Advance 2007 Atlas - Electronic Ballasts Section - SW Electric ...
Advance 2007 Atlas - Electronic Ballasts Section - SW Electric ...
Advance 2007 Atlas - Electronic Ballasts Section - SW Electric ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
ELECTRONIC<br />
FLUORESCENT<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Contents<br />
General Information .............................................................. 1-2 to 1-25<br />
Compact Fluorescent Lamps ..............................................1-26 to 1-39<br />
CFL<br />
PLH<br />
Long Twin Tubes<br />
2D<br />
Linear Fluorescent Lamps ..................................................1-40 to 1-69<br />
T5<br />
T5 and T5/HO Cirline<br />
T5/HO<br />
T8<br />
T8 Slimline<br />
T8/HO<br />
T10 and T12<br />
T12 Slimline<br />
T12/HO<br />
ELECTRONIC<br />
FLUORESCENT<br />
Note:<br />
Refer to pages 8-14 to 8-30 for Ballast Specifications<br />
Corporate Offices<br />
(800) 322-2086<br />
Customer Support/Technical Service<br />
(800) 372-3331 • (+) 1 847 390-5000 (International)<br />
Visit our web site at www.advancetransformer.com<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-1
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - Standard <strong>Electronic</strong><br />
ELECTRONIC<br />
FLUORESCENT<br />
For T8 and T12 Instant or Rapid Start Fluorescent Lamps and for 39 Watt, 40 Watt,<br />
and 50 Watt T5 Rapid Start Long Twin Tube Lamps<br />
Reliable and energy-efficient, <strong>Advance</strong>'s broad line of standard electronic ballasts for T8, T12,<br />
and T5 fluorescent lamps offers proven performance and fast payback of investment based on the<br />
up to 40% energy savings they drive relative to standard magnetic ballast models. A widely popular<br />
product that also qualifies for rebates by a host of utility demand-side management programs<br />
nationwide, <strong>Advance</strong>'s line of standard electronic ballasts are ideal for a broad range of commercial<br />
retrofit and new construction applications.<br />
<strong>Advance</strong>'s standard electronic ballasts are ideal for general office applications as well as<br />
conference, meeting, and board rooms.<br />
Features<br />
Energy-efficient design<br />
Operates up to 75% quieter than<br />
conventional magnetic ballasts<br />
High frequency operation<br />
Fits the exact footprint of the magnetic<br />
ballasts they replace<br />
Backed by 5-year warranty<br />
Benefits<br />
Reduces lighting costs by up to 20% when installed<br />
with modern, energy-efficient lamps in building retrofits<br />
Enhances design flexibility and user satisfaction<br />
Delivers flicker-free operation<br />
Enhances ease of installation in retrofit applications<br />
Insures customer security and satisfaction<br />
1-2<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - Centium ®<br />
Standard or Small Can for T8 and T12 Instant or Rapid Start Fluorescent Lamps<br />
and Micro Can for T8 and T5 Instant Start Fluorescent Lamps<br />
Reliable and energy-efficient, <strong>Advance</strong>'s broad line of Centium high frequency electronic ballasts<br />
for T8 and T12 fluorescent lamps offers all of the energy-saving properties of <strong>Advance</strong>'s standard<br />
electronic line plus the added benefits of extended life and small can size options for enhanced<br />
flexibility and versatility. Possessing the same wiring configuration and mounting dimensions as<br />
standard size ballasts, <strong>Advance</strong>'s Centium line is an optimal choice for a broad range of new construction<br />
and retrofit applications within the commercial sector.<br />
ELECTRONIC<br />
FLUORESCENT<br />
Centium is ideal for general office lighting, conference, meeting, and board room applications,<br />
indirect and decorative lighting, and new fixture designs requiring smaller ballasts.<br />
Features<br />
Energy-efficient design<br />
Many instant start models feature IntelliVolt<br />
multiple-voltage technology (enabling<br />
operation from 120 to 277 volts, 50/60Hz<br />
with sustained variation of +/-10%)<br />
Specialized electronic circuitry<br />
High frequency operation<br />
Backed by 5-year warranty<br />
Benefits<br />
Reduces lighting costs by up to 20% when installed<br />
with modern, energy-efficient lamps in building retrofits<br />
Enhances accuracy of ordering and reduces SKU<br />
requirements<br />
Optimizes fit for applications where long lamp life or<br />
frequent switching is required<br />
Provides silent, flicker-free operation<br />
Insures customer security and satisfaction<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-3
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - Optanium ®<br />
High-efficiency electronic ballasts for a broad range of T5 and T8 lighting systems<br />
ELECTRONIC<br />
FLUORESCENT<br />
Versatile and high-performing, <strong>Advance</strong>'s Optanium ® high-efficiency electronic ballasts optimize<br />
energy savings and are compatible with T5 high efficiency lamps and the market's wide variety of<br />
T8 fluorescent lamp options -- from standard 32-watt, 40-watt, 25-watt, and 17-watt lamps to 4-<br />
foot energy-saving 30-watt, 28-watt, and 25-watt models -- delivering maximum flexibility and<br />
freedom of choice. Offered in both instant start as well as programmed start options and in<br />
Generation 1.0 (dedicated voltage) and Generation 2.0 (incorporating True Performance<br />
Technology SM and IntelliVolt ® multiple voltage technology) versions.<br />
<strong>Advance</strong>'s Optanium family optimizes lumen-per-watt performance and delivers a high-efficiency<br />
solution for a broad range of commercial, industrial, and institutional applications.<br />
Features<br />
True Performance Technology SM (TPT)<br />
Available in Instant Start and Programmed Start<br />
models to support the market's broad range of<br />
high-efficiency T8 lamp applications<br />
Benefits<br />
<strong>Advance</strong>'s exclusive technology of engineered components<br />
optimizes T8 system performance, resulting in maximum<br />
energy savings, highest lumens-per-watt, and lowest cost of<br />
system ownership<br />
Maximizes flexibility and freedom of choice, regardless of<br />
whether the application involves long burn hours (IS),<br />
frequent switching (PS), or use with occupancy sensors<br />
and/or in frequent on/off areas (PS)<br />
Anti-striation circuitry<br />
Lamp auto-restrike circuitry (Instant Start<br />
Only) and anti-arcing technology<br />
Cold-start capability down to -20°F (on<br />
Optanium 2.0 Instant Start models operating<br />
32-watt lamps only)<br />
PLUS 90 Protection ®<br />
Reduces lamp striation typically seen in energy saving lamps<br />
These and other standard features within the Optanium 2.0<br />
line reduce maintenance concerns and enhance safety<br />
Delivers reliable performance in a wide range of extreme<br />
conditions<br />
<strong>Advance</strong>'s exclusive extended system warranty protection,<br />
which matches any lamp manufacturer's published lampballast<br />
system warranty, plus adds 90 days of additional<br />
warranty protection—on both the lamp and ballast!<br />
1-4<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - Mark 5<br />
Programmed Start Integrated Circuit <strong>Electronic</strong> Ballast for 1, 2, and 3 32-Watt,<br />
25-Watt, and 17-Watt T8 Fluorescent Lamps<br />
Designed for easy installation in new construction and retrofit settings, <strong>Advance</strong>'s new and<br />
improved Mark 5 Programmed Start ballasts for 1, 2, and 3 32-Watt, 25-Watt, and 17-Watt T8<br />
fluorescent lamps offer a wide range of features for specialized lighting applications. The Mark 5's<br />
unique integrated circuit-based control technology monitors lamp and ballast conditions to insure<br />
optimum lighting system performance.<br />
ELECTRONIC<br />
FLUORESCENT<br />
Mark 5 is ideal for a wide variety of new construction and retrofit applications.<br />
Features<br />
Programmed start technology<br />
Total harmonic distortion (THD) below<br />
10% for all lamp combinations in any<br />
application<br />
Custom integrated circuit monitors lamp<br />
and ballast conditions<br />
IntelliVolt ® multiple-voltage technology<br />
(enabling Mark 5's operation at any input<br />
voltage from 90 to 305 volts, 50/60Hz)<br />
Operation above 42 Khz<br />
Benefits<br />
Provides extended lamp life in frequent switching<br />
applications (up to 50,000 starts)<br />
Reduces potential for neutral and line conductor<br />
overheating<br />
Delivers optimal lighting system performance<br />
Enhances accuracy of ordering and reduces SKU<br />
requirements<br />
Reduces potential interference with infrared remote<br />
control systems<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-5
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - SmartMate ®<br />
<strong>Electronic</strong> <strong>Ballasts</strong> for 4-Pin Compact Fluorescent Lamps<br />
ELECTRONIC<br />
FLUORESCENT<br />
Offering maximum versatility, <strong>Advance</strong>'s SmartMate electronic ballasts for 4-pin compact fluorescent<br />
lamps drive a broad range of quad and triple-tube, circline, 2D, and long twin-tube lamps.<br />
Representing an innovative breakthrough in CFL ballast technology, SmartMate's energy-efficient<br />
design, compact and lightweight housing, and user-friendly features make SmartMate an ideal<br />
choice for fixture manufacturers, retrofitters, and MRO replacement.<br />
SmartMate is ideal in such applications as restaurants, reception areas, conference and meeting<br />
rooms, hotel and convention center ballrooms, and houses of worship, as well as in place of<br />
incandescent down-lighting systems.<br />
Features<br />
Color-coded dual-entry connector<br />
Color coded, poke-in terminals<br />
Quik Start models available which start<br />
lamps
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - Matchbox<br />
Miniaturized <strong>Electronic</strong> <strong>Ballasts</strong> for 4-pin Compact Fluorescent and T5 Linear Lamps<br />
Packaged in a lightweight, miniature housing relative to standard ballast products, <strong>Advance</strong>'s 120V<br />
Matchbox line of energy-efficient electronic ballasts for T5 linear (8-14W) and 4-Pin Compact<br />
Fluorescent (7-26W) lamps offer the combined benefits of enhanced design flexibility and significant<br />
energy savings (up to 25% energy savings compared to electromagnetic ballasts and up to<br />
75% savings over incandescent systems).<br />
ELECTRONIC<br />
FLUORESCENT<br />
Matchbox is ideal in undercabinet, task, ambient, and sign lighting applications as well as in halls<br />
and staircases. Matchbox ballasts meet the Energy Star residential ballast requirements.<br />
Features<br />
Instant-on feature<br />
Color-coded, poke-in-connectors<br />
<strong>Electronic</strong> design<br />
Class B FCC EMI Rating meets Energy Star<br />
and consumer EMI requirements<br />
End-of-lamp-life protection<br />
Benefits<br />
Provides flicker-free starting<br />
Enhances wiring accuracy and ease of<br />
assembly/installation<br />
Delivers energy savings, low temperature starting<br />
(0° F), improved lamp life over 2-pin models, and<br />
no audible noise<br />
Insures approval for use in residential applications<br />
Safely removes power to the lamp(s)<br />
Note; Matchbox ballasts are part of the AmbiStar family<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-7
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - AmbiStar <br />
<strong>Electronic</strong> <strong>Ballasts</strong> for 4-pin Compact Fluorescent and T5, T8 or T12 Linear Lamps<br />
ELECTRONIC<br />
FLUORESCENT<br />
<strong>Advance</strong>'s family of electronic ballasts specifically designed for popular fluorescent applications<br />
in homes and other non-commercial environments brings all of the energy-efficient benefits of<br />
fluorescent lighting to residential and hospitality applications. FCC Class B EMI compliant and<br />
available for T5 linear (8-14W), T8 linear (17-32W), T12 linear (34W-40W) and 4-pin CFL lamps.<br />
<strong>Advance</strong>'s AmbiStar ballasts are compact and lightweight, provide quick starting and save users<br />
significant energy costs relative to alternative lighting sources.<br />
Features<br />
Less than 1.0 second starting<br />
<strong>Electronic</strong> design<br />
Class B FCC EMI Rating meets Energy Star<br />
and consumer EMI requirements<br />
End-of-lamp-life protection for T5 lamps<br />
and smaller<br />
Benefits<br />
Provides flicker-free starting<br />
Increased energy savings over incandescent and<br />
fluorescent magnetic with no audible noise<br />
Insures approval in residential applications<br />
Safely removes power to the lamp(s)<br />
1-8<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - PowrKut ®<br />
Low Frequency <strong>Electronic</strong> <strong>Ballasts</strong> for T8, T10, and T12 Rapid Start Fluorescent Lamps<br />
<strong>Advance</strong>'s PowrKut low frequency electronic ballasts combine the proven performance of electromagnetic<br />
circuitry with the energy savings capabilities of electronics to provide a cost-effective,<br />
energy-efficient solution that offers maximum protection against electromagnetic and radio frequency<br />
interference (EMI/RFI).<br />
ELECTRONIC<br />
FLUORESCENT<br />
<strong>Advance</strong>'s PowrKut ballast is ideal in such applications as office spaces at industrial sites, health<br />
care facilities, consumer electronics retail stores, libraries, educational institutions, radio and<br />
television studios, and in any settings where EMI and/or RFI are a concern.<br />
Features<br />
Unique PowrKut design<br />
Hybrid design with core & coil input<br />
Ability to operate lamps at 60Hz<br />
Open mounting distance for remote or<br />
tandem wiring<br />
Operates T8, T10, and T12 standard and<br />
energy-savings lamps<br />
Benefits<br />
Delivers up to a 26% reduction in energy costs<br />
compared to "standard" electromagnetic ballasts<br />
Protects against transients or voltage surges.<br />
Compatible with powerline carrier systems<br />
Eliminates possible interference with infrared<br />
control systems, radio or television reception, or<br />
portable phone transmission<br />
Provides greater flexibility relative to installation<br />
<strong>Ballasts</strong> are available for more than 90% of<br />
fluorescent applications in the market<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-9
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
ELECTRONIC<br />
FLUORESCENT<br />
<strong>Electronic</strong> Ballast Fundamentals<br />
The job of a ballast<br />
In all fluorescent lighting systems, the ballast’s basic tasks<br />
include:<br />
• Providing the proper voltage to establish an arc between the<br />
two electrodes.<br />
• Regulating the electric current flowing through the lamp to<br />
stabilize light output.<br />
In some fluorescent lighting systems, the ballast also provides<br />
a controlled amount of electrical energy to preheat or maintain the<br />
temperature of the lamp electrodes at levels specified by the manufacturer.<br />
This is required to prevent electrode filaments deteriorating<br />
prematurely and shortening the lamp life.<br />
Starting Methods<br />
For many years there were only three types of lighting systems:<br />
preheat, rapid start and slimline instant start. With the introduction<br />
of electronic ballasts, two additional types of lighting system circuits<br />
have been added: instant start for T8 lamps and programmed<br />
start. Each requires a special ballast design to operate the lamps<br />
in the circuit properly.<br />
Instant start electronic ballasts start lamps without delay (
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Power Factor (PF) is the measurement of how effectively a<br />
ballast converts the voltage and current supplied by the power<br />
source into watts of usable power delivered to the ballast and lamps.<br />
Perfect power utilization would result in a power factor of one.<br />
Input Watts<br />
PF =<br />
Input Current x Input Voltage<br />
A ballast’s power factor may be classified under any one<br />
of the following categories:<br />
High Power Factor (HPF) 0.90 or greater<br />
Power Factor Corrected (PFC) 0.80 to 0.89<br />
Normal (Low) Power Factor (NPF) 0.79 or less<br />
Power factor measurements pertain only to the effective use of<br />
power supplied to the ballast. They are not an indication of the<br />
ballast’s ability to supply light through the lamps. Because low<br />
power factor ballasts require about twice the current needed by<br />
high power factor ballasts, they allow fewer fixtures per circuit and<br />
create added wiring costs. High power factor ballasts are generally<br />
specified for all commercial lighting applications.<br />
EMI/RFI. Because they operate at high frequency, electronic<br />
ballasts may produce electromagnetic interference (EMI) or radio<br />
frequency interference (RFI). RFI frequencies are a subset of EMI<br />
frequencies. EMI issues cover all possible operating frequencies<br />
while RFI is only concerned with radio and television frequencies.<br />
This interference could affect the operation of sensitive electrical<br />
equipment, such as radios, televisions or medical equipment. All<br />
<strong>Advance</strong> electronic ballasts incorporate features necessary<br />
to afford maximum protection for the operating environment and<br />
operate well within regulatory limits. For more information, see<br />
“The ABC’s of <strong>Electronic</strong> Fluorescent <strong>Ballasts</strong>”.<br />
Ballast Noise. The slight “humming” sound associated with<br />
fluorescent lighting systems results from vibration caused by the<br />
inherent electromagnetic action in the core-and-coil assembly of<br />
the ballasts. All electromagnetic and some electronic ballasts make<br />
this sound. <strong>Ballasts</strong> are assigned a sound rating, “A” through “F”,<br />
based on the amount of sound produced, with “A” being the<br />
quietest. Generally, the larger the lamp and ballast, the higher the<br />
sound level and the sound rating will be. Because electronic<br />
ballasts have smaller components, they have the lowest sound<br />
rating. Some electronic ballasts make almost no sound. There is<br />
no ANSI standard for this rating and it is left up to the manufacturer<br />
to rate their ballasts.<br />
Inrush Current. All electrical devices including ballasts have<br />
an initial current surge that is greater than their steady-state<br />
operating current. A new standard published by the National<br />
<strong>Electric</strong>al Manufacturers Association (NEMA) – NEMA 410 –<br />
Performance Testing for Lighting Controls and Switching Devices<br />
with <strong>Electronic</strong> Fluorescent <strong>Ballasts</strong> – covers worst-case ballast<br />
inrush currents. All circuit breakers and light switches are<br />
designed for inrush currents. The electrical system should be<br />
designed with this issue in mind.<br />
Total Harmonic Distortion (THD). Harmonic distortion occurs<br />
when the wave-shape of current or voltage varies from a pure sine<br />
wave. Except for a simple resistor, all electronic devices, including<br />
electromagnetic and electronic ballasts, contribute to power-line<br />
distortion. For ballasts, THD is generally considered the percent<br />
of harmonic current the ballast adds to the power distribution<br />
system. The ANSI standard for electronic ballasts specifies a<br />
maximum THD of 32%. However, most electric utilities now<br />
require that the THD of electronic ballasts be 20% or less. Almost<br />
all <strong>Advance</strong> electronic ballasts are rated for either less than<br />
20% THD or less than 10% THD.<br />
60 Hz Sine<br />
Wave<br />
Actual Waveform<br />
Third Harmonic<br />
(180Hz)<br />
Non-Dimming Applications<br />
Phase A<br />
Phase B<br />
Low Current<br />
Neutral Wire If low Third Harmonic<br />
on balanced system<br />
Phase C<br />
100% Plus Current<br />
Neutral Wire<br />
(Overheated)<br />
Phase A<br />
Phase B<br />
Third<br />
Harmonic<br />
Phase C<br />
When selecting a ballast for a lighting application, the Total<br />
Harmonic Current (THC) rating of the ballast is more significant<br />
than Total Harmonic Distortion (THD). This is because the absolute<br />
value of harmonic current, not the percentage, affects the electrical<br />
power distribution system. As can been seen in the table on page<br />
1-12, the THC rating of our Standard 2-lamp electronic T8 lamp<br />
ballast is well below that of both the conventional and energysaving<br />
magnetic T12 lamp ballasts it replaces. Moreover, the THC<br />
rating of our Centium electronic ballast is even lower.<br />
Dimming Applications<br />
Mark 7 ® 0-10V and ROVR<br />
Traditional low voltage controlled ballasts and ROVR TM typically<br />
produce less than 10% THD at full light output and less than<br />
20% THD throughout the entire dimming range, but require extra<br />
wires for the control circuit. THC is always lower than that of the<br />
conventional or energy-saving magnetic system.<br />
ELECTRONIC<br />
FLUORESCENT<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-11
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
ELECTRONIC<br />
FLUORESCENT<br />
Mark 10 ® Powerline<br />
Mark 10 ® Powerline electronic dimming ballasts are controlled<br />
by 2-wire modified powerline phase-cut style line voltage<br />
dimmers. Whenever the ballast is dimmed, the input voltage is<br />
cut or “chopped”, causing the THD and THC to increase and the<br />
Power Factor to decrease.<br />
Mark 10 ® Powerline electronic dimming systems (ballast and<br />
controller) have similar THD and Power Factor levels as the conventional<br />
lighting systems they replace. Since a much smaller load<br />
is required by the Mark 10 ® Powerline electronic dimming system<br />
to achieve the same illumination level as a magnetic ballast system<br />
(20-30% less), the total input current will be considerably less. As<br />
a result, the magnitude of the total harmonic current will be less.<br />
For example, a typical Mark 10 ® Powerline electronic ballast<br />
and dimmer control might draw a line current of 0.58A at 15%<br />
THD at full light output. If the light level is reduced to 5% of the<br />
maximum, the input power is decreased to 0.19A at 95% THD.<br />
While the THD level may seem alarmingly high at the 5% maximum<br />
light output setting, the total harmonic current is still<br />
lower (0.13A) than the conventional T12 magnetic system<br />
(0.20A). Moreover, the overall heating effect on the wires and<br />
the distribution transformer is never higher than the existing<br />
conventional or energy saving T12 magnetic systems. 1<br />
Conclusions<br />
Our analysis demonstrates that a simple ballast retrofit to<br />
electronic ballasts will not cause harmonic problems if none<br />
existed before the retrofit. Also, in new fixture applications, total<br />
harmonic distortion should not be a concern when specifying<br />
electronic ballasts. Finally, it is important to remember that electronic<br />
ballasts are not the greatest source of THD in an electrical<br />
distribution system. Other electronic devices such as computers,<br />
laser printers, and other electronic equipment can draw<br />
current with more than 100% THD in some cases.<br />
Table 1: Comparison of THD and THC Levels<br />
<strong>Advance</strong><br />
Part No.<br />
Ballast<br />
Type<br />
Light Output<br />
Setting<br />
Lamp<br />
Type<br />
Input<br />
Current<br />
% THD %THC 2<br />
RQM-2S40-TP<br />
Conventional<br />
Magnetic<br />
100% (Ballast<br />
Factor is 0.98)<br />
(2) F40T12 0.84A
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Ballast Life<br />
<strong>Advance</strong> fluorescent electronic and magnetic ballasts are<br />
designed and manufactured to engineering standards correlating to<br />
an average life expectancy of 50,000 hours of operation at maximum<br />
rated case temperature. Since <strong>Advance</strong> ballasts operate<br />
below their maximum case temperature in the majority of applications,<br />
increased ballast life can be expected. As a rule of thumb,<br />
ballast life is doubled for every 10°C reduction in ballast case<br />
operating temperature. However, there are many variables, such as<br />
input voltage, ambient temperature, etc. which affect ballast<br />
operating temperatures, and therefore ballast life.<br />
Lamp Operating Frequency<br />
Electromagnetic ballasts and the lamps connected to them operate<br />
at an input voltage frequency of 60 Hertz (Hz), 60 cycles per<br />
second–which is the standard alternating voltage/current frequency<br />
provided in North America. <strong>Electronic</strong> ballasts, on the other hand,<br />
convert this 60 Hz input to operate lamps at much higher<br />
frequencies above 20 Kilohertz (kHz), 20,000 cycles per second.<br />
<strong>Advance</strong> designs operate above 20 kHz, but avoid certain ranges<br />
such as 30-40 kHz (infrared) and 54-62 kHz (theft deterrent<br />
systems) due to interference issues.<br />
Because electronic ballasts function at high frequency, the fluorescent<br />
lighting systems that they operate can convert power to light<br />
more efficiently than systems operated by electromagnetic ballasts<br />
(See Chart Below). For example, lamps operated on electronic<br />
ballasts can produce over 10 percent more light then if operated on<br />
electromagnetic ballasts at the same power levels. In effect, today’s<br />
electronic ballasts provide additional energy savings by matching<br />
the light output from electromagnetic ballasts while operating the<br />
lamps at lower power. This is the main reason why electronic ballast<br />
systems are more efficient than magnetic ballast system.<br />
Light Output Percentage<br />
114<br />
112<br />
110<br />
108<br />
106<br />
104<br />
102<br />
100<br />
100Hz 1kHz 10kHz 100kHz<br />
Excitation Frequency<br />
Crest Factor<br />
Lamp manufacturers use crest factor to determine ballast<br />
performance as it relates to lamp life. Lamp Current Crest Factor<br />
is a measurement of current supplied by a ballast to start and<br />
operate the lamp. It is basically the ratio of peak current to RMS<br />
(average) current. High crest factor currents may cause the lamp<br />
electrodes to wear out faster, reducing lamp life. Crest factor<br />
requirements are regulated by ANSI (American National Standards<br />
Institute) standards and specified by lamp manufacturers. For<br />
rapid start and instant start T8 lamps the ratio is 1.7 maximum,<br />
and for instant start slimline lamps, it is 1.85 maximum.<br />
Weight and Size Advantages<br />
Since electronic components in electronic ballasts are smaller<br />
and lighter than the core-and-coil assembly in electromagnetic<br />
ballasts, electronic ballasts can weigh less than half as much as<br />
comparable electromagnetic models. Almost all <strong>Advance</strong> electronic<br />
ballasts have a smaller cross-section than electromagnetic ballasts<br />
but maintain the same mounting dimensions. This means that they<br />
can fit into all new fixture designs and can be easily retrofitted into<br />
existing fluorescent lighting systems.<br />
Controllability<br />
The ability of a building’s occupants to control how they light<br />
their space is becoming an increasingly important factor for<br />
organizations in determining what real estate they will lease,<br />
buy or invest in. The ability to dim the lights or easily shut them<br />
off completely is a trend fueled not just by a desire to help the environment,<br />
but also by significant economic benefits. These benefits<br />
include greater energy efficiency – in terms of reduced HVAC costs<br />
as well as energy savings for lighting – more comfortable and<br />
productive working environments, and compliance with ever tighter<br />
energy efficiency regulations. <strong>Advance</strong> offers three families of<br />
electronic controllable ballasts – ROVR , Mark 7 0-10V and<br />
Mark 10 Powerline – that can provide up to 65% energy savings<br />
over standard T8 fixed light output systems.<br />
Compatibility With Powerline Carrier Systems<br />
A powerline carrier system (PLC) uses electronic wiring devices<br />
to send information via a high frequency signal over the 120V or<br />
277V electrical power distribution system of a building. For example,<br />
PLC systems are used in automatic clock systems (master<br />
time systems) to synchronize all of the clocks in a building or reset<br />
the time after a power outage. They eliminate the need for maintenance<br />
personnel to reset hundreds of clocks throughout a facility.<br />
In a PLC system, a generator is used to impose a 1 to 4V high<br />
frequency signal on top of the existing voltage sine wave (60 Hz).<br />
This signal is generally in the 2500 to 9500Hz range, with some<br />
older systems operating at 19,500Hz or higher. Some electronic<br />
ballasts which are capacitive can absorb the signal from a PLC<br />
system. As a result, the signal becomes too weak to be “heard” by<br />
the receiver (like a timeclock) connected to the powerline.<br />
Instant Start vs. Rapid Start Sockets for Dimming<br />
When using dimming ballasts in fixtures, sockets must be of the<br />
RAPID START type. Many fixtures with T-8 Instant Start electronic<br />
ballasts use jumpered or “shunted” Instant Start sockets.<br />
Controllable ballasts require two distinctly separate wires for each<br />
lamp socket. If you encounter shunted or jumpered sockets in a<br />
retrofit application, they must be removed and replaced with Rapid<br />
Start sockets.<br />
Improper socket application will damage the ballast and void the ballast warranty.<br />
Refer to ballast wiring diagram for proper installation.<br />
Rapid Start Sockets<br />
Shunted<br />
SHUNT<br />
Instant Start Sockets<br />
Jumpered<br />
ELECTRONIC<br />
FLUORESCENT<br />
I<br />
Peak<br />
I<br />
Peak<br />
Crest Factor =<br />
I<br />
R.M.S.<br />
I<br />
R.M.S.<br />
Color<br />
‘A’<br />
YES<br />
Color<br />
‘A’<br />
Color<br />
‘A’<br />
NO<br />
Color<br />
‘A’<br />
Fluorescent Lamp Burn-In<br />
Today, most lamp manufacturers do not require the burn-in of linear<br />
fluorescent lamps prior to dimming in order to attain rated lamp<br />
life and stable electrical measurements. However, some manufacturers<br />
compact fluorescent lamp sources do require a 100 hour<br />
burn-in prior to dimming. Consult your lamp manufacturer for their<br />
latest requirements.<br />
NO<br />
NO<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-13
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
ELECTRONIC<br />
FLUORESCENT<br />
ORDERING INFORMATION<br />
How to Order<br />
<strong>Advance</strong> Transformer has developed the industry’s broadest distribution system for<br />
electronic ballasts. More than 3000 stocking distributors nationwide. For information on<br />
the distributor best able to serve your needs, please call 800-372-3331.<br />
<strong>Electronic</strong> Ballast Part Number Breakdown<br />
I CF – 2 S 26 – H1 – LD<br />
CFL Mounting/Connector Options<br />
BS = Bottom mounting studs with single<br />
entry color coded connectors<br />
LD = Length mounting feet with SmartMate<br />
dual entry color coded connectors<br />
LS = Length mounting feet with single<br />
entry color coded connectors<br />
QS = QuikStart<br />
Corporate Offices<br />
(800) 322-2086<br />
Visit our web site at<br />
www.advancetransformer.com<br />
Customer Support/<br />
Technical Service<br />
(800) 372-3331<br />
+1 (847) 390-5000 (International)<br />
Linear Fluorescent Mounting/Connector Options<br />
TP* = Thermal Protected<br />
2LS = 2 Level Switching<br />
CFL Can Desription<br />
H1 = Hybrid metal / plastic case, size 1<br />
L2 = Linear<br />
M1 = Metal case, size 1<br />
M2 = Metal case, size 2<br />
M3 = Metal case, size 3<br />
M4 = Metal case, size 4<br />
M5 = Metal case, size 5<br />
S1 = Square, style 1<br />
S2 = Square, style 2<br />
SC = Small can<br />
Linear Fluorescent Can Desription<br />
90C = 90˚C maximum case temperature rating<br />
D = ‘D’ can<br />
G = ‘G’ can<br />
HL = High light output<br />
LW = Low watt<br />
MC = Micro can<br />
RH* = Reduced harmonics<br />
S = Slimline<br />
SC = Small can<br />
Lamp Watts (Primary lamp)<br />
Maximum Number of Lamps<br />
Family Name<br />
CF = Compact Fluorescent<br />
CN = Centium<br />
DA = ROVR<br />
DL = ROVR<br />
EL = Standard<br />
EZ = Mark 10 ® Powerline<br />
IC = Mark 5 ®<br />
MB = Matchbox<br />
OP = Optanium<br />
ZT = Mark 7 ® 0-10V<br />
Wiring Configuration<br />
D = 2D, series<br />
M = Modified parallel**<br />
P = Parallel<br />
Q = Quad CFL, series<br />
S = Series<br />
T = Triple CFL, series<br />
TTS = Long twin tube, series<br />
TTP = Long twin tube, parallel<br />
• Plan your lighting installation carefully; consider<br />
using the services of a qualified lighting designer<br />
• Consult your local electric utility regarding demand<br />
side management rebate programs.<br />
• Select the <strong>Advance</strong> electronic ballast which best<br />
matches the requirements of your application. The<br />
technical specifications in this catalog (located on<br />
pages 8-4 to 8-22) will be useful in obtaining bids<br />
from electrical contractors.<br />
• Contact your local <strong>Advance</strong> distributor. You will<br />
find them to be a helpful supplier of both products<br />
and information.<br />
Input Voltage<br />
G = 347V<br />
H = IntelliVolt-Hi (347V through 480V, 50/60 Hz)<br />
I = IntelliVolt (120V through 277V, 50/60 Hz)<br />
R = 120V<br />
V = 277V<br />
X = 220V<br />
* Many current and all future electronic ballast part numbers will not use the “RH-TP” suffixes even though these ballasts will be thermally protected.<br />
** Parallel Wiring Configuration. However, if one lamp fails, all other lamps in the circuit will extinguish.<br />
1-14<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
REMOTE, TANDEM OR THROUGH WIRING DISTANCES<br />
REMOTE MOUNTING OF ELECTRONIC BALLASTS<br />
Unlike magnetic ballasts, electronic ballasts are limited in remote mounting distance from the lamps they operate. The factors limiting<br />
the distance from the electronic ballasts to the lamps are: open circuit voltage as opposed to operating voltage, operating frequency and<br />
the lamp operating current.<br />
As the distance from the high frequency electronic ballasts to the lamp increases, so does the capacitance across the lead wire to the<br />
lamp. This increase in capacitance is important for two reasons. First, if the capacitance is too high, there will not be sufficient open<br />
circuit voltage across the lamp for proper lamp ignition.<br />
Second, if the lamp is capable of ignition, the increased capacitance will cause a loss in the current to the lamp. The added capacitance<br />
creates what is known as a “shunt” around the lamp; in other words the current will leak from the red wire (or blue) to the yellow,<br />
completely bypassing the lamp. The current through the lamp will be reduced, resulting in lower lumens, with the possibility that the lamp<br />
will not be capable of sustained operation.<br />
ELECTRONIC<br />
FLUORESCENT<br />
The Mark 7 ® 0-10V, Mark 10 ® Powerline, and ROVR dimming ballasts are particularly sensitive to high capacitance associated with long<br />
lead wires. The dimming ballast is capable of very low dim levels because constant filament heat is provided to the lamp. If there is any<br />
loss of current, the filament current will be reduced and the lamp will begin to flicker, or it will be completely extinguished. It is also<br />
important that the red and blue leads not be twisted together. Twisting the red and blue leads will add capacitance, causing the lamp to<br />
flicker at the lower dimming levels.<br />
Open circuit voltage is a function of input voltage in some ballast designs, particularly for dedicated voltage ballasts. Cold temperature<br />
starting is a function of open circuit voltage. The lead length recommendations in the following table are for normal rated input voltages<br />
(120V, 277V, 347V) at 25°C ambient temperature.<br />
In summary, there is a wide range and varying types of electronic ballast architectures that are capable of being remote mounted for<br />
an equally wide range of distances. If you are uncertain of the remote mounting restrictions for a particular electronic ballast please<br />
consult Technical Services.<br />
Notes:<br />
1. For Tandem or Through wiring, any lamp can be remote mounted.<br />
2. For Tandem or Through wiring, BLUE lamp must be in same fixture as ballast.<br />
3. For Tandem or Through wiring, RED lamp must be in same fixture as ballast.<br />
4. No Tandem or Through wiring allowed.<br />
5. No Remote, Tandem or Through wiring allowed.<br />
6. For Tandem or Through wiring, RED lamp and BLUE lamp must be in same fixture as ballast.<br />
7. For Tandem or Through wiring, RED lamp and YELLOW lamp must be in same fixture as ballast.<br />
(a) Ballast can be Remote, Tandem or Through wired farther than 20'. See page xxx for details.<br />
(b) Ballast can be Remote, Tandem or Through wired to a maximum 12 feet between ballast and lampholder for (2)F96T8/HO lamps or 20 feet for all other T8/HO lamps.<br />
(c) Ballast can be Remote, Tandem or Through wired to a maximum 10 feet between ballast and lampholder for energy-saving lamps or 20 feet for standard lamps.<br />
Use 18 AWG wire or larger<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-15
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
ELECTRONIC<br />
FLUORESCENT<br />
Note: Ballast should be mounted<br />
at center of fixture to minimize<br />
lead lengths.<br />
1-16<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
GCN-1S32<br />
GCN-2P32<br />
GCN-2S32<br />
GCN-2TTP40-SC<br />
GCN-3S32<br />
GEL-2P32-LW-RH-TP<br />
GEL-2P32-SC<br />
GEL-2P59<br />
GEL-2S32-RH-TP<br />
GEL-2S40-RH-TP<br />
GEL-3P32-RH-TP<br />
GEL-4P32-LW<br />
GEL-4P32-RH-TP<br />
GK-132-TP (a)<br />
GK-2S32-TP (a)<br />
HCN-2S54-90C<br />
HCN-4S54-90C-2LS-G<br />
ICF-1D38-H1-LD<br />
ICF-1H120-M4-BS<br />
ICF-1H120-M4-LD<br />
ICF-2S13-H1-LD<br />
CF-2S13-M1-BS<br />
ICF-2S13-M1-LS<br />
ICF-2S18-H1-LD<br />
ICF-2S18-M1-BS<br />
ICF-2S18-M1-LS<br />
ICF-2S26-H1-LD<br />
ICF-2S26-M1-BS<br />
ICF-2S26-M1-LS<br />
ICF-2S42-M2-BS<br />
ICF-2S42-M2-LD<br />
ICF-2S42-M2-LS<br />
ICF-2S42-90C-M2-BS<br />
ICF-2S42-90C-M2-LD<br />
ICF-2S42-90C-M2-LS<br />
ICF-2S70-M4-BS<br />
ICF-2S70-M4-LD<br />
Allowed Wiring Configuration<br />
Remote<br />
(max length)<br />
Maximum Lead Length (Feet) for Tandem or Through Wiring<br />
(Total length of all wires between ballast and lamp sockets)<br />
Tandem Through Blue Red Yellow Blue/White Brown Orange<br />
Application<br />
Note<br />
20' NA NA 4<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 4' 20' 20' 2<br />
20' Yes Yes 20' 20' 1<br />
No No No 5<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 4' 20' 3<br />
20' Yes Yes 20' 4' 20' 3<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 20' 20' 1<br />
20' Yes Yes 20' 20' 20' 1<br />
20' NA NA 4<br />
20' Yes Yes 4' 20' 20' 2<br />
20' Yes Yes 20' 4' 20' 3<br />
20' Yes Yes 20' 4' 4' 20' 20' 20' 7<br />
15' NA NA 4<br />
1-Lamp 15' NA NA 4<br />
2-Lamp 6' Yes Yes 2' 6' 6' 2<br />
1-Lamp 15' NA NA 4<br />
2-Lamp 6' Yes Yes 2' 6' 6' 2<br />
1-Lamp 15' NA NA 4<br />
2-Lamp 6' Yes Yes 2' 6' 6' 2<br />
1-Lamp 15' NA NA 4<br />
2-Lamp 6' Yes Yes 2' 6' 6' 2<br />
1-Lamp 15' NA NA 4<br />
2-Lamp 6' Yes Yes 2' 6' 6' 2<br />
1-Lamp 15' NA NA 4<br />
2-Lamp 6' Yes Yes 2' 6' 6' 2<br />
6' Yes Yes 2' 6' 6' 2<br />
ELECTRONIC<br />
FLUORESCENT<br />
For nominal input voltage and 25°C ambient temperature.<br />
Notes:<br />
1. For Tandem or Through wiring, any lamp can be remote mounted.<br />
2. For Tandem or Through wiring, BLUE lamp must be in same fixture as ballast.<br />
3. For Tandem or Through wiring, RED lamp must be in same fixture as ballast.<br />
4. No Tandem or Through wiring allowed.<br />
5. No Remote, Tandem or Through wiring allowed.<br />
6. For Tandem or Through wiring, RED lamp and BLUE lamp must be in same fixture as ballast.<br />
7. For Tandem or Through wiring, RED lamp and YELLOW lamp must be in same fixture as ballast.<br />
(a) Ballast can be Remote, Tandem or Through wired farther than 20'. See page xxx for details.<br />
(b) Ballast can be Remote, Tandem or Through wired to a maximum 12 feet between ballast and lampholder for (2)F96T8/HO lamps or 20 feet for all other T8/HO lamps.<br />
(c) Ballast can be Remote, Tandem or Through wired to a maximum 10 feet between ballast and lampholder for energy-saving lamps or 20 feet for standard lamps.<br />
Use 18 AWG wire or larger<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-17
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
ELECTRONIC<br />
FLUORESCENT<br />
ICN-132-MC<br />
ICN-1P32-LW-SC<br />
ICN-1P32-SC<br />
ICN-1S80<br />
ICN-2M32-MC<br />
ICN-2P32-LW-SC<br />
ICN-2P32-SC<br />
ICN-2S24<br />
ICN-2S28<br />
ICN-2S39<br />
ICN-2S54<br />
ICN-2S54-90C<br />
ICN-2S86 (b)<br />
ICN-3P32-LW-SC<br />
ICN-3P32-SC<br />
ICN-3S14-D<br />
ICN-4P32-LW-SC<br />
ICN-4P32-SC<br />
ICN-4S54-90C-2LS<br />
ICN-4S54-90C-2LS-G<br />
IDA-132-SC<br />
IDA-154<br />
IDA-2S32-SC<br />
IDA-2S54<br />
IDA-3S32-G<br />
IDA-4S32<br />
IDL-2S26-M5-BS<br />
IDL-2S26-M5-LD<br />
IDL-2T42-M5-BS<br />
IDL-2T42-M5-LD<br />
IEZ-124-D<br />
IEZ-2S24-D<br />
IIC-132-SC<br />
IIC-2S32-SC<br />
IIC-3S32-SC<br />
IOP-1P32-HL-SC<br />
IOP-1P32-LW-SC<br />
IOP-1P32-SC<br />
IOP-1S32-LW-SC (c)<br />
IOP-1S32-SC (c)<br />
IOP-2P32HL-SC<br />
IOP-2P32-LW-SC<br />
IOP-2P32-SC<br />
Allowed Wiring Configuration<br />
Remote<br />
(max length)<br />
Maximum Lead Length (Feet) for Tandem or Through Wiring<br />
(Total length of all wires between ballast and lamp sockets)<br />
Tandem Through Blue Red Yellow Blue/White Brown Orange<br />
Application<br />
Note<br />
20' NA NA 4<br />
20' NA NA 4<br />
20' NA NA 1<br />
20' NA NA 4<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 4' 20' 3<br />
8' Yes Yes 8' 4' 8' 3<br />
20' Yes Yes 20' 4' 20' 3<br />
20' Yes Yes 20' 4' 20' 3<br />
20' Yes Yes 20' 4' 20' 3<br />
12' Yes Yes 12' 4' 12' 3<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 20' 1<br />
No No No 5<br />
20' Yes Yes 20' 20' 20' 1<br />
20' Yes Yes 20' 20' 20' 1<br />
20' Yes Yes 20' 4' 4' 20' 20' 20' 7<br />
20' Yes Yes 20' 4' 4' 20' 20' 20' 7<br />
No NA NA 5<br />
No NA NA 5<br />
No No No 5<br />
No No Yes 5' 4' 4' 5<br />
No No No 5<br />
No No Yes 1' 1.5' 5' 1.5' 4' 5<br />
No No No 5<br />
No No No 5<br />
No NA NA 5<br />
No No Yes 3' 2' 2' 5<br />
20' NA NA 4<br />
20' Yes Yes 4' 20' 20' 2<br />
No No No 5<br />
20' NA NA 4<br />
20' NA NA 4<br />
20' NA NA 4<br />
10' NA NA 4<br />
10' NA NA 4<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 20' 1<br />
For nominal input voltage and 25°C ambient temperature.<br />
Notes:<br />
1. For Tandem or Through wiring, any lamp can be remote mounted.<br />
2. For Tandem or Through wiring, BLUE lamp must be in same fixture as ballast.<br />
3. For Tandem or Through wiring, RED lamp must be in same fixture as ballast.<br />
4. No Tandem or Through wiring allowed.<br />
5. No Remote, Tandem or Through wiring allowed.<br />
6. For Tandem or Through wiring, RED lamp and BLUE lamp must be in same fixture as ballast.<br />
7. For Tandem or Through wiring, RED lamp and YELLOW lamp must be in same fixture as ballast.<br />
(a) Ballast can be Remote, Tandem or Through wired farther than 20'. See page xxx for details.<br />
(b) Ballast can be Remote, Tandem or Through wired to a maximum 12 feet between ballast and lampholder for (2)F96T8/HO lamps or 20 feet for all other T8/HO lamps.<br />
(c) Ballast can be Remote, Tandem or Through wired to a maximum 10 feet between ballast and lampholder for energy-saving lamps or 20 feet for standard lamps.<br />
Use 18 AWG wire or larger<br />
1-18<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
IOP-2P59-SC<br />
IOP-2S32-LW-SC (c)<br />
IOP-2S32-SC (c)<br />
IOP-3P32-HL-90C-SC<br />
IOP-3P32-LW-SC<br />
IOP-3P32-SC<br />
IOP-3S32-LW-SC (c)<br />
IOP-3S32-SC (c)<br />
IOP-4P32-HL-90C-G<br />
IOP-4P32-LW-SC<br />
IOP-4P32-SC<br />
IOP-4S32-LW-SC (c)<br />
IOP-4S32-SC (c)<br />
IZT-132-SC<br />
IZT-2S26-M5-BS<br />
IZT-2S26-M5-LD<br />
IZT-2S32-SC<br />
IZT-2T42-M3-BS<br />
IZT-2T42-M3-LD<br />
IZT-2T42-M5-BS<br />
IZT-2T42-M5-LD<br />
IZT-2TTS40-SC<br />
IZT-3S32-SC<br />
IZT-4S32<br />
RCF-2S13-H1-LD<br />
RCF-2S13-M1-BS<br />
RCF-2S13-M1-LS<br />
RCF-2S18-H1-LD<br />
RCF-2S18-M1-BS<br />
RCF-2S18-M1-LS<br />
RCF-2S26-H1-LD<br />
RCF-2S26-M1-BS<br />
RCF-2S26-M1-LS<br />
RCN-1S32-SC<br />
RCN-1TTP40-SC<br />
RCN-2P59<br />
RCN-2S32-SC<br />
RCN-2TTP40-SC<br />
RCN-3S32-SC<br />
RCN-3TTP40-SC<br />
RCN-4S32-SC<br />
Allowed Wiring Configuration<br />
Remote<br />
(max length)<br />
Maximum Lead Length (Feet) for Tandem or Through Wiring<br />
(Total length of all wires between ballast and lamp sockets)<br />
Tandem Through Blue Red Yellow Blue/White Brown Orange<br />
20' Yes Yes 20' 20' 1<br />
10' Yes Yes 4' 10' 10' 2<br />
10' Yes Yes 4' 10' 10' 2<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 20' 1<br />
10' Yes Yes 10' 4' 4' 10' 7<br />
10' Yes Yes 10' 4' 4' 10' 7<br />
20' Yes Yes 20' 20' 20' 1<br />
20' Yes Yes 20' 20' 20' 1<br />
20' Yes Yes 20' 20' 20' 1<br />
10' Yes Yes 10' 4' 4' 10' 10' 7<br />
10' Yes Yes 10' 4' 4' 10' 10' 7<br />
6' NA NA 4<br />
No No No 5<br />
6' Yes Yes 6' 6' 6' 1<br />
No No No 5<br />
No No No 5<br />
6' No No 4<br />
No No No 5<br />
No No Yes 1' 1.5' 5' 1.5' 4' 5<br />
1-Lamp 15' No No 4<br />
2-Lamp 6' Yes Yes 2' 6' 6' 2<br />
1-Lamp 15' No No 4<br />
2-Lamp 6' Yes Yes 2' 6' 6' 2<br />
1-Lamp 15' No No 4<br />
Application<br />
Note<br />
2-Lamp 6' Yes Yes 2' 6' 6' 2<br />
20" NA NA 4<br />
20" NA NA 4<br />
20" Yes Yes 20' 20' 1<br />
No Yes Yes 20' 4' 20' 3<br />
20" Yes Yes 20' 20' 1<br />
No Yes Yes 4' 4' 20' 20' 6<br />
20" Yes Yes 20' 20' 1<br />
No Yes Yes 4' 4' 20' 20' 20' 6<br />
ELECTRONIC<br />
FLUORESCENT<br />
For nominal input voltage and 25°C ambient temperature.<br />
Notes:<br />
1. For Tandem or Through wiring, any lamp can be remote mounted.<br />
2. For Tandem or Through wiring, BLUE lamp must be in same fixture as ballast.<br />
3. For Tandem or Through wiring, RED lamp must be in same fixture as ballast.<br />
4. No Tandem or Through wiring allowed.<br />
5. No Remote, Tandem or Through wiring allowed.<br />
6. For Tandem or Through wiring, RED lamp and BLUE lamp must be in same fixture as ballast.<br />
7. For Tandem or Through wiring, RED lamp and YELLOW lamp must be in same fixture as ballast.<br />
(a) Ballast can be Remote, Tandem or Through wired farther than 20'. See page xxx for details.<br />
(b) Ballast can be Remote, Tandem or Through wired to a maximum 12 feet between ballast and lampholder for (2)F96T8/HO lamps or 20 feet for all other T8/HO lamps.<br />
(c) Ballast can be Remote, Tandem or Through wired to a maximum 10 feet between ballast and lampholder for energy-saving lamps or 20 feet for standard lamps.<br />
Use 18 AWG wire or larger<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-19
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
ELECTRONIC<br />
FLUORESCENT<br />
REB-2P32-SC<br />
REB-4P32-SC<br />
REL-1P32-HL-SC<br />
REL-1P32-LW-SC<br />
REL-1P32-SC<br />
REL-1S40-SC<br />
REL-1TTS39<br />
REL-1TTS40<br />
REL-1TTS50<br />
REL-2P17-RH-TP<br />
REL-2P32-HL-SC<br />
REL-2P32-LW-SC<br />
REL-2P32-SC<br />
REL-2P59-SC<br />
REL-2P59-S-RH-TP<br />
REL-2P60-S<br />
REL-2S110<br />
REL-2S40-SC<br />
REL-2S86<br />
REL-2TTS39<br />
REL-2TTS40<br />
REL-2TTS50<br />
REL-3P32-HL-SC<br />
REL-3P32-LW-SC<br />
REL-3P32-SC<br />
REL-3S40-RH-TP<br />
REL-4P32-LW-SC<br />
REL-4P32-SC<br />
RELB-2S40-SC<br />
REZ-132-SC<br />
REZ-154<br />
REZ-1Q18-M2-BS<br />
REZ-1Q18-M2-LD<br />
REZ-1T42-M2-BS<br />
REZ-1T42-M2-LD<br />
REZ-1TTS40-SC<br />
REZ-2Q18-M2-BS<br />
REZ-2Q18-M2-LD<br />
REZ-2Q26-M2-BS<br />
REZ-2Q26-M2-LD<br />
REZ-2S32-SC<br />
REZ-2S54<br />
Allowed Wiring Configuration<br />
Remote<br />
(max length)<br />
Maximum Lead Length (Feet) for Tandem or Through Wiring<br />
(Total length of all wires between ballast and lamp sockets)<br />
Tandem Through Blue Red Yellow Blue/White Brown Orange<br />
Application<br />
Note<br />
20" Yes Yes 20' 20' 1<br />
20" Yes Yes 20' 20' 20' 1<br />
20" NA NA 4<br />
20" NA NA 4<br />
20" NA NA 4<br />
20" NA NA 4<br />
No NA NA 5<br />
No NA NA 5<br />
No NA NA 5<br />
20" Yes Yes 20' 20' 1<br />
20" Yes Yes 20' 20' 1<br />
20" Yes Yes 20' 20' 1<br />
20" Yes Yes 20' 20' 1<br />
20" Yes Yes 20' 20' 1<br />
20" Yes Yes 20' 20' 1<br />
20" Yes Yes 20' 20' 1<br />
20" Yes Yes 4' 20' 20' 2<br />
20" Yes Yes 4' 20' 20' 2<br />
20" Yes Yes 4' 20' 20' 2<br />
No No No 5<br />
No No No 5<br />
No No No 5<br />
20" Yes Yes 20' 20' 1<br />
20" Yes Yes 20' 20' 1<br />
20" Yes Yes 20' 20' 1<br />
No No No 5<br />
20" Yes Yes 20' 20' 20' 1<br />
20" Yes Yes 20' 20' 20' 1<br />
10" Yes Yes 4' 10' 10' 2<br />
6' NA NA 4<br />
No NA NA 5<br />
No NA NA 5<br />
No NA NA 5<br />
6' NA NA 4<br />
No No No 5<br />
No No No 5<br />
6' Yes No 6' 6' 6' 1<br />
No No Yes 5' 4' 4' 5<br />
For nominal input voltage and 25°C ambient temperature.<br />
Notes:<br />
1. For Tandem or Through wiring, any lamp can be remote mounted.<br />
2. For Tandem or Through wiring, BLUE lamp must be in same fixture as ballast.<br />
3. For Tandem or Through wiring, RED lamp must be in same fixture as ballast.<br />
4. No Tandem or Through wiring allowed.<br />
5. No Remote, Tandem or Through wiring allowed.<br />
6. For Tandem or Through wiring, RED lamp and BLUE lamp must be in same fixture as ballast.<br />
7. For Tandem or Through wiring, RED lamp and YELLOW lamp must be in same fixture as ballast.<br />
(a) Ballast can be Remote, Tandem or Through wired farther than 20'. See page xxx for details.<br />
(b) Ballast can be Remote, Tandem or Through wired to a maximum 12 feet between ballast and lampholder for (2)F96T8/HO lamps or 20 feet for all other T8/HO lamps.<br />
(c) Ballast can be Remote, Tandem or Through wired to a maximum 10 feet between ballast and lampholder for energy-saving lamps or 20 feet for standard lamps.<br />
Use 18 AWG wire or larger<br />
1-20<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Allowed Wiring Configuration<br />
Remote<br />
(max length)<br />
Maximum Lead Length (Feet) for Tandem or Through Wiring<br />
(Total length of all wires between ballast and lamp sockets)<br />
Tandem Through Blue Red Yellow Blue/White Brown Orange<br />
Application<br />
Note<br />
REZ-2T42-M3-BS<br />
REZ-2T42-M3-LD<br />
REZ-2TTS40-SC<br />
REZ-3S32-SC<br />
RK-132-TP (a)<br />
RK-2S32-TP (a)<br />
RK-2S34-TP (a)<br />
RMB-1P13-L2<br />
RMB-1P13-S1<br />
RMB-1P13-S2-H<br />
RMB-1P26-S2<br />
RMB-2P13-L2<br />
RMB-2P13-S2<br />
RMB-2P13-S3-H<br />
ROP-2P32-LW-SC<br />
ROP-2P32-SC<br />
ROP-3P32-LW-SC<br />
ROP-3P32-SC<br />
ROP-4P32-HL-90C-G<br />
ROP-4P32-LW-SC<br />
ROP-4P32-SC<br />
RZT-154<br />
RZT-1TTS40<br />
RZT-2S54<br />
VCN-1S32-SC<br />
VCN-1TTP40-SC<br />
VCN-2P59<br />
VCN-2S32-SC<br />
VCN-2TTP40-SC<br />
VCN-3S32-SC<br />
VCN-3TTP40-SC<br />
VCN-4S32-SC<br />
VEL-1P32-HL-SC<br />
VEL-1P32-LW-SC<br />
VEL-1P32-SC<br />
VEL-1S40-SC<br />
VEL-1TTS39<br />
VEL-1TTS40<br />
VEL-1TTS50<br />
VEL-2P17-RH-TP<br />
VEL-2P32-HL-SC<br />
VEL-2P32-LW-SC<br />
No No No 5<br />
6' No No 4<br />
No No No 5<br />
20' NA NA 4<br />
20' Yes Yes 4' 20' 20' 2<br />
20' Yes Yes 4' 20' 20' 2<br />
20' NA NA 4<br />
20' NA NA 4<br />
20' NA NA 4<br />
20' NA NA 4<br />
20' Yes Yes 20' 20' 20' 1<br />
20' Yes Yes 20' 20' 20' 1<br />
20' Yes Yes 20' 20' 20' 1<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 20' 20' 1<br />
20' Yes Yes 20' 20' 20' 1<br />
20' Yes Yes 20' 20' 20' 1<br />
No NA NA 5<br />
6' NA NA 4<br />
No No Yes 5' 4' 4' 5<br />
20" NA NA 4<br />
20" NA NA 4<br />
20" Yes Yes 20' 20' 1<br />
No Yes Yes 20' 4' 20' 3<br />
20" Yes Yes 20' 20' 1<br />
No Yes Yes 4' 4' 20' 20' 6<br />
20" Yes Yes 20' 20' 1<br />
No Yes Yes 4' 4' 20' 20' 20' 6<br />
20" NA NA 4<br />
20" NA NA 4<br />
20" NA NA 4<br />
20" NA NA 4<br />
No NA NA 5<br />
No NA NA 5<br />
No NA NA 5<br />
20" Yes Yes 20' 20' 1<br />
20" Yes Yes 20' 20' 1<br />
20" Yes Yes 20' 20' 1<br />
For nominal input voltage and 25°C ambient temperature.<br />
Notes:<br />
1. For Tandem or Through wiring, any lamp can be remote mounted.<br />
2. For Tandem or Through wiring, BLUE lamp must be in same fixture as ballast.<br />
3. For Tandem or Through wiring, RED lamp must be in same fixture as ballast.<br />
4. No Tandem or Through wiring allowed.<br />
5. No Remote, Tandem or Through wiring allowed.<br />
6. For Tandem or Through wiring, RED lamp and BLUE lamp must be in same fixture as ballast.<br />
7. For Tandem or Through wiring, RED lamp and YELLOW lamp must be in same fixture as ballast.<br />
(a) Ballast can be Remote, Tandem or Through wired farther than 20'. See page xxx for details.<br />
(b) Ballast can be Remote, Tandem or Through wired to a maximum 12 feet between ballast and lampholder for (2)F96T8/HO lamps or 20 feet for all other T8/HO lamps.<br />
(c) Ballast can be Remote, Tandem or Through wired to a maximum 10 feet between ballast and lampholder for energy-saving lamps or 20 feet for standard lamps.<br />
Use 18 AWG wire or larger<br />
ELECTRONIC<br />
FLUORESCENT<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-21
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
ELECTRONIC<br />
FLUORESCENT<br />
VEL-2P32-SC<br />
VEL-2P59-SC<br />
VEL-2P59S-RH-TP<br />
VEL-2P75-S<br />
VEL-2S110<br />
VEL-2S40-SC<br />
VEL-2S86<br />
VEL-2TTS39<br />
VEL-2TTS40<br />
VEL-2TTS50<br />
VEL-3P32-HL-SC<br />
VEL-3P32-LW-SC<br />
VEL-3P32-SC<br />
VEL-3S40-RH-TP<br />
VEL-4P32-LW-SC<br />
VEL-4P32-SC<br />
VEZ-132-SC<br />
VEZ-154<br />
VEZ-1Q18-M2-BS<br />
VEZ-1Q18-M2-LD<br />
VEZ-1T42-M2-BS<br />
VEZ-1T42-M2-LD<br />
VEZ-1TTS40-SC<br />
VEZ-2Q18-M2-BS<br />
VEZ-2Q18-M2-LD<br />
VEZ-2Q26-M2-BS<br />
VEZ-2Q26-M2-LD<br />
VEZ-2S32-SC<br />
VEZ-2S54<br />
VEZ-2T42-M3-BS<br />
VEZ-2T42-M3-LD<br />
VEZ-2TTS40-SC<br />
VEZ-3S32-SC<br />
VK-132-TP (a)<br />
VK-2S32-TP (a)<br />
VK-2S34-TP (a)<br />
VOP-2P32-LW-SC<br />
VOP-2P32-SC<br />
VOP-3P32-LW-SC<br />
VOP-3P32-SC<br />
VOP-4P32-HL-90C-G<br />
VOP-4P32-LW-SC<br />
VOP-4P32-SC<br />
VZT-154<br />
VZT-180<br />
VZT-1TTS40<br />
VZT-2S54<br />
VZT-4S32-HL<br />
Allowed Wiring Configuration<br />
Remote<br />
(max length)<br />
Maximum Lead Length (Feet) for Tandem or Through Wiring<br />
(Total length of all wires between ballast and lamp sockets)<br />
Tandem Through Blue Red Yellow Blue/White Brown Orange<br />
Application<br />
Note<br />
20" Yes Yes 20' 20' 1<br />
20" Yes Yes 20' 20' 1<br />
20" Yes Yes 20' 20' 1<br />
20" Yes Yes 20' 20' 1<br />
20" Yes Yes 4' 20' 20' 2<br />
20" Yes Yes 4' 20' 20' 2<br />
20" Yes Yes 4' 20' 20' 2<br />
No No No 5<br />
No No No 5<br />
No No No 5<br />
20" Yes Yes 20' 20' 1<br />
20" Yes Yes 20' 20' 1<br />
20" Yes Yes 20' 20' 1<br />
No No No 5<br />
20" Yes Yes 20' 20' 20' 1<br />
20" Yes Yes 20' 20' 20' 1<br />
6' NA NA 4<br />
No NA NA 5<br />
No NA NA 5<br />
No NA NA 5<br />
6' NA NA 4<br />
No No No 5<br />
No No No 5<br />
6' Yes No 6' 6' 6' 1<br />
No No Yes 5' 4' 4' 5<br />
No No No 5<br />
6' No No 4<br />
No No No 5<br />
20' NA NA 4<br />
20' Yes Yes 4' 20' 20' 2<br />
20' Yes Yes 4' 20' 20' 2<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 20' 1<br />
20' Yes Yes 20' 20' 20' 1<br />
20' Yes Yes 20' 20' 20' 1<br />
20' Yes Yes 20' 20' 20' 1<br />
No NA NA 5<br />
No NA NA 5<br />
6' NA NA 4<br />
No No Yes 5' 4' 4' 5<br />
No No Yes 1' 1.5' 5' 1.5' 4' 5<br />
For nominal input voltage and 25°C ambient temperature.<br />
SEE PAGE 1-21 FOR NOTES<br />
1-22<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Reading Date Codes for Warranty Date on <strong>Electronic</strong> <strong>Ballasts</strong><br />
Most date codes are stamped on the back of the ballast (opposite the label side). The date code is part of a larger group of numbers and<br />
letters, which call out the various codes for the factory where the ballast was manufactured. Depending upon which <strong>Advance</strong> Transformer<br />
factory manufactured the ballast, the date stamp can vary slightly, in terms of its position on the ballast and the number sequence.<br />
Some electronic ballasts manufactured from 1988 to 1991 may have the date code in ink stamped on the ballast label. Some ballasts have<br />
the manufacturing code printed in ink on the end of the ballast.<br />
A typical date code for an electronic ballast will have the week and the year the ballast was manufactured. Some ballasts will have the day<br />
of the week included too.<br />
ADVANCE TRANSFORMER’S ELECTRONIC BALLASTS HAVE A (5) YEAR WARRANTY FROM DATE OF MANUFACTURE, EFFECTIVE WITH<br />
MANUFACTURING IN JANUARY, 1994 (DATE STAMPED 01-94). ELECTRONIC BALLASTS WITH A DATE CODE PRIOR TO THAT DATE, HAVE<br />
A THREE YEAR WARRANTY (DATE STAMPED 52-93 OR EARLIER).<br />
ELECTRONIC<br />
FLUORESCENT<br />
Some examples of these different date codes that you may find are:<br />
937N1B<br />
B41893<br />
The date code is the 18th week of 1993, stamped one line over the other.<br />
This ballast has a (3) year warranty, that ends the 18th week of 1996.<br />
937N1J<br />
P23292<br />
The date code is the 32nd week of 1992, stamped one line over the other.<br />
This ballast has a (3) year warranty, that ends the 32nd week of 1995.<br />
16<br />
93<br />
973N20P3<br />
The date code is the 16th week of 1993, stamped at the end of the ear on the back.<br />
This ballast has a (3) year warranty, that ends the 16th week of 1996.<br />
892P<br />
259P<br />
24<br />
94<br />
The date code is the 4th week of 1994, stamped on four separate lines.<br />
This ballast has a (5) year warranty that ends the 4th week of 1999.<br />
91405BB0291N<br />
The date code is the 2nd week of 1991, stamped on one line.<br />
This ballast has a (3) year warranty that ends the 2nd week of 1994.<br />
9716T032HD<br />
120432IS24<br />
The date code is the 16th week of 1997, stamped in ink on the end of the ballast.<br />
This ballast has a (5) year warranty that ends the 16th week of 2002.<br />
693P0MMA<br />
53397707<br />
The date code is the 5th day, of the 33rd week of 1997, stamped on the back of the ballast.<br />
05127M50<br />
F2104571<br />
The date code is the 127th day of 2005 stamped on the back of the ballast.<br />
FOR ASSISTANCE IN DETERMINING A DATE CODE – CALL TECHNICAL SERVICE AT 1-800-372-3331<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-23
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
SMARTMATE and Mark 10 Powerline Ballast Kits<br />
NOW FEATURING PATENT-PENDING MOUNTING PLATE ADAPTER!<br />
ELECTRONIC<br />
FLUORESCENT<br />
Kit Contents and Key Features<br />
Key Benefits<br />
SmartMate or Mark 10 Powerline ballast<br />
• Intellivolt Technology<br />
• Dual-entry color-coded connectors<br />
• Multi-Lamp Capability<br />
Mounting Plate Adapter<br />
• Multiple lead wire cutouts, including center hole<br />
• Integral mounting studs<br />
Lead Wire<br />
• Color-coded<br />
• Pre-stripped 3/8" on one end – 5/8" on the other<br />
Wire Extraction Tool<br />
Individually Shrink-Wrapped Kits<br />
Makes ballast selection and installation a breeze<br />
• Provides full range input voltage from 120V to 277V<br />
• Adds to application versatility; simplifies wiring<br />
• Encompasses a wide variety of applications, including<br />
• quads, triple tubes, circline, 2D and long twin-tube lamps<br />
Takes the guess-work out of mounting<br />
• Allows wiring and mounting to existing fixture’s mounting plate<br />
• Eliminates need to stock units with and without studs<br />
Allows installer to pre-wire<br />
• Ensures wiring accuracy<br />
• Meets UL poke-in connector requirements and facilitates<br />
• final connection<br />
Makes for quick disconnections if necessary<br />
Provides fast and accurate identification of ballast and lamp<br />
applications<br />
ICF-2S13-H1-LD-K* REZ-2Q26-M2-LD-K* * kits contain the standard<br />
ICF-2S18-H1-LD-K* VEZ-2Q26-M2-LD-K* ballasts. For lamp and operational data<br />
ICF-2S26-H1-LD-K* REZ-1T42-M2-LD-K* consult pages 1-27 through 1-39<br />
ICF-2S42-M2-LD-K* VEZ-1T42-M2-LD-K* and 2-7<br />
• Ideally suited for replacement of expired electronic ballasts, regardless of brand<br />
or mounting configuration.<br />
• Dramatically simplifies the upgrading of incandescent fixtures to energy-saving CFL.<br />
• Compatible with most J-Box covers<br />
1-24<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
NOTES<br />
ELECTRONIC<br />
FLUORESCENT<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 1-25
T4<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 7 - 9W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
CFT7W/2G7 - 7W CFL Twin Tube Lamp (CF7DS/E)<br />
RMB-1P13-L2<br />
L2<br />
8 1.00 150 0.13<br />
1 120 IS Matchbox † RMB-1P13-S1<br />
0/-18 S1<br />
RMB-1P13-S2-H 8 1.00 25 0.07<br />
S2<br />
RMB-2P13-L2<br />
L2<br />
16 1.10 150 0.24<br />
2 120 IS Matchbox † RMB-2P13-S2<br />
0/-18 S2<br />
RMB-2P13-S3-H 16 1.00 15 0.14<br />
S3<br />
CFT9W/2G7 - 9W CFL Twin Tube Lamp (CF9DS/E)<br />
RMB-1P13-L2<br />
L2<br />
10 1.10 150 0.16<br />
1 120 IS Matchbox † RMB-1P13-S1<br />
0/-18 S1<br />
RMB-1P13-S2-H 10 1.05 20 0.09<br />
S2<br />
RMB-2P13-L2<br />
L2<br />
20 1.10 125 0.29<br />
2 120 IS Matchbox † RMB-2P13-S2<br />
0/-18 S2<br />
RMB-2P13-S3-H 20 1.05 10 0.17<br />
S3<br />
Dim.<br />
Wiring<br />
Dia.<br />
160<br />
159<br />
160<br />
159<br />
† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />
S1 Model<br />
S2 Model<br />
L2 Model<br />
S3 Model<br />
1 or 2 lamp linear ballast, plastic enclosure<br />
See page 1-28 for Wiring Diagrams<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-26<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 13 - 18W Quad Lamps<br />
T4<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
CFQ13W/G24q - 13W CFL Quad Tube Lamp (PL-C13W/4P, F13DBX/4P, CF13DD/E)<br />
RMB-1P13-L2<br />
L2<br />
14 1.00 150 0.20<br />
IS Matchbox † RMB-1P13-S1<br />
S1<br />
120<br />
RMB-1P13-S2-H 14 0.85 20 0.12<br />
S2<br />
RCF-2S13-H1-LD-QS<br />
AmbiStar RCF-2S13-M1-BS-QS 16 1.00 10 0.13<br />
RCF-2S13-M1-LS-QS<br />
QS<br />
1 ICF-2S13-H1-LD-QS<br />
0/-18<br />
ICF-2S13-M1-BS-QS 16 1.00 10 0.13-0.06<br />
ICF-2S13-M1-LS-QS<br />
Size 1<br />
120-277<br />
SmartMate ICF-2S13-H1-LD<br />
PS<br />
ICF-2S13-H1-LD-K ➀<br />
ICF-2S13-M1-BS<br />
16 1.00 10 0.13-0.06<br />
ICF-2S13-M1-LS<br />
RMB-2P13-L2<br />
L2<br />
25 0.95 125 0.35<br />
IS Matchbox † RMB-2P13-S2<br />
S2<br />
120<br />
RMB-2P13-S3-H 27 0.90 10 0.23<br />
S3<br />
RCF-2S13-H1-LD-QS<br />
AmbiStar RCF-2S13-M1-BS-QS 29 1.00 10 0.25<br />
RCF-2S13-M1-LS-QS<br />
QS<br />
2 ICF-2S13-H1-LD-QS<br />
0/-18<br />
ICF-2S13-M1-BS-QS 29 1.00 10 0.25-0.11<br />
ICF-2S13-M1-LS-QS<br />
Size 1<br />
120-277<br />
SmartMate ICF-2S13-H1-LD<br />
PS<br />
ICF-2S13-H1-LD-K ➀<br />
ICF-2S13-M1-BS<br />
29 1.00 10 0.25-0.11<br />
ICF-2S13-M1-LS<br />
CFQ18W/G24q - 18W CFL Quad Tube Lamp (PL-C18W/4 P, F18DBX/4P, CF18DD/E)<br />
RMB-2P13-L2<br />
L2<br />
16 0.80 150 0.26<br />
IS Matchbox † RMB-2P13-S2<br />
S2 *159<br />
120<br />
RMB-2P13-S3-H 15 0.80 15 0.13<br />
S3<br />
RCF-2S18-H1-LD-QS<br />
AmbiStar RCF-2S18-M1-BS-QS 19 1.00 10 0.16<br />
RCF-2S18-M1-LS-QS<br />
QS<br />
1 ICF-2S18-H1-LD-QS<br />
0/-18<br />
ICF-2S18-M1-BS-QS 19 1.00 10 0.16-0.07<br />
ICF-2S18-M1-LS-QS<br />
Size 1 160<br />
120-277<br />
SmartMate ICF-2S18-H1-LD<br />
PS<br />
ICF-2S18-H1-LD-K ➀<br />
ICF-2S18-M1-BS<br />
19 1.00 10 0.16-0.07<br />
ICF-2S18-M1-LS<br />
RCF-2S18-H1-LD-QS<br />
120<br />
AmbiStar RCF-2S18-M1-BS-QS 35 0.95 10 0.30<br />
QS<br />
RCF-2S18-M1-LS-QS<br />
ICF-2S18-H1-LD-QS<br />
2<br />
ICF-2S18-M1-BS-QS 35 0.95 10 0.30-0.13<br />
ICF-2S18-M1-LS-QS<br />
0/-18 Size 1 159<br />
120-277<br />
SmartMate ICF-2S18-H1-LD<br />
PS<br />
ICF-2S18-H1-LD-K ➀<br />
ICF-2S18-M1-BS<br />
ICF-2S18-M1-LS<br />
35 0.95 10 0.30-0.13<br />
Max.<br />
THD<br />
%<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
160<br />
159<br />
ELECTRONIC<br />
FLUORESCENT<br />
HIGH FREQUENCY<br />
ELECTRONIC<br />
†<br />
Matchbox ballasts are normal power factor except -H models which are high power factor.<br />
➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
See page 1-26 for Dimensions<br />
See page 1-28 for Wiring Diagrams<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-27
T4<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 26W Quad Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
CFQ26W/G24q - 26W CFL Quad Tube Lamp (PL-C26W/4P, F26DBX/4P, CF26DD/E)<br />
IS Matchbox † RMB-1P26-S2<br />
26 0.95 125 0.38<br />
S2<br />
120<br />
RCF-2S26-H1-LD-QS<br />
AmbiStar RCF-2S26-M1-BS-QS 27 1.00 10 0.23<br />
QS<br />
RCF-2S26-M1-LS-QS<br />
ICF-2S26-H1-LD-QS<br />
1 ICF-2S26-M1-BS-QS 27 1.00 10 0.23-0.10 0/-18<br />
ICF-2S26-M1-LS-QS<br />
Size 1<br />
120-277<br />
SmartMate ICF-2S26-H1-LD<br />
PS<br />
ICF-2S26-H1-LD-K ➀<br />
ICF-2S26-M1-BS<br />
27 1.00 10 0.23-0.10<br />
ICF-2S26-M1-LS<br />
RCF-2S26-H1-LD-QS<br />
120<br />
AmbiStar RCF-2S26-M1-BS-QS 51 1.00 10 0.43<br />
QS<br />
RCF-2S26-M1-LS-QS<br />
ICF-2S26-H1-LD-QS<br />
ICF-2S26-M1-BS-QS 51 1.00 10 0.43-0.19<br />
ICF-2S26-M1-LS-QS<br />
Size 1<br />
ICF-2S26-H1-LD<br />
ICF-2S26-H1-LD-K ➀<br />
51 1.00 10 0.43-0.19<br />
2 ICF-2S26-M1-BS<br />
0/-18<br />
120-277<br />
SmartMate<br />
ICF-2S26-M1-LS<br />
ICF-2S42-M2-BS<br />
PS<br />
ICF-2S42-M2-LD<br />
ICF-2S42-M2-LD-K ➀<br />
52 1.00 10 0.43-0.19<br />
ICF-2S42-M2-LS<br />
Size 2<br />
ICF-2S42-90C-M2-BS<br />
ICF-2S42-90C-M2-LD 52 1.00 10 0.43-0.19<br />
ICF-2S42-90C-M2-LS<br />
Max.<br />
THD<br />
%<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
160<br />
159<br />
† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />
➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />
* Note: For 1-lamp operation on 2-lamp ballast, use red and yellow connectors<br />
See page 1-26 for Dimensions<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-28<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 13W Triple Lamps<br />
T4<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
CFTR13W/GX24q - 13W CFL Triple Tube Lamp (F13TBX/4P, CF13DT/E)<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
RMB-1P13-L2<br />
L2<br />
14 1.00 150 0.20<br />
IS Matchbox † RMB-1P13-S1<br />
S1<br />
120<br />
RMB-1P13-S2-H 14 0.85 20 0.12<br />
S2<br />
RCF-2S13-H1-LD-QS<br />
AmbiStar RCF-2S13-M1-BS-QS 16 1.00 10 0.13<br />
RCF-2S13-M1-LS-QS<br />
QS<br />
1 ICF-2S13-H1-LD-QS<br />
0/-18<br />
ICF-2S13-M1-BS-QS 16 1.00 10 0.13-0.06<br />
ICF-2S13-M1-LS-QS<br />
Size 1<br />
120-277<br />
SmartMate ICF-2S13-H1-LD<br />
PS<br />
ICF-2S13-H1-LD-K ➀<br />
ICF-2S13-M1-BS<br />
16 1.00 10 0.13-0.06<br />
ICF-2S13-M1-LS<br />
RMB-2P13-L2<br />
L2<br />
25 0.95 125 0.35<br />
IS Matchbox † RMB-2P13-S2<br />
S2<br />
120<br />
RMB-2P13-S3-H 27 0.90 10 0.23<br />
S3<br />
RCF-2S13-H1-LD-QS<br />
AmbiStar RCF-2S13-M1-BS-QS 29 1.00 10 0.25<br />
RCF-2S13-M1-LS-QS<br />
QS<br />
2 ICF-2S13-H1-LD-QS<br />
0/-18<br />
ICF-2S13-M1-BS-QS 29 1.00 10 0.25-0.11<br />
ICF-2S13-M1-LS-QS<br />
Size 1<br />
120-277<br />
SmartMate ICF-2S13-H1-LD<br />
PS<br />
ICF-2S13-H1-LD-K ➀<br />
ICF-2S13-M1-BS<br />
29 1.00 10 0.25-0.11<br />
ICF-2S13-M1-LS<br />
† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />
➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />
Max.<br />
THD<br />
%<br />
Dim.<br />
Wiring<br />
Dia.<br />
160<br />
159<br />
ELECTRONIC<br />
FLUORESCENT<br />
* Note: For 1-lamp operation on 2-lamp ballast, use red and yellow connectors 1-29<br />
See page 1-26 for Dimensions<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
T4<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 18W Triple Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
CFTR18W/GX24q - 18W CFL Triple Tube Lamp (PL-T18W/4P, F18TBX/4P, CF18DT/E)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
RMB-2P13-L2<br />
L2<br />
16 0.80 150 0.26<br />
IS Matchbox † RMB-2P13-S2<br />
S2 *159<br />
120<br />
RMB-2P13-S3-H 15 0.80 15 0.13<br />
S3<br />
RCF-2S18-H1-LD-QS<br />
AmbiStar RCF-2S18-M1-BS-QS 20 1.05 10 0.17<br />
RCF-2S18-M1-LS-QS<br />
QS<br />
1 ICF-2S18-H1-LD-QS<br />
0/-18<br />
ICF-2S18-M1-BS-QS 20 1.05 10 0.17-0.08<br />
ICF-2S18-M1-LS-QS<br />
Size 1 160<br />
120-277<br />
SmartMate ICF-2S18-H1-LD<br />
PS<br />
ICF-2S18-H1-LD-K ➀<br />
ICF-2S18-M1-BS<br />
20 1.05 10 0.17-0.08<br />
ICF-2S18-M1-LS<br />
RCF-2S18-H1-LD-QS<br />
120<br />
AmbiStar RCF-2S18-M1-BS-QS 39 1.05 10 0.33<br />
QS<br />
RCF-2S18-M1-LS-QS<br />
ICF-2S18-H1-LD-QS<br />
2<br />
ICF-2S18-M1-BS-QS 39 1.05 10 0.33-0.14<br />
ICF-2S18-M1-LS-QS<br />
0/-18 Size 1 159<br />
120-277<br />
SmartMate ICF-2S18-H1-LD<br />
PS<br />
ICF-2S18-H1-LD-K ➀<br />
ICF-2S18-M1-BS<br />
ICF-2S18-M1-LS<br />
39 1.05 10 0.33-0.14<br />
Max.<br />
THD<br />
%<br />
Line<br />
Current<br />
(Amps)<br />
Dim.<br />
Wiring<br />
Dia.<br />
† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />
➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />
* Note: For 1-lamp operation on 2-lamp ballast, use red and yellow connectors<br />
See page 1-26 for Dimensions<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-30<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 26 - 32W Triple Lamps<br />
T4<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
CFTR26W/GX24q - 26W CFL Triple Tube Lamp (PL-T26W/4P, F26TBX/4P, CF26DT/E)<br />
IS Matchbox † RMB-1P26-S2<br />
26 0.95 125 0.38<br />
S2<br />
120<br />
RCF-2S26-H1-LD-QS<br />
AmbiStar RCF-2S26-M1-BS-QS 29 1.10 10 0.24<br />
RCF-2S26-M1-LS-QS<br />
QS<br />
ICF-2S26-H1-LD-QS<br />
0/-18<br />
Size 1<br />
1<br />
ICF-2S26-M1-BS-QS 29 1.10 10 0.24-0.11<br />
ICF-2S26-M1-LS-QS<br />
120-277<br />
SmartMate ICF-2S26-H1-LD<br />
PS<br />
ICF-2S26-H1-LD-K ➀<br />
ICF-2S26-M1-BS<br />
29 1.10 10 0.24-0.11<br />
ICF-2S26-M1-LS<br />
RCF-2S26-H1-LD-QS<br />
120<br />
AmbiStar RCF-2S26-M1-BS-QS 54 1.00 10 0.45<br />
QS<br />
RCF-2S26-M1-LS-QS<br />
ICF-2S26-H1-LD-QS<br />
ICF-2S26-M1-BS-QS 54 1.00 10 0.45-0.20<br />
ICF-2S26-M1-LS-QS<br />
Size 1<br />
ICF-2S26-H1-LD<br />
ICF-2S26-H1-LD-K ➀<br />
54 1.00 10 0.45-0.20<br />
2<br />
ICF-2S26-M1-BS<br />
0/-18<br />
120-277<br />
SmartMate<br />
ICF-2S26-M1-LS<br />
ICF-2S42-M2-BS<br />
PS<br />
ICF-2S42-M2-LD<br />
ICF-2S42-M2-LD-K ➀<br />
55 1.00 10 0.46-0.21<br />
ICF-2S42-M2-LS<br />
Size 2<br />
ICF-2S42-90C-M2-BS<br />
ICF-2S42-90C-M2-LD 55 1.00 10 0.46-0.21<br />
ICF-2S42-90C-M2-LS<br />
CFTR32W/GX24q - 32W CFL Triple Tube Lamp (PL-T32W/4P, F32TBX/4P, CF32DT/E)<br />
1<br />
2<br />
Input<br />
Volts<br />
120<br />
120-277<br />
277<br />
Lamp<br />
Starting<br />
Method<br />
QS<br />
PS<br />
PS<br />
Ballast<br />
Family<br />
AmbiStar<br />
SmartMate<br />
SmartMate<br />
Catalog Number<br />
RCF-2S26-H1-LD-QS<br />
RCF-2S26-M1-BS-QS<br />
RCF-2S26-M1-LS-QS<br />
ICF-2S26-H1-LD-QS<br />
ICF-2S26-M1-BS-QS<br />
ICF-2S26-M1-LS-QS<br />
ICF-2S26-H1-LD<br />
ICF-2S26-H1-LD-K ➀<br />
ICF-2S26-M1-BS<br />
ICF-2S26-M1-LS<br />
ICF-2S42-M2-BS<br />
ICF-2S42-M2-LD<br />
ICF-2S42-M2-LD-K ➀<br />
ICF-2S42-M2-LS<br />
ICF-2S42-90C-M2-BS<br />
ICF-2S42-90C-M2-LD<br />
ICF-2S42-90C-M2-LS<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
36<br />
36<br />
36<br />
68<br />
68<br />
Ballast<br />
Factor<br />
0.98<br />
0.98<br />
0.98<br />
0.98<br />
0.98<br />
Max.<br />
THD<br />
%<br />
10<br />
10<br />
10<br />
10<br />
10<br />
Line<br />
Current<br />
(Amps)<br />
0.31<br />
0.31-0.13<br />
0.31-0.13<br />
0.57-0.25<br />
0.57-0.25<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
0/-18<br />
0/-18<br />
Dim.<br />
Size 1<br />
Size 2<br />
Wiring<br />
Dia.<br />
160<br />
159<br />
160<br />
159<br />
ELECTRONIC<br />
FLUORESCENT<br />
† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />
➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
See page 1-26 for Dimensions<br />
See page 1-28 for Wiring Diagrams<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-31
T4<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 42 - 70W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
CFTR42W/GX24q - 42W CFL Triple Tube Lamp (PL-T42W/4P, F42TBX/4P, CF42DT/E)<br />
RCF-2S26-H1-LD-QS<br />
120<br />
AmbiStar RCF-2S26-M1-BS-QS 46 0.98 10 0.38<br />
QS<br />
RCF-2S26-M1-LS-QS<br />
ICF-2S26-H1-LD-QS<br />
1<br />
ICF-2S26-M1-BS-QS 46 0.98 10 0.38-0.17<br />
ICF-2S26-M1-LS-QS<br />
0/-18 Size 1 160<br />
120-277<br />
SmartMate ICF-2S26-H1-LD<br />
PS<br />
ICF-2S26-H1-LD-K ➀<br />
ICF-2S26-M1-BS<br />
ICF-2S26-M1-LS<br />
ICF-2S42-M2-BS<br />
ICF-2S42-M2-LD<br />
ICF-2S42-M2-LD-K ➀<br />
46<br />
93<br />
0.98<br />
0.97<br />
10<br />
10<br />
0.38-0.17<br />
0.78-0.33<br />
2 120-277 PS SmartMate ICF-2S42-M2-LS<br />
ICF-2S42-90C-M2-BS<br />
0/-18 Size 2 159<br />
ICF-2S42-90C-M2-LD<br />
ICF-2S42-90C-M2-LS<br />
93 0.97 10 0.78-0.33<br />
CFTR57W/GX24q - 57W CFL Lamp (F57QBX/4P, CF57DT/E)<br />
ICF-2S42-M2-BS<br />
ICF-2S42-M2-LD<br />
ICF-2S42-M2-LD-K ➀<br />
59 0.94 10 0.80-0.21<br />
1 120-277 PS SmartMate ICF-2S42-M2-LS<br />
ICF-2S42-90C-M2-BS<br />
14/-10 Size 1 160<br />
2 120-277 PS SmartMate<br />
ICF-2S42-90C-M2-LD<br />
ICF-2S42-90C-M2-LS<br />
ICF-2S70-M4-BS<br />
ICF-2S70-M4-LD<br />
59<br />
128-126<br />
0.94<br />
1.00<br />
10<br />
10<br />
0.80-0.21<br />
1.07-0.46 0/-18 Size 4 159<br />
CFTR70W/GX24q - 70W CFL Lamp (F70QBX/4P)<br />
ICF-2S42-M2-BS<br />
ICF-2S42-M2-LD<br />
ICF-2S42-M2-LD-K ➀<br />
75 0.96 10 0.63-0.27<br />
1 120-277 PS SmartMate ICF-2S42-M2-LS<br />
ICF-2S42-90C-M2-BS<br />
14/-10 Size 2 160<br />
2 120-277 PS SmartMate<br />
ICF-2S42-90C-M2-LD<br />
ICF-2S42-90C-M2-LS<br />
ICF-2S70-M4-BS<br />
ICF-2S70-M4-LD<br />
75<br />
156-152<br />
0.96<br />
1.00<br />
10<br />
10<br />
0.63-0.27<br />
1.30-0.56 0/-18 Size 4 159<br />
Max.<br />
THD<br />
%<br />
Dim.<br />
Wiring<br />
Dia.<br />
➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />
See page 1-33 for Dimensions and Wiring Diagrams<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-32<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 60 - 120W Lamps<br />
T4<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
1<br />
2<br />
Input<br />
Volts<br />
120-277<br />
120-277<br />
Lamp<br />
Starting<br />
Method<br />
60W PLH (PL-H60W/4P)<br />
PS<br />
PS<br />
Ballast<br />
Family<br />
SmartMate<br />
Catalog Number<br />
ICF-1H120-M4-BS<br />
ICF-1H120-M4-LD<br />
ICF-1H120-M4-BS<br />
ICF-1H120-M4-LD<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
70<br />
139-136<br />
Ballast<br />
Factor<br />
1.00<br />
1.00<br />
Max.<br />
THD<br />
%<br />
15<br />
10<br />
Line<br />
Current<br />
(Amps)<br />
0.59-0.26<br />
1.16-0.50<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
-22/-30<br />
-22/-30<br />
Dim.<br />
Size 4<br />
Size 4<br />
Wiring<br />
Dia.<br />
160<br />
159<br />
ELECTRONIC<br />
FLUORESCENT<br />
85W PLH (PL-H85W/4P)<br />
1<br />
120-277<br />
PS<br />
SmartMate<br />
ICF-1H120-M4-BS<br />
ICF-1H120-M4-LD<br />
98-97<br />
1.00<br />
10<br />
0.82-0.36<br />
-22/-30<br />
Size 4<br />
160<br />
120W PLH (PL-H120W/4P)<br />
1<br />
120-277<br />
PS<br />
SmartMate<br />
ICF-1H120-M4-BS<br />
ICF-1H120-M4-LD<br />
139-136<br />
1.00<br />
10<br />
1.16-0.50<br />
-22/-30<br />
Size 4<br />
160<br />
* Note: For 1-lamp operation on 2-lamp ballast, use red and yellow connectors<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-33
