material shall have a <strong>the</strong>rmal conductivity<br />

<strong>of</strong> app. 1 W/mK for a maximum Temperature<br />

<strong>of</strong> 130° C (long running value).<br />

Bonding material shall withstand 180° C<br />

for short time strain. The bonding material<br />

doesn’t have a corrosion influence to <strong>the</strong><br />

carrier pipe and has to be hydrolytic<br />

material.<br />

The free pipe has to be bonded completely<br />

to <strong>the</strong> carrier pipe to allow a complete heat<br />

flow. All electrical free pipes <strong>must</strong> be<br />

closed at <strong>the</strong> top. The end <strong>of</strong> <strong>the</strong> free pipe<br />

<strong>must</strong> be flared not to damage <strong>the</strong> heating<br />

cable at installation. The free pipes are not<br />

allowed to have joints into <strong>the</strong> prefabricated<br />

insulation. The free pipes end 50 mm in<br />

front <strong>of</strong> <strong>the</strong> insulation.<br />

02241 95350 �<br />

02241 47871 FAX<br />

Leerrohre (elektrisch beheizt)<br />

Bei elektrisch beheizten Produktrohrleitungen<br />

werden Edelstahl-Leerrohre aus<br />

1.4301 (10x0,5 / 8x0,5 /oval 18x10x0,5)<br />

mm kraftschlüssig und wärmeleitend am<br />

Produktrohr angebracht. Der Wärmeleitkleber<br />

soll eine Druck- und Scherfestigkeit<br />

von min. 10 N/mm² haben. Dieser Wert ist<br />

bis zu einer maximalen Temperaturbelastung<br />

(Langzeitwert) von 130° C einzuhalten.<br />

Kurzfristig kann der Kleber bis<br />

180° C belastet werden. Die Wärmeleitfähigkeit<br />

des Klebers beträgt ca. 1 W/mK.<br />

Der Kleber darf nicht hygroskopisch reagieren<br />

und keine korrosiven Einflüsse auf<br />

die Werkst<strong>of</strong>fe der Produktrohre bzw. Leerrohre<br />

ausüben. Die Leerrohre sind aufgedornt<br />

und entgratet um das Einführen der<br />

Heizkabel zu erleichtern und Beschädigungen<br />

zu vermeiden. Die Leerrohre dürfen<br />

im Bereich der werksseitig aufgebrachten<br />

Isolierung keinerlei Verbindungsstellen<br />

aufweisen. Die Leerrohre ragen beidseitig<br />

50 mm aus der Isolierung heraus und sind<br />

mit Stopfen zu verschließen.<br />

4


Jabi<strong>the</strong>rm<br />

Rohrsysteme AG<br />

Brügger Str. 6<br />

53842 Troisdorf<br />

Fittings<br />

Bends, joints, T-pieces are <strong>insulated</strong> on site<br />

according to local spec. Protecting jacket<br />

<strong>must</strong> be <strong>the</strong> same material as pre-<strong>insulated</strong><br />

<strong>piping</strong>. Insulation material is mineral wool<br />

according to local spec. or will be done<br />

with PUR-foaming on site.<br />

Protecting jacket is made out <strong>of</strong> bended<br />

plates. The longitudinal and round joints<br />

<strong>must</strong> be permanently elastically sealed<br />

against water.<br />

02241 95350 �<br />

02241 47871 FAX<br />

Verbindungsstücke<br />

Bögen, Muffen und T-Stücke werden konventionell<br />

mit Mineralfasermatten vor Ort<br />

nach Norm isoliert oder mit PUR-Schaum<br />

vor Ort ausgeschäumt.<br />

Das Material des Schutzbleches entspricht<br />

dem des vorisolierten Rohres. Die Rund-<br />

und Längsnähte sind gesickt und dauerelastisch<br />

wasserdicht zu versiegeln.<br />

5


Jabi<strong>the</strong>rm<br />

Rohrsysteme AG<br />

Brügger Str. 6<br />

53842 Troisdorf<br />

Mounting instruction<br />

The <strong>piping</strong> are stocked on wide studding<br />

(pipeend) or on wooden pallet (insulation).<br />

Piping is delivered in normal stock length.<br />

Insulation ends app. 200 mm at <strong>the</strong> end <strong>of</strong><br />

<strong>the</strong> carrier pipe.<br />

Adapting pieces are cut with a saw or a<br />

metal slitting machine. For welding purposes<br />

<strong>the</strong> insulation is cut app. 200 mm at<br />

<strong>the</strong> end <strong>of</strong> <strong>the</strong> carrier pipe.<br />

Bends, T-pieces and o<strong>the</strong>r inserts are made<br />

with not <strong>insulated</strong> carrier pipe. The insulation<br />

is normally made on site.<br />

The expanding tendency is <strong>the</strong> same as to<br />

not <strong>insulated</strong> <strong>piping</strong>.<br />

The supporting length is according to <strong>the</strong><br />

rules for not <strong>insulated</strong> <strong>piping</strong> to calculate.<br />

The weight <strong>of</strong> <strong>the</strong> insulation is carried by<br />

<strong>the</strong> protecting jacket.<br />

The supports are fixed at <strong>the</strong> outer casing.<br />

The whole system moves as one unit. The<br />

system manages <strong>the</strong> normal forces out <strong>of</strong><br />

<strong>the</strong> resistance <strong>of</strong> <strong>the</strong> sliding supports.<br />

Fix points are normally fixed to <strong>the</strong> carrier<br />

pipe but could also be fixing at <strong>the</strong> outer<br />

casing (<strong>must</strong> comply with max. bonding<br />

force).<br />

02241 95350 �<br />

02241 47871 FAX<br />

Montagehinweise<br />

Rohre werden auf breiten Kanthölzern (am<br />

Rohrende) oder Holz-Paletten (auf dem<br />

Isoliermantel) gelagert.<br />

Rohrlieferlängen sind Standardrohrlängen<br />

des Mediumrohres.<br />

Die Isolierenden betragen in der Regel ca.<br />

200 mm.<br />

Paßstücke werden mittels Trennscheibe<br />

oder Säge von den Lieferlängen abgeschnitten.<br />

Für die Verbindungstechnik wird<br />

die Isolierung nach Erfordernis abgetrennt.<br />

Bögen, T-Stücke oder andere Fittings<br />

werden in unisolierten Mediumrohr erstellt.<br />

Die Isolierung erfolgt in der Regel vor Ort.<br />

Das Ausdehnungsverhalten von vorisolierten<br />

Rohrleitungen entspricht dem von<br />

unisolierten Rohrleitungen.<br />

Bei der Berechnung von Stützweiten ist von<br />

den Berechnungsregeln für unisolierte<br />

Rohrleitungen auszugehen, das Isoliergewicht<br />

wird durch den Wickelfalzmantel<br />

getragen.<br />

Halterungen werden am Außenmantel befestigt.<br />

Der gesamte Isolierverbund bewegt<br />

sich als Einheit und ist in der Lage die<br />

üblichen Kräfte zu übertragen.<br />

Festpunkte werden in der Regel am<br />

Mediumrohr befestigt, können jedoch auch<br />

bei Einhaltung der angegebenen<br />

Scherkräfte am Außenmantel befestigt<br />

werden.<br />

04/04<br />

6