PARCEL 17, PARCEL SPECIFIC REGULATIONS<br />

SCHEDULEZB 17 lp.1or2<br />

PARCEL DESGRIPTION:<br />

KEY PLAN:<br />

Maximum Lot Area: 6661m'?<br />

Permitted Development:<br />

Parcel 17 is intended to be developed with<br />

Overlapping Townhouses with two separate<br />

Buildlngs <strong>of</strong> twelve to sixteen units each. Covered<br />

Parking will be located below each Building and<br />

accessed at the rear <strong>of</strong> the Buildings via a driveway.<br />

Pedestrians will exit the parking and access the units<br />

via the street. Allthe Buildings shall be constructed<br />

within the Building Envelope and Height established<br />

in the Parcel Specific Regulations in this Schedule<br />

and illustrated in drawings A, B & C on Page 2 <strong>of</strong> this<br />

Schedule.<br />

PARCEL SPECIFIG REGULATIONS:<br />

SETBACKS:<br />

1. The minimum Front Yard Setback shall be 4m.<br />

2.The maximum Front Yard Setback shall be 6m.<br />

3. The minimum Side Yard Setback shall be 3m.<br />

4. The minimum Rear Yard Setback shall be 8m.<br />

SITE COVERAGE & GROSS FLOOR AREA:<br />

5. The maximum Site Coverage shall be 28o/o.<br />

6. The maximum Gross Floor Area shall be 5016m'?.<br />

UNITS:<br />

7. The maximum number <strong>of</strong> Primary Dwelling Units shall be 34.<br />

8. The minimum number <strong>of</strong> Primary Dwelling Units shall be 26.<br />

STREET FRONTAGES:<br />

g. The Building Frontage <strong>of</strong> a Building shall not be greater than 54m without being intemlpted by an Undeveloped<br />

View Gorridor <strong>of</strong> a minimum <strong>of</strong> 12m wide.<br />

10. The total Bullding Frontage shall not be less than 65% <strong>of</strong> the Frontage, and the Bullding shall be constructed<br />

such that 65% <strong>of</strong> the Building Frontage is constructed to the minimum Front Yard Setback.<br />

HEIGHT:<br />

11. For the purpose <strong>of</strong> measuring Height, the Facing Street shall be Road 6.<br />

12. The maximum Height on the Parcel shall be 3 Habitable Floors or 12m, whichever is less.<br />