FT5<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 18 - 36W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
FT18W/2G11/RS - 18W (F18BX/RS, FT18DL/RS)<br />
1 120 IS Matchbox † RMB-1P26-S2<br />
23 1.00 150 0.37 0/-18 S2 160<br />
FT24W/2G11 - 24/27W (PL-L24W, F27BX/RS, FT24DL)<br />
120 IS Matchbox † RMB-1P26-S2<br />
26 0.95 150 0.40<br />
S2 160<br />
1<br />
ICN-2S24<br />
27 1.02 10 0.23-0.10 0/-18<br />
120-277 PS Centium<br />
ICN-2S39<br />
29 1.12 15 0.24-0.12<br />
ICF-2S26-H1-LD<br />
D 73<br />
ICF-2S26-H1-LD-K ➀<br />
ICF-2S26-M1-BS<br />
ICF-2S26-M1-LS<br />
ICF-2S42-M2-BS<br />
48 0.93 10 0.41-0.18<br />
Size 1 160<br />
SmartMate ICF-2S42-M2-LD<br />
2 120-277 PS<br />
ICF-2S42-M2-LD-K ➀<br />
0/-18<br />
ICF-2S42-M2-LS<br />
ICF-2S42-90C-M2-BS<br />
ICF-2S42-90C-M2-LD<br />
ICF-2S42-90C-M2-LS<br />
48 0.93 15 0.40-0.18<br />
Size 2 159<br />
Centium<br />
ICN-2S24<br />
52 1.00 10 0.44-0.19<br />
ICN-2S39<br />
54 1.10 10 0.46-0.20<br />
D 74<br />
FT36W/2G11 - 36/39W (PL-L36W, F39BX/RS, FT36DL)<br />
1<br />
2<br />
3<br />
4<br />
Input<br />
Volts<br />
120<br />
277<br />
120-277<br />
347-480<br />
120<br />
277<br />
120-277<br />
347-480<br />
120-277<br />
347-480<br />
120-277<br />
347-480<br />
Lamp<br />
Starting<br />
Method<br />
RS<br />
PS<br />
RS<br />
PS<br />
PS<br />
PS<br />
Ballast<br />
Family<br />
Standard<br />
Centium<br />
Standard<br />
Centium<br />
Centium<br />
Centium<br />
Catalog Number<br />
REL-1TTS39<br />
VEL-1TTS39<br />
ICN-2S24<br />
ICN-2S39<br />
ICN-2S54<br />
ICN-2S54-90C<br />
HCN-2S54-90C<br />
REL-2TTS39<br />
VEL-2TTS39<br />
ICN-2S39<br />
ICN-2S54<br />
ICN-2S54-90C<br />
HCN-2S54-90C<br />
ICN-4S54-90C-2LS<br />
ICN-4S54-90C-2LS-G<br />
HCN-4S54-90C-2LS-G<br />
ICN-4S54-90C-2LS<br />
ICN-4S54-90C-2LS<br />
HCN-4S54-90C-2LS-G<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
39<br />
34<br />
36<br />
46<br />
46<br />
70<br />
69<br />
89-86<br />
89<br />
133-132<br />
137-135<br />
176-173<br />
182-180<br />
Ballast<br />
Factor<br />
1.00<br />
0.90<br />
0.96<br />
1.22<br />
1.22<br />
0.85<br />
0.94<br />
1.20<br />
1.20<br />
1.20<br />
1.20<br />
1.20<br />
1.20<br />
Max.<br />
THD<br />
%<br />
20<br />
10<br />
15<br />
20<br />
15<br />
20<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
Line<br />
Current<br />
(Amps)<br />
0.35<br />
0.15<br />
0.29-0.13<br />
0.30-0.13<br />
0.39-0.18<br />
0.13-0.10<br />
0.59<br />
0.25<br />
0.59-0.25<br />
0.75-0.32<br />
0.26-0.19<br />
1.11-0.49<br />
0.40-0.29<br />
1.47-0.64<br />
0.53-0.38<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
50/10<br />
0/-18<br />
50/10<br />
0/-18<br />
0/-18<br />
0/-18<br />
Dim.<br />
A<br />
D<br />
A<br />
D<br />
E<br />
G<br />
E<br />
G<br />
Wiring<br />
Dia.<br />
93<br />
73<br />
94<br />
74<br />
*75<br />
75<br />
† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />
➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />
See page 1-36 for Dimensions<br />
See page 1-37 for Wiring Diagrams<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-34<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 40W Lamps<br />
FT5<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
FT40W/2G11/RS - 40W (PL-L40W, F40/30BX, FT40DL/RS)<br />
RS Standard REL-1TTS40<br />
120<br />
RCN-1TTP40-SC<br />
IS Centium<br />
RCN-2TTP40-SC<br />
RS Standard VEL-1TTS40<br />
277<br />
VCN-1TTP40-SC<br />
IS<br />
VCN-2TTP40-SC<br />
Centium<br />
ICN-2S24<br />
1<br />
ICN-2S39<br />
ICF-2S42-M2-BS<br />
120-277 PS<br />
ICF-2S42-M2-LD<br />
ICF-2S42-M2-LD-K ➀<br />
SmartMate ICF-2S42-M2-LS<br />
347 IS<br />
RS<br />
Centium<br />
Standard<br />
ICF-2S42-90C-M2-BS<br />
ICF-2S42-90C-M2-LD<br />
ICF-2S42-90C-M2-LS<br />
GCN-2TTP40-SC<br />
REL-2TTS40<br />
120<br />
RCN-2TTP40-SC<br />
IS Centium<br />
RCN-3TTP40-SC<br />
RS Standard VEL-2TTS40<br />
277<br />
VCN-2TTP40-SC<br />
IS Centium<br />
VCN-3TTP40-SC<br />
2<br />
ICF-2S42-M2-BS<br />
ICF-2S42-M2-LD<br />
120-277<br />
347<br />
PS<br />
IS<br />
SmartMate<br />
Centium<br />
ICF-2S42-M2-LD-K ➀<br />
ICF-2S42-M2-LS<br />
ICF-2S42-90C-M2-BS<br />
ICF-2S42-90C-M2-LD<br />
ICF-2S42-90C-M2-LS<br />
GCN-2TTP40-SC<br />
3<br />
120<br />
RCN-3TTP40-SC<br />
IS Centium<br />
277<br />
VCN-3TTP40-SC<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
44<br />
41<br />
44<br />
44<br />
41<br />
44<br />
47<br />
50<br />
44<br />
42<br />
71<br />
72<br />
78<br />
71<br />
72<br />
78<br />
78<br />
78<br />
65<br />
103<br />
Ballast<br />
Factor<br />
1.00<br />
0.90<br />
1.00<br />
1.00<br />
0.90<br />
0.97<br />
1.00<br />
1.10<br />
0.95<br />
1.04<br />
0.85<br />
0.88<br />
0.97<br />
0.85<br />
0.88<br />
0.95<br />
0.95<br />
0.95<br />
0.88<br />
0.86<br />
Max.<br />
THD<br />
%<br />
20<br />
10<br />
10<br />
20<br />
10<br />
15<br />
10<br />
10<br />
10<br />
44 0.95 10<br />
10<br />
20<br />
10<br />
10<br />
20<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
Line<br />
Current<br />
(Amps)<br />
0.37<br />
0.35<br />
0.38<br />
0.16<br />
0.16<br />
0.16<br />
0.40-0.17<br />
0.42-0.19<br />
0.37-0.16<br />
0.37-0.16<br />
0.13<br />
0.60<br />
0.62<br />
0.66<br />
0.26<br />
0.26<br />
0.28<br />
0.66-0.28<br />
0.66-0.28<br />
0.19<br />
0.88<br />
0.37<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
50/10<br />
0/-18<br />
50/10<br />
0/-18<br />
50/10<br />
0/-18<br />
50/10<br />
0/-18<br />
0/-18<br />
Dim.<br />
A<br />
B<br />
A<br />
B<br />
D<br />
Size 2<br />
B<br />
A<br />
B<br />
A<br />
B<br />
Size 2<br />
B<br />
B<br />
Wiring<br />
Dia.<br />
93<br />
70<br />
93<br />
70<br />
73<br />
160<br />
70<br />
94<br />
71<br />
94<br />
71<br />
159<br />
71<br />
72<br />
ELECTRONIC<br />
FLUORESCENT<br />
➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />
See page 1-36 for Dimensions<br />
See page 1-37 for Wiring Diagrams<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-35
FT5<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 50W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
1<br />
2<br />
3<br />
4<br />
Input<br />
Volts<br />
FT50W/2G11/RS - 50W (PL-L50W, F50BX/RS)<br />
120<br />
RS Standard<br />
277<br />
120-277<br />
347-480<br />
120<br />
277<br />
120-277<br />
347-480<br />
120-277<br />
347-480<br />
120-277<br />
347-480<br />
Lamp<br />
Starting<br />
Method<br />
PS<br />
RS<br />
PS<br />
PS<br />
PS<br />
Ballast<br />
Family<br />
Centium<br />
Standard<br />
Centium<br />
Centium<br />
Centium<br />
Catalog Number<br />
REL-1TTS50<br />
VEL-1TTS50<br />
ICN-2S54<br />
ICN-2S54-90C<br />
HCN-2S54-90C<br />
REL-2TTS50<br />
VEL-2TTS50<br />
ICN-2S54<br />
ICN-2S54-90C<br />
HCN-2S54-90C<br />
ICN-4S54-90C-2LS<br />
ICN-4S54-90C-2LS-G<br />
HCN-4S54-90C-2LS-G<br />
ICN-4S54-90C-2LS<br />
ICN-4S54-90C-2LS<br />
HCN-4S54-90C-2LS-G<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
54<br />
61<br />
61<br />
106<br />
118-115<br />
118<br />
178-175<br />
185-183<br />
235-230<br />
236-234<br />
Ballast<br />
Factor<br />
0.98<br />
1.12<br />
1.12<br />
0.98<br />
1.10<br />
1.10<br />
1.10<br />
1.10<br />
1.10<br />
1.10<br />
Max.<br />
THD<br />
%<br />
20<br />
15<br />
10<br />
20<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
Line<br />
Current<br />
(Amps)<br />
0.46<br />
0.20<br />
0.51-0.23<br />
0.18-0.13<br />
0.90<br />
0.39<br />
0.99-0.43<br />
0.34-0.25<br />
1.49-0.65<br />
0.54-0.39<br />
1.96-0.84<br />
0.68-0.49<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
50/10<br />
0/-18<br />
50/10<br />
0/-18<br />
0/-18<br />
0/-18<br />
Dim.<br />
A<br />
D<br />
A<br />
D<br />
E<br />
G<br />
E<br />
G<br />
Wiring<br />
Dia.<br />
93<br />
73<br />
94<br />
74<br />
*75<br />
75<br />
Fig. A<br />
1.18"<br />
8.90"<br />
9.5"<br />
1.7"<br />
Fig. B<br />
Fig. D<br />
Fig. E<br />
S2 Model<br />
Fig. G<br />
See page 1-37 for Wiring Diagrams<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-36<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 55 - 80W Lamps<br />
FT5<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
1<br />
2<br />
3<br />
Input<br />
Volts<br />
FT55W/2G11 - 55W (F55BX, FT55DL)<br />
120<br />
RS Standard<br />
277<br />
120-277<br />
347-480<br />
120<br />
277<br />
120-277<br />
347-480<br />
120-277<br />
347-480<br />
Lamp<br />
Starting<br />
Method<br />
PS<br />
RS<br />
PS<br />
PS<br />
Ballast<br />
Family<br />
Centium<br />
Standard<br />
Centium<br />
Centium<br />
4<br />
120-277<br />
PS Centium<br />
347-480<br />
FT80W/2G11 - 80W (PL-L80W, FT80DL)<br />
1 120-277 PS Centium ICN-1S80<br />
Catalog Number<br />
REL-1TTS50<br />
VEL-1TTS50<br />
ICN-2S54<br />
ICN-2S54-90C<br />
HCN-2S54-90C<br />
REL-2TTS50<br />
VEL-2TTS50<br />
ICN-2S54<br />
ICN-2S54-90C<br />
HCN-2S54-90C<br />
ICN-4S54-90C-2LS<br />
ICN-4S54-90C-2LS-G<br />
HCN-4S54-90C-2LS-G<br />
ICN-4S54-90C-2LS<br />
ICN-4S54-90C-2LS<br />
HCN-4S54-90C-2LS-G<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
51<br />
58<br />
58<br />
100<br />
112-109<br />
112<br />
169-166<br />
178-176<br />
222-217<br />
228-226<br />
91-89<br />
Ballast<br />
Factor<br />
0.85<br />
0.92<br />
0.92<br />
0.84<br />
0.90<br />
0.90<br />
0.90<br />
0.90<br />
0.90<br />
0.90<br />
1.00<br />
Max.<br />
THD<br />
%<br />
20<br />
15<br />
10<br />
20<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
Line<br />
Current<br />
(Amps)<br />
0.43<br />
0.20<br />
0.49-0.22<br />
0.17-0.13<br />
0.83<br />
0.40<br />
0.94-0.41<br />
0.33-0.24<br />
1.41-0.61<br />
0.52-0.37<br />
1.86-0.80<br />
0.66-0.47<br />
0.76-0.33<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
50/10<br />
0/-18<br />
50/10<br />
0/-18<br />
0/-18<br />
0/-18<br />
0/-18<br />
Dim.<br />
A<br />
D<br />
A<br />
D<br />
E<br />
G<br />
E<br />
G<br />
D<br />
Wiring<br />
Dia.<br />
93<br />
73<br />
94<br />
74<br />
*75<br />
75<br />
73<br />
ELECTRONIC<br />
FLUORESCENT<br />
BLACK/WHITE<br />
WHITE<br />
BALLAST<br />
Diag. 70<br />
BLUE<br />
RED<br />
BLACK<br />
WHITE<br />
BALLAST<br />
Diag. 71<br />
BLUE<br />
BLUE<br />
RED<br />
BLACK<br />
WHITE<br />
BLUE<br />
BLUE<br />
BALLAST BLUE<br />
Diag. 72<br />
RED<br />
For 1 lamp operation, do not use yellow leads<br />
Diag. 73<br />
*For 3-lamp operation connect<br />
lamps between RED and<br />
BLUE, BROWN and<br />
BLU/WHT, YELLOW and<br />
BLU/WHT.<br />
LINE<br />
BLK/WHT<br />
WHITE<br />
BALLAST<br />
BLUE<br />
BLUE<br />
RED<br />
RED<br />
Diag. 74 Diag. 75<br />
DIAG. 93<br />
LINE<br />
BLACK<br />
WHITE<br />
YELLOW<br />
YELLOW<br />
BALLAST<br />
BLUE<br />
BLUE<br />
RED<br />
RED<br />
* Note: For 1-lamp operation on 2-lamp ballast, use red and yellow connectors See page 1-36 for Dimensions<br />
DIAG. 94<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-37
2D<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 10 - 21W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
CFS10W/GR10q - 10W 2D Lamp (F10 2D/4P)<br />
ICF-2S13-H1-LD<br />
1<br />
2<br />
120-277<br />
120-277<br />
PS<br />
PS<br />
SmartMate<br />
SmartMate<br />
ICF-2S13-H1-LD-K ➀<br />
ICF-2S13-M1-BS<br />
ICF-2S13-M1-LS<br />
ICF-2S13-H1-LD<br />
ICF-2S13-H1-LD-K ➀<br />
ICF-2S13-M1-BS<br />
ICF-2S13-M1-LS<br />
CFS16W/GR10q - 16W 2D Lamp (F16 2D/4P)<br />
ICF-2S13-H1-LD<br />
1 120-277 PS SmartMate<br />
ICF-2S13-H1-LD-K ➀<br />
ICF-2S13-M1-BS<br />
ICF-2S13-M1-LS<br />
ICF-2S18-H1-LD<br />
2 120-277 PS SmartMate<br />
ICF-2S18-H1-LD-K ➀<br />
ICF-2S18-M1-BS<br />
ICF-2S18-M1-LS<br />
CFS21W/GR10q - 21W 2D Lamp (F21 2D/4P)<br />
ICF-2S18-H1-LD<br />
1 120-277 PS SmartMate<br />
ICF-2S18-H1-LD-K ➀<br />
ICF-2S18-M1-BS<br />
ICF-2S18-M1-LS<br />
ICF-2S18-H1-LD<br />
ICF-2S18-H1-LD-K ➀<br />
ICF-2S18-M1-BS<br />
2 120-277 PS SmartMate<br />
ICF-2S18-M1-LS<br />
ICF-2S26-H1-LD<br />
ICF-2S26-H1-LD-K ➀<br />
ICF-2S26-M1-BS<br />
ICF-2S26-M1-LS<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
13<br />
23<br />
17<br />
37<br />
20<br />
40<br />
51<br />
Ballast<br />
Factor<br />
1.05<br />
0.95<br />
1.00<br />
1.00<br />
0.90<br />
0.91<br />
1.12<br />
Max.<br />
THD<br />
%<br />
15<br />
15<br />
15<br />
10<br />
15<br />
10<br />
10<br />
Line<br />
Current<br />
(Amps)<br />
0.11-0.05<br />
0.19-0.09<br />
0.14-0.06<br />
0.31-0.13<br />
0.16-0.07<br />
0.33-0.14<br />
0.42-0.18<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
0/-18<br />
0/-18<br />
0/-18<br />
0/-18<br />
0/-18<br />
0/-18<br />
Dim.<br />
Size 1<br />
Size 1<br />
Size 1<br />
Size 1<br />
Size 1<br />
Size 1<br />
Wiring<br />
Dia.<br />
160<br />
159<br />
160<br />
159<br />
160<br />
159<br />
➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />
* Note: For 1-lamp operation on 2-lamp ballast, use red and yellow connectors<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-38<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 28 - 38W Lamps<br />
2D<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
CFS28W/GR10q - 28W 2D Lamp (F28 2D/4P)<br />
1<br />
2<br />
120-277<br />
120-277<br />
PS<br />
PS<br />
SmartMate<br />
SmartMate<br />
ICF-1D38-H1-LD<br />
ICF-2S42-M2-BS<br />
ICF-2S42-M2-LD<br />
ICF-2S42-M2-LD-K ➀<br />
ICF-2S42-M2-LS<br />
ICF-2S42-90C-M2-BS<br />
ICF-2S42-90C-M2-LD<br />
ICF-2S42-90C-M2-LS<br />
CFS38W/GR10q - 38W 2D Lamp (F38 2D/4P)<br />
1 120-277 PS SmartMate ICF-1D38-H1-LD<br />
ICF-2S42-M2-BS<br />
ICF-2S42-M2-LD<br />
ICF-2S42-M2-LD-K ➀<br />
2 120-277 PS SmartMate ICF-2S42-M2-LS<br />
ICF-2S42-90C-M2-BS<br />
ICF-2S42-90C-M2-LD<br />
ICF-2S42-90C-M2-LS<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
27<br />
57<br />
57<br />
31<br />
62<br />
62<br />
Ballast<br />
Factor<br />
1.00<br />
1.00<br />
1.00<br />
0.85<br />
0.80<br />
0.80<br />
Max.<br />
THD<br />
%<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
Line<br />
Current<br />
(Amps)<br />
0.23-0.10<br />
0.48-0.21<br />
0.48-0.21<br />
0.26-0.11<br />
0.55-0.23<br />
0.55-0.23<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
0/-18<br />
0/-18<br />
0/-18<br />
0/-18<br />
Dim.<br />
Size 1<br />
Size 2<br />
Size 1<br />
Size 2<br />
Wiring<br />
Dia.<br />
160<br />
159<br />
160<br />
159<br />
ELECTRONIC<br />
FLUORESCENT<br />
➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />
See page 1-38 for Dimensions and Wiring Diagrams<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-39
T5<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 8 - 13W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
F8T5 (8W)<br />
RMB-1P13-L2<br />
10 1.30 150 0.16<br />
1 120 IS Matchbox † RMB-1P13-S1<br />
0/-18<br />
RMB-2P13-L2<br />
19 1.30 125 0.27<br />
2 120 IS Matchbox † RMB-2P13-S2<br />
0/-18<br />
RMB-1P13-S2-H<br />
10 1.20 20 0.08<br />
RMB-2P13-S3-H<br />
19 1.25 10 0.16<br />
(1) F8T5 & (1) F13T5 {(1) 8W & (1) 13W}<br />
RMB-2P13-L2<br />
23 1.10 125 0.33<br />
1 120 IS Matchbox † RMB-2P13-S2<br />
0/-18<br />
RMB-2P13-S3-H<br />
23 1.10 10 0.20<br />
F13T5 (13W)<br />
RMB-1P13-L2<br />
14 1.00 150 0.21<br />
1 120 IS Matchbox † RMB-1P13-S1<br />
0/-18<br />
RMB-2P13-L2<br />
27 0.95 125 0.38<br />
2 120 IS Matchbox † RMB-2P13-S2<br />
0/-18<br />
RMB-1P13-S2-H<br />
14 0.95 15 0.12<br />
RMB-2P13-S3-H<br />
28 0.95 10 0.24<br />
Max.<br />
THD<br />
%<br />
Line<br />
Current<br />
(Amps)<br />
Dim.<br />
L2<br />
S1<br />
S2<br />
L2<br />
S2<br />
S3<br />
L2<br />
S1<br />
S2<br />
L2<br />
S1<br />
S2<br />
L2<br />
S2<br />
S3<br />
Wiring<br />
Dia.<br />
163<br />
162<br />
162<br />
163<br />
162<br />
† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />
S1 Model<br />
1.05"<br />
8.91"<br />
9.50"<br />
Fig. A2<br />
1.08"<br />
Fig. D<br />
L2 Model<br />
S2 Model<br />
S3 Model<br />
1 or 2 lamp linear ballast, plastic enclosure<br />
See page 1-41 for Wiring Diagrams<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-40<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 14 - 35W Lamps<br />
T5<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
F14T5 (14W)<br />
1<br />
2<br />
120<br />
120-277<br />
120-277<br />
3 120-277<br />
F21T5 (21W)<br />
1<br />
2<br />
1<br />
2<br />
Input<br />
Volts<br />
120<br />
120-277<br />
120-277<br />
120-277<br />
F28T5 (28W)<br />
120-277<br />
120-277<br />
F35T5 (35W)<br />
1 120-277<br />
2 120-277<br />
Lamp<br />
Starting<br />
Method<br />
IS<br />
PS<br />
IS<br />
PS<br />
PS<br />
PS<br />
IS<br />
PS<br />
IS<br />
PS<br />
IS<br />
PS<br />
IS<br />
PS<br />
PS<br />
PS<br />
Ballast<br />
Family<br />
Matchbox †<br />
Centium<br />
Matchbox †<br />
Centium<br />
Centium<br />
Centium<br />
Centium<br />
Centium<br />
Centium<br />
Centium<br />
Centium<br />
Centium<br />
Catalog Number<br />
RMB-1P13-L2<br />
RMB-1P13-S1<br />
RMB-1P13-S2-H<br />
ICN-132-MC<br />
ICN-2S28<br />
RMB-2P13-L2<br />
RMB-2P13-S2<br />
RMB-2P13-S3-H<br />
ICN-2M32-MC<br />
ICN-2S28<br />
ICN-3S14-D<br />
ICN-3S14-D<br />
ICN-132-MC<br />
ICN-2S28<br />
ICN-2M32-MC<br />
ICN-2S28<br />
ICN-132-MC<br />
ICN-2S28<br />
ICN-2M32-MC<br />
ICN-2S28<br />
ICN-2S28<br />
ICN-2S28<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
14<br />
14<br />
19<br />
19<br />
27<br />
28<br />
36<br />
34<br />
36<br />
50<br />
26<br />
26<br />
50<br />
48<br />
34<br />
33<br />
68<br />
64-63<br />
41<br />
80-77<br />
Ballast<br />
Factor<br />
0.95<br />
0.90<br />
1.05<br />
1.07<br />
0.90<br />
0.90<br />
1.05<br />
1.06<br />
1.10<br />
1.00<br />
1.05<br />
1.03<br />
1.05<br />
1.02<br />
1.05<br />
1.04<br />
1.05<br />
1.03<br />
1.01<br />
1.00<br />
Max.<br />
THD<br />
%<br />
150<br />
15<br />
20<br />
20<br />
125<br />
10<br />
20<br />
10<br />
10<br />
10<br />
15<br />
15<br />
15<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
Line<br />
Current<br />
(Amps)<br />
0.21<br />
0.12<br />
0.15-0.07<br />
0.16-0.07<br />
0.40<br />
0.24<br />
0.30-0.13<br />
0.29-0.13<br />
0.31-0.13<br />
0.42-0.18<br />
0.21-0.09<br />
0.21-0.10<br />
0.42-0.18<br />
0.40-0.17<br />
0.28-0.12<br />
0.28-0.12<br />
0.57-0.25<br />
0.55-0.23<br />
0.34-0.15<br />
0.67-0.28<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
0/-18<br />
32/0<br />
0/-18<br />
32/0<br />
0/-18<br />
32/0<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
0/-18<br />
Dim.<br />
L2<br />
S1<br />
S2<br />
A2<br />
D<br />
L2<br />
S2<br />
S3<br />
A2<br />
D<br />
D<br />
D<br />
A2<br />
D<br />
A2<br />
D<br />
A2<br />
D<br />
A2<br />
D<br />
D<br />
D<br />
Wiring<br />
Dia.<br />
163<br />
63<br />
73<br />
162<br />
64<br />
74<br />
172<br />
171<br />
63<br />
73<br />
64<br />
74<br />
63<br />
73<br />
64<br />
74<br />
73<br />
74<br />
ELECTRONIC<br />
FLUORESCENT<br />
† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />
See page 1-40 for Dimensions<br />
WHITE<br />
BLACK<br />
BALLAST<br />
BLUE<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
BLUE<br />
BLUE<br />
RED<br />
LAMP<br />
LINE<br />
LAMP<br />
LINE<br />
LAMP<br />
For 1 lamp operation, do not use yellow leads<br />
Diag. 73<br />
Diag. 63<br />
Diag. 64<br />
* For Single Lamp Operation, insulate unused<br />
blue lead for 600 volts<br />
Diag. 74<br />
* Note: For 1-lamp operation on 2-lamp ballast, use red and yellow connectors<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-41
T5 and T5/HO<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 22 - 55W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
FC9T5 (22W Circline)<br />
120 IS<br />
1<br />
2<br />
Input<br />
Volts<br />
120-277<br />
120-277<br />
Lamp<br />
Starting<br />
Method<br />
PS<br />
PS<br />
Ballast<br />
Family<br />
Matchbox †<br />
SmartMate<br />
Centium<br />
Centium<br />
Catalog Number<br />
RMB-1P26-S2<br />
ICF-1D38-H1-LD<br />
ICN-2S24<br />
ICN-2S39<br />
ICN-2S24<br />
ICN-2S39<br />
FC12T5 (40W Circline)<br />
SmartMate ICF-1D38-H1-LD<br />
1 120-277 PS<br />
ICN-2S24<br />
Centium<br />
ICN-2S39<br />
2 120-277 PS Centium ICN-2S39<br />
(1) FC9T5 & (1) FC12T5 {(1) 22W & (1) 40W Circline}<br />
ICF-2S42-M2-BS<br />
ICF-2S42-M2-LD<br />
ICF-2S42-M2-LD-K ➀<br />
1&1 120-277 PS<br />
SmartMate ICF-2S42-M2-LS<br />
ICF-2S42-90C-M2-BS<br />
ICF-2S42-90C-M2-LD<br />
ICF-2S42-90C-M2-LS<br />
Centium ICN-2S39<br />
FC12T5/HO (55W Circline)<br />
ICN-2S54<br />
120-277<br />
1<br />
PS Centium ICN-2S54-90C<br />
347-480<br />
HCN-2S54-90C<br />
ICN-2S54<br />
120-277<br />
2<br />
PS Centium ICN-2S54-90C<br />
347-480<br />
HCN-2S54-90C<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
25<br />
25<br />
27<br />
29<br />
52<br />
54<br />
38<br />
40<br />
42<br />
80<br />
61<br />
68<br />
1.00<br />
1.00<br />
1.02<br />
1.12<br />
1.00<br />
1.10<br />
0.95<br />
0.84<br />
0.92<br />
0.90<br />
0.85<br />
1.00<br />
150<br />
15<br />
10<br />
15<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
61 0.85 10<br />
55<br />
55<br />
106-103<br />
106<br />
Ballast<br />
Factor<br />
0.87<br />
0.87<br />
0.85<br />
0.85<br />
Max.<br />
THD<br />
%<br />
10<br />
15<br />
10<br />
10<br />
10<br />
Line<br />
Current<br />
(Amps)<br />
0.39<br />
0.21-0.09<br />
0.23-0.10<br />
0.24-0.12<br />
0.44-0.19<br />
0.46-0.20<br />
0.32-0.14<br />
0.34-0.15<br />
0.35-0.16<br />
0.68-0.29<br />
0.51-0.22<br />
0.51-0.22<br />
0.58-0.25<br />
0.46-0.21<br />
0.16-0.12<br />
0.89-0.38<br />
0.31-0.22<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
0/-18<br />
0/-18<br />
0/-18<br />
0/-18<br />
0/-18<br />
0/-18<br />
0/-18<br />
Dim.<br />
S2<br />
Size 1<br />
D<br />
D<br />
Size 1<br />
D<br />
D<br />
Size 1<br />
D<br />
163<br />
73<br />
74<br />
163<br />
73<br />
74<br />
162<br />
Size 1 162<br />
D<br />
D<br />
Wiring<br />
Dia.<br />
74<br />
73<br />
74<br />
† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />
➀ Replacement/Retrofit ballast kits indicated by Bold Type with suffix K are available to distributors. Refer to page 1-24 for details.<br />
For 1 lamp operation, do not use yellow leads<br />
Diag. 73<br />
Diag. 74<br />
Diag. 75<br />
*For 3-lamp operation connect<br />
lamps between RED and<br />
BLUE, BROWN and<br />
BLU/WHT, YELLOW and<br />
BLU/WHT.<br />
* Note: For 1-lamp operation on 2-lamp ballast, use red and yellow connectors See page 1-43 for Dimensions<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-42<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 24 - 80W Lamps<br />
T5/HO<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
F24T5/HO (24W)<br />
1<br />
2<br />
1<br />
120-277<br />
120-277<br />
F39T5/HO (39W)<br />
2 120-277<br />
F54T5/HO (54W)<br />
1<br />
2<br />
3<br />
Input<br />
Volts<br />
120-277<br />
120-277<br />
347-480<br />
120-277<br />
347-480<br />
120-277<br />
347-480<br />
120-277<br />
4<br />
347-480<br />
F80T5/HO (80W)<br />
1 120-277<br />
Lamp<br />
Starting<br />
Method<br />
PS<br />
PS<br />
PS<br />
PS<br />
PS<br />
PS<br />
PS<br />
PS<br />
PS<br />
Ballast<br />
Family<br />
Centium<br />
Centium<br />
Centium<br />
Centium<br />
Centium<br />
Centium<br />
Centium<br />
Centium<br />
Centium<br />
Catalog Number<br />
ICN-2S24<br />
ICN-2S39<br />
ICN-2S24<br />
ICN-2S39<br />
ICN-2S24<br />
ICN-2S39<br />
ICN-2S39<br />
ICN-2S54<br />
ICN-2S54-90C<br />
HCN-2S54-90C<br />
ICN-2S54<br />
ICN-2S54-90C<br />
HCN-2S54-90C<br />
ICN-4S54-90C-2LS<br />
ICN-4S54-90C-2LS-G<br />
HCN-4S54-90C-2LS-G<br />
ICN-4S54-90C-2LS<br />
ICN-4S54-90C-2LS-G<br />
HCN-4S54-90C-2LS-G<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
27<br />
29<br />
52<br />
55<br />
40<br />
43<br />
87-85<br />
62<br />
185<br />
120-117<br />
120-119<br />
182-179<br />
182-179<br />
188-186<br />
240-234<br />
240-234<br />
239-237<br />
Ballast<br />
Factor<br />
1.02<br />
1.12<br />
1.00<br />
1.10<br />
0.90<br />
1.02<br />
1.00<br />
1.02<br />
0.95<br />
1.00<br />
1.00<br />
1.00<br />
1.00<br />
1.04<br />
1.00<br />
1.00<br />
1.00<br />
Max.<br />
THD<br />
%<br />
0.23-0.10<br />
0.25-0.12<br />
0.44-0.19<br />
0.47-0.21<br />
0/-18<br />
0/-18<br />
0/-18<br />
0/-18<br />
-20/-29<br />
0/-18<br />
-20/-29<br />
0/-18<br />
0/-18<br />
0/-18<br />
ICN-1S80 91-89 1.00 10 0.76-0.33 0/-18 D<br />
10<br />
15<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
Line<br />
Current<br />
(Amps)<br />
0.34-0.15<br />
0.36-0.16<br />
0.73-0.31<br />
0.52-0.23<br />
0.18-0.13<br />
1.00-0.43<br />
0.35-0.25<br />
1.52-0.66<br />
1.52-0.66<br />
0.54-0.39<br />
2.00-0.86<br />
2.00-0.86<br />
0.69-0.50<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
D<br />
D<br />
D<br />
D<br />
D<br />
D<br />
D<br />
G<br />
D<br />
G<br />
Wiring<br />
Dia.<br />
73<br />
74<br />
73<br />
74<br />
73<br />
74<br />
*75<br />
75<br />
73<br />
ELECTRONIC<br />
FLUORESCENT<br />
S2 Model<br />
Fig. D<br />
Fig. G<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
See page 1-42 for Wiring Diagrams<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-43
T8<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 17W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
1<br />
Input<br />
Volts<br />
120<br />
277<br />
120-277<br />
Lamp<br />
Starting<br />
Method<br />
F17T8, FBO16T8 (17W)<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
Ballast<br />
Family<br />
AmbiStar ‡<br />
Standard<br />
Centium<br />
Optanium<br />
Standard<br />
Centium<br />
Optanium<br />
Centium<br />
Optanium<br />
Mark 5<br />
Catalog Number<br />
REB-2P32-SC<br />
REL-1P32-LW-SC<br />
REL-1P32-SC<br />
REL-1P32-HL-SC<br />
REL-2P17-RH-TP<br />
RCN-1S32-SC<br />
ROP-2P32-LW-SC<br />
ROP-2P32-SC<br />
VEL-1P32-LW-SC<br />
VEL-1P32-SC<br />
VEL-1P32-HL-SC<br />
VEL-2P17-RH-TP<br />
VCN-1S32-SC<br />
VOP-2P32-LW-SC<br />
VOP-2P32-SC<br />
ICN-132-MC<br />
ICN-1P32-LW-SC<br />
ICN-1P32-SC<br />
ICN-2P32-LW-SC<br />
ICN-2P32-SC<br />
IOP-1P32-LW-SC<br />
IOP-1P32-SC<br />
IOP-1P32-HL-SC<br />
IOP-2P32-LW-SC<br />
IOP-2P32-SC<br />
IOP-2P32-HL-SC<br />
IOP-1S32-LW-SC<br />
IOP-1S32-SC<br />
IOP-2S32-LW-SC<br />
IOP-2S32-SC<br />
IIC-132-SC<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
19 1.02 150<br />
18<br />
20<br />
24<br />
22<br />
22<br />
17<br />
19<br />
18<br />
20<br />
24<br />
22<br />
22<br />
17<br />
19<br />
17<br />
16<br />
19<br />
19<br />
22<br />
15<br />
16<br />
22<br />
18<br />
19<br />
25<br />
14<br />
16<br />
15<br />
17<br />
18<br />
Ballast<br />
Factor<br />
0.87<br />
0.95<br />
1.22<br />
1.15<br />
1.00<br />
0.89<br />
1.02<br />
0.87<br />
0.95<br />
1.22<br />
1.15<br />
1.00<br />
0.89<br />
1.02<br />
0.88<br />
0.80<br />
0.93<br />
0.90<br />
1.07<br />
0.80<br />
0.90<br />
1.23<br />
0.90<br />
1.06<br />
1.42<br />
0.79<br />
0.97<br />
0.78<br />
0.97<br />
0.88<br />
Max.<br />
THD<br />
%<br />
25<br />
30<br />
20<br />
25<br />
10<br />
20<br />
15<br />
25<br />
30<br />
20<br />
25<br />
10<br />
20<br />
15<br />
20<br />
10<br />
15<br />
20<br />
15<br />
10<br />
10<br />
15<br />
20<br />
15<br />
20<br />
10<br />
10<br />
15<br />
15<br />
15<br />
Line<br />
Current<br />
(Amps)<br />
0.30<br />
0.17<br />
0.19<br />
0.21<br />
0.19<br />
0.19<br />
0.15<br />
0.17<br />
0.08<br />
0.08<br />
0.10<br />
0.09<br />
0.08<br />
0.07<br />
0.08<br />
0.14-0.06<br />
0.13-0.06<br />
0.16-0.07<br />
0.16-0.07<br />
0.18-0.09<br />
0.13-0.06<br />
0.14-0.07<br />
0.19-0.08<br />
0.15-0.07<br />
0.17-0.08<br />
0.21-0.10<br />
0.12-0.05<br />
0.14-0.07<br />
0.12-0.06<br />
0.14-0.07<br />
0.15-0.07<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
Dim.<br />
B<br />
A<br />
B<br />
B<br />
A<br />
B<br />
A2<br />
B<br />
Wiring<br />
Dia.<br />
*64<br />
63<br />
*64<br />
20<br />
*64<br />
63<br />
*64<br />
20<br />
*64<br />
63<br />
*64<br />
63<br />
*64<br />
20<br />
39<br />
20<br />
‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />
See page 1-47 for Wiring Diagrams<br />
1.18"<br />
8.90"<br />
9.5"<br />
Fig. A<br />
1.7"<br />
Fig. B<br />
1.05"<br />
8.91"<br />
9.50"<br />
Fig. G<br />
1.08"<br />
Fig. A2<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-44<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 17W Lamps<br />
T8<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
2<br />
Input<br />
Volts<br />
120<br />
277<br />
120-277<br />
347<br />
Lamp<br />
Starting<br />
Method<br />
F17T8, FBO16T8 (17W)<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
Ballast<br />
Family<br />
AmbiStar ‡<br />
Standard<br />
Centium<br />
Optanium<br />
Standard<br />
Centium<br />
Optanium<br />
Centium<br />
Optanium<br />
Optanium<br />
Mark 5<br />
Standard<br />
Catalog Number<br />
REB-2P32-SC<br />
REL-2P17-RH-TP<br />
REL-2P32-LW-SC<br />
REL-2P32-SC<br />
REL-2P32-HL-SC<br />
REL-3P32-LW-SC<br />
RCN-2S32-SC<br />
ROP-2P32-LW-SC<br />
ROP-2P32-SC<br />
ROP-3P32-LW-SC<br />
ROP-3P32-SC<br />
VEL-2P17-RH-TP<br />
VEL-2P32-LW-SC<br />
VEL-2P32-SC<br />
VEL-2P32-HL-SC<br />
VEL-3P32-LW-SC<br />
VCN-2S32-SC<br />
VOP-2P32-LW-SC<br />
VOP-2P32-SC<br />
VOP-3P32-LW-SC<br />
VOP-3P32-SC<br />
ICN-2M32-MC<br />
ICN-2P32-LW-SC<br />
ICN-2P32-SC<br />
ICN-3P32-LW-SC<br />
ICN-3P32-SC<br />
IOP-2P32-LW-SC<br />
IOP-2P32-SC<br />
IOP-2P32-HL-SC<br />
IOP-3P32-LW-SC<br />
IOP-3P32-SC<br />
IOP-3P32-HL-90C-SC<br />
IOP-2S32-LW-SC<br />
IOP-2S32-SC<br />
IIC-2S32-SC<br />
GEL-2P32-LW-RH-TP<br />
GEL-2P32-SC<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
31<br />
34<br />
30<br />
34<br />
43<br />
34<br />
39<br />
27<br />
31<br />
29<br />
35<br />
34<br />
30<br />
34<br />
43<br />
34<br />
39<br />
27<br />
31<br />
29<br />
35<br />
31<br />
28<br />
33<br />
32<br />
38<br />
27<br />
31<br />
41<br />
31<br />
35<br />
47<br />
25<br />
29<br />
33<br />
31<br />
34<br />
Ballast<br />
Factor<br />
0.91<br />
0.98<br />
0.82<br />
0.98<br />
1.26<br />
0.87<br />
1.00<br />
0.80<br />
0.90<br />
0.87<br />
0.97<br />
0.98<br />
0.82<br />
0.98<br />
1.26<br />
0.87<br />
1.00<br />
0.80<br />
0.90<br />
0.87<br />
0.97<br />
0.88<br />
0.79<br />
0.93<br />
0.88<br />
1.07<br />
0.80<br />
0.90<br />
0.87<br />
0.87<br />
1.01<br />
1.37<br />
0.73<br />
0.90<br />
0.88<br />
0.82<br />
0.92<br />
Max.<br />
THD<br />
%<br />
140<br />
20<br />
30<br />
30<br />
20<br />
20<br />
10<br />
10<br />
10<br />
15<br />
15<br />
20<br />
30<br />
30<br />
20<br />
20<br />
10<br />
15<br />
15<br />
20<br />
15<br />
10<br />
20<br />
15<br />
20<br />
15<br />
10<br />
10<br />
15<br />
20<br />
15<br />
10-30<br />
10<br />
15<br />
15<br />
30<br />
30<br />
Line<br />
Current<br />
(Amps)<br />
0.45<br />
0.29<br />
0.29<br />
0.29<br />
0.36<br />
0.28<br />
0.33<br />
0.23<br />
0.26<br />
0.25<br />
0.30<br />
0.13<br />
0.12<br />
0.13<br />
0.16<br />
0.13<br />
0.15<br />
0.10<br />
0.11<br />
0.12<br />
0.14<br />
0.26-0.11<br />
0.23-0.10<br />
0.28-0.13<br />
0.27-0.18<br />
0.32-0.14<br />
0.23-0.10<br />
0.26-0.11<br />
0.34-0.15<br />
0.26-0.12<br />
0.30-0.14<br />
0.39-0.20<br />
0.21-0.09<br />
0.24-0.11<br />
0.27-0.12<br />
0.09<br />
0.11<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
0/-18<br />
Dim.<br />
B<br />
A<br />
B<br />
A<br />
B<br />
A2<br />
B<br />
A<br />
B<br />
Wiring<br />
Dia.<br />
*64<br />
64<br />
*65<br />
21<br />
64<br />
*65<br />
64<br />
*65<br />
21<br />
64<br />
*65<br />
64<br />
*65<br />
64<br />
*65<br />
21<br />
64<br />
ELECTRONIC<br />
FLUORESCENT<br />
‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />
See page 1-44 for Dimensions<br />
See page 1-47 for Wiring Diagrams<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-45
T8<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 17W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
3<br />
Input<br />
Volts<br />
120<br />
277<br />
120-277<br />
347<br />
Lamp<br />
Starting<br />
Method<br />
F17T8, FBO16T8 (17W)<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
RS<br />
Ballast<br />
Family<br />
AmbiStar ‡<br />
Standard<br />
Centium<br />
Optanium<br />
Standard<br />
Centium<br />
Optanium<br />
Centium<br />
Optanium<br />
Optanium<br />
Mark 5<br />
Centium<br />
Catalog Number<br />
REB-4P32-SC<br />
REL-3P32-LW-SC<br />
REL-3P32-SC<br />
REL-3P32-HL-SC<br />
REL-4P32-LW-SC<br />
RCN-3S32-SC<br />
ROP-3P32-LW-SC<br />
ROP-3P32-SC<br />
ROP-4P32-LW-SC<br />
ROP-4P32-SC<br />
ROP-4P32-HL-90C<br />
VEL-3P32-LW-SC<br />
VEL-3P32-SC<br />
VEL-3P32-HL-SC<br />
VEL-4P32-LW-SC<br />
VCN-3S32-SC<br />
VOP-3P32-LW-SC<br />
VOP-3P32-SC<br />
VOP-4P32-LW-SC<br />
VOP-4P32-SC<br />
VOP-4P32-HL-90C<br />
ICN-3P32-LW-SC<br />
ICN-3P32-SC<br />
ICN-4P32-LW-SC<br />
ICN-4P32-SC<br />
IOP-3P32-LW-SC<br />
IOP-3P32-SC<br />
IOP-3P32-HL-90C-SC<br />
IOP-4P32-LW-SC<br />
IOP-4P32-SC<br />
IOP-4P32-HL-90C-G<br />
IOP-3S32-LW-SC<br />
IOP-3S32-SC<br />
IIC-3S32-SC<br />
GCN-3S32<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
44<br />
44<br />
47<br />
61<br />
47<br />
61<br />
39<br />
45<br />
41<br />
49<br />
65<br />
44<br />
47<br />
61<br />
47<br />
61<br />
39<br />
45<br />
41<br />
49<br />
61<br />
42<br />
48<br />
43<br />
53<br />
40<br />
45<br />
59<br />
43<br />
49<br />
69<br />
37<br />
43<br />
50<br />
64<br />
Ballast<br />
Factor<br />
0.81<br />
0.77<br />
0.99<br />
1.22<br />
0.84<br />
1.00<br />
0.80<br />
0.91<br />
0.85<br />
0.95<br />
1.25<br />
0.77<br />
0.99<br />
1.22<br />
0.84<br />
1.00<br />
0.80<br />
0.91<br />
0.85<br />
0.95<br />
1.25<br />
0.80<br />
0.92<br />
0.85<br />
1.04<br />
0.81<br />
0.90<br />
1.22<br />
0.85<br />
1.00<br />
1.28<br />
0.72<br />
0.89<br />
0.88<br />
1.04<br />
Max.<br />
THD<br />
%<br />
135<br />
20<br />
20<br />
20<br />
20<br />
10<br />
10<br />
10<br />
15<br />
15<br />
15<br />
20<br />
20<br />
20<br />
20<br />
10<br />
15<br />
15<br />
15<br />
15<br />
15<br />
15<br />
15<br />
15<br />
15<br />
10<br />
10<br />
10-15<br />
20<br />
15<br />
10-15<br />
10<br />
10<br />
15<br />
30<br />
Line<br />
Current<br />
(Amps)<br />
0.87<br />
0.37<br />
0.39<br />
0.51<br />
0.39<br />
0.51<br />
0.33<br />
0.38<br />
0.35<br />
0.41<br />
0.55<br />
0.16<br />
0.17<br />
0.23<br />
0.17<br />
0.22<br />
0.15<br />
0.17<br />
0.16<br />
0.18<br />
0.24<br />
0.35-0.16<br />
0.39-0.17<br />
0.36-0.16<br />
0.45-0.20<br />
0.34-0.15<br />
0.38-0.17<br />
0.49-0.22<br />
0.36-0.17<br />
0.41-0.18<br />
0.58-0.26<br />
0.31-0.14<br />
0.36-0.16<br />
0.41-0.19<br />
0.19<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
32/0<br />
Dim.<br />
B<br />
A<br />
B<br />
A<br />
B<br />
G<br />
B<br />
A<br />
Wiring<br />
Dia.<br />
*66<br />
65<br />
*66<br />
30<br />
65<br />
*66<br />
65<br />
*66<br />
30<br />
65<br />
*66<br />
65<br />
*66<br />
65<br />
*66<br />
30<br />
30<br />
‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />
See page 1-44 for Dimensions<br />
See page 1-47 for Wiring Diagrams<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-46<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 17W Lamps<br />
T8<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
4<br />
Input<br />
Volts<br />
F17T8, FBO16T8 (17W)<br />
120<br />
277<br />
120-277<br />
347<br />
Lamp<br />
Starting<br />
Method<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
Ballast<br />
Family<br />
AmbiStar ‡<br />
Standard<br />
Centium<br />
Optanium<br />
Standard<br />
Centium<br />
Optanium<br />
Centium<br />
Optanium<br />
Optanium<br />
Standard<br />
Catalog Number<br />
REB-4P32-SC<br />
REL-4P32-LW-SC<br />
REL-4P32-SC<br />
RCN-4S32-SC<br />
ROP-4P32-SC<br />
ROP-4P32-LW-SC<br />
ROP-4P32-HL-90C<br />
VEL-4P32-LW-SC<br />
VEL-4P32-SC<br />
VCN-4S32-SC<br />
VOP-4P32-LW-SC<br />
VOP-4P32-SC<br />
VOP-4P32-HL-90C<br />
ICN-4P32-LW-SC<br />
ICN-4P32-SC<br />
IOP-4P32-LW-SC<br />
IOP-4P32-SC<br />
IOP-4P32-HL-90C-G<br />
IOP-4S32-LW-SC<br />
IOP-4S32-SC<br />
GEL-4P32-LW<br />
GEL-4P32-RH-TP<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
52<br />
54<br />
61<br />
79<br />
58<br />
50<br />
77<br />
54<br />
61<br />
79<br />
50<br />
58<br />
77<br />
53<br />
64<br />
53<br />
58<br />
79<br />
48<br />
57<br />
54<br />
56<br />
Ballast<br />
Factor<br />
0.82<br />
0.77<br />
0.96<br />
1.00<br />
0.90<br />
0.80<br />
1.18<br />
0.77<br />
0.96<br />
1.00<br />
0.80<br />
0.90<br />
1.18<br />
0.79<br />
0.93<br />
0.81<br />
0.90<br />
1.22<br />
0.72<br />
0.89<br />
0.77<br />
0.88<br />
Max.<br />
THD<br />
%<br />
135<br />
20<br />
20<br />
10<br />
10<br />
10<br />
10<br />
20<br />
20<br />
10<br />
15<br />
15<br />
10<br />
15<br />
10<br />
10<br />
10<br />
10-15<br />
10<br />
10<br />
30<br />
30<br />
Line<br />
Current<br />
(Amps)<br />
1.00<br />
0.46<br />
0.51<br />
0.67<br />
0.49<br />
0.43<br />
0.65<br />
0.20<br />
0.22<br />
0.29<br />
0.19<br />
0.22<br />
0.28<br />
0.44-0.19<br />
0.54-0.23<br />
0.45-0.20<br />
0.49-0.22<br />
0.66-0.29<br />
0.40-0.18<br />
0.47-0.21<br />
0.18<br />
0.18<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
0/-18<br />
Dim.<br />
B<br />
A<br />
B<br />
A<br />
B<br />
G<br />
B<br />
A<br />
Wiring<br />
Dia.<br />
*66<br />
66<br />
138<br />
66<br />
66<br />
138<br />
66<br />
66<br />
138<br />
66<br />
ELECTRONIC<br />
FLUORESCENT<br />
‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />
LAMP<br />
LAMP<br />
LAMP<br />
LAMP<br />
LINE<br />
RED<br />
RED<br />
BLUE/WHITE<br />
BLUE/WHITE<br />
BLACK<br />
WHITE<br />
BALLAST<br />
Diag. 30<br />
YELLOW<br />
YELLOW<br />
BLUE<br />
BLUE<br />
LINE<br />
* YEL<br />
BLUE<br />
* YEL<br />
BLUE<br />
BALLAST<br />
WHITE<br />
RED<br />
BLACK<br />
RED<br />
*FOR SINGLE LAMP OPERATION, INSULATE<br />
YELLOW LEADS INDIVIDUALLY FOR 600V<br />
Diag. 39<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
BLUE<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
BLUE<br />
BLUE<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
BLUE<br />
BLUE<br />
BLUE<br />
LINE<br />
LAMP<br />
LINE<br />
LAMP<br />
LAMP<br />
LINE<br />
LAMP<br />
LAMP<br />
Diag. 63<br />
Diag. 64<br />
* For Single Lamp Operation, insulate unused<br />
blue lead for 600 volts<br />
LAMP<br />
Diag. 65<br />
* For Two Lamp Operation, insulate unused<br />
blue lead for 600 volts<br />
WHITE<br />
BLACK<br />
YELLOW<br />
YELLOW<br />
BALLAST<br />
BLUE<br />
BLUE<br />
RED<br />
RED<br />
LAMP<br />
LAMP<br />
LINE<br />
LAMP<br />
LAMP<br />
Diag. 66<br />
* For Three Lamp Operation, insulate unused<br />
blue lead for 600 volts<br />
Diag. 138<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
See page 1-44 for Dimensions<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-47
T8<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 25W - 36" Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
1<br />
Input<br />
Volts<br />
F25T8, FBO24T8 (25W - 36")<br />
AmbiStar ‡<br />
120<br />
277<br />
120-277<br />
347<br />
Lamp<br />
Starting<br />
Method<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
RS<br />
Ballast<br />
Family<br />
Standard<br />
Centium<br />
Optanium<br />
Standard<br />
Centium<br />
Optanium<br />
Centium<br />
Optanium<br />
Mark 5<br />
Standard<br />
Centium<br />
Catalog Number<br />
REB-2P32-SC<br />
REL-1P32-LW-SC<br />
REL-1P32-SC<br />
REL-1P32-HL-SC<br />
REL-2P32-SC<br />
REL-2P32-HL-SC<br />
RCN-1S32-SC<br />
ROP-2P32-LW-SC<br />
ROP-2P32-SC<br />
VEL-1P32-LW-SC<br />
VEL-1P32-SC<br />
VEL-1P32-HL-SC<br />
VEL-2P32-SC<br />
VEL-2P32-HL-SC<br />
VCN-1S32-SC<br />
VOP-2P32-LW-SC<br />
VOP-2P32-SC<br />
ICN-132-MC<br />
ICN-1P32-LW-SC<br />
ICN-1P32-SC<br />
ICN-2P32-LW-SC<br />
ICN-2P32-SC<br />
IOP-1P32-LW-SC<br />
IOP-1P32-SC<br />
IOP-1P32-HL-SC<br />
IOP-2P32-LW-SC<br />
IOP-2P32-SC<br />
IOP-2P32-HL-SC<br />
IOP-1S32-LW-SC<br />
IOP-1S32-SC<br />
IOP-2S32-LW-SC<br />
IOP-2S32-SC<br />
IIC-132-SC<br />
GEL-2P32-SC<br />
GCN-2P32<br />
GCN-1S32<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
26<br />
24<br />
24<br />
33<br />
30<br />
38<br />
28<br />
24<br />
27<br />
24<br />
24<br />
33<br />
30<br />
38<br />
28<br />
24<br />
27<br />
23<br />
22<br />
26<br />
25<br />
29<br />
21<br />
23<br />
30<br />
24<br />
28<br />
35<br />
20<br />
22<br />
20<br />
23<br />
25<br />
28<br />
32<br />
31<br />
Ballast<br />
Factor<br />
1.00<br />
0.82<br />
0.92<br />
1.21<br />
1.04<br />
1.43<br />
0.95<br />
0.88<br />
1.02<br />
0.82<br />
0.92<br />
1.21<br />
1.10<br />
1.43<br />
0.95<br />
0.88<br />
1.02<br />
0.88<br />
0.80<br />
0.91<br />
0.88<br />
1.06<br />
0.78<br />
0.88<br />
1.22<br />
0.90<br />
1.05<br />
1.40<br />
0.74<br />
0.92<br />
0.73<br />
0.90<br />
0.88<br />
0.92<br />
1.17<br />
0.97<br />
Max.<br />
THD<br />
%<br />
150<br />
20<br />
25<br />
20<br />
30<br />
20<br />
10<br />
15<br />
15<br />
20<br />
25<br />
20<br />
30<br />
20<br />
10<br />
15<br />
15<br />
15<br />
15<br />
10<br />
20<br />
15<br />
10<br />
10<br />
10<br />
10<br />
10<br />
20<br />
10<br />
10<br />
15<br />
15<br />
10<br />
25<br />
25<br />
20<br />
Line<br />
Current<br />
(Amps)<br />
0.39<br />
0.21<br />
0.21<br />
0.28<br />
0.29<br />
0.32<br />
0.24<br />
0.20<br />
0.23<br />
0.09<br />
0.09<br />
0.13<br />
0.13<br />
0.14<br />
0.10<br />
0.09<br />
0.10<br />
0.19-0.09<br />
0.18-0.08<br />
0.22-0.10<br />
0.21-0.10<br />
0.24-0.11<br />
0.17-0.08<br />
0.20-0.09<br />
0.26-0.11<br />
0.20-0.09<br />
0.23-0.10<br />
0.29-0.13<br />
0.16-0.07<br />
0.19-0.08<br />
0.17-0.08<br />
0.19-0.09<br />
0.21-0.09<br />
0.09<br />
0.10<br />
0.09<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
0/-18<br />
32/0<br />
Dim.<br />
B<br />
B<br />
A2<br />
B<br />
B<br />
A<br />
Wiring<br />
Dia.<br />
*64<br />
63<br />
*64<br />
20<br />
*64<br />
63<br />
*64<br />
20<br />
*64<br />
63<br />
*64<br />
63<br />
*64<br />
20<br />
39<br />
20<br />
*64<br />
20<br />
‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />
See page 1-51 for Wiring Diagrams<br />
1.18"<br />
8.90"<br />
9.5"<br />
Fig. A<br />
1.7"<br />
Fig. B<br />
1.05"<br />
8.91"<br />
9.50"<br />
Fig. G<br />
1.08"<br />
Fig. A2<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-48<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 25W - 36" Lamps<br />
T8<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
2<br />
Input<br />
Volts<br />
F25T8, FBO24T8 (25W - 36")<br />
AmbiStar ‡<br />
120<br />
277<br />
120-277<br />
347<br />
Lamp<br />
Starting<br />
Method<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
IS<br />
RS<br />
Ballast<br />
Family<br />
Standard<br />
Centium<br />
Optanium<br />
Standard<br />
Centium<br />
Optanium<br />
Centium<br />
Optanium<br />
Mark 5<br />
Standard<br />
Centium<br />
Catalog Number<br />
REB-2P32-SC<br />
REL-2P32-LW-SC<br />
REL-2P32-SC<br />
REL-2P32-HL-SC<br />
REL-3P32-LW-SC<br />
REL-3P32-SC<br />
REL-3P32-HL-SC<br />
RCN-2S32-SC<br />
ROP-2P32-LW-SC<br />
ROP-2P32-SC<br />
ROP-3P32-LW-SC<br />
ROP-3P32-SC<br />
VEL-2P32-LW-SC<br />
VEL-2P32-SC<br />
VEL-2P32-HL-SC<br />
VEL-3P32-LW-SC<br />
VEL-3P32-SC<br />
VEL-3P32-HL-SC<br />
VCN-2S32-SC<br />
VOP-2P32-LW-SC<br />
VOP-2P32-SC<br />
VOP-3P32-LW-SC<br />
VOP-3P32-SC<br />
ICN-2M32-MC<br />
ICN-2P32-LW-SC<br />
ICN-2P32-SC<br />
ICN-3P32-LW-SC<br />
ICN-3P32-SC<br />
IOP-2P32-LW-SC<br />
IOP-2P32-SC<br />
IOP-2P32-HL-SC<br />
IOP-3P32-LW-SC<br />
IOP-3P32-SC<br />
IOP-3P32-HL-90C-SC<br />
IOP-2S32-LW-SC<br />
IOP-2S32-SC<br />
IIC-2S32-SC<br />
GEL-2P32-LW-RH-TP<br />
GEL-2P32-SC<br />
GCN-2P32<br />
GCN-2S32<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
43 0.89 130<br />
41 0.78 25<br />
46 0.90 25<br />
61 1.24 20<br />
46 0.88 20<br />
54 1.06 20<br />
66 1.33 20<br />
53 0.95 10<br />
38 0.79 10<br />
43 0.88 10<br />
49 0.96 10<br />
59 0.96 10<br />
41 0.78 25<br />
46 0.90 25<br />
61 1.24 20<br />
46 0.88 20<br />
54 1.06 20<br />
66 1.33 20<br />
53 0.95 10<br />
38 0.79 10<br />
43 0.88 10<br />
43 0.86 15<br />
49 0.96 10<br />
44 0.88 15<br />
40 0.77 15<br />
48 0.91 10<br />
44 0.85 15<br />
51 1.03 15<br />
39 0.78 10<br />
43 0.88 10<br />
57 1.20 10<br />
43 0.86 10<br />
49 1.00 10<br />
64 1.32 10-15<br />
36 0.71 10<br />
43 0.89 10<br />
47 0.88 10<br />
41 0.78 25<br />
48 0.98 25<br />
47 0.92 15<br />
57 1.00 20<br />
Line<br />
Current<br />
(Amps)<br />
0.61<br />
0.35<br />
0.40<br />
0.51<br />
0.39<br />
0.42<br />
0.56<br />
0.45<br />
0.32<br />
0.37<br />
0.42<br />
0.50<br />
0.15<br />
0.17<br />
0.21<br />
0.17<br />
0.14<br />
0.24<br />
0.20<br />
0.14<br />
0.16<br />
0.16<br />
0.18<br />
0.37-0.16<br />
0.34-0.14<br />
0.40-0.18<br />
0.37-0.16<br />
0.43-0.19<br />
0.32-0.14<br />
0.37-0.16<br />
0.48-0.21<br />
0.36-0.16<br />
0.42-0.18<br />
0.54-0.24<br />
0.30-0.13<br />
0.36-0.16<br />
0.39-0.17<br />
0.12<br />
0.14<br />
0.14<br />
0.16<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
0/-18<br />
0/-18<br />
Dim.<br />
B<br />
B<br />
A2<br />
B<br />
A<br />
B<br />
A<br />
Wiring<br />
Dia.<br />
64<br />
*65<br />
21<br />
64<br />
*65<br />
64<br />
*65<br />
21<br />
64<br />
*65<br />
64<br />
*65<br />
64<br />
*65<br />
21<br />
64<br />
21<br />
ELECTRONIC<br />
FLUORESCENT<br />
‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />
See page 1-48 for Dimensions<br />
See page 1-51 for Wiring Diagrams<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-49
T8<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 25W - 36" Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
3<br />
Input<br />
Volts<br />
F25T8, FBO24T8 (25W - 36")<br />
AmbiStar ‡<br />
120<br />
277<br />
120-277<br />
347<br />
Lamp<br />
Starting<br />
Method<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
RS<br />
Ballast<br />
Family<br />
Standard<br />
Centium<br />
Optanium<br />
Standard<br />
Centium<br />
Optanium<br />
Centium<br />
Optanium<br />
Mark 5<br />
Standard<br />
Centium<br />
Catalog Number<br />
REB-4P32-SC<br />
REL-3P32-LW-SC<br />
REL-3P32-SC<br />
REL-3P32-HL-SC<br />
REL-4P32-LW-SC<br />
REL-4P32-SC<br />
RCN-3S32-SC<br />
ROP-3P32-LW-SC<br />
ROP-3P32-SC<br />
ROP-4P32-LW-SC<br />
ROP-4P32-SC<br />
ROP-4P32-HL-90C<br />
VEL-3P32-LW-SC<br />
VEL-3P32-SC<br />
VEL-3P32-HL-SC<br />
VEL-4P32-LW-SC<br />
VEL-4P32-SC<br />
VCN-3S32-SC<br />
VOP-3P32-LW-SC<br />
VOP-3P32-SC<br />
VOP-4P32-LW-SC<br />
VOP-4P32-SC<br />
VOP-4P32-HL-90C<br />
ICN-3P32-LW-SC<br />
ICN-3P32-SC<br />
ICN-4P32-LW-SC<br />
ICN-4P32-SC<br />
IOP-3P32-LW-SC<br />
IOP-3P32-SC<br />
IOP-3P32-HL-90C-SC<br />
IOP-4P32-LW-SC<br />
IOP-4P32-SC<br />
IOP-4P32-HL-90C-G<br />
IOP-3S32-LW-SC<br />
IOP-3S32-SC<br />
IIC-3S32-SC<br />
GEL-3P32-RH-TP<br />
GEL-4P32-LW<br />
GCN-3S32<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
63 0.86 125<br />
59 0.77 20<br />
66 0.93 20<br />
88 1.20 20<br />
62 0.83 20<br />
74 1.04 20<br />
77 0.95 10<br />
65 0.89 10<br />
77 0.88 10<br />
61 0.83 10<br />
70 0.92 10<br />
95 1.25 10<br />
46 0.88 20<br />
66 0.93 15<br />
88 1.20 20<br />
62 0.83 20<br />
74 1.04 20<br />
77 0.95 10<br />
57 0.79 10<br />
65 0.89 10<br />
61 0.83 10<br />
70 0.92 10<br />
95 1.25 10<br />
58 0.79 15<br />
67 0.90 10<br />
62 0.85 10<br />
74 1.01 10<br />
57 0.79 10<br />
64 0.88 10<br />
84 1.20 10<br />
62 0.85 10<br />
71 0.97 10<br />
94 1.28 10<br />
54 0.71 10<br />
64 0.88 10<br />
70 0.88 10<br />
70 0.95 25<br />
62 0.83 30<br />
82 1.02 20<br />
Line<br />
Current<br />
(Amps)<br />
1.14<br />
0.50<br />
0.55<br />
0.74<br />
0.53<br />
0.62<br />
0.65<br />
0.54<br />
0.65<br />
0.52<br />
0.58<br />
0.80<br />
0.17<br />
0.24<br />
0.32<br />
0.22<br />
0.27<br />
0.28<br />
0.21<br />
0.24<br />
0.23<br />
0.26<br />
0.35<br />
0.49-0.21<br />
0.56-0.24<br />
0.52-0.22<br />
0.62-0.27<br />
0.48-0.21<br />
0.54-0.24<br />
0.70-0.31<br />
0.52-0.22<br />
0.59-0.26<br />
0.80-0.35<br />
0.45-0.20<br />
0.53-0.23<br />
0.58-0.25<br />
0.21<br />
0.20<br />
0.25<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
0/-18<br />
32/0<br />
Dim.<br />
B<br />
A<br />
B<br />
A<br />
B<br />
G<br />
B<br />
A<br />
Wiring<br />
Dia.<br />
*66<br />
65<br />
*66<br />
30<br />
65<br />
*66<br />
65<br />
*66<br />
30<br />
65<br />
*66<br />
65<br />
*66<br />
65<br />
*66<br />
30<br />
65<br />
*66<br />
30<br />
‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />
See page 1-48 for Dimensions<br />
See page 1-51 for Wiring Diagrams<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-50<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 25W - 36" Lamps<br />
T8<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
F25T8, FBO24T8 (25W - 36")<br />
AmbiStar ‡<br />
4<br />
Input<br />
Volts<br />
120<br />
277<br />
120-277<br />
347<br />
Lamp<br />
Starting<br />
Method<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
Ballast<br />
Family<br />
Standard<br />
Centium<br />
Optanium<br />
Standard<br />
Centium<br />
Optanium<br />
Centium<br />
Optanium<br />
Standard<br />
Catalog Number<br />
REB-4P32-SC<br />
REL-4P32-LW-SC<br />
REL-4P32-SC<br />
RCN-4S32-SC<br />
ROP-4P32-LW-SC<br />
ROP-4P32-SC<br />
ROP-4P32-HL-90C<br />
VEL-4P32-LW-SC<br />
VEL-4P32-SC<br />
VCN-4S32-SC<br />
VOP-4P32-LW-SC<br />
VOP-4P32-SC<br />
VOP-4P32-HL-90C<br />
ICN-4P32-LW-SC<br />
ICN-4P32-SC<br />
IOP-4P32-LW-SC<br />
IOP-4P32-SC<br />
IOP-4P32-HL-90C-G<br />
IOP-4S32-LW-SC<br />
IOP-4S32-SC<br />
GEL-4P32-LW<br />
GEL-4P32-RH-TP<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
77 0.81 125<br />
76 0.76 20<br />
89 0.94 20<br />
101 0.95 10<br />
75 0.79 10<br />
85 0.88 10<br />
115 1.17 10<br />
76 0.76 20<br />
89 0.94 15<br />
101 0.95 10<br />
75 0.79 10<br />
85 0.88 10<br />
113 1.17 10<br />
75 0.79 10<br />
89 0.91 10<br />
76 0.79 10<br />
85 0.88 10<br />
113 1.20 10<br />
69 0.72 10<br />
85 0.88 10<br />
76 0.79 25<br />
85 0.88 25<br />
Line<br />
Current<br />
(Amps)<br />
1.31<br />
0.64<br />
0.74<br />
0.84<br />
0.63<br />
0.71<br />
0.97<br />
0.28<br />
0.32<br />
0.36<br />
0.28<br />
0.31<br />
0.41<br />
0.63-0.27<br />
0.74-0.32<br />
0.64-0.27<br />
0.72-0.31<br />
0.96-0.41<br />
0.58-0.25<br />
0.72-0.31<br />
0.23<br />
0.25<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
0/-18<br />
Dim.<br />
B<br />
A<br />
B<br />
A<br />
B<br />
G<br />
B<br />
A<br />
Wiring<br />
Dia.<br />
66<br />
138<br />
66<br />
66<br />
138<br />
66<br />
66<br />
138<br />
66<br />
ELECTRONIC<br />
FLUORESCENT<br />
‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />
LAMP<br />
LAMP<br />
LAMP<br />
LAMP<br />
LINE<br />
RED<br />
RED<br />
BLUE/WHITE<br />
BLUE/WHITE<br />
BLACK<br />
WHITE<br />
BALLAST<br />
Diag. 30<br />
YELLOW<br />
YELLOW<br />
BLUE<br />
BLUE<br />
LINE<br />
* YEL<br />
BLUE<br />
* YEL<br />
BLUE<br />
BALLAST<br />
WHITE<br />
RED<br />
BLACK<br />
RED<br />
*FOR SINGLE LAMP OPERATION, INSULATE<br />
YELLOW LEADS INDIVIDUALLY FOR 600V<br />
Diag. 39<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
BLUE<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
BLUE<br />
BLUE<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
BLUE<br />
BLUE<br />
BLUE<br />
LINE<br />
LAMP<br />
LINE<br />
LAMP<br />
LAMP<br />
LINE<br />
LAMP<br />
LAMP<br />
Diag. 63<br />
Diag. 64<br />
* For Single Lamp Operation, insulate unused<br />
blue lead for 600 volts<br />
LAMP<br />
Diag. 65<br />
* For Two Lamp Operation, insulate unused<br />
blue lead for 600 volts<br />
WHITE<br />
BLACK<br />
YELLOW<br />
YELLOW<br />
BALLAST<br />
BLUE<br />
BLUE<br />
RED<br />
RED<br />
LAMP<br />
LAMP<br />
LINE<br />
LAMP<br />
Diag. 66<br />
* For Three Lamp Operation, insulate unused<br />
blue lead for 600 volts<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
LAMP<br />
Diag. 138<br />
See page 1-48 for Dimensions<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-51
T8/ES<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 25W - 48" Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
1<br />
2<br />
3<br />
4<br />
Input<br />
Volts<br />
120-277<br />
120-277<br />
120-277<br />
120-277<br />
Lamp<br />
Starting<br />
Method<br />
F32T8/ES (25W - 48")<br />
IS<br />
PS<br />
IS<br />
PS<br />
IS<br />
PS<br />
IS<br />
PS<br />
Ballast<br />
Family<br />
Optanium<br />
Optanium<br />
Optanium<br />
Optanium<br />
Catalog Number<br />
IOP-1P32-LW-SC<br />
IOP-1P32-SC<br />
IOP-1P32-HL-SC<br />
IOP-2P32-LW-SC<br />
IOP-2P32-SC<br />
IOP-2P32-HL-SC<br />
IOP-1S32-LW-SC<br />
IOP-1S32-SC<br />
IOP-2S32-LW-SC<br />
IOP-2S32-SC<br />
IOP-2P32-LW-SC<br />
IOP-2P32-SC<br />
IOP-2P32-HL-SC<br />
IOP-3P32-LW-SC<br />
IOP-3P32-SC<br />
IOP-3P32-HL-90C-SC<br />
IOP-2S32-LW-SC<br />
IOP-2S32-SC<br />
IOP-3P32-LW-SC<br />
IOP-3P32-SC<br />
IOP-3P32-HL-90C-SC<br />
IOP-4P32-LW-SC<br />
IOP-4P32-SC<br />
IOP-4P32-HL-90C-G<br />
IOP-3S32-LW-SC<br />
IOP-3S32-SC<br />
IOP-4P32-LW-SC<br />
IOP-4P32-SC<br />
IOP-4P32-HL-90C-G<br />
IOP-4S32-LW-SC<br />
IOP-4S32-SC<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
21 0.77 10<br />
23 0.87 10<br />
32 1.21 10<br />
24 0.90 10<br />
27 1.05 10<br />
37 1.40 15<br />
21 0.72 10<br />
24 0.88 10<br />
21 0.73 10<br />
24 0.89 10-15<br />
38 0.77 10<br />
44-43 0.87 10<br />
60 1.19 10<br />
43 0.86 10<br />
49 1.00 10<br />
70 1.32 10-20<br />
39-38 0.71 10<br />
45-44 0.88 10<br />
58-57 0.77 10<br />
65-64 0.87 10<br />
95-93 1.20 10<br />
62-61 0.85 10<br />
70-69 0.97 10<br />
101-100 1.27 10<br />
57-56 0.71 10<br />
67-66 0.89 10<br />
77-75 0.77 10<br />
87-85 0.87 10<br />
124-122 1.19 10<br />
74-73 0.71 10<br />
87-85 0.87 10<br />
Line<br />
Current<br />
(Amps)<br />
0.17-0.07<br />
0.20-0.09<br />
0.26-0.12<br />
0.20-0.09<br />
0.23-0.10<br />
0.31-0.14<br />
0.17-0.07<br />
0.20-0.08<br />
0.17-0.08<br />
0.20-0.09<br />
0.32-0.14<br />
0.37-0.06<br />
0.50-0.22<br />
0.36-0.16<br />
0.42-0.18<br />
0.59-0.27<br />
0.32-0.14<br />
0.38-0.16<br />
0.49-0.21<br />
0.55-0.24<br />
0.79-0.35<br />
0.52-0.22<br />
0.59-0.26<br />
0.85-0.37<br />
0.48-0.21<br />
0.56-0.25<br />
0.65-0.28<br />
0.73-0.31<br />
1.05-0.45<br />
0.62-0.27<br />
0.73-0.31<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Note: energy-saving T8 lamps (25W, 28W or 30W) may experience lamp striations if operated on ballasts other than Optanium 2.0 (IOP) models.<br />
Remote or tandem wiring of energy-saving T8 lamps (25W, 28W or 30W) is only recommended for Optanium 2.0 (IOP) models.<br />
Max.<br />
THD<br />
%<br />
60/16<br />
60/16<br />
60/16<br />
60/16<br />
Dim.<br />
B<br />
B<br />
B<br />
G<br />
B<br />
B<br />
G<br />
B<br />
Wiring<br />
Dia.<br />
63<br />
*64<br />
20<br />
39<br />
64<br />
*65<br />
21<br />
65<br />
*66<br />
30<br />
66<br />
138<br />
See page 1-57 for Wiring Diagrams<br />
Fig. A<br />
1.18"<br />
1.7"<br />
8.90"<br />
9.5"<br />
Fig. B<br />
1.05"<br />
8.91"<br />
9.50"<br />
Fig. G<br />
1.08"<br />
Fig. A2<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-52<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 28W - 48" Lamps<br />
T8/ES<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
1<br />
2<br />
3<br />
4<br />
Input<br />
Volts<br />
120-277<br />
120-277<br />
120-277<br />
120-277<br />
Lamp<br />
Starting<br />
Method<br />
F32T8/ES (28W - 48")<br />
IS<br />
PS<br />
IS<br />
PS<br />
IS<br />
PS<br />
IS<br />
PS<br />
Ballast<br />
Family<br />
Optanium<br />
Optanium<br />
Optanium<br />
Optanium<br />
Catalog Number<br />
IOP-1P32-LW-SC<br />
IOP-1P32-SC<br />
IOP-1P32-HL-SC<br />
IOP-2P32-LW-SC<br />
IOP-2P32-SC<br />
IOP-2P32-HL-SC<br />
IOP-1S32-LW-SC<br />
IOP-1S32-SC<br />
IOP-2S32-LW-SC<br />
IOP-2S32-SC<br />
IOP-2P32-LW-SC<br />
IOP-2P32-SC<br />
IOP-2P32-HL-SC<br />
IOP-3P32-LW-SC<br />
IOP-3P32-SC<br />
IOP-3P32-HL-90C-SC<br />
IOP-2S32-LW-SC<br />
IOP-2S32-SC<br />
IOP-3P32-LW-SC<br />
IOP-3P32-SC<br />
IOP-3P32-HL-90C-SC<br />
IOP-4P32-LW-SC<br />
IOP-4P32-SC<br />
IOP-4P32-HL-90C-G<br />
IOP-3S32-LW-SC<br />
IOP-3S32-SC<br />
IOP-4P32-LW-SC<br />
IOP-4P32-SC<br />
IOP-4P32-HL-90C-G<br />
IOP-4S32-LW-SC<br />
IOP-4S32-SC<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
22 0.77 10<br />
25 0.87 10<br />
33 1.21 10<br />
26 0.90 10<br />
31 1.05 10<br />
39 1.38 10<br />
21 0.72 10<br />
25 0.88 10<br />
22 0.73 10<br />
26 0.88 10-15<br />
42 0.77 10<br />
48-47 0.87 10<br />
65-64 1.19 10<br />
47 0.86 10<br />
55-54 1.00 10<br />
74-73 1.31 10-15<br />
41-40 0.71 10<br />
49-48 0.88 10<br />
64-63 0.77 10<br />
72-71 0.87 10<br />
99-97 1.20 10<br />
69-68 0.85 10<br />
79-78 0.97 10<br />
107-106 1.24 10<br />
62-61 0.71 10<br />
72-71 0.89 10<br />
84-82 0.77 10<br />
96-94 0.87 10<br />
130-129 1.19 10<br />
80-79 0.71 10<br />
97-96 0.88 10<br />
Line<br />
Current<br />
(Amps)<br />
0.19-0.08<br />
0.22-0.10<br />
0.28-0.12<br />
0.22-0.10<br />
0.26-0.11<br />
0.33-0.15<br />
0.18-0.07<br />
0.20-0.09<br />
0.18-0.08<br />
0.21-0.09<br />
0.35-0.15<br />
0.41-0.18<br />
0.55-0.24<br />
0.40-0.18<br />
0.46-0.20<br />
0.62-0.27<br />
0.34-0.15<br />
0.41-0.18<br />
0.54-0.23<br />
0.61-0.26<br />
0.83-0.36<br />
0.58-0.25<br />
0.66-0.28<br />
0.90-0.39<br />
0.51-0.22<br />
0.60-0.26<br />
0.71-0.30<br />
0.81-0.35<br />
1.10-0.47<br />
0.67-0.29<br />
0.82-0.35<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
60/16<br />
60/16<br />
60/16<br />
60/16<br />
Dim.<br />
B<br />
B<br />
B<br />
G<br />
B<br />
B<br />
G<br />
B<br />
Wiring<br />
Dia.<br />
63<br />
*64<br />
20<br />
39<br />
64<br />
*65<br />
21<br />
65<br />
*66<br />
30<br />
66<br />
138<br />
ELECTRONIC<br />
FLUORESCENT<br />
Note: energy-saving T8 lamps (25W, 28W or 30W) may experience lamp striations if operated on ballasts other than Optanium 2.0 (IOP) models.<br />
Remote or tandem wiring of energy-saving T8 lamps (25W, 28W or 30W) is only recommended for Optanium 2.0 (IOP) models.<br />
See page 1-52 for Dimensions<br />
See page 1-57 for Wiring Diagrams<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-53
T8/ES<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 30W - 48" Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
1<br />
Input<br />
Volts<br />
120<br />
277<br />
120-277<br />
347<br />
Lamp<br />
Starting<br />
Method<br />
F32T8/ES (30W - 48")<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
RS<br />
Ballast<br />
Family<br />
Standard<br />
Centium<br />
Optanium<br />
Standard<br />
Centium<br />
Optanium<br />
Centium<br />
Optanium<br />
Mark 5<br />
Standard<br />
Centium<br />
Catalog Number<br />
REL-1P32-LW-SC<br />
REL-1P32-SC<br />
REL-1P32-HL-SC<br />
REL-2P32-LW-SC<br />
REL-2P32-SC<br />
REL-2P32-HL-SC<br />
RCN-1S32-SC<br />
ROP-2P32-LW-SC<br />
ROP-2P32-SC<br />
VEL-1P32-LW-SC<br />
VEL-1P32-SC<br />
VEL-1P32-HL-SC<br />
VEL-2P32-LW-SC<br />
VEL-2P32-SC<br />
VEL-2P32-HL-SC<br />
VCN-1S32-SC<br />
VOP-2P32-LW-SC<br />
VOP-2P32-SC<br />
ICN-132-MC<br />
ICN-1P32-LW-SC<br />
ICN-1P32-SC<br />
ICN-2P32-LW-SC<br />
ICN-2P32-SC<br />
IOP-1P32-LW-SC<br />
IOP-1P32-SC<br />
IOP-1P32-HL-SC<br />
IOP-2P32-LW-SC<br />
IOP-2P32-SC<br />
IOP-2P32-HL-SC<br />
IOP-1S32-LW-SC<br />
IOP-1S32-SC<br />
IOP-2S32-LW-SC<br />
IOP-2S32-SC<br />
IIC-132-SC<br />
GEL-2P32-SC<br />
GEL-2P32-LW-RH-TP<br />
GCN-2P32<br />
GCN-1S32<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
28 0.75 20<br />
29 0.92 20<br />
39 1.20 20<br />
30 0.93 30<br />
35 1.10 25<br />
45 1.41 20<br />
32 0.90 10<br />
28 0.87 10<br />
33 1.01 10<br />
27 0.75 20<br />
29 0.92 20<br />
39 1.20 20<br />
30 0.93 30<br />
35 1.10 25<br />
45 1.41 20<br />
32 0.90 10<br />
28 0.87 15<br />
33 1.01 15<br />
27 0.88 10<br />
25 0.77 10<br />
29 0.90 10<br />
29-28 0.85 15-20<br />
33 1.03 10<br />
24 0.77 10<br />
27 0.87 10<br />
37-36 1.20 10<br />
28 0.90 10<br />
33 1.05 10<br />
42 1.38 10<br />
23 0.72 10<br />
27 0.88 10<br />
24-23 0.73 10<br />
27 0.90 10<br />
30 0.88 10<br />
36 1.10 20<br />
33 0.98 20<br />
35 1.10 10<br />
32 0.90 10<br />
Line<br />
Current<br />
(Amps)<br />
0.23<br />
0.25<br />
0.33<br />
0.28<br />
0.31<br />
0.38<br />
0.27<br />
0.24<br />
0.28<br />
0.10<br />
0.11<br />
0.14<br />
0.12<br />
0.13<br />
0.17<br />
0.12<br />
0.10<br />
0.12<br />
0.23-0.10<br />
0.21-0.09<br />
0.24-0.11<br />
0.24-0.11<br />
0.28-0.12<br />
0.20-0.09<br />
0.23-0.10<br />
0.31-0.13<br />
0.24-0.10<br />
0.28-0.12<br />
0.35-0.16<br />
0.19-0.08<br />
0.22-0.10<br />
0.20-0.09<br />
0.23-0.10<br />
0.26-0.11<br />
0.10<br />
0.10<br />
0.11<br />
0.09<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
60/16<br />
60/16<br />
60/16<br />
60/16<br />
Dim.<br />
B<br />
B<br />
A2<br />
B<br />
B<br />
A<br />
Wiring<br />
Dia.<br />
63<br />
*64<br />
20<br />
*64<br />
63<br />
*64<br />
20<br />
*64<br />
63<br />
*64<br />
63<br />
*64<br />
20<br />
39<br />
20<br />
*64<br />
20<br />
Note: energy-saving T8 lamps (25W, 28W or 30W) may experience lamp striations if operated on ballasts other than Optanium 2.0 (IOP) models.<br />
Remote or tandem wiring of energy-saving T8 lamps (25W, 28W or 30W) is only recommended for Optanium 2.0 (IOP) models.<br />
See page 1-52 for Dimensions<br />
See page 1-57 for Wiring Diagrams<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-54<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 30W - 48" Lamps<br />
T8/ES<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
2<br />
Input<br />
Volts<br />
120<br />
277<br />
120-277<br />
347<br />
Lamp<br />
Starting<br />
Method<br />
F32T8/ES (30W - 48")<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
RS<br />
IS<br />
RS<br />
Ballast<br />
Family<br />
Standard<br />
Centium<br />
Optanium<br />
Standard<br />
Centium<br />
Optanium<br />
Centium<br />
Optanium<br />
Mark 5<br />
Standard<br />
Centium<br />
Catalog Number<br />
REL-2P32-LW-SC<br />
REL-2P32-SC<br />
REL-2P32-HL-SC<br />
REL-3P32-LW-SC<br />
REL-3P32-SC<br />
REL-3P32-HL-SC<br />
RCN-2S32-SC<br />
ROP-2P32-LW-SC<br />
ROP-2P32-SC<br />
ROP-3P32-LW-SC<br />
ROP-3P32-SC<br />
VEL-2P32-LW-SC<br />
VEL-2P32-SC<br />
VEL-2P32-HL-SC<br />
VEL-3P32-LW-SC<br />
VEL-3P32-SC<br />
VEL-3P32-HL-SC<br />
VCN-2S32-SC<br />
VOP-2P32-LW-SC<br />
VOP-2P32-SC<br />
VOP-3P32-LW-SC<br />
VOP-3P32-SC<br />
ICN-2M32-MC<br />
ICN-2P32-LW-SC<br />
ICN-2P32-SC<br />
ICN-3P32-LW-SC<br />
ICN-3P32-SC<br />
IOP-2P32-LW-SC<br />
IOP-2P32-SC<br />
IOP-2P32-HL-SC<br />
IOP-3P32-LW-SC<br />
IOP-3P32-SC<br />
IOP-3P32-HL-90C-SC<br />
IOP-2S32-LW-SC<br />
IOP-2S32-SC<br />
IIC-2S32-SC<br />
GEL-2P32-LW-RH-TP<br />
GEL-2P32-SC<br />
GEL-2S32-RH-TP<br />
GCN-2P32<br />
GCN-2S32<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
48 0.75 20<br />
54 0.87 20<br />
72 1.20 20<br />
54 0.87 20<br />
61 1.03 20<br />
80 1.32 20<br />
60 0.88 10<br />
45 0.78 10<br />
52 0.88 10<br />
51 0.85 10<br />
59 0.96 10<br />
48 0.75 20<br />
54 0.87 20<br />
72 1.20 20<br />
54 0.87 20<br />
61 1.03 20<br />
80 1.32 20<br />
60 0.88 10<br />
45 0.78 10<br />
52 0.88 10<br />
51 0.85 10<br />
58 0.96 10<br />
54 0.88 10<br />
47-46 0.77 10<br />
54 0.88 10<br />
52 0.83 10<br />
61 1.01 10<br />
45 0.77 10<br />
52-51 0.87 10<br />
72-70 1.19 10<br />
51 0.85 10<br />
59-58 1.00 10<br />
78-77 1.31 10<br />
44-43 0.71 10<br />
52 0.88 10<br />
57 0.88 10<br />
49 0.76 20<br />
56 0.88 20<br />
59 0.87 20<br />
55 0.90 10<br />
60 0.90 10<br />
Line<br />
Current<br />
(Amps)<br />
0.41<br />
0.46<br />
0.60<br />
0.45<br />
0.51<br />
0.67<br />
0.51<br />
0.38<br />
0.44<br />
0.43<br />
0.50<br />
0.18<br />
0.20<br />
0.26<br />
0.20<br />
0.22<br />
0.29<br />
0.22<br />
0.16<br />
0.19<br />
0.19<br />
0.21<br />
0.45-0.20<br />
0.39-0.17<br />
0.45-0.20<br />
0.44-0.19<br />
0.51-0.22<br />
0.38-0.17<br />
0.44-0.19<br />
0.60-0.26<br />
0.43-0.19<br />
0.50-0.21<br />
0.65-0.29<br />
0.36-0.16<br />
0.44-0.19<br />
0.49-0.21<br />
0.14<br />
0.17<br />
0.17<br />
0.16<br />
0.17<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
60/16<br />
60/16<br />
60/16<br />
60/16<br />
Dim.<br />
B<br />
B<br />
A2<br />
B<br />
A<br />
B<br />
A<br />
Wiring<br />
Dia.<br />
64<br />
*65<br />
21<br />
64<br />
*65<br />
64<br />
*65<br />
21<br />
64<br />
*65<br />
64<br />
*65<br />
64<br />
*65<br />
21<br />
64<br />
21<br />
64<br />
21<br />
ELECTRONIC<br />
FLUORESCENT<br />
Note: energy-saving T8 lamps (25W, 28W or 30W) may experience lamp striations if operated on ballasts other than Optanium 2.0 (IOP) models.<br />
Remote or tandem wiring of energy-saving T8 lamps (25W, 28W or 30W) is only recommended for Optanium 2.0 (IOP) models.<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
See page 1-52 for Dimensions<br />
See page 1-57 for Wiring Diagrams<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-55
T8/ES<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 30W - 48" Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
3<br />
Input<br />
Volts<br />
120<br />
277<br />
120-277<br />
347<br />
Lamp<br />
Starting<br />
Method<br />
F32T8/ES (30W - 48")<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
RS<br />
Ballast<br />
Family<br />
Standard<br />
Centium<br />
Optanium<br />
Standard<br />
Centium<br />
Optanium<br />
Centium<br />
Optanium<br />
Mark 5<br />
Standard<br />
Centium<br />
Catalog Number<br />
REL-3P32-LW-SC<br />
REL-3P32-SC<br />
REL-3P32-HL-SC<br />
REL-4P32-LW-SC<br />
REL-4P32-SC<br />
RCN-3S32-SC<br />
ROP-3P32-LW-SC<br />
ROP-3P32-SC<br />
ROP-4P32-LW-SC<br />
ROP-4P32-SC<br />
VEL-3P32-LW-SC<br />
VEL-3P32-SC<br />
VEL-3P32-HL-SC<br />
VEL-4P32-LW-SC<br />
VEL-4P32-SC<br />
VCN-3S32-SC<br />
VOP-3P32-LW-SC<br />
VOP-3P32-SC<br />
VOP-4P32-LW-SC<br />
VOP-4P32-SC<br />
VOP-4P32-HL-90C<br />
ICN-3P32-LW-SC<br />
ICN-3P32-SC<br />
ICN-4P32-LW-SC<br />
ICN-4P32-SC<br />
IOP-3P32-LW-SC<br />
IOP-3P32-SC<br />
IOP-3P32-HL-90C-SC<br />
IOP-4P32-LW-SC<br />
IOP-4P32-SC<br />
IOP-4P32-HL-90C-G<br />
IOP-3S32-LW-SC<br />
IOP-3S32-SC<br />
IIC-3S32-SC<br />
GEL-3P32-RH-TP<br />
GEL-4P32-LW<br />
GCN-3S32<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
70 0.75 20<br />
79 0.88 20<br />
105 1.18 20<br />
76 0.81 20<br />
87 1.00 20<br />
85 0.88 10<br />
51 0.85 10<br />
77 0.88 10<br />
73 0.83 10<br />
84 0.94 10<br />
70 0.75 20<br />
79 0.88 20<br />
105 1.18 20<br />
76 0.81 20<br />
87 1.00 20<br />
85 0.88 10<br />
66 0.78 10<br />
76 0.88 10<br />
73 0.83 10<br />
83 0.94 10<br />
110 1.25 10<br />
69-68 0.77 10<br />
79 0.88 10<br />
75-74 0.80 10<br />
87 1.00 10<br />
68-67 0.77 10<br />
77-76 0.87 10<br />
106-104 1.20 10<br />
75-74 0.84 10<br />
84-82 0.97 10<br />
115-114 1.24 10<br />
66-65 0.71 10<br />
77-76 0.88 10<br />
85 0.88 10<br />
90 0.97 20<br />
76 0.83 20<br />
89 0.89 10<br />
Line<br />
Current<br />
(Amps)<br />
0.58<br />
0.67<br />
0.88<br />
0.63<br />
0.73<br />
0.72<br />
0.43<br />
0.65<br />
0.61<br />
0.70<br />
0.25<br />
0.29<br />
0.38<br />
0.28<br />
0.32<br />
0.31<br />
0.24<br />
0.28<br />
0.27<br />
0.30<br />
0.40<br />
0.57-0.25<br />
0.66-0.29<br />
0.62-0.27<br />
0.73-0.32<br />
0.57-0.25<br />
0.65-0.28<br />
0.88-0.38<br />
0.63-0.27<br />
0.70-0.30<br />
0.97-0.42<br />
0.55-0.24<br />
0.64-0.28<br />
0.72-0.31<br />
0.26<br />
0.23<br />
0.26<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
60/16<br />
60/16<br />
60/16<br />
60/16<br />
Dim.<br />
B<br />
B<br />
B<br />
G<br />
B<br />
A<br />
Wiring<br />
Dia.<br />
65<br />
*66<br />
30<br />
65<br />
*66<br />
65<br />
*66<br />
30<br />
65<br />
*66<br />
65<br />
*66<br />
65<br />
*66<br />
30<br />
65<br />
*66<br />
30<br />
Note: energy-saving T8 lamps (25W, 28W or 30W) may experience lamp striations if operated on ballasts other than Optanium 2.0 (IOP) models.<br />
Remote or tandem wiring of energy-saving T8 lamps (25W, 28W or 30W) is only recommended for Optanium 2.0 (IOP) models.<br />
See page 1-52 for Dimensions<br />
See page 1-57 for Wiring Diagrams<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-56<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 30W - 48" Lamps<br />
T8/ES<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
F32T8/ES (30W - 48")<br />
4<br />
Input<br />
Volts<br />
120<br />
277<br />
120-277<br />
347<br />
Lamp<br />
Starting<br />
Method<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
Ballast<br />
Family<br />
Standard<br />
Centium<br />
Optanium<br />
Standard<br />
Centium<br />
Optanium<br />
Centium<br />
Optanium<br />
Standard<br />
Catalog Number<br />
REL-4P32-LW-SC<br />
REL-4P32-SC<br />
RCN-4S32-SC<br />
ROP-4P32-LW-SC<br />
ROP-4P32-SC<br />
ROP-4P32-HL-90C<br />
VEL-4P32-LW-SC<br />
VEL-4P32-SC<br />
VCN-4S32-SC<br />
VOP-4P32-LW-SC<br />
VOP-4P32-SC<br />
VOP-4P32-HL-90C<br />
ICN-4P32-LW-SC<br />
ICN-4P32-SC<br />
IOP-4P32-LW-SC<br />
IOP-4P32-SC<br />
IOP-4P32-HL-90C-G<br />
IOP-4S32-LW-SC<br />
IOP-4S32-SC<br />
GEL-4P32-LW<br />
GEL-4P32-RH-TP<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
91 0.75 20<br />
104 0.88 20<br />
114 0.88 10<br />
89 0.78 10<br />
102 0.88 10<br />
133 1.18 10<br />
91 0.75 20<br />
104 0.88 20<br />
114 0.88 10<br />
73 0.83 10<br />
101 0.88 10<br />
132 1.18 10<br />
91-89 0.77 10<br />
105 0.88 10<br />
90-88 0.77 10<br />
102-100 0.87 10<br />
143-140 1.18 10<br />
86-84 0.71 10<br />
102-100 0.88 10<br />
90 0.76 20<br />
102 0.88 20<br />
Line<br />
Current<br />
(Amps)<br />
0.76<br />
0.87<br />
0.97<br />
0.75<br />
0.86<br />
1.12<br />
0.33<br />
0.38<br />
0.42<br />
0.32<br />
0.37<br />
0.48<br />
0.76-0.32<br />
0.88-0.38<br />
0.76-0.33<br />
0.86-0.37<br />
1.21-0.51<br />
0.71-0.31<br />
0.86-0.37<br />
0.26<br />
0.30<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
60/16<br />
60/16<br />
60/16<br />
60/16<br />
Dim.<br />
B<br />
A<br />
B<br />
A<br />
B<br />
G<br />
B<br />
A<br />
Wiring<br />
Dia.<br />
66<br />
138<br />
66<br />
66<br />
138<br />
66<br />
66<br />
138<br />
66<br />
ELECTRONIC<br />
FLUORESCENT<br />
Note: energy-saving T8 lamps (25W, 28W or 30W) may experience lamp striations if operated on ballasts other than Optanium 2.0 (IOP) models.<br />
Remote or tandem wiring of energy-saving T8 lamps (25W, 28W or 30W) is only recommended for Optanium 2.0 (IOP) models.<br />
LAMP<br />
LAMP<br />
LAMP<br />
LINE<br />
RED<br />
RED<br />
BLUE/WHITE<br />
BLUE/WHITE<br />
BLACK<br />
WHITE<br />
LAMP<br />
BALLAST<br />
Diag. 30<br />
YELLOW<br />
YELLOW<br />
BLUE<br />
BLUE<br />
LINE<br />
* YEL<br />
BLUE<br />
* YEL<br />
BLUE<br />
BALLAST<br />
WHITE<br />
RED<br />
BLACK<br />
RED<br />
*FOR SINGLE LAMP OPERATION, INSULATE<br />
YELLOW LEADS INDIVIDUALLY FOR 600V<br />
Diag. 39<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
BLUE<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
BLUE<br />
BLUE<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
BLUE<br />
BLUE<br />
BLUE<br />
LINE<br />
LAMP<br />
LINE<br />
LAMP<br />
LAMP<br />
LINE<br />
LAMP<br />
LAMP<br />
Diag. 63<br />
Diag. 64<br />
* For Single Lamp Operation, insulate unused<br />
blue lead for 600 volts<br />
LAMP<br />
Diag. 65<br />
* For Two Lamp Operation, insulate unused<br />
blue lead for 600 volts<br />
WHITE<br />
BLACK<br />
YELLOW<br />
YELLOW<br />
BALLAST<br />
BLUE<br />
BLUE<br />
RED<br />
RED<br />
LAMP<br />
LAMP<br />
LINE<br />
LAMP<br />
LAMP<br />
Diag. 66<br />
* For Three Lamp Operation, insulate unused<br />
blue lead for 600 volts<br />
Diag. 138<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
See page 1-52 for Dimensions<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-57
T8<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 32W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
1<br />
Input<br />
Volts<br />
120<br />
277<br />
120-277<br />
347<br />
Lamp<br />
Starting<br />
Method<br />
IS<br />
PS<br />
RS<br />
IS<br />
IS<br />
PS<br />
RS<br />
IS<br />
IS<br />
PS<br />
IS<br />
RS<br />
Ballast<br />
Family<br />
F32T8, FBO31T8, F32T8/U6 (32W)<br />
AmbiStar ‡<br />
Standard<br />
Centium<br />
PowrKut<br />
Optanium<br />
Standard<br />
Centium<br />
PowrKut<br />
Optanium<br />
Centium<br />
Optanium<br />
Mark 5<br />
Standard<br />
Centium<br />
PowrKut<br />
Catalog Number<br />
REB-2P32-SC<br />
REL-1P32-LW-SC<br />
REL-1P32-SC<br />
REL-1P32-HL-SC<br />
REL-2P32-LW-SC<br />
REL-2P32-SC<br />
REL-2P32-HL-SC<br />
RCN-1S32-SC<br />
RK-132-TP<br />
ROP-2P32-LW-SC<br />
ROP-2P32-SC<br />
VEL-1P32-LW-SC<br />
VEL-1P32-SC<br />
VEL-1P32-HL-SC<br />
VEL-2P32-LW-SC<br />
VEL-2P32-SC<br />
VEL-2P32-HL-SC<br />
VCN-1S32-SC<br />
VK-132-TP<br />
VOP-2P32-LW-SC<br />
VOP-2P32-SC<br />
ICN-132-MC<br />
ICN-1P32-LW-SC<br />
ICN-1P32-SC<br />
ICN-2P32-LW-SC<br />
ICN-2P32-SC<br />
IOP-1P32-LW-SC<br />
IOP-1P32-SC<br />
IOP-1P32-HL-SC<br />
IOP-2P32-LW-SC<br />
IOP-2P32-SC<br />
IOP-2P32-HL-SC<br />
IOP-1S32-LW-SC<br />
IOP-1S32-SC<br />
IOP-2S32-LW-SC<br />
IOP-2S32-SC<br />
IIC-132-SC<br />
GEL-2P32-SC<br />
GCN-2P32<br />
GCN-1S32<br />
GK-132-TP<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
33 1.00 140<br />
29 0.75 20<br />
32 0.92 20<br />
41 1.20 20<br />
33 0.93 30<br />
38 1.10 25<br />
47 1.41 20<br />
34 0.90 10<br />
34 0.85 20<br />
30 0.87 10<br />
35 1.01 10<br />
29 0.75 20<br />
32 0.92 20<br />
41 1.20 20<br />
33 0.93 30<br />
38 1.10 25<br />
47 1.41 20<br />
34 0.90 10<br />
34 0.85 20<br />
30 0.87 15<br />
35 1.01 15<br />
30 0.88 10<br />
27 0.77 10<br />
31 0.90 10<br />
32 0.85 15-20<br />
36 1.03 15<br />
25 0.77 10<br />
28 0.87 10<br />
39-38 1.18 10<br />
31 0.90 10<br />
35 1.05 10<br />
45 1.37 10<br />
25 0.72 10<br />
28 0.88 10<br />
25 0.73 10<br />
29 0.90 10<br />
32 0.88 10<br />
38 1.10 25<br />
39 1.12 20<br />
34 0.87 10<br />
34 0.85 20<br />
Line<br />
Current<br />
(Amps)<br />
0.48<br />
0.24<br />
0.27<br />
0.35<br />
0.30<br />
0.34<br />
0.40<br />
0.29<br />
0.31<br />
0.25<br />
0.30<br />
0.11<br />
0.12<br />
0.15<br />
0.13<br />
0.15<br />
0.18<br />
0.13<br />
0.13<br />
0.11<br />
0.13<br />
0.25-0.11<br />
0.22-0.10<br />
0.26-0.12<br />
0.27-0.12<br />
0.30-0.14<br />
0.22-0.10<br />
0.25-0.11<br />
0.33-0.14<br />
0.26-0.11<br />
0.30-0.13<br />
0.37-0.17<br />
0.20-0.09<br />
0.24-0.10<br />
0.20-0.09<br />
0.24-0.11<br />
0.28-0.12<br />
0.12<br />
0.12<br />
0.10<br />
0.11<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
0/-18<br />
32/0<br />
50/10<br />
0/-18<br />
0/-18<br />
32/0<br />
50/10<br />
0/-18<br />
0/-18<br />
0/-18<br />
32/0<br />
50/10<br />
Dim.<br />
B<br />
A<br />
B<br />
B<br />
A<br />
B<br />
A2<br />
B<br />
B<br />
A<br />
Wiring<br />
Dia.<br />
*64<br />
63<br />
*64<br />
20<br />
*64<br />
63<br />
*64<br />
20<br />
*64<br />
63<br />
*64<br />
63<br />
*64<br />
20<br />
39<br />
20<br />
*64<br />
20<br />
‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />
See page 1-52 for Dimensions<br />
See page 1-61 for Wiring Diagrams<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-58<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 32W Lamps<br />
T8<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
2<br />
Input<br />
Volts<br />
120<br />
220<br />
277<br />
120-277<br />
347<br />
Lamp<br />
Starting<br />
Method<br />
IS<br />
PS<br />
RS<br />
IS<br />
RS<br />
IS<br />
PS<br />
RS<br />
IS<br />
IS<br />
PS<br />
IS<br />
RS<br />
IS<br />
RS<br />
Ballast<br />
Family<br />
F32T8, FBO31T8, F32T8/U6 (32W)<br />
AmbiStar ‡<br />
Standard<br />
Centium<br />
PowrKut<br />
Optanium<br />
PowrKut<br />
Standard<br />
Centium<br />
PowrKut<br />
Optanium<br />
Centium<br />
Optanium<br />
Mark 5<br />
Standard<br />
Centium<br />
PowrKut<br />
Catalog Number<br />
REB-2P32-SC<br />
REL-2P32-LW-SC<br />
REL-2P32-SC<br />
REL-2P32-HL-SC<br />
REL-3P32-LW-SC<br />
REL-3P32-SC<br />
REL-3P32-HL-SC<br />
RCN-2S32-SC<br />
RK-2S32-TP<br />
ROP-2P32-LW-SC<br />
ROP-2P32-SC<br />
ROP-3P32-LW-SC<br />
ROP-3P32-SC<br />
YK-2S32-TP<br />
VEL-2P32-LW-SC<br />
VEL-2P32-SC<br />
VEL-2P32-HL-SC<br />
VEL-3P32-LW-SC<br />
VEL-3P32-SC<br />
VEL-3P32-HL-SC<br />
VCN-2S32-SC<br />
VK-2S32-TP<br />
VOP-2P32-LW-SC<br />
VOP-2P32-SC<br />
VOP-3P32-LW-SC<br />
VOP-3P32-SC<br />
ICN-2M32-MC<br />
ICN-2P32-LW-SC<br />
ICN-2P32-SC<br />
ICN-3P32-LW-SC<br />
ICN-3P32-SC<br />
IOP-2P32-LW-SC<br />
IOP-2P32-SC<br />
IOP-2P32-HL-SC<br />
IOP-3P32-LW-SC<br />
IOP-3P32-SC<br />
IOP-3P32-HL-90C-SC<br />
IOP-2S32-LW-SC<br />
IOP-2S32-SC<br />
IIC-2S32-SC<br />
GEL-2P32-LW-RH-TP<br />
GEL-2P32-SC<br />
GEL-2S32-RH-TP<br />
GCN-2P32<br />
GCN-2S32<br />
GK-2S32-TP<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
56 0.88 120<br />
51 0.75 20<br />
58 0.87 20<br />
77 1.20 20<br />
59 0.87 20<br />
65 1.03 20<br />
85 1.32 20<br />
63 0.88 10<br />
62 0.87 15<br />
48 0.78 10<br />
55 0.88 10<br />
54 0.85 10<br />
63 0.94 10<br />
63 0.87 15<br />
51 0.75 20<br />
58 0.87 20<br />
77 1.20 20<br />
59 0.87 20<br />
65 1.03 20<br />
85 1.32 20<br />
63 0.88 10<br />
62 0.87 15<br />
48 0.78 10<br />
55 0.88 10<br />
54 0.85 10<br />
62 0.94 10<br />
59 0.88 10<br />
50-49 0.77 10<br />
59 0.88 10<br />
57-56 0.86 10<br />
65 1.01 10<br />
48 0.77 10<br />
55-54 0.87 10<br />
74-72 1.18 10<br />
55-54 0.85 10<br />
63-62 1.00 10<br />
80-79 1.38 10<br />
47-46 0.71 10<br />
56-55 0.88 10<br />
61 0.88 10<br />
52 0.75 20<br />
59 0.87 20<br />
62 0.89 20<br />
59 0.90 10<br />
63 0.90 10<br />
63 0.89 15<br />
‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />
Max.<br />
THD<br />
%<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
Line<br />
Current<br />
(Amps)<br />
0.80<br />
0.44<br />
0.49<br />
0.65<br />
0.49<br />
0.54<br />
0.71<br />
0.53<br />
0.56<br />
0.41<br />
0.47<br />
0.45<br />
0.53<br />
0.29<br />
0.19<br />
0.21<br />
0.28<br />
0.21<br />
0.24<br />
0.31<br />
0.23<br />
0.24<br />
0.17<br />
0.20<br />
0.20<br />
0.24<br />
0.50-0.21<br />
0.42-0.12<br />
0.49-0.22<br />
0.48-0.21<br />
0.54-0.24<br />
0.41-0.17<br />
0.47-0.20<br />
0.62-0.26<br />
0.46-0.20<br />
0.53-0.23<br />
0.67-0.29<br />
0.38-0.17<br />
0.47-0.20<br />
0.51-0.22<br />
0.15<br />
0.17<br />
0.18<br />
0.17<br />
0.18<br />
0.20<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
0/-18<br />
32/0<br />
50/10<br />
0/-18<br />
50/10<br />
0/-18<br />
32/0<br />
50/10<br />
0/-18<br />
0/-18<br />
0/-18<br />
32/0<br />
0/-18<br />
32/0<br />
50/10<br />
Dim.<br />
B<br />
A<br />
B<br />
A<br />
B<br />
A<br />
B<br />
A2<br />
B<br />
A<br />
B<br />
A<br />
Wiring<br />
Dia.<br />
64<br />
*65<br />
21<br />
64<br />
*65<br />
21<br />
64<br />
*65<br />
21<br />
64<br />
*65<br />
64<br />
*65<br />
64<br />
*65<br />
21<br />
64<br />
21<br />
64<br />
21<br />
See page 1-52 for Dimensions<br />
See page 1-61 for Wiring Diagrams<br />
ELECTRONIC<br />
FLUORESCENT<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-59
T8<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 32W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
3<br />
Input<br />
Volts<br />
120<br />
277<br />
120-277<br />
347<br />
Lamp<br />
Starting<br />
Method<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
RS<br />
Ballast<br />
Family<br />
F32T8, FBO31T8, F32T8/U6 (32W)<br />
AmbiStar ‡<br />
Standard<br />
Centium<br />
Optanium<br />
Standard<br />
Centium<br />
Optanium<br />
Centium<br />
Optanium<br />
Mark 5<br />
Standard<br />
Centium<br />
Catalog Number<br />
REB-4P32-SC<br />
REL-3P32-LW-SC<br />
REL-3P32-SC<br />
REL-3P32-HL-SC<br />
REL-4P32-LW-SC<br />
REL-4P32-SC<br />
RCN-3S32-SC<br />
ROP-3P32-LW-SC<br />
ROP-3P32-SC<br />
ROP-4P32-LW-SC<br />
ROP-4P32-SC<br />
ROP-4P32-HL-90C<br />
VEL-3P32-LW-SC<br />
VEL-3P32-SC<br />
VEL-3P32-HL-SC<br />
VEL-4P32-LW-SC<br />
VEL-4P32-SC<br />
VCN-3S32-SC<br />
VOP-3P32-LW-SC<br />
VOP-3P32-SC<br />
VOP-4P32-LW-SC<br />
VOP-4P32-SC<br />
VOP-4P32-HL-90C<br />
ICN-3P32-LW-SC<br />
ICN-3P32-SC<br />
ICN-4P32-LW-SC<br />
ICN-4P32-SC<br />
IOP-3P32-LW-SC<br />
IOP-3P32-SC<br />
IOP-3P32-HL-90C-SC<br />
IOP-4P32-LW-SC<br />
IOP-4P32-SC<br />
IOP-4P32-HL-90C-G<br />
IOP-3S32-LW-SC<br />
IOP-3S32-SC<br />
IIC-3S32-SC<br />
GEL-3P32-RH-TP<br />
GEL-4P32-LW<br />
GCN-3S32<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
80 0.84 125<br />
76 0.75 20<br />
85 0.88 20<br />
111 1.19 20<br />
82 0.81 20<br />
94 1.00 20<br />
91 0.88 10<br />
73 0.78 10<br />
83 0.88 10<br />
78 0.82 10<br />
89 0.92 10<br />
119 1.20 10<br />
76 0.75 20<br />
85 0.88 20<br />
111 1.19 20<br />
82 0.81 20<br />
94 1.00 20<br />
91 0.88 10<br />
73 0.78 10<br />
82 0.88 10<br />
78 0.82 10<br />
89 0.92 10<br />
117 1.25 10<br />
74-73 0.77 10<br />
85 0.88 10<br />
80-79 0.82 10<br />
93 1.00 10<br />
73-71 0.77 10<br />
82-80 0.87 10<br />
110-707 1.18 10<br />
80-79 0.84 10<br />
90-88 0.97 10<br />
120-119 1.26 10<br />
71-70 0.71 10<br />
83-81 0.88 10<br />
91 0.88 10<br />
90 0.97 20<br />
82 0.81 25<br />
94 0.92 10<br />
Line<br />
Current<br />
(Amps)<br />
1.36<br />
0.64<br />
0.71<br />
0.93<br />
0.69<br />
0.79<br />
0.78<br />
0.61<br />
0.70<br />
0.65<br />
0.75<br />
0.99<br />
0.27<br />
0.31<br />
0.40<br />
0.29<br />
0.34<br />
0.34<br />
0.27<br />
0.30<br />
0.29<br />
0.33<br />
0.43<br />
0.62-0.27<br />
0.88-0.88<br />
0.67-0.29<br />
0.78-0.33<br />
0.62-0.27<br />
0.70-0.30<br />
0.91-0.39<br />
0.67-0.29<br />
0.75-0.32<br />
1.02-0.44<br />
0.59-0.21<br />
0.70-0.30<br />
0.76-0.32<br />
0.26<br />
0.24<br />
0.28<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
0/-18<br />
32/0<br />
Dim.<br />
B<br />
B<br />
B<br />
G<br />
B<br />
A<br />
Wiring<br />
Dia.<br />
*66<br />
65<br />
*66<br />
30<br />
65<br />
*66<br />
65<br />
*66<br />
30<br />
65<br />
*66<br />
65<br />
*66<br />
65<br />
*66<br />
30<br />
65<br />
*66<br />
30<br />
‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />
See page 1-52 for Dimensions<br />
See page 1-61 for Wiring Diagrams<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-60<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 32W Lamps<br />
T8<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
F32T8, FBO31T8, F32T8/U6 (32W)<br />
AmbiStar ‡<br />
IS<br />
Standard<br />
120 PS Centium<br />
4<br />
Input<br />
Volts<br />
277<br />
120-277<br />
347<br />
Lamp<br />
Starting<br />
Method<br />
IS<br />
IS<br />
PS<br />
IS<br />
IS<br />
PS<br />
IS<br />
Ballast<br />
Family<br />
Optanium<br />
Standard<br />
Centium<br />
Optanium<br />
Centium<br />
Optanium<br />
Standard<br />
Catalog Number<br />
REB-4P32-SC<br />
REL-4P32-LW-SC<br />
REL-4P32-SC<br />
RCN-4S32-SC<br />
ROP-4P32-LW-SC<br />
ROP-4P32-SC<br />
ROP-4P32-HL-90C<br />
VEL-4P32-LW-SC<br />
VEL-4P32-SC<br />
VCN-4S32-SC<br />
VOP-4P32-LW-SC<br />
VOP-4P32-SC<br />
VOP-4P32-HL-90C<br />
ICN-4P32-LW-SC<br />
ICN-4P32-SC<br />
IOP-4P32-LW-SC<br />
IOP-4P32-SC<br />
IOP-4P32-HL-90C-G<br />
IOP-4S32-LW-SC<br />
IOP-4S32-SC<br />
GEL-4P32-LW<br />
GEL-4P32-RH-TP<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
103 0.81 125<br />
98 0.75 20<br />
112 0.88 20<br />
121 0.88 10<br />
96 0.78 10<br />
108 0.88 10<br />
146 1.18 10<br />
98 0.75 20<br />
112 0.88 20<br />
121 0.88 10<br />
95 0.78 10<br />
107 0.88 10<br />
143 1.18 10<br />
97-95 0.77 10<br />
112 0.88 10<br />
96-94 0.77 10<br />
109-106 0.87 10<br />
146-143 1.18 10<br />
93-91 0.71 10<br />
110 0.88 10<br />
98 0.75 20<br />
112 0.85 20<br />
Line<br />
Current<br />
(Amps)<br />
1.57<br />
0.82<br />
0.94<br />
1.03<br />
0.81<br />
0.91<br />
1.22<br />
0.36<br />
0.41<br />
0.45<br />
0.35<br />
0.39<br />
0.52<br />
0.81-0.34<br />
0.94-0.41<br />
0.81-0.35<br />
0.92-0.39<br />
1.23-0.53<br />
0.77-0.33<br />
0.92-0.40<br />
0.29<br />
0.31<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
32/0<br />
0/-18<br />
0/-18<br />
0/-18<br />
Dim.<br />
B<br />
A<br />
B<br />
A<br />
B<br />
G<br />
B<br />
A<br />
Wiring<br />
Dia.<br />
66<br />
138<br />
66<br />
66<br />
138<br />
66<br />
66<br />
138<br />
66<br />
ELECTRONIC<br />
FLUORESCENT<br />
‡ The above AmbiStar ballasts are normal power factor and labeled ‘For Residential Use Only’<br />
LAMP<br />
LAMP<br />
LAMP<br />
LAMP<br />
LINE<br />
RED<br />
RED<br />
BLUE/WHITE<br />
BLUE/WHITE<br />
BLACK<br />
WHITE<br />
BALLAST<br />
Diag. 30<br />
YELLOW<br />
YELLOW<br />
BLUE<br />
BLUE<br />
LINE<br />
* YEL<br />
BLUE<br />
* YEL<br />
BLUE<br />
BALLAST<br />
WHITE<br />
RED<br />
BLACK<br />
RED<br />
*FOR SINGLE LAMP OPERATION, INSULATE<br />
YELLOW LEADS INDIVIDUALLY FOR 600V<br />
Diag. 39<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
BLUE<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
BLUE<br />
BLUE<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
BLUE<br />
BLUE<br />
BLUE<br />
LINE<br />
LAMP<br />
LINE<br />
LAMP<br />
LAMP<br />
LINE<br />
LAMP<br />
LAMP<br />
Diag. 63<br />
Diag. 64<br />
* For Single Lamp Operation, insulate unused<br />
blue lead for 600 volts<br />
LAMP<br />
Diag. 65<br />
* For Two Lamp Operation, insulate unused<br />
blue lead for 600 volts<br />
WHITE<br />
BLACK<br />
YELLOW<br />
YELLOW<br />
BALLAST<br />
BLUE<br />
BLUE<br />
RED<br />
RED<br />
LAMP<br />
LAMP<br />
LINE<br />
LAMP<br />
LAMP<br />
Diag. 66<br />
* For Three Lamp Operation, insulate unused<br />
blue lead for 600 volts<br />
Diag. 138<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
See page 1-52 for Dimensions<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-61
T8<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 40W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
1<br />
2<br />
Input<br />
Volts<br />
F40T8 (40W)<br />
120<br />
277<br />
120-277<br />
120<br />
277<br />
120-277<br />
Lamp<br />
Starting<br />
Method<br />
IS<br />
IS<br />
IS<br />
PS<br />
IS<br />
IS<br />
IS<br />
Ballast<br />
Family<br />
Standard<br />
Optanium<br />
Standard<br />
Optanium<br />
Centium<br />
Optanium<br />
Standard<br />
Optanium<br />
Standard<br />
Optanium<br />
Centium<br />
Optanium<br />
Catalog Number<br />
REL-1P32-HL-SC<br />
REL-2P32-LW-SC<br />
REL-2P32-HL-SC<br />
ROP-2P32-LW-SC<br />
ROP-2P32-SC<br />
VEL-1P32-HL-SC<br />
VEL-2P32-LW-SC<br />
VEL-2P32-HL-SC<br />
VOP-2P32-LW-SC<br />
VOP-2P32-SC<br />
ICN-2P32-LW-SC<br />
ICN-2P32-SC<br />
IOP-2P32-LW-SC<br />
IOP-2P32-SC<br />
IOP-2P32-HL-SC<br />
IOP-2S32-LW-SC<br />
IOP-2S32-SC<br />
REL-3P32-LW-SC<br />
REL-3P32-SC<br />
REL-3P32-HL-SC<br />
ROP-2P32-LW-SC<br />
ROP-2P32-SC<br />
ROP-3P32-LW-SC<br />
ROP-3P32-SC<br />
VEL-3P32-LW-SC<br />
VEL-3P32-SC<br />
VEL-3P32-HL-SC<br />
VOP-2P32-LW-SC<br />
VOP-2P32-SC<br />
VOP-3P32-LW-SC<br />
VOP-3P32-SC<br />
ICN-3P32-LW-SC<br />
ICN-3P32-SC<br />
IOP-3P32-LW-SC<br />
IOP-3P32-SC<br />
IOP-3P32-HL-90C-SC<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
49 1.06 20<br />
39 0.88 25<br />
58 1.38 20<br />
35 0.87 10<br />
41 1.01 10<br />
49 1.16 20<br />
39 0.88 25<br />
58 1.38 20<br />
35 0.87 15<br />
41 1.01 15<br />
37 0.86 10-15<br />
42 1.00 10<br />
35 0.87 10<br />
41 1.01 10<br />
55-54 1.35 10<br />
31-30 0.73 10<br />
36 0.90 10<br />
70 0.86 20<br />
79 1.01 20<br />
103 1.30 20<br />
58 0.78 10<br />
067 0.88 10<br />
66 0.83 10<br />
75 0.95 10<br />
70 0.86 20<br />
79 1.01 15<br />
103 1.30 20<br />
58 0.78 10<br />
67 0.88 10<br />
66 0.83 10<br />
74 0.95 10<br />
69-67 0.83 10<br />
77 1.00 10<br />
67-66 0.85 10<br />
74-72 1.01 10<br />
102-100 1.30 10<br />
Line<br />
Current<br />
(Amps)<br />
0.41<br />
0.34<br />
0.49<br />
0.30<br />
0.35<br />
0.18<br />
0.15<br />
0.21<br />
0.13<br />
0.15<br />
0.31-0.14<br />
0.35-0.15<br />
0.29-0.13<br />
0.35-0.15<br />
0.46-0.20<br />
0.73-0.11<br />
0.30-0.13<br />
0.59<br />
0.66<br />
0.86<br />
0.49<br />
0.56<br />
0.56<br />
0.64<br />
0.26<br />
0.31<br />
0.37<br />
0.22<br />
0.24<br />
0.24<br />
0.27<br />
0.58-0.25<br />
0.65-0.28<br />
0.58-0.25<br />
0.64-0.27<br />
0.85-0.37<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
0/-18<br />
0/-18<br />
0/-18<br />
0/-18<br />
0/-18<br />
0/-18<br />
Dim.<br />
B<br />
B<br />
B<br />
B<br />
B<br />
B<br />
Wiring<br />
Dia.<br />
63<br />
*64<br />
63<br />
*64<br />
*64<br />
39<br />
*65<br />
64<br />
*65<br />
*65<br />
64<br />
*65<br />
*65<br />
See page 1-63 for Dimensions and Wiring Diagrams<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-62<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 40W Lamps<br />
T8<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
F40T8 (40W)<br />
3<br />
4<br />
Input<br />
Volts<br />
120<br />
277<br />
120-277<br />
347<br />
120<br />
277<br />
Lamp<br />
Starting<br />
Method<br />
IS<br />
IS<br />
IS<br />
IS<br />
IS<br />
Ballast<br />
Family<br />
Standard<br />
Optanium<br />
Standard<br />
Optanium<br />
Centium<br />
Optanium<br />
Standard<br />
Optanium<br />
Catalog Number<br />
REL-4P32-LW-SC<br />
REL-4P32-SC<br />
ROP-3P32-LW-SC<br />
ROP-3P32-SC<br />
ROP-4P32-LW-SC<br />
ROP-4P32-SC<br />
ROP-4P32-HL-90C<br />
VEL-4P32-LW-SC<br />
VEL-4P32-SC<br />
VOP-3P32-LW-SC<br />
VOP-3P32-SC<br />
VOP-4P32-LW-SC<br />
VOP-4P32-SC<br />
VOP-4P32-HL-90C<br />
ICN-4P32-LW-SC<br />
ICN-4P32-SC<br />
IOP-4P32-LW-SC<br />
IOP-4P32-SC<br />
IOP-4P32-HL-90C-G<br />
GEL-3P32-RH-TP<br />
GEL-4P32-LW<br />
GEL-4P32-RH-TP<br />
ROP-4P32-LW-SC<br />
VOP-4P32-LW-SC<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
98 0.81 20<br />
112 0.88 20<br />
88 0.78 10<br />
102 0.95 10<br />
95 0.82 10<br />
81 1.03 10<br />
155 1.25 10<br />
98 0.81 20<br />
112 0.88 15<br />
88 0.78 10<br />
101 0.88 10<br />
95 0.82 10<br />
108 0.93 10<br />
151 1.25 10<br />
97-95 0.82 10<br />
112 0.97 10<br />
98-96 0.84 10<br />
110-107 0.93 10<br />
150-147 1.25 10<br />
107 0.89 20<br />
98 0.81 25<br />
108 0.89 20<br />
116 0.89 10<br />
116 0.89 10<br />
Line<br />
Current<br />
(Amps)<br />
0.82<br />
0.94<br />
0.73<br />
0.64<br />
0.80<br />
0.69<br />
1.30<br />
0.35<br />
0.41<br />
0.32<br />
0.37<br />
0.35<br />
0.38<br />
0.55<br />
0.81-0.34<br />
0.94-0.40<br />
0.82-0.35<br />
0.92-0.38<br />
1.27-0.54<br />
0.32<br />
0.29<br />
0.32<br />
0.98<br />
0.41<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
32/0<br />
32/0<br />
32/0<br />
32/0<br />
32/0<br />
Dim.<br />
B<br />
A<br />
B<br />
A<br />
B<br />
G<br />
A<br />
B<br />
Wiring<br />
Dia.<br />
*66<br />
65<br />
*66<br />
*66<br />
65<br />
*66<br />
*66<br />
65<br />
*66<br />
66<br />
ELECTRONIC<br />
FLUORESCENT<br />
Fig. A<br />
1.18"<br />
1.7"<br />
8.90"<br />
9.5"<br />
Fig. B<br />
Fig. G<br />
LAMP<br />
LINE<br />
* YEL<br />
* YEL<br />
WHITE<br />
BLACK<br />
BALLAST<br />
BLUE<br />
BLUE<br />
RED<br />
RED<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
LAMP<br />
BLUE<br />
BLUE<br />
BLUE<br />
*FOR SINGLE LAMP OPERATION, INSULATE<br />
YELLOW LEADS INDIVIDUALLY FOR 600V<br />
Diag. 39<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
BLUE<br />
BLUE<br />
LINE<br />
LAMP<br />
LAMP<br />
Diag. 65<br />
LINE<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
LAMP<br />
Diag. 63<br />
BLUE<br />
Diag. 64<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
LINE<br />
LAMP<br />
LAMP<br />
* For Single Lamp Operation, insulate unused<br />
blue lead for 600 volts<br />
* For Two Lamp Operation, insulate unused<br />
blue lead for 600 volts<br />
LINE<br />
WHITE<br />
BLACK<br />
YELLOW<br />
YELLOW<br />
BALLAST<br />
LAMP<br />
LAMP<br />
LAMP<br />
LAMP<br />
BLUE<br />
BLUE<br />
RED<br />
RED<br />
Diag. 66<br />
* For Three Lamp Operation, insulate unused<br />
blue lead for 600 volts<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-63
T8 Slimline<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 46 - 59W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
F72T8 (46W)<br />
120<br />
1 277<br />
120-277<br />
120<br />
2 277<br />
120-277<br />
F96T8/ES (57W)<br />
1<br />
2<br />
120<br />
277<br />
120-277<br />
347<br />
120<br />
277<br />
120-277<br />
347<br />
F96T8 (59W)<br />
1<br />
2<br />
Input<br />
Volts<br />
120<br />
277<br />
120-277<br />
347<br />
120<br />
277<br />
120-277<br />
347<br />
Lamp<br />
Starting<br />
Method<br />
IS<br />
IS<br />
IS<br />
IS<br />
IS<br />
IS<br />
Ballast<br />
Family<br />
Standard<br />
Centium<br />
Standard<br />
Centium<br />
REL-2P59-SC<br />
VEL-2P59-SC<br />
IOP-2P59-SC<br />
REL-2P59-SC<br />
VEL-2P59-SC<br />
IOP-2P59-SC<br />
58<br />
54<br />
90<br />
88<br />
Standard<br />
Centium<br />
Standard<br />
Centium<br />
Optanium<br />
Standard<br />
Standard<br />
Centium<br />
Standard<br />
Centium<br />
Optanium<br />
Standard<br />
Standard<br />
Centium<br />
Standard<br />
Centium<br />
Optanium<br />
Standard<br />
Standard<br />
Centium<br />
Standard<br />
Centium<br />
Optanium<br />
Standard<br />
Catalog Number<br />
REL-2P59-S-RH-TP<br />
REL-2P59-SC<br />
RCN-2P59<br />
VEL-2P59-S-RH-TP<br />
VEL-2P59-SC<br />
VCN-2P59<br />
IOP-2P59-SC<br />
GEL-2P59<br />
REL-2P59-S-RH-TP<br />
REL-2P59-SC<br />
RCN-2P59<br />
VEL-2P59-S-RH-TP<br />
VEL-2P59-SC<br />
VCN-2P59<br />
IOP-2P59-SC<br />
GEL-2P59<br />
REL-2P59-S-RH-TP<br />
REL-2P59-SC<br />
RCN-2P59<br />
VEL-2P59-S-RH-TP<br />
VEL-2P59-SC<br />
VCN-2P59<br />
IOP-2P59-SC<br />
GEL-2P59<br />
REL-2P59-S-RH-TP<br />
REL-2P59-SC<br />
RCN-2P59<br />
VEL-2P59-S-RH-TP<br />
VEL-2P59-SC<br />
VCN-2P59<br />
IOP-2P59-SC<br />
GEL-2P59<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
1.15 20<br />
1.09 10<br />
0.90<br />
0.92<br />
Max.<br />
THD<br />
%<br />
20<br />
10<br />
68 1.10 30<br />
69 1.05 20<br />
68 1.10 30<br />
69 1.05 20<br />
64 1.05 10<br />
70 1.10 30<br />
106 0.85 20<br />
106 0.88 10<br />
106 0.85 20<br />
106 0.88 10<br />
103 0.87 10<br />
108 0.88 20<br />
70 1.10 30<br />
71 1.05 20<br />
70 1.10 30<br />
71 1.05 20<br />
67 1.05 10<br />
72 1.10 30<br />
110 0.85 20<br />
110 0.88 10<br />
110 0.85 20<br />
110 0.88 10<br />
107 0.87 10<br />
110 0.88 20<br />
Line<br />
Current<br />
(Amps)<br />
0.54<br />
0.23<br />
0.46-0.20<br />
0.79<br />
0.34<br />
0.74-0.32<br />
0.60<br />
0.63<br />
0.26<br />
0.26<br />
0.56-0.25<br />
0.21<br />
0.90<br />
0.90<br />
0.39<br />
0.39<br />
0.86-0.37<br />
0.32<br />
0.62<br />
0.63<br />
0.27<br />
0.27<br />
0.56-0.25<br />
0.22<br />
0.94<br />
0.94<br />
0.41<br />
0.41<br />
0.91-0.39<br />
0.32<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
32/0<br />
32/0<br />
32/0<br />
32/0<br />
32/0<br />
32/0<br />
Dim.<br />
B<br />
B<br />
A<br />
B<br />
A<br />
B<br />
A<br />
A<br />
B<br />
A<br />
B<br />
A<br />
Wiring<br />
Dia.<br />
*64<br />
64<br />
*64<br />
64<br />
*64<br />
64<br />
• RCN and VCN ballasts will be phased out in 2006 and replaced by IOP-2P59-SC.<br />
• REL and VEL “Standard can” ballasts will be phased out in 2006 and replaced by “Small can” ballasts.<br />
See page 1-63 for Dimensions and Wiring Diagrams<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-64<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 44 - 86W Lamps<br />
T8/HO<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
F48T8/HO (44W)<br />
1 120-277<br />
2 120-277<br />
F60T8/HO (55W)<br />
1 120-277<br />
2 120-277<br />
F72T8/HO (65W)<br />
1 120-277<br />
120<br />
2 277<br />
120-277<br />
F96T8/HO (86W)<br />
1 120-277<br />
120<br />
2 277<br />
120-277<br />
Lamp<br />
Starting<br />
Method<br />
PS<br />
PS<br />
Ballast<br />
Family<br />
Centium<br />
Centium<br />
Catalog Number<br />
ICN-2S86<br />
ICN-2S86<br />
ICN-2S86<br />
ICN-2S86<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
59 1.02 20<br />
98 0.95 10<br />
70 1.00 20<br />
118 0.92 10<br />
Line<br />
Current<br />
(Amps)<br />
0.50-0.23<br />
0.84-0.36<br />
0.58-0.26<br />
1.04-0.45<br />
PS Centium ICN-2S86<br />
81 1.00 15 0.68-0.30<br />
REL-2S86<br />
1.11<br />
RS Standard<br />
130 0.92 20<br />
VEL-2S86<br />
0.48<br />
PS Centium ICN-2S86<br />
140 0.94 10 1.21-0.54<br />
PS Centium ICN-2S86<br />
100 1.00 10 0.84-0.36<br />
REL-2S86<br />
1.36<br />
RS Standard<br />
160 0.88 20<br />
VEL-2S86<br />
0.60<br />
PS Centium ICN-2S86<br />
185 0.95 10 1.57-0.68<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
-20/-29<br />
-20/-29<br />
-20/-29<br />
50/10<br />
-20/-29<br />
-20/-29<br />
50/10<br />
-20/-29<br />
Dim.<br />
C<br />
C<br />
C<br />
C<br />
Wiring<br />
Dia.<br />
39A<br />
21<br />
39A<br />
21<br />
39A<br />
21<br />
39A<br />
21<br />
ELECTRONIC<br />
FLUORESCENT<br />
1 25 /32”<br />
2 7 /8”<br />
11 3 /4”<br />
11 9 /64”<br />
Slimline Fig. Cand HO<br />
LAMP<br />
LINE<br />
BLACK<br />
WHITE<br />
YEL<br />
YEL<br />
BALLAST<br />
BLUE<br />
BLUE<br />
RED<br />
RED<br />
Diag. 39A<br />
For single lamp operation insulate<br />
yellow leads individually for 1000V<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-65
T10 and T12<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 25 - 40W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
F40T10 (40W)<br />
1<br />
120<br />
277<br />
120<br />
2 277<br />
347<br />
RS<br />
3<br />
120<br />
277<br />
F25T12 (25W - 36")<br />
1<br />
120<br />
277<br />
2<br />
120<br />
277<br />
RS<br />
3<br />
120<br />
277<br />
F30T12 (30W - 36")<br />
1<br />
120<br />
277<br />
2<br />
120<br />
277<br />
RS<br />
3<br />
120<br />
277<br />
Ballast<br />
Family<br />
Standard<br />
Standard<br />
Standard<br />
Catalog Number<br />
REL-1S40-SC<br />
VEL-1S40-SC<br />
REL-2S40-SC<br />
VEL-2S40-SC<br />
GEL-2S40-RH-TP<br />
REL-3S40-RH-TP<br />
VEL-3S40-RH-TP<br />
REL-1S40-SC<br />
VEL-1S40-SC<br />
REL-2S40-SC<br />
VEL-2S40-SC<br />
REL-3S40-RH-TP<br />
VEL-3S40-RH-TP<br />
REL-1S40-SC<br />
VEL-1S40-SC<br />
REL-2S40-SC<br />
VEL-2S40-SC<br />
REL-3S40-RH-TP<br />
VEL-3S40-RH-TP<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
35<br />
71<br />
72<br />
112<br />
28<br />
50<br />
80<br />
30<br />
60<br />
90<br />
Ballast<br />
Factor<br />
0.85<br />
0.85<br />
0.87<br />
0.85<br />
1.07<br />
1.01<br />
0.95<br />
0.98<br />
0.92<br />
0.95<br />
Max.<br />
THD<br />
%<br />
20<br />
20<br />
20<br />
Line<br />
Current<br />
(Amps)<br />
0.30<br />
0.13<br />
0.62<br />
0.25<br />
0.21<br />
0.95<br />
0.41<br />
0.24<br />
0.10<br />
0.44<br />
0.18<br />
0.69<br />
0.30<br />
0.27<br />
0.12<br />
0.51<br />
0.22<br />
0.78<br />
0.34<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
50/10<br />
50/10<br />
50/10<br />
Dim.<br />
B<br />
A<br />
B<br />
A<br />
B<br />
A<br />
Wiring<br />
Dia.<br />
20<br />
21<br />
30<br />
20<br />
21<br />
30<br />
20<br />
21<br />
30<br />
LAMP<br />
LAMP<br />
LAMP<br />
LINE<br />
RED<br />
RED<br />
BLUE/WHITE<br />
BLUE/WHITE<br />
BLACK<br />
WHITE<br />
BALLAST<br />
Diag. 30<br />
YELLOW<br />
YELLOW<br />
BLUE<br />
BLUE<br />
See page 1-67 for Dimensions<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-66<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 22 - 40W Lamps<br />
T10 and T12<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
F34T12, F34T12/U (34W)<br />
120<br />
1<br />
277<br />
Standard<br />
120<br />
AmbiStar<br />
PowrKut<br />
2<br />
RS<br />
Standard<br />
277<br />
PowrKut<br />
347<br />
120<br />
Standard<br />
3<br />
277<br />
F40T12, F40T12/U (40W)<br />
120<br />
1<br />
277<br />
Standard<br />
2<br />
3<br />
Input<br />
Volts<br />
120<br />
277<br />
347<br />
120<br />
277<br />
Lamp<br />
Starting<br />
Method<br />
RS<br />
Ballast<br />
Family<br />
AmbiStar<br />
PowrKut<br />
Standard<br />
PowrKut<br />
Standard<br />
Catalog Number<br />
REL-1S40-SC<br />
VEL-1S40-SC<br />
REL-2S40-SC<br />
RELB-2S40-SC<br />
RK-2S34-TP**<br />
VEL-2S40-SC<br />
VK-2S34-TP**<br />
GEL-2S40-RH-TP<br />
REL-3S40-RH-TP<br />
VEL-3S40-RH-TP<br />
REL-1S40-SC<br />
VEL-1S40-SC<br />
REL-2S40-SC<br />
RELB-2S40-SC<br />
RK-2S34-TP**<br />
VEL-2S40-SC<br />
VK-2S34-TP**<br />
GEL-2S40-RH-TP<br />
REL-3S40-RH-TP<br />
VEL-3S40-RH-TP<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
31<br />
60<br />
62<br />
60<br />
60<br />
60<br />
62<br />
91<br />
35<br />
71<br />
73<br />
68<br />
71<br />
68<br />
72<br />
107<br />
Ballast<br />
Factor<br />
0.88<br />
0.85<br />
0.85<br />
0.80<br />
0.85<br />
0.80<br />
0.87<br />
0.87<br />
0.85<br />
0.85<br />
0.85<br />
0.82<br />
0.85<br />
0.82<br />
0.87<br />
0.87<br />
Max.<br />
THD<br />
%<br />
20<br />
20<br />
Line<br />
Current<br />
(Amps)<br />
0.27<br />
0.12<br />
0.52<br />
0.53<br />
0.52<br />
0.22<br />
0.22<br />
0.18<br />
0.77<br />
0.33<br />
0.30<br />
0.13<br />
0.62<br />
0.62<br />
0.57<br />
0.25<br />
0.25<br />
0.21<br />
0.91<br />
0.39<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
50/10<br />
50/10<br />
Dim.<br />
B<br />
A<br />
B<br />
A<br />
B<br />
A<br />
B<br />
A<br />
Wiring<br />
Dia.<br />
20<br />
21<br />
30<br />
20<br />
21<br />
30<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
FC8T9 (22W Circline)<br />
1 120 IS Matchbox † RMB-1P26-S2 22 0.95 150 0.35 0/-18 S2 163<br />
† Matchbox ballasts are normal power factor except -H models which are high power factor.<br />
**For replacement use only.<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
S2 Model<br />
Fig. A<br />
1.18"<br />
8.90"<br />
9.5"<br />
1.7"<br />
Fig. B<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
See page 1-66 for Wiring Diagrams<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-67
T12 Slimline<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 55 - 75W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED C<br />
ELECTRONIC<br />
FLUORESCENT<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
F72T12 (55W)<br />
120<br />
1<br />
277<br />
120<br />
2<br />
277<br />
F96T12/ES (60W)<br />
120<br />
1<br />
277<br />
120<br />
2<br />
277<br />
F96T12 (75W)<br />
120<br />
1<br />
277<br />
120<br />
2<br />
277<br />
Lamp<br />
Starting<br />
Method<br />
IS<br />
IS<br />
IS<br />
Ballast<br />
Family<br />
Standard<br />
Standard<br />
Standard<br />
Catalog Number<br />
REL-2P60-S<br />
VEL-2P75-S<br />
REL-2P60-S<br />
VEL-2P75-S<br />
REL-2P60-S<br />
VEL-2P75-S<br />
REL-2P60-S<br />
VEL-2P75-S<br />
REL-2P60-S<br />
VEL-2P75-S<br />
REL-2P60-S<br />
VEL-2P75-S<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
70<br />
110<br />
70<br />
107<br />
85<br />
132<br />
Ballast<br />
Factor<br />
1.10<br />
0.92<br />
1.05<br />
0.85<br />
1.05<br />
0.85<br />
Max.<br />
THD<br />
%<br />
30<br />
20<br />
30<br />
20<br />
30<br />
20<br />
Line<br />
Current<br />
(Amps)<br />
0.62<br />
0.27<br />
0.93<br />
0.41<br />
0.62<br />
0.27<br />
0.88<br />
0.39<br />
0.75<br />
0.32<br />
1.13<br />
0.49<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
-20/-29<br />
-20/-29<br />
-20/-29<br />
Dim.<br />
C<br />
C<br />
C<br />
Wiring<br />
Dia.<br />
*64<br />
64<br />
*64<br />
64<br />
*64<br />
64<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
BLUE<br />
BLUE<br />
1 25 /32”<br />
LAMP<br />
LINE<br />
LAMP<br />
2 7 /8”<br />
11 3 /4”<br />
11 9 /64”<br />
Slimline Fig. Cand HO<br />
Diag. 64<br />
* For Single Lamp Operation, insulate unused<br />
blue lead for 600 volts<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
1-68<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 60 - 110W Lamps<br />
T12/HO<br />
HIGH POWER FACTOR<br />
SOUND RATED B<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
F48T12/HO (60W)<br />
120<br />
REL-2S110<br />
1.09<br />
2 RS Standard<br />
125 1.15 30<br />
-20/-29 C 21<br />
277<br />
VEL-2S110<br />
0.48<br />
F60T12/HO (75W)<br />
120<br />
REL-2S110<br />
1.29<br />
2 RS Standard 145 1.00 30<br />
-20/-29 C 21<br />
277<br />
VEL-2S110<br />
0.53<br />
F72T12/HO (85W)<br />
120<br />
REL-2S110<br />
1.40<br />
2 RS Standard 164 0.90 20<br />
-20/-29 C 21<br />
277<br />
VEL-2S110<br />
0.61<br />
F96T12/HO/ES (95W)<br />
120<br />
REL-2S110<br />
1.44<br />
2 RS Standard 170 0.89 20<br />
-20/-29 C 21<br />
277<br />
VEL-2S110<br />
0.63<br />
F96T12/HO (110W)<br />
120<br />
REL-2S110<br />
1.10<br />
1<br />
119 0.91 30<br />
39A<br />
277<br />
VEL-2S110<br />
0.48<br />
RS Standard<br />
-20/-29 C<br />
120<br />
REL-2S110<br />
1.74<br />
2<br />
205 0.89 20<br />
21<br />
277<br />
VEL-2S110<br />
0.76<br />
Max.<br />
THD<br />
%<br />
Dim.<br />
Wiring<br />
Dia.<br />
ELECTRONIC<br />
FLUORESCENT<br />
1 25 /32”<br />
2 7 /8”<br />
11 3 /4”<br />
11 9 /64”<br />
Slimline Fig. Cand HO<br />
LAMP<br />
LINE<br />
BLACK<br />
WHITE<br />
YEL<br />
YEL<br />
BALLAST<br />
BLUE<br />
BLUE<br />
RED<br />
RED<br />
Diag. 39A<br />
For single lamp operation insulate<br />
yellow leads individually for 1000V<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
1-69
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
NOTES<br />
ELECTRONIC<br />
FLUORESCENT<br />
1-70<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Contents<br />
Optanium Step-Dim . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 to 2-3<br />
AmbiStar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 to 2-5<br />
Mark 10 Powerline . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 to 2-10<br />
Mark 7 0-10V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11 to 2-16<br />
ROVR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17 to 2-21<br />
Compatible Controls . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22 to 2-23<br />
CONTROLLABLE<br />
Select the control you need for your application from a list of manufacturers<br />
that offer compatible controls for the Mark 7 0-10V and<br />
Mark 10 Powerline electronic dimming ballasts, as well as, ROVR digital<br />
addressable ballasts. The manufacturers that offer Mark 10 Powerline<br />
controls have built the control according to our specifications to<br />
assure the system is compatible. Part numbers and/or brands are<br />
listed along with the manufacturer’s phone number.<br />
Note: Refer to pages 8-24 to 8-26 for Ballast specifications.<br />
Corporate Offices<br />
(800) 322-2086<br />
Customer Support/Technical Service<br />
(800) 372-3331 • (+) 1 847 390-5000 (International)<br />
Visit our web site at www.advancetransformer.com<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 2-1
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - Optanium ® Step-Dim<br />
High-efficiency electronic ballasts for a T5 lighting systems<br />
Versatile and high-performing, <strong>Advance</strong>'s Optanium ® high-efficiency electronic ballasts optimize<br />
energy savings and are compatible with T5 high efficiency lamps.<br />
STEP DIMMING<br />
<strong>Advance</strong>'s Optanium family optimizes lumen-per-watt performance and delivers a high-efficiency<br />
solution for a broad range of commercial, industrial, and institutional applications.<br />
OPTANIUM<br />
Features<br />
Benefits<br />
Stepped-Dim capable<br />
Energy consumption reduced by 50%<br />
End-of-lamp-life protection<br />
Safely removes power to the lamp(s)<br />
Lamp auto-restrike circuitry and anti-arcing These and other standard features within the Optanium 2.0<br />
technology<br />
line reduce maintenance concerns and enhance safety<br />
PLUS 90 Protection ®<br />
<strong>Advance</strong>'s exclusive extended system warranty protection,<br />
which matches any lamp manufacturer's published lampballast<br />
system warranty, plus adds 90 days of additional<br />
warranty protection—on both the lamp and ballast!<br />
2-2<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 28W Lamps<br />
T5<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
Optanium <strong>Electronic</strong> Step-Dim Ballast<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Max/Min<br />
Ballast<br />
Factor<br />
Full Light Output<br />
THD %<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
F28T5 (28W)<br />
2<br />
120-277<br />
IntelliVolt<br />
*Available Q3 2006.<br />
PS<br />
Optanium<br />
IOP-2S28-95-SC-SD*<br />
IOP-2S28-115-SC-SD*<br />
TBD<br />
TBD<br />
TBD<br />
TBD<br />
TBD<br />
TBD TBD B 173<br />
TBD<br />
CONTROLLABLE OPTANIUM<br />
1.18"<br />
8.90"<br />
9.5"<br />
1.7"<br />
Fig. B<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
2-3
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - AmbiStar <br />
<strong>Electronic</strong> <strong>Ballasts</strong> for 4-pin Compact Fluorescent<br />
STEP DIMMING<br />
<strong>Advance</strong>'s family of electronic ballasts specifically designed for popular fluorescent applications<br />
in homes and other non-commercial environments brings all of the energy-efficient benefits of<br />
fluorescent lighting to residential and hospitality applications. FCC Class B EMI compliant and<br />
available for 4-pin CFL lamps. <strong>Advance</strong>'s AmbiStar ballasts are compact and lightweight, provide<br />
quick starting light and save users significant energy costs relative to alternative lighting sources.<br />
AMBISTAR<br />
Features<br />
Dimmable from any incandescent or<br />
Mark 10 Powerline dimmer<br />
Meets Energy Star ballast requirements<br />
Rated for use in 65°C ambient<br />
Benefits<br />
Utilizes simplicity of incandescent dimming<br />
Enables usage where Energy Star fixtures are<br />
required<br />
Low ballast temperature rise allows for higher ambient<br />
applications<br />
Designed in the Size 1 housing<br />
Small housing provides for design flexibility<br />
2-4<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 18 - 42W Lamps<br />
T4<br />
NORMAL POWER FACTOR<br />
SOUND RATED A<br />
AmbiStar <strong>Electronic</strong> Dimming Ballast<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Max/Min<br />
Ballast<br />
Factor<br />
Full Light Output<br />
CFQ18W/G24q - 18W CFL Quad Tube Lamp (PL-C18W/4P, F18DBX/4P, CF18DD/E)<br />
CFTR18W/GX24q - 18W CFL Triple Tube Lamp (PL-T18W, F18TBX/4P, CF18DT/E)<br />
REB-2S18-M1-BS-DIM*<br />
1 120<br />
TBD<br />
TBD<br />
REB-2S18-M1-LS-DIM*<br />
PS AmbiStar<br />
0.80/0.15 TBD<br />
REB-2S18-M1-BS-DIM*<br />
2 120<br />
TBD<br />
TBD<br />
REB-2S18-M1-LS-DIM*<br />
CFQ26W/G24q - 26W CFL Quad Tube Lamp (PL-C26W/4P, F26DBX/4P, CF26DD/E)<br />
CFTR26W/GX24q - 26W CFL Triple Tube Lamp (PL-T26W, F26TBX/4P, CF26DT/E)<br />
REB-2S26-M1-BS-DIM<br />
1 120<br />
TBD<br />
TBD<br />
REB-2S26-M1-LS-DIM<br />
PS AmbiStar<br />
0.80/0.15 TBD<br />
REB-2S26-M1-BS-DIM<br />
2 120<br />
53<br />
0.47<br />
REB-2S26-M1-LS-DIM<br />
50/10<br />
50/10<br />
Size 1<br />
Size 1<br />
138<br />
138<br />
CFTR32W/GX24q - 32W CFL Triple Tube Lamp (PL-T32W, F32TBX/4P, CF32DT/E)<br />
1 120 PS AmbiStar<br />
REB-2S26-M1-BS-DIM<br />
REB-2S26-M1-LS-DIM<br />
TBD 0.80/0.15 TBD TBD 50/10 Size 1 138<br />
CFTR42W/GX24q - 42W CFL Triple Tube Lamp (PL-T42W, F42TBX/4P, CF42DT/E)<br />
1 120 PS AmbiStar<br />
REB-2S26-M1-BS-DIM<br />
REB-2S26-M1-LS-DIM<br />
TBD 0.80/0.15 TBD TBD 50/10 Size 1 138<br />
THD %<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
CONTROLLABLE AMBISTAR<br />
Some lamp manufacturers recommend burning in new lamps 100 hours at full light output before dimming. Consult lamp manufacturer.<br />
<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauges from AWG 16 - 20.<br />
Ballast dimmable from any incandescent or Mark 10 Powerline dimmer.<br />
*Available Q4 2006.<br />
Refer to page 1-15 for information on remote/tandem<br />
wiring and lead length extension<br />
ONLY USE 4-PIN RAPID-START SOCKETS<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
2-5
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - Mark 10 ® Powerline<br />
Mark 10 ® Powerline <strong>Electronic</strong> Dimming <strong>Ballasts</strong> for Linear Fluorescent, 4-Pin CFL,<br />
and T5/HO Lamps<br />
DIMMING<br />
<strong>Advance</strong>'s Mark 10 Powerline electronic dimming ballasts for Linear Fluorescent, 4-Pin CFL, and<br />
T5/HO Lamps are the full-range electronic dimming ballasts for fluorescent lighting systems.<br />
Flexible and easy to install because they require no additional wiring, Mark 10 Powerline ballasts<br />
combine the long life and energy efficiency of fluorescent technology with the controllability and<br />
full-range dimming capabilities of incandescent systems.<br />
MARK 10 Powerline<br />
Mark 10 Powerline ballasts are ideal in such applications as conference rooms, offices,<br />
auditoriums, educational facilities, hotels, restaurants, and department stores as well as other<br />
new construction or retrofit installations where dimming is desired.<br />
Features<br />
Benefits<br />
100% to 5% full-range continuous<br />
dimming (down to 1% in T5/HO models)<br />
Energy-efficient design<br />
Absence of additional control leads<br />
Programmed Start Ignition<br />
Lamp ignition at any light setting,<br />
including the 5% level (1% in T5/HO models)<br />
Increases system flexibility and enhances visual comfort<br />
Delivers up to 65% energy savings over standard<br />
Fixed Output T8 ballasts<br />
Enhances ease of installation (as no extra wiring is<br />
required) and is also highly flexible and compatible<br />
with a wide variety of controls by a broad range of<br />
control manufacturers<br />
Provides extended lamp life in frequent starting<br />
applications<br />
Eliminates the need to ramp up to 100% light output<br />
when starting<br />
2-6<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 18 - 70W Lamps<br />
T4<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
Mark 10 Powerline <strong>Electronic</strong> Dimming Ballast<br />
No. of<br />
Lamps<br />
CFQ18W/G24q - 18W CFL Quad Tube Lamp (PL-C18W/4P, F18DBX/4P, CF18DD/E)<br />
CFTR18W/GX24q - 18W CFL Triple Tube Lamp (PL-T18W, F18TBX/4P, CF18DT/E)<br />
120<br />
REZ-1Q18-M2-BS<br />
0.18<br />
REZ-1Q18-M2-LD<br />
1<br />
22/7<br />
277<br />
VEZ-1Q18-M2-BS<br />
Mark 10<br />
0.07<br />
VEZ-1Q18-M2-LD<br />
PS<br />
1.00/0.05 10<br />
120<br />
Powerline REZ-2Q18-M2-BS<br />
0.36<br />
REZ-2Q18-M2-LD<br />
2<br />
43/14<br />
277<br />
VEZ-2Q18-M2-BS<br />
0.16<br />
VEZ-2Q18-M2-LD<br />
CFQ26W/G24q - 26W CFL Quad Tube Lamp (PL-C26W/4P, F26DBX/4P, CF26DD/E)<br />
CFTR26W/GX24q - 26W CFL Triple Tube Lamp (PL-T26W, F26TBX/4P, CF26DT/E)<br />
1<br />
2<br />
Input<br />
Volts<br />
120<br />
277<br />
120<br />
277<br />
Lamp<br />
Starting<br />
Method<br />
PS<br />
Note: ➀ Replacement/Retrofit Ballast Kits indicated by Bold Type with suffix -K<br />
are available to distributers. Refer to page__.<br />
For ballast dimensions<br />
see page 2-8<br />
Mark 10<br />
Powerline<br />
REZ-1T42-M2-BS<br />
REZ-1T42-M2-LD<br />
REZ-1T42-M2-LD-K ➀<br />
VEZ-1T42-M2-BS<br />
VEZ-1T42-M2-LD<br />
VEZ-1T42-M2-LD-K ➀<br />
REZ-2Q26-M2-BS<br />
REZ-2Q26-M2-LD<br />
REZ-2Q26-M2-LD-K ➀<br />
VEZ-2Q26-M2-BS<br />
VEZ-2Q26-M2-LD<br />
VEZ-2Q26-M2-LD-K ➀<br />
31/8<br />
58/16<br />
1.00/0.05 10<br />
CFTR32W/GX24q - 32W CFL Triple Tube Lamp (PL-T32W, F32TBX/4P, CF32DT/E)<br />
REZ-1T42-M2-BS<br />
120<br />
REZ-1T42-M2-LD<br />
REZ-1T42-M2-LD-K ➀<br />
1<br />
38/9<br />
VEZ-1T42-M2-BS<br />
277<br />
Mark 10<br />
PS<br />
VEZ-1T42-M2-LD<br />
1.00/0.05 10<br />
Powerline VEZ-1T42-M2-LD-K ➀<br />
120<br />
REZ-2T42-M3-BS<br />
REZ-2T42-M3-LD<br />
2<br />
76/20<br />
277<br />
VEZ-2T42-M3-BS<br />
VEZ-2T42-M3-LD<br />
CFTR42W/GX24q - 42W CFL Triple Tube Lamp (PL-T42W, F42TBX/4P, CF42DT/E)<br />
REZ-1T42-M2-BS<br />
120<br />
REZ-1T42-M2-LD<br />
REZ-1T42-M2-LD-K ➀<br />
1<br />
49/10<br />
VEZ-1T42-M2-BS<br />
277<br />
Mark 10<br />
PS<br />
VEZ-1T42-M2-LD<br />
1.00/0.05 10<br />
Powerline VEZ-1T42-M2-LD-K ➀<br />
REZ-2T42-M3-BS<br />
120<br />
2<br />
REZ-2T42-M3-LD<br />
98/20<br />
VEZ-2T42-M3-BS<br />
277<br />
VEZ-2T42-M3-LD<br />
CFTR57W/GX24q - 57W CFL Triple Tube Lamp (PL-T57W, F57QBX/4P, CF57DT/E)<br />
120<br />
REZ-2T42-M3-BS<br />
Mark 10 REZ-2T42-M3-LD<br />
1 PS<br />
66/18 1.00/0.05 10<br />
277<br />
Powerline VEZ-2T42-M3-BS<br />
VEZ-2T42-M3-LD<br />
CFTR70W/GX24q - 70W CFL Triple Tube Lamp (F70QBX/4P, CF70DT/E)<br />
120<br />
1 PS<br />
277<br />
Ballast<br />
Family<br />
Mark 10<br />
Powerline<br />
Catalog Number<br />
REZ-2T42-M3-BS<br />
REZ-2T42-M3-LD<br />
VEZ-2T42-M3-BS<br />
VEZ-2T42-M3-LD<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Max/Min<br />
Ballast<br />
Factor<br />
80/18 1.00/0.05 10<br />
Refer to page 1-15 for information on remote/tandem<br />
wiring and lead length extension<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
Full Light Output<br />
THD %<br />
Line<br />
Current<br />
(Amps)<br />
0.26<br />
0.11<br />
0.48<br />
0.21<br />
0.32<br />
0.14<br />
0.64<br />
0.28<br />
0.41<br />
0.55<br />
0.24<br />
50/10 Size 2<br />
50/10 Size 2<br />
50/10<br />
0.18 50/10<br />
0.82<br />
0.36<br />
0.67<br />
0.29<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Size 2<br />
Size 3<br />
Size 2<br />
Size 3<br />
Wiring<br />
Dia.<br />
134<br />
132<br />
134<br />
132<br />
134<br />
132<br />
134<br />
132<br />
50/10 Size 3 134<br />
50/10 Size 3 134<br />
Some lamp manufacturers recommend burning in new lamps 100 hours at full light<br />
output before dimming. Consult lamp manufacturer.<br />
<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauges from AWG 16 - 20.<br />
ONLY USE 4-PIN RAPID-START SOCKETS<br />
Use compatible Mark 10 Powerline controls<br />
only as referenced on page 2-22 & 2-23<br />
CONTROLLABLE MARK 10<br />
POWERLINE<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
2-7
FT5<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 24 - 55W Lamps<br />
Mark 10 Powerline <strong>Electronic</strong> Dimming Ballast<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Max/Min<br />
Ballast<br />
Factor<br />
FT24W/2G11 - 24/27WW Long Twin Tube Lamp (PL-L24W, F27BX/RS, FT24DL)<br />
Full Light Output<br />
THD %<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
CONTROLLABLE<br />
MARK 10<br />
POWERLINE<br />
1<br />
2<br />
FT36W/2G11 - 36/39W Long Twin Tube Lamp (PL-L36W, F39BX/RS, FT36DL)<br />
120<br />
REZ-1TTS40-SC<br />
1<br />
38/9<br />
277<br />
Mark 10 VEZ-1TTS40-SC<br />
PS<br />
120<br />
Powerline REZ-2TTS40-SC<br />
2<br />
75/16<br />
277<br />
VEZ-2TTS40-SC<br />
1.00/0.05 10<br />
FT40W/2G11/RS - 40W Long Twin Tube Lamp (PL-L40W, F40BX, FT40DL/RS)<br />
120<br />
REZ-1TTS40-SC<br />
1<br />
41/10<br />
277<br />
Mark 10 VEZ-1TTS40-SC<br />
PS<br />
120<br />
Powerline REZ-2TTS40-SC<br />
2<br />
80/17<br />
277<br />
VEZ-2TTS40-SC<br />
1.00/0.05 10<br />
FT55W/2G11 - 55W Long Twin Tube Lamp (F55BX, FT55DL)<br />
1<br />
2<br />
120-277<br />
IntelliVolt<br />
120<br />
277<br />
120<br />
277<br />
PS<br />
PS<br />
Mark 10<br />
Powerline<br />
Mark 10<br />
Powerline<br />
IEZ-124-D*<br />
IEZ-2S24-D<br />
REZ-154<br />
VEZ-154<br />
REZ-2S54<br />
VEZ-2S54<br />
TBD<br />
57/16<br />
59/13<br />
114/24<br />
1.00/0.05 10<br />
0.90/0.05 10<br />
TBD<br />
0.48-0.21<br />
0.32<br />
0.14<br />
0.64<br />
0.27<br />
0.32<br />
0.15<br />
0.68<br />
0.30<br />
0.50<br />
0.22<br />
0.96<br />
0.42<br />
50/10 D<br />
50/10 B<br />
50/10 B<br />
50/10 D<br />
134<br />
132<br />
134<br />
132<br />
134<br />
132<br />
134<br />
132<br />
Burn in new lamps 100 hours at full light before dimming.<br />
<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauge AWG 16-20.<br />
*Available Q4 2006.<br />
3.00"<br />
Size 2 Enclosure<br />
3.00"<br />
1.29"<br />
1.29" 2.00"<br />
4.20"<br />
4.60"<br />
4.20"<br />
4.60"<br />
1.18"<br />
8.90"<br />
9.5"<br />
-LD<br />
-BS<br />
1.7"<br />
Fig. B<br />
Fig. D<br />
Includes connectors with no leads<br />
3.00"<br />
Size 3 Enclosure<br />
1.29" 2.00"<br />
3.00"<br />
1.29"<br />
5.5"<br />
6.0"<br />
5.5"<br />
6.0" -BS<br />
Diag. 134 Diag. 132<br />
Refer to page 1-15 for information on remote/tandem<br />
wiring and lead length extension<br />
Use compatible Mark 10 Powerline controls<br />
only as referenced on page 2-22 & 2-23<br />
-LD<br />
(Dual connector for input only)<br />
ONLY USE RAPID-START SOCKETS<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
2-8<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 24 - 55W Lamps<br />
T5/HO<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
Mark 10 Powerline <strong>Electronic</strong> Dimming Ballast<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Max/Min<br />
Ballast<br />
Factor<br />
Full Light Output<br />
THD %<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
F24T5/HO (24W)<br />
1<br />
2<br />
F54T5/HO (54W)<br />
1<br />
2<br />
FC12T5/HO (55W)<br />
1<br />
2<br />
120-277<br />
IntelliVolt<br />
120<br />
277<br />
120<br />
277<br />
120<br />
277<br />
120<br />
277<br />
PS<br />
PS<br />
PS<br />
Mark 10<br />
Powerline<br />
Mark 10<br />
Powerline<br />
Mark 10<br />
Powerline<br />
IEZ-124-D*<br />
IEZ-2S24-D<br />
REZ-154<br />
VEZ-154<br />
REZ-2S54<br />
VEZ-2S54<br />
REZ-154<br />
VEZ-154<br />
REZ-2S54<br />
VEZ-2S54<br />
TBD<br />
57/16<br />
63/13<br />
125/24<br />
59/13<br />
114/24<br />
1.00/0.05<br />
1.00/0.03<br />
0.90/0.03<br />
10<br />
10<br />
10<br />
TBD<br />
0.48-0.21<br />
0.53<br />
0.23<br />
1.05<br />
0.45<br />
0.50<br />
0.22<br />
0.96<br />
0.42<br />
50/10<br />
50/10<br />
50/10<br />
D<br />
D<br />
D<br />
152<br />
153<br />
152<br />
153<br />
152<br />
153<br />
CONTROLLABLE MARK 10<br />
POWERLINE<br />
<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauge AWG 16-20.<br />
*Available Q4 2006.<br />
ONLY USE RAPID-START SOCKETS<br />
Diag. 152<br />
Fig. D<br />
Includes connectors with no leads<br />
Diag. 153<br />
Use compatible Mark 10 Powerline controls<br />
only as referenced on page 2-22 & 2-23<br />
Refer to page 1-15 for information on remote/tandem<br />
wiring and lead length extension<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
2-9
T8<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 17 - 32W Lamps<br />
Mark 10 Powerline <strong>Electronic</strong> Dimming Ballast<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
CONTROLLABLE<br />
MARK 10<br />
POWERLINE<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
F17T8, FBO16T8 (17W)<br />
120<br />
1<br />
277<br />
120<br />
Mark 10<br />
2<br />
PS<br />
277<br />
Powerline<br />
120<br />
3<br />
277<br />
F25T8, FBO24T8 (25W)<br />
Ballast<br />
Family<br />
120<br />
1<br />
277<br />
120<br />
Mark 10<br />
2<br />
PS<br />
277<br />
Powerline<br />
120<br />
3<br />
277<br />
F32T8, FBO31T8, F32T8/U6 (32W)<br />
120<br />
1<br />
277<br />
120<br />
Mark 10<br />
2<br />
PS<br />
277<br />
Powerline<br />
120<br />
3<br />
277<br />
Catalog Number<br />
REZ-132-SC 0.20<br />
24/7<br />
VEZ-132-SC<br />
0.09<br />
152<br />
REZ-2S32-SC<br />
0.32<br />
38/13 1.05/0.05 10<br />
VEZ-2S32-SC<br />
0.14<br />
50/10 B 153<br />
REZ-3S32-SC<br />
0.47<br />
56/18<br />
VEZ-3S32-SC<br />
0.21<br />
155<br />
REZ-132-SC<br />
VEZ-132-SC<br />
REZ-2S32-SC<br />
VEZ-2S32-SC<br />
REZ-3S32-SC<br />
VEZ-3S32-SC<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
30/7<br />
55/13<br />
79/19<br />
Max/Min<br />
Ballast<br />
Factor<br />
Full Light Output<br />
THD %<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
1.05/0.05 10<br />
0.26<br />
0.11<br />
0.46<br />
0.20<br />
0.66<br />
0.29<br />
50/10 B<br />
Wiring<br />
Dia.<br />
REZ-132-SC 0.29<br />
35/9<br />
VEZ-132-SC<br />
0.13<br />
152<br />
REZ-2S32-SC<br />
0.57<br />
68/15 1.00/0.05 10<br />
VEZ-2S32-SC<br />
0.25<br />
50/10 B 153<br />
REZ-3S32-SC<br />
0.86<br />
102/20<br />
VEZ-3S32-SC<br />
0.37<br />
155<br />
152<br />
153<br />
155<br />
ONLY USE RAPID-START SOCKETS<br />
Diag. 152<br />
1.18"<br />
8.90"<br />
9.5"<br />
1.7"<br />
Fig. B<br />
Diag. 153<br />
Refer to page 1-15 for information on remote/tandem<br />
wiring and lead length extension<br />
Use compatible Mark 10 Powerline controls<br />
only as referenced on page 2-22 & 2-23<br />
Diag. 155<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
2-10<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - Mark 7 ® 0-10 Volt<br />
0-10V <strong>Electronic</strong> Dimming <strong>Ballasts</strong> for Linear Fluorescent, 4-Pin CFL, and T5/HO Lamps<br />
<strong>Advance</strong>'s Mark 7 0-10V series of dimmable electronic ballasts for Linear Fluorescent, 4-Pin<br />
CFL, and T5/HO Lamps represent an affordable, flexible, and versatile dimming solution for a<br />
broad range of commercial, institutional, and retail applications. Ideal for energy management<br />
systems, Mark 7 0-10V ballasts offer full range continuous dimming and fully support sustainable<br />
(green) design.<br />
Mark 7 0-10V ballasts are ideal in such applications as conference rooms, auditoriums, educational<br />
facilities, hotels, restaurants, and department stores as well as other new construction or<br />
retrofit installations where dimming is desired.<br />
DIMMING MARK 70-10V<br />
Features<br />
100% to 5% full-range continuous<br />
dimming (down to 1% in T5/HO models)<br />
Energy-efficient design<br />
Direct operation from a 0-10V DC control<br />
signal<br />
Programmed Start ignition<br />
IntelliVolt ® multiple-voltage technology<br />
enabling operation at any input voltage<br />
from 120 to 277 volts, 50/60Hz<br />
Benefits<br />
Increases system flexibility and enhances visual comfort<br />
Delivers up to 65% energy savings over standard<br />
Fixed Output T8 ballasts<br />
Enables the need for fewer controls and allows for<br />
direct use of daylight harvesting and other low<br />
voltage controls<br />
Provides extended lamp life in frequent starting<br />
applications<br />
Enhances accuracy of ordering and reduces SKU<br />
requirements<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 2-11
T4<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 13 - 70W Lamps<br />
Mark 7 0-10V <strong>Electronic</strong> Dimming Ballast<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
CONTROLLABLE<br />
MARK 70-10V<br />
No. of<br />
Lamps<br />
CFQ13W/G24q - 13W CFL Quad Tube Lamp (PL-C13W/4P, F13DBX/4P, CF13DD/E)<br />
CFTR13W/GX24q - 13W CFL Triple Tube Lamp (F13TBX/4P, CF13DT/E)<br />
1<br />
2<br />
120-277<br />
IntelliVolt<br />
PS<br />
Mark 7<br />
0-10V<br />
IZT-2S26-M5-BS<br />
IZT-2S26-M5-LD<br />
IZT-2S26-M5-BS<br />
IZT-2S26-M5-LD<br />
CFQ18W/G24q - 18W CFL Quad Tube Lamp (PL-C18W/4P, F18DBX/4P, CF18DD/E)<br />
CFTR18W/GX24q - 18W CFL Triple Tube Lamp (PL-T18W, F18TBX/4P, CF18DT/E)<br />
1<br />
2<br />
120-277<br />
IntelliVolt<br />
PS<br />
Mark 7<br />
0-10V<br />
IZT-2S26-M5-BS<br />
IZT-2S26-M5-LD<br />
IZT-2S26-M5-BS<br />
IZT-2S26-M5-LD<br />
CFQ26W/G24q - 26W CFL Quad Tube Lamp (PL-C26W/4P, F26DBX/4P, CF26DD/E)<br />
CFTR26W/GX24q - 26W CFL Triple Tube Lamp (PL-T26W, F26TBX/4P, CF26DT/E)<br />
1<br />
2<br />
120-277<br />
IntelliVolt<br />
PS<br />
Mark 7<br />
0-10V<br />
IZT-2S26-M5-BS<br />
IZT-2S26-M5-LD<br />
IZT-2S26-M5-BS<br />
IZT-2S26-M5-LD<br />
CFTR32W/GX24q - 32W CFL Triple Tube Lamp (PL-T32W, F32TBX/4P, CF32DT/E)<br />
1<br />
2<br />
120-277<br />
IntelliVolt<br />
PS<br />
Mark 7<br />
0-10V<br />
IZT-2S26-M5-BS<br />
IZT-2S26-M5-LD<br />
IZT-2T42-M5-BS<br />
IZT-2T42-M5-LD<br />
CFTR42W/GX24q - 42W CFL Triple Tube Lamp (PL-T42W, F42TBX/4P, CF42DT/E)<br />
1<br />
2<br />
Input<br />
Volts<br />
120-277<br />
IntelliVolt<br />
Lamp<br />
Starting<br />
Method<br />
PS<br />
Ballast<br />
Family<br />
Mark 7<br />
0-10V<br />
Catalog Number<br />
IZT-2S26-M5-BS<br />
IZT-2S26-M5-LD<br />
IZT-2T42-M5-BS<br />
IZT-2T42-M5-LD<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
CFTR57W/GX24q - 57W CFL Triple Tube Lamp (PL-T57W, F57QBX/4P, CF57DT/E)<br />
120-277<br />
Mark 7 IZT-2T42-M5-BS<br />
1 PS<br />
65/16 1.00/0.03 10 0.55-0.24 50/10 Size 5 58A<br />
IntelliVolt<br />
0-10V IZT-2T42-M5-LD<br />
CFTR70W/GX24q - 70W CFL Triple Tube Lamp (F70QBX/4P, CF70DT/E)<br />
120-277<br />
Mark 7 IZT-2T42-M5-BS<br />
1 PS<br />
75/16 1.00/0.03 10 0.63-0.27 50/10 Size 5 58A<br />
IntelliVolt<br />
0-10V IZT-2T42-M5-LD<br />
18/6<br />
32/19<br />
20/7<br />
41/11<br />
28/8<br />
49/13<br />
34/9<br />
75/19<br />
46/9<br />
98/18<br />
Max/Min<br />
Ballast<br />
Factor<br />
THD %<br />
1.00/0.03 10<br />
1.00/0.03 10<br />
1.00/0.03 10<br />
1.00/0.03 10<br />
1.00/0.03 10<br />
Full Light Output<br />
Line<br />
Current<br />
(Amps)<br />
0.14-0.07<br />
0.26-0.12<br />
0.15-0.08<br />
0.32-0.15<br />
0.22-0.10<br />
0.41-0.18<br />
0.28-0.13<br />
0.63-0.21<br />
0.38-0.17<br />
0.82-0.36<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
50/10 Size 5<br />
50/10 Size 5<br />
50/10 Size 5<br />
50/10 Size 5<br />
50/10 Size 5<br />
Wiring<br />
Dia.<br />
58A<br />
59A<br />
58A<br />
59A<br />
58A<br />
59A<br />
58A<br />
59A<br />
58A<br />
59A<br />
Some lamp manufacturers recommend burning in new lamps 100 hours at<br />
full light output before dimming. Consult lamp manufacturer.<br />
<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauges from AWG 16 - 20.<br />
BLACK<br />
LINE<br />
WHITE<br />
CLASS 1 OR 2 VIOLET (+)<br />
CIRCUIT { GREY (-)<br />
10V, 0.5 mA<br />
BALLAST<br />
RED<br />
BLUE<br />
BLACK<br />
LINE<br />
WHITE<br />
CLASS 1 OR 2 VIOLET (+)<br />
CIRCUIT { GREY (-)<br />
10V, 0.5 mA<br />
BALLAST<br />
RED<br />
YELLOW<br />
BLUE<br />
ONLY USE 4-PIN RAPID-START SOCKETS<br />
Mark 7 0-10V Control Wiring (Grey and Violet)<br />
Wire Size Maximum Length (Ft.)<br />
AWG-16 800<br />
AWG-18 500<br />
AWG-20 320<br />
Diag. 58A<br />
For ballast dimensions<br />
see page 2-13<br />
Diag. 59A<br />
Refer to page 1-15 for information on remote/tandem<br />
wiring and lead length extension<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
2-12<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 36 - 80W Lamps<br />
FT5<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
Mark 7 0-10V <strong>Electronic</strong> Dimming Ballast<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
FT36W/2G11 - 36/39W Long Twin Tube Lamp (PL-L36W, F39BX/RS, FT36DL)<br />
120-277<br />
Mark 7<br />
2 PS<br />
IZT-2TTS40-SC 75/16 1.00/0.03 10 0.64-0.27 50/10 B 59A<br />
IntelliVolt<br />
0-10V<br />
FT40W/2G11/RS - 40W Long Twin Tube Lamp (PL-L40W, F40BX, FT40DL/RS)<br />
120<br />
RZT-1TTS40<br />
0.32<br />
1<br />
38/11<br />
58A<br />
277<br />
VZT-1TTS40<br />
0.14<br />
A<br />
120<br />
Mark 7 RZT-2TTS40<br />
0.64<br />
PS<br />
1.00/0.05 10<br />
50/10<br />
277<br />
0-10V VZT-2TTS40<br />
0.28<br />
2<br />
76/16<br />
59A<br />
120-277<br />
IZT-2TTS40-SC<br />
0.64-0.28<br />
B<br />
IntelliVolt<br />
FT55W/2G11 - 55W Long Twin Tube Lamp (F55BX, FT55DL)<br />
120<br />
RZT-154<br />
1<br />
59/13<br />
277<br />
Mark 7 VZT-154<br />
PS<br />
120<br />
0-10V RZT-2S54<br />
2<br />
114/24<br />
277<br />
VZT-2S54<br />
FT80W/2G11 - 80W Long Twin Tube Lamp (PL-L80W, FT80)<br />
Mark 7<br />
2 277 PS<br />
VZT-180<br />
0-10V<br />
Max/Min<br />
Ballast<br />
Factor<br />
THD %<br />
0.90/0.30 10<br />
Full Light Output<br />
Line<br />
Current<br />
(Amps)<br />
0.50<br />
0.22<br />
0.96<br />
0.42<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
50/10 D<br />
Wiring<br />
Dia.<br />
58A<br />
59A<br />
94/16 1.00/0.03 10 0.34 50/10 D 58A<br />
CONTROLLABLE MARK 70-10V<br />
Burn in new lamps 100 hours at full light output before dimming.<br />
<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauge AWG 16-20.<br />
ONLY USE RAPID-START SOCKETS<br />
BLACK<br />
LINE<br />
WHITE<br />
CLASS 1 OR 2 VIOLET (+)<br />
CIRCUIT { GREY (-)<br />
10V, 0.5 mA<br />
BALLAST<br />
RED<br />
BLUE<br />
BLACK<br />
LINE<br />
WHITE<br />
CLASS 1 OR 2 VIOLET (+)<br />
CIRCUIT { GREY (-)<br />
10V, 0.5 mA<br />
BALLAST<br />
RED<br />
YELLOW<br />
BLUE<br />
Fig. A<br />
Diag. 58A<br />
Diag. 59A<br />
Fig. D<br />
Includes connectors with no leads<br />
Size 5<br />
3.00" (76.4)<br />
1.18" (30.0)<br />
3.00" (76.4) 2.00" (50.8)<br />
1.18" (30.0)<br />
M5<br />
4.20" (106.7)<br />
4.55" (116.6)<br />
-BS<br />
1.18"<br />
1.7"<br />
8.90"<br />
9.5"<br />
Fig. B<br />
Use compatible low voltage controls<br />
only as referenced on page 2-22 & 2-23<br />
4.20" (106.7)<br />
4.55" (116.6)<br />
-LD<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
Refer to page 1-15 for information on remote/tandem<br />
wiring and lead length extension<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
2-13
T5/HO<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 54 - 80W Lamps<br />
Mark 7 0-10V <strong>Electronic</strong> Dimming Ballast<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Max/Min<br />
Ballast<br />
Factor<br />
Full Light Output<br />
THD %<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
F54T5/HO (54W)<br />
CONTROLLABLE<br />
1<br />
2<br />
120<br />
277<br />
120<br />
277<br />
F80T5/HO (80W)<br />
PS<br />
1 277 PS<br />
Mark 7<br />
0-10V<br />
Mark 7<br />
0-10V<br />
RZT-154<br />
VZT-154<br />
RZT-2S54<br />
VZT-2S54<br />
VZT-180<br />
63/13<br />
125/24<br />
1.00/0.03<br />
94/18 1.00/0.03<br />
10<br />
10<br />
0.53<br />
0.23<br />
1.05<br />
0.45<br />
0.34<br />
50/10<br />
50/10<br />
D<br />
D<br />
55A<br />
56A<br />
55A<br />
MARK 70-10V<br />
FC12T5/HO (55W)<br />
120<br />
1<br />
277<br />
PS<br />
120<br />
2<br />
277<br />
Mark 7<br />
0-10V<br />
RZT-154<br />
VZT-154<br />
RZT-2S54<br />
VZT-2S54<br />
59/13<br />
114/24<br />
0.90/0.03<br />
10<br />
0.50<br />
0.22<br />
0.96<br />
0.42<br />
50/10<br />
D<br />
55A<br />
56A<br />
<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauge AWG 16-20.<br />
ONLY USE RAPID-START SOCKETS<br />
Mark 7 0-10V Control Wiring (Grey and Violet)<br />
Wire Size Maximum Length (Ft.)<br />
AWG-16 800<br />
AWG-18 500<br />
AWG-20 320<br />
Fig. D<br />
Includes connectors with no leads<br />
Use compatible low voltage controls<br />
only as referenced on page 2-22 & 2-23<br />
LINE<br />
CLASS 1 OR 2<br />
CIRCUIT<br />
10V, 0.5 mA<br />
BLACK<br />
WHITE<br />
VIOLET (+)<br />
{ GREY (-)<br />
BALLAST<br />
RED<br />
BLUE<br />
LINE<br />
CLASS 1 OR 2<br />
CIRCUIT<br />
10V, 0.5 mA<br />
BLACK<br />
WHITE<br />
VIOLET (+)<br />
{ GREY (-)<br />
BALLAST<br />
RED<br />
BLUE<br />
YELLOW<br />
LAMP<br />
LAMP<br />
LAMP<br />
Diag. 55A<br />
Diag. 56A<br />
Refer to page 1-15 for information on remote/tandem<br />
wiring and lead length extension<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
2-14<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 17 - 25W Lamps<br />
T8<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
Mark 7 0-10V <strong>Electronic</strong> Dimming Ballast<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Max/Min<br />
Ballast<br />
Factor<br />
Full Light Output<br />
THD %<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
F17T8, FBO16T8 (17W)<br />
1 IZT-132-SC<br />
20/7 0.16-0.07 55A<br />
2<br />
3<br />
120-277<br />
IntelliVolt<br />
PS<br />
F25T8, FBO24T8 (25W)<br />
1<br />
2<br />
3<br />
120-277<br />
IntelliVolt<br />
PS<br />
Mark 7<br />
0-10V<br />
Mark 7<br />
0-10V<br />
IZT-2S32-SC<br />
IZT-3S32-SC<br />
IZT-132-SC<br />
IZT-2S32-SC<br />
IZT-3S32-SC<br />
36/11<br />
56/18<br />
28/8<br />
52/12<br />
79/19<br />
1.00/0.03 10 0.30-0.13 50/10 B<br />
1.00/0.03<br />
0.46-0.20<br />
0.24-0.11<br />
0.43-0.19<br />
10 50/10<br />
0.65-0.28<br />
B<br />
56A<br />
57A<br />
55A<br />
56A<br />
57A<br />
CONTROLLABLE MARK 70-10V<br />
4<br />
IZT-4S32<br />
96/22<br />
0.88/0.03<br />
0.77-0.35<br />
D<br />
16A<br />
<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauge AWG 16-20.<br />
Fig. A<br />
1.18"<br />
8.90"<br />
9.5"<br />
1.7"<br />
Fig. B<br />
ONLY USE RAPID-START SOCKETS<br />
Mark 7 0-10V Control Wiring (Grey and Violet)<br />
Wire Size Maximum Length (Ft.)<br />
AWG-16 800<br />
Fig. G<br />
AWG-18 500<br />
AWG-20 320<br />
AWG-22 200<br />
AWG-24 120<br />
Refer to page 1-15 for information on remote/tandem<br />
wiring and lead length extension<br />
Fig. D<br />
Includes connectors with no leads<br />
Use compatible low voltage controls<br />
only as referenced on page 2-22 & 2-23<br />
For wiring diagrams see page 2-13<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
2-15
T8<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 32W Lamps<br />
Mark 7 0-10V <strong>Electronic</strong> Dimming Ballast<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
F32T8, FBO31T8, F32T8/U6 (32W)<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Max/Min<br />
Ballast<br />
Factor<br />
Full Light Output<br />
THD %<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
1<br />
IZT-132-SC<br />
35/8 0.30-0.13<br />
55A<br />
CONTROLLABLE<br />
2<br />
3<br />
120-277<br />
IntelliVolt<br />
PS<br />
Mark 7<br />
0-10V<br />
IZT-2S32-SC<br />
IZT-3S32-SC<br />
70/14<br />
102/20<br />
1.00/0.03<br />
0.57-0.24<br />
10 0.86-0.37 50/10<br />
B<br />
56A<br />
57A<br />
MARK 70-10V<br />
4<br />
277<br />
120-277<br />
IntelliVolt<br />
VZT-4S32-HL<br />
IZT-4S32<br />
<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauge AWG 16-20.<br />
149/27<br />
116/25<br />
1.18/0.05<br />
0.88/0.03<br />
0.54<br />
0.98-0.42<br />
G<br />
D<br />
16A<br />
16A<br />
LINE<br />
CLASS 1 OR 2<br />
CIRCUIT<br />
10V, 0.5 mA<br />
BLACK<br />
WHITE<br />
VIOLET (+)<br />
{ GREY (-)<br />
BALLAST<br />
RED<br />
BLUE<br />
LINE<br />
CLASS 1 OR 2<br />
CIRCUIT<br />
10V, 0.5 mA<br />
BLACK<br />
WHITE<br />
VIOLET (+)<br />
{ GREY (-)<br />
BALLAST<br />
RED<br />
BLUE<br />
YELLOW<br />
BLACK<br />
LINE<br />
WHITE<br />
CLASS 1 OR 2 VIOLET (+)<br />
CIRCUIT { GREY (-)<br />
10V, 0.5 mA<br />
BALLAST<br />
LAMP<br />
RED<br />
BLUE/WHITE<br />
BLUE<br />
YELLOW<br />
LAMP<br />
LAMP<br />
LAMP<br />
LAMP<br />
LAMP<br />
Diag. 55A<br />
Diag. 56A<br />
Diag. 57A<br />
or<br />
RED<br />
YELLOW<br />
LAMP<br />
BALLAST<br />
BLUE/WHITE<br />
LAMP<br />
LAMP<br />
Diag. 16A<br />
LAMP<br />
ONLY USE RAPID-START SOCKETS<br />
Mark 7 0-10V Control Wiring (Grey and Violet)<br />
Wire Size Maximum Length (Ft.)<br />
AWG-16 800<br />
AWG-18 500<br />
AWG-20 320<br />
AWG-22 200<br />
AWG-24 120<br />
Refer to page 1-15 for information on remote/tandem<br />
wiring and lead length extension<br />
For ballast dimensions<br />
see page 2-13<br />
Use compatible low voltage controls<br />
only as referenced on page 2-22 & 2-23<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
2-16<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - ROVR<br />
Digital Addressable <strong>Ballasts</strong> for Linear Fluorescent, 4-Pin CFL, and T5/HO Lamps<br />
<strong>Advance</strong>'s ROVR series of digital addressable controllable fluorescent lamp ballasts are fully<br />
compatible with the DALI (Digital Addressable Lighting Interface) protocol, enabling two-way<br />
communications with individual lighting fixtures. ROVR ballasts offer an unprecedented degree<br />
of design flexibility, allowing users to set up any fluorescent lighting configuration they desire<br />
with numerous distinct dimming performance settings. Offering the ability to track and evaluate<br />
lighting systems as well as easily accommodate any moves or changes in the lighting configuration,<br />
ROVR ballasts fully support sustainable (green) design and are compatible with controls<br />
offered by numerous manufacturers.<br />
ROVR is ideal in applications such as conference rooms, educational facilities, auditoriums,<br />
hotels, and restaurants.<br />
DIMMING ROVR<br />
Features<br />
Full-range continuous dimming from 100%<br />
to 3% (down to 1% in T5/HO models)<br />
Operation directly from the DALI control<br />
signal<br />
Programmed Start ignition<br />
IntelliVolt® multiple-voltage technology<br />
enabling operation at any input voltage<br />
from 120 to 277 volts, 50/60Hz<br />
Color-coded, poke-in connectors on all<br />
CFL, T5/HO, and 4-Lamp T8 models<br />
Benefits<br />
Increases system flexibility and enhances visual comfort<br />
Supports sustainable design principles such as<br />
daylight harvesting<br />
Provides extended lamp life in frequent starting<br />
applications<br />
Enhances accuracy of ordering and reduces SKU<br />
requirements<br />
Enhances wiring accuracy and ease of<br />
assembly/installation<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 2-17
T4<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 13 - 70W Lamps<br />
ROVR Digital Addressable Ballast<br />
NORMAL POWER FACTOR<br />
SOUND RATED A<br />
CONTROLLABLE<br />
ROVR<br />
No. of<br />
Lamps<br />
CFQ13W/G24q - 13W CFL Quad Tube Lamp (PL-C13W/4P, F13DBX/4P, CF13DD/E)<br />
CFTR13W/GX24q - 13W CFL Triple Tube Lamp (F13TBX/4P, CF13DT/E)<br />
1<br />
2<br />
120-277<br />
IntelliVolt<br />
PS<br />
ROVR<br />
IDL-2S26-M5-BS<br />
IDL-2S26-M5-LD<br />
IDL-2S26-M5-BS<br />
IDL-2S26-M5-LD<br />
CFQ18W/G24q - 18W CFL Quad Tube Lamp (PL-C18W/4P, F18DBX/4P, CF18DD/E)<br />
CFTR18W/GX24q - 18W CFL Triple Tube Lamp (PL-T18W, F18TBX/4P, CF18DT/E)<br />
1<br />
2<br />
120-277<br />
IntelliVolt<br />
PS<br />
ROVR<br />
IDL-2S26-M5-BS<br />
IDL-2S26-M5-LD<br />
IDL-2S26-M5-BS<br />
IDL-2S26-M5-LD<br />
CFQ26W/G24q - 26W CFL Quad Tube Lamp (PL-C26W/4P, F26DBX/4P, CF26DD/E)<br />
CFTR26W/GX24q - 26W CFL Triple Tube Lamp (PL-T26W, F26TBX/4P, CF26DT/E)<br />
1<br />
2<br />
PS<br />
ROVR<br />
CFTR32W/GX24q - 32W CFL Triple Tube Lamp (PL-T32W, F32TBX/4P, CF32DT/E)<br />
1<br />
2<br />
CFTR42W/GX24q - 42W CFL Triple Tube Lamp (PL-T42W, F42TBX/4P, CF42DT/E)<br />
1<br />
2<br />
Input<br />
Volts<br />
120-277<br />
IntelliVolt<br />
120-277<br />
IntelliVolt<br />
120-277<br />
IntelliVolt<br />
Lamp<br />
Starting<br />
Method<br />
PS<br />
PS<br />
Ballast<br />
Family<br />
ROVR<br />
ROVR<br />
Catalog Number<br />
IDL-2S26-M5-BS<br />
IDL-2S26-M5-LD<br />
IDL-2S26-M5-BS<br />
IDL-2S26-M5-LD<br />
IDL-2S26-M5-BS<br />
IDL-2S26-M5-LD<br />
IDL-2T42-M5-BS<br />
IDL-2T42-M5-LD<br />
IDL-2S26-M5-BS<br />
IDL-2S26-M5-LD<br />
IDL-2T42-M5-BS<br />
IDL-2T42-M5-LD<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
CFTR57W/GX24q - 57W CFL Triple Tube Lamp (PL-T57W, F57QBX/4P, CF57DT/E)<br />
120-277<br />
IDL-2T42-M5-BS<br />
1 PS ROVR 65/16 1.00/0.03 10 0.55-0.24 50/10 Size 5 165<br />
IntelliVolt<br />
IDL-2T42-M5-LD<br />
CFTR70W/GX24q - 70W CFL Triple Tube Lamp (F70QBX/4P, CF70DT/E)<br />
120-277<br />
IDL-2T42-M5-BS<br />
1 PS ROVR 75/16 1.00/0.03 10 0.63-0.27 50/10 Size 5 165<br />
IntelliVolt<br />
IDL-2T42-M5-LD<br />
18/6<br />
32/19<br />
20/7<br />
41/11<br />
28/8<br />
49/13<br />
34/9<br />
75/19<br />
46/9<br />
98/18<br />
Max/Min<br />
Ballast<br />
Factor<br />
1.00/0.03 10<br />
1.00/0.03 10<br />
1.00/0.03 10<br />
1.00/0.03 10<br />
1.00/0.03 10<br />
Full Light Output<br />
THD %<br />
Line<br />
Current<br />
(Amps)<br />
0.14-0.07<br />
0.26-0.12<br />
0.15-0.08<br />
0.32-0.15<br />
0.22-0.10<br />
0.41-0.18<br />
0.28-0.13<br />
0.63-0.21<br />
0.38-0.17<br />
0.82-0.36<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
50/10 Size 5<br />
50/10 Size 5<br />
50/10 Size 5<br />
50/10 Size 5<br />
50/10 Size 5<br />
Wiring<br />
Dia.<br />
58B<br />
59B<br />
58B<br />
59B<br />
58B<br />
59B<br />
58B<br />
59B<br />
58B<br />
59B<br />
Burn in new lamps 100 hours at full light output before dimming.<br />
<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauges from AWG 16 - 20.<br />
ONLY USE 4-PIN RAPID-START SOCKETS<br />
For wiring diagrams<br />
see page 2-19<br />
Use compatible ROVR controls only<br />
as referenced on page 2-22 & 2-23<br />
For ballast dimensions<br />
see page 2-19<br />
Refer to page 1-15 for information on remote/tandem<br />
wiring and lead length extension<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
2-18<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 24W Lamps<br />
FT5<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ROVR Digital Addressable Ballast<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Max/Min<br />
Ballast<br />
Factor<br />
THD %<br />
FT24W/2G11 - 24/27WW Long Twin Tube Lamp (PL-L24W, F27BX/RS, FT24DL)<br />
Full Light Output<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
1<br />
2<br />
120-277<br />
IntelliVolt<br />
PS<br />
ROVR<br />
IDA-154*<br />
IDA-2S54<br />
Burn in new lamps 100 hours at full light output before dimming.<br />
<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauge AWG 16-20.<br />
*Available Q4 2006.<br />
ONLY USE RAPID-START SOCKETS<br />
Refer to page 1-15 for information on remote/tandem<br />
wiring and lead length extension<br />
59/13<br />
114/24<br />
0.50-0.22<br />
0.90/0.03 10<br />
50/10 D 165<br />
0.96-0.42<br />
3.00" (76.4) 2.00" (50.8)<br />
Size 5<br />
1.18" (30.0)<br />
M5<br />
4.20" (106.7)<br />
3.00" (76.4)<br />
4.55" (116.6)<br />
CONTROLLABLE ROVR<br />
1.18" (30.0)<br />
-BS<br />
4.20" (106.7)<br />
4.55" (116.6)<br />
-LD<br />
Fig. D<br />
Includes connectors with no leads<br />
DALI<br />
Class 1 or<br />
Class 2 Circuit<br />
{<br />
GREEN<br />
WHITE<br />
BLACK<br />
PURPLE<br />
PURPLE<br />
WIRING: (2) QUAD/TRIPLE LAMPS<br />
BLUE<br />
BALLAST YELLOW<br />
RED<br />
(1) QUAD/TRIPLE LAMP<br />
BLUE<br />
RED<br />
Green Terminal Must Be Grounded<br />
Diag. 165<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
Use compatible ROVR controls only<br />
as referenced on page 2-22 & 2-23<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
2-19
T5/HO<br />
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 54 - 55W Lamps<br />
ROVR Digital Addressable Ballast<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
F54T5/HO (54W)<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Max/Min<br />
Ballast<br />
Factor<br />
Full Light Output<br />
THD %<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
CONTROLLABLE<br />
1<br />
2<br />
120-277<br />
IntelliVolt<br />
FC12T5/HO (55W)<br />
PS<br />
ROVR<br />
IDA-154*<br />
IDA-2S54<br />
63/13<br />
125/24<br />
1.00/0.03<br />
10<br />
0.53-0.23<br />
1.05-0.45<br />
50/10<br />
D<br />
55B<br />
56B<br />
1<br />
2<br />
120-277<br />
IntelliVolt<br />
PS<br />
ROVR<br />
IDA-154*<br />
IDA-2S54<br />
59/13<br />
114/24<br />
0.90/0.03<br />
10<br />
0.50-0.22<br />
0.96-0.42<br />
50/10<br />
D<br />
55B<br />
56B<br />
ROVR<br />
<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauge AWG 16-20.<br />
*Available Q4 2006.<br />
ONLY USE RAPID-START SOCKETS<br />
Fig. D<br />
Includes connectors with no leads<br />
LINE<br />
DALI<br />
Class 1 or<br />
Class 2 Circuit<br />
{<br />
BLACK<br />
WHITE<br />
PURPLE<br />
PURPLE<br />
BALLAST<br />
RED<br />
BLUE<br />
LINE<br />
Class 1 or Class 2<br />
Circuit {<br />
BLACK<br />
WHITE<br />
PURPLE<br />
PURPLE<br />
BALLAST<br />
LAMP<br />
RED<br />
BLUE/WHITE<br />
BLUE<br />
YELLOW<br />
LAMP<br />
LAMP<br />
LAMP<br />
Diag. 55B<br />
Diag. 56B<br />
Diag. 57B<br />
DALI<br />
Class 1 or<br />
Class 2<br />
Circuit<br />
{<br />
PURPLE<br />
PURPLE<br />
GREEN<br />
BLACK<br />
BALLAST<br />
RED<br />
YELLOW<br />
BLUE/WHITE<br />
LAMP<br />
LAMP<br />
LAMP<br />
LINE<br />
WHITE<br />
BROWN<br />
BLUE<br />
LAMP<br />
Diag. 167<br />
Refer to page 1-15 for information on remote/tandem<br />
wiring and lead length extension<br />
Use compatible ROVR controls only<br />
as referenced on page 2-22 & 2-23<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
2-20<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
For 17 - 32W Lamps<br />
T8<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ROVR Digital Addressable Ballast<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Max/Min<br />
Ballast<br />
Factor<br />
Full Light Output<br />
THD %<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
F17T8, FBO16T8 (17W)<br />
1<br />
2<br />
F25T8, FBO24T8 (25W)<br />
1<br />
2<br />
3<br />
120-277<br />
IntelliVolt<br />
120-277<br />
IntelliVolt<br />
PS<br />
PS<br />
ROVR<br />
ROVR<br />
IDA-132-SC*<br />
IDA-2S32-SC*<br />
IDA-132-SC*<br />
IDA-2S32-SC*<br />
IDA-3S32-G<br />
20/7<br />
36/11<br />
28/8<br />
52/12<br />
79/19<br />
1.00/0.03<br />
1.00/0.03<br />
10<br />
10<br />
0.16-0.07<br />
0.30-0.13<br />
0.24-0.11<br />
0.43-0.19<br />
0.65-0.28<br />
50/10<br />
50/10<br />
B<br />
B<br />
G<br />
55B<br />
56B<br />
55B<br />
56B<br />
57B<br />
CONTROLLABLE ROVR<br />
4<br />
IDA-4S32<br />
96/22<br />
0.88/0.03<br />
0.77-0.35<br />
D<br />
167<br />
F32T8, FBO31T8, F32T8/U6 (32W)<br />
1<br />
IDA-132-SC*<br />
35/8<br />
0.30-0.13<br />
55B<br />
B<br />
2<br />
3<br />
120-277<br />
IntelliVolt<br />
PS<br />
ROVR<br />
IDA-2S32-SC*<br />
IDA-3S32-G<br />
70/14<br />
102/20<br />
1.00/0.03<br />
0.57-0.24<br />
10 50/10<br />
0.86-0.37<br />
G<br />
56B<br />
57B<br />
4<br />
IDA-4S32<br />
116/25<br />
0.88/0.03<br />
0.98-0.42<br />
D<br />
167<br />
<strong>Ballasts</strong> utilizing poke-in connectors can accept wire gauge AWG 16-20.<br />
*Available Q4 2006.<br />
ONLY USE RAPID-START SOCKETS<br />
Fig. G<br />
1.18"<br />
8.90"<br />
9.5"<br />
1.7"<br />
Fig. B<br />
Refer to page 1-15 for information on remote/tandem<br />
wiring and lead length extension<br />
Fig. D<br />
Includes connectors with no leads<br />
For wiring diagrams<br />
see page 2-20<br />
Use compatible ROVR controls only<br />
as referenced on page 2-22 & 2-23<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
2-21
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Control Manufacturers for <strong>Advance</strong> ® Mark 7 0-10V <strong>Electronic</strong> Dimming<br />
<strong>Ballasts</strong> and Mark 10 Powerline <strong>Electronic</strong> Dimming <strong>Ballasts</strong><br />
ROVR Digital Addressable <strong>Ballasts</strong><br />
MANUFACTURER PHONE MARK 7 0-10V 4-Wire MARK 10 Powerline 2-Wire Line Voltage ROVR<br />
Alerton Technologies Inc. 425-869-8400 TX16160 N/A<br />
ALM Systems Inc. 847-860-0959 SS-120 OR SS-277 ABIUF Dimming Module<br />
AMX Corporation 800-222-0193 Radia (RDM-HDC) & RDM-DC RDD & RDM Series<br />
Series<br />
Automated Logic Corp. 770-429-3000 S Series & M Series S Series and M Series<br />
CONTROLLABLE<br />
COMPATIBLE<br />
CONTROL<br />
Avab America 415-505-5515 PWR Series PWR Series<br />
Blackbird 800-421-3562 2BMO-FLST-AB-IR BBMO-MX-AB-IR<br />
Colortran, Inc. 503-682-1941 Digital Ballast Controller ENR, I Series, I Series E, and<br />
I Series Quad<br />
Crestron <strong>Electronic</strong>s 201-767-3400 CresLite Lighting System CresLite Lighting System<br />
Cutler-Hammer 803-481-6870 POW-R-Command System N/A<br />
Digital Lighting Systems 305-264-8391 Protocol Protocol<br />
Douglas Lighting Controls 604-873-2797 WPC-5700, WPN-5721, MC6000, MC6000, Dilor ALC3<br />
Dilor ALC3, Lightpoint WBC-2512<br />
Echo Controls 866-ECHODIM Echo-Dim<br />
<strong>Electronic</strong> Theatre Controls 608-831-4116 SENSOR or UNISON SENSOR or UNISON<br />
<strong>Electronic</strong>s Diversified, Inc. 503-645-5533 Prolite Dimming System, Versa- Prolite Dimming System, Versa-Pak<br />
Pak System, Mark 10 System Rack System, Mark 10 System Rack<br />
Entertainment Technologies 800-223-9477 Tap Glide, IPS, Capio Plus, Oasis Intelli Set Plus, Tap Glide, U-Set, IPS,<br />
Honeywell, Inc. 800-345-6770 EL7315A1019 or EL7315A1009 N/A<br />
Capio Plus<br />
Hubbell Building Automation 888-698-3242 DLC-7, OMNI, Light Owl, OMNI, Light Owl, Light Hawk, LP-2<br />
Light Hawk, LP-2<br />
Hunt Dimming 970-484-9048 PS, FD and SSD Simplicity Series PS, SC, FD and SSD Simplicity Series PS Series<br />
Intelligent Lighting Controls 800-922-8004 Light Master<br />
Johnson Controls 414-274-4000 Application Specific N/A<br />
Leax Controls 970-927-4845 Consult Factory Consult Factory<br />
Lehigh <strong>Electric</strong> Products Co. 610-395-3386 Sentry, Solitaire, DX2, Solitaire, DX2,<br />
Sunburst, ALX and DX with<br />
Sunburst, ALX and DX with<br />
DCFL Interface<br />
ACFL Interface<br />
Leviton Lighting Control Div. 800-824-3005 Centura, Wallbox: IllumaTech, Wallbox Dimmers: Monet, Renoir, Mural, CD100<br />
PE300-D (Slave Pack). TouchPoint, IllumaTech, SureSlide. CD250<br />
Occupancy Sensors: Multi-Tech, Occupancy Sensors: Multi-Tech, Wide<br />
Wide View, High Bay, Ultrasonic. View, High Bay, Ultrasonic, PIR.<br />
Systems: a-2000, MDS, D3200 Systems: a-2000, I series e, MDS,<br />
Power Master Station, Dimensions D3200<br />
The listed manufacturers have indicated that they manufacture products that properly control the <strong>Advance</strong> Mark 7 0-10V electronic dimming ballasts,<br />
<strong>Advance</strong> Mark 10 Powerline electronic dimming ballasts, or ROVR digital addressable ballasts. <strong>Advance</strong> Transformer provides this list as a service to our<br />
customers and control manufacturers. <strong>Advance</strong> does not support or recommend one manufacturer over another. Please refer to each manufacturer's catalog<br />
for a complete product description and performance specifications.<br />
2-22<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH FREQUENCY ELECTRONIC BALLASTS<br />
Control Manufacturers for <strong>Advance</strong> ® Mark 7 0-10V <strong>Electronic</strong> Dimming<br />
<strong>Ballasts</strong> and Mark 10 Powerline <strong>Electronic</strong> Dimming <strong>Ballasts</strong><br />
ROVR Digital Addressable <strong>Ballasts</strong><br />
MANUFACTURER PHONE MARK 7 0-10V 4-Wire MARK 10 Powerline 2-Wire Line Voltage ROVR<br />
Lighting Control and Design 323-226-0000 GR4000 GR4000<br />
Lightolier Controls 800-526-2731 Sunrise Preset, Momentum Preset, MultiSet Pro, Sunrise Preset,<br />
Vega Slider, Lytemode module Momentum Preset, Onset, Vega Slider,<br />
Lytemode module<br />
Lithonia Controls 770-987-4200 SLD, Equinox, Digital Equinox, DSD, SLD, Synergy, Sequel, Litronic<br />
Synergy, Sequel, Litronic<br />
Lutron 800-523-9466 See www.lutron.com/advance See www.lutron.com/advance<br />
Marlin Controls 800-788-5750 EFD, Stellar Starbright Dimming System Stellar<br />
NexLight 218-828-3700 WR, WRT, WTV Series Switches WR, WRT, WTV Series Switches and<br />
and Components, LS III<br />
Components, LS III<br />
Novar Controls 330-670-1010 FDI (Fluorescent Dimming Interface) N/A<br />
Novitas 310-568-9600 Wide array of ceiling sensors, wall N/A<br />
sensors, and photocells<br />
Payne Sparkman Mfg., Inc. 812-944-4893 LTRD/4W Series LTRD/2W Series<br />
CONTROLLABLE COMPATIBLE<br />
CONTROL<br />
PDM <strong>Electric</strong>al Products 514-342-6581 WPC-5700, WPN-5721, MC6000, MC6000, Dilor ALC3<br />
Dilor ALC3, Lightpoint WBC-2512<br />
PLC Multipoint 425-353-7552 EDSAB and RCD Dial EDSPR<br />
Sensor Switch, Inc. 800-727-7483 CM-ALC, CM-9, CM-PDT, CM-PC, N/A<br />
WV-16, WV-PDT<br />
Starfield Controls 303-427-1661 TaskRite TaskRite TaskRite<br />
DALInet<br />
Sterner Controls 320-543-3595 BPM-ELVFL-0-10 or ARA series BPM-EHVFL-2W or ARA series<br />
Strand Lighting 714-230-8200 <strong>Electronic</strong> Fluorescent Ballast DE90 & CD80S Dimming Systems<br />
Controller (120/277V)<br />
Touch-Plate Lighting 219-426-1565 CPD-8000D & MCP Series MCD-4000 & CPD-4000<br />
TRIATEK Lighting Inc. 800-241-9173 Digi-Touch NA<br />
Vantage Lighting Control 801-229-2800 SD4008-120, SD9008-277, LVOS SD4008-120, SD9008-277, Scenepoint,<br />
Radiolink Scenepoint, Powerstation 110V,<br />
Powerstation 277V<br />
Vara-Light/Dimatronics/HUB 815-455-4400 PFC-Analog and PGS-M-Digital DCM with FL-60 (digital) or<br />
M36 (analog)<br />
Watt Stopper, Inc. 408-988-5331 LS, IRT, W, WT, CI, CX, DT, IRC, WD 170, WD 180, WD270, and WD 280 ezDALI<br />
LIGHTSAVER<br />
The listed manufacturers have indicated that they manufacture products that properly control the <strong>Advance</strong> Mark 7 0-10V electronic dimming ballasts,<br />
<strong>Advance</strong> Mark 10 Powerline electronic dimming ballasts, or ROVR digital addressable ballasts. <strong>Advance</strong> Transformer provides this list as a service to our<br />
customers and control manufacturers. <strong>Advance</strong> does not support or recommend one manufacturer over another. Please refer to each manufacturer's catalog<br />
for a complete product description and performance specifications.<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 2-23
ELECTROMAGNETIC BALLASTS<br />
ELECTROMAGNETIC<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
ELECTROMAGNETIC BALLASTS<br />
Case - rugged steel ballast case Thermal Protector - exclusive ADVAN-guard ®<br />
automatic reclosing protective device affords<br />
Class P thermal protection on all ADVANCE fluorescent<br />
lamp ballasts ordered with”TP” suffix.<br />
Compound - special thermal-pliable compound<br />
containing a high percentage of silica<br />
ensures rapid heat conductivity. Dampens<br />
vibration and ballast hum. Careful filling<br />
excludes moisture, increases insulation<br />
resistance.<br />
Dry Capacitor - is used for power factor correction<br />
and phase displacement, capacitors<br />
(used only on high power factor ballast) are<br />
of highest quality. Rigid inspection and tests<br />
assure uninterrupted, dependable service.<br />
ELECTROMAGNETIC<br />
Laminations - laminations are constructed<br />
of high-grade steel, annealed and treated to<br />
assure lowest wattage losses. They are precision<br />
stamped with carbide steel dies for<br />
positive, tight stacking to provide consistent<br />
electrical characteristics.<br />
Coils - highest quality annealed wire is<br />
used in the precision winding of all coils.<br />
Uniform, firmly wound coils assure consistent<br />
operating characteristics.<br />
Complete core & coil assembly is vacuum<br />
impregnated with an exclusive <strong>Advance</strong><br />
asphalt-wax impregnant.<br />
Lead Wire - PVC covered solid lead wire is<br />
firmly anchored to the coils to facilitate positive<br />
and permanent connections.<br />
Supply Voltage and Frequency<br />
Each ballast is designed to operate at the nominal<br />
voltage shown on the ADVANCE label. Abnormal deviation<br />
from these values will result in damage to either<br />
the ballast or lamp or both. It is therefore necessary<br />
that the voltage applied to ballasts be maintained within<br />
the respective limits shown in the adjoining table.<br />
A ballast subjected to higher than nominal voltages<br />
will operate at increased temperatures. This will result<br />
in reduced ballast life. Low voltage can cause premature<br />
lamp failures as well as unreliable lamp starting.<br />
All ballasts are designed for single frequency operation.<br />
Therefore, best results will be obtained when that<br />
ballast is used on the frequency shown on the ballast<br />
label. Frequency limitations are as follows:<br />
Nominal Frequency Limits<br />
60HZ 57.5 to 62.5<br />
50HZ 47.5 to 52.5<br />
Prefix<br />
Code<br />
Letters<br />
Normal<br />
Voltage<br />
Applied Voltage<br />
Limits<br />
Color Label<br />
Identification<br />
H 120 112-127 YELLOW<br />
R 120 112-127 YELLOW<br />
L 120 112-127 YELLOW<br />
S 120 112-127 YELLOW<br />
X 220 210-230 GREEN<br />
M 220/250 210-230 / 235-260 —<br />
Y 240 225-250 ORANGE<br />
V 277 255-290 RED<br />
G 347 322-365 GRAY<br />
3-2<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
ELECTROMAGNETIC BALLASTS<br />
Ballast Date Codes<br />
<strong>Advance</strong> electromagnetic<br />
fluorescent lamp ballasts are<br />
date stamped on the ballast<br />
cover to designate month<br />
and year of manufacture. The<br />
month is indicated first, followed<br />
by the year. In the<br />
example shown (1-00), the<br />
manufacturing date is<br />
January, 2000. See page 8-ii for warranty information.<br />
Certifications<br />
Indicates ballast is listed with Underwriters<br />
Laboratories, Inc. and complies with UL935 Standard<br />
for Fluorescent -Lamp <strong>Ballasts</strong> (File No. E14927).<br />
U.L. RECOGNIZED<br />
Indicates ballast is component recognized with<br />
UL. and complies with UL935 Standard for<br />
Fluorescent -Lamp <strong>Ballasts</strong> (File No. E14927).<br />
Visit www.ul.com to find a current listing of<br />
<strong>Advance</strong> ballasts under File No. E14927.<br />
Indicates ballast is certified by Cnadian Standards<br />
Association and complies with CAN/CSA-22.2 No.<br />
74-92 for Fluorescent-Lamp <strong>Ballasts</strong> (File No.<br />
LR7310).<br />
Indicates ballast complies with U.S. Energy<br />
Standards.<br />
Indicates ballast complies with Canadian Energy<br />
Standards.<br />
<strong>Advance</strong> fluorescent ballasts are designed<br />
and manufactured in accordance with the<br />
American National Standards Institute<br />
standard for fluorescent ballasts, ANSI C82.1.<br />
Class P <strong>Ballasts</strong> — <strong>Section</strong> 410-73(e) of the National<br />
<strong>Electric</strong>al Code (NEC) requires that all indoor fluorescent fixtures<br />
shall incorporate ballast protection. Those fixtures employing a<br />
simple reactive type ballast are exempted.<br />
The protector is located within the ballast case to prevent<br />
physical damage and tampering.<br />
<strong>Advance</strong> electromagnetic ballasts ordered with ADVAN-guard ®<br />
Class P ballast protection (TP suffix) are equipped with a thermally<br />
actuated automatic reclosing protective device. This revolutionary<br />
development was originally designed and introduced by <strong>Advance</strong>,<br />
and today this Class P device is a requirement of the National<br />
<strong>Electric</strong>al Code in all indoor lighting installations.<br />
Safety<br />
The National <strong>Electric</strong>al Code requires grounding of fluorescent<br />
fixtures. The fluorescent ballast case must be grounded either to<br />
the fluorescent fixture or, if remote mounted, by other means<br />
such as a wire from the ballast case to ground. Without proper<br />
fixture and ballast grounding, a shock hazard may exist due to<br />
the fluorescent fixture becoming energized by an internal ballast<br />
failure to case. Also, all ballasts have normal leakage current.<br />
When the ballast is properly grounded, the leakage current does<br />
not constitute a hazard.<br />
Starting<br />
The metal of a fluorescent fixture is a starting aid when properly<br />
grounded. T12 Fluorescent lamps rated at 40 watts or less<br />
used for rapid or trigger start operation must be mounted within<br />
1/2” of a grounded metal surface. T8 Lamps must be mounted<br />
within 3/4” of a grounded metal surface. All other lamps must<br />
be mounted within 1” of a grounded metal surface.<br />
An important additional factor for proper lamps starting is<br />
polarity. The white ballast lead must be connected to the ground<br />
of the power supply (neutral) and the black lead to the hot line<br />
wire. A reversal of polarity may result in lamp damage or improper<br />
lamp starting.<br />
Cold Weather Operation<br />
Lumen ratings of fluorescent lamps apply for operation in still<br />
air at a temperature of 77°F. While many fluorescent lamps and<br />
fluorescent lamp ballasts are designed to give their best performance<br />
at 77°F, they will provide reasonably good light output<br />
down to 50°F. Further decreases in ambient temperature will<br />
result in decreased light output.<br />
Variables such as humidity, line voltage, fixture design and<br />
variations within the particular design of the lamp and the fluorescent<br />
lamp ballast play an important part in determining the<br />
low temperature starting limit.<br />
These are the two considerations for low temperature application:<br />
1. Starting of the lamps<br />
Low temperatures change the electrical starting characteristics<br />
of a fluorescent lamp. As the fluorescent lamp becomes<br />
colder, it becomes more difficult to start. Therefore, a fluorescent<br />
ballast must have a higher starting voltage; thus, follow<br />
the temperature recommendations shown in the tables.<br />
<strong>Ballasts</strong> designed for low temperature use ensure reliable<br />
starting only and not the light output.<br />
2. Operating the lamps<br />
The light output of any fluorescent lamp depends on the<br />
mercury vapor pressure within the lamp. Maximum light<br />
output for most fluorescent lamps occurs when the bulb<br />
temperature is about 100°F. As bulb wall temperature goes<br />
above 100°F the mercury vapor pressure within the tube<br />
increases and the light output decreases.<br />
Interestingly enough, at lower bulb-wall temperatures,<br />
the mercury condenses on the tube, pressure drops and the<br />
light output again decreases. This is inherent in all fluorescent<br />
lamps. In order to prevent reduction in light output at<br />
low temperatures the lamp should be enclosed so it has a<br />
chance to overcome the low bulb-wall temperature by the<br />
heat generated by the lamp.<br />
In general, outdoor lighting installations have tended toward<br />
800 and 1500mA lamps since the additional heat generated by<br />
these lamps will provide better illumination in cold weather than<br />
can be obtained with 430mA lamps. The 430mA lamps are not recommended<br />
by the lamp manufacturer for starting conditions<br />
below 0°F. Above this temperature,shielding is required to a<br />
greater degree than with the more heavily loaded lamps. Special<br />
low temperature lamps, which may be purchased with shields, are<br />
available for 1500mA operation.<br />
ELECTROMAGNETIC<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 3-3
ELECTROMAGNETIC BALLASTS<br />
Ballast Sound<br />
The slight hum present in fluorescent lighting installations<br />
originates from the inherent magnetic action in the core & coil<br />
assembly of the ballasts. This hum may be amplified by the<br />
method of mounting the ballast in the fixture...the fixture<br />
design...and, more often than not, this hum is amplified by the<br />
resonant qualities of the ceiling, walls, floors and furniture. In<br />
planning a lighting installation, careful consideration must be<br />
given to the selection of the fluorescent lamp ballast, the lighting<br />
fixture and room components. These precautions will ensure the<br />
quietest installation possible.<br />
The choice of fluorescent lamp ballast should be made on the<br />
basis of selecting the one rated quietest for a specific location or<br />
interior as some ballast have a more discernable hum due to<br />
basic construction features and electrical ratings.<br />
It is therefore essential that a ballast which is placed in an<br />
enclosure be suitably ventilated. Where more than one ballast is<br />
installed in an enclosure, the ballast should be positioned far<br />
enough apart to provide adequate heat dissipation.<br />
To assist in limiting the temperature rise of ballasts, the following<br />
procedures are recommended:<br />
• Mount ballast with maximum number of sides in direct<br />
contact with the metal channel of fixture. Radiators are<br />
an excellent way of dissipating heat.<br />
• Provide fixture ventilation.<br />
• Paint the unpainted fixture channels with a non-metallic<br />
finish to increase radiation.<br />
SOUND RATINGS<br />
• Place ballast in a cooler location outside the fixture.<br />
ELECTROMAGNETIC<br />
For any Installation in:<br />
TV or Radio Station,<br />
Library, Reception or<br />
Reading Room, Church,<br />
School Study Hall<br />
Average Ambient<br />
Noise Level<br />
Of Interior<br />
20-24<br />
DECIBELS<br />
Residence, Quiet Office, 25-30<br />
Night School Classroom DECIBELS<br />
General Office Area,<br />
Commercial Building,<br />
Storeroom<br />
31-36<br />
DECIBELS<br />
Sound<br />
Level<br />
Rating*<br />
A<br />
B<br />
C<br />
• Place fixture to attain maximum dissipation of heat by<br />
conduction, convection or radiation.<br />
BALLAST TYPE<br />
Magnetic = Standard electromagnetic core and coil construction<br />
continues to provide reliable service and economy over a wide<br />
variety of lighting system applications. Operates lamps at 60 Hz.<br />
Mark III = Energy-saving electromagnetic ballast designed to<br />
provide 10% energy savings over corresponding standard magnetic<br />
units while maintaining equivalent full light output.<br />
Operates lamps at 60 Hz.<br />
E-PAK = Energy-saving electromagnetic ballast specifically optimized<br />
for energy saving lamps to provide 17% energy savings<br />
over corresponding standard magnetic units while maintaining<br />
equivalent light output. Operates lamps at 60 Hz.<br />
Manufacturing Facility,<br />
Retail Store,<br />
Noisy Office<br />
37-42<br />
DECIBELS<br />
D<br />
*These sound ratings are based on measurements of Average Ambient<br />
noise levels during conditions of normal occupancy. Audible ballast hum<br />
may appear amplified during exceptionally quiet periods and at times when<br />
area is unoccupied.<br />
Temperature and Ventilation<br />
Underwriters’ Laboratories, Inc. stipulates that the temperature<br />
limitation of a fluorescent lamp ballast using Class A insulation<br />
at normal operation should have a maximum ballast coil<br />
temperature of 105°C (221°F) and maximum ballast case temperature<br />
of 90°C (194°F) at its hottest spot. Ballast life will be<br />
reduced if it is operated at a temperature above these limits.<br />
A fluorescent lamp ballast, like other electrical equipment,<br />
generates heat during normal operation. If not maintained within<br />
prescribed limits, this heat will become the primary cause of<br />
reduced ballast life. Heat generated in the conventional ballast is<br />
transferred to the case through a silica compound which totally<br />
surrounds the internal components and is then dissipated to the<br />
surrounding air or mounting surface by conduction, convection<br />
or radiation.<br />
3-4<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
ELECTROMAGNETIC BALLASTS<br />
Straight<br />
Rapid Start Lamps<br />
T4 T8 T5<br />
and<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim.<br />
Wiring<br />
Dia.<br />
F17T8 (265mA)<br />
1 17 50<br />
2 17 50<br />
120 R-1P817-TP ✓ ✓ 0.21 24 1.01
T5HO T8<br />
CENTIUM ®<br />
ELECTROMAGNETIC BALLASTS<br />
U-Shaped<br />
Rapid Start Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim.<br />
Wiring<br />
Dia.<br />
ELECTROMAGNETIC<br />
RAPID START<br />
FBO16T8 (265mA)<br />
1 16 50<br />
120 R-1P817-TP ✓ ✓ 0.20 23 0.98
ELECTROMAGNETIC BALLASTS<br />
Straight<br />
Rapid Start Lamps<br />
T4 T10 T5<br />
and<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim.<br />
Wiring<br />
Dia.<br />
F40T10 (420mA)<br />
120 R-140-TP Mark III R ✓ ✓ ✓ ✓ 0.46 53 0.95
T12<br />
ELECTROMAGNETIC BALLASTS<br />
Straight<br />
Rapid Start Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTROMAGNETIC<br />
RAPID START<br />
Lamp Data Min.<br />
Starting<br />
Number Watts Temp.<br />
(F)<br />
F25T12 (455mA)<br />
1 25 60<br />
2 25 60<br />
F30T12 (430mA)<br />
1 30 50<br />
2 30 50<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
120 HM-1P30-TP ✓ ✓ 0.34 40 0.91
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
ELECTROMAGNETIC BALLASTS<br />
Straight<br />
Rapid Start Lamps<br />
T12<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
Lamp Data Min.<br />
Starting<br />
Number Watts Temp.<br />
(F)<br />
F34T12 (460mA)<br />
● Sound Rated B<br />
✪ For Residential Use Only<br />
LINE<br />
BLUE<br />
BLUE<br />
WHITE<br />
BLK/WHT<br />
LAMP<br />
BALLAST<br />
Diag. 20<br />
Input<br />
Volts<br />
❉ Normal Power Factor<br />
R For Replacement Use Only<br />
RED<br />
RED<br />
Catalog<br />
Number<br />
Certifications<br />
DIMENSIONS<br />
Designation<br />
Length (L)<br />
(inches)<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
120 R-140-TP Mark III R ✓ ✓ ✓ ✓ 0.38 43 0.88
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
T12<br />
ELECTROMAGNETIC BALLASTS<br />
Straight<br />
Rapid Start Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
ELECTROMAGNETIC<br />
RAPID START<br />
Lamp Data<br />
Number<br />
Watts<br />
F40T12 (430mA)<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
1 40 50<br />
2 40 50<br />
Input<br />
Volts<br />
120<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
R-140-TP Mark III R ✓ ✓ ✓ ✓ 0.43 50 0.95
ELECTROMAGNETIC BALLASTS<br />
U-Shaped<br />
Rapid Start Lamps<br />
T12<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
F34T12/U (460mA)<br />
1 34 60<br />
2 34 60<br />
F40T12/U (430mA)<br />
1 40 50<br />
2 40 50<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
120 R-1U40-T0P Mark III R ✓ ✓ ✓ 0.39 44 0.93
T12<br />
Dimming<br />
ELECTROMAGNETIC BALLASTS<br />
Straight & U-Shaped<br />
Rapid Start Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
F40T12 (430mA)<br />
F40T12/U (430mA)<br />
1<br />
2<br />
40<br />
40<br />
50<br />
50<br />
120<br />
120<br />
Data listed is for full light output<br />
Line Current Controlled by Control Setting<br />
Dimming Range-100%—5%<br />
All Require Circuit Interrupting Lampholders<br />
Note: Will NOT Operate 34W Energy Saver Lamps<br />
DIM-140-H-TP ✓ ✓ 0.52 58 1.00
ELECTROMAGNETIC BALLASTS<br />
High Output<br />
Rapid Start Lamps<br />
T12/HO<br />
HIGH POWER FACTOR<br />
SOUND RATED C<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
F24T12/HO (800mA)<br />
1 35 -20<br />
120 RS-110-TP ● ✓ ✓ 0.58 63 0.93
T12/HO<br />
ELECTROMAGNETIC BALLASTS<br />
High Output<br />
Rapid Start Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED C<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim.<br />
Wiring<br />
Dia.<br />
F42T12/HO (800mA)<br />
1 55 -20<br />
2 55 -20<br />
120 RS-110-TP ● ✓ ✓ 0.69 80 0.96
ELECTROMAGNETIC BALLASTS<br />
High Output<br />
Rapid Start Lamps<br />
T12/HO<br />
HIGH POWER FACTOR<br />
SOUND RATED C<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
F60T12/HO (800mA)<br />
120<br />
RS-110-TP ● ✓ ✓ 0.83 97 0.93
T12/HO<br />
ELECTROMAGNETIC BALLASTS<br />
High Output<br />
Rapid Start Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED C<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
ELECTROMAGNETIC<br />
HIGH OUTPUT<br />
F72T12/HO (800mA)<br />
120<br />
RC-2S85-TP ✓ ✓ 0.98 100 0.82
ELECTROMAGNETIC BALLASTS<br />
High Output<br />
Rapid Start Lamps<br />
T12/HO<br />
HIGH POWER FACTOR<br />
SOUND RATED C<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
F96T12/HO Energy Saver (840mA)<br />
120 RS-110-TP ● ✓ ✓ 1.00 121 0.94
T10 and T12/VHO<br />
ELECTROMAGNETIC BALLASTS<br />
Very High Output<br />
VHO & Powergroove Rapid Start Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED D<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
ELECTROMAGNETIC<br />
VERY HIGH OUTPUT<br />
F48T10/VHO (1500mA)<br />
F48T12/VHO (1500mA)<br />
F48PG17/VHO (1500mA)<br />
1<br />
2<br />
116<br />
116<br />
-20<br />
-20<br />
120<br />
120<br />
RC-2S102-TP<br />
RC-2S102-TP<br />
✓<br />
✓<br />
✓<br />
✓<br />
1.70<br />
2.20<br />
130<br />
230<br />
0.87<br />
0.89<br />
ELECTROMAGNETIC BALLASTS<br />
Very High Output<br />
VHO & Powergroove Rapid Start Lamps<br />
T10 and T12/VHO<br />
HIGH POWER FACTOR<br />
SOUND RATED D<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
F96T12/VHO Energy Saver (1580mA)<br />
F96PG17/VHO Energy Saver (1580mA)<br />
1 185 60<br />
120 RC-2S102-TP ✓ ✓ 2.00 198 0.87
T6,T8,T12<br />
ELECTROMAGNETIC BALLASTS<br />
Slimline & Instant Start<br />
Instant Start Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED C<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
F42T6 (200mA)<br />
1 25 0 120 SM-151-S-TP ✓ ✓ 0.42 45 1.00
ELECTROMAGNETIC BALLASTS<br />
Slimline & Instant Start<br />
Instant Start Lamps<br />
T12 and T17<br />
HIGH POWER FACTOR<br />
SOUND RATED C<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
F24T12 (425mA)<br />
1 20 0 120 SM-140-S-TP ✓ ✓ 0.45 45 0.93
T12 SLIMLINE<br />
ELECTROMAGNETIC BALLASTS<br />
Slimline<br />
Instant Start Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED C<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
F60T12 (425mA)<br />
1<br />
2<br />
50<br />
50<br />
0<br />
0<br />
120 RSM-175-S-TP ✓ ✓ 0.74 73 0.93
ELECTROMAGNETIC BALLASTS<br />
Slimline<br />
Instant Start Lamps<br />
T12 SLIMLINE<br />
HIGH POWER FACTOR<br />
SOUND RATED C<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
F96T12 Energy Saver (440mA)<br />
1 60 60<br />
120 RSM-175-S-TP ✓ ✓ 0.68 74 0.88
T5<br />
ELECTROMAGNETIC BALLASTS<br />
Preheat Lamps<br />
Preheat <strong>Ballasts</strong> (Starter Required)<br />
✩<br />
CLASS B INSULATION NORMAL POWER FACTOR SOUND RATED A<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
ELECTROMAGNETIC<br />
PREHEAT<br />
F4T5<br />
1<br />
F6T5<br />
1<br />
F8T5<br />
4<br />
6<br />
50<br />
50<br />
120<br />
120<br />
LPL-5-9 ◆✖❏<br />
LPL-5-9 ◆✖❏<br />
✓<br />
✓<br />
✓<br />
✓<br />
0.19<br />
0.17<br />
9<br />
9<br />
1.01<br />
1.02<br />
ELECTROMAGNETIC BALLASTS<br />
Preheat Lamps<br />
Preheat <strong>Ballasts</strong> (Starter Required)<br />
✩<br />
T8<br />
CLASS B INSULATION NORMAL POWER FACTOR SOUND RATED A<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
F13T8<br />
1 13 50 120 LO-13-22 ◆✖❏ ✓ ✓ 0.34 17 0.91
T12<br />
ELECTROMAGNETIC BALLASTS<br />
Preheat Lamps<br />
Preheat <strong>Ballasts</strong> (Starter Required)<br />
✩<br />
CLASS B INSULATION NORMAL POWER FACTOR SOUND RATED A<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
ELECTROMAGNETIC<br />
PREHEAT<br />
F14T12<br />
1<br />
F15T12<br />
14 50 120<br />
LO-13-22 ✖◆❏ ✓ ✓ 0.34 18 0.92
ELECTROMAGNETIC BALLASTS<br />
Preheat Lamps<br />
Trigger Start <strong>Ballasts</strong><br />
T5 and T8<br />
NORMAL POWER FACTOR<br />
SOUND RATED A<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
F4T5 4W<br />
F6T5 6W<br />
F8T5 8W<br />
1 8 50<br />
120 LQ-106F-TP ✓ 0.34 14 0.86
T12<br />
ELECTROMAGNETIC BALLASTS<br />
Preheat Lamps<br />
Trigger Start <strong>Ballasts</strong><br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
ELECTROMAGNETIC<br />
PREHEAT<br />
❖<br />
❉<br />
F14T12<br />
1 14<br />
50 RLQ-120-TP ❖❉ ✓ ✓ 0.58 28 0.92
T12<br />
ELECTROMAGNETIC BALLASTS<br />
Preheat Lamps<br />
Trigger Start <strong>Ballasts</strong><br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
ELECTROMAGNETIC<br />
PREHEAT<br />
❖<br />
❉<br />
F14T12<br />
1 14<br />
50 RLQ-120-TP ❖❉ ✓ ✓ 0.58 28 0.92
T9<br />
ELECTROMAGNETIC BALLASTS<br />
Circline Lamps<br />
Rapid Start <strong>Ballasts</strong><br />
NORMAL POWER FACTOR<br />
SOUND RATED A<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
ELECTROMAGNETIC<br />
CIRCLINE<br />
FC6T9 (20W Circline)<br />
1 20 50 120 RLQS-122-TP-W ✓ ✓ 0.56 24 0.76
ELECTROMAGNETIC BALLASTS<br />
2-Pin Compact Lamps<br />
Preheat <strong>Ballasts</strong><br />
T4<br />
CLASS B INSULATION NORMAL POWER FACTOR SOUND RATED A<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line Current (Amps)<br />
Operating Starting<br />
Open<br />
Circuit<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
% Dim. Wiring<br />
Dia.<br />
CFT5W/G23 - 5W Twin Tube Lamp (PL-S5W, F5BX, CF5DS)<br />
1 5 0 120 LPL-5-9-TP ◆ ❏ ✓ ✓ 0.19 0.19 — 9 1.06
T4 and T5<br />
ELECTROMAGNETIC BALLASTS<br />
2-Pin Compact & 4-Pin Long Twin Tube Lamps<br />
Preheat <strong>Ballasts</strong><br />
CLASS B INSULATION NORMAL POWER FACTOR SOUND RATED A<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line Current (Amps)<br />
Operating Starting<br />
Open<br />
Circuit<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
% Dim. Wiring<br />
Dia.<br />
ELECTROMAGNETIC<br />
COMPACT<br />
FT18W/2G11 - 18W Long Twin Tube Lamp (PL-L18, F18BX, FT18DL) - Separate Starter Required<br />
1 18 50 120<br />
Above Units Available for Outdoor Fixtures labeled “Outdoor<br />
Use Only.” Eliminate TP from Catalog Number.<br />
◆ Open Core & Coil <strong>Ballasts</strong> are available without mounting feet—<br />
Add Suffix -A to Calalog Number. Units without mounting feet<br />
are UL Component Recognized.<br />
★ Core & Coil with Cover, painted white<br />
ƒ For Outdoor Use Only<br />
WHITE<br />
LINE<br />
BLACK<br />
CAP<br />
OPTIONAL<br />
BALLAST<br />
Diag. 44<br />
S<br />
BLUE<br />
LC-25-TP ★ ✓ ✓ 0.39 0.59 — 22 1.05
ELECTROMAGNETIC BALLASTS<br />
2-Pin Compact Lamps<br />
Preheat <strong>Ballasts</strong><br />
T4<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog ✧<br />
Number<br />
Certifications<br />
Line Current (Amps)<br />
Operating Starting<br />
Open<br />
Circuit<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
% Dim. Wiring<br />
Dia.<br />
CFT5W/G23 - 5W Twin Tube Lamp (PL-S5W, F5BX, CF5DS)<br />
0 L-1B9-TP ❉ ✓ ✓ 0.19 0.20 — 11 1.00
T4<br />
ELECTROMAGNETIC BALLASTS<br />
2-Pin Compact Lamps<br />
Preheat <strong>Ballasts</strong><br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog ✧<br />
Number<br />
Certifications<br />
Line Current (Amps)<br />
Operating Starting<br />
Open<br />
Circuit<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Dim.<br />
Wiring<br />
Dia.<br />
CFQ13W/G24d - 13W Quad Tube Lamp (PL-C13W, F13DBXT4)<br />
1 13 0 120 L-1Q13-TP -W❉ ✓ ✓ 0.35 0.19 — 18 0.93
ELECTROMAGNETIC BALLASTS<br />
2-Pin Compact Lamps<br />
Preheat <strong>Ballasts</strong><br />
T4 and T5<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog✧<br />
Number<br />
Certifications<br />
Line Current (Amps)<br />
Operating Starting<br />
Open<br />
Circuit<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
% Dim. Wiring<br />
Dia.<br />
CFQ18WG24d - 18W Quad Tube Lamp (PL-C18W, F18DBXT4, CF18DD)<br />
CFTR18W/GX24d - 18W Triple Tube Lamp (CF18DT)<br />
1 18 50<br />
120<br />
L-1Q18-TP ❉ ✓ ✓ 0.48 0.27 — 25 0.96
T4 and T6<br />
ELECTROMAGNETIC BALLASTS<br />
2D Square Shaped Lamps<br />
Preheat <strong>Ballasts</strong><br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog✧<br />
Number<br />
Certifications<br />
Line Current (Amps)<br />
Operating Starting<br />
Open<br />
Circuit<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
% Dim. Wiring<br />
Dia.<br />
ELECTROMAGNETIC<br />
COMPACT<br />
CFS21W/GR10q - 21W 2D Lamp (F21 2D/4P) - Separate Starter Required<br />
L-1Q26-TP ❉ ✓ ✓ 0.66 0.46 — 32 0.98<br />
1 21 25 120<br />
H-1Q26-TP ✓ ✓ 0.23 0.33 0.41 26 0.82<br />
CFS28W/GR8 - 28W 2D Lamp (F28 2D)<br />
L-140-F-TP ❉ ✓ ✓ 0.70 — — 39 0.94<br />
1 28 25 120 L-1Q26-TP ❉ ✓ ✓ 0.63 0.46 — 35 0.97<br />
H-1Q26-TP ✓ ✓ 0.24 0.33 0.41 28 0.80<br />
CFS28W/GR10q - 28W 2D Lamp (F38 2D/4P) - Separate Starter Required<br />
1 28 50 120 LX-140-F-TP ❉ ✩ ✓ ✓ 0.63 — — 40 1.02<br />
✧ Ordering Information<br />
Add suffix -W to Catalog Number for white can<br />
with leads exiting end of ballast.<br />
Add suffix -BLS to Catalog Number for black can<br />
with bottom leads and studs.<br />
❉ Normal Power Factor<br />
✩ Ballast includes built-in starter<br />
BLK/WHT<br />
BLACK<br />
DIMENSIONS<br />
Designation<br />
Length (L)<br />
(inches)<br />
Width (W)<br />
(inches)<br />
Height (H)<br />
(inches)<br />
Mounting (M)<br />
(inches)<br />
R-4 6¹₂ 1¹⁵₁₆ 1³₈ 6 +<br />
T-1 6¹₂ 2³⁄₈ 1¹⁄₂ 6 +<br />
+ Mounting dimensions refer to slots only<br />
ELECTROMAGNETIC BALLASTS<br />
Long Twin Tube Lamps<br />
Rapid Start <strong>Ballasts</strong><br />
FT5<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
FT18W/2G11/RS - 18W Long Twin Tube Lamp (F18BX/RS, FT18DL/RS)<br />
1<br />
2<br />
18<br />
18<br />
50<br />
50<br />
120<br />
120<br />
R-1P817-TP<br />
R-2P817-TP<br />
✓<br />
✓<br />
✓<br />
✓<br />
0.22<br />
0.41<br />
25<br />
47<br />
1.01<br />
0.98<br />
T12/HO<br />
Weatherproof<br />
ELECTROMAGNETIC BALLASTS<br />
High Output<br />
Rapid Start Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED C<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
ELECTROMAGNETIC<br />
WEATHERPROOF<br />
F24T12/HO (800mA)<br />
2 35 -20 120 RC-2S85-FO ✓ 1.01 95 0.78
ELECTROMAGNETIC BALLASTS<br />
Very High Output<br />
VHO & Powergroove Rapid Start Lamps<br />
T10 and T12/VHO<br />
HIGH POWER FACTOR<br />
SOUND RATED D<br />
Weatherproof<br />
Lamp Data<br />
Number<br />
Watts<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
THD<br />
%<br />
Power<br />
Factor<br />
Dim. Wiring<br />
Dia.<br />
F48T10/VHO (1500mA)<br />
F48T12/VHO (1500mA)<br />
F48PG17/VHO (1500mA)<br />
1 116 -20<br />
120 RC-2S102-FO ✓ 1.70 130 0.87
T12/HO<br />
Sign<br />
ELECTROMAGNETIC BALLASTS<br />
High Output<br />
Rapid Start Lamps<br />
CLASS P BALLAST IN WHITE CAN<br />
Lamp Data<br />
No. of Lamp Footage<br />
Lamps Min Max<br />
Min.<br />
Starting<br />
Temp.<br />
(F)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Certifications<br />
Max. Line<br />
Current<br />
(Amps)<br />
Max. Input<br />
Power<br />
(Watts)<br />
Open<br />
Circuit<br />
Volts<br />
Dim.<br />
Wiring<br />
Dia.<br />
T12/HO (800mA)<br />
1,2<br />
2, 3, 4<br />
2, 3, 4<br />
2, 3, 4<br />
4<br />
6<br />
12<br />
20•<br />
12<br />
20<br />
24<br />
40•<br />
-20°F<br />
120<br />
277<br />
120<br />
277<br />
120<br />
277<br />
120<br />
277<br />
ASB-0412-12-BL-TP<br />
VSB-0412-12-BL-TP<br />
ASB-0620-24-BL-TP<br />
VSB-0620-24-BL-TP<br />
ASB-1224-24-BL-TP<br />
VSB-1224-24-BL-TP<br />
ASB-2040-24-BL-TP<br />
VSB-2040-24-BL-TP<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
1.48<br />
0.65<br />
2.56<br />
1.12<br />
2.70<br />
1.15<br />
4.00<br />
1.75<br />
175<br />
304<br />
312<br />
472<br />
480<br />
720<br />
785<br />
720<br />
BL-1<br />
BL-1<br />
BL-2<br />
BL-3<br />
21, 39<br />
5, 8, 13<br />
7, 9, 13<br />
5, 9, 13<br />
3, 4<br />
24<br />
32<br />
120<br />
ASB-2432-34-BL-TP<br />
✓<br />
✓<br />
3.30<br />
370<br />
975<br />
BL-4<br />
8, 13<br />
ELECTROMAGNETIC<br />
SIGN<br />
120 ASB-1240-46-BL-TP ✓ ✓<br />
4, 5, 6 12▼ 40▼<br />
277 VSB-1240-46-BL-TP ✓ ✓<br />
120 ASB-2448-46-BL-TP ✓ ✓<br />
4, 5, 6 24■ 48■<br />
277 VSB-2448-46-BL-TP ✓ ✓<br />
● Total lamp length of each circuit (A) and (B) must not be less than 10 ft. nor more than 20 ft.<br />
Circuit (A) is comprised of lamps 1,2. Circuit (B) is comprised of lamps 3,4. (See wiring diagrams).<br />
▼ Total lamp length of each circuit (A) and (B) must not be less than 6 ft. nor more than 20 ft.<br />
Circuit (A) is comprised of lamps 1,2,3. Circuit (B) is comprised of lamps 4,5,6. (See wiring diagrams).<br />
■ Total lamp length of each circuit (A) and (B) must not be less than 12 ft. nor more than 24 ft.<br />
Circuit (A) is comprised of lamps 1,2,3. Circuit (B) is comprised of lamps 4,5,6. (See wiring diagrams).<br />
3.90<br />
1.70<br />
5.19<br />
2.25<br />
462<br />
604<br />
720<br />
720<br />
BL-3<br />
BL-3<br />
14, 15, 19<br />
14, 15, 19<br />
LAMP<br />
BALLAST<br />
LINE<br />
BLACK<br />
WHITE<br />
BROWN<br />
BROWN<br />
YELLOW<br />
BALLAST<br />
BLUE<br />
BLUE<br />
BLUE-WH<br />
BLUE-WH<br />
RED<br />
YELLOW<br />
RED<br />
LINE<br />
* YEL<br />
* YEL<br />
WHITE<br />
BLACK<br />
BALLAST<br />
BLUE<br />
BLUE<br />
RED<br />
RED<br />
LAMP 2<br />
*FOR INSULATE<br />
*FOR SINGLE LAMP OPERATION, INSULATE<br />
FOR 600V<br />
YELLOW LEADS INDIVIDUALLY FOR 600V<br />
Diag. 39<br />
Diag. 39<br />
Note: insulate unused leads individually<br />
as shown on ballast label<br />
Diag. 5<br />
LAMP 3<br />
Note: insulate unused leads individually<br />
as shown on ballast label<br />
Diag. 7<br />
Note: Insulate unused leads individually as shown on ballast label<br />
Diag. 7<br />
LINE<br />
BLACK<br />
WHITE<br />
BROWN<br />
BROWN<br />
YELLOW<br />
YELLOW<br />
BALLAST<br />
BLUE<br />
BLUE<br />
BLUE-WH<br />
BLUE-WH<br />
RED<br />
RED<br />
LINE<br />
BLACK<br />
WHITE<br />
BROWN<br />
BROWN<br />
YELLOW<br />
YELLOW<br />
BALLAST<br />
BLUE<br />
BLUE<br />
BLUE-WH<br />
BLUE-WH<br />
RED<br />
RED<br />
LINE<br />
BLACK<br />
WHITE<br />
BROWN<br />
BROWN<br />
YELLOW<br />
YELLOW<br />
BALLAST<br />
BLUE<br />
BLUE<br />
BLUE-WH<br />
BLUE-WH<br />
RED<br />
RED<br />
LINE<br />
BLACK<br />
WHITE<br />
BROWN<br />
BROWN<br />
BLUE-WH<br />
BLUE-WH<br />
YELLOW<br />
YELLOW<br />
BALLAST<br />
BLUE<br />
BLUE<br />
OR-BLK<br />
OR-BLK<br />
ORANGE<br />
ORANGE<br />
RED<br />
RED<br />
LAMP 1<br />
LAMP 1<br />
LAMP 1<br />
LAMP 2<br />
LAMP 3<br />
LAMP 2<br />
LAMP 2<br />
LAMP 3<br />
LAMP 3<br />
LAMP 3<br />
LAMP 4<br />
Note: Insulate unused Note: leads insulate individually as unused shown on ballast leads labelindividually<br />
Diag. 8<br />
as shown on ballast label<br />
Diag. 8<br />
LAMP 4<br />
Note: insulate unused leads individually<br />
as shown on ballast label<br />
Diag. 9<br />
Note: Insulate unused leads individually as shown on ballast label<br />
Diag. 9<br />
LAMP 4<br />
Diag. 13<br />
LAMP 6<br />
Note: Insulate unused leads individually as shown on ballast label<br />
Note: insulate unused leads individually<br />
as shown on ballast label<br />
Diag. 14<br />
Diag. 14<br />
LINE<br />
BLACK<br />
WHITE<br />
BROWN<br />
BROWN<br />
BLUE-WH<br />
BLUE-WH<br />
YELLOW<br />
YELLOW<br />
BALLAST<br />
BLUE<br />
BLUE<br />
OR-BLK<br />
OR-BLK<br />
ORANGE<br />
ORANGE<br />
RED<br />
RED<br />
LINE<br />
BLACK<br />
WHITE<br />
BROWN<br />
BROWN<br />
BLUE-WH<br />
BLUE-WH<br />
YELLOW<br />
YELLOW<br />
BALLAST<br />
BLUE<br />
BLUE<br />
OR-BLK<br />
OR-BLK<br />
ORANGE<br />
ORANGE<br />
RED<br />
RED<br />
LAMP 1<br />
LAMP 1<br />
LAMP 2<br />
LAMP 3<br />
LAMP 3<br />
LAMP 4<br />
LAMP 4<br />
LAMP 5<br />
LAMP 5<br />
3-40<br />
LAMP 6<br />
Note: Insulate unused leads individually as shown on ballast label<br />
Note: insulate unused leads individually<br />
as shown on ballast label<br />
Diag. 15<br />
Diag. 15<br />
LAMP 6<br />
Diag. 19<br />
Diag. 19<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
ELECTROMAGNETIC BALLASTS<br />
High Output<br />
Rapid Start Lamps<br />
CLASS P BALLAST IN WHITE CAN<br />
T12/HO<br />
Sign<br />
Total Lamp Feet<br />
Number of Lamps<br />
per Ballast<br />
1,2<br />
2,3,4<br />
2,3,4<br />
2,3,4<br />
3,4<br />
4,5,6<br />
4,5,6<br />
To select the ballast for your particular plastic sign application:<br />
1) Determine the total number of lamp feet required (from 4 to 48 feet) and read down to select the proper <strong>Advance</strong> Catalog Number. Note<br />
that the first ballast you come to, reading down the chart, will be the most economical for your application.<br />
2) The number of lamps per ballast is shown in the left column.<br />
DIMENSIONS<br />
PC-161W<br />
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50<br />
ASB-0412-12-BL-TP<br />
VSB-0412-12-BL-TP<br />
ASB-0620-24-BL-TP<br />
VSB-0620-24-BL-TP<br />
ASB-1224-24-BL-TP<br />
VSB-1224-24-BL-TP<br />
ASB-2040-24-BL-TP<br />
VSB-2040-24-BL-TP<br />
ASB-2432-34-BL-TP<br />
PC-857W<br />
ASB-1240-46-BL-TP<br />
VSB-1240-46-BL-TP<br />
Designation<br />
Length (L)<br />
(inches)<br />
ASB-2448-46-BL-TP<br />
VSB-2448-46-BL-TP<br />
H<br />
Width (W)<br />
(inches)<br />
C<br />
Height (H)<br />
(inches)<br />
Mounting (M)<br />
(inches)<br />
BL-1 11³₄ 3³₁₆ 2⁵₈ 11⁹₆₄<br />
BL-2 14⁵₁₆ 3³₁₆ 2⁵₈ 13³₄<br />
BL-3 19³₁₆ 3³₁₆ 2¹¹₁₆ 18⁵₈<br />
BL-4 16¹¹₁₆ 3³₁₆ 2⁵₈ 16⁹₆₄<br />
ELECTROMAGNETIC<br />
SIGN<br />
Case BL-1, BL-2, BL-3<br />
HID SIGN BALLASTS___________________________________________________________<br />
Input<br />
Voltage<br />
Circuit<br />
Type<br />
Catalog<br />
Number<br />
Operating<br />
150 Watt Lamp, ANSI Code M102 (Medium Base)<br />
120 HX-HPF ASB-150-M102-BL 1.60 1.50 3.65 180 240 10 BL-2 13.00 10<br />
60HZ., minimum starting temperature -20Þ F or -30Þ C.<br />
Input Amps<br />
Starting<br />
Open<br />
Circuit<br />
Input<br />
Watts<br />
Nom.<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
Amps<br />
W 2"<br />
Dimensions<br />
L<br />
M<br />
Certification<br />
Total<br />
Wt.<br />
(Lbs)<br />
Max. Ballast<br />
to Lamp<br />
Distance (ft)<br />
Wiring Diagram<br />
All leads lengths 12”<br />
Ground case<br />
BALLAST<br />
120V Common<br />
Blk<br />
White<br />
Red<br />
Lamp<br />
DIMENSIONS<br />
Designation<br />
Length (L)<br />
(inches)<br />
Width (W)<br />
(inches)<br />
Height (H)<br />
(inches)<br />
Mounting (M)<br />
(inches)<br />
BL-2 14⁵₁₆ 3³₁₆<br />
2⁵₈ 13³₄<br />
Refer to pages 8-17 to 8-19 for lead lengths and shipping data<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
3-41
ELECTRONIC HID BALLASTS<br />
ELECTRONIC HID<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
ELECTRONIC HID BALLASTS<br />
Contents<br />
General Information............................................................................4-2<br />
e-Vision ® ...................................................................................4-3 to 4-7<br />
DynaVision ..........................................................................4-8 to 4-10<br />
ELECTRONIC HID<br />
Corporate Offices<br />
(800) 322-2086<br />
Customer Support/Technical Service<br />
(800) 372-3331 • (+) 1 847 390-5000 (International)<br />
Visit our web site at www.advancetransformer.com<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 4-1
ELECTRONIC HID BALLASTS<br />
Just as electronic ballast technology enhanced fluorescent lighting systems, electronic HID<br />
ballasts bring significant performance improvements to HID lighting systems:<br />
• Higher efficiency<br />
• Greater lumen maintenance<br />
• Longer lamp life<br />
• Enhanced color control<br />
Low frequency electronic ballasts are recommended by lamp manufacturers to drive the<br />
new generation of ceramic, low wattage metal halide lamps. These ceramic lamps have<br />
superior color rendition and can potentially maintain that color over the life of the lamps.<br />
However, as color is a function of lamp wattage, the ballast must be able to maintain<br />
lamp wattage precisely at its rated point throughout the entire life of the lamp. Low<br />
frequency electronic HID ballasts such as <strong>Advance</strong> Transformer’s e-Vision ® line<br />
constantly measure and adjust the wattage, optimizing delivery of the ceramic lamps’<br />
superior color properties. This makes metal halide a viable choice for many<br />
applications previously lit by either tungsten halogen or incandescent sources, such as<br />
retail lighting.<br />
Operational improvements are gained as greater efficiency and cooler running electronic<br />
ballasts lead to energy savings. In addition, ballasts run quieter, weigh less and have<br />
compact footprints.<br />
ELECTRONIC HID<br />
Improved lumen maintenance – the lamp/ballast system’s ability to minimize light output<br />
depreciation over the life of the lamp – is the most fundamental and significant benefit of<br />
electronic HID ballasts, especially medium wattage, high frequency ballasts such as<br />
<strong>Advance</strong>’s DynaVision ballast. DynaVision delivers a 30-50% improvement in lumen<br />
maintenance over conventional HID systems (magnetic ballasts driving probe-start metal<br />
halide lamps) and a 19% improvement over pulse-start systems. Conventional HID systems<br />
typically experience a 50-60% fall-off in light output over the published life of the lamp. By<br />
maintaining higher light levels across the entire published life of the lamp, electronic HID<br />
ballasts reduce the need for frequent re-lamping.<br />
With more maintained lumens the overall fixture count can be significantly reduced.<br />
For example, a 400w DynaVision system produces up to 56% more mean lumens over a<br />
400w probe-start system with magnetic ballasts. Taking advantage of this performance<br />
benefit, the fixture count can be reduced by up to 36% without sacrificing light levels.<br />
Fewer fixtures also lead to much lower operating costs in terms of both energy<br />
savings and maintenance.<br />
Dimming (to 50% power) with lighting controls such as relays, occupancy sensors,<br />
building management systems (BMS) and, in the future, digitally addressable lighting<br />
systems (such as DALI) are also possible with DynaVision electronic HID ballasts.<br />
The DynaVision ballast also incorporates microprocessor-based technology which provides<br />
comprehensive lamp and ballast parameter control and is a solid platform for the future.<br />
4-2<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
e-Vision® LOW FREQUENCY ELECTRONIC HID BALLASTS<br />
For Low Wattage HID Lamps<br />
Key Features<br />
IntelliVolt ®<br />
• Operates on either 120 or 277 volts, or any<br />
voltage in between, 50 or 60 Hz<br />
Smaller and lighter weight than magnetic HID<br />
F-Can ballasts<br />
Reduced input watts compared to magnetic systems<br />
Low frequency lamp operation<br />
Square wave output waveform<br />
Lamp EOL detection; Safely shuts down system at<br />
lamp end of life<br />
Thermally protected, internally fused, and output<br />
short circuit protected<br />
Excellent lamp wattage regulation<br />
• Lamp wattage will change less than .5% with a<br />
+/-10% change in line voltage<br />
Metallic enclosure<br />
Key Benefits<br />
• Fewer SKUs required in inventory<br />
• Broadens the range of applications<br />
• Compact electronic HID footprints<br />
• Provides greater design flexibility<br />
• Energy Savings; Lower cost of ownership<br />
• Prevents acoustic resonance in the lamp arc tube<br />
• Recommended by lamp manufacturers<br />
• Maximizes lamp life<br />
• Enhanced safety<br />
• Safely shuts system down upon<br />
abnormal failure or conditions<br />
Better light quality<br />
• Optimizes lamp color stability over life<br />
• Reduces lamp-to-lamp color variations<br />
both initially and during lamp life<br />
• Provides enhanced capability for high ambient<br />
temperatures by transferring heat away from<br />
sensitive internal components<br />
1.0 Ballast Factor<br />
e-Vision <strong>Electronic</strong> Ballast Catalog Number Explanation<br />
I ZT – MH – _ 100 – A – BLS<br />
• Lamp produces maximum light output over it’s<br />
entire life.<br />
ELECTRONIC HID<br />
e-Vision ®<br />
Lead Exit / Mounting Options:<br />
BLS = Bottom Leads with Studs<br />
LF = Leads (side exit) with mounting Feet<br />
LFS = Leads (side exit, lead exit from same end) with mounting Feet (RMH-39-K Only)<br />
Can Material / Size: (Dimensions include mounting feet)<br />
A = Metal case with dim. 5.5” L x 3.6” W x 1.5” H<br />
C = Metal case with dim. 8.0” L x 3.6” W x 1.5” H<br />
D = Metal case with dim. 5.0” L x 3.0” W x 1.5” H<br />
E = Metal case with dim. 5.5” L x 1.75” W x 1.2” H<br />
G = Metal case with dim. 3.9” L x 3.0” W x 1.2” H<br />
H = Metal case with dim. 6.4” L x 3.7” W x 1.5” H<br />
J = Metal case with dim. 5.9” L x 1.8” W x 1.2” H<br />
K = Metal case with dim. 4.75” L x 1.3” W x 1.2” H<br />
Maximum Lamp Wattage<br />
20 = 22W Lamp (Philips MiniMaster Color Lamp) 39 = 39W Lamp 50 = 50W Lamp 70W = 70W Lamp<br />
100 = 100W Lamp 150 = 100W Lamp 175 = 175W Lamp 200W = 200W Lamp<br />
(Some ballasts are dual voltage - See product table)<br />
Number of Lamps: Blank = 1 Lamp Operations 2 = (2) Lamp Operation<br />
Primary Lamp Type:<br />
MH = Metal Halide<br />
WSN = Mini whiteSON (100W ONLY)<br />
SN = High Pressure Sodium<br />
Dimming Scheme: Blank = Fixed Light Output ZT = 0-10V Dimming<br />
Input Voltage:<br />
I = Intellivolt (accepts input of 120 thru 277V, 50/60 Hz nominal)<br />
R = 120V, 50/60 Hz nominal)<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 4-3
e-Vision® LOW FREQUENCY ELECTRONIC HID BALLASTS<br />
For Low Wattage HID Lamps<br />
e-Vision ® <strong>Electronic</strong> Ballast Specifications<br />
<strong>Section</strong> 1 - Physical Characteristics<br />
1.0 The electronic ballast shall be furnished with integral, colorcoded<br />
leads.<br />
<strong>Section</strong> II - Performance Requirements<br />
2.0 The electronic ballast shall be IntelliVolt ® and operate from a<br />
nominal line voltage range of 120-277 volts, +/-10%, 50/60 Hz.<br />
2.1 The electronic ballast input current shall have Total Harmonic<br />
Distortion (THD) of less than 15%.<br />
2.2 The electronic ballast shall have a Power Factor greater than 90%.<br />
2.3 The electronic ballast shall have a lamp end-of-life detection<br />
and shutdown circuit.<br />
2.4 The electronic ballast shall be Sound Rated A.<br />
2.5 The electronic ballast output frequency to the lamps shall be<br />
less than 200 Hz to prevent acoustic resonance inside the lamp<br />
arc tube and to minimize visible flicker.<br />
2.6 The electronic ballast shall provide a “Lamp Current Crest<br />
Factor” of less than 1.5.<br />
2.7 The electronic ballast shall be thermally protected to shut off<br />
when operating temperatures reach unacceptable levels.<br />
<strong>Section</strong> III - Regulatory Requirements<br />
3.0 The electronic ballast shall meet the requirements of the Federal<br />
Communications Commission rules and regulations, Title 47 CFR<br />
part 18, for Non-Consumer equipment.<br />
3.1 The electronic ballast shall be Underwriters Laboratories (UL)<br />
Listed and CSA Certified where applicable.<br />
<strong>Section</strong> IV - Other<br />
4.0 The electronic ballast shall not contain Polychlorinated Biphenyl<br />
(PCB’s).<br />
4.1 The electronic ballast shall carry a three-year warranty from the<br />
date of manufacture for operation at marked maximum case<br />
temperature or less.<br />
4.2 The manufacturer shall have a twenty-five year history of producing<br />
HID lamp ballasts for the North American market.<br />
4.3 The electronic ballast shall be produced in a factory certified to<br />
ISO 9002 Quality System Standards<br />
Installation Notes<br />
1. Red lead must be connected to center terminal of lamp (for Edison. screw base lamps). Do not connect red or blue lead to neutral or ground.<br />
2. Use 4.0 kV pulse rated lampholder. (Except where special lampholder is required, such as 22W Philips Mini MasterColor Lamp).<br />
3. Maximum ballast-to-lamp distance is 5 ft. using typical wiring methods and materials. Additional distance up to 15 ft. may be possible using<br />
wire between lamp and ballast with a total measured capacitance of 100 picofarads or less. Consult <strong>Advance</strong> for application assistance.<br />
4. Power mains must be cycled off and then on to reset ballast after failed lamps are replaced.<br />
ELECTRONIC HID<br />
e-Vision ®<br />
Ballast Hot Spot Location<br />
Hot spot locations differ with each ballast model and are designated on the individual ballast labels. Consult ballast labels and ballast<br />
specification sheets for Hot Spot locations.<br />
Enclosure Dimensions, Lead Lengths and Wiring Diagrams<br />
Fig 1 Fig 2 Fig 3<br />
(Red)<br />
(Red)<br />
(Blue)<br />
Lamp<br />
(Blue)<br />
Lamp<br />
Ballast<br />
(White/Black)<br />
Ballast<br />
(White)<br />
Com<br />
(White)<br />
(Black)<br />
120V - 277V<br />
(Black)<br />
(Green)<br />
120V - 277V<br />
Com<br />
Ballast Case must<br />
be Grounded<br />
Ballast Case must<br />
be Grounded<br />
Fig 4<br />
(Red)<br />
kV<br />
Lamp<br />
Fig 5<br />
(Red)<br />
kV<br />
Lamp 1<br />
kV<br />
Fig 6<br />
(Blue)<br />
(Red)<br />
Lamp<br />
Ballast<br />
(Black)<br />
(Blue)<br />
(White)<br />
120V<br />
Com<br />
Ballast<br />
(Blue)<br />
(Orange) Lamp 2<br />
(Brown)<br />
(White)<br />
Com<br />
(Black)<br />
120V - 277V<br />
Ballast<br />
(Violet) Dim +<br />
(Gray)<br />
Dim -<br />
(White)<br />
Com<br />
(Black)<br />
120V - 277V<br />
(Green)<br />
Ballast Case must<br />
be Grounded<br />
Ballast Case must<br />
be Grounded<br />
Ballast Case must<br />
be Grounded<br />
4-4<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
e-Vision® LOW FREQUENCY ELECTRONIC HID BALLASTS<br />
For Low Wattage HID Lamps<br />
Metal Halide and High Pressure Sodium<br />
Lamp Data<br />
Number<br />
Watts<br />
Input<br />
Volts<br />
Catalog Number*<br />
Note 1<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Max.<br />
Case<br />
Temp.<br />
Note 6<br />
Wiring<br />
Diag.<br />
Fig.<br />
Weight<br />
(lb)<br />
Max.<br />
Distance to<br />
Lamp (ft)<br />
New<br />
New<br />
New<br />
New<br />
New<br />
New<br />
New<br />
New<br />
22 Watt Lamp, Philips Mini MasterColor, ANSI Code M175, Minimum Starting Temp. -20°C/-4°F<br />
1 22 120<br />
RMH-20-E-LF<br />
✓ ✓ 0.23 26 70°C 4 E 0.4<br />
RMH-20-E-BLS<br />
39 Watt Lamp, ANSI Code M130, Minimum Starting Temp. -30°C/-20°F<br />
RMH-39-K-LF or<br />
1 39 120 RMH-39-K-LFS<br />
✓ ✓ 0.40 45 90°C 4 K 0.5 6<br />
Note 2<br />
1 39<br />
120 IMH-39-G-LF or<br />
✓ ✓ 0.39 46<br />
277 IMG-39-G-BLS<br />
✓ ✓ 0.18 45<br />
90°C 3 G 0.9 5<br />
1 39<br />
120<br />
✓ ✓ 0.39 46<br />
277<br />
IMH-39-J-LF<br />
✓ ✓ 0.18 45<br />
90°C 3 J 0.9 5<br />
1 39<br />
120<br />
IMH-50-A-LF or<br />
✓ ✓ 0.38 45<br />
277<br />
IMH-50-A-BLS<br />
Note 3<br />
✓ ✓ 0.16 44<br />
85°C 1 A 1.4 5<br />
2 39<br />
120 IMH-239-A-LF or<br />
✓ ✓ 0.74 89<br />
277 IMG-239-A-BLS<br />
✓ ✓ 0.31 89<br />
85°C 5 A 1.7 6<br />
50 Watt Lamp, ANSI Code M110, Minimum Starting Temp. -30°C/-20°F<br />
1 50<br />
120<br />
IMH-50-A-LF or<br />
✓ ✓ 0.47 56<br />
277<br />
IMH-50-A-BLS<br />
Note 3<br />
✓ ✓ 0.20 55<br />
85°C 2<br />
70 Watt Lamp, ANSI Code M98 or M143 or M139, Minimum Starting Temp. -30°C/-20°F<br />
1 70<br />
120 IMH-70-G-LF or<br />
✓ ✓ 0.67 80<br />
277 IMG-70-G-BLS<br />
✓ ✓ 0.30 79<br />
90°C 3<br />
1 70<br />
120<br />
✓ ✓ 0.67 80<br />
277<br />
IMH-70-J-LF<br />
✓ ✓ 0.30 79<br />
90°C 3<br />
1 70<br />
120 IMH-70-D-LF or<br />
✓ ✓ 0.67 80<br />
277 IMH-70-D-BLS<br />
✓ ✓ 0.29 79<br />
85°C 3<br />
1 70<br />
120<br />
IMH-100-A-LF or<br />
✓ ✓ 0.68 82<br />
277<br />
IMG-100-A-BLS<br />
Note 4<br />
✓ ✓ 0.30 81<br />
85°C 1<br />
6<br />
A 1.4 5<br />
G 0.9 5<br />
J 0.9 5<br />
D 1.6 5<br />
A 1.4 5<br />
ELECTRONIC HID<br />
e-Vision ®<br />
Notes:<br />
1. All ballasts are sound rated A, and feature high power factor (>0.9, a ballast factor of 1.0 resettable thermal protection, and a maximum Harmonic Distortion of 15%.<br />
2. For RMH-39-K-LF, input and output lead wires exit on opposite sides of ballast. For RMH-39-K-LFS, all lead wires exit the same side of the ballast.<br />
3. A dual-wattage ballast for 39W or 50W MH<br />
4. A dual-wattage ballast for 70W or 100W MH<br />
5. A dual-wattage ballast for 150W or 175W MH<br />
6. Maximum case temperature should not be exceeded in the application, as life will be affected and the integral re-settable thermal protector may activate. A lower<br />
maximum temperature rating does not imply lesser thermal performance, and can be indicative of a cooler running ballast design. Consult factory for further<br />
application assistance.<br />
7. Also operates (1) 150W HPS S56 (100V) Lamp<br />
* Ordering information:<br />
–LF Side exit leads with mounting feet<br />
–BLS Bottom exit leads with mounting studs<br />
For ballast diagrams see page 4-7<br />
Wire Color<br />
Function Lengths Lead Lengths Length Strip<br />
(-LF model) (-BLS model)<br />
Black Input Power 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />
White Input Power 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />
Black/White Lamp Power Selection (IMH models only) 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />
Red Lamp Base 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />
Blue Lamp Screwshell 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />
Green Ground 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />
Orange Lamp Base 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />
Brown Lamp Screwshell 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 4-5
e-Vision LOW FREQUENCY ELECTRONIC HID BALLASTS<br />
For Low Wattage Metal Halide Lamps<br />
Metal Halide and High Pressure Sodium<br />
Lamp Data<br />
Number<br />
Watts<br />
Input<br />
Volts<br />
Catalog Number*<br />
Note 1<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Max.<br />
Case<br />
Temp.<br />
Note 6<br />
Wiring<br />
Diag.<br />
Fig.<br />
Weight<br />
(lb)<br />
Max.<br />
Distance to<br />
Lamp (ft)<br />
New<br />
New<br />
100 Watt Lamp, ANSI Code M90 or M140, Minimum Starting Temp. -30°C/-20°F<br />
1 100<br />
120 IMH-100-D-LF or<br />
✓ ✓ 0.92 110<br />
277 IMG-100-D-BLS<br />
✓ ✓ 0.40 109<br />
85°C 3 D 1.6 5<br />
1 100<br />
120<br />
IMH-100-A-LF or<br />
✓ ✓ 0.93 112<br />
277<br />
IMH-100-A-BLS<br />
Note 4<br />
✓ ✓ 0.40 110<br />
85°C 2 A 1.4 5<br />
150 Watt Lamp, ANSI Code M102 or M142, Minimum Starting Temp. -30°C/-20°F<br />
1 150<br />
120 IMH-150-H-LF or<br />
✓ ✓ 1.4 165<br />
277 IMG-150-H-BLS<br />
✓ ✓ 0.6 161<br />
85°C 3 H 1.9 5<br />
1 150<br />
120<br />
IMH-175-C-LF or<br />
✓ ✓ 1.4 169<br />
277<br />
IMH-175-C-BLS<br />
Note 5,7 ✓ ✓ 0.6 166<br />
85°C 1 C 2.5 5<br />
175 Watt Pulse Start Lamp, ANSI Code M137 or M152 (Pulse Start), Minimum Starting Temp. -30°C/-20°F<br />
1 175<br />
120<br />
IMH-175-C-LF or<br />
✓ ✓ 1.7 194<br />
277<br />
IMH-175-C-BLS<br />
Note 5<br />
✓ ✓ 0.7 191<br />
85°C 2 C 2.5 5<br />
200 Watt Pulse Start Lamp, ANSI Code M136 (Pulse Start), Minimum Starting Temp. -30°C/-20°F<br />
1 200<br />
120<br />
2.0 229<br />
IMH-200-C-LF ✓ ✓<br />
277<br />
1.0 219<br />
85°C 3 C 2.5 5<br />
100 Watt Lamp, Philips Mini whiteSON (SDW-TG), ANSI Code S167 (Pulse Start), Min. Starting Temp. -20°C/-4°F<br />
120 IWSN-150-C-LF or<br />
✓ ✓ 0.9 165<br />
1 150<br />
85°C 3 C 1.9 5<br />
277 IWSN-150-C-BLS<br />
✓ ✓ 0.5 161<br />
ELECTRONIC HID<br />
e-VISION<br />
New<br />
New<br />
CONTROLLABLE BALLASTS WITH 0-10V DIMMING INTERFACE Note 8<br />
Lamp Data<br />
Number<br />
Watts<br />
Input<br />
Volts<br />
Notes:<br />
1. All ballasts are sound rated A, and feature high power factor (>0.9, a ballast factor of 1.0 resettable thermal protection, and a maximum Harmonic Distortion of 15%.<br />
2. For RMH-39-K-LF, input and output lead wires exit on opposite sides of ballast. For RMH-39-K-LFS, all lead wires exit the same side of the ballast.<br />
3. A dual-wattage ballast for 39W or 50W MH<br />
4. A dual-wattage ballast for 70W or 100W MH<br />
5. A dual-wattage ballast for 150W or 175W MH<br />
6. Maximum case temperature should not be exceeded in the application, as life will be affected and the integral re-settable thermal protector may activate. A lower<br />
maximum temperature rating does not imply lesser thermal performance, and can be indicative of a cooler running ballast design. Consult factory for further<br />
application assistance.<br />
7. Also operates (1) 150W HPS S56 (100V) Lamp<br />
* Ordering information:<br />
–LF Side exit leads with<br />
mounting feet<br />
–BLS Bottom exit leads with<br />
mounting studs<br />
Catalog Number*<br />
Note 1<br />
Certifications<br />
Line<br />
Current<br />
(Amps)<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Max.<br />
Case<br />
Temp.<br />
Note 6<br />
150 Watt Lamp, ANSI Code M102 or M142, Minimum Starting Temp. -30°C/-20°F<br />
120<br />
✓ ✓ 1.4 169<br />
1 150<br />
277<br />
IZTMH-150-C-LF<br />
85°C<br />
✓ ✓ 0.6 166<br />
150 Watt HPS Lamp, ANSI Code S56 (100V), Minimum Starting Temp. -30°C/-20°F<br />
120<br />
✓ ✓ 1.4 169<br />
1 150<br />
277<br />
IZTSN-150-C-LF<br />
85°C 6<br />
✓ ✓ 0.6 166<br />
Wiring<br />
Diag.<br />
For ballast diagrams see page 4-7<br />
Wire Color<br />
Function Lengths Lead Lengths Length Strip<br />
(-LF model) (-BLS model)<br />
Black Input Power 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />
White Input Power 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />
Black/White Lamp Power Selection (IMH models only) 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />
Red Lamp Base 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />
Blue Lamp Screwshell 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />
Green Ground 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />
Orange Lamp Base 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />
Brown Lamp Screwshell 11.0” +/- 1.0” 9.0” +3.0”/-2.0” 0.5”<br />
6<br />
Fig.<br />
Weight<br />
(lb)<br />
Max.<br />
Distance to<br />
Lamp (ft)<br />
C 2.5 5<br />
C 2.5 5<br />
4-6<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
e-Vision LOW FREQUENCY ELECTRONIC HID BALLASTS<br />
For Low Wattage Metal Halide Lamps<br />
Case<br />
Figure<br />
Overall<br />
Length<br />
Case<br />
Length<br />
Case<br />
Width<br />
Height Mounting<br />
Length<br />
Mounting<br />
Width<br />
A<br />
140mm<br />
[5.5"]<br />
120mm<br />
[4.7"]<br />
92mm<br />
[3.6"]<br />
38mm<br />
[1.5"]<br />
132mm<br />
[5.2"]<br />
73mm<br />
[2.9"]<br />
C<br />
204mm<br />
[8.0"]<br />
184mm<br />
[7.2"]<br />
92mm<br />
[3.6"]<br />
38mm<br />
[1.5"]<br />
195mm<br />
[7.7"]<br />
73mm<br />
[2.9"]<br />
H<br />
161mm<br />
[6.3"]<br />
144mm<br />
[5.7"]<br />
92mm<br />
[3.6"]<br />
38mm<br />
[1.5"]<br />
152mm<br />
[6.0"]<br />
73mm<br />
[2.9"]<br />
Case<br />
Figure<br />
Overall<br />
Length<br />
Case<br />
Length<br />
Case<br />
Width<br />
Height<br />
Mounting Mounting<br />
Length Width<br />
D<br />
128mm<br />
[5.0"]<br />
108mm<br />
[4.3"]<br />
77mm<br />
[3.0"]<br />
38mm<br />
[1.5"]<br />
118mm<br />
[4.6"]<br />
19mm<br />
[0.7"]<br />
Case<br />
Figure<br />
Overall<br />
Length<br />
Case<br />
Length<br />
Case<br />
Width<br />
Height<br />
Mounting Mounting<br />
Length Width<br />
E<br />
140mm<br />
[5.5"]<br />
127mm<br />
[5.0"]<br />
44mm<br />
[1.7"]<br />
30mm<br />
[1.2"]<br />
135mm<br />
[5.3"]<br />
26mm<br />
[1.0"]<br />
J<br />
149mm<br />
[5.9"]<br />
140mm<br />
[5.5"]<br />
46mm<br />
[1.8"]<br />
30mm<br />
[1.2"]<br />
145mm<br />
[5.7"]<br />
27mm<br />
[1.0"]<br />
ELECTRONIC HID<br />
e-VISION<br />
Case<br />
Figure<br />
Overall<br />
Length<br />
Case<br />
Length<br />
Case<br />
Width<br />
Height<br />
Mounting Mounting<br />
Length Width<br />
G<br />
97mm<br />
[3.8"]<br />
90mm<br />
[3.5"]<br />
77mm<br />
[3.0"]<br />
30mm<br />
[1.2"]<br />
87mm<br />
[3.4"]<br />
67mm<br />
[2.6"]<br />
Case<br />
Figure<br />
Overall<br />
Length<br />
Case<br />
Length<br />
Case<br />
Width<br />
Height<br />
Mounting Mounting<br />
Length Width<br />
K<br />
113mm<br />
[4.4"]<br />
104mm<br />
[4.1"]<br />
33mm<br />
[1.1"]<br />
30mm<br />
[1.2"]<br />
13.5mm<br />
[0.5"]<br />
114mm<br />
[4.5"]<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 4-7
DYNAVISION ELECTRONIC HID BALLASTS<br />
DynaVision extends the key benefits<br />
of magnetic pulse-start metal halide<br />
systems — energy efficiency and<br />
white light. With its very-high<br />
frequency operation, as well as<br />
its on-board microprocessor and<br />
standard features, DynaVision<br />
provides numerous additional<br />
benefits and advantages.<br />
DynaVision Features<br />
Microprocessor technology<br />
High frequency operation<br />
True constant wattage<br />
320/350/400 Tri-Wattage<br />
IntelliVolt 200-277V 50/60 Hz<br />
Integral 120V quartz tap<br />
and relay, 250W<br />
0-10V dimming with automatic<br />
15-minute warm up<br />
Benefits and Advantages<br />
Lower operating and maintenance costs<br />
Fewer fixtures<br />
Energy savings<br />
Fewer SKU’s<br />
Less chance for error<br />
Ease of change over<br />
to different wattage lamps<br />
Standby-lighting ready<br />
No special orders<br />
No special relay or control required<br />
Continuous dimming down to 50% power<br />
Additional energy savings through<br />
daylight harvesting and occupancy sensing<br />
0º to 55ºC ambient rating standard Greater reliability, flexibility and<br />
-40º to +40ºC ambient rating optional and applications opportunities<br />
Lamp End-of-Life Protection (EOL)<br />
Safety<br />
ELECTRONIC HID<br />
DYNAVISION<br />
Physical Characteristics<br />
2.3˝<br />
Optional<br />
junction box<br />
4.0˝<br />
Fully closed<br />
extruded aluminum<br />
housing with white finish<br />
3.7˝<br />
8.8˝ mounting<br />
dimensions<br />
DIP switch access<br />
for lamp wattage selection<br />
More about...<br />
Standby Lighting Versatility<br />
DynaVision’s 120-volt output is designed<br />
to operate one quartz (incandescent)<br />
standby lamp up to 250W. The quartz<br />
lamp on or off modes are determined by the<br />
HID lamp’s specific operating conditions.<br />
Once the HID lamp strikes, the quartz lamp<br />
automatically switches off when the HID<br />
lamp reaches 50% power.<br />
9.2˝ bracket end-to-end length<br />
8.0˝<br />
5.0˝<br />
Hot spot measurement<br />
location at screw<br />
4.4˝ mounting<br />
dimensions<br />
2.6˝<br />
Integral mounting brackets<br />
5mm mounting<br />
holes (4) for<br />
#10 screws<br />
Controllability<br />
DynaVision is dimmable – down to 50% of nominal lamp<br />
power, with no noticeable loss in color characteristics.<br />
With 0-10V dimming, and compatible with a host of<br />
products from most control manufacturers, DynaVision<br />
brings new flexibility and energy-saving strategies,<br />
such as daylight harvesting and occupancy sensing, to<br />
applications in the industrial, educational, government,<br />
hospitality, commercial and retail sectors.<br />
DynaVision <strong>Electronic</strong> Ballast<br />
Catalog Number Breakdown<br />
IZTEMH4003PS - XJ<br />
Basic Model Number<br />
Options<br />
I = IntelliVolt (200-277 50/60 Hz)<br />
ZT = Zero-to-ten volt dimming<br />
E = <strong>Electronic</strong><br />
MH = Metal Halide<br />
400 = 400W maximum<br />
3 = 3 wattage capability (320/350/400W)<br />
PS = Pulse-Start<br />
-XJ = Without junction box<br />
(i.e. junction box is included if this suffix is omitted).<br />
F = Low temperature version (-40ºC to+55ºC)<br />
4-8<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
DYNAVISION ELECTRONIC HID BALLASTS<br />
DynaVision <strong>Electronic</strong> Ballast Specifications<br />
<strong>Section</strong> I – Physical Characteristics<br />
1.1 The electronic ballast shall be fully enclosed in an aluminum<br />
housing painted white.<br />
1.2 The aluminum housing shall include a divided wiring compartment<br />
to separate the power leads from the control leads. All leads to be<br />
color-coded.<br />
2.8 The electronic ballast shall be Sound Rated A.<br />
2.9 The electronic ballast output frequency to the lamps shall be<br />
higher than 100 kHz to prevent acoustic resonance inside the<br />
lamp arc tube and to minimize visible flicker.<br />
2.10 The electronic ballast shall be thermally protected to shut off<br />
when operating temperatures reach unacceptable levels.<br />
<strong>Section</strong> II – Performance Requirements<br />
2.1 The electronic ballast shall be multivoltage capable and operate<br />
from a line voltage range of 180 – 305 volts, 50/60 Hz.<br />
2.2 The electronic ballast shall incorporate a microprocessor controller<br />
to provide for optimum starting and operation of the HID lamp.<br />
2.3 The electronic ballast input current shall have Total Harmonic<br />
Distortion (THD) of less than 15% when operated at nominal line<br />
voltage (200V, 208V, 230V, 240V, 277V).<br />
2.4 The ballast shall incorporate a 0-10V dimming interface and<br />
control the dimming function such that the HID lamp is allowed<br />
to warm up for fifteen minutes at full power before the lamp will<br />
be allowed to dim, regardless of the level of the 0-10V signal.<br />
10V applied to the dimming control leads, shall result in full<br />
light output. 0V applied, or shorting the control leads together,<br />
shall result in dimming to 50% of nominal lamp power.<br />
2.5 The ballast shall include a 120V/250W auxiliary output for stand-by<br />
incandescent lighting that shall include an integral control to turn<br />
the auxiliary lamp on and off. The integral control shall include a<br />
time-delay feature to keep the auxiliary lamp on until the HID<br />
lamp reaches 50% power.<br />
2.6 The electronic ballast shall have a Power Factor greater than 90%.<br />
2.7 The electronic ballast shall have a lamp end-of-life detection and<br />
shutdown circuit.<br />
<strong>Section</strong> III – Regulatory Requirements<br />
3.1 The electronic ballast shall meet the requirements of the Federal<br />
Communications Commission rules and regulations, Title 47 CFR<br />
part 18, for Non-Consumer equipment.<br />
3.2 The electronic ballast shall be Underwriters Laboratories (UL)<br />
Listed and CSA Certified where applicable.<br />
<strong>Section</strong> VI – Other<br />
4.1 The electronic ballast shall not contain Polychlorinated Biphenyl<br />
(PCB’s).<br />
4.2 The electronic ballast shall carry a three-year warranty from the<br />
date of manufacture for operation at an ambient temperature of<br />
55° C or less and when operated as a stand alone product<br />
(i.e.remotely from a lighting fixture housing). When operated<br />
within a lighting fixture housing, the same three-year warranty<br />
shall apply for a maximum ballast case hot spot temperature of<br />
76° C or less.<br />
4.3 The manufacturer shall have a twenty-five year history of producing<br />
HID lamp ballasts for the North American market.<br />
4.4 The electronic ballast shall be produced in a factory certified to<br />
ISO 9002 Quality System Standards.<br />
ELECTRONIC HID<br />
DYNAVISION<br />
Installation and Application Notes<br />
1. Red lead must be connected to center terminal of lamp.<br />
Do not connect red or blue lead to line neutral.<br />
2. Setting precaution with triple-wattage feature: Do not operate<br />
lower wattage lamp on a ballast which has been set for operation<br />
of higher wattage lamp. Short lamp life may result.<br />
3. Ballast output will shut off after 40 minutes maximum if lamp<br />
does not successfully ignite. Replace lamp and cycle mains to<br />
restore output.<br />
4. Use 4.0 kV pulse rated lampholder.<br />
5. Connect red lamp lead to 600Vrms, 3.5kV or UL style 1452 wire.<br />
6. Remote mounting distances not exceeding 15 ft. are possible with<br />
normal wiring methods. For distances greater than 15 ft., power<br />
losses in the wire can result in appreciable decline in actual lamp<br />
operating power. Consult <strong>Advance</strong> for application assistance.<br />
7. Mains must be cycled after replacing lamp.<br />
8. Ballast output exceeds 100kHz. Suitable test equipment is required<br />
for measurement.<br />
9. Ballast is suitable for recessed use. Do not install insulation above or<br />
within 3” of ballast sides.<br />
Where to Measure the Ballast Hot Spot<br />
Hot spot at forward screw location<br />
Side View<br />
Optional<br />
junction box<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 4-9
DYNAVISION ELECTRONIC HID BALLASTS<br />
Breaks New Ground in HID Performance<br />
Pulse-Start Metal Halide<br />
Min Input Max. Min. DIP<br />
Lamp Data Start Input Catalog Listings Line Power Ballast THD PF Switch<br />
Temp. Volts Number Current ANSI Factor % % Settings<br />
No. Watts (F/C) (A) (W)<br />
320 Watt Lamp, ANSI Code M132/M154<br />
Application Specifications<br />
New<br />
New<br />
New<br />
1 320 32/0 200 to IZTEMH4003PS 1.8 @ 200V 345 1.0 15 90<br />
-40/-40 277 IZTEMH4003PS-F 1.3 @ 277V<br />
350 Watt Lamp, ANSI Code M131<br />
1 350 32/0 200 to IZTEMH4003PS 1.9 @ 200V 375 1.0 15 90<br />
-40/-40 277 IZTEM4003PS-F 1.4 @ 277V<br />
400 Watt Lamp, ANSI Code M135/M155<br />
1 400 32/0 200 to IZTEMH4003PS 2.2 @ 200V 430 1.0 15 90<br />
-40/-40 277 IZTEM400EPS-F 1.6 @ 277V<br />
NOTE: These specifications apply to operation of pulse-start metal halide lamps with quartz arc-tube construction only.<br />
For operating compatibility with ceramic arc-tube lamps, consult <strong>Advance</strong>.<br />
Preset at Factory<br />
DIP switches are “on”<br />
in the down position<br />
ON<br />
ON<br />
ON<br />
ELECTRONIC HID<br />
DYNAVISION<br />
Dimming Feature<br />
With an integral, industry-standard 0-10V interface, the<br />
DynaVision electronic ballasts offer the capability to dim<br />
the lamp by lowering the wattage lamp, reducing energy<br />
consumption of the light fixture by up to 50%. Access to<br />
this interface is via the violet (+) and grey (-) dimming<br />
control leads. These leads can be connected to either a<br />
0-10V dimming control, (DynaVision ballast are compatible<br />
with standard 0-10V control devices available from many<br />
manufacturers) a 0-10V DC power supply, or with a switch.<br />
An open switch provides full lamp power, and a closed<br />
switch, short-circuiting the 0-10V wires, yields 50% lamp<br />
power. Control devices such as relays and occupancy sensors<br />
may also be used.<br />
A potentiometer may also be used. However, the value of<br />
the potentiometer is dependent on the number of ballasts<br />
connected. Consult <strong>Advance</strong> for guidance.<br />
In accordance with the requirements of the HID<br />
lamp manufacturers and NEMA, the dimming feature<br />
includes a time delay to allow the HID lamp to<br />
warm up for 15 minutes at full power before the<br />
lamps will be allowed to dim, regardless of the level<br />
of the 0-10V signal.<br />
Lead Wire Information<br />
Wire Color Function<br />
Black Input Power<br />
White Input Power<br />
Green Ground<br />
Red Lamp Eyelet<br />
Blue Lamp Screwshell<br />
Yellow (2) 120V Lamp Output<br />
Violet 0-10V Dimming (+)<br />
Grey 0-10V Dimming (-)<br />
All lead lengths<br />
are 11" +/- 1".<br />
The black & white<br />
(input power), green<br />
(ground), and red &<br />
blue (lamp) leads are<br />
pre-stripped 1/2".<br />
The two yellow 120v<br />
(output) and violet<br />
& grey (dimming<br />
control) leads have<br />
insulated ends.<br />
4-10<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
HID<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Contents<br />
General Information .................................................................5-2 to 5-3<br />
Core & Coil Ballast HID Replacement Kits..............................5-4 to 5-7<br />
EEI-NEMA Head <strong>Ballasts</strong>.....................................................................5-8<br />
Core & Coil Ballast HID Replacement Kits (Canada) ........................5-9<br />
Val-U-Pak Replacement Kits ............................................................5-10<br />
Val-U-Pak Plus Ballast/Lamp Replacement Kits .............................5-11<br />
Core & Coil <strong>Ballasts</strong> 71A Series (60 Hz)<br />
Mercury..........................................................................5-14 to 5-17<br />
Metal Halide ...................................................................5-18 to 5-31<br />
High Pressure Sodium ...................................................5-32 to 5-45<br />
Low Pressure Sodium....................................................5-46 to 5-47<br />
Capacitors for Bi-Level Operation ....................................................5-48<br />
Non-PCB Capacitors ............................................................5-48 to 5-49<br />
Ignitors & Ballast to Lamp Distances..................................5-50 to 5-53<br />
Transformers & Autotransformers ....................................................5-54<br />
Protected Dual-Volt F-Can 72C Series.................................5-55 to 5-58<br />
Mercury — Metal Halide — High Pressure Sodium<br />
Encapsulated Core & Coil 73B Series .................................5-59 to 5-62<br />
Mercury — Metal Halide — High Pressure Sodium<br />
Postline <strong>Ballasts</strong> 74P Series................................................5-63 to 5-66<br />
Mercury — Metal Halide — High Pressure Sodium<br />
Indoor Enclosed <strong>Ballasts</strong> 78E Series...................................5-67 to 5-68<br />
Mercury — Metal Halide — High Pressure Sodium<br />
Outdoor Weatherproof <strong>Ballasts</strong> 79W Series.......................5-69 to 5-71<br />
Mercury — Metal Halide — High Pressure Sodium<br />
Note:<br />
For International HID <strong>Ballasts</strong> (50Hz and 60Hz),<br />
See International <strong>Section</strong>, pages 6-14 to 6-19<br />
For <strong>Electronic</strong> HID <strong>Ballasts</strong>, See <strong>Section</strong> 4<br />
HID<br />
Corporate Offices<br />
(800) 322-2086<br />
Customer Support/Technical Service<br />
(800) 372-3331 • (+) 1 847 390-5000 (International)<br />
Visit our web site at www.advancetransformer.com<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 5-1
HIGH INTENSITY DISCHARGE BALLASTS<br />
ADVANCE ® HID Lamp <strong>Ballasts</strong> are available to operate the wide variety<br />
of mercury, metal halide, high pressure sodium and low pressure<br />
sodium lamps available in today’s marketplace.<br />
Like fluorescent, HID lamps are electric discharge lamps. Light is<br />
produced by an arc discharge between two electrodes located at<br />
opposite ends of an arc tube within the lamp’s outer glass envelope.<br />
The ballast is the lamp’s power supply; its purpose is to provide<br />
proper starting and operating voltage and current to initiate and sustain<br />
this arc.<br />
LAMP STARTING<br />
Mercury and Probe-Start Metal Halide Lamps<br />
Mercury and the “traditional” probe-start metal halide lamps (175<br />
through 1500 watt) have an additional electrode located at one end<br />
of the arc tube to assist in lamp starting. These types of lamps<br />
require an open circuit voltage (OCV) approximately two times the<br />
lamp’s operating voltage to initiate the arc.<br />
High Pressure Sodium and Pulse-Start Metal Halide Lamps<br />
High pressure sodium and modern metal halide lamps which include<br />
existing lamps, 150 watt and less, as well as the new generation of<br />
pulse-start metal halide lamps, 150 watt and greater, have no starting<br />
electrodes. In addition to an OCV of approximately two times the lamp<br />
voltage, these lamps utilize an “ignitor” to provide a high voltage<br />
starting pulse directly across the main electrodes. Once the lamp’s arc<br />
is established, the ignitor automatically stops delivering pulses, and<br />
the lamp comes up to full brightness on its own.<br />
Low Pressure Sodium<br />
Because they have neither a starting electrode nor an ignitor, low pressure<br />
sodium lamps require an open circuit voltage approximately three<br />
to seven times the lamp voltage to start and sustain the lamp.<br />
4-tap design is called a Quadri-Volt ® ballast and operates on either 120V,<br />
208V, 240V or 277V power. There is an <strong>Advance</strong> Quadri-Volt ® ballast for<br />
virtually every HID lamp on the market. New 5-TAP designs, which<br />
feature the same input voltages as Quadri-Volt ® ballasts plus 480V,<br />
are available for 250W, 400W, and 1000W metal halide and high<br />
pressure sodium applications.<br />
FIXTURE FUSING<br />
Many HID lighting fixtures are sold with protective fuses. The purpose<br />
of the fuse is to isolate a fixture from the lighting circuit in the event<br />
of excessive current draw, such as might be caused by a failed ballast.<br />
Unfortunately, the fuse will not protect the ballast from failure, as<br />
it is often the failed ballast itself that is causing the high current draw.<br />
With many fixtures the fuse is physically located in the ballast<br />
compartment of the fixture. The air temperature within this compartment<br />
can easily reach 80°C and still be within the design limitations<br />
of the fixture.<br />
Many fuses are temperature sensitive, meaning that the current rating<br />
goes down as the ambient temperature goes up. Fuse current ratings<br />
are based on the fuse’s performance in a 25°C ambient (77°F). In<br />
an 80°C ambient, some fuses will open at half their rating.<br />
As a result, the fuse rating shown in the HID ballast tables is calculated<br />
at 2 1 /2 to 3 times the highest current draw of the ballast: lamp operating,<br />
starting or open circuit conditions. Standard or slow-blow fuses<br />
should be used. Fast-blow fuses should be avoided as ballast in-rush<br />
currents during power turn-on could cause these fuses to blow<br />
unnecessarily. It is not necessary to use current limiting fuses.<br />
BALLAST DESIGN APPLICATIONS<br />
HID lamp ballasts are available in a variety of shapes and sizes for<br />
the most popular lighting applications. Six basic designs are in<br />
widest use today.<br />
HID<br />
LAMP OPERATION<br />
<strong>Electric</strong> discharge lamps have a negative resistance characteristic<br />
which causes them to draw an increasing amount of current leading<br />
to immediate destruction if operated directly from the power line.<br />
The ballast, therefore, is utilized to limit the current to the correct<br />
level for proper operation of the lamp.<br />
Ballast factor is defined as the ratio of light output produced by a<br />
lamp operating on a commercial ballast versus the lamp’s rated light<br />
output. <strong>Advance</strong> HID ballasts have a nominal ballast factor of 1.0,<br />
thus providing full light output.<br />
HID lamps take several minutes to warm-up and reach full lumen<br />
output. Additionally, an interruption in the input power or a sudden<br />
voltage drop may cause the arc to extinguish. A lamp that is hot will<br />
not restart immediately. Before the lamp will relight, it must cool sufficiently<br />
to reduce the vapor pressure within the arc tube to a point<br />
where the arc will restrike. The approximate warmup and restriking<br />
times of the HID lamp groups are as follows:<br />
LIGHT SOURCE WARM-UP TIME RESTRIKE TIME<br />
Mercury Vapor 5-7 minutes 3-6 minutes<br />
Metal Halide (Probe-Start) 3-4 minutes 10-20 minutes<br />
Metal Halide (Pulse-Start) 2 minutes 3-4 minutes<br />
High Pressure Sodium 3-4 minutes 1/2-1 minute<br />
Low Pressure Sodium 7-10 minutes 3-12 seconds<br />
BALLAST INPUT VOLTAGES<br />
Unlike fluorescent lighting which is operated on either 120 volt or<br />
277 volt circuits, power for HID lighting in the U.S. is delivered at any<br />
one of five voltages: 120V, 208V, 240V, 277V or 480V. While 120V<br />
and 277V are the most popular, because of the heavier loads and<br />
sometimes longer runs associated with HID lighting (such as shopping<br />
mall parking lots), 208V and 240V power is often used instead<br />
of 120V, and 480V instead of 277V.<br />
To address this multiplicity of voltages, the HID ballast industry offers<br />
ballasts with multiple input voltage taps on the primary coil. <strong>Advance</strong>'s<br />
Fluorescent Can<br />
(72C Series)<br />
Indoor Enclosed<br />
Rectangular Can<br />
(78E Series)<br />
Encapsulated Core & Coil<br />
(73B Series)<br />
Core & Coil<br />
The basic ballast is the open core & coil which is most often used as<br />
a component within a lighting fixture. The core & coil also forms the<br />
nucleus of the five other ballast configurations detailed in this section.<br />
It consists of either one, two or three copper coils on a core (or “stack”)<br />
of electrical-grade steel laminations. The coils are assembled to core<br />
sections which are then surface-welded together. At <strong>Advance</strong><br />
Transformer Co. the assembled ballast is vacuum impregnated with a<br />
silica-filled polyester varnish to re-enforce the electrical insulation, preclude<br />
moisture, inhibit noise, and dissipate heat. <strong>Advance</strong> utilizes a<br />
vacuum-pressure impregnation process. Most other HID ballast manufacturers<br />
apply varnish via a preheat-and-dip process which only puts a<br />
thin coat of varnish on the outer surface of the ballast. <strong>Advance</strong> Core &<br />
Coil ballasts feature as standard an insulation system rated class H<br />
(180°C maximum coil hot spot temp.) for ballasts below 600 watts, and<br />
ADVANCE Class N (200°C maximum coil hot spot temp.) for ballasts<br />
600 watts and higher. When performing in-fixture testing, the maximum<br />
allowable average coil temperature (measured by the rise-of-resistance<br />
method) is 165°C for class H ballasts or 185°C for ADVANCE Class N<br />
ballasts. The maximum allowable coil face or lead wire temperature<br />
(measured by thermocouple) is 150°C for both class H and ADVANCE<br />
Class N ballasts.<br />
5-2<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Encapsulated Core & Coil<br />
Where quiet performance is required, the standard open core & coil ballasts<br />
are encapsulated (potted) in a cube-shaped steel can utilizing<br />
Class H (180°C) polyester compound. These ballasts carry a Class A<br />
noise rating up through 175 watts and Class B for 250 and 400 watts.<br />
As with the open core & coil, the capacitor (and ignitor where included)<br />
are mounted separately within the fixture.<br />
<strong>Ballasts</strong> with Aluminum Secondary Coil<br />
<strong>Advance</strong> offers a wide range of ballasts that have primary coil made out<br />
of copper and secondary coil made out of aluminum. All <strong>Advance</strong> ballasts<br />
including ballasts with aluminum secondary coil adhere to ANSI<br />
specifications and are certified by respective agencies (UL, CSA, etc.).<br />
Aluminum ballasts are designated by -A after ballast Catalog number<br />
and/or “AL” on wiring diagram.<br />
Fluorescent Can (F-Can)<br />
For indoor commercial applications of HID lighting such as offices,<br />
schools and retail stores, ballast noise must be minimized. <strong>Ballasts</strong> for<br />
these fixtures are most often encased and potted in fluorescent ballast<br />
type cans and utilize Class A (90°C) asphalt insulating materials (the<br />
same as used in fluorescent lamp ballasts).<br />
The <strong>Advance</strong> line of F-can ballasts comes in two dual-voltage configurations:<br />
120/277 volt for the US market, and 120/347 volt for the<br />
Canadian market. Each unit has built-in, automatically resetting, thermal<br />
protectors which disconnect the ballast from the power line in the<br />
event of overheating. All units are high power factor and include the<br />
capacitor within the can. All models for high pressure sodium, lowwattage<br />
metal halide, and pulse-start metal halide lamps also include<br />
the ignitor in the can.<br />
Spacing between ballasts and the mounting surface must be considered<br />
when the ballasts are remote-mounted. Twelve inches between<br />
ballasts must be maintained and if multiple rows vertically are used,<br />
there should be at least 12 inches between rows. In addition to ballast<br />
and row spacing, the ballast must not be directly mounted to a nonmetallic<br />
surface. They must be spaced with mounting brackets (available<br />
from <strong>Advance</strong>) to allow airflow under the ballast base.<br />
Indoor Enclosed<br />
These units are designed for use indoors where the ballast must be<br />
mounted remotely from the luminaire. They are most typically used in<br />
factories where the luminaire may be mounted in a high-bay where very<br />
high ambient temperatures may be experienced. In these instances, the<br />
remotely-mounted ballast operates cooler, subsequently providing<br />
longer life because it is away from both the heat of the ceiling ambient<br />
and lamp heat within the fixture.<br />
The case contains the core & coil potted in a Class H (180°C) heatdissipating<br />
resin. The capacitor(s) and ignitor are contained within a<br />
separate compartment. Knockouts in both ends of the case facilitate<br />
hook-up in the most convenient manner. Wall mounting is accomplished<br />
through flanges on the top and bottom of the case. The ballast<br />
is a UL Listed product.<br />
Outdoor Weatherproof<br />
Weatherproof ballasts are designed for remote, pole-mounting outdoor<br />
applications under all weather conditions. They may also be placed inside<br />
of a transformer pole base, but care must be taken to avoid areas prone<br />
to flooding because weatherproof ballasts are not water-submersible.<br />
The core & coil with its capacitor and ignitor (where required) are<br />
firmly mounted to the heat-sink base. An aluminum cover is placed over<br />
the core-&-coil assembly and is bolted with a weather-tight gasket to<br />
the base. An integral 1" threaded nipple with locknut facilities hook-up<br />
to electrical conduit or to the mounting bracket when used on a pole.<br />
The weatherproof ballast may also be placed nipple-up, with a drip loop<br />
in the leads, inside a pole base.<br />
Postline<br />
Lantern-type fixtures mounted on slender poles often require ballasts<br />
which will fit into these poles. Special, elongated core & coil ballasts are<br />
potted in resin in cylindrical cans having a 2.55” outside diameter. All<br />
include leads necessary for direct connection to a photocell.<br />
The capacitor and ignitor (where required) are included within this<br />
can. A ¹₂" threaded nipple is used for vertical mounting, and leads<br />
extend from both ends of the can for ease of installation. The input<br />
leads to the ballast also provide for proper connection to the photocell<br />
if such is included within the fixture.<br />
To help prevent overheating, one to three feet of air space should be<br />
allowed in the pole above the ballast, and the ballast should be positioned<br />
against the post interior wall to provide a heat-sink. All units<br />
rated 100W and above now include a mounting kit consisting of an 18"<br />
chain to hang the ballast within the pole and a spring clip to force the<br />
ballast's cylindrical can to make line contact with the pole's interior<br />
surface to maximize heat transfer, thus prolonging the ballast life.<br />
BALLAST DATE AND TEMPERATURE CODES<br />
Ballast Label<br />
Catalog Number<br />
Alternate Positions for<br />
Date Stamp Code<br />
Temperature<br />
Code<br />
Date Code<br />
Stamp<br />
ADVANCE ® HID Core & Coil ballasts are date stamped on either the top<br />
surface or the side surface of the ballast core. The four-digit number represents<br />
the week and year of manufacture. The first two numbers indicate<br />
the week and the last two indicate the year the ballast was manufactured.<br />
The example shows a ballast manufactured during the 36th<br />
week of 1989. The three letters are an <strong>Advance</strong> factory code.<br />
The ballast’s UL Bench Top Rise Temperature Code is shown on the label<br />
(see below).<br />
UL BENCH TOP RISE TEMPERATURE CODE<br />
To facilitate UL inspection, each ballast’s UL Bench Top Rise<br />
Temperature Code is shown on the <strong>Advance</strong> Core & Coil ballast label as<br />
1029X, where 1029 is the UL Standard for HID <strong>Ballasts</strong>, and the X is the<br />
temperature code: A, B, C, etc. If a fixture is UL listed for 1029C, then<br />
automatically, all ballasts with an A, B, or C temperature classification<br />
are acceptable for use within that same fixture.<br />
UL Bench Top Rise<br />
Letter Code<br />
A<br />
B<br />
C<br />
D<br />
E<br />
F<br />
etc.<br />
Temperature Range for<br />
Class H (180°C) <strong>Ballasts</strong><br />
less than 75°C<br />
75°C < 80°C<br />
80°C < 85°C<br />
85°C < 90°C<br />
90°C < 95°C<br />
95°C < 100°C<br />
etc.<br />
Temperature Range for<br />
Class N (200°C) <strong>Ballasts</strong><br />
less than 95°C<br />
95°C < 100°C<br />
100°C < 105°C<br />
105°C < 110°C<br />
110°C < 115°C<br />
115°C < 120°C<br />
etc.<br />
CERTIFICATIONS____________________________________<br />
Indicates ballast is listed by Underwriters Laboratories,<br />
Inc. in accordance with UL 1029 Standard for HID <strong>Ballasts</strong>.<br />
Each ballast is marked appropriately.<br />
Indicates ballast is component recognized by Underwriters<br />
Laboratories, Inc. in accordance with UL 1029 Standard for<br />
HID <strong>Ballasts</strong>. Each ballast is marked appropriately.<br />
Indicates ballast is certified by Canadian Standards<br />
Association in accordance with CAN/CSA-22.2 No. 74-<br />
92.Each ballast is marked appropriately.<br />
All HID <strong>Ballasts</strong> are designed and manufactured in<br />
accordance with the American National Standards<br />
Institute Standard for HID <strong>Ballasts</strong>, ANSI C82.4.<br />
HID<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 5-3
HID<br />
HID<br />
Core & Coil Replacement Kits<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Distributor Kits and Replacement Ignitors<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
<strong>Advance</strong> furnishes 120/208/240/277 Quadri-Volt ® core & coil ballasts to allow the stocking distributor to conveniently meet the<br />
replacement and retrofit needs of customers. In addition, <strong>Advance</strong> now offers 120/208/240/277/480 volt 5-TAP core & coil ballasts for<br />
the most popular applications. 5-TAP ballasts add the 480 volt input lead to the Quadri-volt designs. A Quadri-Volt or 5-TAP core &<br />
coil, along with the appropriate capacitor, ignitor (where required), mounting bracket & hardware and installation instructions are packed<br />
in a space-saving shipping carton. These “kits” eliminate the need for distributors or end-users to stock loose components of single<br />
voltage ballasts for 120, 208, 240, 277, and even some 480 volt applications, though single voltage kits for 480 volt applications will also<br />
be available.<br />
Ignitors are also packaged in individual cartons for replacement needs. There are several different ignitors to meet the needs of the<br />
many different lamps. The appropriate ignitor for each ballast is shown in the far right column on the page in this <strong>Atlas</strong> where the ballast<br />
is listed. Additionally, this information is summarized in the tables on pages 5-50 through 5-53.<br />
Pre-wired<br />
Ignitor!<br />
Dry Capacitor<br />
Now Rated 105°C !<br />
Pre-attached<br />
Connectors for<br />
Capacitor!<br />
Dry Capacitors<br />
We have extended the operating voltage range of our dry capacitors from 330 to 400 volts. This<br />
means that our most popular HID replacement kits for 175, 250, and 400-watt metal halide lamps now<br />
contain dry capacitors and offer the additional benefits available only with a dry capacitor.<br />
HID<br />
Those benefits are:<br />
• Dry capacitors are typically 25 to 50% smaller than their oil-filled<br />
counterparts, assuring that the <strong>Advance</strong> ballast kit will fit existing fixtures.<br />
• Dry capacitors are rated 105°C, 15°C higher than 90°C oil-filled capacitors, thus assuring longer<br />
component life.<br />
• Dry capacitors are built using a thermoplastic case, thus eliminating the need for grounding and<br />
insuring a faster, easier replacement.<br />
• Unlike oil-filled capacitors with exposed tab terminals, dry capacitors have no exposed live parts and<br />
thus protect end-users from hazardous voltages.<br />
• For customers who prefer connecting dry capacitors via flag terminals (like oil-filled capacitors are<br />
attached) a new line of dry capacitors with terminals is available. See page 5-48 for a full line of offerings.<br />
The bottom line is that our expanded use of dry capacitors makes the contractor’s job faster and<br />
easier. Look for the “D” at the end of our catalog number, it identifies the ballast kit as one that<br />
contains a dry capacitor!<br />
oil<br />
cap<br />
end comparison<br />
Capacitor Size Comparison<br />
Oil-Filled vs. <strong>Advance</strong> Dry Type<br />
5/8" required clearance for terminals<br />
oil cap<br />
dry<br />
cap<br />
side-by-side comparison<br />
dry<br />
cap<br />
HID<br />
REPLACEMENT KITS<br />
Kit Options<br />
HID Replacement<br />
Ballast Kit<br />
Pages<br />
Includes Core & Coil, Capacitor,<br />
Ignitor (where required), and<br />
Complete Mounting Hardware<br />
for ALL Components<br />
Includes 5-TAP<br />
Ballast Where<br />
Available<br />
Carton Has Space<br />
for A Distributor-<br />
Supplied Lamp<br />
Premium-Grade<br />
Clear Lamp<br />
Included<br />
Easy-Carry Handle<br />
On Carton<br />
71A (standard) 5-5,6,7,8,9<br />
✓ ✓<br />
77K (Val-U-Pak) 5-10<br />
✓ ✓<br />
✓<br />
77L (Val-U-Pak PLUS)<br />
5-11 ✓<br />
✓ ✓<br />
✓<br />
5-4<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil Replacement Kits<br />
HID<br />
METAL HALIDE<br />
New<br />
New<br />
Input<br />
Volts<br />
70 Watt Lamp, ANSI Code M98<br />
120/208/<br />
240/277<br />
71A5292-001D HX-HPF 5.2 ✓ ✓<br />
100 Watt Lamp, ANSI Code M90/M140<br />
120/208/<br />
240/277<br />
71A5390-001D HX-HPF 6.0 ✓ ✓<br />
150 Watt Lamp, ANSI Code M102/M142<br />
120/208/<br />
240/277<br />
71A5492-001D HX-HPF 7.75 ✓ ✓<br />
175/150 Watt Lamp, ANSI Code M57/M107 or H39<br />
120/208/<br />
240/277<br />
71A5570-001D CWA 8.5 ✓ ✓<br />
480 71A5540-001D CWA 8.5 ✓ ✓<br />
175 Watt Lamp, ANSI Code M137/M152<br />
120/208/<br />
240/277<br />
71A5593-001D CWA 10.0 ✓ ✓<br />
200 Watt Lamp, ANSI Code M136<br />
Linear<br />
277 71A5637-001D* 6.0<br />
Reactor HPF<br />
250 Watt Lamp, ANSI Code M58 or H37<br />
120/208/<br />
240/277<br />
120/208/<br />
240/277<br />
Super<br />
71A5692-001D 8.0 ✓ ✓<br />
CWA<br />
71A5770-001D<br />
CWA<br />
4 1 /4 x 4 3 /4<br />
71A5750-001D Core 10.0 ✓ ✓<br />
71A5771-001D<br />
CWA<br />
3x4<br />
Core<br />
Includes -540 bracket. See drawing below for details.<br />
*<br />
CORE & COIL MOUNTING BRACKETS<br />
Included with all Replacement Kits<br />
(See Page 5-6 for addional bracket diagram)<br />
13.0<br />
480 71A5740-001D 12.0<br />
11.0<br />
480 71A5741-001D 10.0<br />
250 Watt Lamp, ANSI Code M138<br />
Linear<br />
277 71A5737-001D<br />
Reactor HPF<br />
120/208/<br />
240/277<br />
Catalog<br />
Number<br />
71A5792-001D<br />
Circuit<br />
Type<br />
50 Watt Lamp, ANSI Code M110/M148<br />
Super<br />
CWA<br />
Total Certifications<br />
Weight<br />
(Lbs)<br />
120/277 71A5181-001D HX-HPF 4.9 ✓ ✓<br />
120/208/<br />
240/277<br />
120/208/<br />
240/277/<br />
480<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
Includes welded-on angle<br />
bracket (-540 option)<br />
standard with -001D kit.<br />
Allows Linear Reactor ballast<br />
to mount in fixtures designed<br />
for standard CWA ballasts<br />
without the need for<br />
additional brackets.<br />
✓<br />
✓<br />
✓<br />
✓<br />
7.0 ✓ ✓<br />
9.0 ✓ ✓<br />
New<br />
METAL HALIDE<br />
320 Watt Lamp, ANSI Code M132<br />
Linear<br />
277 71A5837-001D*<br />
Reactor HPF<br />
120/208/<br />
Super<br />
71A5892-001D<br />
240/277<br />
CWA<br />
350 Watt Lamp, ANSI Code M131<br />
277 71A5937-001D*<br />
Linear<br />
Reactor HPF<br />
10.0 ✓<br />
120/208/<br />
Super<br />
71A5993-001D<br />
240/277<br />
CWA<br />
11.0 ✓ ✓<br />
400 Watt Lamp, ANSI Code M59 or H33<br />
277 71A6037-001D*<br />
Linear<br />
Reactor HPF<br />
9.0 ✓<br />
120/208/<br />
240/277<br />
71A6071-001D CWA 11.5 ✓ ✓<br />
120/208/<br />
240/277/ 71A6051-001D CWA 14.0 ✓ ✓<br />
480<br />
480 71A6041-001D CWA 12.0 ✓ ✓<br />
400 Watt Lamp, ANSI Code M135<br />
277 71A6137-001D*<br />
Linear<br />
9.0 ✓<br />
750 Watt Lamp, ANSI Code M149<br />
277/347/<br />
480<br />
71A64F2-001D CWA 18.7 ✓ ✓<br />
1000 Watt Lamp, ANSI Code M47 or H36<br />
120/208/<br />
240/277<br />
71A6572-001 CWA 28.0 ✓ ✓<br />
120/208/<br />
240/277/ 71A6552-001 CWA 22.0 ✓ ✓<br />
480<br />
480 71A6542-001 CWA 28.0 ✓ ✓<br />
1500 Watt Lamp, ANSI Code M48<br />
120/208/<br />
240/277<br />
71A6772-001 CWA 31.0 ✓ ✓<br />
480 71A6742-001 CWA 31.0 ✓ ✓<br />
Includes -540 bracket. See drawing below for details.<br />
*<br />
Input<br />
Volts<br />
9.5 ✓<br />
11.0 ✓ ✓<br />
480-T 71A5842-001DT SCWA 12.8 ✓ ✓<br />
120/208/<br />
240/277<br />
71A6092-001D<br />
Reactor HPF<br />
Super<br />
CWA<br />
Two 400 Watt Lamps, ANSI Code M59 or H33<br />
120/277 71A6382-001D<br />
CWA<br />
Independent 31.0<br />
480 71A6342-001D<br />
Lamp<br />
Operation 31.0<br />
450 Watt Lamp, ANSI Code M144<br />
Linear<br />
277 71A6337-001D<br />
Reactor HPF<br />
120/208/<br />
240/277<br />
Catalog<br />
Number<br />
71A6393-001D<br />
Circuit<br />
Type<br />
Super<br />
CWA<br />
Total Certifications<br />
Weight<br />
(Lbs)<br />
11.0 ✓ ✓<br />
9.0<br />
11.0<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
HID<br />
REPLACEMENT KITS<br />
-540 Bracket Detail<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-5
HID-CORE & COIL BALLAST REPLACEMENT KITS<br />
HID<br />
REPLACEMENT KITS<br />
New<br />
New<br />
New<br />
New<br />
New<br />
HIGH PRESSURE SODIUM<br />
"B" Suffix Denotes Integral Ignitor<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Circuit<br />
Type<br />
Total<br />
Weight<br />
(Lbs)<br />
Certifications<br />
35 Watt Lamp, ANSI Code S76<br />
120 71A7707-001DB R-HPF 1.5 ✓ ✓<br />
50 Watt Lamp, ANSI Code S68<br />
120 71A7807-001DB R-HPF 1.9 ✓ ✓<br />
120/277 71A7801-001D HX-HPF 3.5 ✓ ✓<br />
70 Watt Lamp, ANSI Code S62<br />
120 71A7907-001DB R-HPF 2.5 ✓ ✓<br />
120/208/<br />
240/277<br />
71A7971-001D HX-HPF 5.5 ✓ ✓<br />
120/208/<br />
240/277<br />
71A7991-001DC HX-HPF 5.5 ✓ ✓<br />
100 Watt Lamp, ANSI Code S54<br />
120 71A8007-001DB R-HPF 3.1 ✓ ✓<br />
120/208/<br />
240/277<br />
71A8071-001D HX-HPF 7.3 ✓ ✓<br />
120/208/<br />
240/277<br />
71A8091-001DC HX-HPF 7.3 ✓ ✓<br />
480 71A8041-001D HX-HPF 7.0 ✓ ✓<br />
150 Watt Lamp, ANSI Code S55<br />
120 71A8107-001DB R-HPF 4.0 ✓ ✓<br />
120/208/<br />
240/277<br />
71A8172-001D HX-HPF 8.0 ✓ ✓<br />
120/208/<br />
240/277<br />
71A8192-001DC HX-HPF 8.0 ✓ ✓<br />
480 71A8142-001D HX-HPF 9.5 ✓ ✓<br />
150 Watt Lamp, ANSI Code S56<br />
120/208/<br />
240/277<br />
71A8176-001D CWA 8.5 ✓ ✓<br />
480 71A8146-001D CWA 8.5 ✓ ✓<br />
CORE & COIL MOUNTING BRACKETS<br />
Included with Replacement Kits<br />
HPS Kit Options<br />
In addition to the standard kits, this and the following page<br />
include two HPS kits with special features:<br />
HPS Reactor Kits with Integral Ignitors<br />
“B” Suffix (p.5-6) denotes 120V reactor circuit kits featuring singlecoil<br />
reactor ballasts with integral ignitors. The kit includes a mounting<br />
bracket (PC848S) sized specifically for the small reactor ballasts.<br />
Compact<br />
Reactor Core<br />
and Bracket<br />
HPS Kits with Plug-In Ignitors<br />
“C” Suffix (p.5-7) denotes standard HPS kit except with plug-in<br />
ignitor. A mating receptacle is attached to the core and coil lead wires,<br />
ready for immediate connection.<br />
Connectorized<br />
ignitor and<br />
mating<br />
receptable<br />
PC-8485<br />
PC-848S mounting bracket for Figure 9<br />
C0re & Coil ballasts. Bracket and thrubolts<br />
are included in 120V HPS Reactor<br />
Kits.<br />
Bracket<br />
Mounting<br />
Holes<br />
7⁷⁄₁₆"<br />
4³⁄₈"<br />
Ballast<br />
Mounting<br />
Holes<br />
³⁄₄"<br />
PC-849 Mounting<br />
bracket for Fig.2, 3, 8, 8a &10<br />
Core & Coil <strong>Ballasts</strong>.<br />
To order individual packaged<br />
kits, specify PKG 849-2<br />
(2 brackets with thru bolts).<br />
4¹⁄₄"<br />
Spacing<br />
in fixture<br />
power door<br />
3⁷⁄₈"<br />
8"<br />
PC-909 Mounting<br />
bracket for Fig. 2, 3 & 8<br />
Core & Coil <strong>Ballasts</strong><br />
when used with power-door<br />
roadway fixtures.<br />
5-6<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HID-CORE & COIL BALLAST REPLACEMENT KITS<br />
New<br />
New<br />
New<br />
HIGH PRESSURE SODIUM<br />
“C” Suffix Denotes Plug-In Ignitor<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Circuit<br />
Type<br />
Total<br />
Weight<br />
(Lbs)<br />
Certifications<br />
200 Watt Lamp, ANSI Code S66<br />
120/208/<br />
240/277<br />
71A8970-001D CWA 8.5 ✓ ✓<br />
480 71A8940-001D CWA 8.5 ✓ ✓<br />
250 Watt Lamp, ANSI Code S50<br />
120/208/<br />
240/277<br />
71A8271-001D CWA 11.5 ✓ ✓<br />
120/208/<br />
240/277/ 71A8251-001D CWA 12.0 ✓ ✓<br />
480<br />
120/208/<br />
240/277<br />
71A8291-001DC CWA 11.5 ✓ ✓<br />
480 71A8241-001D CWA 11.0 ✓ ✓<br />
310 Watt Lamp, ANSI Code S67<br />
120/208/<br />
240/277<br />
71A8371-001D CWA 13.8 ✓ ✓<br />
400 Watt Lamp, ANSI Code S51<br />
120/208/<br />
240/277<br />
71A8473-001D CWA 15.0 ✓ ✓<br />
120/208/<br />
240/277/ 71A8453-001D CWA 16.0 ✓ ✓<br />
480<br />
120/208/<br />
240/277<br />
71A8493-001DC CWA 15.0 ✓ ✓<br />
480 71A8443-001D CWA 15.5 ✓ ✓<br />
480 71A8443-001DC CWA 15.5 ✓ ✓<br />
1000 Watt Lamp, ANSI Code S52<br />
120/208/<br />
240/277<br />
71A8773-001 CWA 31.0 ✓ ✓<br />
120/208/<br />
240/277/ 71A8753-001 CWA 29.0 ✓ ✓<br />
480<br />
120/208/<br />
240/277<br />
71A8793-001C CWA 31.0 ✓ ✓<br />
480 71A8743-001 CWA 31.0 ✓ ✓<br />
480 71A8743-001C CWA 31.0 ✓ ✓<br />
New<br />
New<br />
MERCURY<br />
Input<br />
Volts<br />
50 Watt Lamp, ANSI Code H46<br />
120 71A1800-001 HX-NPF 3.3<br />
100 Watt Lamp, ANSI Code H38 or H44<br />
120/208/<br />
71A2571-001D CWA 5.0<br />
240/277<br />
120 71A2800-001 HX-NPF 3.8<br />
175 Watt Lamp, ANSI Code H39<br />
120/208/<br />
240/277<br />
71A3072-001D CWA 6.5 ✓ ✓<br />
480 71A3042-001D CWA 5.0 ✓ ✓<br />
120 71A3301-001 HX-NPF 5.0 ✓ ✓<br />
250 Watt Lamp, ANSI Code H37<br />
120/208/<br />
240/277<br />
71A3572-001D CWA 8.3 ✓ ✓<br />
480 71A3542-001D CWA 7.5 ✓ ✓<br />
400 Watt Lamp, ANSI Code H33<br />
120/208/<br />
240/277<br />
71A4071-001D CWA 12.5 ✓ ✓<br />
480 71A4041-001D CWA 12.0 ✓ ✓<br />
Two 400 Watt Lamps, ANSI Code H33<br />
120 71A4300-001 CWI<br />
277 71A4330-001 (2 lamps 20.3 ✓ ✓<br />
480 71A4340-001 in series)<br />
1000 Watt Lamp, ANSI Code H36<br />
120/208/<br />
240/277<br />
71A5070-001 CWA 24.3 ✓ ✓<br />
480 71A5040-001 CWA 23.0 ✓ ✓<br />
LOW PRESSURE SODIUM<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Catalog<br />
Number<br />
Circuit<br />
Type<br />
Circuit<br />
Type<br />
Total Certifications<br />
Weight<br />
(Lbs)<br />
Total<br />
Weight<br />
(Lbs)<br />
Certifications<br />
35 or 55 Watt Lamp, ANSI Code L70 or L71<br />
120/208/<br />
71A0490-001D HX-PFC 7.5 ✓ ✓<br />
240/277<br />
90 WATT LAMP, ANSI CODE L72<br />
120/208/<br />
71A0590-001D HX-HPF 11.0 ✓ ✓<br />
240/277<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
HID<br />
REPLACEMENT KITS<br />
CORE & COIL MOUNTING BRACKETS<br />
Included with Replacement Kits<br />
New<br />
135 or 180 Watt Lamp, ANSI Code L73 or L74<br />
120/208/<br />
71A0790-001D HX-HPF 17.5 ✓ ✓<br />
240/277<br />
Bracket<br />
Mounting<br />
Holes<br />
7⁷⁄₁₆"<br />
4³⁄₈"<br />
Ballast<br />
Mounting<br />
Holes<br />
³⁄₄"<br />
4¹⁄₄"<br />
Spacing<br />
in fixture<br />
power door<br />
3⁷⁄₈"<br />
8"<br />
PC-909 Mounting<br />
bracket for Fig. 2, 3 & 8<br />
Core & Coil <strong>Ballasts</strong><br />
when used with power-door<br />
roadway fixtures.<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 5-7
HID-EEI NEMA HEAD BALLAST ASSEMBLIES<br />
Input<br />
Volts<br />
Catalog Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Dimensions<br />
Fig A B<br />
Net<br />
Wt<br />
(Ibs)<br />
MERCURY<br />
175 Watt Lamp, ANSI Code H39<br />
120 71A3304-791 HX-NPF 205 3.00<br />
A 1.00 2.3 6.0<br />
240<br />
240 71A3325-791 R-NPF 195 2.70 B 1.75 3.0 5.0<br />
250 Watt Lamp, ANSI Code H37<br />
120 71A3801-791 HX-NPF 285 4.80 240 A 1.65 2.3 7.5<br />
HIGH PRESSURE SODIUM<br />
70 Watt Lamp, ANSI Code S62<br />
120 71A7907-791 R-NPF 86 2.10 120 B 1.50 3.0 3.8<br />
100 Watt Lamp, ANSI Code S54<br />
120 71A8007-791 R-NPF 115 3.05 120 B 1.50 3.0 4.3<br />
150 Watt Lamp, ANSI Code S55<br />
120 71A8107-791 R-NPF 170 4.50 120 B 2.00 3.6 5.3<br />
Note: All NEMA Head ballasts include an ignitor integral to the core & coil. All are NPF and<br />
do not include a capacitor.<br />
HID-EEI<br />
NEMA HEAD<br />
2⁵⁄₈"<br />
MOGUL<br />
SOCKET<br />
MOGUL<br />
SOCKET<br />
8" IGNITOR<br />
3⁵⁄₈"<br />
NOTE: Ignitor<br />
for High<br />
Pressure<br />
Sodium Only<br />
8"<br />
3¹⁄₂"<br />
A<br />
B MAX<br />
1³⁄₄"<br />
A<br />
BALLAST<br />
B-ACROSS COIL<br />
Note: Integral<br />
ignitor included<br />
in ballast<br />
3¹⁵⁄₃₂"<br />
4³⁄₈" 5"<br />
2⁵⁄₈"<br />
4³⁄₈"<br />
5"<br />
Fig. A<br />
Fig. B<br />
5-8<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HID-CORE & COIL REPLACEMENT KITS<br />
MERCURY<br />
FOR CANADA<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Circuit<br />
Type<br />
Total Certifications<br />
Weight<br />
(Lbs)<br />
METAL HALIDE<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Circuit<br />
Type<br />
Total<br />
Weight<br />
(Lbs)<br />
70 Watt Lamp, ANSI Code M98<br />
120/<br />
71A52A2-001D HX-HPF 5.0<br />
277/347<br />
100 Watt Lamp, ANSI Code M90<br />
120/<br />
71A53A0-001D HX-HPF 5.5<br />
277/347<br />
Certifications<br />
175/150 Watt Lamp, ANSI Code M57/M107 or H39<br />
120/<br />
71A55A0-001D CWA 7.0 ✓ ✓<br />
277/347<br />
250 Watt Lamp, ANSI Code M58 or H37<br />
120/<br />
71A57A0-001D CWA 10.0<br />
277/347<br />
400 Watt Lamp, ANSI Code M59 or H33<br />
120/<br />
71A60A1-001D CWA 12.0<br />
277/347<br />
1000 Watt Lamp, ANSI Code M47 or H36<br />
120/<br />
71A65A2-001 CWA 21.0<br />
277/347<br />
1500 Watt Lamp, ANSI Code M48<br />
120/<br />
71A67A2-001 CWA 30.0<br />
277/347<br />
Note:<br />
175, 250, and 400-watt metal halide<br />
kits now include dry capacitors!<br />
(see page 5-5 for a full explanation of<br />
the features and benefits of dry capacitors)<br />
CORE & COIL MOUNTING BRACKETS<br />
Included with Replacement Kits<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
NEW<br />
100 Watt Lamp, ANSI Code H38 or H44<br />
120/<br />
71A25A1-001D CWA 5.0<br />
277/347<br />
125 Watt Lamp, ANSI Code H42<br />
120/<br />
71A29D1-001D CWA 5.0<br />
240/347<br />
175 Watt Lamp, ANSI Code H39<br />
120/<br />
71A30D2-001D CWA 5.5<br />
240/347<br />
250 Watt Lamp, ANSI Code H37<br />
120/<br />
71A35D2-001D CWA 7.5<br />
240/347<br />
400 Watt Lamp, ANSI Code H33<br />
120/<br />
71A40D1-001D CWA 10.5<br />
240/347<br />
HIGH PRESSURE SODIUM<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Circuit<br />
Type<br />
Total<br />
Weight<br />
(Lbs)<br />
70 Watt Lamp, ANSI Code S62<br />
120/<br />
71A79A1-001D HX-HPF 5.5<br />
277/347<br />
100 Watt Lamp, ANSI Code S54<br />
120/<br />
71A80A1-001D HX-HPF 7.5<br />
277/347<br />
150 Watt Lamp, ANSI Code S55<br />
120/<br />
71A81A2-001D HX-HPF 8.0<br />
277/347<br />
250 Watt Lamp, ANSI Code S50<br />
120/<br />
71A82A1-001D CWA 11.5<br />
277/347<br />
400 Watt Lamp, ANSI Code S51<br />
120/<br />
71A84A3-001D CWA 15.0<br />
277/347<br />
1000 Watt Lamp, ANSI Code S52<br />
120/<br />
71A87A3-001 CWA 31.0<br />
277/347<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
Certifications<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
HID REPLACEMENT<br />
KITS<br />
Bracket<br />
Mounting<br />
Holes<br />
7⁷⁄₁₆"<br />
4³⁄₈"<br />
Ballast<br />
Mounting<br />
Holes<br />
³⁄₄"<br />
3⁷⁄₈"<br />
PC-849 Mounting<br />
bracket for Fig.2, 3, 8, 8a &10<br />
Core & Coil <strong>Ballasts</strong>.<br />
To order individual packaged<br />
kits, specify PKG 849-2<br />
(2 brackets with thru bolts).<br />
4¹⁄₄"<br />
Spacing<br />
in fixture<br />
power door<br />
8"<br />
PC-909 Mounting<br />
bracket for Fig. 2, 3 & 8<br />
Core & Coil <strong>Ballasts</strong><br />
when used with power-door<br />
roadway fixtures.<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 5-9
HID VAL-U-PAK REPLACEMENT KITS<br />
Val-U-Pak replacement kits combine all of the features and<br />
components of our popular HID Replacement Kits into a<br />
new, easy-to-carry carton. In addition, these cartons contain<br />
space to add the lamp of YOUR choosing. Need an open-fixture<br />
rated lamp? Coated lamp? Compact or medium base<br />
lamp? Meet your customer’s specific lamp requirement and<br />
package it with the appropriate <strong>Advance</strong> ballast to better<br />
serve the needs of your contractor and MRO clients!<br />
HID VAL-U-PAK<br />
REPLACEMENT KITS<br />
The <strong>Advance</strong> VAL-U-PAK makes total fixture changeouts<br />
easier - packaging labor-saving convenience in an<br />
easy-to-carry carton.<br />
VAL-U-PAK ® features:<br />
• Convenience - Quadri-Volt core and coil ballast with all<br />
required components and mounting hardware packed together<br />
• Easy Handling - Sturdy handles and heavy duty packaging<br />
• Added Safety - Dry film capacitors<br />
• Quick and Accurate Install with No Live Parts - Ignitors are<br />
all pre-wired in High Pressure Sodium and Pulse-start Metal<br />
Halide Kits, eliminating common wiring errors<br />
• Flexibility - Space to add the lamp YOU choose<br />
HID VAL-U-PAKs are available with<br />
the 11 most popular ADVANCE HID<br />
ballast replacement kits:<br />
HIGH PRESSURE SODIUM<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Circuit<br />
Type<br />
Total<br />
Weight<br />
(Lbs)<br />
100 Watt Lamp, ANSI Code S54<br />
120/208/<br />
77K8071-001D HX-HPF 7.3<br />
240/277<br />
150 Watt Lamp, ANSI Code S55<br />
120/208/<br />
77K8172-001D HX-HPF 8.0<br />
240/277<br />
250 Watt Lamp, ANSI Code S50<br />
120/208/<br />
77K8271-001D CWA 11.5<br />
240/277<br />
400 Watt Lamp, ANSI Code S51<br />
120/208/<br />
77K8473-001D CWA 15.0<br />
240/277<br />
Certifications<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
PULSE-START METAL HALIDE<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
320 Watt Lamp, ANSI Code M132<br />
Linear<br />
277 77K5837-001D*<br />
Reactor HPF<br />
120/208/<br />
Super<br />
77K5892-001D<br />
240/277<br />
CWA<br />
350 Watt Lamp, ANSI Code M131<br />
Linear<br />
277 77K5937-001D*<br />
Reactor HPF<br />
120/208/<br />
77K5993-001D<br />
240/277<br />
* includes -540 Bracket<br />
METAL HALIDE<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Circuit<br />
Type<br />
Super<br />
CWA<br />
Circuit<br />
Type<br />
Total<br />
Weight<br />
(Lbs)<br />
9.5 ✓<br />
11.0 ✓ ✓<br />
10.0 ✓<br />
Certifications<br />
11.0 ✓ ✓<br />
Total<br />
Weight<br />
(Lbs)<br />
Certifications<br />
175/150 Watt Lamp, ANSI Code M57/M107 or H39<br />
120/208/<br />
77K5570-001D CWA 8.5 ✓ ✓<br />
240/277<br />
250 Watt Lamp, ANSI Code M58 or H37<br />
120/208/<br />
240/277<br />
77K5770-001D<br />
CWA<br />
4¹⁄₄ x 4³⁄₄<br />
Core<br />
Space for<br />
Distributor<br />
Supplied Lamp<br />
13.0 ✓ ✓<br />
400 Watt Lamp, ANSI Code M59 or H33<br />
120/208/<br />
77K6071-001D CWA 11.5 ✓ ✓<br />
240/277<br />
5-10<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HID VAL-U-PAK PLUS REPLACEMENT KITS<br />
NEW<br />
When standard lamps are all that is needed...<br />
Val-U-Pak Plus Kits feature all of the benefits of<br />
the Val-U-Pak Kits PLUS a whole lot more:<br />
New<br />
New<br />
New<br />
New<br />
Additional Features of Val-U-Pak Plus:<br />
• Added Versatility – 5-Tap core and coil ballast<br />
for the six most popular applications<br />
*Adds the 480V input lead to the Quadri-Volt<br />
*design<br />
• All Inclusive – Premium grade clear lamp<br />
supplied in kit<br />
*Manufactured by major lamp company and<br />
*warranteed by <strong>Advance</strong><br />
• Higher Wattage Options – <strong>Advance</strong> Class N<br />
(200°C) insulation system on 1000W units<br />
provides an additional 20°C margin for high<br />
ambient applications<br />
HID VAL-U-PAKs Plus kits are available for the 9 most popular applications<br />
METAL HALIDE<br />
HIGH PRESSURE SODIUM<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Circuit<br />
Type<br />
Total<br />
Weight<br />
(Lbs)<br />
Certifications<br />
175/150 Watt Lamp, ANSI Code M57/M107 or H39<br />
120/208/<br />
77L5570-001D CWA 9.5 ✓ ✓<br />
240/277<br />
250 Watt Lamp, ANSI Code M58 or H37<br />
120/208/<br />
240/277/ 77L5750-001D CWA 14.0 ✓ ✓<br />
480<br />
400 Watt Lamp, ANSI Code M59 or H33<br />
120/208/<br />
240/277/ 77L6051-001D CWA 17.0 ✓ ✓<br />
480<br />
1000 Watt Lamp, ANSI Code M47 or H36<br />
120/208/<br />
240/277/<br />
480<br />
77L6552-001 CWA 29.0 ✓ ✓<br />
New<br />
New<br />
New<br />
New<br />
New<br />
HID installations just got simpler, more convenient - and up to<br />
30% faster, with the new Val-U-Pak Plus kits from <strong>Advance</strong>.<br />
Why Should You Change All the Components?<br />
HID fixtures are generally difficult to reach and to service.<br />
Subsequently, the cost of labor can often exceed the cost of the<br />
ballast and/or lamp. When the ballast, capacitor or ignitor reach<br />
end-of-life, it is recommended that all of these components in the<br />
fixture be replaced at the same time. It is equally suggested that<br />
the lamp also be replaced, assuring optimal performance of the<br />
system and eliminating the need to re-service the fixture during<br />
the entire life-cycle of the lamp.<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Circuit<br />
Type<br />
Total<br />
Weight<br />
(Lbs)<br />
100 Watt Lamp, ANSI Code S54<br />
120/208/<br />
77L8071-001D-MED CWA 8.5<br />
240/277<br />
150 Watt Lamp, ANSI Code S55<br />
120/208/<br />
77L8172-001D-MOG CWA 9.5<br />
240/277<br />
Certifications<br />
250 Watt Lamp, ANSI Code S50<br />
120/208/<br />
240/277/ 77L8251-001D CWA 15.0 ✓ ✓<br />
480<br />
400 Watt Lamp, ANSI Code S51<br />
120/208/<br />
240/277/<br />
480<br />
77L8453-001D CWA 16.0 ✓ ✓<br />
1000 Watt Lamp, ANSI Code S52<br />
120/208/<br />
240/277/ 77L8753-001 CWA 31.0 ✓ ✓<br />
480<br />
✓<br />
✓<br />
✓<br />
✓<br />
HID VAL-U-PAK PLUS<br />
REPLACEMENT KITS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 5-11
HIGH INTENSITY DISCHARGE BALLASTS<br />
NOTES<br />
HID<br />
5-12<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
ORDERING INFORMATION<br />
How to Order<br />
<strong>Advance</strong> Transformer has developed the industry’s broadest selection of HID ballasts. More than 3000 stocking distributors<br />
nationwide. For information on the distributor best able to serve your needs, please call 800-372-3331.<br />
<strong>Advance</strong> HID Ballast Part Number Explanation<br />
71A 60 9 1<br />
-500D<br />
Suffix Code*<br />
(as applicable)<br />
-001DB ballast replacement kit with dry capacitor and integral ignitor<br />
-001D ballast replacement kit with dry film capacitor<br />
-001 ballast replacement kit with oil filled capacitor<br />
-500D core & coil ballast with dry film capacitor<br />
-500 core & coil ballast with oil filled capacitor<br />
-510D core & coil ballast with welded bracket and dry film capacitor<br />
-510 core & coil ballast with welded bracket and oil filled capacitor<br />
-540D core & coil ballast with welded angle bracket and dry film capacitor<br />
-600 core & coil ballast (no capacitor)<br />
-610 core & coil ballast with welded bracket (no capacitor)<br />
* Add additional feature codes to the end of suffix where applicable.<br />
i.e. -B = Integral Ignitor, -P = Thermally Protected, -J = J-Box Mounting,<br />
-A = Aluminum Secondary Coil, T-120V Tap<br />
Design Code<br />
INPUT<br />
VOLTAGE<br />
CODE<br />
60 Hz Voltages<br />
50 Hz Voltages<br />
0 = 120V A = 120/277/347V<br />
M = 100/200V<br />
1 = 208V B = 347V<br />
N = 120/220-240V<br />
2 = 240V C = 120/347V<br />
R = 220/240V<br />
3 = 277V D = 120/240/347V<br />
4 = 480V E = 120/208/240V or 208/240V<br />
5 = 120/240V or F = 277/480V, 277/347V, 277/347/480V or<br />
120/208/240/277/480V 347/480V<br />
6 = 240/480V H = 127/220V<br />
7 = 120/208/240/277V J = 220V or 220/240V<br />
8 = 120/277V Y = 100V or 100/200V<br />
9 = 120/208/240/277V<br />
HID<br />
Lamp Type/Wattage/Ballast Circuit Code<br />
Ballast<br />
Type<br />
71A = Core and Coil Ballast<br />
72C = F-Can Ballast<br />
73B = Encapsulated Core and Coil Ballast<br />
74P = Postline Ballast<br />
77K = Val-U-Pak Replacement Ballast Kit<br />
77L = Val-U-Pak Plus Replacement Ballast kit (includes lamp)<br />
78E = Indoor Enclosed Ballast<br />
79W = Outdoor Weatherproof Ballast<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 5-13
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
Mercury<br />
Input<br />
Volts<br />
Catalog<br />
✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max<br />
•<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Dimensions<br />
Fig<br />
A<br />
B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 156-157) to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(Pg 113) 5-3)<br />
50 Watt Lamp, ANSI Code H46<br />
120/277 71A1580 CWA 63 1.1/.5 250 3.2 A 1 1.1 2.3 7 250 7C070L33-R D 3.5 A/A<br />
120<br />
71A1800<br />
71A1800-001<br />
HX-NPF 74 2.1 240 7 B 1 .8 1.9 NOT AVAILABLE<br />
3.0 A<br />
75 Watt Lamp, ANSI Code H43<br />
120/277 71A2080 CWA 93 .9/.4 250 3/1 A 1 1.1 2.3 8 280 7C080L33-R<br />
D 3.5 A/A<br />
120 71A2303 HX-NPF 96 2.6 245 7 B 6 .9 1.9 NOT AVAILABLE<br />
2.8 F<br />
100 Watt Lamp, ANSI Code H38 or H44<br />
120<br />
480<br />
120/208/<br />
240/277<br />
120/208/<br />
240/277<br />
120/<br />
277/347<br />
120/<br />
277/347<br />
71A2501<br />
71A2541<br />
CWA<br />
120<br />
125<br />
71A2591 CWA 125<br />
71A2571-001D CWA 125<br />
71A25A1 CWA 125<br />
71A25A1-001D CWA 125<br />
1.1<br />
.3<br />
1.1/.6/<br />
.6/.5<br />
1.1/.6/<br />
.6/.5<br />
1.1/<br />
.5/.4<br />
1.1/<br />
.5/.4<br />
250<br />
250<br />
250<br />
250<br />
250<br />
3<br />
1<br />
3/2/<br />
2/2<br />
3/2/<br />
2/2<br />
3/<br />
2/1<br />
3/<br />
2/1<br />
A<br />
A<br />
A<br />
A<br />
A<br />
1<br />
1.1<br />
1.2<br />
2.3<br />
2.5<br />
10 280 7C100M33-R D<br />
4.0<br />
4.5<br />
1 1.5 2.8 10 280 7C100M33-R D 5.0<br />
1 1.5 2.8 10 280 7C100M33-R D 5.0<br />
1 1.5 2.8 10 280 7C100M33-R D 5.0<br />
1 1.5 2.8 10 280 7C100M33-R D 5.0<br />
B<br />
D<br />
D/D/<br />
D/D<br />
D/D/<br />
D/D<br />
B/<br />
B/B<br />
B/<br />
B/B<br />
120 71A2800<br />
71A2800-001<br />
HX-NPF 125 3.6 255 8 B1 1 1.4 2.4 NOT AVAILABLE 4.0 B<br />
HID • CORE & COIL<br />
MERCURY<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix<br />
-001 or -001D. Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For CWA circuits (except 71A1580, 71A2080), figure is operating current.<br />
For 71A1580 and 71A2080, figure is starting current. For HX and R circuits,<br />
figure is highest of starting, operating or open circuit current.<br />
Canadian replacement/retrofit ballast kit indicated by bold type.<br />
Refer to page 5-10.<br />
LINE V<br />
CAP<br />
COM<br />
LAMP<br />
COM<br />
LAMP<br />
Fig. B<br />
LINE V<br />
CAP<br />
CAP<br />
LAMP<br />
LINE V<br />
LINE V<br />
LINE V<br />
LAMP<br />
LAMP<br />
COM<br />
COM<br />
Fig. A<br />
5-14<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
HID<br />
Mercury<br />
Input<br />
Volts<br />
Catalog ✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max•<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Dimensions<br />
Fig A B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(Pg 5-3)<br />
125 Watt Lamp, ANSI Code H42<br />
120/<br />
240/347<br />
71A29D1 CWA 150<br />
1.3/<br />
.7/.5<br />
255<br />
4/<br />
2/2<br />
A<br />
1 1.4 2.5 12 280 7C120M33-R D 5.0<br />
B/<br />
B/A<br />
120/<br />
240/347<br />
71A29D1-001D CWA 150<br />
1.3/<br />
.7/.5<br />
255<br />
4/<br />
2/2<br />
A<br />
1 1.4 2.5 12 280 7C120M33-R D 5.0<br />
B/<br />
B/A<br />
175 Watt Lamp, ANSI Code H39<br />
or 150 Watt HPS Lamp, ANSI Code S63, EZ Lux (GE), Unalux (Osram-Sylvania), Retrolux (Philips)<br />
120 71A3002 CWA 205 1.9 215 5 A 1 1.6 2.9 17.5 240 7C175M33-R D 5.0 B<br />
NOM<br />
480<br />
120/208/<br />
240/277<br />
120/208/<br />
240/277<br />
120/<br />
240/347<br />
120/<br />
240/347<br />
71A3042<br />
71A3042-001D<br />
71A3092<br />
CWA<br />
CWA<br />
205<br />
200<br />
1.9/1.1/<br />
1.0/.9<br />
1.7/<br />
.9/.6<br />
1.7/<br />
.9/.6<br />
215<br />
240<br />
5/3/<br />
3/2<br />
5/<br />
3/2<br />
120<br />
71A3301<br />
71A3301-001<br />
HX-NPF 200 6.0 240 15 B1 1 1.4 2.5 NOT AVAILABLE<br />
4.5 B<br />
240 71A3325 R-NPF 195 2.7 240 7 C1 9 1.8 3.0 NOT AVAILABLE 3.5 D<br />
1<br />
1<br />
1.6<br />
1.7<br />
2.9<br />
2.9<br />
17.5<br />
17.5<br />
240<br />
240<br />
7C175M33-R<br />
1.9/1.1/<br />
5/3/<br />
71A3072-001D CWA 205<br />
215<br />
A 1 1.6 2.9 17.5 240 7C175M33-R D 5.0<br />
1.0/.9<br />
3/2<br />
71A30D2<br />
71A30D2-001D<br />
CWA 200 .5 240 2 A 1 1.8 2.9 17.5 240 7C175M33-R D 5.5 A<br />
CWA 200<br />
240<br />
5/<br />
3/2<br />
A<br />
A<br />
A<br />
7C175M33-R<br />
1 1.7 2.9 17.5 240 7C175M33-R D<br />
D<br />
D<br />
5.0<br />
5.5<br />
5.5<br />
B/C/<br />
C/C<br />
B/C/<br />
C/C<br />
A/<br />
A/A<br />
A/<br />
A/A<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001<br />
or -001D. Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For CWA circuits, figure is operating current. For HX and R circuits, figure<br />
is highest of starting, operating or open circuit current.<br />
Canadian replacement/retrofit ballast kit indicated by bold type.<br />
Refer to page 5-10.<br />
NOM Certified ballast available for Mexican and Central American markets.<br />
2 7 /16"<br />
B<br />
MAX.<br />
3 1 /2" 3 15 /16"<br />
A<br />
2 13 /16"<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
Fig. 1<br />
(3" x 4" core)<br />
HID • CORE & COIL<br />
MERCURY<br />
B<br />
MAX.<br />
4 3 /32"<br />
A<br />
2 5 /32"<br />
Fig. 6<br />
(2" x 4 " core)<br />
3 /4"<br />
B<br />
MAX.<br />
A<br />
2 3 /16"<br />
4 Holes cleared for<br />
#6 thru-bolts<br />
2 3 /16"<br />
2 5 /8" Fig. 9<br />
(2 5 /8" x 2 3 /16 Reactor Core )<br />
WELDED BRACKET DIMENSIONS<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
1,6 5.1 1.00 4.50 0.25<br />
9 4.0 0.75 3.50 0.28<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-15
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
Mercury<br />
Input<br />
Volts<br />
Catalog ✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max•<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Dimensions<br />
Fig A B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(Pg 5-3)<br />
250 Watt Lamp, ANSI Code H37<br />
120 71A3502 CWA 285 2.5 250 8 A 1 2.0 3.2 22.5 280 7C225P30-R D 6.0 D<br />
480<br />
71A3542<br />
71A3542-001D<br />
CWA 285 .7 250 2 A 1 2.3 3.4 22.5 280 7C225P30-R D 7.0 D<br />
480/120T 71A3542-T CWA 285 .7 250 2 A 1 2.3 3.4 22.5 280 7C225P30-R D 7.0 D<br />
120/208/<br />
240/277<br />
120/208/<br />
240/277<br />
120/<br />
240/347<br />
120/<br />
240/347<br />
71A3592 CWA 285<br />
71A3572-001D CWA 285<br />
71A35D2 CWA 285<br />
71A35D2-001D CWA 285<br />
2.5/1.4/<br />
1.3/1.1<br />
2.5/1.4/<br />
1.3/1.1<br />
2.5/<br />
1.3/.9<br />
2.5/<br />
1.3/.9<br />
250<br />
250<br />
250<br />
250<br />
8/5/<br />
5/3<br />
8/5/<br />
5/3<br />
8/<br />
5/3<br />
8/<br />
5/3<br />
A<br />
A<br />
A<br />
A<br />
1 2.5 3.7 22.5 280 7C225P30-R D 7.5<br />
1 2.5 3.7 22.5 280 7C225P30-R D 7.5<br />
1 2.5 3.7 22.5 280 7C225P30-R D 7.5<br />
1 2.5 3.7 22.5 280 7C225P30-R D 7.5<br />
120 71A3802 HX-NPF 285 6.9 235 20 B1 5 1.2 2.4 NOT AVAILABLE 6.0 B<br />
D/D/<br />
D/D<br />
D/D/<br />
D/D<br />
D/<br />
D/D<br />
D/<br />
D/D<br />
NOM<br />
220 71A35J2 CWA 285 1.6 250 5 A 1 2.0 3.2 22.5 280 7C225P30-R D 6.0 D<br />
HID • CORE & COIL<br />
MERCURY<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />
Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For CWA circuits, figure is operating current. For HX and R circuits, figure<br />
is highest of starting, operating or open circuit current.<br />
Canadian replacement/retrofit ballast kit indicated by bold type.<br />
Refer to page 5-10.<br />
NOM Certified ballast available for Mexican and Central American markets.<br />
LINE V<br />
CAP<br />
CAP<br />
LAMP<br />
B<br />
MAX.<br />
A<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
B<br />
MAX.<br />
2 7 /16"<br />
B<br />
MAX.<br />
3 1 /2" 3 15 /16"<br />
A<br />
A<br />
2 13 /16"<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
Fig. 1<br />
(3" x 4" core)<br />
3 1 /2"<br />
LINE V<br />
4 1 /4"<br />
LINE V<br />
LINE V<br />
COM<br />
Fig. A<br />
COM<br />
LAMP<br />
3 7 /8"<br />
4 3 /8" 4 3 /4"<br />
Fig. 2<br />
(4 1 /4" x 4 3 /4" core)<br />
4 15 /32"<br />
Fig. 5<br />
(3 1 /2" x 4 1 /2" NEMA Core)<br />
B<br />
MAX.<br />
A<br />
8 Holes cleared for<br />
#10 thru-bolts<br />
WELDED BRACKET DIMENSIONS<br />
3 7 /8"<br />
4 1 /4"<br />
4 3 /8"<br />
5 3 /8" 6 "<br />
Fig. 8<br />
(4 1 /4" x 6" core)<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
1 5.1 1.00 4.50 0.25<br />
5-16<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
HID<br />
Mercury<br />
Input<br />
Volts<br />
Catalog ✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max•<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Dimensions<br />
Fig A B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
U.L. Bench Top<br />
Rise Code 1029<br />
(Pg 5-3)<br />
Class H<br />
(180°C)<br />
ADVANCE<br />
Class N<br />
(200°C)<br />
400 Watt Lamp, ANSI Code H33<br />
71A4041<br />
480<br />
CWA 454 1.0 245 5 A 2 1.7 3.2 35 240 7C350P30-R D 10.0 D<br />
71A4041-001D<br />
480/120T 71A4041-T CWA 454 1.0 245 5 A 2 1.7 3.2 35 240 7C350P30-R D 10.0 D<br />
—<br />
—<br />
120/208/<br />
240/277<br />
71A4091 CWA 454<br />
3.9/2.2/<br />
2.0/1.7<br />
245<br />
10/8/<br />
5/5<br />
A<br />
2 1.8 3.3 35 240 7C350P30-R D 10.5<br />
D/C/<br />
C/B<br />
—<br />
N<br />
N<br />
120/208/<br />
240/277<br />
120/<br />
240/347<br />
120/<br />
240/347<br />
71A4071-001D CWA 454<br />
71A40D1 CWA 454<br />
71A40D1-001D CWA 454<br />
3.9/2.2/<br />
2.0/1.7<br />
3.9/<br />
2.0/1.3<br />
3.9/<br />
2.0/1.3<br />
245<br />
245<br />
245<br />
10/8/<br />
5/5<br />
10/<br />
5/4<br />
10/<br />
5/4<br />
A<br />
A<br />
A<br />
2 1.8 3.3 35 240 7C350P30-R D 10.5<br />
2 1.8 3.3 35 240 7C350P30-R D 10.5<br />
2 1.8 3.3 35 240 7C350P30-R D 10.5<br />
Two 400 Watt Lamps, ANSI Code H33 (2 Lamps in Series)<br />
120 71A4300-001 CWI 880 7.5 495 20 D 3 2.9 4.4 16 525 MD1606-100 O 20.3 E<br />
277 71A4330-001 CWI 880 3.3 495 10 D 3 2.9 4.4 16 525 MD1606-100 O 20.3 D<br />
480 71A4340-001 CWI 880 1.9 495 5 D 3 2.9 4.4 16 525 MD1606-100 O 20.3 E<br />
1000 Watt Lamp, ANSI Code H36<br />
480 71A5040-001 CWA 1080 2.3 425 10 A 8 2.9 4.8 24 450 MD2409-100 O 25.0 A<br />
120/208/<br />
240/277<br />
71A5070-001 CWA 1075<br />
9.8/5.6/<br />
4.9/4.3<br />
425<br />
20/15/<br />
10/10<br />
A<br />
8 2.9 4.8 24 450 MD2409-100 O 25.0<br />
D/C/<br />
C/B<br />
A/<br />
A/A<br />
A/<br />
A/A<br />
C/C/<br />
B/C<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
A<br />
A/A/<br />
A/A<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with<br />
suffix -001 or -001D. Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-500 includes core & coil with oil-filled capacitor<br />
-510 includes core & coil with welded bracket and oil-filled capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For CWA and CWI circuits, figure is operating current.<br />
Canadian replacement/retrofit ballast kit indicated by bold type.<br />
Refer to page 5-10.<br />
N Dual rated Class H (180°C) / ADVANCE Class N (200°C) insulation system.<br />
Refer to page 5-3 for additional information.<br />
HID • CORE & COIL<br />
MERCURY<br />
LINE V<br />
CAP<br />
CAP<br />
LAMP<br />
LINE V<br />
CAP<br />
CAP<br />
LAMP<br />
LINE V<br />
LAMP<br />
LINE V<br />
LINE V<br />
COM<br />
Fig. A<br />
COM<br />
LAMP<br />
LINE V<br />
Fig. D<br />
LAMP<br />
LAMP<br />
WELDED BRACKET DIMENSIONS<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
2 6.5 1.25 5.75 0.28<br />
3, 8 7.8 2.75 6.13 0.25<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-17
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
Metal Halide<br />
NOM<br />
Input<br />
Volts<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
120 71A5005-P✥ HX-NPF<br />
HX-HPF<br />
277<br />
277<br />
71A5037-BP✥<br />
71A5037-J✥<br />
Watts<br />
Input<br />
35/39 Watt Lamp, ANSI Code M130<br />
55<br />
48<br />
48<br />
Max •<br />
Input<br />
Current<br />
1.5<br />
1.1<br />
1.6/.7<br />
.9/.4<br />
.7<br />
.6<br />
.7<br />
.6<br />
.7<br />
.6<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
230<br />
277<br />
277<br />
Fuse<br />
Rating<br />
(Amps)<br />
4<br />
3<br />
Wiring<br />
Dia<br />
Fig<br />
Dimensions<br />
A<br />
B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
6 .9 1.8 28 120 7C280M12 D<br />
Total<br />
Weight<br />
(Ibs)<br />
2.0<br />
2.2<br />
3.3<br />
3.5<br />
1.6<br />
1.8<br />
1.7<br />
1.9<br />
1.9<br />
2.0<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
LI533-H4 15 A<br />
HX-NPF<br />
4/2<br />
120/277 71A5081<br />
56<br />
230<br />
K 1 .8 2.1 5 280 7C050L33 D<br />
LI533-H4 15 B/A<br />
HX-HPF<br />
3/1<br />
R-NPF<br />
277 71A5037-P✥<br />
48<br />
277 2 G 9 .8 1.9 5 280 7C050L33 D<br />
R-HPF<br />
LI533-H4 10 A<br />
R-NPF<br />
R-HPF<br />
R-NPF<br />
R-HPF<br />
2<br />
2<br />
F<br />
H<br />
J<br />
9<br />
11<br />
1.0<br />
1.0<br />
2.7<br />
3.0<br />
5<br />
5<br />
280<br />
280<br />
7C050L33<br />
7C050L33<br />
D<br />
D<br />
Integral Ignitor<br />
J-Box with<br />
Integral Ignitor<br />
2<br />
2<br />
A<br />
A<br />
50 Watt Lamp, ANSI Code M110 or M148<br />
120 71A5105-P✥ HX-NPF<br />
HX-HPF<br />
120/277 71A5181<br />
71A5181-001D<br />
277<br />
277<br />
277<br />
71A5137-P✥<br />
71A5137-BP✥<br />
71A5137-J✥<br />
69<br />
2.0<br />
1.1<br />
260<br />
5<br />
3<br />
6 1.0 1.9 28 120 7C280M12 D 2.3 LI533-H4 15 A<br />
HX-HPF 72 1.0/.5 260 3/2 K 1 1.2 2.1 6 280 7C060L33 D 4.0 LI533-H4 10 A/A<br />
R-NPF<br />
R-HPF<br />
R-NPF<br />
R-HPF<br />
R-NPF<br />
R-HPF<br />
62<br />
62<br />
62<br />
.7<br />
.6<br />
.7<br />
.6<br />
.7<br />
.6<br />
277<br />
277<br />
277<br />
2<br />
2<br />
2<br />
F<br />
G<br />
H<br />
J<br />
9<br />
9<br />
11<br />
1.1<br />
1.1<br />
1.1<br />
2.2<br />
2.6<br />
3.3<br />
5<br />
5<br />
5<br />
280<br />
280<br />
280<br />
7C050L33<br />
7C050L33<br />
7C050L33<br />
D<br />
D<br />
D<br />
2.0<br />
2.2<br />
2.0<br />
2.2<br />
2.3<br />
2.5<br />
LI533-H4<br />
Integral Ignitor<br />
J-Box with<br />
Integral Ignitor<br />
2<br />
2<br />
2<br />
A<br />
A<br />
C<br />
HID • CORE & COIL<br />
METAL HALIDE<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />
Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For HX and R circuits, figure is highest of starting, operating or open circuit current.<br />
✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range ignitor<br />
model shown for use within fixtures. If a Long Range ignitor is required for remote<br />
mounting, specify on order. See pages 5-50 to 5-53 for additional information.<br />
✥ Includes auto-reset thermal protection<br />
NOM Certified ballast available for Mexican and Central American markets.<br />
120 V<br />
COM<br />
Fig. F<br />
LAMP<br />
X3 X1<br />
IGNITOR<br />
X2<br />
COM<br />
INTEGRAL<br />
IGNITOR INTEGRATED BALLAST<br />
IGNITOR BALLAST<br />
LINE V<br />
LAMP<br />
IGNITOR<br />
CAP<br />
COM<br />
Fig. FIG. H<br />
LAMP<br />
CAP<br />
LAMP<br />
LAMP<br />
LINE V<br />
LAMP<br />
COM<br />
LINE V<br />
(OPTIONAL)<br />
CAP<br />
X3<br />
IGNITOR<br />
X2<br />
X1<br />
LAMP<br />
COM<br />
CAP<br />
LINE V<br />
LINE V<br />
X3 X1<br />
IGNITOR<br />
X2<br />
LAMP<br />
CAP<br />
LINE V<br />
LINE V<br />
COM<br />
J-BOX BALLAST<br />
COM<br />
COM<br />
COM<br />
Fig. G<br />
Fig. J<br />
J-BOX<br />
Fig. K<br />
5-18<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
HID<br />
Metal Halide<br />
NOM<br />
NOM<br />
Input<br />
Volts<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
70 Watt Lamp, ANSI Code M98 (Medium Base) or M143<br />
120 71A5205-P✥ HX-NPF 94<br />
HX-PFC<br />
120/277 71A5282<br />
HX-HPF 90<br />
127/220 71A52H2<br />
120/208/<br />
240/277<br />
2.6<br />
1.4<br />
1.9/.8<br />
1.9/.9<br />
71A5292<br />
71A5292-001D HX-HPF 90 1.9/1.0/<br />
.9/.8<br />
120/<br />
277/347 71A52A2 HX-HPF 90 1.9/<br />
.8/.7<br />
120/<br />
277/347 71A52A2-001D HX-HPF 90 1.9/<br />
.8/.7<br />
277<br />
277<br />
277<br />
71A5237-P✥<br />
71A5237-BP✥<br />
71A5237-J✥<br />
255<br />
6<br />
4<br />
Wiring<br />
Dia<br />
Fig<br />
Dimensions<br />
A<br />
B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
6 1.6 2.7 36 120 7C360M12 D<br />
Total<br />
Weight<br />
(Ibs)<br />
3.5<br />
3.7<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
LI533-H4 10 B<br />
255 4/2 K 1 1.5 2.8 8 280 7C080L33-R D 5.0 LI533-H4 15 A/A<br />
255<br />
255<br />
255<br />
70 Watt Lamp, ANSI Code M85 (OSI Briteline/HQI, GE MQI ARC70/TD, Philips MHN70/TD)<br />
4/3/<br />
2/2<br />
4/<br />
2/2<br />
4/<br />
2/2<br />
3<br />
2<br />
3<br />
2<br />
3<br />
2<br />
70 Watt Lamp, ANSI Code M139 (Philips CDM70/T6, CDM70/TD)<br />
120/277 71A5281<br />
120/347 71A52C1<br />
120/277 71A5280<br />
120/347 71A52C0<br />
HX-HPF 94<br />
1.6/.7<br />
1.6/.6<br />
245<br />
220<br />
4/2<br />
4/2<br />
F<br />
K<br />
K<br />
K<br />
K<br />
1 1.5 2.8 8 280 7C080L33-R D 5.0 LI533-H4 15<br />
1 1.5 2.8 8 280 7C080L33-R D 5.0 LI533-H4 15<br />
1 1.5 2.8 8 280 7C080L33-R D 5.0 LI533-H4 15<br />
1 1.5<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />
Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
1 3 /4"<br />
• For HX and R circuits, figure is highest of starting, operating or open<br />
circuit current.<br />
✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range<br />
ignitor model shown for use within fixtures. If a Long Range<br />
ignitor is required for remote mounting, specify on order. See pages<br />
5-50 to 5-53 for additional information.<br />
Canadian replacement/retrofit ballast kit indicated by bold type. Refer to page 5-10.<br />
✥ Includes auto-reset thermal protection<br />
NOM Certified ballast available for Mexican and Central American markets.<br />
A<br />
B<br />
R-NPF<br />
R-HPF<br />
R-NPF<br />
R-HPF<br />
R-NPF<br />
R-HPF<br />
1 / 2 "<br />
1 / 2 "-14<br />
STRAIGHT PIPETHREAD<br />
2 5 / 8 "<br />
Fig. 11<br />
J-Box Ballast<br />
85<br />
85<br />
85<br />
HX-HPF 94<br />
2 3 / 16 "<br />
1 27 / 32 "<br />
1.2<br />
.8<br />
1.2<br />
.8<br />
1.2<br />
.8<br />
1.6/.7<br />
1.6/.6<br />
1 13 / 16<br />
277<br />
277<br />
277<br />
245<br />
220<br />
4/2<br />
4/2<br />
B<br />
MAX.<br />
G<br />
H<br />
J<br />
K<br />
9<br />
9<br />
11<br />
4 3 /32"<br />
A<br />
1.6<br />
1.5<br />
1.5<br />
1 1.5<br />
2 5 /32"<br />
2.7<br />
2.9<br />
3.5<br />
2.7<br />
2.8<br />
2.7<br />
2.8<br />
8<br />
8<br />
8<br />
8 280 7C080L33-R D 5.5 LI522-H5 30<br />
B<br />
MAX.<br />
Fig. 6<br />
(2" x 4 " core)<br />
2 3 /16"<br />
280<br />
280<br />
280<br />
A<br />
7C080L33-R<br />
7C080L33-R<br />
7C080L33-R<br />
2 3 /16"<br />
4 Holes cleared for<br />
#6 thru-bolts<br />
2 5 /8" Fig. 9<br />
(2 5 /8" x 2 3 /16 Reactor Core )<br />
D<br />
D<br />
D<br />
2 7 /16"<br />
2.7<br />
2.9<br />
2.7<br />
2.9<br />
3.0<br />
3.2<br />
B<br />
MAX.<br />
LI533-H4<br />
Integral Ignitor<br />
J-Box with<br />
Integral Ignitor<br />
8 280 7C080L33-R D 5.5 LI533-H4<br />
3 1 /2" 3 15 /16"<br />
WELDED BRACKET DIMENSIONS<br />
A<br />
2 13 /16"<br />
Fig. 1<br />
(3" x 4" core)<br />
A/A/<br />
A/A<br />
A/<br />
A/A<br />
A/<br />
A/A<br />
A/A<br />
A/A<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
1, 6 5.1 1.00 4.50 0.25<br />
9 4.0 0.75 3.50 0.28<br />
11 Not Available<br />
10<br />
2<br />
2<br />
10<br />
5<br />
A<br />
A<br />
C<br />
A/A<br />
A/A<br />
HID • CORE & COIL<br />
METAL HALIDE<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 5-19
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
Metal Halide<br />
NOM<br />
NOM<br />
Input<br />
Volts<br />
480/<br />
120T<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
100 Watt Lamp, ANSI Code M90 or M140<br />
120/277<br />
127/220<br />
120/208/<br />
240/277<br />
120/<br />
277/347<br />
71A5380<br />
71A53H0<br />
71A5390<br />
71A5390-001D<br />
HX-HPF<br />
HX-HPF<br />
129<br />
129<br />
HX-HPF 129<br />
2.3/1.0<br />
2.2/1.3<br />
2.3/1.4/<br />
1.2/1.0<br />
71A53A0<br />
71A53A0-001D HX-HPF 129 2.6/<br />
1.2/1.0<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
265<br />
280<br />
265<br />
280<br />
Fuse<br />
Rating<br />
(Amps)<br />
6/3<br />
5/3<br />
6/4/<br />
3/3<br />
6/<br />
3/2<br />
Wiring<br />
Dia<br />
K<br />
K<br />
K<br />
K<br />
Fig<br />
Dimensions<br />
1<br />
1<br />
Cap Catalog<br />
Number<br />
71A5340-T HX-HPF 132 .6 260 2 K 1 1.7 2.9 10 300 7C100M33-R D 5.5 LI533-H4 25 C<br />
120/277 71A5383 CWA 128 1.1/.5 222 3/2 M 1 1.6 2.8 10 330 7C100M33-R D 5.5 LI533-H4 2 C/C<br />
A<br />
1.5<br />
1.7<br />
B<br />
2.8<br />
2.9<br />
Mfd<br />
12<br />
12<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
280<br />
280<br />
7C120M33-R<br />
7C120M33-R<br />
Dry<br />
or<br />
Oil<br />
1 1.5 2.8 12 280 7C120M33-R D<br />
1 1.7 2.9 12 280 7C120M33-R D<br />
D<br />
D<br />
Total<br />
Weight<br />
(Ibs)<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
LI533-H4<br />
LI533-H4<br />
LI533-H4<br />
LI533-H4<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
20<br />
20<br />
20<br />
25<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
B/A<br />
A/B<br />
B/C/<br />
A/A<br />
B/<br />
B/B<br />
277<br />
277<br />
277<br />
71A5337-P✥<br />
71A5337-BP✥<br />
71A5337-J✥<br />
R-NPF<br />
R-HPF<br />
R-NPF<br />
R-HPF<br />
R-NPF<br />
R-HPF<br />
118<br />
118<br />
118<br />
1.3<br />
1.1<br />
1.3<br />
1.1<br />
1.3<br />
1.1<br />
277<br />
277<br />
277<br />
3<br />
3<br />
3<br />
G<br />
H<br />
J<br />
9<br />
9<br />
11<br />
1.7<br />
1.8<br />
1.8<br />
2.8<br />
3.1<br />
3.9<br />
10<br />
10<br />
10<br />
280<br />
280<br />
280<br />
7C100M33-R<br />
7C100M33-R<br />
7C100M33-R<br />
D<br />
D<br />
D<br />
3.0<br />
3.2<br />
3.0<br />
3.2<br />
3.3<br />
3.5<br />
LI533-H4<br />
Integral Ignitor<br />
J-Box with<br />
Integral Ignitor<br />
2<br />
2<br />
2<br />
A<br />
A<br />
C<br />
HID • CORE & COIL<br />
METAL HALIDE<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D. Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor) (71A5337 only)<br />
• For CWA circuits, figure is operating current. For HX and R circuits, figure is highest of starting,<br />
operating or open circuit current.<br />
NOM Certified ballast available for Mexican and Central American markets.<br />
LINE V<br />
LAMP<br />
LAMP<br />
COM<br />
✝✝ Each ballast requiring an ignitor is furnished standard<br />
with the Short Range ignitor model shown for<br />
use within fixtures. If a Long Range ignitor is<br />
required for remote mounting, specify on order. See<br />
pages 5-50 to 5-53 for additional information.<br />
Canadian replacement/retrofit ballast kit indicated<br />
by bold type. Refer to page 5-10.<br />
✥ Includes auto-reset thermal protection<br />
LINE V<br />
LINE V<br />
LAMP<br />
(OPTIONAL)<br />
CAP<br />
X3<br />
X1<br />
IGNITOR<br />
X2<br />
LAMP<br />
LINE V<br />
LINE V<br />
X3 X1<br />
IGNITOR<br />
X2<br />
LAMP<br />
COM<br />
CAP<br />
LINE V<br />
CAP<br />
CAP<br />
CAP<br />
Fig. G<br />
J-BOX BALLAST<br />
Fig. J<br />
J-BOX<br />
COM<br />
COM<br />
Fig. L<br />
INTEGRATED<br />
IGNITOR BALLAST<br />
LINE V<br />
LAMP<br />
CAP<br />
LAMP<br />
LINE V<br />
LAMP<br />
LINE V<br />
LINE V<br />
IGNITOR<br />
CAP<br />
INTEGRAL<br />
IGNITOR BALLAST<br />
COM<br />
LAMP<br />
LINE V<br />
LINE V<br />
COM<br />
CAP<br />
CAP<br />
CAP<br />
X3 X1<br />
IGNITOR<br />
X2<br />
COM<br />
LAMP<br />
COM<br />
CAP<br />
LINE V<br />
LINE V<br />
LINE V<br />
X3 X1<br />
IGNITOR<br />
X2<br />
LAMP<br />
Fig. H<br />
Fig. M<br />
COM<br />
COM<br />
Fig. K<br />
5-20<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
HID<br />
Metal Halide<br />
NOM<br />
New<br />
NOM<br />
Input<br />
Volts<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Fig<br />
Dimensions<br />
A<br />
B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
150 Watt Lamp, ANSI Code M102 or M142<br />
120/277 71A5482 HX-HPF 185 3.7/1.6 265 10/4 K 1 2.3 3.9 16 280 7C160M33 D 7.0 LI533-H4 10<br />
120/208/<br />
240/277<br />
480/<br />
120T<br />
71A5492<br />
71A5492-001D HX-HPF 185 3.7/2.1/<br />
1.8/1.6<br />
120/<br />
277/347 71A54A2 HX-HPF 185 3.7/<br />
1.6/1.3<br />
265<br />
265<br />
10/5/<br />
5/4<br />
10/<br />
4/3<br />
1 2.3 3.9 16 280 7C160M33 D<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
1 2.3 3.9 16 280 7C160M33 D 7.0 LI533-H4 10<br />
Linear<br />
277 71A5437-P✥ Reactor 173 1.5 277 4 G 9 2.5 3.8 14 280 7C140M33-R<br />
HPF<br />
Linear<br />
277 71A5437-BP✥ Reactor 173 1.5 277 4 H 9 2.5 4.0 14 280 7C140M33-R<br />
HPF<br />
Linear<br />
277 71A5437-J✥ Reactor 173 1.5 277 4 J 11 2.5 4.5 14 280 7C140M33-R<br />
HPF<br />
150 Watt Lamp, ANSI Code M81 (OSI Briteline/HQI, GE Arcstream MQI, Philips MHN-TD)<br />
120/277 71A5480 HX-HPF 185 3.6/1.7 240 9/4 K 1 2.5 3.8 16 300 7C160M33<br />
120/208/<br />
3.6/2.1/ 9/6/<br />
71A5490 HX-HPF 185<br />
240<br />
240/277<br />
1.8/1.6<br />
5/4<br />
K 1 2.5 3.8 16 300 7C160M33<br />
120/347 71A54C0 HX-HPF 185 3.6/1.30 240 9/4 K 1 2.5 3.8 16 300 7C160M33<br />
L<br />
K<br />
K<br />
7.0 LI533-H4 10<br />
71A5442-T HX-HPF 185 .9 270 3 K 1 2.8 4.0 16 280 7C160M33 D 9.0 LI533-H4 10<br />
120/<br />
277/347 71A54A3 Super<br />
CWA<br />
189<br />
1.7/<br />
.8/.7<br />
187 5/2/2 L1 1 2.7 4.0 22 240 7C220M24-R D 9.0 LI501-J4 15<br />
D<br />
D<br />
D<br />
8.5<br />
8.5<br />
8.5<br />
LI522-H5<br />
LI522-H5<br />
LI522-H5<br />
20<br />
20<br />
20<br />
C/A<br />
C/C/<br />
A/A<br />
F/E<br />
120/277 71A5486 CWA 189 1.7/.8 187 5/2 1 2.7 4.0 22.5 240 7C225P30-R D 9.0 LI523-H5 2 F/E<br />
D<br />
D<br />
D<br />
4.2<br />
4.2<br />
4.5<br />
LI533-H4<br />
Integral Ignitor<br />
J-Box with<br />
Integral Ignitor<br />
15<br />
15<br />
15<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
C/B<br />
C/C/<br />
C/C<br />
B<br />
E/<br />
E/E<br />
C/<br />
B/A<br />
B<br />
B<br />
B<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D. Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For CWA circuits, figure is operating current. For HX and Linear Reactor circuits, figure is highest of<br />
starting, operating or open circuit current.<br />
✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range ignitor model shown<br />
for use within fixtures. If a Long Range ignitor is required for remote mounting, specify on order.<br />
See pages 5-50 to 5-53 for additional information.<br />
✥ Includes auto-reset thermal protection<br />
NOM Certified ballast available for Mexican and Central American markets.<br />
2 7 /16"<br />
B<br />
MAX.<br />
3 1 /2" 3 15 /16"<br />
A<br />
2 13 /16"<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
Fig. 1<br />
(3" x 4" core)<br />
HID • CORE & COIL<br />
METAL HALIDE<br />
B<br />
MAX.<br />
A<br />
4 Holes cleared for<br />
#6 thru-bolts<br />
1 3 /4"<br />
2 3 /16"<br />
2 3 /16"<br />
2 5 /8" Fig. 9<br />
(2 5 /8" x 2 3 /16 Reactor Core )<br />
A<br />
B<br />
1 / 2 "<br />
2 5 / 8 "<br />
1 / 2 "-14<br />
STRAIGHT PIPETHREAD<br />
Fig. 11<br />
2 3 / 16 "<br />
1 27 / 32 "<br />
1 13 / 16 "<br />
WELDED BRACKET DIMENSIONS<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
1 5.1 1.00 4.50 0.25<br />
9 4.0 0.75 3.50 0.28<br />
11 Not Available<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-21
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
HID • CORE & COIL<br />
METAL HALIDE<br />
Metal Halide<br />
Input<br />
Volts<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
LINE V<br />
LINE V<br />
LINE V<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
LAMP 1<br />
X3<br />
X1<br />
X2<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
IGNITOR<br />
Fuse<br />
Rating<br />
(Amps)<br />
LAMP<br />
Wiring<br />
Dia<br />
Dimensions<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D. Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For CWA and Regulated Lag circuits, figure is operating current.<br />
✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range<br />
ignitor model shown for use within fixtures. If a Long Range ignitor is<br />
required for remote mounting, specify on order. See pages 5-50 to 5-53 for<br />
additional information.<br />
Canadian replacement/retrofit ballast kit indicated by bold type.<br />
Refer to page 5-10.<br />
NOM Certified ballast available for Mexican and Central American markets.<br />
Fig<br />
LINE V<br />
Mfd<br />
INTEGRATED<br />
INTEGRAL<br />
IGNITOR BALLAST<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
LAMP<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
Dry<br />
or<br />
Oil<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
Total<br />
Weight<br />
(Ibs)<br />
CAP<br />
CAP<br />
Fig. A<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
CAP<br />
Part<br />
Number<br />
480<br />
71A5540<br />
71A5540-001D<br />
CWA 210 0.5 305 2 A 1 2.5 4.0 10 400 7C100M40-R D 8.5 — — D<br />
480/120T 71A5540-T CWA 210 0.5 305 2 A 1 2.8 4.0 10 400 7C100M40-R D 8.5 — — D<br />
120/277 71A5580 CWA 210 1.8/.8 305 5/2 A 1 2.5 3.9 10 400 7C100M40-R D 6.8 — — C/D<br />
NOM 127/220 71A55H0 CWA 210 1.8/1.1 305 5/3 A 1 2.5 3.8 10 400 7C100M40-R D 6.8 — — B/B<br />
NOM<br />
NOM<br />
New<br />
175 Watt Lamp, ANSI Code M57 or H39; or 150 Watt Lamp, ANSI Code M107<br />
120<br />
277<br />
71A5500<br />
71A5530<br />
CWA 210<br />
1.8<br />
.8<br />
120/208/<br />
240/277 71A5590 CWA 210 1.8/1.1/<br />
.9/.8<br />
120/208/<br />
240/277 71A5570-001D CWA 210 1.8/1.1/<br />
.9/.8<br />
120/<br />
277/347 71A55A0 CWA 210 1.8/<br />
.8/.7<br />
120/<br />
277/347 71A55A0-001D CWA 210 1.8/<br />
.8/.7<br />
305<br />
305<br />
305<br />
305<br />
5<br />
2<br />
5/3/<br />
3/2<br />
5/3/<br />
3/2<br />
5/<br />
2/2<br />
175 Watt Lamp, ANSI Code M137 or M152 (Pulse-Start)<br />
120/208/ 71A5593<br />
240/277 71A5593-001D<br />
120 71A5504<br />
277/120T 71A5534-T<br />
347/120T 71A55B4-T<br />
480/120T 71A5544-T<br />
Super<br />
CWA<br />
120/<br />
277/347 71A55A3 Super<br />
CWA<br />
480/120T 71A5543-T<br />
Super<br />
CWA<br />
Regulated<br />
Lag<br />
208<br />
208<br />
220<br />
1.9/1.1/<br />
.9/.8<br />
1.9/<br />
.9/.7<br />
2.0<br />
0.8<br />
0.7<br />
0.5<br />
305<br />
275<br />
275<br />
310<br />
5/<br />
2/2<br />
5/3/<br />
3/3<br />
5/<br />
3/2<br />
5<br />
2<br />
2<br />
1<br />
A<br />
A<br />
A<br />
A<br />
A<br />
M<br />
M<br />
N<br />
A<br />
B<br />
CAP<br />
COM<br />
CAP<br />
Fig. M<br />
LAMP<br />
X3<br />
COM<br />
X1<br />
IGNITOR<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
1 2.5 3.5 10 400 7C100M40-R D 6.8 — —<br />
1 2.5 3.7 10 400 7C100M40-R D 6.8 —<br />
X2<br />
—<br />
LAMP<br />
LAMP<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
1 2.5 3.7 10 400 7C100M40-R D 6.8 — — C/D/<br />
D/D<br />
C/<br />
1 2.5 3.7 10 400 7C100M40-R D 7.0 — —<br />
C/D<br />
1 2.5 3.7 10 400 7C100M40-R D 7.0 — —<br />
1 2.3 3.5 11 370 7C110M40 D 7.0 LI533-H4 2<br />
1 2.3 3.5 11 370 7C110M40 D 7.0 LI533-H4 2<br />
206 .5 275 2 M 1 2.3 3.5 11 370 7C110M40 D 7.0 LI533-H4 2 C<br />
3 1.7 3.5 17 400 7C170P40 D 12.5 LI534-H5 20<br />
LAMP<br />
C<br />
D<br />
C/D/<br />
D/D<br />
C/<br />
C/D<br />
C/C/<br />
C/C<br />
C/<br />
C/C<br />
A<br />
A<br />
A<br />
A<br />
LAMP 2<br />
LINE V<br />
CAP<br />
CAP<br />
IGNITOR<br />
LAMP<br />
CAP<br />
COM<br />
CAP<br />
Fig. N<br />
COM<br />
Fig. H<br />
5-22<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
HID<br />
Metal Halide<br />
NOM<br />
New<br />
Input<br />
Volts<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Fig<br />
Dimensions<br />
A<br />
B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
200 Watt Lamp, ANSI Code M136 (Pulse-Start)<br />
277<br />
71A5637-BP✥ Linear<br />
Reactor 218 1.3 277 4 H 10 1.0 3.1 12 280 7C120M33-R D 6.0<br />
71A5637-001D✥ HPF<br />
120/208/<br />
240/277<br />
120/<br />
277/347<br />
480/<br />
71A5642-T◆<br />
120T<br />
120/208/ 71A5692◆<br />
240/277 71A5692-001D<br />
120/<br />
277/347<br />
71A5693<br />
71A56A3<br />
71A56A2◆<br />
277/120T 71A5634-T<br />
Super<br />
CWA<br />
Super<br />
CWA<br />
Super<br />
CWA<br />
Super<br />
CWA<br />
Super<br />
CWA<br />
Regulated<br />
Lag<br />
240<br />
240<br />
232<br />
232<br />
2.1/1.2/<br />
1.1/.9<br />
2.1/<br />
.9/.8<br />
2.0/1.2/<br />
1.0/.9<br />
2.1/<br />
.9/.7<br />
252<br />
263<br />
240<br />
235<br />
6/4/<br />
3/3<br />
5/<br />
2/2<br />
6/4/<br />
3/3<br />
6/<br />
3/2<br />
M<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Integral<br />
Ignitor<br />
M 2 1.4 3.0 15 330 7C150M33 D 8.5 LI533-H4 5<br />
M 2 1.4 3.0 15 330 7C150M33 D 8.5 LI533-H4 5<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
1 2.5 3.6 15 330 7C150M33 D 8.0 LI533-H4 2<br />
M 1 2.5 3.6 15 330 7C150M33 D 8.0 LI533-H4 2<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
2 A<br />
232 .5 240 2 M 1 2.5 3.6 15 330 7C150M33 D 8.0 LI533-H4 2 B<br />
244 .9 305 3 N 3 2.0 3.7 17 400 7C170P40 D 8.0 LI534-H5 2 A<br />
A/A/<br />
A/A<br />
A/<br />
A/A<br />
A/B/<br />
A/A<br />
C/<br />
A/A<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />
71A5637-001D kits also include welded angle bracket. Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-540D includes core & coil with welded angle bracket and dry-film capacitor<br />
(available for 71A5637-B only).<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For CWA and Regulated Lag circuits, Figure is operating current. For Linear<br />
Reactor circuits, Figure is highest of starting, operating and open circuit currents<br />
✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range<br />
ignitor model shown for use within fixtures. If a Long Range ignitor is<br />
required for remote mounting, specify on order. See pages 5-50 to 5-53 for<br />
additional information.<br />
✥ Includes auto-reset thermal protection<br />
◆ Compact 3 x 4 core design.<br />
A<br />
#10 thru-bolts<br />
B<br />
NOM Certified ballast available for Mexican<br />
MAX.<br />
and Central American markets.<br />
B<br />
MAX.<br />
A<br />
2 13 /16"<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
3 7 /8"<br />
4 3 /8" 4 3 /4"<br />
4 1 /4"<br />
4 Holes cleared for<br />
Fig. 2<br />
(4 1 /4" x 4 3 /4" core)<br />
31<br />
Suffix-510D provides<br />
weldedon<br />
mounting<br />
foot bracket.<br />
B<br />
MAX.<br />
A<br />
3.75<br />
4 Holes cleared for<br />
#6 thru-bolts<br />
4.06<br />
4.50 Fig. 10<br />
(4 1 /2" x 3 3 /4 Reactor Core )<br />
Bracket Detail<br />
(Fig. 10)<br />
Suffix-540D provides<br />
welded angle bracket<br />
to allow specific Linear<br />
Reactor ballasts to<br />
mount in 400-watt fixtures<br />
designed for<br />
standard CWA ballasts<br />
without brackets<br />
(Figure 2).<br />
HID • CORE & COIL<br />
METAL HALIDE<br />
2 7 /16"<br />
3 1 /2" 3 15 /16"<br />
Fig. 1<br />
(3" x 4" core)<br />
WELDED BRACKET DIMENSIONS<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
1 5.1 1.00 4.50 0.25<br />
3 7.8 2.75 6.13 0.25<br />
2, 10 6.5 1.25 5.75 0.28<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-23
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
Metal Halide<br />
Input<br />
Volts<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
250 Watt Lamp, ANSI Code M58 or H37<br />
120 71A5700<br />
2.5<br />
CWA 295<br />
277 71A5730<br />
1.1<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
300<br />
300<br />
Fuse<br />
Rating<br />
(Amps)<br />
8<br />
3<br />
Wiring<br />
Dia<br />
A<br />
Dimensions<br />
Fig A B<br />
1.5 3.0<br />
2<br />
1.5 3.0<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
15 400 7C150P40-R D<br />
Total<br />
Weight<br />
(Ibs)<br />
9.0<br />
9.0<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
— —<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
A<br />
A<br />
480 71A5740<br />
71A5740-001D<br />
480/120T 71A5740-T<br />
CWA<br />
CWA<br />
295<br />
295<br />
.7<br />
.7<br />
315<br />
315<br />
2<br />
2<br />
A<br />
A<br />
2<br />
2<br />
1.7<br />
1.7<br />
3.1<br />
3.1<br />
15<br />
15<br />
400<br />
400<br />
7C150P40-R<br />
7C150P40-R<br />
D<br />
D<br />
10.0<br />
10.0<br />
—<br />
—<br />
—<br />
—<br />
B<br />
B<br />
120/277 71A5780 CWA 295 2.5/1.1 300 8/3 A 2 1.5 3.0 15 400 7C150P40-R D 9.0 — — A/A<br />
NOM<br />
127/220 71A57H0 CWA 295 2.6/1.5 300 8/5 A 2 1.5 3.0 15 400 7C150P40-R D 9.0 — — A/B<br />
NOM<br />
120/208/<br />
240/277 71A5790 CWA 295 2.5/1.4<br />
1.3/1.1<br />
300<br />
8/5/<br />
5/3<br />
A<br />
2 1.5 3.0 15 400 7C150P40-R D 9.0 — — A/A/<br />
B/A<br />
120/208/<br />
240/277 71A5770-001D CWA 295 2.5/1.4<br />
1.3/1.1<br />
120/208/<br />
240/277/<br />
480<br />
71A5750<br />
71A5750-001D<br />
CWA 290<br />
2.6/1.5/<br />
1.4/1.1/<br />
.7<br />
120/<br />
277/347 71A57A0 CWA 295 2.5/<br />
1.1/.9<br />
300<br />
315<br />
315<br />
8/5/<br />
5/3<br />
8/5/<br />
5/3/<br />
2<br />
8/<br />
3/3<br />
A<br />
A<br />
A<br />
2 1.5 3.0 15 400 7C150P40-R D 9.0 — — A/A<br />
B/A<br />
2 1.6 3.1 15 400 7C150P40-R D 10.0 — — A/A/<br />
2 1.7 3.1 15 400 7C150P40-R D 10.0 — —<br />
B/A/<br />
B<br />
A/<br />
A/A<br />
120/<br />
277/347 71A57A0-001D CWA 295 2.5/<br />
1.1/.9<br />
315<br />
8/<br />
3/3<br />
A<br />
2 1.7 3.1 15 400 7C150P40-R D 10.0 — —<br />
A/<br />
A/A<br />
120<br />
277<br />
71A5701 ◆<br />
71A5731 ◆<br />
CWA<br />
294<br />
294<br />
2.6<br />
1.1<br />
300<br />
8<br />
3<br />
A<br />
1 3.0 4.2 15 400 7C150P40-R D 9.0 — —<br />
C<br />
D<br />
HID • CORE & COIL<br />
METAL HALIDE<br />
480<br />
120/208/<br />
240/277<br />
71A5741 ◆<br />
71A5741-OO1D<br />
71A5791 ◆ CWA 294<br />
120/208/ 71A5771-001D<br />
240/277 ◆<br />
CWA 294<br />
2.6/1.5/<br />
1.3/1.1<br />
2.6/1.5/<br />
1.3/1.1<br />
120/<br />
208/240 71A57E6 CWI 295 2.6/<br />
1.5/1.3<br />
CWA 298 .7 300 2 A 1 3.0 4.2 15 400 7C150P40-R D 9.0 — — H<br />
300<br />
300<br />
310<br />
8/5/<br />
5/3<br />
8/5/<br />
5/3<br />
7/<br />
4/4<br />
A<br />
A<br />
P<br />
1 3.0 4.2 15 400 7C150P40-R D 9.0 — — C/C/<br />
D/D<br />
1 3.0 4.2 15 400 7C150P40-R D 9.0 — — C/C/<br />
D/D<br />
2 1.8 3.3 13 425 MD1300-100 O 11.0 — —<br />
E/<br />
D/D<br />
✝ Ordering information:<br />
LINE V<br />
CAP<br />
LAMP<br />
CAP<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />
LINE V<br />
Refer to pages 5-5 to 5-9.<br />
LINE V<br />
LAMP<br />
LINE V<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
COM<br />
COM<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
Fig. A<br />
-500 includes core & coil with oil-filled capacitor<br />
-510 includes core & coil with welded bracket and oil-filled capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For CWA and CWI circuits, figure is operating current.<br />
✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range ignitor model shown for use within fixtures. If<br />
a Long Range ignitor is required for remote mounting, specify on order. See pages 5-50 to 5-53 for additional information.<br />
◆ Special compact 3 x 4 core design. Note Bench Top Rise Codes in last column.<br />
Canadian replacement/retrofit ballast kit indicated by bold type. Refer to page 5-10.<br />
NOM Certified ballast available for Mexican and Central American markets.<br />
INTEGRATED INTEGRAL<br />
IGNITOR BALLAST<br />
LINE V<br />
IGNITOR<br />
CAP<br />
COM<br />
Fig. H<br />
LINE V<br />
CAP<br />
CAP<br />
LINE V<br />
LINE V<br />
COM<br />
Fig. P<br />
LAMP<br />
LAMP 1<br />
LAMP 2<br />
LAMP<br />
LAMP<br />
5-24<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
HID<br />
Metal Halide<br />
New<br />
NOM<br />
Input<br />
Volts<br />
120<br />
240/120T<br />
277/120T<br />
347/120T<br />
480/120T<br />
Catalog✝<br />
Number<br />
71A5704<br />
71A5724-T<br />
71A5734-T<br />
71A57B4-T<br />
71A5744-T<br />
Circuit<br />
Type<br />
Regulated<br />
Lag<br />
Watts<br />
Input<br />
298<br />
Max •<br />
Input<br />
Current<br />
2.8<br />
1.4<br />
1.2<br />
1.0<br />
.7<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
305<br />
Fuse<br />
Rating<br />
(Amps)<br />
8<br />
4<br />
3<br />
3<br />
2<br />
Wiring<br />
Dia<br />
N<br />
Fig<br />
Dimensions<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Cap Catalog<br />
Number<br />
250 Watt Lamp, ANSI Code M138 or M153 (Pulse-Start)<br />
71A5737-BP✥ Linear<br />
277<br />
Reactor 272 1.5 277 4 H 10 1.3 3.2 14 280 7C140M33-R D 6.5<br />
71A5737-001D✥ HPF<br />
120/208/ 71A5792<br />
240/277 71A5792-001D<br />
Super<br />
CWA<br />
120/<br />
277/347 71A57A2 Super<br />
CWA<br />
480/<br />
120T<br />
71A5742-T<br />
Super<br />
CWA<br />
291<br />
291<br />
2.5/1.4/<br />
1.3/1.1<br />
2.5/<br />
1.1/.9<br />
275<br />
272<br />
8/5/<br />
5/3<br />
8/<br />
3/3<br />
250 Watt Lamp, ANSI Code M80 (HQI Double Ended and Mogul Base)<br />
120/277 71A5880 HX-HPF 290 5.5/2.3 240 6 K 2 2.6 4.3 20 280 7C200P33-R D 14.0 LI522-H5 5 A/A<br />
LINE V<br />
LAMP<br />
A<br />
B<br />
Mfd<br />
Min<br />
Volt<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Integral<br />
Ignitor<br />
M 2 1.5 3.1 17 330 7C170M33 D 9.5 LI533-H4 5<br />
M 2 1.5 3.1 17 330 7C170M33 D 9.5 LI533-H4 5<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
3 2.5 4.2 16 480 MD1606-000 O 16.0 LI534-H5 20<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
5 A<br />
281 .6 272 2 M 2 1.5 3.1 17 330 7C170M33 D 9.5 LI533-H4 5 B<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />
71A5737-001D kits also include welded angle bracket. Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-500 includes core & coil with oil-filled capacitor<br />
-510 includes core & coil with welded bracket and oil-filled capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range ignitor<br />
model shown for use within fixtures. If a Long Range ignitor is required for remote<br />
mounting, specify on order. See pages 5-50 to 5-53 for additional information.<br />
• For CWA and Regulated Lag circuits, figure is operating current. For HX circuits,<br />
figure is highest of starting, operating or open circuit currents.<br />
✥ Includes auto-reset thermal protection<br />
NOM Certified ballast available for Mexican and Central American markets.<br />
LINE V<br />
B<br />
MAX.<br />
A<br />
4 Holes cleared for<br />
#6 thru-bolts<br />
2 7 /16"<br />
B<br />
MAX.<br />
3 1 /2" 3 15 /16"<br />
A<br />
2 13 /16"<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
Fig. 1<br />
(3" x 4" core)<br />
3 7 /8"<br />
B<br />
MAX.<br />
4 3 /8" 4 3 /4"<br />
A<br />
4 1 /4"<br />
A/A/<br />
A/B<br />
A/<br />
A/A<br />
A<br />
A<br />
A<br />
A<br />
A<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
Fig. 2<br />
(4 1 /4" x 4 3 /4" core)<br />
HID • CORE & COIL<br />
METAL HALIDE<br />
LINE V<br />
X3<br />
X1<br />
LINE V<br />
IGNITOR<br />
X2<br />
LAMP<br />
3.75<br />
CAP<br />
CAP<br />
CAP<br />
COM<br />
COM<br />
Fig. M<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
CAP<br />
LINE V<br />
LINE V<br />
CAP<br />
LINE V<br />
COM<br />
LINE V<br />
COM<br />
LAMP 1<br />
X3 X1<br />
IGNITOR<br />
X2<br />
LAMP 2<br />
CAP<br />
CAP<br />
CAP<br />
Fig. N<br />
LAMP<br />
X3 X1<br />
IGNITOR<br />
X2<br />
COM<br />
Fig. K<br />
LAMP<br />
LAMP<br />
3.31<br />
Suffix-510D<br />
provides<br />
welded-on<br />
mounting<br />
foot bracket.<br />
4.06<br />
4.50 Fig. 10<br />
(4 1 /2" x 3 3 /4 Reactor Core )<br />
Suffix-540D provides<br />
welded angle bracket<br />
to allow specific<br />
Linear Reactor ballasts<br />
to mount in 400-<br />
watt fixtures designed<br />
for standard CWA ballasts<br />
without brackets<br />
(Figure 2).<br />
Bracket Detail<br />
(Fig. 10)<br />
WELDED BRACKET DIMENSIONS<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
1 5.1 1.00 4.50 0.25<br />
2, 10 6.5 1.25 5.75 0.28<br />
3 7.8 2.75 6.13 0.25<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-25
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
New<br />
NOM<br />
Metal Halide<br />
LL<br />
Input<br />
Volts<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Fig<br />
Dimensions<br />
A<br />
B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
320 Watt Lamp, ANSI Code M132 or M154 (Pulse-Start)<br />
71A5837-BP✥ Linear<br />
277<br />
Reactor 342 1.9 277 5 H 10 1.7 3.8 17.5 280 7C175M33-R D 9.5<br />
71A5837-001D✥ HPF<br />
480/<br />
120T<br />
71A5842-T<br />
71A5842-001DT<br />
120/208/ 71A5892<br />
240/277 71A5892-001D<br />
Super<br />
CWA<br />
Super<br />
CWA<br />
120/<br />
277/347 71A58A2 Super<br />
CWA<br />
Super<br />
127/220 71A58H2<br />
CWA<br />
120/208/<br />
240/270 71A5892-LL Super<br />
CWA<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
350 Watt Lamp, ANSI Code M131 (Pulse-Start)<br />
Linear<br />
71A5937-BP✥<br />
277<br />
Reactor 375 2.1 277 5 H 10 1.9 4.0 20 280 7C200P33-R D 10.0<br />
71A5937-001D✥<br />
HPF<br />
480/<br />
71A5943-T<br />
120T<br />
120/208/ 71A5993<br />
240/277 71A5993-001D<br />
Super<br />
CWA<br />
Super<br />
CWA<br />
120/<br />
277/347 71A59A3 Super<br />
CWA<br />
277/<br />
120T<br />
71A5934-T<br />
Regulated<br />
Lag<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Integral<br />
Ignitor<br />
Integral<br />
Ignitor<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
15 A<br />
368 .8 270 5 M 2 1.8 3.7 21 345 7C210P34-R D 11.0 LI533-H4 2 D<br />
368<br />
368<br />
3.3/1.9/<br />
1.7/1.4<br />
3.3/<br />
1.4/1.1<br />
270<br />
270<br />
8/6/<br />
5/3<br />
8/<br />
4/3<br />
M 2 1.8 3.7 21 345 7C210P34-R D 11.0 LI533-H4<br />
M 2 1.8 3.7 21 345 7C210P34-R D 11.0 LI533-H4 2<br />
365 3.0/1.7 270 8/6 M 2 1.8 3.7 21 340 7C210P34-R D 11.0 LI533-H4 2 B/B<br />
350<br />
400<br />
3.0/1.7/<br />
1.5/1.3<br />
3.4/2.0/<br />
1.7/1.5<br />
275<br />
270<br />
8/6/<br />
5/3<br />
10/7/<br />
5/5<br />
M<br />
M<br />
2 2.3 4.1 21 345 7C210P34-R D 14.5 LI533-H4 2<br />
2 1.8 3.7 22.5 345 7C225P34 D 11.0 LI533-H4 2<br />
2<br />
B/B/<br />
B/B<br />
C/<br />
C/C<br />
A/A/<br />
A/A<br />
15 A<br />
400 .9 275 3 M 2 1.8 3.7 22.5 345 7C225P34 D 11.0 LI533-H4 2 D<br />
400<br />
3.4/<br />
1.5/1.2<br />
275<br />
10/<br />
5/3<br />
M<br />
2 1.8 3.7 22.5 345 7C225P34 D 11.0 LI533-H4 2<br />
403 1.5 280 4 N 3 3.1 4.8 21 480 MD2100-030 O 21.0 LI533-H4 20 B<br />
D/C/<br />
C/C<br />
D/<br />
C/C<br />
HID • CORE & COIL<br />
METAL HALIDE<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />
71A5837-001D and 71A5937-001D kits also include welded angle bracket.<br />
Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-540D includes core & coil with welded angle bracket and dry-film capacitor<br />
(Available for 71A5837-B, 71A5937-B only)<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range<br />
ignitor model shown for use within fixtures. If a Long Range ignitor is<br />
required for remote mounting, specify on order. See pages 5-50 to 5-53<br />
for additional information.<br />
• For CWA circuits, figure is operating current. For Linear Reactor circuits,<br />
figure is highest starting, operating, or open circuit currents.<br />
✥ Includes auto-reset thermal protection<br />
NOM Certified ballast available for Mexican and Central American markets.<br />
LL Special High Efficiency/Low<br />
LINE V<br />
CAP<br />
LAMP<br />
CAP<br />
Loss Magnetic Ballast<br />
LINE V<br />
LINE V<br />
LINE V<br />
LAMP<br />
CAP<br />
LINE V<br />
3 7 /8"<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
B<br />
MAX.<br />
IGNITOR<br />
4 3 /8" 4 3 /4"<br />
INTEGRATED INTEGRAL<br />
IGNITOR BALLAST<br />
A<br />
LAMP<br />
CAP<br />
4 1 /4"<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
Fig. Fig. 2 2<br />
(4(4¹₄”x 1 /4" x 4 3 4³₄” /4" core)<br />
Fig. P<br />
CAP<br />
LAMP<br />
LAMP 1<br />
LAMP 2<br />
LAMP<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
CAP<br />
CAP<br />
COM<br />
LAMP 1<br />
X3 X1<br />
IGNITOR<br />
X2<br />
LAMP 2<br />
CAP<br />
LAMP<br />
X3 X1<br />
IGNITOR<br />
X2<br />
CAP<br />
COM<br />
Fig. M<br />
LAMP<br />
LAMP<br />
COM<br />
CAP<br />
COM<br />
Fig. A<br />
COM<br />
Fig. H<br />
COM<br />
CAP<br />
Fig. N<br />
5-26<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
HID<br />
Metal Halide<br />
NOM<br />
Input<br />
Volts<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
400 Watt Lamp, ANSI Code M59 or H33<br />
277 71A6037-B<br />
71A6037-001D<br />
120<br />
277<br />
480<br />
480/120T<br />
71A6001<br />
71A6031<br />
71A6041<br />
71A6041-001D<br />
71A6041-T<br />
Linear<br />
Reactor<br />
HPF<br />
CWA 458<br />
CWA<br />
CWA<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Fig<br />
Dimensions<br />
A<br />
B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
425 2.1 277 5 H 10 1.6 3.8 20 300 7C200P33-R D 9.0<br />
462<br />
462<br />
4.0<br />
1.7<br />
1.0<br />
1.0<br />
300<br />
300<br />
300<br />
10<br />
5<br />
4<br />
4<br />
A<br />
A<br />
A<br />
2<br />
2<br />
2<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
3.8<br />
3.8<br />
4.0<br />
4.0<br />
24 400 7C240P40-R D<br />
24<br />
24<br />
400<br />
400<br />
7C240P40-R<br />
7C240P40-R<br />
D<br />
D<br />
11.5<br />
11.5<br />
12.0<br />
12.0<br />
Ignitor<br />
(Page 5-50 to 5-54)<br />
Part<br />
Number<br />
Integral<br />
Ignitor<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
— —<br />
—<br />
—<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
2 A<br />
—<br />
—<br />
D<br />
E<br />
E<br />
E<br />
120/277 71A6081 CWA 458 4.0/1.7 300 10/5 A 2 2.0 3.9 24 400 7C240P40-R D 11.5 — — D/E<br />
NOM<br />
127/220 71A60H1 CWA 458 3.9/2.2 300 10/7 A 2 2.0 3.8 24 400 7C240P40-R D 11.5 — — D/D<br />
NOM<br />
120/208/<br />
240/277 71A6091 CWA 458 4.0/2.3/<br />
2.0/1.7<br />
120/208/<br />
240/277/<br />
71A6051<br />
4.1/2.3/<br />
71A6051-001D CWA 460 2.0/1.7/<br />
1.0<br />
480<br />
120/208/<br />
240/277 71A6071-001D CWA 458 4.0/2.3/<br />
2.0/1.7<br />
300<br />
300<br />
300<br />
10/7/<br />
5/5<br />
10/7/<br />
5/5/<br />
3<br />
10/7/<br />
5/5<br />
A<br />
A<br />
A<br />
2 2.0 3.9 24 400 7C240P40-R D 11.5 — — D/E/<br />
D/E<br />
2 2.2 4.0 24 400 7C240P40-R D 14.0 — — D/C/<br />
D/C/<br />
D<br />
2 2.2 4.0 24 400 7C240P40-R D 11.5 — — D/E/<br />
D/E<br />
120/<br />
277/347 71A60A1 CWA 460 4.0/<br />
1.7/1.4<br />
300<br />
10/<br />
5/4<br />
A<br />
2 2.0 4.0 24 400 7C240P40-R D 12.0 — —<br />
D/<br />
D/D<br />
120/<br />
277/347 71A60A1-001D CWA 460 4.0/<br />
1.7/1.4<br />
300<br />
10/<br />
5/4<br />
A<br />
2 2.4 4.0 24 400 7C240P40-R D 12.0 — —<br />
D/<br />
D/D<br />
120/<br />
208/240 71A60E6 CWI 465 4.2/<br />
2.5/2.1<br />
320 10/<br />
7/5<br />
P<br />
2 2.4 4.0 20 425 MD2006-100 O 14.0 — —<br />
E/<br />
D/D<br />
277/347 71A60F6 CWI 462 1.8/1.4 325 5/3 P 2 2.4 4.0 20 425 MD2006-100 O 14.0 — — E/D<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix<br />
-001 or -001D. 71A6037-001D kit also includes welded angle<br />
bracket. Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film<br />
capacitor<br />
-540D includes core & coil with welded angle bracket and dry-film<br />
capacitor. (Available for 71A6037-B only)<br />
-500 includes core & coil with oil-filled capacitor<br />
-510 includes core & coil with welded bracket and oil-filled<br />
capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For CWA and CWI circuits, figure is operating current.<br />
For Linear Reactor circuits, figure is highest of starting, operating, or<br />
open circuit currents.<br />
Canadian replacement/retrofit ballast kit indicated by bold type.<br />
Refer to page 5-10.<br />
*<br />
NOM<br />
Includes copper primary/aluminum secondary coils.<br />
Certified ballast available for Mexican and Central American markets.<br />
3.31<br />
Bracket Detail<br />
(Fig. 10)<br />
Suffix-510D provides<br />
welded-on mounting<br />
foot bracket.<br />
4 Holes cleared<br />
for #10 thru-bolts<br />
B<br />
MAX.<br />
A<br />
3.75<br />
4 Holes cleared for<br />
#6 thru-bolts<br />
4.06<br />
4.50 Fig. 10<br />
(4 1 /2" x 3 3 /4 Reactor Core )<br />
Suffix-540D provides welded angle bracket to<br />
allow specific Linear Reactor ballasts to mount<br />
in 400-watt fixtures designed for standard CWA<br />
ballasts without brackets (Figure 2).<br />
WELDED BRACKET DIMENSIONS<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
2, 10 6.5 1.25 5.75 0.28<br />
3 7.8 2.75 6.13 .25<br />
HID • CORE & COIL<br />
METAL HALIDE<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-27
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
NOM<br />
HID • CORE & COIL<br />
METAL HALIDE<br />
5-28<br />
Metal Halide<br />
LL<br />
Input<br />
Volts<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
400 Watt Lamp, ANSI Code M135 or M155 (Pulse-Start)<br />
277<br />
480/<br />
120T<br />
120/208/<br />
240/277<br />
120/208/<br />
240/277<br />
120/<br />
277/347<br />
120/208<br />
240<br />
Wiring<br />
Dia<br />
Fig<br />
Dimensions<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D. 71A6137-001D and<br />
71A6337-001D kits also include welded angle bracket. Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-540D includes core & coil with welded angle bracket and dry-film capacitor.<br />
(Available for 71A6137-B, 71A6337-B only)<br />
-500 includes core & coil with oil-filled capacitor<br />
CAP<br />
-510 includes core & coil with welded bracket and oil-filled capacitor<br />
-600 includes core & coil only (no capacitor)<br />
-610 includes core & coil with welded bracket (no capacitor)<br />
• For CWA, CWI, and Regulated Lag circuits, figure is operating current. For Linear<br />
Reactor circuits, figure is highest of starting,operating, or open circuit currents.<br />
LINE V<br />
✝✝ Each ballast requiring an ignitor iis furnished as standard with the Short Range<br />
LINE V<br />
ignitor model shown for use within fixtures. If a Long Range ignitor is required for<br />
LINE V<br />
remote mounting, specify on order. See pages 5-50 to 5-53 for additional information.<br />
LINE V<br />
✥ Includes auto-reset thermal protection<br />
NOM Certified ballast available for Mexican and Central American markets.<br />
COM<br />
LL Special High Efficiency/Low Loss Magnetic ballast<br />
A<br />
B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Cap Catalog<br />
Number<br />
450 Watt Lamp, ANSI Code M144 (Pulse-Start)<br />
277 71A6337-BP✥ Reactor<br />
Linear<br />
480 2.4 277 7 H 10 1.9 4.0 22.5 280 7C225P30-R D 9.5<br />
HPF<br />
480/<br />
120T<br />
120/208/<br />
240/277<br />
120/<br />
277/347<br />
277/<br />
120T<br />
71A6092<br />
71A6092-001D<br />
71A60A2<br />
71A6004<br />
71A6034-T<br />
71A60B4-T<br />
71A6044-T<br />
71A60E4-T<br />
71A6343-T<br />
71A6393<br />
71A63A3<br />
71A6334-T<br />
Super<br />
CWA<br />
Super<br />
CWA<br />
Super<br />
CWA<br />
Regulated<br />
Lag<br />
Super<br />
CWA<br />
Super<br />
CWA<br />
Super<br />
CWA<br />
Regulated<br />
Lag<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
Min<br />
Volt<br />
LINE V<br />
COM<br />
INTEGRAL<br />
INTEGRATED<br />
IGNITOR BALLAST<br />
IGNITOR BALLAST<br />
IGNITOR<br />
Fig. H<br />
LAMP 1<br />
X3<br />
LAMP 2<br />
CAP<br />
CAP<br />
X1<br />
X2<br />
CAP<br />
Fig. N<br />
IGNITOR<br />
LAMP<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
LAMP<br />
LAMP<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Integral<br />
Ignitor<br />
LAMP 1<br />
CAP<br />
Fig. V<br />
CAP<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
452 1.0 270 3 M 2 2.0 3.8 26 330 7C260P33-R D 12.0 LI533-H4 10 D<br />
452<br />
450<br />
465<br />
3.8/2.2/<br />
1.9/1.7<br />
3.8/<br />
1.7/1.4<br />
265<br />
270<br />
10/7/<br />
5/5<br />
10/<br />
5/4<br />
400 Watt Lamp, ANSI Code M128 or M135 or M155 (Pulse-Start)<br />
4.0<br />
10<br />
Regulated 1.7<br />
5<br />
Lag 465 1.4 315 4 N 3<br />
1.0<br />
4<br />
120<br />
277/120T<br />
347/120T<br />
480/120T<br />
208/<br />
240/120T<br />
71A6137-BP✥ Linear<br />
Reactor<br />
71A6137-001D✥ HPF<br />
Super<br />
71A6042-T<br />
CWA<br />
71A6092-LL<br />
71A61E6<br />
Super<br />
CWI<br />
425 2.1 277 5 H 10 1.6 3.8 20 280 7C200P33-R D 9.0<br />
434<br />
455<br />
3.8/2.2/<br />
1.9/1.7<br />
4.2/2.4/<br />
2.1<br />
2.3/2.0<br />
265<br />
265<br />
315<br />
10/6/<br />
5/5<br />
10/7<br />
5<br />
6/5<br />
M<br />
M<br />
M<br />
V<br />
N<br />
2 1.8 3.7 26 330 7C260P33-R D 11.0 LI533-H4 10<br />
2 2.3 4.1 26 330 7C260P33-R D 14.5 LI533-H4 2<br />
2 1.8 3.7 26 330 7C260P33-R D 11.0 LI533-H4 10<br />
3<br />
3.8<br />
3.8<br />
5.5<br />
5.5<br />
21<br />
21<br />
X3<br />
IGNITOR<br />
X1<br />
X2<br />
LAMP 2<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
5 A<br />
514 1.1 267 3 M 2 2.4 4.2 26.5 360 7C265P40-R D 14 LI533-H4 5 D<br />
508<br />
4.3/2.5/ 10/8/<br />
257<br />
2.2/1.9<br />
5/5<br />
M 2 2.3 3.9 26.5 360 7C265P40-R D 13.5 LI533-H4 5<br />
505<br />
4.3/<br />
10/<br />
268<br />
1.9/1.5<br />
5/4<br />
M 2 2.4 4.2 26.5 360 7C265P40-R D 14 LI533-H4 5<br />
530 2.0 310 5 N 3 4.0 5.9 21 525 MD2100-030 O 27 LI534-H5 2 B<br />
500<br />
500<br />
MD2100-030<br />
MD2100-030<br />
Integral<br />
Ignitor<br />
2 2.2 3.8 26 330 7C260P33-R D 13.0 LI533-H4 2<br />
O<br />
O<br />
26.0<br />
26.0<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
CAP<br />
LI534-H5<br />
LI534-H5<br />
CAP<br />
CAP<br />
Fig. M<br />
X3<br />
COM<br />
10 A<br />
10<br />
10<br />
X1<br />
IGNITOR<br />
X2<br />
LAMP<br />
D/C/<br />
D/D<br />
A/A/<br />
A/A<br />
C/<br />
C/C<br />
E/C/<br />
C<br />
A<br />
A<br />
A<br />
A<br />
A/A<br />
C/C/<br />
C/C<br />
D/<br />
D/D<br />
LAMP<br />
LAMP
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
HID<br />
Metal Halide<br />
New<br />
New<br />
New<br />
New<br />
N<br />
N<br />
N<br />
N<br />
N<br />
N<br />
N<br />
N<br />
N<br />
120/<br />
208/240<br />
277/<br />
347/480<br />
277/<br />
347/480/<br />
120T<br />
120/208/<br />
240/277<br />
347/480/<br />
120T<br />
120/<br />
208/240<br />
277/<br />
347/480<br />
71A64F2<br />
71A64F2-001D<br />
Super<br />
CWA<br />
Cap Catalog<br />
Number<br />
3.0/<br />
8/<br />
818 355<br />
M 8 2.3 4.3 28 400 7C280S40 D 17.0 LI573-H5 15<br />
2.5/1.7<br />
7/5<br />
7.8/4.3 20/10/<br />
940 415<br />
M 2 3.0 5.0 21 480<br />
3.9/3.4<br />
MD2100-030 O 17.5 LI572-H5 ★ 5<br />
10/8<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />
Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-500 includes core & coil with oil-filled capacitor<br />
-510 includes core & coil with welded bracket and oil-filled capacitor<br />
-600 includes core & coil only (no capacitor)<br />
-610 includes core & coil with welded bracket (no capacitor)<br />
• For CWA circuits, figure is operating current.<br />
★ Equipped with an auto-reset thermal protector to prevent ignitor from<br />
overheating in the event of lamp failure.<br />
✝✝ Each ballast requiring an ignitor is furnished as standard with<br />
the Short Range ignitor model shown for use within fixtures.<br />
N If a Long Range ignitor is required for remote mounting, specify<br />
on order. See pages 5-50 to 5-53 for additional information.<br />
Dual rated Class H (180°C) / ADVANCE Class N (200°C) insulation system.<br />
Refer to page 5-3 for additional information.<br />
♦ Special Compact 4-1/4 x 4-3/4 core design<br />
3.31<br />
Input<br />
Volts<br />
B<br />
MAX.<br />
Catalog✝<br />
Number<br />
71A64E2<br />
71A64F2-T<br />
A<br />
3.75<br />
Circuit<br />
Type<br />
Super<br />
CWA<br />
Super<br />
CWA<br />
Watts<br />
Input<br />
4 Holes cleared cleared for for #10<br />
#6 thru-bolts<br />
thru-bolts<br />
4.06<br />
4.50 Fig. 10<br />
(4 1 /2" x 3 3 /4 Reactor Core )<br />
Max•<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
750 Watt Lamp, ANSI Code M149 (Pulse-Start)<br />
71A6490♦<br />
71A64F0-T♦<br />
Super<br />
CWA<br />
Super<br />
CWA<br />
7.0/<br />
20/<br />
812 355<br />
M 8 2.2 4.3 28 400 7C280S40 D 17.0 LI573-H5 15<br />
4.0/3.5 10/10<br />
3.0/<br />
8/<br />
818 355<br />
M 8 2.3 4.3 28 400 7C280S40 D 17.0 LI573-H5 15<br />
2.5/1.7<br />
7/5<br />
71A86E5 CWA 850<br />
7.2/<br />
20/<br />
235<br />
4.1/3.6 10/10<br />
M 8a 3.2 5.3 75 280 7C750S28R D 25.0 LI561-H5 5<br />
71A86F5 CWA 850<br />
3.1/<br />
10/<br />
235<br />
2.5/1.8<br />
10/5<br />
M 8a 3.2 5.1 75 280 7C750S28R D 25.0 LI561-H5 5<br />
875 Watt Lamp, ANSI Code Unassigned (Venture pulse-start lamp)<br />
120/208/<br />
Super<br />
240/277<br />
71A6498♦ CWA<br />
347/480/<br />
Super<br />
120T<br />
71A64F8-T♦ CWA<br />
945 2.8/2.0 415 7/5 M 2 3.0 5.0 21 480 MD2100-030 O 17.5 LI572-H5 ★ 5 E/E<br />
Suffix-510D provides<br />
welded-on mounting<br />
foot bracket.<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Dimensions<br />
Fig<br />
A<br />
B<br />
3 7 /8"<br />
B<br />
MAX.<br />
Suffix-540D provides welded<br />
angle bracket to allow specific<br />
Linear Reactor ballasts to<br />
mount in 400-watt fixtures<br />
designed for standard CWA<br />
ballasts without brackets<br />
(Figure 2).<br />
Bracket Detail<br />
(Fig. 10)<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
4 3 /8" 4 3 /4"<br />
A<br />
4 1 /4"<br />
Dry<br />
or<br />
Oil<br />
44 Holes Holes cleared cleared for for #10<br />
#10 thru-bolts<br />
Fig. 2<br />
(4¹₄”x Fig. 4³₄” 2 core)<br />
(4 1 /4" x 4 3 /4" core)<br />
Total<br />
Weight<br />
(Ibs)<br />
B<br />
MAX.<br />
3 7 /8"<br />
4 1 /4"<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
7.0/4.0/ 20/10/<br />
820 340<br />
M 2 3.0 4.9 28 400 7C280S40 D 17.5 LI573-H5 10<br />
3.5/3.0 10/10<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
820 2.5/1.7 340 7/5 M 2 3.0 4.9 28 400 7C280S40 D 17.5 LI573-H5 10 E/E<br />
750 Watt Lamp, Retrofit for 750 Watt HPS, ANSI Code S111 (Pulse-Start)<br />
E/<br />
E/E<br />
4 3 /8"<br />
5 3 /8" 6 " Fig 8, 8A<br />
Fig. 8<br />
(4 1 /4" x 6" core)<br />
WELDED BRACKET DIMENSIONS<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
2, 10 6.5 1.25 5.75 0.28<br />
3, 8 7.8 2.75 6.13 0.25<br />
8a 7.8 4.50 6.75 0.31<br />
A<br />
U.L. Bench Top<br />
Rise Code 1029<br />
(Pg 5-3)<br />
ADVANCE<br />
Class H<br />
Class N<br />
(180°C)<br />
(200°C)<br />
D/<br />
C/D<br />
E/<br />
E/E<br />
D/D/<br />
D/D<br />
B/<br />
C/C<br />
E/<br />
D/D<br />
E/E/<br />
E/E<br />
A/<br />
A/A<br />
A/<br />
A/A<br />
A/<br />
A/A<br />
A/A<br />
A/A<br />
A/A<br />
A/<br />
A/A<br />
A/<br />
A/A<br />
A/A/<br />
A/A<br />
A/A<br />
8 Holes cleared for<br />
#10 thru-bolts<br />
(4 1 /4” x 6” core)<br />
HID • CORE & COIL<br />
METAL HALIDE<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-29
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
Metal Halide<br />
New<br />
N<br />
NOM<br />
N<br />
NOM<br />
N<br />
N<br />
N<br />
N<br />
N<br />
N<br />
N<br />
NOM<br />
N<br />
Input<br />
Volts<br />
Cap Catalog<br />
Number<br />
1000 Watt Lamp, ANSI Code M47 or H36<br />
120<br />
220<br />
277<br />
71A6502<br />
71A65J2<br />
71A6532<br />
CWA 1080<br />
9.0 9.0<br />
4.95.2<br />
3.94.9<br />
430<br />
20<br />
12<br />
10<br />
A 8 2.6 4.5 24 480 MD2409-100 O 21.0 — —<br />
480 71A6542<br />
71A6542-001<br />
CWA 1080 2.2 430 6 A 8 2.6 4.5 24 480 MD2409-100 O 21.0 — — D<br />
480/120T 71A6542-T CWA 1080 2.2 430 6 A 8 2.6 4.5 24 480 MD2409-100 O 21.0 — — D<br />
120/208/<br />
240/277<br />
120/208/<br />
240/277<br />
120/208/<br />
240/277/<br />
480<br />
120/<br />
277/347<br />
120/<br />
277/347<br />
120/208/<br />
240/277<br />
347/480/<br />
120T<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
71A6592 CWA 1080 9.0/5.2/<br />
4.5/3.9<br />
71A6572-001 CWA 1080 9.0/5.2/<br />
4.5/3.9<br />
71A6552<br />
9.0/5.6/<br />
71A6552-001 CWA 1080 4.7/4.1/<br />
2.4<br />
9.0/<br />
71A65A2 CWA 1080<br />
3.9/3.2<br />
71A65A2-001 CWA 1080<br />
Max•<br />
Input<br />
Current<br />
9.0/<br />
3.9/3.2<br />
71A6590◆ CWA 1070 9.0/5.2/<br />
4.5/3.9<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
430<br />
430<br />
430<br />
430<br />
430<br />
415<br />
Fuse<br />
Rating<br />
(Amps)<br />
20/15/<br />
10/10<br />
20/15/<br />
10/10<br />
22/15/<br />
12/10/<br />
6<br />
20/<br />
10/8<br />
20/<br />
10/8<br />
20/15/<br />
10/10<br />
Wiring<br />
Dia<br />
A<br />
A<br />
A<br />
A<br />
A<br />
A<br />
Dimensions<br />
Fig<br />
A<br />
B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
8 2.6 4.5 24 480 MD2409-100 O 21.0 — — D/B/<br />
B/B<br />
8 2.6 4.5 24 480 MD2409-100 O 21.0 — — D/B/<br />
B/B<br />
D/D/<br />
8 3.0 4.7 24 480 MD2409-100 O 22.0 — — D/C<br />
C<br />
8 2.8 4.5 24 480 MD2409-100 O 21.0 — —<br />
D/<br />
C/C<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
8 2.8 4.5 24 480 MD2409-100 O 21.0 — —<br />
C<br />
B<br />
B<br />
D/<br />
C/C<br />
2 3.4 5.3 24 480 MD2409-100 O 19.0 — — D/D/<br />
D/D<br />
71A65F0-T◆ CWA 1070 3.1/2.2 415 8/6 A 2 3.4 5.3 24 480 MD2409-100 O 19.0 — — D/D<br />
U.L. Bench Top<br />
Rise Code 1029<br />
(Pg 5-3)<br />
ADVANCE<br />
Class H<br />
Class N<br />
(180°C)<br />
(200°C)<br />
A<br />
A<br />
A<br />
A<br />
A<br />
A/A/<br />
A/A<br />
A/A/<br />
A/A<br />
A/A/<br />
A/A<br />
A<br />
A/<br />
A/A<br />
A/<br />
A/A<br />
A/A/<br />
A/A<br />
A/A<br />
N<br />
208/240<br />
120T<br />
7C400P30-R<br />
71A65E6-T CWI 1080 5.3/4.8 440 15/12 P 8 3.5 5.3 20 560<br />
D 25.0 — — C/D<br />
(Two in Series)<br />
A/A<br />
HID • CORE & COIL<br />
METAL HALIDE<br />
New<br />
New<br />
N<br />
N<br />
N<br />
N<br />
1000 Watt Lamp, ANSI Code M141 (Pulse-Start)<br />
120/208/<br />
240/277<br />
347/480/<br />
120T<br />
120/208/<br />
240/277<br />
347/480/<br />
120T<br />
71A6593<br />
71A65F3-T<br />
71A6591◆<br />
71A65F1-T◆<br />
Super<br />
CWA<br />
Super<br />
CWA<br />
Super<br />
CWA<br />
Super<br />
CWA<br />
9.0/5.2/ 20/15/<br />
1080 430<br />
M 8 2.8 4.5 24 480 MD2409-000 O 21.0 LI571-H5 ★ 5<br />
4.5/3.9 10/10<br />
1075 3.2/2.4 430 8/6 M 8 2.8 4.5 24 440 MD2409-000 O 21.0 LI571-H5 ★ 5 D/D<br />
9.0/5.2/ 20/15/<br />
1070 415<br />
M 2 3.4 5.3 24 480 MD2409-000 O 19.0 LI572-H5 ★ 5<br />
4.5/3.9 10/10<br />
1070 3.1/2.2 415 8/6 M 2 3.4 5.3 24 480 MD2409-000 O 19.0 LI572-H5 ★ 5 D/D<br />
D/B/<br />
B/B<br />
D/D/<br />
D/D<br />
A/A/<br />
A/A<br />
A/A<br />
A/A/<br />
A/A<br />
A/A<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001.<br />
Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-500 includes core & coil with oil-filled capacitor<br />
-510 includes core & coil with welded bracket and oil-filled capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
★ Equipped with an auto-reset thermal protector to prevent ignitor from<br />
overheating in the event of lamp failure.<br />
✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range ignitor<br />
model shown for use within fixtures. If a Long Range ignitor is required for remote<br />
mounting, specify on order. See pages 5-50 to 5-53 for additional information.<br />
• For CWA and CWI circuits, figure is operating current.<br />
Canadian replacement/retrofit ballast kit indicated by bold type.<br />
Refer to page 5-10.<br />
N Dual rated Class H (180°C) / ADVANCE Class N (200°C) insulation system.<br />
Refer to page 5-3 for additional information.<br />
◆ Special compact 4-1/4 x 4-3/4 core design.<br />
Certified ballast available for Mexican and Central American markets.<br />
NOM<br />
5-30<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
HID<br />
Metal Halide<br />
N<br />
N<br />
N<br />
NOM<br />
N<br />
N<br />
N<br />
Input<br />
Volts<br />
1500 Watt Lamp, ANSI Code M48<br />
120<br />
220<br />
277<br />
480<br />
120/208/<br />
240/277<br />
120/208/<br />
240/277<br />
120/<br />
277/347<br />
120/<br />
277/347<br />
Catalog✝<br />
Number<br />
71A6702<br />
71A67J2<br />
71A6732<br />
71A6742<br />
71A6742-001<br />
Circuit<br />
Type<br />
CWA<br />
Watts<br />
Input<br />
1605<br />
1605<br />
1605<br />
13.5<br />
7.4<br />
5.9<br />
71A6792 CWA 1605 13.5/7.8/<br />
6.8/5.9<br />
71A6772-001 CWA 1605 13.5/7.8/<br />
6.8/5.9<br />
71A67A2 CWA 1615<br />
71A67A2-001 CWA 1615<br />
Max•<br />
Input<br />
Current<br />
13.5/<br />
5.9/4.8<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001.<br />
Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500 includes core & coil with oil-filled capacitor<br />
-510 includes core & coil with welded bracket and oil-filled capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For CWA circuits, figure is operating current.<br />
✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range ignitor model<br />
shown for use within fixtures. If a Long Range ignitor is required for remote mounting,<br />
specify on order. See pages 5-50 to 5-53 for additional information.<br />
Canadian replacement/retrofit ballast kit indicated by bold type. Refer to page 5-10.<br />
★ Equipped with an auto-reset thermal protector to prevent ignitor from overheating in the<br />
event of lamp failure.<br />
N Dual rated Class H (180°C) / ADVANCE Class N (200°C) insulation system.<br />
Refer to page 5-3 for additional information.<br />
450<br />
450<br />
450<br />
450<br />
30<br />
25<br />
15<br />
30/25/<br />
20/15<br />
30/25/<br />
20/15<br />
30/<br />
15/15<br />
A<br />
B<br />
MAX.<br />
3 7 /8"<br />
4 1 /4"<br />
4 3 /8"<br />
5 3 /8" 6 "<br />
A<br />
8 Holes cleared for<br />
#10 thru-bolts<br />
Fig. 8, 88a<br />
(4 1 /4" x 6" core)<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
8a 4.0 6.0 32 525 MD3202-100 O 29.0 — —<br />
CWA 1625 3.4 450 10 A 8a 4.2 6.2 32 525 MD3202-100 O 31.0 — — E<br />
13.5/<br />
5.9/4.8<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
450<br />
Fuse<br />
Rating<br />
(Amps)<br />
30/<br />
15/15<br />
A<br />
A<br />
A<br />
A<br />
Dimensions<br />
Fig<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
8a 4.1 6.1 32 525 MD3202-100 O 30.0 — — G/E/<br />
E/G<br />
8a 4.1 6.1 32 525 MD3202-100 O 30.0 — — G/E/<br />
E/G<br />
8a 4.1 6.1 32 525 MD3202-100 O 30.0 — —<br />
8a 4.1 6.1 32 525 MD3202-100 O 30.0 — —<br />
1650 Watt Lamp, ANSI Code M112<br />
120/208/<br />
71A6890 CWA 1770 16.0/9.3/ 40/25/<br />
2 Capacitor Set:<br />
465<br />
A 8a 4.4 6.5 34 550<br />
— — H/G<br />
N 240/277<br />
8.0/7.0 20/18<br />
MD1701-200 32.0<br />
G/H<br />
(2) 17 MFD Caps<br />
O<br />
N 347/480 71A68F0 CWA 1770 5.5/4.0 465 15/10 A 8a 4.4 6.5 34 550 [ Connected in Parallel]<br />
32.0 — — I/J<br />
2000 Watt Lamp, ANSI Code M134<br />
N 208/220 71A69H0<br />
CWA 2140 10.5/10.0<br />
2 Capacitor Set:<br />
30/25<br />
43 540<br />
465<br />
8a 4.5 6.0 LI571-H5 ★ I/I<br />
M MD2602-030 and O 43.0<br />
5<br />
MD1701-100<br />
N 240/277 71A69EO<br />
9.0/8.0 25/20<br />
43 540<br />
J/J<br />
Connected in Parallel<br />
3 7 /8"<br />
B<br />
MAX.<br />
4 3 /8" 4 3 /4"<br />
A<br />
4 1 /4"<br />
44 Holes Holes cleared cleared for for #10<br />
#10 thru-bolts<br />
Fig. 2<br />
(4¹₄”x Fig. 4³₄” 2 core)<br />
(4 1 /4" x 4 3 /4" core)<br />
Wiring<br />
Dia<br />
A<br />
B<br />
Mfd<br />
Min<br />
Volt<br />
Total<br />
Weight<br />
(Ibs)<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
U.L. Bench Top<br />
Rise Code 1029<br />
(Pg 5-3)<br />
ADVANCE<br />
Class H<br />
Class N<br />
(180°C)<br />
(200°C)<br />
WELDED BRACKET DIMENSIONS<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
2 6.5 1.25 5.75 0.28<br />
8 7.8 2.75 6.13 0.25<br />
8a 7.8 4.50 6.75 0.31<br />
F<br />
F<br />
F<br />
G/<br />
G/G<br />
G/<br />
G/G<br />
B<br />
B<br />
B<br />
A<br />
C/A/<br />
A/C<br />
C/A/<br />
A/C<br />
C/<br />
C/C<br />
C/<br />
C/C<br />
D/C<br />
C/D<br />
E/F<br />
E/E<br />
F/F<br />
NOM Certified ballast available for Mexican and Central American<br />
markets.<br />
HID • CORE & COIL<br />
METAL HALIDE<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-31
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />
High Pressure Sodium<br />
Input<br />
Volts<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Dimensions<br />
Fig A B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
35 Watt Lamp, ANSI Code S76<br />
R-NPF<br />
120 71A7707<br />
46<br />
R-HPF<br />
71A7707-B R-NPF<br />
120<br />
46<br />
71A7707-001DB R-HPF<br />
1.4<br />
.8<br />
1.4<br />
.8<br />
120<br />
120<br />
3<br />
2<br />
3<br />
2<br />
G<br />
H<br />
9 .7 1.8<br />
9 .7 2.2<br />
—<br />
14<br />
—<br />
14<br />
—<br />
120<br />
—<br />
120<br />
————–<br />
7C140L12<br />
————–<br />
7C140L12<br />
—<br />
D<br />
—<br />
D<br />
1.3<br />
1.5<br />
1.3<br />
1.5<br />
LI551-H4 2 A<br />
Integral<br />
Ignitor<br />
2 A<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D(B).<br />
Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For AR, R and Hybrid circuits, figure is highest of starting, operating or open circuit<br />
currents.<br />
✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range ignitor<br />
model shown for use within fixtures. If a Long Range ignitor is required for remote<br />
mounting, specify on order. See pages 5-50 to 5-53 for additional information.<br />
•• 277V operation requires the 120V reactor ballast and controller plus the 120/277V<br />
auto-transformer listed. Ballast dimensions shown in table are for the reactor ballast<br />
component only. See page 5-54 for auto-transformer specifications and dimensions.<br />
COM<br />
CAP<br />
CAP<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
LAMP<br />
X3 X1<br />
IGNITOR<br />
X2<br />
COM<br />
LAMP<br />
Fig. K<br />
120 V<br />
HID • CORE & COIL<br />
HPS<br />
LINE V<br />
(OPTIONAL) CAP<br />
COM<br />
X3<br />
IGNITOR<br />
X2<br />
X1<br />
LAMP<br />
LAMP<br />
CAP REACTOR<br />
NEUTRAL<br />
LAMP (RED) HV<br />
LAMP<br />
3<br />
CONTROLLER<br />
4<br />
LAMP (BLUE) LV<br />
Fig. R<br />
Fig. G<br />
INTEGRAL<br />
INTEGRATED<br />
IGNITOR IGNITOR BALLAST BALLAST<br />
AUTO TRANSFORMER<br />
277V<br />
120 V<br />
LINE V<br />
LAMP<br />
CAP<br />
REACTOR<br />
3<br />
CONTROLLER<br />
CAP<br />
IGNITOR<br />
LAMP<br />
NEUTRAL/COM<br />
4<br />
COM<br />
LAMP (RED) HV<br />
LAMP<br />
LAMP (BLUE) LV<br />
Fig. H<br />
Fig. S<br />
5-32<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />
HID<br />
High Pressure Sodium<br />
Input<br />
Volts<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
50 Watt Lamp, ANSI Code S68<br />
R-NPF<br />
120 71A7807<br />
62<br />
R-HPF<br />
71A7807-B R-NPF<br />
120<br />
62<br />
71A7807-001DB R-HPF<br />
120/277 71A7801<br />
71A7801-001D<br />
Max •<br />
Input<br />
Current<br />
1.8<br />
1.0<br />
1.8<br />
1.0<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
120<br />
120<br />
Fuse<br />
Rating<br />
(Amps)<br />
5<br />
3<br />
5<br />
3<br />
Wiring<br />
Dia<br />
G<br />
H<br />
Fig<br />
Dimensions<br />
A<br />
B<br />
9 1.0 2.3<br />
9 1.0 2.7<br />
Mfd<br />
—<br />
20<br />
—<br />
20<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
—<br />
120<br />
—<br />
120<br />
Cap Catalog<br />
Number<br />
————–<br />
7C200M12<br />
————–<br />
7C200M12<br />
Dry<br />
or<br />
Oil<br />
—<br />
D<br />
—<br />
D<br />
Total<br />
Weight<br />
(Ibs)<br />
1.8<br />
2.0<br />
1.8<br />
2.0<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
LI551-H4 2 A<br />
Integral<br />
Ignitor<br />
2 A<br />
HX-HPF 66 1.0/.5 125 3/1 K 1 1.0 2.2 5 300 7C050L33 D 3.5 LI551-H4 2 A/A<br />
50 Watt Lamp, ANSI Code S104 (White SON - Philips) (Minimum Starting Temperature –20°F or –30°C)<br />
120 71A7805<br />
Hybrid<br />
<strong>Electronic</strong><br />
68 1.3 120 3 R 9 1.3 2.3 28 120 7C280M12 D 4.0<br />
6C050<br />
Controller<br />
2 A<br />
120/277<br />
••<br />
71A7805(120V)<br />
+<br />
71A9847(120/277V<br />
Auto transformer)<br />
Hybrid<br />
<strong>Electronic</strong><br />
AR<br />
72 0.6 120 3/1<br />
S<br />
9<br />
(2pcs)<br />
6C050<br />
1.3 2.3 28 120 7C280M12 D 8.0 2 A/A<br />
Controller<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D(B).<br />
Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For AR, HX, R, and Hybrid circuits, figure is highest of starting, operating<br />
or open circuit currents.<br />
✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range<br />
ignitor model shown for use within fixtures. If a Long Range ignitor is<br />
required for remote mounting, specify on order. Instant Restrike ignitor also<br />
available (71A7807 and 71A7801 only). See pages 5-50 to 5-53 for additional<br />
information.<br />
• • 277V operation requires the 120V reactor ballast and controller plus the<br />
120/277V auto-transformer listed. Ballast dimensions shown in table are for<br />
the reactor ballast component only. See page 5-54 for auto-transformer<br />
specifications and dimensions.<br />
4 3 /16"<br />
p. 80 o C<br />
rounded.<br />
3 1 /16"<br />
Rectangular Case<br />
White SON Controller<br />
1 11 /16"<br />
HID • CORE & COIL<br />
HPS<br />
B<br />
MAX.<br />
A<br />
2 3 /16"<br />
4 Holes cleared for<br />
#6 thru-bolts<br />
B<br />
MAX.<br />
A<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
2 13 /16"<br />
1 3 /4"<br />
2 3 /16"<br />
2 5 /8" Fig. 9<br />
(2 5 /8" x 2 3 /16 Reactor Core )<br />
2 7 /16"<br />
3 1 /2" 3 15 /16"<br />
Fig. 1<br />
(3" x 4" core)<br />
WELDED BRACKET DIMENSIONS<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
1 5.1 1.00 4.50 0.25<br />
9 4.0 0.75 3.50 0.28<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-33
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />
High Pressure Sodium<br />
Input<br />
Volts<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Dimensions<br />
Fig A B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weigh<br />
t (Ibs)<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
70 Watt Lamp, ANSI Code S62<br />
NOM<br />
120 71A7907<br />
R-NPF<br />
R-HPF<br />
86<br />
2.1<br />
1.3<br />
120<br />
8<br />
3<br />
G<br />
9 1.3 2.5<br />
—<br />
28<br />
—<br />
120<br />
————–<br />
7C280M12<br />
—<br />
D<br />
2.0 LI551-H4 2 A<br />
120<br />
71A7907-B<br />
71A7907-001DB<br />
R-NPF<br />
R-HPF<br />
86<br />
2.1<br />
1.3<br />
120<br />
8<br />
3<br />
H<br />
9 1.3 2.9<br />
—<br />
28<br />
—<br />
120<br />
————–<br />
7C280M12<br />
—<br />
D<br />
2.0<br />
Integral<br />
Ignitor<br />
2 A<br />
120/277<br />
220<br />
480<br />
71A7901<br />
71A79J1<br />
71A7941<br />
HX-HPF<br />
91<br />
91<br />
93<br />
1.4/.7<br />
.8<br />
.4<br />
120<br />
5/2<br />
2<br />
2<br />
K<br />
1<br />
1.5<br />
1.5<br />
1.9<br />
2.8<br />
2.8<br />
3.2<br />
7 300 7C070L33-R D<br />
5.5<br />
5.5<br />
6.5<br />
LI551-H4 2<br />
A/A<br />
A<br />
A<br />
NOM<br />
120/208/<br />
240/277 71A7991 HX-HPF 91 1.4/.9<br />
.8/.7<br />
120<br />
5/3/<br />
2/2<br />
K<br />
1 1.5 3.1 7 300 7C070L33-R D 5.5<br />
LI551-H4<br />
2<br />
B/C/<br />
B/C<br />
120/208/<br />
240/277 71A7971-001D HX-HPF 91 1.4/.9<br />
.8/.7<br />
120<br />
5/3/<br />
2/2<br />
K<br />
1 1.5 3.1 7 300 7C070L33-R D 5.5<br />
LI551-H4 2<br />
B/C/<br />
B/C<br />
120/<br />
277/347 71A79A1 HX-HPF 93 1.4/<br />
.7/.6<br />
120<br />
5/<br />
2/2<br />
K<br />
1 1.5 3.1 7 300 7C070L33-R D 5.5<br />
LI551-H4<br />
2<br />
A/<br />
B/A<br />
120/<br />
277/347<br />
71A79A1-001D HX-HPF 93<br />
1.4/<br />
.7/.6<br />
120<br />
5/<br />
2/2<br />
K<br />
1 1.5 3.1 7 300 7C070L33-R D 5.5<br />
LI551-H4 2<br />
A/<br />
B/A<br />
HID • CORE & COIL<br />
HPS<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D(B).<br />
Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor) (71A7907 Only)<br />
• For HX and R circuits, figure is highest of starting, operating or open circuit<br />
currents.<br />
✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range<br />
ignitor model shown for use within fixtures. If a Long Range ignitor is<br />
required for remote mounting, specify on order. Instant Restrike ignitor also<br />
available (excludes 71A7907-B, 71A79J1 and 71A7941).<br />
See pages 5-50 to 5-53 for additional information.<br />
Canadian replacement/retrofit ballast kit indicated by bold type.<br />
Refer to page 5-10.<br />
NOM Certified ballast available for Mexican and Central American markets.<br />
WELDED BRACKET DIMENSIONS<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
1 5.1 1.00 4.50 0.25<br />
9 4.0 0.75 3.50 0.28<br />
B<br />
MAX.<br />
A<br />
2 3 /16"<br />
4 Holes cleared for<br />
#6 thru-bolts<br />
B<br />
MAX.<br />
A<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
2 13 /16"<br />
1 3 /4"<br />
2 3 /16"<br />
2 5 /8" Fig. 9<br />
(2 5 /8" x 2 3 /16 Reactor Core )<br />
2 7 /16"<br />
3 1 /2" 3 15 /16"<br />
Fig. 1<br />
(3" x 4" core)<br />
5-34<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />
HID<br />
High Pressure Sodium<br />
NOM<br />
Input<br />
Volts<br />
127/220<br />
120/277<br />
120/<br />
208/240<br />
Catalog✝<br />
Number<br />
71A79H8<br />
71A7988<br />
120/240 71A7950<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
70 Watt Lamp, ANSI Code S62<br />
CWA 95<br />
71A79E6 CWI 95<br />
Regulated<br />
Lag<br />
Max •<br />
Input<br />
Current<br />
.8/.5<br />
.9/.4<br />
.9/<br />
.5/.5<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
105<br />
110<br />
Fuse<br />
Rating<br />
(Amps)<br />
2/2<br />
3/1<br />
3/<br />
2/2<br />
Wiring<br />
Dia<br />
M<br />
V<br />
Fig<br />
Dimensions<br />
A<br />
B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Wt.<br />
(Ibs)<br />
1 1.5 2.8 28 170 7C280P30-R D 5.5<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
LI551-J4 5<br />
1 1.6 2.9 24 300 7C240P30 D 5.8 LI551-J4 2<br />
103 .9/.5 125 2.5/1 N 1 2.1 3.3 20 300 7C200P33-R D 6.3 LI551-H4 2 D/B<br />
✝ Ordering information:<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For CWA, CWI and Regulated Lag circuits, figure is operating current.<br />
✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range<br />
ignitor model shown for use within fixtures. If a Long Range ignitor is<br />
required for remote mounting, specify on order. See pages 5-50 to 5-53 for<br />
additional information.<br />
NOM Certified ballast available for Mexican and Central American markets.<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
A/D<br />
A/D<br />
C/<br />
C/D<br />
LINE V<br />
LAMP<br />
LINE V<br />
LAMP<br />
LINE V<br />
LAMP 1<br />
(OPTIONAL)<br />
COM<br />
CAP<br />
X3<br />
IGNITOR<br />
X2<br />
Fig. G<br />
X1<br />
LAMP<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
CAP<br />
CAP<br />
CAP<br />
Fig. M<br />
X3 X1<br />
IGNITOR<br />
X2<br />
COM<br />
LAMP<br />
LINE V<br />
LINE V<br />
COM<br />
X3 X1<br />
IGNITOR<br />
X2<br />
CAP<br />
CAP<br />
LAMP 2<br />
Fig. V<br />
LAMP<br />
HID • CORE & COIL<br />
HPS<br />
INTEGRATED INTEGRAL<br />
IGNITOR BALLAST<br />
LINE V<br />
LAMP 1<br />
CAP<br />
LAMP<br />
LINE V<br />
CAP<br />
IGNITOR<br />
LAMP<br />
LAMP<br />
LINE V<br />
LINE V<br />
LINE V<br />
X3<br />
LAMP 2<br />
X1<br />
X2<br />
IGNITOR<br />
LAMP<br />
COM<br />
CAP<br />
LINE V<br />
LINE V<br />
LINE V<br />
X3 X1<br />
IGNITOR<br />
X2<br />
LAMP<br />
CAP<br />
LINE V<br />
COM<br />
CAP<br />
COM<br />
COM<br />
Fig. H<br />
COM<br />
CAP<br />
Fig. N<br />
Fig. K<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-35
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />
High Pressure Sodium<br />
Input<br />
Volts<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Dimensions<br />
Fig A B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Wt.<br />
(Ibs)<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
100 Watt Lamp, ANSI Code S54<br />
120 71A8007<br />
R-NPF<br />
R-HPF<br />
115<br />
3.1<br />
1.8<br />
120<br />
10<br />
5<br />
G<br />
9 1.5 2.7<br />
—<br />
36<br />
—<br />
120<br />
————–<br />
7C360M12<br />
—<br />
D<br />
2.5<br />
2.8<br />
LI551-H4 2 A<br />
120<br />
71A8007-B<br />
71A8007-001DB<br />
R-NPF<br />
R-HPF<br />
115<br />
3.1<br />
1.8<br />
120<br />
10<br />
5<br />
H<br />
9 1.5 2.7<br />
—<br />
36<br />
—<br />
120<br />
————–<br />
7C360M12<br />
—<br />
D<br />
2.5<br />
2.8<br />
Integral<br />
Ignitor<br />
2 A/A<br />
120/277<br />
220<br />
71A8001<br />
71A80J1<br />
HX-HPF 130<br />
2.2/.9<br />
1.2<br />
120<br />
7/3<br />
3<br />
K<br />
1 2.0 3.3 10 280 7C100M33-R D 7.2 LI551-H4 2<br />
C/C<br />
B<br />
71A8041<br />
480<br />
HX-HPF 130 .6 120 3<br />
71A8041-001D K 1 2.3 3.6 10 280 7C100M33-R D 7.5 LI551-H4 2 E<br />
120/208/<br />
240/277 71A8091 HX-HPF 130 2.2/1.3/ 7/5/<br />
D/F/<br />
120<br />
K 1 2.0 3.6 10 280 7C100M33-R D 7.2 LI551-H4 2<br />
1.1/.9<br />
3/3<br />
D/D<br />
120/208/<br />
240/277 71A8071-001D HX-HPF 130 2.2/1.3/ 7/5/<br />
D/F/<br />
120<br />
K 1 2.0 3.6 10 280 7C100M33-R D 7.2 LI551-H4 2<br />
1.1/.9<br />
3/3<br />
D/D<br />
120/<br />
277/347 71A80A1 HX-HPF 130 2.2/<br />
7/<br />
C/<br />
120<br />
K 1 2.3 3.6 10 280 7C100M33-R D 7.5 LI551-H4 2<br />
.9/.7<br />
3/3<br />
C/D<br />
120/<br />
277/347 71A80A1-001D HX-HPF 130 2.2/<br />
7/<br />
C/<br />
120<br />
K 1 2.3 3.6 10 280 7C100M33-R D 7.5 LI551-H4 2<br />
.9/.7<br />
3/3<br />
C/D<br />
100 Watt Lamp, ANSI Code S105, (White SON-Philips) (Minimum Starting Temperature –20°F or –30°C)<br />
Hybrid<br />
6C100<br />
120 71A8005<br />
120 2.2 120 5 R 9 2.0 3.2 45 120 7C450P12 D 5.5<br />
2 A<br />
<strong>Electronic</strong><br />
Controller<br />
HID • CORE & COIL<br />
HPS<br />
120/277<br />
••<br />
71A8005(120V)<br />
+<br />
71A9876(120/277V<br />
Auto transformer)<br />
Hybrid<br />
<strong>Electronic</strong><br />
AR<br />
125 1.0 120 5/3<br />
9<br />
(2pcs)<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -<br />
001D(B). Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film<br />
capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor) (71A8007 Only)<br />
• For AR, HX, R and Hybrid circuits, figure is highest of starting,<br />
operating or open circuit currents.<br />
✝✝ Each ballast requiring an ignitor is furnished standard with the<br />
Short Range ignitor model shown for use within fixtures. If a Long<br />
Range ignitor is required for remote mounting, specify on order.<br />
Instant Restrike ignitor also available (excludes 71A8005, 71A8007-B,<br />
71A80J1 and 71A8041). See pages 5-50 to 5-53 for additional<br />
information.<br />
•• 277V operation requires the 120V reactor ballast and controller<br />
plus the 120/277V auto-transformer listed. Ballast dimensions<br />
shown in table are for the reactor ballast component only. See<br />
page 5-54 for auto-transformer specifications and dimensions.<br />
Canadian replacement/retrofit ballast kit indicated by bold type.<br />
Refer to page 5-10.<br />
S<br />
LINE V<br />
(OPTIONAL)<br />
CAP<br />
LINE V<br />
COM<br />
2.0 3.2 45 120 7C450P12 D 9.5<br />
COM<br />
CAP<br />
IGNITOR<br />
Fig. H<br />
X3<br />
IGNITOR<br />
X2<br />
Fig. G<br />
INTEGRAL<br />
INTEGRATED<br />
IGNITOR BALLAST<br />
LAMP<br />
X1<br />
LAMP<br />
LAMP<br />
LAMP<br />
4 3 /16"<br />
COM<br />
p. 80 o C<br />
rounded.<br />
CAP<br />
3 1 /16"<br />
CAP<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
6C100<br />
Controller<br />
Fig. K<br />
LAMP<br />
X3<br />
IGNITOR<br />
X2<br />
COM<br />
1 11 /16"<br />
2 A/A<br />
X1<br />
LAMP<br />
Rectangular<br />
Case<br />
White SON<br />
Controller<br />
5-36<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />
HID<br />
NOM<br />
NOM<br />
NOM LL<br />
Input<br />
Volts<br />
Catalog<br />
Number †<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
100 Watt Lamp, ANSI Code S54<br />
120/277<br />
127/220<br />
480/120T<br />
120/240<br />
120/277<br />
240/480<br />
71A8088<br />
71A80H8<br />
71A8048-T<br />
71A8050<br />
71A8080<br />
71A8060<br />
CWA 138<br />
Regulated<br />
Lag<br />
138<br />
Max •<br />
Input<br />
Current<br />
1.2/.5<br />
1.1/.7<br />
.3<br />
1.2/.6<br />
1.2/.6<br />
.6/.3<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
115<br />
120<br />
Fuse<br />
Wiring<br />
Rating<br />
Dia<br />
(Amps)<br />
3/2<br />
3/2<br />
1<br />
3/<br />
2/2<br />
3/2<br />
3/2<br />
1.5/1<br />
Dimensions<br />
Fig A B Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
High Pressure Sodium<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(lbs)<br />
Ignitor ††<br />
(Page 5-50 to 5-53)<br />
Max<br />
Dist<br />
Part<br />
To<br />
Number<br />
Lamp<br />
(ft)<br />
M 1 2.0 3.3 34 170 7C340P24 D 7.5 LI551-J4 5<br />
120/<br />
208/240 71A80EG CWI 130 1.2/<br />
.7/.6<br />
110<br />
V 1 2.1 3.4 35 170 7C350P24 D 6.8 LI551-J4 2<br />
120/240 71A8056 CWI 130 1.3/0.7 108 3/2 V 1 2.1 3.4 35 170 7C350P24 D 6.8 LI551-J4 2 C/B<br />
230 71A80J8 CWA 136 0.7 118 2 M 1 2.0 3.3 34 170 7C350P24 D 7.5 LI551-J4 5 E<br />
220/240 7180J9 CWA 124 0.6/0.6 117 2/2 M 1 2.8 4.6 34 240 7C340P24 D 10.5 LI551-J4 5 A/A<br />
✝ Ordering information:<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For CWA, CWI and Regulated Lag circuits, figure is operating current.<br />
✝✝ Each ballast requiring an ignitor is furnished standard with the Short Range ignitor model shown<br />
for use within fixtures. If a Long Range ignitor is required for remote mounting, specify on order.<br />
See pages 5-50 to 5-53 for additional information.<br />
NOM Certified ballast available for Mexican and Central American markets.<br />
LL Special High Efficiency/Low Loss Magnetic ballast<br />
N 2 1.4 3.0 16 330 7C160M33 D 8.5 LI551-H4 2<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
F/F<br />
E/D<br />
E<br />
C/<br />
C/B<br />
A/A<br />
A/A<br />
A/A<br />
4 Holes cleared for<br />
120 V<br />
CAP<br />
REACTOR<br />
B<br />
MAX.<br />
A<br />
#10 thru-bolts<br />
NEUTRAL<br />
LAMP (RED) HV<br />
LAMP<br />
3<br />
CONTROLLER<br />
4<br />
LAMP (BLUE) LV<br />
Fig. R<br />
2 7 /16"<br />
3 1 /2" 3 15 /16"<br />
2 13 /16"<br />
Fig. 1<br />
(3" x 4" core)<br />
B<br />
MAX.<br />
A<br />
2 3 /16"<br />
4 Holes cleared for<br />
#6 thru-bolts<br />
HID • CORE & COIL<br />
HPS<br />
AUTO TRANSFORMER<br />
277V<br />
120 V<br />
REACTOR<br />
CAP<br />
NEUTRAL/COM<br />
LAMP (RED) HV<br />
3<br />
4<br />
CONTROLLER<br />
LINE V<br />
LINE V<br />
LINE V<br />
LAMP 1<br />
X3 X1<br />
IGNITOR<br />
X2<br />
LAMP<br />
3 /4"<br />
2 3 /16"<br />
2 5 /8" Fig. 9<br />
(2 5 /8" x 2 3 /16 Reactor Core )<br />
LAMP<br />
Fig. S<br />
LAMP (BLUE) LV<br />
COM<br />
CAP<br />
Fig. V<br />
CAP<br />
LAMP 2<br />
LINE V<br />
LAMP<br />
LINE V<br />
LAMP 1<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
CAP<br />
CAP<br />
CAP<br />
Fig. M<br />
X3 X1<br />
IGNITOR<br />
X2<br />
COM<br />
LAMP<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
X3 X1<br />
IGNITOR<br />
X2<br />
LAMP 2<br />
CAP<br />
CAP<br />
CAP<br />
Fig. N<br />
LAMP<br />
WELDED BRACKET DIMENSIONS<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
1 5.1 1.00 4.50 0.25<br />
2 6.5 1.25 5.75 0.28<br />
9 4.0 0.75 3.50 0.28<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-37
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />
High Pressure Sodium<br />
Input<br />
Volts<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Dimensions<br />
Fig A B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
150 Watt Lamp, ANSI Code S55 (55-Volt Arc Tube)<br />
120<br />
120<br />
71A8107<br />
71A8107-B<br />
71A8107-001DB<br />
R-NPF<br />
R-HPF<br />
R-NPF<br />
R-HPF<br />
170<br />
170<br />
4.5<br />
2.4<br />
4.5<br />
2.4<br />
120<br />
120<br />
15<br />
8<br />
15<br />
8<br />
G<br />
H<br />
9<br />
9<br />
2.0<br />
2.0<br />
3.3<br />
3.6<br />
—<br />
55<br />
—<br />
55<br />
—<br />
120<br />
—<br />
120<br />
––––––––<br />
7C550P12<br />
––––––––<br />
7C550P12<br />
—<br />
D<br />
—<br />
D<br />
3.5<br />
4.0<br />
3.5<br />
4.0<br />
LI551-H4<br />
Integral<br />
Ignitor<br />
2<br />
2<br />
A<br />
A<br />
120/277<br />
220<br />
277<br />
71A8102<br />
71A81J2<br />
71A8132<br />
HX-HPF 188<br />
2.8/1.3<br />
1.5<br />
1.3<br />
120<br />
10/4<br />
4<br />
4<br />
K<br />
1 2.6 3.8 14 280 7C140M33-R D 7.5 LI551-H4 2<br />
E/E<br />
C<br />
D<br />
480<br />
71A8142<br />
71A8142-001D<br />
HX-HPF 188 0.7<br />
480/120T 71A8142-T HX-HPF 188 0.7<br />
120/208/<br />
240/277 71A8192 HX-HPF 188 2.8/1.6/<br />
1.4/1.3<br />
120<br />
120<br />
120<br />
2<br />
2<br />
10/5/<br />
5/4<br />
K<br />
K<br />
K<br />
1 3.0 4.3 14 280 7C140M33-R D 9.0<br />
1 3.0 4.3 14 280 7C140M33-R D 9.0<br />
LI551-H4 2<br />
LI551-H4 2<br />
1 2.6 3.8 14 280 7C140M33-R D 7.5 LI551-H4 2<br />
E<br />
E<br />
E/D/<br />
E/D<br />
120/208/<br />
240/277 71A8172-001D HX-HPF 188 2.8/1.6/<br />
1.4/1.3<br />
120<br />
10/5/<br />
5/5<br />
K<br />
1 2.6 3.8 14 280 7C140M33-R D 7.5 LI551-H4 2<br />
E/D/<br />
E/D<br />
120/<br />
277/347 71A81A2 HX-HPF 188 2.8/<br />
1.3/.9<br />
120<br />
10/<br />
4/3<br />
K<br />
1 2.6 3.8 14 280 7C140M33-R D 7.5 LI551-H4 2<br />
D/<br />
D/D<br />
120/<br />
277/347 71A81A2-001D HX-HPF 188 2.8/<br />
1.3/.9<br />
120<br />
10/<br />
4/3<br />
K<br />
1 2.6 3.8 14 280 7C140M33-R D 7.5 LI551-H4 2<br />
D/<br />
D/D<br />
HID • CORE & COIL<br />
HPS<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D(B).<br />
Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor) (71A8107 Only)<br />
• For HX and R circuits, figure is highest of starting, operating or open circuit currents.<br />
✝✝ Each ballast requiring an ignitor is furnished as standard with the Short Range ignitor<br />
model shown for use within fixtures. If a Long Range ignitor is required for remote<br />
mounting, specify on order. Instant Restrike ignitor also available (excludes<br />
71A8107-B, 71A81J2, 71A8132 and 71A8142). See pages 5-50 to 5-53 for<br />
additional information.<br />
Canadian replacement/retrofit ballast kit indicated by bold type.<br />
Refer to page 5-10.<br />
LINE V<br />
(OPTIONAL) CAP<br />
COM<br />
CAP<br />
LINE V<br />
LINE V<br />
CAP<br />
LINE V<br />
COM<br />
LINE V<br />
COM<br />
LAMP<br />
X3<br />
X1<br />
IGNITOR<br />
X2<br />
Fig. G<br />
LAMP<br />
X3 X1<br />
IGNITOR<br />
X2<br />
COM<br />
LAMP<br />
LAMP<br />
Fig. K<br />
INTEGRAL<br />
INTEGRATED<br />
IGNITOR BALLAST<br />
IGNITOR BALLAST<br />
LINE V<br />
LAMP<br />
CAP<br />
IGNITOR<br />
LAMP<br />
COM<br />
Fig. H<br />
5-38<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />
HID<br />
High Pressure Sodium<br />
Input<br />
Volts<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
150 Watt Lamp, ANSI Code S55 (55-Volt Arc Tube)<br />
120/277<br />
127/220<br />
480<br />
71A8188<br />
71A81H8<br />
71A8148<br />
CWA 190<br />
1.7/.7<br />
1.6/.9<br />
.5<br />
110<br />
5/3<br />
4/2<br />
1<br />
Wiring<br />
Dia<br />
M<br />
Fig<br />
1<br />
Dimensions<br />
A<br />
2.8<br />
2.8<br />
2.5<br />
B<br />
4.1<br />
4.1<br />
3.8<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
55 170 7C550P24 D<br />
Total<br />
Weight<br />
(Ibs)<br />
8.5<br />
8.5<br />
8.0<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
LI551-J4 10<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
E/D<br />
D/C<br />
E<br />
120/<br />
208/240<br />
71A81E6 CWI 190<br />
1.7/<br />
1.1/.8<br />
105<br />
5/<br />
3/3<br />
V<br />
1 2.6 4.0 52 240 7C520P24 D 8.5 LI551-J4 2<br />
E/<br />
E/D<br />
120/240<br />
120/277<br />
240/480<br />
71A8150<br />
71A8180<br />
71A8160<br />
Regulated<br />
Lag 196<br />
1.7/.9<br />
1.7/.8<br />
.9/.4<br />
120<br />
5/3<br />
5/2<br />
3/1<br />
N<br />
2 2.0 3.5 16 400 7C160P40 D 12.0 LI551-H4 2<br />
B/B<br />
B/A<br />
B/B<br />
150 Watt Lamp, ANSI Code S56 (100-Volt Arc Tube)<br />
480 71A8146-001D CWA 188 0.5 180 2 M 1 2.5 3.8 20 280 7C200P33-R D 8.5 LI501-H4 2 B<br />
120/208/<br />
240/277 71A8196 CWA 188 1.7/1.0<br />
.9/.8<br />
120/208/<br />
240/277 71A8176-001D CWA 188 1.7/1.0<br />
.9/.8<br />
180<br />
180<br />
5/3/<br />
3/3<br />
5/3/<br />
3/3<br />
M<br />
M<br />
1 2.5 4.1 20 280 7C200P33-R D 8.5<br />
1 2.5 4.1 20 280 7C200P33-R D 8.5<br />
LI501-H4 2<br />
LI501-H4 2<br />
NOM LL 220/240 71A81J9 CWA 170 0.8/0.7 111 2/2 M 2 2.5 3.8 60 240 7C600P24 D 13.5 LI551-J4 2 A/A<br />
E/D/<br />
C/C<br />
E/D/<br />
C/C<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D. Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For CWA, CWI and Regulated Lag circuits, figure is operating current.<br />
✝✝ Each ballast requiring an ignitor is furnished as standard with the Short Range ignitor model shown<br />
for use within fixtures. If a Long Range ignitor is required for remote mounting, specify on order. See<br />
pages 5-50 to 5-53 for additional information.<br />
NOM Certified ballast available for Mexican and Central American markets.<br />
LL Special High Efficiency/Low Loss Magnetic ballast<br />
1 3 /4"<br />
B<br />
MAX.<br />
B<br />
MAX.<br />
2 3 /16"<br />
A<br />
2 3 /16"<br />
A<br />
4 Holes cleared for<br />
#6 thru-bolts<br />
2 5 /8" Fig. 9<br />
(2 5 /8" x 2 3 /16 Reactor Core )<br />
4 1 /4"<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
HID • CORE & COIL<br />
HPS<br />
4 Holes cleared for<br />
LINE V<br />
LINE V<br />
LINE V<br />
LAMP 1<br />
X3<br />
X1<br />
X2<br />
IGNITOR<br />
LAMP<br />
B<br />
MAX.<br />
A<br />
2 13 /16"<br />
#10 thru-bolts<br />
3 7 /8"<br />
4 3 /8" 4 3 /4"<br />
Fig. 2<br />
(4 1 /4" x 4 3 /4" core)<br />
LAMP 2<br />
LINE V<br />
CAP<br />
COM<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
CAP<br />
CAP<br />
CAP<br />
Fig. N<br />
LAMP<br />
X3 X1<br />
IGNITOR<br />
X2<br />
CAP<br />
CAP<br />
COM<br />
LAMP<br />
2 7 /16"<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
3 1 /2" 3 15 /16"<br />
LAMP 1<br />
CAP<br />
CAP<br />
Fig. 1<br />
(3" x 4" core)<br />
X3<br />
IGNITOR<br />
X1<br />
X2<br />
LAMP 2<br />
LAMP<br />
WELDED BRACKET DIMENSIONS<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
1 5.1 1.00 4.50 0.25<br />
2 6.5 1.25 5.75 0.28<br />
9 4.0 0.75 3.50 0.28<br />
Fig. M<br />
Fig. V<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-39
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />
High Pressure Sodium<br />
Input<br />
Volts<br />
Catalog<br />
Number †<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Wiring<br />
Rating<br />
Dia<br />
(Amps)<br />
Dimensions<br />
Fig A B Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(lbs)<br />
Ignitor ††<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
200 Watt Lamp, ANSI Code S66<br />
71A8940<br />
480<br />
71A8940-001D<br />
120/208/<br />
240/277 71A8990 CWA 240 2.2/1.3<br />
1.1/1.0<br />
120/208/<br />
240/277 71A8970-001D CWA 240 2.2/1.3<br />
1.1/1.0<br />
CWA 240 .6 185 2 M 2 1.2 3.0 28 280 7C280P30-R D 8.5 LI501-H4 2 C<br />
185<br />
185<br />
6/4/<br />
3/3<br />
6/4/<br />
3/3<br />
M 2 1.2 3.0 28 280 7C280P30-R D 8.5 LI501-H4 2<br />
M 2 1.2 3.0 28 280 7C280P30-R D 8.5 LI501-H4 2<br />
480 71A8941 CWA 250 .6 195 2 M 1 3.0 4.2 24 280 7C240P30 D 8.5 LI501-H4 2 J<br />
120/208/<br />
240/277 71A8991 CWA 250 2.4/1.4<br />
1.2/1.0<br />
195<br />
8/5/<br />
5/3<br />
M 1 3.0 4.2 24 280 7C240P30 D 8.5 LI501-H4 2<br />
120/208/<br />
2.1/1.2<br />
6/5/<br />
C/B/B/<br />
240/277/ 71A8950 CWA 242 1.1/1.0 199<br />
M 2 1.4 3.0 28 280 7C280P30-R D 9.0 LI501-H4 2<br />
3/3/2<br />
B/B<br />
480<br />
0.6<br />
120/240 71A8954<br />
Regulated<br />
Lag<br />
255 2.2/1/1 225 6/3 N 2 2.3 3.9 18 400 7C180P40-R D 14.0 LI501-H4 2 C<br />
240/480 71A8964<br />
Regulated<br />
Lag<br />
255 1.1/.7 225 3/2 N 2 2.3 3.9 18 400 7C180P40-R D 14.0 LI501-H4 2 C<br />
E/D/<br />
D/C<br />
E/D/<br />
D/C<br />
H/G/<br />
H/I<br />
HID • CORE & COIL<br />
HPS<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />
Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For CWA and Regulated Lag circuits, figure is operating current.<br />
✝✝ Each ballast requiring an ignitor is furnished as standard with the Short Range ignitor model shown for<br />
use within fixtures. If a Long Range ignitor is required for remote mounting, specify on order. See<br />
pages 5-50 to 5-53 for additional information.<br />
◆ Special compact 3 x 4 core design. Note Bench Top Rise Codes in last column.<br />
B<br />
MAX.<br />
A<br />
4 1 /4"<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
LINE V<br />
LINE V<br />
LINE V<br />
LAMP 1<br />
X3 X1<br />
X2<br />
IGNITOR<br />
LAMP<br />
B<br />
MAX.<br />
A<br />
2 13 /16"<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
3 7 /8"<br />
4 3 /8" 4 3 /4"<br />
Fig. 2<br />
(4 1 /4" x 4 3 /4" core)<br />
LAMP 2<br />
LINE V<br />
CAP<br />
CAP<br />
COM<br />
CAP<br />
Fig. N<br />
2 7 /16"<br />
3 1 /2" 3 15 /16"<br />
Fig. 1<br />
(3" x 4" core)<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
CAP<br />
CAP<br />
CAP<br />
Fig. M<br />
LAMP<br />
X3 X1<br />
IGNITOR<br />
X2<br />
COM<br />
LAMP<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
LAMP 1<br />
X3 X1<br />
IGNITOR<br />
X2<br />
CAP<br />
CAP<br />
LAMP 2<br />
LAMP<br />
WELDED BRACKET DIMENSIONS<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
1 5.1 1.00 4.50 0.25<br />
2 6.5 1.25 5.75 0.28<br />
3 7.8 2.75 6.13 0.25<br />
Fig. V<br />
5-40<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />
HID<br />
NOM<br />
Input<br />
Volts<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
250 Watt Lamp, ANSI Code S50<br />
120<br />
127/220<br />
277<br />
480<br />
480/120T<br />
71A8201<br />
71A82H1<br />
71A8231<br />
71A8241<br />
71A8241-001D<br />
71A8241-T<br />
CWA 295<br />
CWA<br />
CWA<br />
310<br />
310<br />
Max •<br />
Input<br />
Current<br />
2.5<br />
2.5/1.5<br />
1.1<br />
.7<br />
.7<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
185<br />
185<br />
185<br />
Fuse<br />
Rating<br />
(Amps)<br />
7<br />
7/4<br />
3<br />
2<br />
2<br />
Wiring<br />
Dia<br />
M<br />
M<br />
M<br />
Dimensions<br />
Fig<br />
A<br />
B<br />
Mfd<br />
High Pressure Sodium<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
2 1.8 3.5 35 240 7C350P24 D 11.0 LI501-H4 2<br />
2<br />
2<br />
1.8<br />
1.8<br />
3.5<br />
3.5<br />
35<br />
35<br />
240<br />
240<br />
7C350P24<br />
7C350P24<br />
D<br />
D<br />
11.0<br />
11.0<br />
LI501-H4<br />
LI501-H4<br />
2<br />
2<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
A<br />
D/C<br />
B<br />
B<br />
B<br />
120/277<br />
71A8281 CWA 295 2.5/1.1 185 7/3 M 2 1.8 3.5 35 240 7C350P24 D 11.0 LI501-H4 2 B/B<br />
NOM<br />
120/208/<br />
240/277<br />
71A8291 CWA 295<br />
2.5/1.5/<br />
1.3/1.1<br />
185<br />
7/4/<br />
4/3<br />
M<br />
2 1.8 3.5 35 240 7C350P24 D 11.0 LI501-H4 2<br />
B/A/<br />
B/B<br />
120/208/<br />
240/277 71A8271-001D CWA 295 2.5/1.5/<br />
1.3/1.1<br />
185<br />
7/4/<br />
4/3<br />
M<br />
2 1.8 3.5 35 240 7C350P24 D 11.0 LI501-H4 2<br />
B/A/<br />
B/B<br />
120/208/<br />
240/277/<br />
480<br />
2.6/1.5/<br />
71A8251<br />
71A8251-001D CWA 300 1.3/1.2/<br />
.7<br />
185<br />
10/4/<br />
4/3/<br />
2<br />
M<br />
2 2.0 3.6 35 240 7C350P24 D 12.0 LI501-H4 2<br />
B/B/<br />
B/B/<br />
B<br />
120/<br />
277/347 71A82A1 CWA 295 2.7/<br />
1.2/.9<br />
185<br />
7/<br />
3/2<br />
M<br />
2 2.0 3.6 35 240 7C350P24 D 11.5 LI501-H4 2<br />
C/<br />
C/B<br />
120/<br />
277/347 71A82A1-001D CWA 295 2.7/<br />
1.2/.9<br />
185<br />
7/<br />
3/2<br />
M<br />
2 2.0 3.6 35 240 7C350P24 D 11.5 LI501-H4 2<br />
C/<br />
C/B<br />
120/<br />
208/240 71A82E6 CWI 300 2.8/<br />
1.6/1.4<br />
190<br />
8/<br />
5/5<br />
V<br />
2 1.9 3.8 28 300 7C280P30-R D 11.0 LI501-J4 2<br />
D/<br />
C/C<br />
LL<br />
220/240 71A82J9 CWA 285 1.4/1.3 188 4/4 M 2 1.8 3.4 34 240 7C340P24 D 11.0 LI501-H4 5 A/A<br />
120/208/<br />
240/277<br />
120/240 71A8250<br />
240/480 71A8260<br />
120/277 71A8280<br />
71A8296 CWI 300<br />
Regulated<br />
Lag<br />
Regulated<br />
Lag<br />
Regulated<br />
Lag<br />
2.6/1.5/<br />
1.3/1.2<br />
190<br />
7/5/<br />
3/3<br />
V<br />
2 1.9 3.5 28 300 7C280P30R D 11.0 LI501J4 5<br />
310 2.7/1.4 220 8/4 N 3 2.4 4.0 16 480 MD1606-000 O 18.0 LI501-H4 2 C/C<br />
310 1.4/.7 220 4/2 N 3 2.4 4.0 16 480 MD1606-000 O 18.0 LI501-H4 2 C/C<br />
310 2.7/1.2 220 8/3 N 3 2.4 4.0 16 480 MD1606-000 O 18.0 LI501-H4 2 C/C<br />
E/C/<br />
C/C<br />
HID • CORE & COIL<br />
HPS<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />
Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For CWA circuits, figure is operating current.<br />
✝✝ Each ballast requiring an ignitor is furnished as standard with the Short<br />
Range ignitor model shown for use within fixtures. If a Long Range ignitor<br />
is required for remote mounting, specify on order. See pages 5-50 to 5-53<br />
for additional information.<br />
Canadian replacement/retrofit ballast kit indicated by bold type.<br />
Refer to page 5-10.pages 5-50 to 5-53 for additional information.<br />
NOM Certified ballast available for Mexican and Central American markets.<br />
LL Special High Efficiency/Low Loss Magnetic ballast<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-41
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />
High Pressure Sodium<br />
Input<br />
Volts<br />
Catalog<br />
Number †<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
310 Watt Lamp, ANSI Code S67<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Wiring<br />
Rating<br />
Dia<br />
(Amps)<br />
Dimensions<br />
Fig A B Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(lbs)<br />
Ignitor ††<br />
(Page 5-50 to 5-53)<br />
Max<br />
Dist<br />
Part<br />
To<br />
Number<br />
Lamp<br />
(ft)<br />
480 71A8341 CWA 365 0.9 175 3 M 2 2.2 3.8 45 280 7C450P30-R D 13.5 LI501-H4 2 D<br />
120/208/<br />
240/277 71A8391 CWI 365 3.4/1.9/<br />
1.7/1.4<br />
120/208/<br />
240/277 71A8371-001D CWA 365 3.4/1.9/<br />
1.7/1.4<br />
120/240<br />
240/480<br />
71A8350<br />
71A8360<br />
Regulated<br />
Lag<br />
380<br />
120/208/<br />
240/277/ 71A8351 CWA 367<br />
480<br />
3.3/1.7<br />
1.7/.9<br />
3.2/1.7/1<br />
.6/1.4/.8<br />
175<br />
175<br />
210<br />
183<br />
8/5/<br />
5/5<br />
8/5/<br />
5/5<br />
9/4<br />
4/3<br />
8/5/4/<br />
4/2<br />
M 2 2.2 4.1 45 280 7C450P30-R D 13.5 LI501-H4 2<br />
M 2 2.2 4.1 45 280 7C450P30-R D 13.5 LI501-H4 2<br />
N 3 2.8 4.5 17 525 MD1701-000 D 21.0 LI501-H4 2<br />
M 2 2.5 4.1 45 280 7C450P30-R D 14.0 LI501-H4 2<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
D/D/<br />
D/B<br />
D/C/<br />
D/B<br />
C/B<br />
C/B<br />
C/A/B/<br />
B/B<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />
Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-500 includes core & coil with oil-filled capacitor<br />
-510 includes core & coil with welded bracket and oil-filled capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For CWA and Regulated Lag circuits, figure is operating current.<br />
✝✝ Each ballast requiring an ignitor is furnished as standard with the Short Range ignitor model<br />
shown for use within fixtures. If a Long Range ignitor is required for remote mounting,<br />
specify on order. See pages 5-50 to 5-53 for additional information.<br />
3 7 /8"<br />
B<br />
MAX.<br />
4 3 /8" 4 3 /4"<br />
A<br />
4 1 /4"<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
Fig. 2<br />
(4 1 /4" x 4 3 /4" core)<br />
HID • CORE & COIL<br />
HPS<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
LAMP 1<br />
X3 X1<br />
IGNITOR<br />
X2<br />
LAMP 2<br />
CAP<br />
CAP<br />
LAMP<br />
COM<br />
CAP<br />
Fig. N<br />
LINE V<br />
LAMP 1<br />
LINE V<br />
LINE V<br />
X3 X1<br />
IGNITOR<br />
X2<br />
LAMP<br />
COM<br />
CAP<br />
CAP<br />
LAMP 2<br />
Fig. V<br />
LINE V<br />
LAMP<br />
LINE V<br />
WELDED BRACKET DIMENSIONS<br />
LINE V<br />
LINE V<br />
COM<br />
CAP<br />
CAP<br />
CAP<br />
Fig. M<br />
X3 X1<br />
IGNITOR<br />
X2<br />
COM<br />
LAMP<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
2 6.5 1.25 5.75 0.28<br />
3 7.8 2.75 6.13 0.25<br />
5-42<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />
HID<br />
High Pressure Sodium<br />
NOM<br />
Input<br />
Volts<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
400 Watt Lamp, ANSI Code S51<br />
120 71A8403<br />
127/220 71A84H3 CWA 457<br />
277 71A8433<br />
Max •<br />
Input<br />
Current<br />
3.8<br />
3.7/2.1<br />
1.7<br />
120/208/<br />
71A8453<br />
3.9/2.2/<br />
240/277/<br />
480<br />
71A8453-001D CWA 465 1.9/1.7/<br />
1.0<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
190<br />
195<br />
Fuse<br />
Rating<br />
(Amps)<br />
10<br />
5<br />
5<br />
10/6/<br />
5/5/<br />
3<br />
Wiring<br />
Dia<br />
M<br />
Fig<br />
Dimensions<br />
A<br />
B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
2 2.3 4.0 55 240 7C550P24 D 13.5 LI501-H4 2<br />
71A8443<br />
480<br />
CWA 464 1.0 190 3 M 2 2.6 4.3 55 240 7C550P24 D 15.0 LI501-H4 2<br />
71A8443-001D<br />
480/120T 71A8443-T CWA 464 1.0 190 3 M 2 2.6 4.3 55 240 7C550P24 D 15.0 LI501-H4 2<br />
120/208/<br />
240/277 71A8493 CWA 464 3.8/2.2/<br />
1.9/1.7<br />
120/208/<br />
240/277 71A8473-001D CWA 464 3.8/2.2/<br />
1.9/1.7<br />
120/<br />
277/347 71A84A3 CWA 464 3.8/<br />
1.7/1.3<br />
120/<br />
277/347 71A84A3-001D CWA 464 3.8/<br />
1.7/1.3<br />
190<br />
190<br />
190<br />
190<br />
10/8/<br />
5/5<br />
10/8/<br />
5/5<br />
10/<br />
5/5<br />
10/<br />
5/5<br />
M<br />
M<br />
M<br />
M<br />
M<br />
2 2.3 4.0 55 240 7C550P24 D 13.5 LI501-H4 2<br />
2 2.3 4.0 55 240 7C550P24 D 13.5 LI501-H4 2<br />
2 2.7 4.4 55 240 7C550P24 D 16.0 LI501-H4 2<br />
2 2.3 4.0 55 240 7C550P24 D 13.5 LI501-H4 2<br />
2 2.3 4.0 55 240 7C550P24 D 13.5 LI501-H4 2<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
D<br />
D/C<br />
D<br />
D<br />
D<br />
D/D/<br />
D/D<br />
D/D/<br />
D/D<br />
C/C/<br />
D/D/<br />
C<br />
D/<br />
D/D<br />
D/<br />
D/D<br />
120/<br />
208/240 71A84E6 CWI 465 4.2/<br />
2.4/2.1<br />
190<br />
10/<br />
7/5<br />
V<br />
2 2.7 4.4 48 300 7C480P30 D 15.5 LI501-J4 2<br />
E/<br />
E/E<br />
120/240 71A8456 CWI 465 4.2/2.1 190 10/5 M 2 2.7 4.4 48 300 7C480P30 D 15.5 LI501-J4 2<br />
480/120T<br />
120/240<br />
120/277<br />
240/480<br />
71A8440-T<br />
71A8450<br />
71A8480<br />
71A8460<br />
Regulated<br />
Lag<br />
490<br />
1.1<br />
4.2/2.1<br />
4.2/1.8<br />
2.1/1.1<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />
Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-500 includes core & coil with oil-filled capacitor<br />
-510 includes core & coil with welded bracket and oil-filled capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For CWA, CWI and Regulated Lag circuits, figure is operating current.<br />
✝✝ Each ballast requiring an ignitor is furnished as standard with the Short<br />
Range ignitor model shown for use within fixtures. If a Long Range ignitor<br />
is required for remote mounting, specify on order. See pages 5-50 to 5-53<br />
for additional information.<br />
NOM Certified ballast available for Mexican and Central American markets.<br />
215<br />
5<br />
10/5<br />
10/5<br />
5/5<br />
N<br />
3 3.6 5.3 24 480 MD2409-000 O 26.0 LI501-H4 2<br />
E/E<br />
C<br />
D/C<br />
D/C<br />
D/B<br />
HID • CORE & COIL<br />
HPS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-43
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />
High Pressure Sodium<br />
N<br />
N<br />
N<br />
N<br />
N<br />
N<br />
Input<br />
Volts<br />
430 Watt Lamp, ANSI Code S145 (SON AGRO-Philips)<br />
120/<br />
208/240<br />
277/<br />
347/480<br />
600 Watt Lamp, ANSI Code S106<br />
120/<br />
208/240<br />
277/<br />
347/480<br />
120/<br />
208/240<br />
277/<br />
347/480<br />
71A85E5 CWA 670<br />
71A85F5<br />
5.5/<br />
3.3/2.9<br />
220<br />
2.5/<br />
CWA 665 230<br />
2.0/1.4<br />
750 Watt Lamp, ANSI Code S111<br />
120/<br />
208/240<br />
277/<br />
347/480<br />
Catalog✝<br />
Number<br />
71A85E6<br />
71A85F6<br />
71A85E8<br />
71A85F8<br />
Circuit<br />
Type<br />
CWI<br />
CWI<br />
CWI<br />
CWI<br />
Watts<br />
Input<br />
490<br />
490<br />
685<br />
685<br />
71A86E5 CWA 840<br />
71A86F5 CWA 840<br />
Max•<br />
Input<br />
Current<br />
5.2/<br />
3.0/2.6<br />
2.3/<br />
1.8/1.3<br />
6.2/<br />
3.5/3.1<br />
2.6/<br />
2.1/1.5<br />
6.8/<br />
4.0/3.5<br />
3.1/<br />
2.5/1.8<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
200<br />
200<br />
240<br />
238<br />
220<br />
225<br />
Fuse<br />
Rating<br />
(Amps)<br />
15/<br />
10/7<br />
7/<br />
5/5<br />
15/<br />
9/8<br />
7/<br />
5/4<br />
20/<br />
9/8<br />
7/<br />
6/5<br />
20/<br />
10/10<br />
10/<br />
10/5<br />
Wiring<br />
Dia<br />
Y<br />
V<br />
M<br />
M<br />
V<br />
V<br />
M<br />
M<br />
Dimensions<br />
Fig<br />
2<br />
2<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
15.0<br />
8a 3.2 5.1 64 280 7C640S28-R D 22.5 LI561-H5 2<br />
8a 3.2 5.1 64 280 7C640S28-R D 23.0 LI561-H5 5<br />
8a<br />
8a<br />
A<br />
2.6<br />
2.6<br />
3.4<br />
3.4<br />
B<br />
4.1<br />
4.1<br />
5.3<br />
5.3<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
48 300 7C480P30<br />
48 300 7C480P30 D 15.0<br />
48 330 7C480S33-R<br />
8a 3.2 5.1 75 280 7C750S28-R D 22.5 LI561-H5 5<br />
8a 3.2 5.1 75 280 7C750S28-R D 23.0<br />
D<br />
D<br />
Total<br />
Weight<br />
(Ibs)<br />
26.0<br />
48 330 7C480S33-R D 26.0<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
LI501-H4<br />
LI501-H4<br />
LI561-H5<br />
LI561-H5<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
15<br />
15<br />
2<br />
2<br />
LI561-H5 5<br />
U.L. Bench Top<br />
Rise Code 1029<br />
(Pg 5-3)<br />
ADVANCE<br />
Class H<br />
Class N<br />
(180°C)<br />
(200°C)<br />
C/<br />
E/D<br />
F/<br />
C/B<br />
A/<br />
A/B<br />
A/<br />
A/A<br />
D/<br />
D/C<br />
D/<br />
D/C<br />
D/<br />
E/E<br />
E/<br />
D/D<br />
—<br />
—<br />
A/<br />
A/A<br />
A/<br />
A/A<br />
A/<br />
A/A<br />
A/<br />
A/A<br />
A/<br />
A/A<br />
A/<br />
A/A<br />
HID • CORE & COIL<br />
HPS<br />
✝ Ordering information:<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For CWA and CWI circuits, figure is operating current.<br />
✝✝ Each ballast requiring an ignitor is furnished as standard with the Short Range ignitor<br />
model shown for use within fixtures. If a Long Range ignitor is required for remote<br />
mounting, specify on order. See pages 5-50 to 5-53 for additional information.<br />
N Dual rated Class H (180°C) / ADVANCE Class N (200°C) insulation system.<br />
Refer to page 5-3 for additional information.<br />
B<br />
MAX.<br />
3 7 /8"<br />
4 1 /4"<br />
A<br />
4 3 /8"<br />
5 3 /8" 6 "<br />
8 Holes cleared for<br />
#10 thru-bolts<br />
Fig. 88a<br />
(4 1 /4" x 6" core)<br />
B<br />
MAX.<br />
A<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
LINE V<br />
LAMP<br />
H4<br />
H4<br />
H4<br />
LAMP 1<br />
4 1 /4"<br />
LINE V<br />
208 V<br />
208 V<br />
208 V<br />
LINE V<br />
LINE V<br />
CAP<br />
CAP<br />
CAP<br />
X3 X1<br />
IGNITOR<br />
X2<br />
LAMP<br />
120 V<br />
H2<br />
H3<br />
H1<br />
208V H2<br />
H3<br />
H1<br />
240 V H2<br />
H3<br />
H1<br />
CAP<br />
X3 X1<br />
IGNITOR<br />
X2<br />
CAP<br />
LAMP 2<br />
LAMP<br />
3 7 /8"<br />
4 3 /8" 4 3 /4"<br />
Fig. 2<br />
(4 1 /4" x 4 3 /4" core)<br />
COM<br />
Fig. M<br />
COM<br />
Fig. Y<br />
LINE V<br />
LAMP 1<br />
LINE V<br />
LINE V<br />
COM<br />
CAP<br />
X3 X1<br />
IGNITOR<br />
X2<br />
CAP<br />
LAMP 2<br />
LAMP<br />
WELDED BallastBRACKET L DIMENSIONS W M<br />
Dimensions Fig<br />
S<br />
2 6.5 1.25 5.75 0.28<br />
8a 7.8 4.50 6.75 0.31<br />
Fig. V<br />
5-44<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />
HID<br />
High Pressure Sodium<br />
NOM<br />
N<br />
N<br />
N<br />
N<br />
N<br />
N<br />
N<br />
Input<br />
Volts<br />
1000 Watt Lamp, ANSI Code S52<br />
120<br />
220<br />
277<br />
480<br />
120/208/<br />
240/277<br />
120/208/<br />
240/277<br />
120/208/<br />
240/277/<br />
480<br />
Catalog✝<br />
Number<br />
71A8703<br />
71A87J3<br />
71A8733<br />
71A8743<br />
71A8743-001<br />
71A8793 CWA 1100<br />
9.5/5.5/<br />
4.8/4.2<br />
71A8773-001 CWA 1100<br />
9.5/5.5/<br />
4.8/4.2<br />
71A8753<br />
71A8753-001<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
CWA 1100<br />
120/<br />
277/347 71A87A3 CWA 1100 9.5/<br />
4.2/3.3<br />
120/<br />
277/347 71A87A3-001 CWA 1100 9.5/<br />
4.2/3.3<br />
435<br />
435<br />
435<br />
25/15/<br />
10/10<br />
25/15/<br />
10/10<br />
25/15/<br />
12/10/<br />
6<br />
25/<br />
15/10<br />
Cap Catalog<br />
Number<br />
CWA 1100 2.3 435 6 M 8a 3.9 5.8 26 525 MD2602-030 O 28.0 LI571-H5 ★ 15 C<br />
CWA 1100<br />
Max•<br />
Input<br />
Current<br />
9.2<br />
5.0<br />
4.0<br />
9.3/5.3/<br />
4.7/4.1/<br />
2.3<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
435<br />
437<br />
435<br />
Fuse<br />
Rating<br />
(Amps)<br />
25<br />
15<br />
10<br />
25/<br />
15/10<br />
Wiring<br />
Dia<br />
M<br />
M<br />
M<br />
M<br />
Dry<br />
or<br />
Oil<br />
M 8a 3.8 5.8 26 525 MD2602-030 O 28.0 LI571-H5 ★ 15<br />
M<br />
Dimensions<br />
Fig<br />
A<br />
B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Total<br />
Weight<br />
(Ibs)<br />
8a 3.8 5.8 26 525 MD2602-030 O 28.0<br />
8a 3.8 5.8 26 525 MD2602-030 O 28.0<br />
8a 4.0 6.0 26 525 MD2602-030 O 29.0<br />
8a 3.9 5.9 26 525 MD2602-030 O 28.0<br />
8a 3.9 5.9 26 525 MD2602-030 O 28.0<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
LI571-H5 ★ 15<br />
LI571-H5 ★ 15<br />
LI571-H5 ★ 15<br />
LI571-H5 ★ 15<br />
LI571-H5 ★ 15<br />
U.L. Bench Top<br />
Rise Code 1029<br />
(Pg 5-3)<br />
ADVANCE<br />
Class H<br />
Class N<br />
(180°C)<br />
(200°C)<br />
B<br />
C<br />
C<br />
C/B/<br />
C/C<br />
C/B/<br />
C/C<br />
C/C/<br />
C/C/<br />
C<br />
C/<br />
C/C<br />
C/<br />
C/C<br />
A<br />
A<br />
A<br />
A<br />
A/A/<br />
A/A<br />
A/A/<br />
A/A<br />
A/A/<br />
A/A/<br />
A<br />
A/<br />
A/A<br />
A/<br />
A/A<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001.<br />
Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500 includes core & coil with oil-filled capacitor<br />
-510 includes core & coil with welded bracket and oil-filled capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For CWA circuits, figure is operating current.<br />
✝✝ Each ballast requiring an ignitor is furnished as standard with the Short<br />
Range ignitor model shown for use within fixtures. If a Long Range ignitor<br />
is required for remote mounting, specify on order. See pages 5-50 to 5-53<br />
for additional information.<br />
★ Equipped with an auto-reset thermal protector to prevent ignitor from overheating<br />
in the event of lamp failure.<br />
Canadian replacement/retrofit ballast kit indicated by bold type.<br />
Refer to page 5-10.<br />
N Dual rated Class H (180°C) / ADVANCE Class N (200°C) insulation system.<br />
Refer to page 5-3 for additional information.<br />
NOM Certified ballast available for Mexican and Central American markets.<br />
HID • CORE & COIL<br />
HPS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-45
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
Low Pressure Sodium<br />
Input<br />
Volts<br />
Catalog ✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Dimensions<br />
Fig A B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
U.L.<br />
Bench<br />
Top Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
18 Watt Lamp, ANSI Code L69<br />
120/277 71A0280<br />
HX-NPF<br />
HX-PFC<br />
30<br />
.9/.4<br />
1.0/.5<br />
315<br />
3/2<br />
3/2<br />
Q<br />
1 1.0 2.4<br />
—<br />
5<br />
—<br />
250<br />
—––––––<br />
7C050L33<br />
D<br />
4.0<br />
4.5<br />
A/A<br />
35 Watt Lamp, ANSI Code L70<br />
or 55 Watt Lamp, ANSI Code L71<br />
New<br />
120/208/<br />
240/277<br />
71A0490<br />
71A0490-001D<br />
HX-HPF/<br />
HX-PFC<br />
60 or 80<br />
2.35/1.39/<br />
1.18/0.98<br />
480<br />
6/4/<br />
3/3<br />
Q<br />
1<br />
2.3 3.5 14 240 7C140M33-R D 8.0<br />
A/A/<br />
A/A<br />
New<br />
347/480 71A04F0 HX-HPF 60 or 80 0.79/0.58 480 2/2 Q2 1 2.3 3.5 14 240 7C140M33-R D 8.0 A/A<br />
= Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />
Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For HX circuits, figure is highest of starting, operating or open circuit current.<br />
B<br />
MAX.<br />
A<br />
2 13 /16"<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
2 7 /16"<br />
3 1 /2" 3 15 /16"<br />
Fig. 1<br />
(3" x 4" core)<br />
B<br />
MAX.<br />
A<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
4 1 /4"<br />
HID • CORE & COIL<br />
LPS<br />
LINE V<br />
CAP<br />
LAMP<br />
LAMP<br />
3 7 /8"<br />
4 3 /8" 4 3 /4"<br />
Fig. 2<br />
(4 1 /4" x 4 3 /4" core)<br />
COM<br />
COM<br />
Fig. B<br />
LINE V<br />
LAMP<br />
CAP<br />
LAMP<br />
LINE V<br />
LINE V<br />
CAP<br />
LAMP<br />
COM<br />
CAP<br />
LINE V<br />
LAMP<br />
WELDED BRACKET DIMENSIONS<br />
Fig. C<br />
COM<br />
Fig. Q<br />
COM<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
1 5.1 1.00 4.50 0.25<br />
2 6.5 1.25 5.75 0.28<br />
3 7.8 2.75 6.13 0.25<br />
5-46<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
HID<br />
Low Pressure Sodium<br />
Input<br />
Volts<br />
Catalog ✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Dimensions<br />
Fig A B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
U.L.<br />
Bench<br />
Top Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
90 Watt Lamp, ANSI Code L72<br />
New<br />
120/208/<br />
240/277<br />
71A0590<br />
71A0590-001D<br />
HX-HPF 125<br />
4.1/2.3/<br />
2.0/1.75<br />
515<br />
11/6/<br />
5/5<br />
Q4<br />
2 1.8 3.3 17.5 330 7C175M33-R<br />
D<br />
10.0<br />
A/A/<br />
A/A<br />
New<br />
347/480 71A05F0 HX-HPF 125 1.35/0.95 520 4/3 Q2 2 1.8 3.4 16.0 330 7C160M33 D 10.2 A/A<br />
New<br />
New<br />
135 Watt Lamp, ANSI Code L73<br />
180 Watt Lamp, ANSI Code L74<br />
120/208/<br />
240/277<br />
71A0790<br />
71A0790-001D<br />
HX-HPF<br />
347/480 71A07F0 HX-HPF<br />
180 or<br />
208<br />
182 or<br />
213<br />
5.28/2.82/<br />
2.65/2.25<br />
695<br />
15/7/<br />
7/6<br />
Q<br />
3 2.4 4.0 16 330 7C160M33<br />
1.82/1.33 690 5/4 Q2 3 2.4 4.0 16 330 7C160M33 D 15.0 A/A<br />
D<br />
15.3<br />
A/A/<br />
A/A<br />
✝ Ordering information:<br />
Replacement/retrofit ballast kits indicated by bold type with suffix -001D.<br />
Refer to pages 5-5 to 5-9.<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
-610 core & coil with welded bracket (no capacitor)<br />
• For HX circuits, figure is highest of starting, operating or open circuit current.<br />
HID • CORE & COIL<br />
LPS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-47
HID - NON-PCB CAPACITORS<br />
HID • CAPACITORS<br />
CAPACITOR SPECIFICATIONS<br />
Height<br />
New<br />
Max<br />
Case<br />
Temp<br />
105°C<br />
Diameter<br />
Dry-Film<br />
Capacitors<br />
Thermal<br />
Plastic Case<br />
Dry-film capacitors<br />
contain no oil; are<br />
furnished with 8”<br />
leads and include<br />
integral resistor<br />
where required.<br />
CC-175<br />
Mounting Clip<br />
For 1.25 thru 1.75 in. diameter Round<br />
Case (Furnished as standard with -001<br />
and -001 D suffix ballasts).<br />
Max Case<br />
Temp 90°C<br />
3/16” Dia.<br />
Recommended Capacitors for Bi-level Ballast Operation<br />
<strong>Advance</strong><br />
Ballast Family<br />
Nominal<br />
Lamp Watts<br />
ANSI<br />
Code<br />
2 1/8”<br />
Lamp Watts<br />
at Low Light<br />
Metal Halide 60 Hz CWA/SuperCWA <strong>Ballasts</strong><br />
71A54_3 150<br />
M102/14<br />
2<br />
CC-200<br />
Mounting Clip<br />
For 2.00 in. diameter Round<br />
Case. Mount in the middle of can.<br />
Full Light<br />
Capacitance Mfd.<br />
Oil-Filled Capacitor<br />
Furnished with appropriate leads<br />
and/or resistors where required.<br />
Case must be grounded.<br />
Note: Capacitor boots available,<br />
order catalog number CB-100.<br />
Low Light<br />
Capacitance Mfd.<br />
90 22.0 15.0<br />
71A55_0 175 M57 122 10.0 8.0<br />
71A55_3<br />
71A56_2 or<br />
71A56_3<br />
71A57_0 or<br />
71A57_1<br />
71A57_2<br />
71A58_2<br />
71A59_3<br />
175<br />
Pulse-Start<br />
200<br />
Pulse-Start<br />
M137 or<br />
M152<br />
102 11.0 7.7<br />
M136 102 15.0 9.3<br />
250 M58 127 15.0 9.0<br />
250<br />
Pulse-Start<br />
320<br />
Pulse-Start<br />
350<br />
Pulse-Start<br />
M138 or<br />
M153<br />
M132 or<br />
M154<br />
133 17.0 10.8<br />
149 21.0 13.1<br />
M131 163 22.5 14.4<br />
71A60_1 400 M59 192 24.0 15.0<br />
71A60_2<br />
71A63_2<br />
71A64_2<br />
71A65_0, 71A65_1,<br />
71A65_2, or 71A65_3<br />
400<br />
Pulse-Start<br />
450<br />
Pulse-Start<br />
750<br />
Pulse-Start<br />
1000 Probe or<br />
Pulse-Start<br />
M135 or<br />
M155<br />
210 26.0 18.5<br />
M144 212 26.5 16.7<br />
M149 380 28.0 18.0<br />
M47 or<br />
M141<br />
Max<br />
Case<br />
Temp<br />
105°C<br />
571 24.0 15.0<br />
71A80_8 100 S54 52 34.0 26.0<br />
71A81_8 150 S55 66 55.0 40.0<br />
Dry-Film Capacitors<br />
Dimensions (in)<br />
Letter Diameter Height<br />
L 1.25 2.9<br />
M 1.50 2.9 or 3.75<br />
P 1.75 3.75 or 5.15<br />
S 2.00 5.15<br />
Primary<br />
Capacitor<br />
22.0 mfd, 240V<br />
(7C220M24-R)<br />
10 mfd, 400V<br />
(7C100M40-R)<br />
11 mfd, 400V<br />
(7C110M40)<br />
15 mfd, 330V<br />
(7C150M33)<br />
15 mfd, 400V<br />
(7C150P40-R)<br />
17 mfd, 330V<br />
(7C170M33)<br />
21 mfd, 345V<br />
(7C210P34-R)<br />
22.5 mfd, 345V<br />
(7C225P34)<br />
24 mfd, 400V<br />
(7C240P40-R)<br />
18.5 mfd, 330V<br />
(7C185P33-R)<br />
26.5 mfd, 400V<br />
(7C265P40-R)<br />
18 mfd, 400V<br />
(7C180P40-R)<br />
24 mfd, 480V<br />
(MD2409-100)<br />
26.0 mfd, 330V<br />
(7C260P33-R)<br />
40 mfd, 300V<br />
(7C400P30-R)<br />
28 mfd, 300V<br />
(7C280P30-R)<br />
40 mfd, 300V<br />
(7C400P30-R)<br />
35 mfd, 300V (7C350P30-R)<br />
in parallel with 20 mfd, 300V<br />
(7C200P33-R)<br />
26 mfd, 525V<br />
(MD2602-030)<br />
Secondary<br />
Capacitor<br />
48.0 mfd, 300V<br />
(7C480P30)<br />
40 mfd, 300V<br />
(7C400P30-R)<br />
26 mfd, 330V<br />
(7C260:33-R)<br />
24 mfd, 300V<br />
(7C240P30)<br />
22.5 mfd, 300V<br />
(7C225P30-R)<br />
30 mfd, 345V<br />
(7C300S34)<br />
35 mfd, 300V<br />
(7C350P30-R)<br />
40 mfd, 300V<br />
(7C400 P30-R)<br />
40 mfd, 300V<br />
(7C400P30-R)<br />
7.5 mfd, 330V<br />
(7C075L33)<br />
45.0 mfd, 120V<br />
(7C450P12)<br />
10 mfd, 400V<br />
(7C100M40-R)<br />
40 mfd, 300V<br />
(7C400P30-R)<br />
8.0 mfd, 330V<br />
(7C080L33-R)<br />
15 mfd, 330V<br />
(7C150M33)<br />
7 mfd, 330V<br />
(7C070L33-R)<br />
15 mfd, 330V<br />
(7C150M33)<br />
Capacitor<br />
Connection<br />
71A53_3 100 M90/140 55 10.0 7.8 10.0 mfd 330V 35.0 mfd 300V Series<br />
71A64_8 875 - 440 21.0 13.1 21 mfd 480V 35 mfd 170V Series<br />
71A64_8 875 - 440 21.0 13.1 13 mfd 480V 8 mfd 480V Parallel<br />
High Pressure Sodium 60 Hz CWA <strong>Ballasts</strong><br />
New<br />
71A82_1 250 S50 144 35.0 28.0<br />
71A84_3 400 S51 189 55.0 40.0<br />
71A86_5 750 S111 356 75.0 55.0<br />
71A87_3 1000 S52 406 26.0 17.7<br />
Oil-Filled Capacitors<br />
Dimensions (in)<br />
Oval A B Height<br />
1.25 1.30 2.15<br />
1.25 1.55 2.70 As Shown<br />
1.75 1.90 2.90 in Tables<br />
2.00 1.95 3.65<br />
20 mfd, 330V<br />
(7C200P33-R)<br />
55 mfd, 240V<br />
(7C550P24)<br />
71A89_1 200 S66 130 24.0 18.0 24 mfd 280V 72 mfd 120V Series<br />
Series<br />
Series<br />
Series<br />
Series<br />
Series<br />
Series<br />
Series<br />
Series<br />
Series<br />
Parallel<br />
Series<br />
Parallel<br />
Series<br />
Parallel<br />
Parallel<br />
Parallel<br />
Parallel<br />
Parallel<br />
Series<br />
71A89_1 200 S66 130 24.0 18.0 18 mfd 280V 6 mfd 280V Parallel<br />
5-48<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HID - NON-PCB CAPACITORS<br />
Capacitor Specifications<br />
Mfd.<br />
5.0<br />
6.0<br />
7.0<br />
7.5<br />
8.0<br />
8.4<br />
10.0<br />
10.0<br />
11.0<br />
12.0<br />
12.0<br />
13.0<br />
13.0<br />
14.0<br />
14.0<br />
15.0<br />
15.0<br />
16.0<br />
16.0<br />
16.0<br />
16.0<br />
17.0<br />
17.0<br />
17.0<br />
17.5<br />
18.0<br />
18.5<br />
20.0<br />
20.0<br />
20.0<br />
21.0<br />
21.0<br />
22.0<br />
22.5<br />
22.5<br />
22.5<br />
24.0<br />
24.0<br />
24.0<br />
24.0<br />
24.0<br />
25.5<br />
26.0<br />
26.0<br />
26.0<br />
26.0<br />
26.5<br />
28.0<br />
28.0<br />
28.0<br />
28.0<br />
30.0<br />
32.0<br />
34.0<br />
34.0<br />
35.0<br />
35.0<br />
36.0<br />
40.0<br />
40.0<br />
45.0<br />
45.0<br />
48.0<br />
48.0<br />
48.0<br />
52.0<br />
52.0<br />
52.0<br />
55.0<br />
55.0<br />
55.0<br />
58.0<br />
60.0<br />
64.0<br />
66.0<br />
75.0<br />
Voltage<br />
330<br />
330<br />
330<br />
330<br />
330<br />
330<br />
330<br />
400<br />
400<br />
330<br />
450<br />
330<br />
525<br />
120<br />
330<br />
330<br />
400<br />
300<br />
400<br />
525<br />
525<br />
400<br />
550<br />
550<br />
300<br />
400<br />
330<br />
120<br />
330<br />
450<br />
345<br />
525<br />
240<br />
300<br />
345<br />
345<br />
300<br />
400<br />
400<br />
480<br />
480<br />
400<br />
330<br />
330<br />
540<br />
540<br />
400<br />
120<br />
300<br />
400<br />
580<br />
345<br />
525<br />
240<br />
550<br />
240<br />
300<br />
120<br />
120<br />
300<br />
120<br />
300<br />
300<br />
300<br />
330<br />
120<br />
240<br />
280<br />
120<br />
240<br />
240<br />
240<br />
240<br />
280<br />
280<br />
280<br />
7C Dry Capacitor<br />
Part Number<br />
7C050L33<br />
7C060L33<br />
7C070L33R<br />
7C075L33<br />
7C080L33R<br />
7C084L33R<br />
7C100M33R<br />
7C100M40R<br />
7C110P40<br />
7C120M33R<br />
MD1204-100<br />
7C130M33<br />
MD1300-100<br />
7C140L12<br />
7C140M33R<br />
7C150M33<br />
7C150P40R<br />
7C160M30<br />
7C160P40<br />
MD1606-000<br />
MD1606-100<br />
7C170P40<br />
MD1701-000<br />
MD1701-100<br />
7C175M30R<br />
7C180P40R<br />
7C185P33R<br />
7C200M12<br />
7C200P33R<br />
MD2006-100<br />
7C210P34R<br />
MD2100-030<br />
7C220M24R<br />
7C225P30R<br />
7C225P34<br />
7C225S34<br />
7C240P30<br />
7C240P40R<br />
7C240S40R<br />
MD2409-000<br />
MD2409-100<br />
7C255P40R<br />
7C260P33R<br />
7C260S33R<br />
MD2602-030<br />
MD2602-100<br />
7C265P40R<br />
7C280M12<br />
7C280P30R<br />
7C280S40<br />
MD1408-230<br />
7C300S34<br />
MD3202-100<br />
7C340P24<br />
MD1701-200<br />
7C350P24<br />
7C350P30R<br />
7C360M12<br />
7C400P30R<br />
7C450P12<br />
7C450P30R<br />
7C480P30<br />
7C480P30R<br />
7C480S33R<br />
7C520P12<br />
7C520P24<br />
7C520S28R<br />
7C550P12<br />
7C550P24<br />
7C550P24R<br />
7C580P24<br />
7C600P24<br />
7C640S28R<br />
7C660S28<br />
7C750S28R<br />
7T Dry Capacitor<br />
Part Number<br />
7T160P40R<br />
7T180P40R<br />
7T200P33R<br />
7T225P30R<br />
7T240P30R<br />
7T240S40R<br />
7T280P12R<br />
7T280P30R<br />
7T300S34R<br />
7T340P24R<br />
7T350P24R<br />
7T360P12R<br />
7T400P12R<br />
7T400S30R<br />
7T450S30R<br />
7T550P12R<br />
Dia/Oval<br />
7C/7T<br />
1.25<br />
1.25<br />
1.25<br />
1.25<br />
1.25<br />
1.50<br />
1.50<br />
1.50<br />
1.75<br />
1.75<br />
1.75<br />
1.25<br />
1.75<br />
1.50<br />
1.50<br />
1.75<br />
1.50<br />
1.75<br />
1.75<br />
1.75<br />
1.75<br />
1.75<br />
1.75<br />
1.75<br />
1.50<br />
1.75<br />
1.75<br />
1.75<br />
1.50<br />
1.75<br />
1.75<br />
1.75<br />
1.50<br />
1.75<br />
1.75<br />
2.00<br />
1.75<br />
1.75<br />
2.00<br />
1.75<br />
1.75<br />
1.75<br />
1.75<br />
2.00<br />
1.75<br />
1.75<br />
1.75<br />
1.5/1.75<br />
1.75<br />
2.00<br />
1.50<br />
2.00<br />
2.00<br />
1.75<br />
1.75<br />
1.75<br />
1.75<br />
1.50<br />
2.00<br />
1.75/2.00<br />
1.75<br />
1.75/2.00<br />
1.75<br />
1.75<br />
2.00<br />
1.75<br />
1.75<br />
1.75<br />
1.75<br />
1.75<br />
1.75<br />
2.00<br />
1.75<br />
2.00<br />
2.00<br />
2.00<br />
Height<br />
7C/7T<br />
2.90<br />
2.90<br />
2.90<br />
2.90<br />
2.90<br />
2.90<br />
3.75<br />
3.75<br />
3.75<br />
3.75<br />
2.90<br />
3.75<br />
3.90<br />
2.90<br />
3.75<br />
3.75<br />
3.75<br />
3.75<br />
3.75/4.70<br />
3.90<br />
3.90<br />
3.75<br />
3.90<br />
3.90<br />
3.75<br />
3.75/4.70<br />
3.90<br />
3.90<br />
3.75/4.70<br />
3.90<br />
5.12<br />
4.80<br />
2.90<br />
3.75/4.70<br />
5.12<br />
3.75<br />
3.75/4.70<br />
5.12<br />
3.75/4.70<br />
3.90<br />
3.90<br />
3.75<br />
5.12<br />
3.75<br />
5.30<br />
5.30<br />
5.12<br />
2.90/4.70<br />
3.75/4.70<br />
5.12<br />
3.90<br />
5.12/4.70<br />
3.90<br />
3.75/4.70<br />
3.90<br />
3.75/4.70<br />
5.12<br />
3.75/4.70<br />
4.70<br />
5.12/4.70<br />
3.75<br />
5.12/4.70<br />
5.12<br />
5.12<br />
5.12<br />
3.75<br />
5.12<br />
3.90<br />
5.12/4.70<br />
3.75<br />
5.12<br />
5.12<br />
5.12<br />
5.12<br />
5.12<br />
5.12<br />
Ballast family where used<br />
71A02x0, 5037, 5081, 5137, 78x1 (60 Hz)<br />
71A5181, 78R1<br />
71A1580, 50x7 (50 Hz. only), 79x1 (60 Hz)<br />
Bi-Level<br />
71A20x0, 52x0, 52x2 (60 Hz. only), 5237, 5281<br />
71A79x1 (50 Hz)<br />
71A25x1 (60 Hz), 50Y1, 52Y1, 52Y2, 5337, 5340-T, 5383, 53Y3, 80x1 (60 Hz)<br />
71A55x0 (60 Hz)<br />
71A55x3<br />
71A25x1 (50 Hz), 29D1, 50x1 (50 Hz), 53x0 (60Hz, except 5340-T), 5637, 80x1 (50 Hz)<br />
71A55x0 (50 Hz)<br />
Bi-Level<br />
71A57E6<br />
71A7707<br />
71A04x0, 29R0, 52x1 (50 Hz), 52x2 (50 Hz), 5437, 5737, 81x2 (60 Hz)<br />
71A56x2, 56x3<br />
71A57x0 (60 Hz), 57x1<br />
71A05F0, 54x0, 54x2, 80x0<br />
71A81x0, 07x0<br />
71A57x4, 82x0<br />
71A43x0<br />
71A55x4, 57x2, 5634, 56x3 (50 Hz)<br />
71A83x0<br />
71A69x0 (Use one 17 mfd-550V and one 26 mfd-540V in parallel)<br />
71A0590, 30x2, 53N0, 5837, 81x2 (50 Hz)<br />
71A57x0 (50 Hz), 89x4<br />
Bi-Level<br />
71A0201, 7705, 7807<br />
71A57x2 (50 Hz), 53MO, 5880, 5937, 6037, 6137, 79xO, 81R6, 8146, 8176, 8196<br />
71A60x6<br />
71A58x2 (60 Hz)<br />
71A59x4, 60x4 (60 Hz), 6334, 64x8<br />
71A54A3<br />
71A35x2 (60 Hz), 5486, 6337<br />
71A59x3<br />
Alternative to 7C225P34<br />
71A79x6, 89x1<br />
71A58x2 (50 Hz), 60x1 (60 Hz), 63x2<br />
Alternative to 7C240P40R<br />
71A84x0, 65x3 (60 Hz), 65x1<br />
71A50x0, 60N1, 65x2 (60 Hz), 65x0<br />
71A59x3 (50 Hz)<br />
71A60x2 (60 Hz), 61E6<br />
Alternative to 7C260P33R<br />
71A69x0 (Uses one 17 mfd-540V and one 26 mfd-540V capacitor in parallel), 87x3 (60 Hz)<br />
71A60M2, 65x2 (50 Hz), 65x3 (50 Hz only)<br />
71A63x3 (60 Hz)<br />
71A5005, 5105, 7805, 7907<br />
71A35R2, 54x2 (50 Hz), 79x8, 82x6, 89x0<br />
71A64x0, 64x2 (60 Hz)<br />
71A87x3 (50 Hz only, uses two 14mfd-580 volt capacitors in parallel)<br />
71A60N2<br />
71A67x2 (60 Hz)<br />
71A80x8<br />
71A68x0 (Uses two 17mfd-550 volt capacitors in parallel)<br />
71A54M2, 80x6, 82x1 (60 Hz)<br />
71A40x1 (60 Hz)<br />
71A5205, 8007, 50Y5<br />
71A40R1, 65E6 (two in series), 82x1 (50 Hz only), 65Y6 (two in series)<br />
71A8005<br />
71A65M6, 83x1<br />
71A84x6, 85x6<br />
71A84x6, 85x6<br />
71A85x8<br />
71A8156, 81E6<br />
Bi-Level<br />
71A8107<br />
71A81x8, 84x3 (60 Hz)<br />
Alternative to 7C550P24<br />
71A8593<br />
71A84x3 (50 Hz), 85x5<br />
71A86x5<br />
HID • CAPACITORS<br />
1. All capacitors contain no PCB’s. 2. Capacitors include a discharge resistor where required by UL. 3. MD_ Denotes 90° Oil Filled, 7C_ Denotes 105° Dry Film.<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 5-49
HID - CORE & COIL BALLASTS<br />
IGNITORS<br />
<strong>Ballasts</strong> that include an ignitor to start the HID lamp are<br />
limited in the distance which they may be mounted remotely<br />
from the lamp because the ignitor pulse attenuates as the wire<br />
length between the ballast and lamp increases. All <strong>Advance</strong><br />
Transformer Co. open core & coil ballasts listed in this <strong>Atlas</strong><br />
include a standard ignitor that provides the proper electrical<br />
pulse to start lamps when the ballast is mounted within the<br />
lighting fixture. For most of these ballast/ignitor combinations,<br />
the maximum ballast-to-lamp distance is listed as 2 feet.<br />
For ballast-to-lamp distances greater than the capability of the<br />
standard ignitor, a long range ignitor is required.<br />
Use the tables on the following pages to find the proper<br />
long range ignitor for various metal halide and high pressure<br />
sodium ballasts. Not all ballasts listed in the <strong>Atlas</strong> have long<br />
range ignitor options. It may be necessary to use a ballast<br />
employing a different circuit to achieve the needed ballast-tolamp<br />
distance.<br />
Whichever ignitor is used, it must be installed with and<br />
adjacent to the core & coil, as the two components work<br />
together to deliver the proper pulse to the lamp. Do not install<br />
ignitors next to a remote lamp because the electrical pulse will<br />
be further attenuated as it first has to travel from the ignitor to<br />
the core & coil and then back to the lamp, thus doubling the<br />
actual ballast-to-lamp distance.<br />
When ordering ballasts with long range ignitors, indicate<br />
such on the purchase order, e.g.:<br />
71A8493-500D except with LI501-J4 L.R. Ignitor<br />
BALLAST-TO-LAMP REMOTE MOUNTING DISTANCES<br />
MERCURY VAPOR AND METAL HALIDE BALLASTS<br />
The distances at which most Mercury Vapor and Metal<br />
Halide ballasts can be located from their respective lamps are<br />
limited by the ballast-to-lamp wire size. The exceptions being<br />
the ballasts for the new, Metal Halide lamps which require an<br />
ignitor for starting. The mounting distances for these are limited<br />
by the ignitor as shown on the following page.<br />
Use this chart to determine the minimum wire size<br />
required for the Mercury and Metal Halide (not requiring an<br />
ignitor) lamps shown:<br />
LAMP<br />
MAXIMUM ONE-WAY<br />
LENGTH OF WIRE BETWEEN<br />
LAMP AND BALLAST (FEET)<br />
(Voltage Drop Limited to<br />
1% of Lamp Voltage)<br />
Wattage Mercury<br />
Metal<br />
Halide<br />
#10 #12 #14 #16 #18<br />
100 H38 — 750 470 295 185 115<br />
175 H39 M57 425 265 165 105 65<br />
250 H37 M58 300 190 120 75 45<br />
1-400 or<br />
2-400<br />
H33 M59 200 125 75 50 30<br />
700 H35 — 465 290 180 115 70<br />
1000 H36 M47 325 205 125 80 50<br />
1500 — M48 225 140 85 55 35<br />
HID • IGNITORS<br />
ADVANCE INSTANT RESTRIKE IGNITOR<br />
The <strong>Advance</strong> Instant Restrike Ignitor enhances the performance<br />
of high pressure sodium ballasts for applications in which<br />
quick restart is essential. If the lamp extinguished due to a system<br />
voltage dip, the ignitor is enabled and pulses to restrike the lamp.<br />
Should the lamp extinguish due to high lamp voltage (characteristic<br />
at end of lamp life), the ignitor prevents lamp cycling by remaining<br />
disabled and not restriking the lamp. When the lamp is inoperative,<br />
the Instant Restrike Ignitor automatically shuts off to avoid continuos,<br />
high energy pulsing. The Instant Restrike Ignitor is for use with:<br />
• <strong>Advance</strong> high reactance or reactor ballasts only. Mains voltage<br />
must be 120v, or ballast must have a 120v tap available, for<br />
powering the LI555-IR ignitor.<br />
• Mogul-based high pressure sodium lamps rated 150 watts<br />
(55-volt lamps only).<br />
• 5kv pulse-rated mogul-based lamp sockets.<br />
• Maximum recommended ballast to lamp distance is 2 ft.<br />
For complete details of the <strong>Advance</strong> Instant Restrike Ignitor,<br />
refer to <strong>Advance</strong> Form No. HI-4090-R01.<br />
WIRING DIAGRAMS<br />
LI555-IR<br />
DIMENSIONS<br />
5"<br />
LI555-IR<br />
Instant Restrike Ignitor<br />
Catalog Number<br />
LI555-IR<br />
CC-200<br />
2"<br />
Description<br />
Ignitor packed 24 per carton (may order any quantity)<br />
Mounting Clip<br />
12" LEAD LENGTHS<br />
2 1/8"<br />
3/16" DIA.<br />
CC-200<br />
MOUNTING CLIP<br />
LI555-IR<br />
5-50<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Ignitor Specifications<br />
(Case Temperature Rating 105° C)<br />
HID<br />
Metal Halide<br />
Ballast Data<br />
Metal Halide<br />
Standard Ignitor<br />
Long Range Ignitor<br />
<strong>Advance</strong><br />
Ballast<br />
Max.<br />
Lamp ANSI<br />
Catalog<br />
Case Catalog<br />
Min. Max.<br />
Case<br />
Ballast<br />
Circuit<br />
Dist. (ft.)<br />
Dist. (ft) Dist. (ft)<br />
Watts Code<br />
Number<br />
Type Number<br />
Type<br />
Family<br />
Type<br />
To Lamp<br />
To Lamp To Lamp<br />
}<br />
71A5105 50 M110/148 HX LI533-H4-IC 15 Round<br />
71A5181 50 M110/148 HX LI533-H4-IC 10 Round<br />
XTENZA ®<br />
71A5137 50 M110/148 R LI533-H4-IC 2 Round<br />
71A5205 70 M98/143 HX LI533-H4-IC 25 Round<br />
Wide-Range Ignitor<br />
71A52_2 70 M98/143 HX LI533-H4-IC 15 Round<br />
71A5237 70 M98/143 R LI533-H4-IC 10 Round<br />
71A52_1 70 M139 HX LI533-H4-IC 10 Round<br />
71A53_0 100 M90/140 HX LI533-H4-IC 20 Round<br />
71A5383 100 M90/140 CWA LI533-H4-IC 2 Round<br />
71A5337 100 M90/140 R LI533-H4-IC 2 Round<br />
71A54_2 150 M102/142 HX LI533-H4-IC 10 Round LI533-LR 0 - 50 ft Oval<br />
71A5437 150 M102/142 R LI533-H4-IC 2 Round<br />
71A55_3 175 M137/152 SuperCWA LI533-H4-IC 2 Oval<br />
71A56_2 200 M136 SuperCWA LI533-H4-IC 2 Round<br />
71A56_3 200 M136 SuperCWA LI533-H4-IC 5 Round<br />
71A57_2 250 M138/153 SuperCWA LI533-H4-IC 5 Round<br />
Meets ANSI pulse requirements<br />
71A58_2 320 M132/154 SuperCWA LI533-H4-IC 2 Round<br />
for all ballast to lamp distances<br />
71A59_3 350 M131 SuperCWA LI533-H4-IC 2 Round<br />
from 0 to 50 ft.<br />
71A60_2 400 M135/155 SuperCWA LI533-H4-IC 10 Round<br />
71A61E6 400 M135/155 SuperCWI LI533-H4-IC 2 Round<br />
Features 105°C case<br />
71A63_3 450 M144 Super CWA LI533-H4-IC 5 Round<br />
temperature rating<br />
71A55_4 175 M137/152 Reg Lag LI534-H5-IC 20 Oval<br />
}<br />
See Ordering Information Below<br />
71A5634 200 M136 Reg Lag LI534-H5-IC 2 Oval<br />
71A57_4 250 M138/153 Reg Lag LI533-H4-IC 2 Oval<br />
71A60_4 400 M128/135/155 Reg Lag LI534-H5-IC 10 Oval<br />
71A6334 450 M144 Reg Lag LI534-H5-IC 2 Oval LI533-LR3 ★ 0 - 50 ft Oval<br />
71A64_0 750 M149 SuperCWA LI573-H5 15 Oval<br />
71A64_2 750 M149 SuperCWA LI573-H5-IC 15 Oval<br />
71A64_8 875 M-TBD SuperCWA LI572-H5-IC★ 10 Oval<br />
71A65_1 1000 M141 SuperCWA LI572-H5-IC★ 10 Oval<br />
71A65_3 1000 M141 SuperCWA LI571-H5-IC★ 5 Oval<br />
71A50_5 35 M130 HX LI533-H4-IC 15 Round LI561-H5★ 15 50 Oval<br />
71A5081 35 M130 HX LI533-H4-IC 15 Round LI561-H5★ 15 50 Oval<br />
71A5037 35 M130 R LI533-H4-IC 10 Round LI561-H5★ 10 50 Oval<br />
71A52_0 70 M85 HX LI522-H5-IC★ 30 Oval<br />
Not Available<br />
71A54A3 150 M102/142 SuperCWA LI501-J4-IC★ 15 Round<br />
Not Available<br />
71A54_0 150 M81 HX LI522-H5-IC★ 20 Oval<br />
Not Available<br />
71A5486 150 M81 CWA LI523-H5-IC★ 2 Oval<br />
Not Available<br />
71A5880 250 M80 HX LI522-H5-IC★ 5 Oval<br />
Not Available<br />
71A86_5 750 ** CWA LI561-H5-IC★ 5 Oval<br />
Not Available<br />
71A69_0 2000 M134 CWA LI571-H5-IC★ 5 Oval LI571-J5★ 20 40 Oval<br />
**<br />
- Retrofit for S111<br />
★ Equipped with an auto-rest thermal protector to prevent<br />
ignitor from overheating in the event of lamp failure<br />
XTENZA Ordering Information<br />
To order in bulk, specify item no. LI533-LR or<br />
LI533-LR3. For individual carton, add -IC to item no.<br />
XTENZA is also available packaged with the ballasts<br />
shown at right.<br />
Includes core & coil ballast, capacitor and XTENZA.<br />
<strong>Ballasts</strong> are available with or without welded mounting<br />
bracket. Add appropriate suffix to ballast number.<br />
Round Case<br />
WHITE (X2)<br />
RED (X1)<br />
BLUE (X3)<br />
Round Case<br />
= 2"<br />
LI551-H4<br />
All Others= 2 1 /2"<br />
= 2 1 /8”<br />
All others 2 1 /2”<br />
1 1 /4" DIAMETER<br />
2 5 /32"<br />
Max. case temp. 90 o C<br />
Case must be grounded<br />
4 1 /4"<br />
4 3 /4"<br />
Oval Ignitor<br />
Case<br />
3"<br />
Oval Case<br />
1 5 /16"<br />
1/4" SLOT<br />
RED (X1)<br />
WHITE (X2)<br />
BLUE (X3)<br />
CC-125<br />
MOUNTING CLIP for Round Case (Furnished<br />
as standard with -001 suffix ballasts and all<br />
-IC suffix replacement ignitors.<br />
1"<br />
Lamp<br />
Watts<br />
ANSI<br />
Code<br />
Ballast<br />
Number<br />
50 M110/148 71A5105<br />
50 M110/148 71A5181<br />
70 M98/143 71A5205<br />
70 M98/143 71A5292<br />
70 M139 71A5281<br />
100 M90/140 71A5383<br />
100 M90/140 71A5390<br />
150 M102/142 71A5492<br />
175 M137/152 71A5593<br />
200 M136 71A5692<br />
250 M138/153 71A5792<br />
320 M132/154 71A5892<br />
350 M131 71A5993<br />
400 M135/155 71A6092<br />
450 M144 71A6393<br />
750 M149 71A64E2<br />
1000 M141 71A6593<br />
No<br />
Bracket<br />
-900DP<br />
-900D<br />
-900DP<br />
-900D<br />
-900D<br />
-900D<br />
-900D<br />
-900D<br />
-900D<br />
-900D<br />
-900D<br />
-900D<br />
-900D<br />
-900D<br />
-900D<br />
-900D<br />
-900<br />
With Welded<br />
Bracket<br />
-910DP<br />
-910D<br />
-910DP<br />
-910D<br />
-910D<br />
-910D<br />
-910D<br />
-910D<br />
-910D<br />
-910D<br />
-910D<br />
-910D<br />
-910D<br />
-910D<br />
-910D<br />
-910D<br />
-910<br />
HID • IGNITORS<br />
METAL HALIDE<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-51
HIGH INTENSITY DISCHARGE BALLASTS<br />
LISOD<br />
The <strong>Advance</strong> shut-off device (LISOD TM ) enhances the<br />
reliability of High Intensity Discharge (HID) lighting systems<br />
where ignitors are utilized to start the HID lamps. This includes<br />
all high pressure sodium lamps as well as all low, medium, and<br />
high wattage pulse-start metal halide lamps.<br />
The LISOD shut-off device increases the life of the ignitor by<br />
disabling it from the circuit and eliminates any concern over<br />
long-term ballast reliability due to continuously pulsing<br />
ignitors when a lamp is burned out. The LISOD provides a<br />
simple solution to eliminate lamp cycling typically associated<br />
with lamps that have reached their end of life. The LISOD<br />
disables the ignitor after 15 minutes of pulsing in cases when<br />
lamp is taken out of socket or lamp fails to ignite.<br />
> Compatible with any <strong>Advance</strong> Reactor (R), High-Reactance (HX),<br />
and Constant Wattage Autotransformer (CWA) ballast and ignitor<br />
circuit that includes a 120V input tap.<br />
> Integral timer automatically disables ignitor from ballast circuit<br />
15-minutes after power is applied to the ballast<br />
> Extends ignitor life, which is typically rated for 10,000 hours of<br />
continuous pulsing<br />
> Protects ballast coil insulation from potential damage due to a<br />
continuously pulsing ignitor<br />
> Prevents cycling of end-of-life lamps making identification for<br />
lamp replacement easy<br />
> Automatically resets/restarts itself after 0.6 second of power<br />
interruption (voltage dropout)<br />
Catalog<br />
Number<br />
Catalog<br />
Number<br />
Quantity<br />
Per Carton<br />
Lead Lengths are 12”<br />
VLINE<br />
LAMP<br />
LISOD1-IC<br />
Ignitor shut-off device for HID CWA, HX,<br />
and R ballasts with ignitors.<br />
Individual carton packaging<br />
1<br />
120V<br />
X3<br />
X1 LAMP<br />
IGNITOR<br />
X2 COM<br />
LISOD1<br />
Ignitor shut-off device for HID CWA,<br />
HX and R ballasts with ignitors.<br />
Bulk packaging<br />
50<br />
COM<br />
120V (RED)<br />
X2 COM (WHITE)<br />
LISOD<br />
COM (WHITE)<br />
COM<br />
HID • CORE & COIL<br />
Lamp Ignitors Square Plug-in<br />
Assemblies<br />
Square Plug-in ignitor assemblies for use by the HID<br />
fixture manufacturing community to help simplify the lighting<br />
maintenance process.<br />
Designed to make it easier to maintain, assemble, test,<br />
and replace ignitors in magnetic HID fixtures, the Square Plugin<br />
ignitor assembly is electrically identical to <strong>Advance</strong>'s standard<br />
ignitors (e.g., models LI501-H4, LI551-H4, or LI533-H4),<br />
but is housed in a special mechanical enclosure with 3 tab<br />
terminals. Offering added convenience and freedom of choice,<br />
<strong>Advance</strong>'s Square Plug-in ignitor assembly is designed for use<br />
anywhere that its standard ignitor packaging is placed, and<br />
serves as a direct replacement or enhanced alternative to the<br />
standard product for greater simplicity and ease of use.<br />
The following three Square Plug-in ignitor assemblies are<br />
currently available from <strong>Advance</strong>:<br />
> Square Plug-in ignitor assembly for high pressure sodium<br />
(HPS) lamps 150 Watts and up (100V) -- [catalog number<br />
LI501-SQR]<br />
> Square Plug-in ignitor assembly for 35-150 Watt (55V) high<br />
pressure sodium (HPS) lamps--[catalog number LI551-SQR]<br />
> Square Plug-in ignitor assembly for 50-400 Watt metal<br />
halide lamps (85 to 135V)--[catalog number LI533-SQR]<br />
Catalog<br />
Number<br />
LI5xxSQR<br />
Catalog<br />
Number<br />
Complete Ignitor and<br />
Receptacle Assembly<br />
Quantity<br />
Per Carton<br />
LI5xxSQ Ignitor only 70<br />
50<br />
5-52<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Ignitor Specifications<br />
(Case Temperature Rating 105° C)<br />
High Pressure Sodium<br />
High Pressure Sodium<br />
Ballast Data<br />
Standard Ignitor<br />
Long Range Ignitor<br />
<strong>Advance</strong><br />
Ballast<br />
Family<br />
Lamp<br />
Watts<br />
ANSI<br />
Code<br />
Ballast<br />
Circuit<br />
Type<br />
Catalog<br />
Number<br />
Max.<br />
Dist. (ft.)<br />
To Lamp<br />
Case<br />
Type<br />
Catalog<br />
Number<br />
Max.<br />
Dist. (ft.)<br />
To Lamp<br />
Case<br />
Type<br />
HID • IGNITORS<br />
HPS<br />
RED (X1)<br />
71A7707 35 S76 R LI551-H4-IC 2 Round LI551-J4-IC 15 Round<br />
71A77_5 35 S99 Hybrid 6C035-IC* 2 Rect Not Available<br />
71A7801 50 S68 HX LI551-H4-IC 2 Round LI551-J4-IC 35 Round<br />
71A7807 50 S68 R LI551-H4-IC 2 Round LI551-J4-IC 15 Round<br />
71A78_5 50 S104 Hybrid 6C050-IC* 2 Rect. Not Available<br />
71A79_0 70 S62 Reg Lag LI551-H4-IC 2 Round LI551-J4-IC 20 Round<br />
71A79_1 70 S62 HX LI551-H4-IC 2 Round LI551-J4-IC 35 Round<br />
71A79_6 70 S62 CWI LI551-J4-IC 2 Round Not Available<br />
71A79_8 70 S62 CWA LI551-J4-IC 5 Round Not Available<br />
71A7907 70 S62 R LI551-H4-IC 2 Round LI551-J4-IC 15 Round<br />
71A80_0 100 S54 Reg Lag LI551-H4-IC 2 Round LI551-J4-IC 35 Round<br />
71A80_1 100 S54 HX LI551-H4-IC 2 Round LI551-J4-IC 35 Round<br />
71A80_8 100 S54 CWA LI551-J4-IC 5 Round Not Available<br />
71A8007 100 S54 R LI551-H4-IC 2 Round LI551-J4-IC 15 Round<br />
71A80_6 100 S54 CWI LI551-J4-IC 2 Round Not Available<br />
71A80_5 100 S105 Hybrid 6C100-IC* 2 Rect. Not Available<br />
71A81_0 150 S55 Reg Lag LI551-H4-IC 2 Round LI551-J4-IC 40 Round<br />
71A81_2 150 S55 HX LI551-H4-IC 2 Round LI551-J4-IC 35 Round<br />
71A81_8 150 S55 CWA LI551-J4-IC 10 Round Not Available<br />
71A8107 150 S55 R LI551-H4-IC 2 Round LI551-J4-IC 15 Round<br />
71A8156 150 S55 CWI LI551-J4-IC 2 Round Not Available<br />
71A85_5 150 S55 CWI LI551-J4-IC 2 Round Not Available<br />
71A81_6 150 S56 CWA LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />
71A86_7 150 S56 R LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />
*<br />
- Case temperature rating is 80°C only.<br />
Round Case<br />
2 5 /32"<br />
Oval Ignitor<br />
Case<br />
3"<br />
Oval Case<br />
1 5 /16"<br />
RED (X1)<br />
WHITE (X2)<br />
BLUE (X3)<br />
WHITE (X2)<br />
Round Case<br />
1 1 /4" DIAMETER<br />
4 1 /4"<br />
4 3 /4"<br />
1"<br />
BLUE (X3)<br />
LI551-H4 = 2" 2 1 /8”<br />
All All Others= others 22 1 /2”<br />
1 /2"<br />
case temp. 90 o C<br />
must be grounded<br />
1/4" SLOT<br />
4 3 /16"<br />
White Son<br />
Controlle<br />
Rectangular<br />
Case<br />
CC-125<br />
MOUNTING CLIP for Round Case<br />
(Furnished as standard with -001<br />
suffix ballasts and all -IC suffix<br />
replacement ignitors.<br />
White SON<br />
Controller<br />
3 1 /16"<br />
emp. 80 o C<br />
e grounded.<br />
1 11 /16"<br />
5-53<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Ignitor Specifications<br />
(Case Temperature Rating 105° C)<br />
HID<br />
High Pressure Sodium<br />
High Pressure Sodium<br />
Ballast Data<br />
Standard Ignitor<br />
Long Range Ignitor<br />
<strong>Advance</strong><br />
Ballast<br />
Family<br />
Lamp<br />
Watts<br />
ANSI<br />
Code<br />
Ballast<br />
Circuit<br />
Type<br />
Catalog<br />
Number<br />
Max.<br />
Dist. (ft.)<br />
To Lamp<br />
Case<br />
Type<br />
Catalog<br />
Number<br />
Max.<br />
Dist. (ft.)<br />
To Lamp<br />
Case<br />
Type<br />
71A89_0 200 S66 CWA LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />
71A89_1 200 S66 CWA LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />
71A89_4 200 S66 Reg Lag LI501-H4-IC 2 Round LI501-J4-IC 40 Round<br />
71A89_7 200 S66 R LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />
71A82_0 250 S50 Reg Lag LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />
71A82_1 250 S50 CWA LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />
71A82_6 250 S50 CWI LI501-J4-IC 2 Round Not Available<br />
71A82_7 250 S50 R LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />
71A8392 250 S50 CWA LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />
71A83_0 310 S67 Reg Lag LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />
71A83_1 310 S67 CWA LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />
71A83_7 310 S67 R LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />
71A84_0 400 S51 Reg Lag LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />
71A84_3 400 S51 CWA LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />
71A84_6 400 S51 CWI LI501-J4-IC 2 Round Not Available<br />
71A84_7 400 S51 R LI501-H4-IC 2 Round LI501-J4-IC 50 Round<br />
71A85_6 430 n/a CWI LI501-H4-IC 15 Round LI501-J4-IC 35 Round<br />
71A85_5 600 S106 CWA LI561-H5-IC 5 Oval Not Available<br />
71A85_8 600 S106 CWI LI561-H5-IC 2 Oval Not Available<br />
71A86_5 750 S111 CWA LI561-H5-IC 5 Oval Not Available<br />
71A87_3 1000 S52 CWA LI571-H5-IC★ 15 Oval LI571-J5-IC★ 75 Oval<br />
★ Equipped with an auto-rest thermal protector to prevent<br />
ignitor from overheating in the event of lamp failure.<br />
RED (X1)<br />
Round Case<br />
2 5 /32"<br />
Oval Ignitor<br />
Case<br />
3"<br />
1 5 /16"<br />
Oval Case<br />
RED (X1)<br />
WHITE (X2)<br />
BLUE (X3)<br />
HID • IGNITORS<br />
HPS<br />
WHITE (X2)<br />
BLUE (X3)<br />
Round Case<br />
1 1 /4" DIAMETER<br />
Max. case temp. 90 o C<br />
Case must be grounded<br />
4 1 /4"<br />
4 3 /4"<br />
1/4" SLOT<br />
1"<br />
LI551-H4<br />
LI551-H4 =<br />
2"<br />
2 1 /8”<br />
All<br />
All<br />
Others=<br />
others 2 1 /2”<br />
1 /2"<br />
White Son<br />
Controller<br />
Rectangular Case<br />
4 3 /16"<br />
CC-125<br />
MOUNTING CLIP for Round Case<br />
(Furnished as standard with -001<br />
suffix ballasts and all -IC suffix<br />
replacement ignitors.<br />
3 1 /16"<br />
case temp. 80 o C<br />
must be grounded.<br />
1 11 /16"<br />
White SON Controller<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-54
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Transformers & Autotransformers<br />
Stepdown Transformers and Autotransformers<br />
Lamp Type<br />
Lamp<br />
Watts<br />
Input: Output<br />
(Volts)<br />
Catalog ✝<br />
Number<br />
Max.<br />
Input<br />
Current<br />
Max.<br />
Watt<br />
Input<br />
Max.<br />
V.A.<br />
Load<br />
Wiring<br />
Diagram<br />
Dimensions<br />
Fig A B<br />
Weight<br />
(lbs)<br />
TRANSFORMERS<br />
AUTOTRANSFORMERS<br />
Stepdown Transformers for 6 and 12 volt Halogen Lighting<br />
120 120:6.0 71A9325 1.3 156 120 T-1 1 1.2 2.5 3.8<br />
50<br />
71A9742 (-J) .6 50 50 T-1 9 (11) 1.3 2.5(3.3) 2.0(2.3)<br />
HALOGEN<br />
120:11.5<br />
75 71A9743 (-J) .8 81 75 T-1 9 (11) 1.5 2.8(3.5) 2.5(2.8)<br />
50/75 277:11.8 71A9833 (-J) .3/.4 60/86 75 T-1 9 (11) 1.5 2.8(3.5) 2.5(2.8)<br />
Stepdown Autotransformers for 120 volt Incandescent Lighting<br />
150<br />
71A9749 .6 150 150 T-2 9 1.5 2.7 2.3<br />
INCANDESCENT 200 277:115 71A9839 (-J) .8 199 200 T-2 9 (11) 2.2 3.8(4.2) 3.8(4.1)<br />
300 71A9741 (-J) 1.1 300 300 T-2 9 (11) 2.0 3.5(4.0) 3.5(3.8)<br />
Stepdown & Step-up Autotransformers for use with HID Reactor <strong>Ballasts</strong><br />
35/50/70<br />
71A9740 1.1 99 190 T-2 9 1.5 2.8 2.5<br />
277:120<br />
HIGH PRESSURE 100/150 71A9744 2.1 190 385 T-2 9 2.3 3.5 4.0<br />
SODIUM 35/50/70 347:120 71A9885 .9 100 190 T-2 9 1.7 3.9 4.5<br />
100/150 347:120/277 71A9862 1.7 200 395 T-2 9 2.7 3.9 4.5<br />
HPS WHITE SON 35<br />
71A9846 (-J) .4 50 110 T-2 9 (11) 1.8 3.1(3.8) 3.5(3.8)<br />
(See pages 5-32, 50 277:120 71A9847 (-J) .6 72 155 T-2 9 (11) 2.4 3.8(4.4) 4.0(4.3)<br />
5-33, 5-36) 100 71A9876 (-J) .9 125 265 T-2 4 (11) 1.9 2.6(3.9) 6.5(6.8)<br />
50<br />
71A9877 1.6 80 190 T-4 9 1.5 2.8 2.5<br />
METAL HALIDE<br />
70 120:277 71A9900 2.5 85 250 T-4 9 1.9 3.4 3.3<br />
100 71A9741 (-J) 2.4 125 300 T-4 9 (11) 2.0 3.5(4.0) 3.5(3.8)<br />
50/100/150 347:120/277 71A9862 (-J) 1.7 200 395 T-2 9 (11) 2.7 3.9(4.7) 4.5(4.8)<br />
✝ Ordering information:<br />
Add proper suffix to catalog number:<br />
-600 includes core and coil only<br />
-610 includes core and coil with welded bracket<br />
-J (available where shown) includes J-Box cover and auto-reset thermal protection. Refer to Figure 11.<br />
LINE V<br />
OUTPUT V<br />
INCANDESCENT<br />
LAMP<br />
B<br />
MAX.<br />
A<br />
2 13 /16"<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
3 /4"<br />
B<br />
MAX.<br />
2 3 /16"<br />
B<br />
A<br />
A<br />
2 3 /16"<br />
4 Holes cleared for<br />
#6 thru-bolts<br />
2 5 /8" Fig. 9<br />
(2 5 /8" x 2 3 /16 Reactor Core )<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
LINE V<br />
OUTPUT V<br />
Fig. T-1<br />
2 13 /16"<br />
LINE V<br />
VOLTS<br />
LAMP<br />
REACTOR<br />
OUTPUT V<br />
INCANDESCENT<br />
LAMP<br />
BALLAST<br />
HID<br />
CAP (OPTIONAL)<br />
LAMP<br />
2 7 /16"<br />
3 1 /2" 3 15 /16"<br />
Fig. 1<br />
(3" x 4" core)<br />
2 1 /4"<br />
2 13 /16"<br />
3 3 /8" Fig. 4<br />
(2 13 /16 " x 3 3 /8 Reactor Core )<br />
COM<br />
COM<br />
COM<br />
COM<br />
Fig. T-2<br />
B<br />
2 3 / 16 "<br />
OUTPUT V<br />
VOLTS<br />
LAMP<br />
A<br />
1 27 / 32 "<br />
LINE V<br />
COM<br />
COM<br />
REACTOR<br />
BALLAST<br />
HID<br />
CAP (OPTIONAL)<br />
LAMP<br />
COM<br />
COM<br />
Fig. T-4<br />
1 / 2 "<br />
1 / 2 "-14<br />
STRAIGHT PIPETHREAD<br />
2 5 / 8 "<br />
Fig. 11<br />
J-Box Ballast<br />
1 13 / 16<br />
WELDED BRACKET DIMENSIONS<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
1 5.1 1.00 4.50 0.25<br />
4, 9 4.0 0.75 3.50 0.28<br />
5-55<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
F-Can <strong>Ballasts</strong>, Indoor, Outdoor Type 1<br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
HID<br />
Mercury<br />
Input<br />
Voltage<br />
100 Watt Lamp, ANSI Code H38/H44<br />
72C2584-NP<br />
120/277<br />
1.0/.5 1.0/.5 .7/.3 118 245 3/2<br />
8.5<br />
72C2584-NP-001 CWA<br />
11.75 10.50 11.13<br />
✪ ✓ ✓<br />
120/347 72C25C4-NP 1.0/.4 1.0/.4 .4/.2 119 235 3/1 8.5<br />
✓<br />
125 Watt Lamp, ANSI Code H42 SOUND RATING B<br />
120/347 72C29C4-NP CWA 1.4/.5 1.4/.5 .4/.2 150 245 4/2 11.75 10.50 11.13 8.5 ✪<br />
✓<br />
175 Watt Lamp, ANSI Code H39 SOUND RATING B<br />
72C3084-NP<br />
120/277<br />
1.7/.8 1.7/.7 .7/.3 200 245 5/3<br />
10.5<br />
72C3084-NP-001 CWA<br />
11.75 10.50 11.13<br />
✪ ✓ ✓<br />
120/347 72C30C4-NP 1.7/.6 1.7/.6 .7/.3 5/2<br />
✓<br />
250 Watt Lamp, ANSI Code H37 SOUND RATING B<br />
120/277<br />
400 Watt Lamp, ANSI Code H33 SOUND RATING C<br />
120/277<br />
Catalog<br />
Number<br />
72C3584-NP<br />
72C3584-NP-001<br />
72C4083-NP<br />
72C4083-NP-001<br />
Circuit<br />
Type<br />
Operating<br />
Input Amps<br />
Starting<br />
Open<br />
Circuit<br />
Input<br />
Watts<br />
Nom.<br />
Open<br />
Circuit<br />
Voltage<br />
✝ Ordering information:<br />
Replacement ballasts in individual cartons indicated by bold type with suffix -001.<br />
Fuse<br />
Rating<br />
Amps<br />
Over-all Case<br />
Length Length<br />
All <strong>Advance</strong> dual-volt, F-can ballasts include auto-reset thermal protection for both taps.<br />
✪ Ballast to lamp distance is only limited by the size of the conductor between the ballast and the lamp. For proper wire<br />
size, see table on page 5-50 of this catalog.<br />
Mtg.<br />
Dim.<br />
Total<br />
Wt.<br />
(lbs)<br />
Max.<br />
Ballast to<br />
Lamp<br />
Distance (ft)<br />
Certifications<br />
SOUND RATING B<br />
CWA 2.5/1.1 2.5/1.1 1.1/.5 280 245 7/3 14.30 13.13 13.75 14.5 ✪ ✓ ✓<br />
CWA 3.9/1.7 3.6/1.6 1.1/.5 450 245 10/5 19.20 18.00 18.63 20.5 ✪ ✓ ✓<br />
2 ⁵⁄₈"<br />
3³⁄₁₆"<br />
CASE LENGTH<br />
MOUNTING<br />
OVERALL LENGTH<br />
LEAD LENGTHS 12"<br />
Wiring Diagram<br />
All lead lengths 12”<br />
HID • F-CAN<br />
2"<br />
⁵⁄₁₆" Slots<br />
F-Can Ballast<br />
Dimensions<br />
Accessories<br />
PKG-625<br />
Mounting Bracket Kit<br />
Includes (2) mounting brackets<br />
and (4) #10-32 screws with<br />
nuts and washers.<br />
PC-161<br />
Lead Cover (TeePee Type)<br />
PC-857<br />
Wiring Compartment<br />
For end mounting, includes<br />
(5) ⁷⁄₈” dia. knockouts. May be used<br />
with or without PC-625 Mtg. Brkt. Kit<br />
³⁄₈"<br />
2"<br />
4"<br />
4¹⁄₂"<br />
⁵⁄₈"<br />
I l d (2) i b k<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-56
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
F-Can <strong>Ballasts</strong>, Indoor, Outdoor Type 1<br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
Metal Halide<br />
HID • F-CAN<br />
New<br />
New<br />
New<br />
New<br />
New<br />
New<br />
Nom.<br />
Max.<br />
Input Amps<br />
Fuse<br />
Total<br />
Certifications<br />
Input Catalog Circuit<br />
Input Open Over-all Case Mtg. Ballast to<br />
Rating<br />
Wt.<br />
Voltage Number Type<br />
Open<br />
Watts Circuit Length Length Dim.<br />
Lamp<br />
Operating Starting<br />
Amps<br />
(lbs)<br />
Circuit<br />
Voltage<br />
Distance (ft)<br />
35/39 Watt Lamp, ANSI Code M130 SOUND RATING B<br />
72C5005-NP<br />
120<br />
72C5005-NP-BLS* HX-HPF .5 .5 .8 49 230 2 8.50 7.31 7.90 4.0 5 ✓ ✓<br />
120/277 72C5081-NP HX-HPF .6/.3 .6/.3 1.0/.4 56 255 3/1 11.75 10.50 11.13 9.0 10 ✓ ✓<br />
50 Watt Lamp, ANSI Code M110 or M148 SOUND RATING B<br />
72C5181-NP<br />
✓ ✓<br />
120/277<br />
.7/.3 .8/.4 1.2/.5 72 254 3/2<br />
25<br />
72C5181-NP-001 HX-HPF<br />
11.75 10.50 11.13 9.0<br />
✓<br />
120/347 72C51C1-NP .6/.2 .5/.2 1.6/.6 67 277 4/2<br />
20 20 20<br />
70 Watt Lamp, ANSI Code M85 (Double-ended lamp) SOUND RATING B<br />
72C5280-NP<br />
120/277<br />
.9/.4 1.0/.5 1.7/.8<br />
10 ✓ ✓<br />
72C5280-NP-001 HX-HPF<br />
94 240 5/2 11.75 10.50 11.13 8.5<br />
120/347 72C52C0-NP .8/.3 1.0/.4 1.7/.6<br />
35 ✓<br />
70 Watt Lamp, ANSI Code M98 or M143 SOUND RATING B<br />
72C5282-NP<br />
10 ✓ ✓<br />
120/277 72C5282-NP-001 .9/.4 1.3/.6 1.6/.8<br />
4/2<br />
HX-HPF 94 255<br />
11.75 10.50 11.13 8.5<br />
72C5282-NP-900 • 50<br />
✓<br />
120/347 72C52C2-NP .9/.3 1.2/.4 1.7/.7 5/2 20<br />
✓<br />
70 Watt Lamp, ANSI Code M139 SOUND RATING B<br />
72C5281-NP<br />
5<br />
120/277<br />
.9/.4 1.0/.5 1.7/.8 94 240 5/2 11.75 10.50 11.13 8.5<br />
✓ ✓<br />
72C5281-NP-900 • HX-HPF<br />
50<br />
120/347 72C52C1-NP-900 • .8/.3 1.0/.4 1.7/.6 94 255 5/2 11.75 10.50 11.13 8.5 50 ✓ ✓<br />
100 Watt Lamp, ANSI Code M90 or M140 SOUND RATING B<br />
72C5381-NP<br />
15<br />
120/277 72C5381-NP-001 1.1/.5 2.2/1.0 2.4/1.1<br />
6/3<br />
✓ ✓<br />
HX-HPF 125 277<br />
11.75 10.50 11.13 11.0<br />
72C5381-NP-900 •<br />
50<br />
120/347 72C53C1-NP 1.1/.4 2.2/.8 2.4/.9 6/2 15<br />
✓<br />
150 Watt Lamp, ANSI Code M81 (Double-ended lamp) SOUND RATING B<br />
120/277 72C5481-NP<br />
1.6/.7 1.7/.8 3.7/1.6<br />
✓ ✓<br />
HX-HPF<br />
180 240 10/4 14.30 13.13 13.75 13.0 10<br />
120/347 72C54C1-NP 1.6/.6 1.7/.6 3.7/1.3<br />
✓<br />
150 Watt Lamp, ANSI Code M102 or M142 SOUND RATING B<br />
72C5482-NP<br />
5<br />
120/277<br />
1.6/.7 1.5/.8 3.7/1.6 180 277 10/4 14.30 13.13 13.75 13.0<br />
✓ ✓<br />
72C5482-NP-900 • HX-HPF<br />
50<br />
120/347 72C54C2-NP-900 • 1.6/.6 1.7/.6 3.7/1.3 180 240 10/4 14.30 13.13 13.75 13.0 50 ✓<br />
All <strong>Advance</strong> dual-volt, F-can ballasts include auto-reset thermal protection for both taps.<br />
* Ballast with suffix -BLS includes bottom leads with studs.<br />
✪ Ballast to lamp distance is only limited by the size of the conductor between the ballast and the lamp. For proper wire<br />
size, see table on page 5-50 of this catalog.<br />
Replacement ballasts in individual cartons indicated by bold type with suffix -001.<br />
Wiring Diagram<br />
• <strong>Ballasts</strong> with suffix -900 include integral XTENZA ® Wide-Range Ignitor for 50 ft. max. ballast to lamp distance. All lead lengths 12”<br />
CASE LENGTH<br />
CASE LENGTH<br />
5-57<br />
1 11 /16”<br />
1 11 /16”<br />
2 3 /8”<br />
⁵⁄₁₆" Slots<br />
OVERALL LENGTH<br />
MOUNTING<br />
LEAD LENGTHS 12"<br />
Dimensions<br />
(72C5005-NP)<br />
2 5 /8” ⁵⁄₈"<br />
2"<br />
3³⁄₁₆"<br />
⁵⁄₁₆" Slots<br />
MOUNTING<br />
OVERALL LENGTH<br />
LEAD LENGTHS 12"<br />
Dimensions<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
F-Can <strong>Ballasts</strong>, Indoor, Outdoor Type 1<br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
HID<br />
Metal Halide<br />
Input<br />
Voltage<br />
Catalog<br />
Number<br />
Circuit<br />
Type<br />
Operating<br />
Input Amps<br />
Starting<br />
Open<br />
Circuit<br />
Input<br />
Watts<br />
Nom.<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
Amps<br />
Over-all Case<br />
Length Length<br />
Mtg.<br />
Dim.<br />
Total<br />
Wt.<br />
(lbs)<br />
Max.<br />
Ballast to<br />
Lamp<br />
Distance (ft)<br />
Certifications<br />
175/150 Watt Lamp, ANSI Code M57 or H39/M107 SOUND RATING B<br />
72C5581-NP<br />
120/277<br />
2.0/.9 2.0/.9 1.4/.7 205<br />
5/3<br />
✓ ✓<br />
72C5581-NP-001 CWA<br />
300<br />
11.75 10.50 11.13 12.0 ✪<br />
120/347 72C55C1-NP 1.9/.7 1.9/.7 1.7/.5 208 5/2<br />
✓<br />
175 Watt Lamp, ANSI Code M137 or M152 (Pulse-Start) SOUND RATING B<br />
72C5582-NP• Super<br />
120/277<br />
1.7/.8 .9/.4 2.2/.9 205 300 5/3 14.30 13.13 13.75 15.5 50 ✓ ✓<br />
72C5582-NP-001• CWA<br />
250 Watt Lamp, ANSI Code M58 or H37 SOUND RATING C<br />
120/277 72C5782-NP<br />
2.6/1.1 2.1/.9 2.1/.9<br />
8/4 16.70 15.50 16.13 16.0<br />
✓ ✓<br />
120/277 72C5782-NP-001 CWA<br />
290 300<br />
✪<br />
120/347 72C57C2-NP 2.5/.9 2.0/.7 2.0/.7 7/3 14.30 13.13 13.75 14.0 ✓<br />
250 Watt Lamp, ANSI Code M138 or M153 (Pulse-Start) SOUND RATING B<br />
72C5783-NP• Super<br />
120/277<br />
2.8/1.2 2.5/1.1 1.9/.8 290 300 8/3 16.70 15.50 16.13 18.0 50 ✓ ✓<br />
72C5783-NP-001• CWA<br />
320 Watt Lamp, ANSI Code M132 or M154 (Pulse-Start) SOUND RATING C<br />
72C5882-NP• Super<br />
120/277<br />
3.4/1.5 2.8/1.2 1.6/.7 370 270 8/3 19.20 18.00 18.63 21.0 50 ✓ ✓<br />
72C5882-NP-001• CWA<br />
350 Watt Lamp, ANSI Code M131 (Pulse-Start) SOUND RATING C<br />
72C5983-NP• Super<br />
120/277<br />
3.7/1.7 2.5/1.2 3.9/1.7 410 310 10/4 19.20 18.00 18.63 24.0 50 ✓ ✓<br />
72C5983-NP-001• CWA<br />
400 Watt Lamp, ANSI Code M59 or H33 SOUND RATING C<br />
72C6082-NP<br />
120/277<br />
CWA 3.9/1.7 3.3/1.4 3.9/1.7 460 310 10/5 19.20 18.00 18.63 22.5 ✪ ✓ ✓<br />
72C6082-NP-WC*<br />
400 Watt Lamp, ANSI Code M135 or M155 (Pulse-Start) SOUND RATING C<br />
120/277<br />
72C6182-NP•<br />
72C6182-NP-001•<br />
Super<br />
CWA<br />
4.1/1.8 2.9/1.3 3.9/1.7 465 310 10/4 19.20 18.00 18.63 24.0 50 ✓ ✓<br />
All <strong>Advance</strong> dual-volt, F-can ballasts include auto-reset thermal protection for both taps.<br />
✪ Ballast to lamp distance is only limited by the size of the conductor between the ballast and the lamp. For proper wire<br />
size, see table on page 5-50 of this catalog.<br />
Replacement ballasts in individual cartons indicated by bold type with suffix -001.<br />
* Ballast with suffix WC (white can) is rated for Type 2 Outdoor use.<br />
• Includes integral XTENZA ® Wide-Range Ignitor for 50 ft. max. ballast to lamp distance.<br />
HID • F-CAN<br />
Accessories<br />
PKG-625<br />
Mounting Bracket Kit<br />
Includes (2) mounting brackets<br />
and (4) #10-32 screws with<br />
nuts and washers.<br />
PC-161<br />
Lead Cover (TeePee Type)<br />
PC-857<br />
Wiring Compartment<br />
For end mounting, includes<br />
(5) ⁷⁄₈” dia. knockouts. May be used<br />
with or without PC-625 Mtg. Brkt. Kit<br />
³⁄₈"<br />
2"<br />
4"<br />
4¹⁄₂"<br />
⁵⁄₈"<br />
Includes (2) mounting brackets<br />
and (4) #10 32 screws with nuts<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-58
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
F-Can <strong>Ballasts</strong>, Indoor, Outdoor Type 1<br />
(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />
High Pressure Sodium<br />
Input<br />
Voltage<br />
Catalog<br />
Number<br />
Circuit<br />
Type<br />
Input Amps<br />
Operating Starting<br />
Open<br />
Circuit<br />
Input<br />
Watts<br />
Nom.<br />
Open<br />
Circuit<br />
Voltage<br />
50 Watt Lamp, ANSI Code S68 SOUND RATING B<br />
72C7884-NP<br />
120/277<br />
HX-HPF .7/.3 .7/.4 1.4/.7 65 120 4/2 11.75 10.50 11.13 11.0 15 ✓ ✓<br />
72C7884-NP-001<br />
Fuse<br />
Rating<br />
Amps<br />
Over-all Case<br />
Length Length<br />
Mtg.<br />
Dim.<br />
Total<br />
Wt.<br />
(lbs)<br />
Max.<br />
Ballast to<br />
Lamp<br />
Distance (ft)<br />
Certifications<br />
70 Watt Lamp, ANSI Code S62 SOUND RATING B<br />
72C7984-NP<br />
120/277<br />
.9/.4 1.0/.5 1.4/.7 90<br />
5/2<br />
✓ ✓<br />
72C7984-NP-001 HX-HPF<br />
120<br />
11.75 10.50 11.13 10.0 7<br />
120/347 72C79C4-NP .8/.3 .9/.3 1.4/.5 94 4/2 ✓<br />
100 Watt Lamp, ANSI Code S54 SOUND RATING B<br />
72C8084-NP<br />
120/277<br />
1.1/.5 1.5/.7 1.9/.8<br />
✓ ✓<br />
72C8084-NP-001 HX-HPF<br />
125 120 6/3 11.75 10.50 11.13 11.0 15<br />
120/347 72C80C4-NP 1.2/.4 1.7/.6 1.7/.6 ✓<br />
150 Watt Lamp, ANSI Code S55 (55-Volt Arc Tube) SOUND RATING B<br />
120/277 72C8185-NP<br />
1.7/.7 2.6/1.2 2.2/1.0<br />
✓ ✓<br />
HX-HPF<br />
185 120 8/4 14.30 13.13 13.75 14.0 5<br />
120/347 72C81C5-NP 1.7/.6 2.6/.9 2.2/.8<br />
✓<br />
150 Watt Lamp, ANSI Code S56 (100-Volt Arc Tube) SOUND RATING B<br />
120/277 72C8680-NP CWA 1.7/.7 1.5/.7 1.0/.4 185 186 5/3 14.30 13.13 13.75 14.0 5 ✓ ✓<br />
35 Watt Lamp, ANSI Code S99 (White SON-Philips) (Minimum starting temperature -30°C or -20°F) SOUND RATING B<br />
Hybrid<br />
120 72C7705-NP<br />
.4 .6 .9 45 120 3 11.75 10.50 11.13 6.0 2 ✓ ✓<br />
<strong>Electronic</strong><br />
50 Watt Lamp, ANSI Code S104 (White SON-Philips) (Minimum starting temperature -30°C or -20°F) SOUND RATING B<br />
Hybrid<br />
120 72C7805-NP<br />
.7 1.0 1.3 68 120 3 11.75 10.50 11.13 6.5 2 ✓ ✓<br />
<strong>Electronic</strong><br />
HID • F-CAN<br />
100 Watt Lamp, ANSI Code S105 (White SON-Philips) (Minimum starting temperature -30°C or -20°F) SOUND RATING B<br />
Hybrid<br />
120 72C8005-NP<br />
1.1 2.2 2.0 120 120 5 14.30 13.13 13.75 9.0 2 ✓ ✓<br />
<strong>Electronic</strong><br />
All <strong>Advance</strong> dual-volt, F-can ballasts include auto-reset thermal protection for both taps.<br />
Wiring Diagram<br />
Except for White SON<br />
All lead lengths 12”<br />
2 5 /8” ⁵⁄₈"<br />
3³⁄₁₆"<br />
CASE LENGTH<br />
MOUNTING<br />
OVERALL LENGTH<br />
LEAD LENGTHS 12"<br />
Replacement ballasts in individual cartons indicated by<br />
bold type with suffix -001.<br />
Wiring Diagram<br />
For White SON<br />
All lead lengths 12”<br />
Accessories<br />
PKG-625<br />
Mounting Bracket Kit<br />
Includes (2) mounting brackets<br />
and (4) #10-32 screws with<br />
nuts and washers.<br />
PC-161<br />
Lead Cover (TeePee Type)<br />
2"<br />
⁵⁄₁₆" Slots<br />
Dimensions<br />
PC-857<br />
Wiring Compartment<br />
For end mounting, includes<br />
(5) ⁷⁄₈” dia. knockouts. May be used<br />
with or without PC-625 Mtg. Brkt. Kit<br />
³⁄₈"<br />
2"<br />
4"<br />
4¹⁄₂"<br />
⁵⁄₈"<br />
Includes (2) mounting brackets<br />
and (4) #10 32 screws with nuts<br />
5-59<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Encapsulated Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
HID<br />
Mercury<br />
Input<br />
Volts<br />
Catalog ✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Case<br />
Style<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(lbs)<br />
100 Watt Lamp, ANSI Code H38 SOUND RATING A<br />
120/208/<br />
240/277<br />
73B2591 CWA 125<br />
1.1/.6/<br />
.6/.5<br />
250<br />
✝ Ordering information:<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
• For CWA circuits, figure is operating current.<br />
3/2/<br />
2/2<br />
PC709-2 10 280 7C100M33-R D 8.3<br />
175 Watt Lamp, ANSI Code H39 SOUND RATING A<br />
120/208/<br />
240/277<br />
73B3092 CWA 200<br />
1.9/1.1/<br />
1.0/.9<br />
215<br />
5/3/<br />
3/2<br />
PC709-2 17.5 240 7C175M33-R D 8.3<br />
250 Watt Lamp, ANSI Code H37 SOUND RATING B<br />
120/208/<br />
240/277<br />
73B3592 CWA 285<br />
2.5/1.4/<br />
1.3/1.1<br />
250<br />
8/5/<br />
5/3<br />
PC709-4 22.5 280 7C225P30-R D 12.0<br />
400 Watt Lamp, ANSI Code H33 SOUND RATING B<br />
120/208/<br />
240/277<br />
73B4091 CWA 454<br />
3.9/2.2/<br />
2.0/1.7<br />
245<br />
10/8/<br />
5/5<br />
A<br />
A<br />
A<br />
A<br />
PC767-1 35 240 7C350P30-R D 14.0<br />
LINE V<br />
CAP<br />
CAP<br />
LAMP<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
Fig. A<br />
COM<br />
LAMP<br />
HID • ENCAPSULATED<br />
CORE & COIL<br />
SIDE LEAD EXIT<br />
DIMENSIONS<br />
Case<br />
Style<br />
Lead<br />
Exit<br />
A B C<br />
PC709-2 Side 4.6 3.4 3.6 2.0 5.25 6.0<br />
PC709-4 Side 4.6 4.4 3.6 2.0 5.25 6.0<br />
PC767-1 Side 5.4 5.0 3.8 2.0 6.0 6.75<br />
D<br />
E<br />
F<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-60
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Encapsulated Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
Metal Halide<br />
Input<br />
Volts<br />
Catalog ✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Cap Catalog<br />
Number<br />
70 Watt Lamp, ANSI Code M98 Medium Base SOUND RATING A<br />
120/277 73B5282 HX-HPF 90 1.9/.8 255 4/2 K PC709-2 8 280 7C080L33-R D 9.0 LI533-H4 15<br />
100 Watt Lamp, ANSI Code M90 or M140 SOUND RATING A<br />
120/277<br />
73B5380 HX-HPF 129 2.6/1.2 280 6/3 K PC709-4 12 280 7C120M33-R D<br />
LI533-H4 20<br />
10.0<br />
73B5383 CWA 128 1.1/.5 222 3/2 M PC709-4 10 330 7C100M33-R D<br />
LI533-H4 2<br />
150 Watt Lamp, ANSI Code M102 (Medium Base) or M142 SOUND RATING A<br />
120/277 73B5482 HX-HPF 185 3.7/1.6 265 10/4 K PC709-4 16 280 7C160M33-R D 11.0 LI533-H4 10<br />
175 Watt Lamp, ANSI Code M57 or H39 SOUND RATING A<br />
120/208/<br />
1.8/1.1/<br />
5/3/<br />
73B5590 CWA 210<br />
305<br />
240/277<br />
.9/.8<br />
3/2<br />
A PC709-4 10 400 7C100M40-R D 12.0 — —<br />
120/<br />
1.8/<br />
5/<br />
73B55A0 CWA 210<br />
305<br />
277/347<br />
.8/.7<br />
2/2<br />
A PC709-4 10 400 7C100M40-R D 12.2 — —<br />
250 Watt Lamp, ANSI Code M58 or H37 SOUND RATING B<br />
120/208/<br />
2.5/1.4/<br />
8/5/<br />
73B5790 CWA 295<br />
300<br />
240/277<br />
1.3/1.1<br />
5/3<br />
A PC767-1 15 400 7C150P40-R D 15.0 — —<br />
120/<br />
2.5/<br />
8/<br />
73B57A0 CWA 295<br />
315<br />
277/347<br />
1.1/.9<br />
3/3<br />
A PC767-1 15 400 7C150P40-R D 15.2 — —<br />
Case<br />
Style<br />
Mfd<br />
Min<br />
Volt<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(lbs)<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
250 Watt Lamp, ANSI Code M138 or M153 (Pulse-Start) SOUND RATING B<br />
120/208/<br />
Super<br />
2.5/1.4/<br />
8/5/<br />
73B5792<br />
292<br />
270 M PC767-1 17 330 7C170M33-R D 16.0 LI533-H4 2<br />
240/277<br />
CWA<br />
1.3/1.1<br />
5/3<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
HID • ENCAPSULATED<br />
CORE & COIL<br />
320 Watt Lamp, ANSI Code M132 or M154 (Pulse-Start) SOUND RATING B<br />
120/208/<br />
Super<br />
3.3/1.9/<br />
8/6/<br />
73B5892<br />
368<br />
270 M PC767-3 21 345 7C210P34-R D 18.0 LI533-H4 2<br />
240/277<br />
CWA<br />
1.7/1.4<br />
5/3<br />
350 Watt Lamp, ANSI Code M131 (Pulse-Start) SOUND RATING B<br />
120/208/<br />
240/277<br />
73B5993<br />
Super<br />
CWA<br />
400<br />
3.4/2.0/<br />
1.7/1.5<br />
✝ Ordering information:<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-500 includes core & coil with oil-filled capacitor<br />
-600 core & coil only (no capacitor)<br />
• For CWA circuits, figure is operating current. For HX circuits, figure is<br />
highest of starting, operating or open circuit currents.<br />
✝✝ Each ballast requiring an ignitor is furnished as standard with the Short<br />
Range ignitor model shown for use within fixtures. If a Long Range ignitor<br />
is required for remote mounting, specify on order. See pages 5-50 to 5-53<br />
for additional information.<br />
10/7/<br />
270 M PC767-3 23 345 7C225P34 D 18.0 LI533-H4 2<br />
5/5<br />
5-61<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Encapsulated Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
HID<br />
Metal Halide<br />
Input<br />
Volts<br />
Catalog ✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max • Nom<br />
Fuse<br />
Open<br />
Input<br />
Rating<br />
Circuit<br />
Current (Amps)<br />
Voltage<br />
Wiring<br />
Dia<br />
Case<br />
Style<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Total<br />
Weight<br />
(lbs)<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
400 Watt Lamp, ANSI Code M59 or H33 SOUND RATING B<br />
120/208/<br />
240/277<br />
120/<br />
277/347<br />
73B6091 CWA 458<br />
73B60A1 CWA 460<br />
4.0/2.3/<br />
2.0/1.7<br />
4.0/<br />
1.7/1.4<br />
10/7/<br />
300 A PC767-3 24 400 7C240P40-R D 20.0 — —<br />
5/5<br />
10/<br />
300 A PC767-3 24 400 7C240P40-R D 20.2 — —<br />
5/4<br />
400 Watt Lamp, ANSI Code M135 or M155 (Pulse-Start) SOUND RATING B<br />
120/208/<br />
240/277<br />
10/7/<br />
265 M PC767-3 26 330 7C260P33-R D 18.0 LI533-H4 10<br />
5/5<br />
1000 Watt Lamp, ANSI Code M47 or H36 SOUND RATING C<br />
120/208/<br />
240/277<br />
120/208/<br />
277/347<br />
120/<br />
277/347<br />
73B6092<br />
Super<br />
CWA<br />
452<br />
73B6592 CWA 1080<br />
73B6590 CWA 1070<br />
73B65A2 CWA 1080<br />
3.8/2.2/<br />
1.9/1.7<br />
9.0/5.2/<br />
4.5/3.9<br />
9.0/<br />
3.9/3.2<br />
9.0/<br />
3.9/3.2<br />
Cap Catalog<br />
Number<br />
430<br />
20/15/<br />
10/10<br />
A PC768-2 24 480 MD2409-100 O 28.0 — —<br />
415<br />
20/<br />
10/8<br />
A PC768-2 26 480 MD2409-100 O 28.0 — —<br />
20/<br />
430 A PC768-1 24 480 MD2409-100 O 28.0 — —<br />
10/8<br />
Dry<br />
or<br />
Oil<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
✝ Ordering information:<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-500 includes core & coil with oil-filled capacitor<br />
-600 core & coil only (no capacitor)<br />
• For CWA circuits, figure is operating current. For HX circuits, figure is<br />
highest of starting, operating or open circuit currents.<br />
✝✝ Each ballast requiring an ignitor is furnished as standard with the Short<br />
Range ignitor model shown for use within fixtures. If a Long Range ignitor<br />
is required for remote mounting, specify on order. See pages 5-50 to 5-53<br />
for additional information.<br />
COM<br />
CAP<br />
LINE V<br />
CAP<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
Fig. K<br />
LAMP<br />
X3<br />
IGNITOR<br />
X2<br />
COM<br />
X1<br />
LAMP<br />
LAMP<br />
DIMENSIONS<br />
Case<br />
Style<br />
Lead<br />
Exit<br />
A B C<br />
SIDE LEAD EXIT<br />
PC709-2 Side 4.6 3.4 3.6 2.0 5.25 6.0<br />
PC709-4 Side 4.6 4.4 3.6 2.0 5.25 6.0<br />
PC767-1 Side 5.4 5.0 3.8 2.0 6.0 6.75<br />
PC767-3 Side 5.4 5.0 4.3 2.0 6.0 6.75<br />
PC768-1 Side 6.5 5.0 5.2 2.0 7.0 7.75<br />
PC768-2 Side 6.3 4.9 5.9 2.0 7.0 7.75<br />
D<br />
E<br />
F<br />
HID • ENCAPSULATED<br />
CORE & COIL<br />
LINE V<br />
LINE V<br />
CAP<br />
CAP<br />
LAMP<br />
LINE V<br />
LINE V<br />
X3 X1<br />
IGNITOR<br />
X2<br />
LAMP<br />
LINE V<br />
LINE V<br />
CAP<br />
CAP<br />
CAP<br />
LINE V<br />
LAMP<br />
COM<br />
COM<br />
Fig. M<br />
COM<br />
COM<br />
Fig. A<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-62
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Encapsulated Core & Coil <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />
High Pressure Sodium<br />
Input<br />
Volts<br />
Catalog ✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Case<br />
Style<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(lbs)<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
250 Watt Lamp, ANSI Code S50 SOUND RATING B<br />
120/277 73B8281 CWA 295 2.5/1.1 187 7/3 M PC767-3 35 240 7C350P24 D 15.0 LI501-H4 2<br />
400 Watt Lamp, ANSI Code S51 SOUND RATING B<br />
120/277 73B8483 CWA 460 3.8/1.7 190 10/5 M PC767-3 55 240 7C550P24 D 21.0 LI501-H4 2<br />
50 Watt Lamp, ANSI Code S104 (White SON-Philips) SOUND RATING A<br />
120 73B7805<br />
Hybrid<br />
<strong>Electronic</strong><br />
Reactor<br />
68 1.3 120 3 R PC709-6 28 120<br />
Dry capacitor & controller<br />
potted in can<br />
Internal 2<br />
100 Watt Lamp, ANSI Code S105 (White SON-Philips) SOUND RATING A<br />
120 73B8005<br />
Hybrid<br />
<strong>Electronic</strong><br />
Reactor<br />
120 2.2 120 5 R PC709-6 45 120<br />
Dry capacitor & controller<br />
potted in can<br />
9.0<br />
9.0<br />
Internal 2<br />
HID • ENCAPSULATED<br />
CORE & COIL<br />
✝ Ordering information:<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D (All except White SON) includes core & coil with dry-film capacitor<br />
-510 (White SON only) includes core and coil with dry-film capacitor and<br />
controller potted in can<br />
-600 (All except White SON) core & coil only (no capacitor)<br />
• For CWA circuits, figure is operating current. For Hybrid <strong>Electronic</strong> Reactor<br />
circuits, figure is highest of starting, operating or open circuit current.<br />
✝✝ Each ballast requiring an ignitor is furnished as standard with the Short<br />
Range ignitor model shown for use within fixtures. If a Long Range ignitor is<br />
required for remote mounting, specify on order. See pages 5-50 to 5-53 for<br />
additional information.<br />
LINE V<br />
LINE V<br />
LAMP<br />
LINE V<br />
LINE V<br />
X3 X1<br />
IGNITOR<br />
X2<br />
LAMP<br />
COM<br />
CAP<br />
CAP<br />
CAP<br />
Fig. M<br />
COM<br />
END LEAD EXIT<br />
SIDE LEAD EXIT<br />
120 V<br />
CAP REACTOR<br />
NEUTRAL<br />
LAMP (RED) HV<br />
LAMP<br />
3<br />
CONTROLLER<br />
4<br />
LAMP (BLUE) LV<br />
Fig. R<br />
DIMENSIONS<br />
Case<br />
Style<br />
Lead<br />
Exit<br />
A B C D E F<br />
PC709-6 End 4.6 4.4 3.6 2.0 5.25 6.0<br />
PC709-7 End 4.6 3.4 3.6 2.0 5.25 6.0<br />
PC767-3 Side 5.4 5.0 4.3 2.0 6.0 6.75<br />
5-63<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Postline <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
HID<br />
Mercury<br />
Input<br />
Volts<br />
Catalog Number<br />
(P=Thermally<br />
Protected)<br />
✝<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom. Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
(amps)<br />
Length<br />
(in)<br />
Spring Clip<br />
& Support<br />
Chain Kit<br />
Weight<br />
(lbs)<br />
Certifications<br />
50 Watt Lamp, ANSI Code H46<br />
120 74P1501-011P CWA 76 .7 250 2<br />
12.0<br />
PL-2<br />
(Optional)<br />
6.5<br />
✓<br />
✓<br />
120 74P1801-011 HX-NPF 74 2.0 275 5<br />
7.0<br />
PL-1<br />
(Optional)<br />
5.0<br />
✓<br />
✓<br />
75 Watt Lamp, ANSI Code H43<br />
120 74P2001-011P CWA 95 .9 240 2<br />
12.0<br />
PL-2<br />
(Optional)<br />
6.5<br />
✓<br />
✓<br />
120 74P2301-011 HX-NPF 92 2.1 250 6<br />
7.0<br />
PL-1<br />
(Optional)<br />
5.0<br />
✓<br />
✓<br />
100 Watt Lamp, ANSI Code H38<br />
120<br />
208<br />
240<br />
277<br />
74P2503-011P<br />
74P2513-011P<br />
74P2523-011P<br />
74P2533-011P<br />
CWA 122<br />
1.1<br />
.7<br />
.6<br />
.5<br />
250<br />
3<br />
2<br />
2<br />
2<br />
12.0<br />
PL-2<br />
(Included)<br />
6.5<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
120 74P2802-011 HX-NPF<br />
2.8 245 7<br />
120<br />
277 74P2832-011 R-NPF 1.4 277 4<br />
7.0<br />
PL-1<br />
(Included)<br />
PL-1<br />
(Included)<br />
5.0<br />
✓<br />
✓<br />
✓<br />
✓<br />
✝ Ordering information:<br />
Order catalog number indicated. <strong>Ballasts</strong> rated 100 watts and above include pre-assembled spring clip and support chain kit.<br />
For ballasts rated less than 100 watts, if spring clip and support chain kit is desired, order separately.<br />
• For CWA circuits, figure is operating current. For HX and R circuits, figure is highest of starting, operating or open circuit current.<br />
PHOTO<br />
CONTROL<br />
PHOTO*<br />
CONTROL<br />
BLACK<br />
GREEN<br />
GREEN<br />
GREEN<br />
GREEN<br />
TO<br />
FIXTURE<br />
FRAME<br />
TO<br />
FIXTURE<br />
BLACK<br />
FRAME<br />
RED<br />
RED<br />
INPUT<br />
VOLTS<br />
BLACK<br />
NPUT<br />
OLTS<br />
LACK<br />
WHITE<br />
WHITE<br />
BLUE<br />
COM<br />
WHITE<br />
OM<br />
HITE<br />
BLUE<br />
LAMP<br />
e: If Photo Control is not used,<br />
ect Red and Black leads together<br />
LAMP<br />
Postline Wiring Diagram<br />
Note: If Photo<br />
Control is not<br />
used, connect<br />
Red and Black<br />
leads together.<br />
PL-1 and PL-2 - Spring Clip and<br />
Support Chain Kits<br />
Included pre-assembled with all<br />
postline ballasts rated 100 watts<br />
and above. Support chain lowers<br />
ballast 18” down post while 6” or<br />
10” spring clip forces ballast<br />
against post’s inner wall to assure<br />
proper heat dissipation away from<br />
ballast’s internal components.<br />
Also includes factory-connected<br />
ground wire to provide for proper<br />
grounding of ballast case and fixture<br />
housing. Kits include instruction<br />
sheet and may be ordered<br />
separately to retrofit existing<br />
installations.<br />
18” Chain &<br />
Ground Wire<br />
¹₂” NPT - 14 Nipple<br />
Spring Clip:<br />
PL-1 6” for 7.0”<br />
long ballasts<br />
PL-2 10” for 12.0”,<br />
17.6”, 21.0”<br />
long ballasts<br />
2.55” dia.<br />
L<br />
HID • POSTLINE<br />
Postline Wiring Diagram<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-64
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Postline <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
Mercury<br />
Input<br />
Volts<br />
Catalog Number<br />
(P=Thermally<br />
Protected)<br />
✝<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max<br />
•<br />
Input<br />
Current<br />
Nom. Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
(amps)<br />
Length<br />
(in)<br />
Spring Clip<br />
& Support<br />
Chain Kit<br />
Weight<br />
(lbs)<br />
Certifications<br />
175 Watt Lamp, ANSI Code H39<br />
120<br />
208<br />
240<br />
277<br />
74P3003-011P<br />
74P3013-011P<br />
74P3023-011P<br />
74P3033-011P<br />
CWA 215<br />
1.8<br />
1.1<br />
.9<br />
.9<br />
✝ Ordering information:<br />
Order catalog number indicated. <strong>Ballasts</strong> rated 100 watts and above include pre-assembled spring clip and support chain kit.<br />
• For CWA circuits, figure is operating current. For HX and R circuits, figure is highest of starting, operating or open circuit current.<br />
240<br />
5<br />
3<br />
3<br />
2<br />
PL-2<br />
(Included)<br />
175 HPS Watt Lamp, ANSI Code H39<br />
or 150 Watt Lamp, ANSI Code S63, EZ Lux (GE), Unalux (Osram Sylvania), Econolux (Philips), Retrolux (Philips)<br />
120<br />
208<br />
240<br />
277<br />
74P3303-011<br />
74P3313-011<br />
74P3323-011<br />
74P3333-011<br />
HX-NPF<br />
R-NPF<br />
250 Watt Lamp, ANSI Code H37<br />
120<br />
208<br />
240<br />
277<br />
74P3503-011P<br />
74P3513-011P<br />
74P3523-011P<br />
74P3533-011P<br />
210<br />
215<br />
205<br />
205<br />
CWA 300<br />
5.7<br />
2.8<br />
2.7<br />
2.5<br />
2.6<br />
1.5<br />
1.3<br />
1.2<br />
245<br />
245<br />
240<br />
277<br />
250<br />
15<br />
7<br />
7<br />
7<br />
7<br />
4<br />
4<br />
3<br />
12.0<br />
7.0<br />
7.0<br />
21.0<br />
PL-1<br />
(Included)<br />
PL-1<br />
(Included)<br />
PL-2<br />
(Included)<br />
6.5<br />
5.0<br />
5.0<br />
11.0<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
HID • POSTLINE<br />
PHOTO<br />
CONTROL<br />
PHOTO*<br />
CONTROL<br />
BLACK<br />
GREEN<br />
GREEN<br />
GREEN<br />
GREEN<br />
TO<br />
FIXTURE<br />
FRAME<br />
RED<br />
TO<br />
FIXTURE<br />
FRAME<br />
BLACK<br />
RED<br />
INPUT<br />
VOLTS<br />
BLACK<br />
INPUT<br />
VOLTS<br />
BLACK<br />
WHITE<br />
WHITE<br />
BLUE<br />
COM<br />
WHITE<br />
BLUE<br />
COM<br />
WHITE<br />
LAMP<br />
*Note: If Photo Control is not used,<br />
connect Red and Black leads together<br />
LAMP<br />
Postline Wiring Diagram<br />
Note: If Photo<br />
Control is not<br />
used, connect<br />
Red and Black<br />
leads together.<br />
PL-1 and PL-2 - Spring Clip and<br />
Support Chain Kits<br />
Included pre-assembled with all<br />
postline ballasts rated 100 watts<br />
and above. Support chain lowers<br />
ballast 18” down post while<br />
6” or 10” spring clip forces ballast<br />
against post’s inner wall to<br />
assure proper heat dissipation<br />
away from ballast’s internal<br />
components. Also includes factory-connected<br />
ground wire to<br />
provide for proper grounding of<br />
ballast case and fixture housing.<br />
Kits include instruction sheet<br />
and may be ordered separately<br />
to retrofit existing installations.<br />
18” Chain &<br />
Ground Wire<br />
¹₂” NPT - 14 Nipple<br />
Spring Clip:<br />
PL-1 6” for 7.0”<br />
long ballasts<br />
PL-2 10” for 12.0”,<br />
17.6”, 21.0”<br />
long ballasts<br />
L<br />
Postline Wiring Diagram<br />
2.55” dia.<br />
5-65<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Postline <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
HID<br />
Metal Halide<br />
Input<br />
Volts<br />
Catalog Number<br />
(P=Thermally<br />
Protected)<br />
✝<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom. Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
(amps)<br />
Length<br />
(in)<br />
Weight<br />
(lbs)<br />
Spring Clip<br />
& Support<br />
Chain Kit<br />
Max Dist<br />
To Lamp<br />
(ft)<br />
Certifications<br />
50 Watt Lamp, ANSI Code M110<br />
120<br />
74P5103-011<br />
74P5104-011P<br />
HX-NPF<br />
HX-PFC<br />
69<br />
1.8<br />
1.1<br />
260<br />
5<br />
3<br />
12.0<br />
6.0<br />
PL-2<br />
(Optional)<br />
20<br />
✓<br />
✓<br />
✓<br />
✓<br />
✝ Ordering information:<br />
Order catalog number indicated. If spring clip and support chain kit is desired,<br />
order separately.<br />
• For HX circuit, figure is highest of starting, operating or open circuit current.<br />
PHOTO<br />
CONTROL<br />
PHOTO*<br />
CONTROL<br />
BLACK<br />
GREEN<br />
GREEN<br />
GREEN<br />
GREEN<br />
TO<br />
FIXTURE<br />
FRAME<br />
TO<br />
FIXTURE<br />
FRAME<br />
RED<br />
BLACK<br />
RED<br />
INPUT<br />
VOLTS<br />
BLACK<br />
INPUT<br />
VOLTS<br />
BLACK<br />
WHITE<br />
WHITE<br />
BLUE<br />
COM<br />
WHITE<br />
COM<br />
WHITE<br />
BLUE<br />
LAMP<br />
*Note: If Photo Control is not used,<br />
connect Red and Black leads together<br />
LAMP<br />
Postline Wiring Diagram<br />
Note: If Photo<br />
Control is not<br />
used, connect<br />
Red and Black<br />
leads together.<br />
PL-1 and PL-2 - Spring Clip and<br />
Support Chain Kits<br />
Included pre-assembled with all<br />
postline ballasts rated 100 watts<br />
and above. Support chain lowers<br />
ballast 18” down post while<br />
6” or 10” spring clip forces ballast<br />
against post’s inner wall to<br />
assure proper heat dissipation<br />
away from ballast’s internal<br />
components. Also includes factory-connected<br />
ground wire to<br />
provide for proper grounding of<br />
ballast case and fixture housing.<br />
Kits include instruction sheet<br />
and may be ordered separately<br />
to retrofit existing installations.<br />
18” Chain &<br />
Ground Wire<br />
¹₂” NPT - 14 Nipple<br />
Spring Clip:<br />
PL-1 6” for 7.0”<br />
long ballasts<br />
PL-2 10” for 12.0”,<br />
17.6”, 21.0”<br />
long ballasts<br />
L<br />
HID • POSTLINE<br />
Postline Wiring Diagram<br />
2.55” dia.<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-66
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Postline <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />
High Pressure Sodium<br />
Input<br />
Volts<br />
Catalog Number✝<br />
(P=Thermally<br />
Protected)<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max<br />
•<br />
Input<br />
Current<br />
Nom. Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
(amps)<br />
Length<br />
(in)<br />
Weight<br />
(lbs)<br />
Spring Clip<br />
& Support<br />
Chain Kit<br />
Max Dist<br />
To Lamp<br />
(ft)<br />
Certifications<br />
HID • CORE & COIL<br />
HPS<br />
35 Watt Lamp, ANSI Code S76<br />
74P7702-011 R-NPF<br />
120<br />
74P7703-011P R-HPF<br />
✝ Ordering information:<br />
Order catalog number indicated. <strong>Ballasts</strong> rated 100 watts<br />
and above include pre-assembled spring clip and support<br />
chain kit. For ballasts rated less than 100 watts, if spring<br />
clip and support chain kit is desired, order separately.<br />
* 70 watt High Pressure Sodium ballasts with 208, 240, or<br />
277 Volt inputs will always be supplied with the spring clip<br />
and chain kit.<br />
• For CWA circuits, figure is operating current. For HX and R<br />
circuits, figure is highest of starting, operating or open circuit<br />
current.<br />
PL-1 and PL-2 - Spring Clip and Support Chain Kits<br />
Included pre-assembled with all postline ballasts rated 100<br />
watts and above. Support chain lowers ballast 18” down post<br />
while 6” or 10” spring clip forces ballast against post’s inner wall<br />
to assure proper heat dissipation away from ballast’s internal<br />
components. Also includes factory-connected ground wire to<br />
provide for proper grounding of ballast case and fixture housing.<br />
Kits include instruction sheet and may be ordered separately<br />
to retrofit existing installations.<br />
43<br />
50 Watt Lamp, ANSI Code S68<br />
120 74P7802-011 R-PFC 61<br />
120<br />
1.2<br />
.8<br />
74P7803-011P R-HPF 61 1.3 120 4 12.0 4.8<br />
70 Watt Lamp, ANSI Code S62<br />
120 74P7902-011 R-NPF 84<br />
120<br />
208<br />
240<br />
277<br />
74P7913-011P<br />
74P7923-011P<br />
74P7933-011P<br />
HX-HPF 97<br />
100 Watt Lamp, ANSI Code S54<br />
120<br />
208<br />
240<br />
277<br />
74P8002-011<br />
74P8003-011P<br />
74P8013-011P<br />
74P8023-011P<br />
74P8033-011P<br />
R-NPF<br />
R-HPF<br />
122<br />
HX-HPF 136<br />
120<br />
1.8 120<br />
.9<br />
.8<br />
.7<br />
3.1<br />
2.5<br />
1.1<br />
1.0<br />
.9<br />
150 Watt Lamp, ANSI Code S55 (55-Volt Arc Tube)<br />
74P8103-011 R-NPF<br />
4.6<br />
120<br />
178<br />
74P8104-011P R-HPF<br />
3.6<br />
2.2 120<br />
208<br />
240<br />
277<br />
120<br />
208<br />
240<br />
277<br />
120<br />
3<br />
2<br />
3.0<br />
3.5<br />
5 7.0 3.5<br />
74P7903-011P R-PFC 84 1.6 120 4 12.0 5.0<br />
18” Chain &<br />
Ground Wire<br />
¹₂” NPT -<br />
14 Nipple<br />
Spring Clip:<br />
PL-1<br />
6” for 7.0”<br />
long ballasts<br />
PL-2<br />
10” for 12.0”,<br />
17.6”, 21.0”<br />
long ballasts<br />
2.55” dia.<br />
6 7.0 3.5<br />
2<br />
2<br />
2<br />
8<br />
7<br />
3<br />
3<br />
3<br />
12<br />
9<br />
7.0<br />
17.6<br />
12.0<br />
17.6<br />
21.0<br />
12.0<br />
17.6<br />
8.5<br />
5.5<br />
7.3<br />
12.7<br />
6.0<br />
7.8<br />
L<br />
PL-1<br />
(Optional)<br />
PL-1<br />
(Optional)<br />
PL-2<br />
(Optional)<br />
PL-1<br />
(Optional)<br />
PL-2<br />
(Optional)<br />
PL-2*<br />
(Included)<br />
PL-2<br />
(Included)<br />
PL-2<br />
(Included)<br />
PL-2<br />
(Included)<br />
PHOTO<br />
CONTROL<br />
PHOTO*<br />
CONTROL<br />
BLACK<br />
GREEN<br />
GREEN<br />
GREEN<br />
GREEN<br />
TO<br />
FIXTURE<br />
FRAME<br />
TO<br />
FIXTURE<br />
FRAME<br />
RED<br />
BLACK<br />
RED<br />
INPUT<br />
VOLTS<br />
BLACK<br />
10<br />
10<br />
10<br />
10<br />
10<br />
10<br />
5<br />
5<br />
5<br />
INPUT<br />
VOLTS<br />
BLACK<br />
WHITE<br />
WHITE<br />
BLUE<br />
COM<br />
WHITE<br />
BLUE<br />
COM<br />
WHITE<br />
Postline Wiring Diagram<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
LAMP<br />
*Note: If Photo Control is not used,<br />
connect Red and Black leads together<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
LAMP<br />
Postline Wiring Diagram<br />
Note: If Photo<br />
Control is not<br />
used, connect<br />
Red and Black<br />
leads together.<br />
5-67<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Indoor Enclosed <strong>Ballasts</strong><br />
HID<br />
Mercury/HPS<br />
High Pressure Sodium<br />
(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Circuit<br />
Type<br />
Maximum<br />
Ambient<br />
Temp.<br />
( )<br />
Watts<br />
Input<br />
Max<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
(amps)<br />
Weight<br />
(Ibs)<br />
200 Watt Lamp, ANSI Code S66<br />
CWA<br />
480 78E8940-001<br />
240 0.6 185 3 IE-1 PC-724 31<br />
(50 C)<br />
•<br />
Wiring<br />
Dia.<br />
Case<br />
Style<br />
Certification<br />
✓<br />
LAMP<br />
LAMP<br />
TO LINE<br />
COM<br />
TOP<br />
Fig. IE-1<br />
LINE V<br />
INSULATE UNUSED<br />
LAMP LEADS<br />
INDIVIDUALLY FOR 600V FOR 600V<br />
COM<br />
250 Watt Lamp, ANSI Code S50<br />
120/208/<br />
CWA<br />
78E8291-001<br />
295<br />
240/277<br />
(50 C)<br />
400 Watt Lamp, ANSI Code S51<br />
120/208/<br />
78E8493-001 CWA<br />
240/277<br />
464<br />
(40 C)<br />
480 78E8443-001<br />
1000 Watt Lamp, ANSI Code S52<br />
120/208/<br />
240/277<br />
480<br />
78E8793-001<br />
78E8743-001<br />
CWA<br />
(Protected★)<br />
(40 C)<br />
1100<br />
2.5/1.5/<br />
1.3/1.1<br />
3.8/2.2/<br />
1.9/1.7<br />
1.0<br />
9.5/5.5/<br />
4.8/4.2<br />
2.3<br />
187<br />
190<br />
435<br />
7/4/<br />
4/3<br />
10/8/<br />
5/5<br />
3<br />
25/15/<br />
10/10<br />
6<br />
IE-2<br />
IE-2<br />
IE-1<br />
IE-2<br />
IE-1<br />
PC-724 34<br />
PC-724 38<br />
PC-746 60<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
LAMP<br />
LAMP<br />
COM<br />
TOP<br />
Fig. IE-2<br />
INSULATE UNUSED<br />
INSULATE LAMP UNUSED LEAD<br />
LAMP FOR LEADS 600V<br />
INDIVIDUALLY FOR 600V<br />
COM<br />
COM<br />
120 V<br />
208 V<br />
240 V<br />
277 V<br />
Note: <strong>Ballasts</strong> must be mounted at least 12” apart. All indoor enclosed high pressure<br />
sodium and pulse-start metal halide lamp ballasts are furnished with an <strong>Advance</strong> long<br />
life ignitor built into the ballast can. Maximum lamp-to-ballast distance is 50 ft.<br />
(Except 1000 watt ballasts which are 75 ft). For ballasts not requiring ignitors,<br />
see page 5-50 for remote mounting considerations.<br />
• For CWA circuits, figure is operating current.<br />
★ Equipped with an auto-reset thermal protector to prevent ignitor from overheating in the<br />
event of lamp failure.<br />
Please see Metal Halide <strong>Section</strong> for Indoor Enclosed <strong>Ballasts</strong><br />
78E<br />
R ENCLOSED<br />
MENSIONS<br />
3 /8" Oval Slots<br />
F<br />
Top view<br />
3 double<br />
7 /8" and 1 1 /8"<br />
knockouts<br />
HID<br />
INDOOR ENCLOSED<br />
A B C D<br />
G<br />
E<br />
DIMENSIONS<br />
Case<br />
Style<br />
A B C D E<br />
PC-723 11³₈ 12 12³₄ 13³₄ 3⁵₁₆<br />
PC-724 12¹₁₆ 12¹¹₁₆ 13⁷₁₆ 14⁷₁₆ 3⁵₁₆<br />
PC-746 17³₈ 18 18³₄ 19³₄ 3⁵₁₆<br />
F<br />
6⁹₁₆<br />
7¹¹₁₆<br />
7¹¹₁₆<br />
G<br />
4³₄<br />
5³₄<br />
5³₄<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-68
HIGH INTENSITY DISCHARGE BALLASTS<br />
Outdoor Weatherproof <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
HID<br />
Mercury<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max<br />
•<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
(amps)<br />
Wiring<br />
Dia.<br />
Height<br />
(in)<br />
Weight<br />
(Ibs)<br />
Certification<br />
100 Watt Lamp, ANSI Code H38 or H44<br />
120/208/<br />
240/277<br />
79W2591-001 CWA 125<br />
1.1/.6/<br />
.6/.5<br />
250<br />
3/2/<br />
2/2<br />
OW-2<br />
6.6 10<br />
✓<br />
✓<br />
250 Watt Lamp, ANSI Code H37<br />
120/208/<br />
240/277<br />
480<br />
79W3592-001<br />
79W3542-001<br />
CWA 285<br />
2.5/1.5/<br />
1.3/1.1<br />
.7<br />
250<br />
8/5/<br />
5/3<br />
2<br />
OW-2<br />
OW-1<br />
6.6 13<br />
✓<br />
✓<br />
✓<br />
✓<br />
• For CWA circuits, figure is operating current.<br />
LAMP COM COM LINE V<br />
TO LINE<br />
LAMP<br />
COM<br />
120 LINE V 208 LINE V 240 LINE V 277 LINE V<br />
Fig. OW-1<br />
TO LINE<br />
Fig. OW-2<br />
HID • OUTDOOR<br />
WEATHERPROOF<br />
SH-1 (without a hose clamp)<br />
Not included with ballast. Available at<br />
no charge when ordered with ballast.<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-69
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
Outdoor Weatherproof <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –20°F or –30°C)<br />
Metal Halide<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
(amps)<br />
Wiring<br />
Dia.<br />
Height<br />
(in)<br />
Weight<br />
(Ibs)<br />
Certification<br />
175/150 Watt Lamp, ANSI Code M57/M107 or H39<br />
120/208/<br />
240/277<br />
79W5590-001 CWA 210<br />
250 Watt Lamp, ANSI Code M58 or H37<br />
120/208/<br />
240/277<br />
79W5790-001 CWA 285<br />
1.8/1.1/<br />
.9/.8<br />
2.5/1.5/<br />
1.3/1.1<br />
305<br />
310<br />
5/3/<br />
3/2<br />
8/5/<br />
5/3<br />
OW-2<br />
OW-2<br />
6.6 15<br />
8.6 18<br />
400 Watt Lamp, ANSI Code M59 or H33<br />
120/208/<br />
4.0/2.3/<br />
10/7/<br />
79W6091-001<br />
458<br />
OW-2<br />
240/277<br />
CWA<br />
2.0/1.8 300 5/5<br />
8.6 21 ✓ ✓<br />
480 79W6041-001<br />
462 1.0<br />
4 OW-1<br />
✓ ✓<br />
Two 400 Watt Lamps, ANSI Code M59 or H33<br />
120/240 79W6351-001<br />
CWA<br />
8.4/4.2<br />
25/15<br />
✓ ✓<br />
890<br />
330 OW-4 13.8 43<br />
480 79W6341-001<br />
(ILO)<br />
2.1 7 ✓ ✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
LAMP COM COM LINE V<br />
TO LINE<br />
Fig. OW-1<br />
LAMP COM 120 LINE V 208 LINE V 240 LINE V 277 LINE V<br />
TO LINE<br />
Fig. OW-2<br />
1000 Watt Lamp, ANSI Code M47 or H36<br />
120/208/<br />
240/277<br />
480<br />
79W6592-001<br />
79W6542-001<br />
CWA 1080<br />
9.0/5.2/<br />
4.5/3.9<br />
2.3<br />
430<br />
20/15/<br />
10/10<br />
6<br />
OW-2<br />
OW-1<br />
11.3 33<br />
✓<br />
✓<br />
✓<br />
✓<br />
NSULATE UNUSED<br />
ALTERNATE LAMP<br />
EADS INDIVIDUALLY<br />
FOR 600V<br />
HID • OUTDOOR<br />
WEATHERPROOF<br />
1500 Watt Lamp, ANSI Code M48<br />
120/208/<br />
79W6792-001<br />
1605<br />
240/277<br />
CWA<br />
480 79W6742-001<br />
1625<br />
• For CWA circuits, figure is operating current.<br />
13.5/7.8/<br />
6.8/5.9<br />
3.4<br />
450<br />
30/25/<br />
20/15<br />
10<br />
OW-2<br />
OW-1<br />
13.8<br />
41<br />
40<br />
✓<br />
✓<br />
✓<br />
✓<br />
LAMP 1 COM LAMP 2 COM LINE V LINE V<br />
TO LINE<br />
Fig. OW-4<br />
SH-1 (without a hose clamp)<br />
Not included with ballast. Available at<br />
no charge when ordered with ballast.<br />
5-70<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
Outdoor Weatherproof <strong>Ballasts</strong><br />
(60 Hz., Minimum Starting Temperature –40°F or –40°C)<br />
HID<br />
High Pressure Sodium<br />
Input<br />
Volts<br />
Catalog<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
(amps)<br />
Wiring<br />
Dia.<br />
Height<br />
(in)<br />
Weight<br />
(Ibs)<br />
Certification<br />
150 Watt Lamp, ANSI Code S55 (55-Volt Arc Tube)<br />
120/208/<br />
240/277<br />
79W8192-001 HX-HPF 188<br />
250 Watt Lamp, ANSI Code S50<br />
120/208/<br />
79W8291-001<br />
240/277<br />
CWA 310<br />
480 79W8241-001<br />
2.8/1.6/<br />
1.4/1.3<br />
2.5/1.5/<br />
1.3/1.1<br />
0.7<br />
All weatherproof high pressure sodium lamp ballasts are furnished with an <strong>Advance</strong> long life ignitor built<br />
into the ballast can. Maximum lamp-to-ballast distance is 50 ft. (except 79W8192 - distance is 35 ft and<br />
1000 watt ballasts which are 75 ft.)<br />
• For CWA circuits, figure is operating current. For HX circuits, figure is highest of starting, operating or open<br />
circuit current.<br />
★ Equipped with an auto-reset thermal protector to prevent ignitor from overheating in the event of lamp failure.<br />
120<br />
10/5/<br />
5/4<br />
OW-2 8.6 12 ✓ ✓<br />
310 Watt Lamp, ANSI Code S67<br />
240/480 79W9597-001 CWA 365 1.7/.9 175 5/3 OW-2 11.3 17<br />
400 Watt Lamp, ANSI Code S51<br />
120/208/<br />
240/277<br />
480<br />
79W8493-001<br />
79W8443-001<br />
CWA 464<br />
1000 Watt Lamp, ANSI Code S52<br />
120/208/<br />
240//277<br />
480<br />
79W8793-001<br />
79W8743-001<br />
CWA<br />
(Protected)<br />
★<br />
1100<br />
3.8/2.2<br />
1.9/1.7<br />
1.0<br />
9.5/5.5/<br />
4.8/4.2<br />
2.3<br />
187<br />
190<br />
435<br />
7/4/<br />
4/3<br />
2<br />
10/8/<br />
5/5<br />
3<br />
25/15/<br />
10/10<br />
6<br />
OW-2<br />
OW-1<br />
OW-2<br />
OW-1<br />
OW-2<br />
OW-1<br />
11.3<br />
14<br />
17<br />
11.3 20<br />
13.8 34<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
✓<br />
LAMP COM COM LINE V<br />
TO LINE<br />
Fig. OW-1<br />
LAMP COM 120 LINE V 208 LINE V 240 LINE V 277 LINE V<br />
TO LINE<br />
Fig. OW-2<br />
HID • OUTDOOR<br />
WEATHERPROOF<br />
SH-1 (without a hose clamp)<br />
Not included with ballast. Available at<br />
no charge when ordered with ballast.<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
5-71
SPECIALTY PRODUCTS<br />
Contents<br />
Specialty Fluorescent and HID <strong>Ballasts</strong> and LED Drivers<br />
Residential Lighting ............................................................................6-4<br />
<strong>Ballasts</strong> that meet FCC Consumer limits and can be used in<br />
Energy Star Fixtures<br />
UV Disinfection....................................................................................6-5<br />
Ballast for Germicidal/UV lamps<br />
Refrigeration, Tanning and Display Lighting......................................6-6<br />
<strong>Ballasts</strong> for T8 and T12/HO lamps<br />
Ballast Dimensions and Wiring Diagrams..................................6-7 to 6-8<br />
International <strong>Ballasts</strong> (Locations other than North America)<br />
High Frequency <strong>Electronic</strong> Fluorescent <strong>Ballasts</strong><br />
General Information ........................................................................6-9<br />
<strong>Ballasts</strong> for Rapid Start, HO & CFL Lamps .......................6-10 to 6-12<br />
Electromagnetic Fluorescent <strong>Ballasts</strong><br />
General Information ......................................................................6-13<br />
<strong>Ballasts</strong> for Rapid Start, HO, Slimline & Preheat Lamps ..6-14 to 6-17<br />
Electromagnetic HID <strong>Ballasts</strong><br />
General Information ......................................................................6-18<br />
50 Hz Core & Coil for <strong>Ballasts</strong>..........................................6-19 to 6-21<br />
Mercury - Metal Halide - High Pressure Sodium lamps<br />
60 Hz Core & Coil (Southern Japan).............................................6-22<br />
Mercury - Metal Halide<br />
50 Hz Core & Coil (Northern Japan) .............................................6-23<br />
Mercury - Metal Halide<br />
LED <strong>Electronic</strong> Drivers<br />
Xitanium TM LED Drivers for Europe ......................................................6-24<br />
Corporate Offices<br />
(800) 322-2086<br />
Customer Support/Technical Service<br />
(800) 372-3331 • (+) 1 847 390-5000 (Specialty)<br />
SPECIALTY<br />
Visit our web site at www.advancetransformer.com<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 6-1
RESIDENTIAL BALLASTS<br />
Fluorescent <strong>Ballasts</strong> - <strong>Electronic</strong> - AmbiStar <br />
<strong>Electronic</strong> <strong>Ballasts</strong> for 4-pin Compact Fluorescent and T5, T8 or T12 Linear Lamps<br />
<strong>Advance</strong>'s family of electronic ballasts specifically designed for popular fluorescent applications<br />
in homes and other non-commercial environments brings all of the energy-efficient benefits of<br />
fluorescent lighting to residential and hospitality applications. FCC Class B EMI compliant and<br />
available for T5 linear (8-14W), T8 linear (17-32W), T12 linear (34W-40W) and 4-pin CFL lamps.<br />
<strong>Advance</strong>'s AmbiStar ballasts are compact and lightweight, provide quick starting and save users<br />
significant energy costs relative to alternative lighting sources.<br />
Features<br />
Less than 1.0 second starting<br />
<strong>Electronic</strong> design<br />
Class B FCC EMI Rating meets Energy Star<br />
and consumer EMI requirements<br />
End-of-Lamp life protection for T5 lamps<br />
and smaller<br />
Benefits<br />
Provides flicker-free starting<br />
Increased energy savings over incandescent and<br />
fluorescent magnetic with no audible noise<br />
Insures approval in residential applications<br />
Safely removes power to the lamp(s)<br />
SPECIALTY<br />
RESIDENTIAL<br />
6-2<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
UV DISINFECTION BALLASTS<br />
<strong>Electronic</strong> <strong>Ballasts</strong> for High Output (HO) Germicidal<br />
Ultraviolet (UV) Lamps<br />
In support of the growing popularity of High Output (HO) germicidal UV-C lamps--<br />
which have been proven effective at improving indoor air quality in low temperature<br />
environments such as HVAC systems--<strong>Advance</strong>'s PureVOLT electronic UV ballast is<br />
specially designed to operate a variety of 800mA HO UV lamps.<br />
PureVOLT is ideal in such applications as hospitals, food processing facilities,<br />
schools, office buildings, recreational facilities, and residences.<br />
Features<br />
Microprocessor-controlled design<br />
IntelliVolt® multiple-voltage technology<br />
enables operation at any input voltage from<br />
120 to 277 volts, 50/60Hz<br />
Benefits<br />
Enables one UV ballast to operate multiple lamps<br />
Enhances accuracy of ordering and reduces SKU<br />
requirements<br />
End-of-Lamp-Life Protection<br />
Safely removes power to the lamp(s)<br />
Auto-restart<br />
Programmed-start technology<br />
Eliminates the need to reset power mains after lamp<br />
replacement<br />
Provides extended lamp life in frequent switching<br />
applications<br />
SPECIALTY<br />
UV DISINFECTION<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 6-3
T4, T5, T8 & T12<br />
RESIDENTIAL LIGHTING<br />
For 7 - 42W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
UL Listed Lamp Types<br />
Page No.<br />
CFL Lamps<br />
1 or 2 120<br />
1 or 2 120<br />
1 or 2 120<br />
1 or 2 120<br />
1 or 2 120<br />
QS<br />
QS<br />
QS<br />
PS<br />
AmbiStar<br />
AmbiStar<br />
AmbiStar<br />
AmbiStar<br />
1 120 IS AmbiStar<br />
1 120<br />
1 or 2 120<br />
Linear T8 Lamps<br />
IS<br />
IS<br />
AmbiStar<br />
AmbiStar<br />
1 or 2 120 iS AmbiStar<br />
3 or 4 120 IS AmbiStar<br />
Linear T12 Lamps<br />
PS<br />
CFL & Linear T5 Lamps<br />
AmbiStar<br />
RCF-2S13-H1-LD-QS<br />
RCF-2S13-M1-BS-QS<br />
RCF-2S13-M1-LS-QS<br />
RCF-2S18-H1-LD-QS<br />
RCF-2S18-M1-BS-QS<br />
RCF-2S18-M1-LS-QS<br />
RCF-2S26-H1-LD-QS<br />
RCF-2S26-M1-BS-QS<br />
RCF-2S26-M1-LS-QS<br />
REB-2S18-M1-BS-DIM<br />
REB-2S18-M1-LS-DIM<br />
REB-2S26-M1-BS-DIM<br />
REB-2S26-M1-LS-DIM<br />
RMB-1P26-S2<br />
RMB-1P13-L2<br />
RMB-1P13-S1<br />
RMB-1P13-S2-H<br />
RMB-2P13-L2<br />
RMB-2P13-S2<br />
RMB-2P13-S2-H<br />
REB-2P32-SC<br />
REB-4P32-SC<br />
(1) or (2) 13W CFL 1-27, 1-29<br />
(1) or (2) 18W CFL 1-27, 1-30<br />
(1) or (2) 26W CFL<br />
(1) 32W, 42W CFL<br />
1-28, 1-31, 1-32<br />
(1) or (2) 18W CFL 2-5<br />
(1) or (2) 26W CFL<br />
(1) 32W, 42W CFL<br />
(1) 26W CFL<br />
(1) 18W, 24W Long Twin Tube or (1) 22W Circline<br />
(1) 7W, 9W, 13W CFL<br />
(1) F8T5, F13T5, F14T5 Linear<br />
(1) 18W or (2) 7W, 9W, 13W CFL<br />
(1) F8T5 & (1) F13T5 or (2) F8T5, F13T5, F14T5<br />
Linear<br />
(1) or (2) F17T8, F25T8, F32T8 Linear<br />
(3) or (4) F17T8, F25T8, F32T8 Linear<br />
2-5<br />
1-28, 1-31, 1-34<br />
1-42, 1-67<br />
1-26, 1-27, 1-29,<br />
1-40, 1-41<br />
1-26, 1-27, 1-29,<br />
1-30, 1-40, 1-41<br />
1-44, 1-45, 1-48,<br />
1-49, 1-58, 1-59<br />
1-46, 1-47, 1-50,<br />
1-51, 1-60, 1-61<br />
1 120 RS Standard RELB-2S40-SC<br />
(2) F34T12, F40T12 Linear<br />
1-67<br />
SPECIALTY<br />
RESIDENTIAL<br />
Above ballasts comply with the requirements of the Federal Communications Commission (FCC) rules and requlations Title 47 CFR Part 18,<br />
Consumer (Class B) for EMI/RFI (conducted and radiated).<br />
Above ballasts meet the ballast-controlled performance requirements in the ENERGY STAR Program Requirements for Residential Lite Fixtures<br />
The most current list of ballasts can be found at www.advance transformer.com/resources/literature in the file "ENERGY STAR Ballast Matrix"<br />
6-4<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
UV DISINFECTION<br />
For 15 - 145W Lamps<br />
T5, T8 & T5/HO<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Lamp<br />
Current<br />
(mAmps)<br />
Max.<br />
THD<br />
%<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
PL-L18W/TUV (18W)<br />
1 120 - 277 PS PureVOLT IUV-2S18-H1-LD 30 290 10 0.26 - 0.11 0/-18 Size 1 160<br />
2 120 - 277 PS PureVOLT IUV-2S18-H1-LD 55 280 10 0.47 - 0.20 0/-18 Size 1 159<br />
PL-L36W/TUV (36W)<br />
1 120 - 277 PS PureVOLT IUV-2S36-M2-LD 51 330 10 0.44 - 0.19 0/-18 Size 2 160<br />
2 120 - 277 PS PureVOLT IUV-2S36-M2-LD 90 285 10 0.78 - 0.33 0/-18 Size 2 159<br />
PL-L35WHO/TUV (35W)<br />
1 120 - 277 PS PureVOLT<br />
IUV-2S60-M4-BS<br />
IUV-2S60-M4-LD<br />
40 850 10 0.35 - 0.15 0/-18 Size 4 160<br />
2 120 - 277 PS PureVOLT<br />
IUV-2S60-M4-BS<br />
IUV-2S60-M4-LD<br />
78 850 10 0.68 - 0.29 0/-18 Size 4 159<br />
PL-L60WHO/TUV (60W)<br />
1 120 - 277 PS PureVOLT<br />
IUV-2S60-M4-BS<br />
IUV-2S60-M4-LD<br />
70 850 10 0.60 - 0.26 0/-18 Size 4 160<br />
2 120 - 277 PS PureVOLT<br />
IUV-2S60-M4-BS<br />
IUV-2S60-M4-LD<br />
138 850 10 1.20 - 0.52 0/-18 Size 4 159<br />
PL-L95WHO/TUV (95W)<br />
1 120 - 277 PS PureVOLT<br />
IUV-2S60-M4-BS<br />
IUV-2S60-M4-LD<br />
100 800 10 0.87 - 0.37 0/-18 Size 4 160<br />
G15T8 (15W)<br />
1 120 IS Standard REL-2P30G<br />
20 290 30 0.17 0/-18 A *64<br />
2 120 IS Standard REL-2P30G<br />
26 220 20 0.22 0/-18 A 64<br />
G30T8 (30W)<br />
1 120 IS Standard REL-2P30G<br />
30 260 20 0.25 0/-18 A *64<br />
2 120 IS Standard REL-2P30G<br />
45 470 20 0.38 0/-18 A 64<br />
G64T5 (75W)<br />
2 120 IS Standard REL-2P64-IS<br />
179 500 20 1.65 0/-18 C 64<br />
SPECIALTY<br />
UV DISINFECTION<br />
TUV 36T5/HO (75W)<br />
1 120 - 277 PS PureVOLT<br />
IUV-2S60-M4-BS<br />
IUV-2S60-M4-LD<br />
80 800 10 0.69 - 0.30 0/-18 Size 4 160<br />
2 120 - 277 PS PureVOLT<br />
IUV-2S60-M4-BS<br />
IUV-2S60-M4-LD<br />
155 800 10 1.30 - 0.56 0/-18 Size 4 159<br />
TUV 64T5/HO (145W)<br />
1 120 - 277 PS PureVOLT<br />
IUV-2S60-M4-BS<br />
IUV-2S60-M4-LD<br />
155 800 10 1.30 - 0.56 0/-18 Size 4 160<br />
See page 6-7 for Ballast Dimensions<br />
See page 6-8 for Wiring Diagrams<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
6-5
T8 & T12/HO<br />
REFRIGERATION, TANNING AND DISPLAY<br />
For 13 - 168W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
REFRIGERATION<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
F58T8 (58W)<br />
1 120 - 277 PS Centium<br />
ICN-2S54<br />
ICN-2S54-90C<br />
58 1.00 10 0.49 - 0.22 -20/-18 D 73<br />
2 120 - 277 PS Centium<br />
ICN-2S54<br />
ICN-2S54-90C<br />
116 1.00 10 0.97 - 0.42 -20/-18 D 74<br />
3 120 - 277 PS Centium<br />
ICN-4S54-90C-2LS<br />
D<br />
171 1.00 10 1.43 - 0.62 -20/-18<br />
ICN-4S54-90C-2LS-G<br />
G<br />
*75<br />
4 120 - 277 PS Centium<br />
ICN-4S54-90C-2LS<br />
D<br />
225 1.00 10 1.88 - 0.81 -20/-18<br />
ICN-4S54-90C-2LS-G<br />
G<br />
75<br />
F70T8 (70W)<br />
1 120 - 277 PS Centium ICN-1S80<br />
73 0.77 10 0.62 - 0.26 -20/-18 D 73<br />
TANNING<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
F73T12/HO (1000mA) 100W<br />
2 120 RS Magnetic RS-2S100-TP 1 226 1.12 15 2.00 -20/-18 R-9 21<br />
F72T12/VHO (1500mA) 168W<br />
2 120 RS Magnetic RS-2S200-TP<br />
270 0.89 20 2.51 -20/-18 R-11 21<br />
SPECIALTY<br />
REFRIGERATION,<br />
TANNING, DISPALY<br />
1 RS-2S100-TP is only UL approve<br />
DISPLAY<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
F15T8/PLUS, F15T8/XL, FO13T8/XP<br />
Catalog Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
2 120 IS Standard REL-2P32-SC<br />
28 0.95 30 0.24 0/-18 B 64<br />
Dim.<br />
Wiring<br />
Dia.<br />
3 120 IS Standard REL-3P32-SC<br />
40 0.95 20 0.34 0/-18 B 65<br />
4 120 IS Standard REL-4P32-SC<br />
50 0.95 20 0.43 0/-18 B 66<br />
See page 6-7 for Ballast Dimensions<br />
See page 6-8 for Wiring Diagrams<br />
6-6<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
BALLAST DIMENSIONS<br />
Size 12.40"<br />
Size 2<br />
3.00"<br />
Size 4<br />
0.98"<br />
1.29"<br />
1.29"<br />
7.50"<br />
7.00"<br />
7.00"<br />
7.50"<br />
2.00"<br />
1.29"<br />
4.20"<br />
4.60"<br />
4.20"<br />
4.60"<br />
-LD<br />
-LD<br />
3.00"<br />
3.00"<br />
1.18"<br />
8.90"<br />
9.5"<br />
Fig. B<br />
Fig. A<br />
1.7"<br />
1 25 /32”<br />
Fig. D<br />
2 7 /8”<br />
11 3 /4”<br />
11 9 /64”<br />
Slimline<br />
Fig. C<br />
and HO<br />
H<br />
SPECIALTY<br />
1.18"<br />
16.34"<br />
1.70"<br />
16.70"<br />
Fig. G<br />
W<br />
M<br />
L<br />
Case “R”<br />
DIMENSIONS<br />
Designation<br />
Length (L)<br />
(inches)<br />
Width (W)<br />
(inches)<br />
Height (H)<br />
(inches)<br />
Mounting (M)<br />
(inches)<br />
R-9 11³₄ 3³₁₆ 2⁵₈ 11⁹₆₄<br />
R-11 14³₈ 3³₁₆ 2⁵₈ 13³₄<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 6-7
WIRING DIAGRAMS<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
BLUE<br />
BLUE<br />
LAMP<br />
LINE<br />
LAMP<br />
Diag. 64<br />
* For Single Lamp Operation, insulate unused<br />
Diag. 159<br />
blue lead for 600 volts<br />
Diag. 160<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
BLUE<br />
BLUE<br />
WHITE<br />
BLACK<br />
RED<br />
BALLAST<br />
BLUE<br />
BLUE<br />
BLUE<br />
LAMP<br />
LAMP<br />
LINE<br />
LINE<br />
LAMP<br />
LAMP<br />
LAMP<br />
Diag. 64<br />
Diag. 65<br />
Diag. 21<br />
* For Single Lamp Operation, insulate unused<br />
blue lead for 600 volts<br />
* For Two Lamp Operation, insulate unused<br />
blue lead for 600 volts<br />
WHITE<br />
BLACK<br />
YELLOW<br />
YELLOW<br />
BALLAST<br />
BLUE<br />
BLUE<br />
RED<br />
RED<br />
LAMP<br />
LAMP<br />
LINE<br />
LAMP<br />
LAMP<br />
Diag. 66<br />
For 1 lamp operation, do not use yellow leads<br />
* For Three Lamp Operation,<br />
insulate unusedblue lead for 600 volts<br />
Diag. 73<br />
SPECIALTY<br />
Diag. 75<br />
Diag. 74<br />
* For 3-lamp operation connect lamps<br />
between RED and BLUE, BROWN and<br />
BLUE/WHT, YELLOW and BLUE/WHT<br />
6-8<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
INTERNATIONAL HIGH FREQUENCY<br />
ELECTRONIC FLUORESCENT BALLASTS<br />
The following Philips labeled electronic ballasts are available for PLL, T5, T5/HO<br />
and TLD lamps at 220-240 volts (50 or 60 Hertz).<br />
HF-PERFORMER BALLASTS<br />
The HF-Performer electronic ballast is a premium performance<br />
ballast designed specifically for IEC-Specification linear and long<br />
twin tube fluorescent lamps.<br />
Features Include:<br />
• Programmed Rapid Start design optimizes lamp life under all<br />
starting scenarios<br />
• Integrated Circuit-based control technology monitors lamp and<br />
ballast conditions to ensure optimum lighting system performance<br />
• Reduced inrush current; Poke-in WAGO lead connectors<br />
• Designed to meet major European national safety and performance<br />
standards<br />
HF-Performer Ballast Specifications:<br />
1. Ballast shall operate from a nominal line voltage of 220 thru 240<br />
volts, 50/60 Hz. Ballast shall maintain constant wattage output<br />
throughout the operating voltage range<br />
2. Ballast shall be Programmed Start<br />
3. Ballast Power Factor shall be >96%<br />
4. Ballast Total Harmonic Distortion (THD) shall be 15%<br />
5. Ballast shall start the lamp at a min. temperature of 0°F (-15°C)<br />
6. Ballast shall be sound rated A<br />
7. Ballast shall contain no PCB’s<br />
8. Ballast shall carry a 2 year warranty when its case temperature<br />
does not exceed 60°C<br />
9. Complies with safety regulation EN6137-2-3<br />
10. Complies with performance regulation EN60929<br />
11. Complies with EN 55015 for EMI<br />
12. Complies with EU directive 2002/95/EC (RoHS)<br />
13. Approvals: CE<br />
HF-BASIC BALLASTS<br />
The HF-Basic electronic ballast is a standard performance ballast<br />
designed specifically for IEC-Specification TLD fluorescent lamps.<br />
Features Include:<br />
• Instant start design provides greatest operating efficiencies<br />
• Designed to meet major European national safety and performance<br />
standards<br />
• Poke-in WAGO lead connectors<br />
HF-Basic Ballast Specifications:<br />
1. Ballast shall operate from a nominal line voltage of 220 thru 240<br />
volts, 50/60 Hz. Ballast shall maintain constant wattage output<br />
throughout the operating voltage range<br />
2. Ballast shall be Instant Start<br />
3. Ballast Power Factor shall be >96%<br />
4. Ballast Total Harmonic Distortion THD shall be 20%<br />
5. Ballast shall start the lamp at a min. temperature of 0°F (-15°C)<br />
6. Ballast shall be sound rated A<br />
7. Ballast shall contain no PCB’s<br />
8. Ballast shall carry a 2 year warranty when its case temperature<br />
does not exceed 60°C<br />
9. Complies with EN6137-2-3 safety regulation<br />
10. Complies with EN60929 performance regulation<br />
11. Complies with EN 55015 for EMI<br />
12. Complies with EU directive 2002/95/EC (RoHS)<br />
13. Approvals: CE<br />
INTELLIVOLT BALLASTS<br />
<strong>Advance</strong> offers many ballast featuring IntelliVolt input capability. These ballasts will operate on input voltages from 120 through 277 volts<br />
(50 or 60 Hertz). They are designed for ANSI-Specification linear and compact fluorescent lamps, but are only UL and CSA approved.<br />
The fixture or equipment manufacturer must obtain other local approvals, like CE, in order to use these ballasts in locations other than<br />
North America. See <strong>Section</strong> 1 of this <strong>Atlas</strong>, for available ballasts.<br />
INTERNATIONAL<br />
ELECTRONIC<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 6-9
PLL<br />
INTERNATIONAL ELECTRONIC<br />
For 36 - 55W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Hz<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog<br />
Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
PLL 36W<br />
1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 136 PLL 37 0.95 10 0.16 0/-18 A1 3<br />
2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 236 PLL 70 0.95 10 0.30 0/-18 A2 4<br />
PLL 40W<br />
1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 140 PLL 44 0.95 10 0.19 0/-18 A1 3<br />
2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 240 PLL 84 0.95 10 0.36 0/-18 A2 4<br />
PLL 55W<br />
1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 155 PLL 58 0.95 10 0.25 0/-18 A1 3<br />
2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 255 PLL 113 0.95 10 0.49 0/-18 A2 4<br />
DIMENSIONS<br />
Dimensions A1 A2 B1 C1<br />
Fig. A1 11.02” 10.43” 1.18” 1.10”<br />
Fig. A2 11.02” 10.43” 1.18” 1.10”<br />
D1<br />
0.165”<br />
0.165”<br />
INTERNATIONAL<br />
ELECTRONIC<br />
Diag. 3<br />
Fig. A1 & Fig.A2<br />
Diag. 4<br />
6-10<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
INTERNATIONAL ELECTRONIC<br />
For 14 - 54W Lamps<br />
T5 and T5HO<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Hz<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog<br />
Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
F14T5 (14W)<br />
1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 1 14-35 TL5 HE 18 0.95 15 0.08 0/-18 A1 1<br />
2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 2 14-35 TL5 HE 30 0.95 15 0.14 0/-18 A2 2<br />
F21T5 (21W)<br />
1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 1 14-35 TL5 HE 25 0.95 15 0.11 0/-18 A1 1<br />
2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 2 14-35 TL5 HE 46 0.95 15 0.20 0/-18 A2 2<br />
F28T5 (28W)<br />
1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 1 14-35 TL5 HE 33 0.95 15 0.15 0/-18 A1 1<br />
2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 2 14-35 TL5 HE 61 0.95 15 0.27 0/-18 A2 2<br />
F35T5 (35W)<br />
1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 1 14-35 TL5 HE 40 0.95 15 0.18 0/-18 A1 1<br />
2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 2 14-35 TL5 HE 76 0.95 15 0.33 0/-18 A2 2<br />
F24T5/HO (21W)<br />
1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 1 24-39 TL5 HO 28 0.95 15 0.12 0/-18 A3 1<br />
2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 2 24-39 TL5 HO 49 0.95 15 0.22 0/-18 A4 2<br />
F39T5/HO (39W)<br />
1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 1 24-39 TL5 HO 45 0.95 15 0.20 0/-18 A3 1<br />
2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 2 24-39 TL5 HO 86 0.95 15 0.39 0/-18 A4 2<br />
F54T5/HO (54W)<br />
1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 1 54 TL5 HO 61 0.95 15 0.27 0/-18 A3 1<br />
2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 2 54 TL5 HO 120 0.95 15 0.52 0/-18 A4 2<br />
See page 6-12 for Ballast Dimensions<br />
INTERNATIONAL<br />
ELECTRONIC<br />
Diag. 1<br />
Diag. 2<br />
Refer to pages 8-32 to 8-41 for lead lengths and shipping data<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
6-11
TLD<br />
INTERNATIONAL ELECTRONIC<br />
For 18 - 36W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Hz<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog<br />
Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
TLD 18W<br />
1 220 - 240 50 - 60 PS HF-PERFORMER HF-P 118 TLD 19 0.95 15 0.09 0/-18 A1 1<br />
2 220 - 240 50 - 60 PS HF-PERFORMER HF-P 218 TLD 37 0.95 15 0.18 0/-18 A2 2<br />
TLD 36W<br />
1 220 - 240 50 - 60<br />
IS HF-BASIC HF-B 136 TLD 37 0.95 20 0.16<br />
PS HF-PERFORMER HF-P 136 TLD 37 0.95 15 0.16<br />
0/-18<br />
2 220 - 240 50 - 60<br />
IS HF-BASIC HF-B 236 TLD 70 0.95 20 0.32<br />
PS HF-PERFORMER HF-P 236 TLD 70 0.95 15 0.31<br />
0/-18<br />
TLD 58W<br />
1 220 - 240 50 - 60<br />
IS HF-BASIC HF-B 158 TLD 57 0.95 20 0.24<br />
PS HF-PERFORMER HF-P 158 TLD 56 0.95 15 0.24<br />
0/-18<br />
2 220 - 240 50 - 60<br />
IS HF-BASIC HF-B 258 TLD 110 0.95 20 0.48<br />
PS HF-PERFORMER HF-P 258 TLD 107 0.95 15 0.48<br />
0/-18<br />
DIMENSIONS<br />
A1<br />
A2<br />
A1<br />
A2<br />
1<br />
2<br />
1<br />
2<br />
Dimensions A1 A2 B1 C1<br />
Fig. A1 11.02” 10.43” 1.18” 1.10”<br />
Fig. A2 11.02” 10.43” 1.18” 1.10”<br />
Fig. A3 14.17 13.78” 1.18” 0.83”<br />
Fig. A4 14.17 13.78” 1.18” 0.83”<br />
D1<br />
0.165”<br />
0.165”<br />
0.165”<br />
0.165”<br />
Diag. 1<br />
Diag. 2<br />
INTERNATIONAL<br />
ELECTRONIC<br />
Fig. A1 & Fig.A2<br />
Fig. A3 & Fig.A4<br />
6-12<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
INTERNATIONAL ELECTROMAGNETIC FLUORESCENT BALLASTS<br />
ADVANCE offers an extended range of electromagnetic fluorescent ballasts to<br />
operate T8, T10, T12 and compact fluorescent lamps. These ballasts are suitable for<br />
International markets and range in voltage from 120 through 277V, 50 & 60 Hz.<br />
Supply Voltage and Frequency<br />
Each ballast is designed to operate at the nominal voltage shown on<br />
the ADVANCE label. Abnormal deviation from these values will result<br />
in damage to either the ballast or lamp or both. It is therefore necessary<br />
that the voltage applied to ballasts be maintained within the<br />
respective limits shown in the adjoining table.<br />
A ballast subjected to higher than nominal voltages will operate at<br />
increased temperatures. This will result in reduced ballast life. Low<br />
voltage can cause premature lamp failures as well as unreliable lamp<br />
starting.<br />
All ballasts are designed for single frequency operation. Therefore,<br />
best results will be obtained when that ballast is used on the frequency<br />
shown on the ballast label. Frequency limitations are as follows:<br />
Nominal Frequency Limits<br />
60HZ 57.5 to 62.5<br />
50HZ 47.5 to 52.5<br />
Prefix<br />
Code<br />
Letters<br />
Normal<br />
Voltage<br />
Applied Voltage<br />
Limits<br />
Color Label<br />
Identification<br />
H 120 112-127 YELLOW<br />
R 120 112-127 YELLOW<br />
L 120 112-127 YELLOW<br />
S 120 112-127 YELLOW<br />
X 220 210-230 GREEN<br />
M 220/250 210-230 / 235-260 —<br />
Y 240 225-250 ORANGE<br />
V 277 255-290 RED<br />
G 347 322-365 GRAY<br />
CERTIFICATIONS<br />
NOM<br />
All <strong>Advance</strong> ballasts unless otherwise indicated<br />
bear the seal of Underwriters’ Laboratories, Inc. in<br />
accordance with UL935 Standard for Fluorescent<br />
<strong>Ballasts</strong>. File No. E14927<br />
<strong>Advance</strong> ballasts which meet the Canadian<br />
Standards Association requirements for Fluorescent<br />
<strong>Ballasts</strong> per CAN/CSA-22.2 No. 74-92 bear the CSA<br />
seal. File No. LR7310<br />
<strong>Advance</strong> fluorescent ballasts are designed<br />
and manufactured in accordance with the<br />
American National Standards Institute standard<br />
for fluorescent ballasts, ANSI C82.1.<br />
Norma Obligatorio Mexicana<br />
(contact your local salesperson for availability)<br />
Class P <strong>Ballasts</strong> — <strong>Section</strong> 410-73(e) of the National <strong>Electric</strong>al<br />
Code (NEC) requires that all indoor fluorescent fixtures shall incorporate<br />
ballast protection. Those fixtures employing a simple reactive<br />
type ballast are excepted.<br />
The protector is located within the ballast case to prevent physical<br />
damage and tampering.<br />
<strong>Advance</strong> electromagnetic ballasts ordered with ADVAN-guard ®<br />
Class P ballast protection (TP suffix) are equipped with a thermally<br />
actuated automatic reclosing protective device. This revolutionary<br />
development was originally designed and introduced by <strong>Advance</strong>,<br />
and today this Class P device is a requirement of the National<br />
<strong>Electric</strong>al Code in all indoor lighting installations.<br />
Starting<br />
The metal of a fluorescent fixture is a starting aid when properly<br />
grounded. T12 Fluorescent lamps rated at 40 watts or less used for<br />
rapid or trigger start operation must be mounted within 1/2” of a<br />
grounded metal surface. T8 Lamps must be mounted within 3/4”<br />
of a grounded metal surface. All other lamps must be mounted<br />
within 1” of a grounded metal surface.<br />
An important additional factor for proper lamps starting is polarity.<br />
The white ballast lead must be connected to the ground of the power<br />
supply (neutral) and the black lead to the hot line wire. A reversal of<br />
polarity may result in lamp damage or improper lamp starting.<br />
INTERNATIONAL<br />
ELECTROMAGNETIC<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 6-13
T12<br />
INTERNATIONAL ELECTROMAGNETIC<br />
For 30 - 40W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Hz<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog<br />
Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
F30T12 (430mA) 30W<br />
1 220 - 250 50 RS Magnetic MTM-140-TP 50 0.88 20 0.24 50/10 R5 18<br />
F34T12 (460mA) 34W<br />
1 120 60 RS Magnetic HM-140-TP 46 0.89 10 0.39 60/16 T2 20<br />
R-2S40-TP 72 0.88 15 0.63<br />
120 60<br />
RQM-2S40-TP 82 0.88 25 0.74<br />
2 RS Magnetic<br />
60/16<br />
220 or 250 50<br />
MTM-2S40-TP 75 0.83 30 0.39<br />
T2<br />
R5<br />
21<br />
76<br />
277<br />
60<br />
VQM-2S40-TP<br />
78 0.91 15<br />
0.29<br />
T2<br />
21<br />
F40T12 (430mA) 40W<br />
120 60 HM-140-TP 53 0.95 10 0.45<br />
T2<br />
1 RS Magnetic 50/10 20<br />
220 or 250 50 MTM-140-TP 51 0.88 20 0.24<br />
R5<br />
120<br />
60<br />
R-2S40-TP<br />
RQM-2S40-TP<br />
86 0.95 15<br />
96 0.95 25<br />
0.73<br />
0.84<br />
T2<br />
21<br />
2 RS Magnetic TM-2S40-TP • 90 0.91 20 0.75 50/10<br />
50<br />
220 or 250<br />
MTM-2S40-TP 88 0.90 25 0.42<br />
R5<br />
76<br />
277 60<br />
VQM-2S40-TP<br />
91 0.96 20<br />
0.33<br />
T2<br />
21<br />
• Sound Rated B<br />
INTERNATIONAL<br />
ELECTROMAGNETIC<br />
BLUE<br />
BLUE<br />
BLACK<br />
LINE WHITE<br />
YEL-BLUE<br />
Insulate unused power<br />
lead for 300 volts<br />
LAMP<br />
BALLAST<br />
220 V<br />
250 V<br />
Diag. 18<br />
RED<br />
RED<br />
INE<br />
BLUE<br />
BLUE<br />
WHITE<br />
BLK/WHT<br />
LAMP<br />
BALLAST<br />
Diag. Diag. 20 20<br />
RED<br />
RED<br />
Diag. 21<br />
LAMP<br />
LAMP<br />
YELLOW<br />
YELLOW<br />
WHITE BALLAST<br />
LINE<br />
BLACK 220 V<br />
YEL-BLUE 250 V<br />
Insulate unused power lead<br />
for 300 volts<br />
Diag. 76<br />
BLUE<br />
BLUE<br />
RED<br />
RED<br />
DIMENSIONS<br />
Diag. 76<br />
Designation<br />
Length (L)<br />
(inches)<br />
Width (W)<br />
(inches)<br />
Height (H)<br />
(inches)<br />
Mounting (M)<br />
(inches)<br />
H<br />
R-5 9¹₂ 2³₈ 1¹¹₁₆ 8²⁹₃₂<br />
T-2 9¹₂ 2³₈ 1¹₂ 8²⁹₃₂<br />
W<br />
M<br />
L<br />
Case “R”<br />
6-14<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
INTERNATIONAL ELECTROMAGNETIC<br />
For 60 - 110W Lamps<br />
T12/HO<br />
HIGH POWER FACTOR<br />
SOUND RATED C<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Hz<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog<br />
Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
F48T12/HO (800mA) 60W<br />
2 220 or 250 50 RS Magnetic MT-2S110-TP 140 0.87 25 0.70 0/-18 R9 21<br />
F72T12/HO (800mA) 85W<br />
2 220 or 250 50 RS Magnetic MT-2S110-TP 224 0.93 20 1.03 0/-18 R9 21<br />
F96T12/HO (800mA) 110W<br />
2 220 or 250 50 RS Magnetic MT-2S110-TP 280 0.92 15 1.26 0/-18 R9 21<br />
DIMENSIONS<br />
Designation<br />
Length (L)<br />
(inches)<br />
Width (W)<br />
(inches)<br />
Height (H)<br />
(inches)<br />
Mounting (M)<br />
(inches)<br />
R-9 11³₄ 3³₁₆ 2⁵₈ 11⁹₆₄<br />
H<br />
W<br />
M<br />
L<br />
Case “R”<br />
Diag. 21<br />
INTERNATIONAL<br />
ELECTROMAGNETIC<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
6-15
T12 Slimline<br />
INTERNATIONAL ELECTROMAGNETIC<br />
For 40 - 75W Lamps<br />
HIGH POWER FACTOR<br />
SOUND RATED C<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Hz<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog<br />
Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
F48T12 (425mA) 40W<br />
ADM-2E40-S<br />
2 120 60 IS Magnetic<br />
63 0.84 30 0.75 50/10 R-6<br />
ADM-2E40-S-TP<br />
F60T12 (425mA) 50W<br />
2<br />
120<br />
60<br />
277<br />
F64T12 (425mA) 52W<br />
2<br />
120<br />
277<br />
60<br />
F72T12 (425mA) 57W<br />
IS<br />
IS<br />
Magnetic<br />
Magnetic<br />
R-2E75-S-TP<br />
SM-2E75-S-TP<br />
VSM-2E75-S-TP<br />
R-2E75-S-TP<br />
SM-2E75-S-TP<br />
VSM-2E75-S-TP<br />
111 0.94 30<br />
126<br />
112<br />
0.98<br />
0.94<br />
30<br />
25<br />
117 0.95 30<br />
126<br />
116<br />
0.99<br />
0.95<br />
25<br />
25<br />
1.03<br />
1.10<br />
0.45<br />
1.07<br />
1.10<br />
0.45<br />
0/-18<br />
50/10<br />
0/-18<br />
50/10<br />
R-8<br />
R-8<br />
12<br />
12<br />
36<br />
12<br />
36<br />
1 120 60 IS Magnetic A-175-S 60 0.67 50 0.60 50/10 R-5 10<br />
ADM-2E75-S<br />
85 0.59 45 0.81 50/10 R-6<br />
ADM-2E75-S-TP<br />
120<br />
2 60 IS Magnetic R-2E75-S-TP 132 0.94 30 1.18 0/-18<br />
SM-2E75-S-TP 130 0.98 25 1.20<br />
R-8<br />
50/10<br />
277<br />
VSM-2E75-S-TP 129 0.93 25 0.50<br />
F96T12 (425mA) 75W<br />
12<br />
36<br />
1 120 60 IS Magnetic A-175-S 69 0.67 25 0.62 50/10 R-5 10<br />
2<br />
120<br />
277<br />
60<br />
IS<br />
Magnetic<br />
ADM-2E75-S<br />
ADM-2E75-S-TP<br />
111<br />
R-2E75-S-TP 158<br />
SM-2E75-S-TP 170<br />
VSM-2E75-S-TP 159<br />
0.59 40 1.05<br />
R-6<br />
12<br />
0.94 30 1.35 50/10<br />
0.97 25 1.40<br />
R-8<br />
0.92 30 0.60 36<br />
INTERNATIONAL<br />
ELECTROMAGNETIC<br />
DIMENSIONS<br />
Designation<br />
Length (L)<br />
(inches)<br />
Width (W)<br />
(inches)<br />
Height (H)<br />
(inches)<br />
Mounting (M)<br />
(inches)<br />
R-5 9¹₂ 2³₈ 1¹¹₁₆ 8²⁹₃₂<br />
R-6 9¹₂ 3⁷₆₄ 1²⁵₃₂ 8²⁹₃₂<br />
W<br />
R-8 11³₄ 3⁷₆₄ 1²⁵₃₂ 11⁹₆₄ Case “R”<br />
H<br />
M<br />
L<br />
CUTOUT LAMPHOLDER<br />
LINE<br />
WHITE<br />
BLK/WHT<br />
CUTOUT LAMPHOLDER<br />
LAMP<br />
BALLAST<br />
BLUE<br />
BLACK<br />
WHITE<br />
LAMP<br />
BALLAST<br />
BLUE<br />
RED<br />
LINE<br />
BROWN,<br />
WHITE or<br />
YEL-BLUE<br />
BLACK<br />
YELLOW<br />
YELLOW<br />
CUTOUT LAMPHOLDER<br />
LAMP<br />
BALLAST<br />
RED<br />
BLUE<br />
LINE<br />
LAMP<br />
LAMP<br />
Diag. 10<br />
CUTOUT LAMPHOLDER<br />
Diag. 12<br />
CUTOUT LAMPHOLDER<br />
Diag. 36<br />
6-16<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
INTERNATIONAL ELECTROMAGNETIC<br />
For 13 - 40W Lamps<br />
T8,T12,T9<br />
HIGH POWER FACTOR<br />
SOUND RATED A<br />
No. of<br />
Lamps<br />
Input<br />
Volts<br />
Hz<br />
Lamp<br />
Starting<br />
Method<br />
Ballast<br />
Family<br />
Catalog<br />
Number<br />
Input<br />
Power<br />
ANSI<br />
(Watts)<br />
Ballast<br />
Factor<br />
Max.<br />
THD<br />
%<br />
Line<br />
Current<br />
(Amps)<br />
Min.<br />
Starting<br />
Temp.<br />
(°F/°C)<br />
Dim.<br />
Wiring<br />
Dia.<br />
F15T8 (15W)<br />
1 220 60 PH Magnetic XHM-1P20-TP 26 0.89 20 0.12 0/-18 T-2 20<br />
2 220 60 PH Magnetic XM-2SP20-TP 51 0.82 20 0.28 0/-18 T-2 21<br />
F14T12 (14W)<br />
1 220 60 PH Magnetic XHM-1P20-TP 22 0.78 15 0.11 0/-18 T-2 20<br />
2 220 60 PH Magnetic XM-2SP20-TP 45 0.85 10 0.24 0/-18 T-2 21<br />
F15T12 (15W)<br />
1 220 60 PH Magnetic XHM-1P20-TP 23 0.86 15 0.11 0/-18 T-2 20<br />
2 220 60 PH Magnetic XM-2SP20-TP 44 0.79 15 0.25 0/-18 T-2 21<br />
F20T12 (20W)<br />
1 220 60 PH Magnetic XHM-1P20-TP 25 0.72 20 0.12 0/-18 T-2 20<br />
2 220 60 PH Magnetic XM-2SP20-TP 53 0.86 20 0.27 0/-18 T-2 21<br />
F16T9 (40W Circline)<br />
1 220 or 250 50 RS Magnetic MTM-140-TP 51 0.88 20 0.24 50/10 R-5 18<br />
CFT13W/GX23 (PL-S13W, F13BX, CF13DS) or CFQ13W/GX23 (PL-C13W/USA, F13BX23T4, CF13DD)<br />
1 220 50 PH Magnetic XTH-1B13-TP-W 21 0.98 15 0.10 0/-18 R-2 47<br />
LAMP<br />
LAMP<br />
BLK/WHT BLACK<br />
BLUE<br />
BLUE<br />
BLACK<br />
LINE WHITE<br />
YEL-BLUE<br />
Insulate unused power<br />
lead for 300 volts<br />
BALLAST<br />
220 V<br />
250 V<br />
Diag. 18<br />
RED<br />
RED<br />
LINE<br />
BLUE<br />
BLUE<br />
WHITE<br />
BLK/WHT<br />
BALLAST<br />
Diag. Diag. 20 20<br />
RED<br />
RED<br />
Diag. 21<br />
BLUE<br />
BALLAST<br />
WHITE<br />
Diag. 47<br />
LINE<br />
WHITE<br />
INTERNATIONAL<br />
ELECTROMAGNETIC<br />
DIMENSIONS<br />
Designation<br />
Length (L)<br />
(inches)<br />
Width (W)<br />
(inches)<br />
Height (H)<br />
(inches)<br />
Mounting (M)<br />
(inches)<br />
R-2 4³₄ 2⁷₃₂ 1⁵₈ 4³₈+<br />
R-5 9¹₂ 2³₈ 1¹¹₁₆ 8²⁹₃₂<br />
T-2 9¹₂ 2³₈ 1¹₂ 8²⁹₃₂<br />
H<br />
W<br />
Case “R”<br />
M<br />
L<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
6-17
SPECIALTY ELECTROMAGNETIC HID BALLASTS<br />
Specialty Customer Support / Technical Service phone: (+) 1 847 390-5000<br />
Specialty Customer Support fax: (+) 1 847 390-5366<br />
Specialty Technical Support fax: (+) 1 847 768-7768<br />
<strong>Advance</strong> offers an extensive range of High Intensity Discharge ballasts to run ANSI<br />
specification (U.S. style) lamps. These ballasts are suitable for Specialty markets<br />
and range in voltage from 100 through 415V, 50 & 60 Hz.<br />
ADVANCE ® HID Lamp <strong>Ballasts</strong> are available to operate the wide<br />
variety of mercury, metal halide, high pressure sodium and low pressure<br />
sodium lamps available in today’s marketplace.<br />
Like fluorescent, HID lamps are electric discharge lamps. Light is<br />
produced by an arc discharge between two electrodes located at<br />
opposite ends of an arc tube within the lamp’s outer glass envelope.<br />
The ballast is the lamp’s power supply; its purpose is to provide<br />
proper starting and operating voltage and current to initiate and sustain<br />
this arc.<br />
Core & Coil<br />
The basic ballast is the open core & coil which is most often used<br />
as a component within a lighting fixture. The core & coil also forms<br />
the nucleus of the five other ballast configurations detailed in this<br />
section. It consists of either one, two or three copper coils on a core<br />
(or “stack”) of electrical-grade steel laminations. The coils are<br />
assembled to core sections which are then surface-welded together.<br />
At <strong>Advance</strong> Transformer Co. the assembled ballast is vacuum<br />
impregnated with a silica-filled polyester varnish to re-enforce the<br />
electrical insulation, preclude moisture, inhibit noise, and dissipate<br />
heat. Other HID ballast manufacturers apply varnish via a preheatand-dip<br />
process which only puts a thin coat of varnish on the outer<br />
surface of the ballast.<br />
Encapsulated Core & Coil<br />
Where quiet performance is required, the standard open core &<br />
coil ballasts are encapsulated (potted) in a cube-shaped steel can utilizing<br />
Class H (180°C) polyester compound. These ballasts carry a<br />
Class A noise rating up through 175 watts and Class B for 250 and<br />
400 watts. As with the open core & coil, the capacitor (and ignitor<br />
where included) are mounted separately within the fixture.<br />
Replacements<br />
For capacitors, see pages 4-48 to 4-49<br />
For ignitors, see pages 4-50 to 4-53<br />
Special Voltages<br />
For voltage and frequencies not shown in the charts of the following<br />
pages, please contact your <strong>Advance</strong> Sales Representative.<br />
CERTIFICATIONS<br />
Indicates ballast is listed by Underwriters Laboratories,<br />
Inc. in accordance with UL 1029 Standard for HID <strong>Ballasts</strong>.<br />
Each ballast is marked appropriately.<br />
NOM<br />
All HID <strong>Ballasts</strong> are designed and manufactured<br />
in accordance with the American National<br />
Standards Institute Standard for HID <strong>Ballasts</strong>, ANSI<br />
C82.4.<br />
Norma Obligatorio Mexicana.<br />
(contact your local salesperson for availability)<br />
SPECIALTY<br />
HID<br />
6-18<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
50 HZ Core & Coil <strong>Ballasts</strong><br />
(Minimum Starting Temperature –20°F or –30°C)<br />
HID<br />
Mercury<br />
Input<br />
Volts<br />
Catalog ✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Dimensions<br />
Fig A B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
U.L.<br />
Bench<br />
Top Rise<br />
Code<br />
1029<br />
(Pg 5-3)<br />
100 Watt Lamp, ANSI Code H38 or H44<br />
120/<br />
220/240<br />
71A25N1 CWA 125<br />
1.2/<br />
.7/.6<br />
240<br />
3/<br />
2/2<br />
1 1.3 2.6 12 280 7C120M33-R D 5.0<br />
125 Watt Lamp, ANSI Code H42<br />
220/240 71A29R0 CWA 150 .7/.7 255 2/2 A 1 1.7 3.0 14 280 7C140M33-R D 6.0 D/D<br />
175 Watt Lamp, ANSI Code H39<br />
120/<br />
See 175W Metal Halide CWA 71A55NO (page 6-16)<br />
220/240<br />
250 Watt Lamp, ANSI Code H37<br />
120/<br />
220/240<br />
400 Watt Lamp, ANSI Code H33<br />
120/<br />
220/240<br />
1000 Watt Lamp, ANSI Code H36<br />
120/<br />
220/240<br />
A<br />
See 250W Metal Halide CWA 71A57N0 (page 6-16)<br />
See 400W Metal Halide CWA 71A60N1 (page 6-16)<br />
See 1000W Metal Halide CWA 71A65N2 (page 6-16)<br />
B/<br />
B/B<br />
✝ Ordering information:<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-600 core & coil only (no capacitor)<br />
• For CWA circuits, figure is operating current.<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
CAP<br />
CAP<br />
LAMP<br />
LAMP<br />
COM<br />
COM<br />
Fig. A<br />
B<br />
MAX.<br />
A<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
B<br />
MAX.<br />
A<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
LINE V<br />
LAMP<br />
2 13 /16"<br />
4 1 /4"<br />
OPTIONAL)<br />
CAP<br />
LAMP<br />
2 7 /16"<br />
3 1 /2" 3 15 /16"<br />
Fig. 1<br />
(3" x 4" core)<br />
3 7 /8"<br />
4 3 /8" 4 3 /4"<br />
Fig. 2<br />
(4 1 /4" x 4 3 /4" core)<br />
COM<br />
Fig. G<br />
INTERNATIONAL<br />
HID<br />
CAP<br />
LAMP<br />
LINE V<br />
LAMP<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
WELDED BRACKET DIMENSIONS<br />
COM<br />
CAP<br />
LINE V<br />
LINE V<br />
COM<br />
Fig. K<br />
COM<br />
LAMP<br />
LINE V<br />
COM<br />
CAP<br />
CAP<br />
CAP<br />
Fig. M<br />
COM<br />
LAMP<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
1 5.1 1.00 4.50 0.25<br />
2 6.5 1.25 5.75 0.28<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
6-19
HID<br />
HIGH INTENSITY DISCHARGE BALLASTS<br />
50 HZ Core & Coil <strong>Ballasts</strong><br />
(Minimum Starting Temperature –20°F or –30°C)<br />
Metal Halide<br />
Input<br />
Volts<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max<br />
Input<br />
Current<br />
•<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
70 Watt Lamp, ANSI Code M98 or M143<br />
120/<br />
220/240 71A52N2 HX-HPF 95 1.7/<br />
256<br />
1.0/.9<br />
Fuse<br />
Rating<br />
(Amps)<br />
5/<br />
3/3<br />
Wiring<br />
Dia<br />
K<br />
Dimensions<br />
Fig<br />
A<br />
B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
1 1.5 2.8 14 280 7C140M33-R D 5.0 LI533-H4<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
15<br />
U.L. Bench Top<br />
Rise Code 1029<br />
(Pg 5-3)<br />
ADVANCE<br />
Class H<br />
Class N<br />
(180°C)<br />
(200°C)<br />
B/<br />
A/B<br />
—<br />
New<br />
New<br />
INTERNATIONAL<br />
HID<br />
New<br />
N<br />
N<br />
120/<br />
220/240 71A53N0 HX-HPF 129 2.2/<br />
1.2/1.1<br />
120/<br />
220-240 71A55N0 CWA 210 2.0/<br />
1.0<br />
310<br />
250 Watt Lamp, ANSI Code M58 or H37<br />
120/<br />
220-240 71A57N0 CWA 290 2.5/<br />
315<br />
1.3<br />
320 Watt Lamp, ANSI Code M132 or M154 (Pulse-Start)<br />
120/<br />
220-240 71A58N2 Super<br />
CWA<br />
365<br />
394<br />
454<br />
3.1/<br />
1.6<br />
3.3/<br />
1.7<br />
3.9/<br />
2.0<br />
280<br />
350 Watt Lamp, ANSI Code M131 (Pulse-Start)<br />
120/<br />
220-240 71A59N3 Super<br />
CWA<br />
280<br />
400 Watt Lamp, ANSI Code M59 or H33<br />
120/<br />
220-240 71A60N1 CWA 462 4.1/<br />
320<br />
2.1<br />
400 Watt Lamp, ANSI Code M135 or M155 (Pulse-Start)<br />
120/<br />
220-240 71A60N2 Super<br />
CWA<br />
270<br />
1000 Watt Lamp, ANSI Code M47 or H36<br />
120/<br />
220/240 71A65N2 CWA 1090 9.3/<br />
450<br />
5.0/4.5<br />
1500 Watt Lamp, ANSI Code M48<br />
280<br />
150 Watt Lamp, ANSI Code M102 or M142<br />
120/<br />
220/240 71A54N2 HX-HPF 187 3.7/<br />
248<br />
2.0/1.8<br />
175 Watt Lamp, ANSI Code M57 or H39; or 150 Watt Lamp, ANSI Code M107<br />
200 Watt Lamp, ANSI Code M136 (Pulse-Start)<br />
120/<br />
220-240 71A56N3 Super<br />
CWA<br />
7/<br />
4<br />
10/<br />
5/5<br />
250 Watt Lamp, ANSI Code M138 or M153 (Pulse-Start)<br />
120/<br />
220-240 71A57N2 Super<br />
CWA<br />
244<br />
294<br />
2.1/<br />
1.1<br />
2.6/<br />
1.4<br />
280<br />
5/<br />
3<br />
7/<br />
4<br />
10/<br />
5<br />
10/<br />
5<br />
10/<br />
6<br />
10/<br />
5<br />
24/<br />
13/13<br />
1000 Watt Lamp, ANSI Code M141 (Pulse-Start)<br />
120/<br />
220/240 71A65N3 Super<br />
CWA 1090 9.3/<br />
5.0/4.5<br />
285<br />
450<br />
5/<br />
3<br />
6/<br />
3<br />
24/<br />
13/13<br />
K<br />
K<br />
A<br />
M<br />
A<br />
M<br />
M<br />
M<br />
A<br />
M<br />
A<br />
M<br />
A/<br />
1 1.9 3.2 17.5 300 7C175M33-R D 6.0 LI533-H4 15<br />
—<br />
A<br />
C/<br />
1 2.5 4.1 28 240 7C280P30-R D 7.5 LI533-H4 5<br />
—<br />
C/D<br />
1 2.8 4.0 12 450 MD1204-100 O 9.0 —<br />
A/<br />
2 1.9 3.4 17 400 7C180P40-R D 12.5 LI533-H4 2<br />
—<br />
A<br />
2 1.9 3.4 18 400 7C180P40-R D 11.5 —<br />
C/<br />
2 1.8 3.3 20 330 7C200P33-R D 11.5 LI533-H4 5<br />
—<br />
C<br />
2 2.1 3.8 24 400 7C240P40-R D 12.5 LI533-H4<br />
2 2.1 3.8 25.5 400 7C255P40-R D 12.5 LI533-H4<br />
2 2.2 3.7 24 450 MD2409-100 O 14.0 —<br />
2 2.1 3.8 30 345 7C300S34 D 12.3 LI533-H4<br />
8 3.0 5.0 26 525 MD2602-100 O 23.0 —<br />
8 3.0 5.0 26 525 MD2602-100 O 23.0 LI571-H5★<br />
2 Capacitor Set:<br />
MD1802-200<br />
(2) 18mFd Caps<br />
Connected in Parallel<br />
220/240 71A67R2 CWA 1605 7.5/6.9 450 20/20 A 8a 4.4 6.4 36 540<br />
O 32.0 —<br />
[ ]<br />
—<br />
—<br />
2<br />
2<br />
—<br />
2<br />
—<br />
2<br />
—<br />
C/<br />
C<br />
D/<br />
A<br />
A/<br />
A<br />
C/<br />
C<br />
D/<br />
D<br />
C/<br />
E<br />
D/<br />
C/C<br />
D/<br />
C/C<br />
E/E<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
A/<br />
A/A<br />
A/<br />
A/A<br />
A/A<br />
See Wiring Diagrams on Page 6-21<br />
6-20<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
HIGH INTENSITY DISCHARGE BALLASTS<br />
50 HZ Core & Coil <strong>Ballasts</strong><br />
(Minimum Starting Temperature –40°F or –40°C)<br />
HID<br />
High Pressure Sodium<br />
Input<br />
Volts<br />
Cap Catalog<br />
Number<br />
50 Watt Lamp, ANSI Code S68<br />
220/240 71A78R1 HX-HPF 66 .6/.5 120 2/2 K 1 1.3 2.6 6.0 280 7C060L33 D 5.0 LI551-H4 2 A/A<br />
70 Watt Lamp, ANSI Code S62<br />
120/<br />
220/240<br />
71A79N1 HX-HPF 94<br />
100 Watt Lamp, ANSI Code S54<br />
120/<br />
220/240<br />
71A80N1 HX-HPF 130<br />
150 Watt Lamp, ANSI Code S55<br />
120/<br />
220/240<br />
1.4/<br />
0.8/.7<br />
2.4/<br />
1.3/1.2<br />
125<br />
120<br />
4/<br />
2/2<br />
6/<br />
4/4<br />
1 1.9 3.1 8.4 280 7C084L33-R D 6.0 LI551-H4 2<br />
1 2.4 3.7 12 280 7C120M33-R D 8.0 LI551-H4 2<br />
1 3.0 4.2 17.5 260 7C175M33-R D 7.5 LI551-H4 2<br />
150 Watt Lamp, ANSI Code S56<br />
220/240 71A81R6 R-HPF 175 1.4/1.5 230 4/4 G 4 2.2 3.7 20 240 7C200P33-R D 6 LI501-H4 2 B/C<br />
250 Watt Lamp, ANSI Code S50<br />
120/<br />
220-240<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
71A81N2 HX-HPF 188<br />
71A82N1 CWA 300<br />
400 Watt Lamp, ANSI Code S51<br />
Max<br />
Input<br />
Current<br />
3.0/<br />
1.7/1.6<br />
2.8/<br />
1.4<br />
•<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
120<br />
190<br />
Fuse<br />
Rating<br />
(Amps)<br />
8/<br />
5/4<br />
7/<br />
4<br />
Wiring<br />
Dia<br />
K<br />
K<br />
K<br />
M<br />
Dimensions<br />
Fig<br />
A<br />
B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
2 2.1 3.7 40 240 7C400P30-R D 12.0 LI501-H4 2<br />
U.L. Bench Top<br />
Rise Code 1029<br />
(Pg 5-3)<br />
ADVANCE<br />
Class H<br />
Class N<br />
(180°C)<br />
(200°C)<br />
A/<br />
A/A<br />
A/<br />
A/A<br />
C/<br />
B/B<br />
D/<br />
C<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
120/<br />
220-240<br />
71A84N3<br />
4.0/<br />
10/<br />
CWA 465<br />
190<br />
M 2 2.5 4.1 64 280<br />
2.0<br />
6<br />
7C640S28-R<br />
D<br />
15.0<br />
LI501-H4<br />
2<br />
D/<br />
D<br />
—<br />
N<br />
2 Capacitor Set:<br />
MD1408-230<br />
(2) 14mFd Caps<br />
Connected in Parallel<br />
220/240 71A87R3 CWA 1100 6.0/5.6 435 15/15 M 8a 4.3 6.3 28 580<br />
O 35.5 LI571-H5★ 2 E/E<br />
✝ Ordering information:<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-510D includes core & coil with welded bracket and dry-film capacitor<br />
-500 includes core & coil with oil-filled capacitor<br />
-510 includes core & coil with welded bracket and oil-filled capacitor<br />
-600 core & coil only (no capacitor)<br />
✝✝ Each ballast requiring an ignitor is furnished as standard with the Short<br />
Range ignitor model shown for use within fixtures. If a Long Range ignitor<br />
is required for remote mounting, specify on order. See pages 5-50 to 5-53<br />
for additional information.<br />
• For HX and R circuits, figure is highest of starting, operating or open circuit<br />
current. For CWA circuits, figure is operating current.<br />
★ Equipped with an auto-reset thermal protector to prevent<br />
ignitor from overheating in the event of lamp failure.<br />
N Dual rated Class H (180°C) / ADVANCE Class N (200°C) insulation system.<br />
Refer to page 5-3 for additional information.<br />
3 7 /8"<br />
1000 Watt Lamp, ANSI Code S52<br />
B<br />
MAX.<br />
4 3 /8" 4 3 /4"<br />
A<br />
4 1 /4"<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
Fig. 2<br />
(4¹₄" 1 /4" x 44³₄" 3 /4" core)<br />
B<br />
MAX.<br />
4 3 /32"<br />
A<br />
2 5 /32"<br />
Fig. 6<br />
(2" x 44" " core)<br />
B<br />
MAX.<br />
3 7 /8"<br />
4 1 /4"<br />
4 3 /8"<br />
5 3 /8" 6 "<br />
2 7 /16"<br />
A<br />
B<br />
MAX.<br />
3 1 /2" 3 15 /16"<br />
8 Holes cleared for<br />
#10 thru-bolts<br />
Fig. Fig. 8 and 8 8a<br />
(4(4¹₄" 1 /4" x 6" core)<br />
[ ]<br />
A<br />
2 13 /16"<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
Fig. 1<br />
(3" x 4" core)<br />
2 1 /4"<br />
2 13 /16"<br />
WELDED BRACKET DIMENSIONS<br />
2 13 /16"<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
1 5.1 1.00 4.50 0.25<br />
2 6.5 1.25 5.75 0.28<br />
8 7.8 2.75 6.13 0.25<br />
8a 7.8 4.50 6.75 0.31<br />
B<br />
A<br />
4 Holes cleared for<br />
#10 thru-bolts<br />
3 3 /8"<br />
Fig. 4<br />
13 /16 " x 3 3 /8<br />
(2¹³₁₆" x 3³₈ Reactor Core Core) )<br />
A/A<br />
INTERNATIONAL<br />
HID<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
6-21
HID<br />
100/200V 60 HZ CORE & COIL BALLASTS<br />
For Southern Japan<br />
(Minimum Starting Temperature –20°F or –30°C)<br />
Mercury<br />
Input<br />
Volts<br />
Catalog ✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Dimensions<br />
Fig A B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
U.L.<br />
Bench<br />
Top Rise<br />
Code<br />
1029<br />
(Pg 5-3)<br />
INTERNATIONAL<br />
HID<br />
N<br />
100 Watt Lamp, ANSI Code H38 or H44<br />
100/200 71A25Y1 CWA 120 1.3/.7 250 4/2 A 1 1.1 2.3 10 280 7C100M33-R D 4.0 D/E<br />
Metal Halide<br />
Input<br />
Volts<br />
Catalog✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max•<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Cap Catalog<br />
Number<br />
35/39 Watt Lamp, ANSI Code M130<br />
100 71A50Y5-P HX-HPF 54 1.1 235 2 K 6 .9 1.8 36 120 7C360M12 D 3.5 LI533-H4<br />
70 Watt Lamp, ANSI Code M98 or M143<br />
100/200 71A52Y2 HX-HPF 89 2.0/1.0 253 5/3 K 1 1.5 1.7 10 280 7C100M33-R D 4.5 LI533-H4 10 A/A —<br />
70 Watt Lamp, ANSI Code M139 (Philips CDM70/T6, CDM70/TD)<br />
100/200 71A52Y1 HX-HPF 92 2.3/1.2 255 6/3 K 1 1.5 2.7 10 330 7C100M33-R D 4.8 LI533-H4 10 A/A —<br />
100 Watt Lamp, ANSI Code M90<br />
100/200 71A53Y3 CWA 126 1.3/.7 233 3/2 M 1 1.6 1.8 10 300 7C100M33-R D 5.0 LI533-H4<br />
150 Watt Lamp, ANSI Code M102 or M142<br />
100/200 71A54Y2 HX-HPF 185 4.4/2.2 240 10/5 K 1 2.5 4.1 16 280 7C160M33 D 7.5 LI533-H4<br />
175 Watt Lamp, ANSI Code M57 or H39; or 150 Watt Lamp, ANSI Code M107<br />
100/200 71A55Y0 CWA 210 2.2/1.1 295 5/3 A 1 2.4 3.5 10 400 7C100M40-R D 7.1 —<br />
250 Watt Lamp, ANSI Code M58 or H37<br />
100/200 71A57Y0 CWA 285 3.0/1.5 295 8/4 A 2 1.7 3.1 15 400 7C150M40-R D 10.0 — — A/A<br />
320 Watt Lamp, ANSI Code M132 or M154 (Pulse-Start)<br />
Super<br />
100/200 71A58Y2<br />
368 3.7/1.9 267 10/5 M 2 1.8 3.7 21 345 7C210P34-R D 11.0 LI533-H4 5 B/B<br />
CWA<br />
400 Watt Lamp, ANSI Code M59 or H33<br />
100/200 71A60Y1 CWA 458 5.0/2.5 295 15/7 A 2 2.1 3.6 24 400 7C240P40-R D 12.0 — — C/D<br />
1000 Watt Lamp, ANSI Code M47 or H36<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Dimensions<br />
7C400P30-R<br />
200 71A65Y6 CWA 1090 5.9 425 15 P 8 3.2 5.0 20 560<br />
D 23.0 —<br />
(Two in Series)<br />
Fig<br />
A<br />
B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Dry<br />
or<br />
Oil<br />
Total<br />
Weight<br />
(Ibs)<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Part<br />
Number<br />
Max<br />
Dist<br />
To<br />
Lamp<br />
(ft)<br />
15<br />
5<br />
10<br />
—<br />
—<br />
U.L. Bench Top<br />
Rise Code 1029<br />
(Pg 5-3)<br />
ADVANCE<br />
Class H<br />
Class N<br />
(180°C)<br />
(200°C)<br />
100/200 71A50Y1 HX-HPF 53 1.3/.7 248 3/2 K 1 .9 2.0 10 280 7C100M33-R D 3.0 LI533-H4 5 A/A —<br />
B<br />
B/B<br />
C/A<br />
B/B<br />
E<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
A<br />
B<br />
MAX.<br />
3 7 /8"<br />
1 /4"<br />
A<br />
4 3 /8"<br />
5 3 /8" 5 3 /4"<br />
8 Holes cleared for<br />
#10 thru-bolts<br />
1 1 /4"<br />
Fig. 3<br />
(4 1 /4" x 5 3 /4" core)<br />
WELDED BRACKET DIMENSIONS<br />
Ballast<br />
Dimensions Fig<br />
L W M S<br />
1, 6 5.1 1.00 4.50 0.25<br />
2 6.5 1.25 5.75 0.28<br />
3, 8 7.8 2.75 6.13 0.25<br />
For Figures 1, 2, 6 and 8 – See Page 6-21<br />
6-22<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
100/200V 50 HZ CORE & COIL BALLASTS<br />
For Northern Japan<br />
(Minimum Starting Temperature –20°F or –30°C)<br />
HID<br />
Mercury<br />
Input<br />
Volts<br />
Catalog ✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Wiring<br />
Dia<br />
Dimensions<br />
Fig A B<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
Min<br />
Volt<br />
Cap Catalog<br />
Number<br />
Dry<br />
or<br />
Oil<br />
U.L.<br />
Bench<br />
Total<br />
Top Rise<br />
Weight<br />
Code<br />
(Ibs)<br />
1029<br />
(Pg 5-3)<br />
100 Watt Lamp, ANSI Code H38 or H44<br />
100/200 71A25M1 CWA 125 1.3/.7 250 4/2 A 1 1.3 2.6 12 300 7C120M33-R D 4.5 A/A<br />
Metal Halide<br />
Input<br />
Volts<br />
Catalog ✝<br />
Number<br />
Circuit<br />
Type<br />
Watts<br />
Input<br />
35/39 Watt Lamp, ANSI Code M130<br />
Max •<br />
Input<br />
Current<br />
Nom<br />
Open<br />
Circuit<br />
Voltage<br />
Fuse<br />
Rating<br />
(Amps)<br />
Cap Catalog<br />
Number<br />
100/200 71A50M1 HX-HPF 54 1.3/.7 250 3/2 K 1 1.1 2.2 12 280 7C120M33-R D 3.9 LI533-H4<br />
70 Watt Lamp, ANSI Code M98 or M143<br />
Wiring<br />
Dia<br />
Dimensions<br />
100/200 71A52M2 HX-HPF 90 1.9/1.0 258 5/3 K 1 1.5 1.7 14 280 7C140M33-R D 4.5 LI533-H4<br />
100/200 71A55M0 CWA 215 2.2/1.1 295 5/3 A 1 3.0 4.2 12 450 MD1204-100 O 9.0 —<br />
Fig<br />
A<br />
COM<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
CAP<br />
B<br />
CAP<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
Mfd<br />
Non-PCB Capacitor<br />
(Page 5-48 to 5-49)<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
Min<br />
Volt<br />
CAP<br />
Fig. A<br />
Fig. K<br />
CAP<br />
COM<br />
LAMP<br />
COM<br />
LAMP<br />
LAMP<br />
LAMP<br />
Dry<br />
or<br />
Oil<br />
LINE V<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
Total<br />
Weight<br />
(Ibs)<br />
LINE V<br />
LINE V<br />
LINE V<br />
COM<br />
CAP<br />
Ignitor ✝✝<br />
(Page 5-50 to 5-53)<br />
Max<br />
Dist<br />
Part<br />
To<br />
Number<br />
Lamp<br />
(ft)<br />
70 Watt Lamp, ANSI Code M139 (Philips CDM70/T6, CDM70/TD)<br />
100/200 71A52M1 HX-HPF 90 1.9/1.0 235 5/3 K 1 1.5 3.0 14 300 7C140M33-R D 5.0 LI533-H4<br />
100 Watt Lamp, ANSI Code M90<br />
100/200 71A53M0 HX-HPF 129 2.9/1.5 280 7/4 K 1 1.9 3.2 20 240 7C200P33-R D 5.8 LI533-H4<br />
150 Watt Lamp, ANSI Code M102 or M142<br />
100/200 71A54M2 HX-HPF 185 4.4/2.2 240 10/5 K 1 2.5 4.1 35 240 7C350P24 D 7.5 LI533-H4<br />
175 Watt Lamp, ANSI Code M57 or H39; or 150 Watt Lamp, ANSI Code M07<br />
250 Watt Lamp, ANSI Code M58 or H37<br />
100/200 71A57M0 CWA 292 3.0/1.5 295 8/4 A 2 1.9 3.4 18 400 7C180P40-R D 11.0 — — A/A<br />
320 Watt Lamp, ANSI Code M132 (Pulse-Start)<br />
100/200 71A58M2<br />
Super<br />
CWA<br />
400 Watt Lamp, ANSI Code M59 or H33<br />
100/200 71A60M2 CWA 460 5.0/2.5 295 15/7 A 3 2.4 4.0 26 525 MD2602-100 O 14.0 — — C/D<br />
CAP<br />
CAP<br />
CAP<br />
Fig. P<br />
Fig. M<br />
COM<br />
CAP<br />
5<br />
15<br />
2<br />
—<br />
LAMP 1<br />
LAMP 2<br />
LAMP<br />
U.L.<br />
Bench<br />
Top<br />
Rise<br />
Code<br />
1029<br />
(pg 5-3)<br />
370 3.7/1.9 280 10/5 M 2 2.1 3.9 24 400 7C240P40-R D 12.7 LI533-H4 2 A/B<br />
✝ Ordering information:<br />
Original equipment ballasts - add proper suffix to catalog number:<br />
-500D includes core & coil with dry-film capacitor<br />
-500 includes core & coil with oil-filled capacitor<br />
✝✝ Each ballast requiring an ignitor is furnished as standard with the<br />
Short Range ignitor model shown for use within fixtures. If a<br />
Long Range ignitor is required for remote mounting, specify on<br />
order. See pages 5-50 to 5-53 for additional information.<br />
• For HX circuits, figure is highest of starting,<br />
operating or open circuit current. For CWA<br />
circuits, figure is operating current.<br />
N Dual rated Class H (180°C) / ADVANCE Class N (200°C) insulation system.<br />
Refer to page 5-3 for additional information.<br />
5<br />
10<br />
A/A<br />
A/A<br />
A/A<br />
A/A<br />
D/D<br />
A/A<br />
LAMP<br />
LAMP<br />
INTERNATIONAL<br />
HID<br />
6-23
XITANIUM LED ELECTRONIC DRIVERS<br />
LED Drivers are specialized power supplies serving as both brain and muscle for solid-state lighting<br />
systems. <strong>Advance</strong> is the R&D leader in LED driver technology, with a wide range of innovative products<br />
available today that are integral elements of high quality, energy-efficient solid-state lighting solutions.<br />
XITANIUM<br />
LED<br />
LED 230V Driver Data Ambient Temp.<br />
Nom. Max.<br />
Certifications<br />
Max. Min.<br />
Max. Dim./<br />
Output<br />
Input Catalog<br />
Line Input Power<br />
Env.<br />
Output Output Output Voltage Min. Max.<br />
THD Wiring<br />
Current<br />
Volts Number<br />
Current Power Factor<br />
Rating<br />
Power Voltage (Vdc)<br />
(°F/°C)<br />
CE<br />
%<br />
Dia.<br />
(Adc)<br />
(°F/°C)<br />
(Amps) (Watts)<br />
(W) (Vdc)<br />
Luxeon Drivers<br />
12 1.0 2.8 - 33.0 0.35 -40/-40 140/60 230 LED230A0350C33F ✓ 0.07 15.0 20 0.9 Fig. C/05 Dry<br />
12 1.0 2.8 - 33.0 0.35 -40/-40 140/60 230 LED230A0350C33FO ✓ 0.07 15.0 20 0.9 Fig. C/05 Dry, Damp<br />
17 1.0 2.8 - 24.6 0.70 -40/-40 140/60 230 LED230A0700C24F ✓ 0.10 21.5 20 0.9 Fig. C/05 Dry<br />
17 1.0 2.8 - 24.6 0.70 -40/-40 140/60 230 LED230A0700C24FO ✓ 0.10 21.5 20 0.9 Fig. C/05 Dry, Damp<br />
25 3.0 2.8 - 24.6 1.05 -40/-40 140/60 230 LED230A1050C24F ✓ 0.30 25.5 20 0.9 Fig. B/02 Dry<br />
40 5.0 2.8 - 24.6 1.75 -40/-40 140/60 230 LED230A1750C24F ✓ 0.47 40.8 20 0.9 Fig. B/02 Dry<br />
67 10.0 2.8 - 24.0 2.80 -40/-40 140/60 230 LED230A2800C24FO ✓ 0.35 80.0 20 0.9 Fig. D/05 Dry, Damp<br />
80 10.0 2.8 - 24.0 3.15 -40/-40 140/60 230 LED230A3150C24FO ✓ 0.48 100.0 20 0.9 Fig. D/05 Dry, Damp<br />
Fig. B<br />
Diag. 02<br />
INTERNATIONAL<br />
LED DRIVERS<br />
Fig. C<br />
Diag. 05<br />
Fig. D<br />
6-24<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
Xitanium LED ELECTRONIC DRIVERS<br />
LED DRIVERS<br />
XITANIUM<br />
1<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
Xitanium LED ELECTRONIC DRIVERS<br />
CONTENTS<br />
General Driver Information.................................................................7-2<br />
Driver Specifications ..........................................................................7-3<br />
Corporate Offices<br />
(800) 322-2086<br />
Customer Support/Technical Service<br />
(800) 372-3331 • (+) 1 847 390-5000 (International)<br />
LED DRIVERS<br />
XITANIUM<br />
Visit our web site at www.advancetransformer.com<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 7-1
LED<br />
Xitanium LED ELECTRONIC DRIVERS<br />
CENTIUM ®<br />
LED Driver Data<br />
Min. / Max.<br />
Input Input<br />
Certifications<br />
Max. Dim./<br />
Output Output Output Ambient Input Catalog<br />
Current Power Power<br />
THD Wiring<br />
Power (W) Voltage Current Temperature Volts Number<br />
Max Max Factor<br />
UL48<br />
%<br />
Dia.<br />
Max. Min.<br />
(V)<br />
(Amps) (°C / °F)<br />
(A) (W)<br />
Luxeon Drivers<br />
10.0 1.0 2.8 ~ 28.0 0.35 -40/-40 120 LED120A0350C28FO ✔ ✔ ✔ 0.12 12.5 20 0.9 Fig. A/01<br />
12.0 1.0 2.8 ~ 32.6 0.35 120 LED120A0350C33F ✔ ✔ ✔ 0.14 15.0 20 0.9 Fig. A/01<br />
17.2 2.0 2.8 ~ 24.6 0.70 120 LED120A0700C24F ✔ ✔ ✔ 0.20 21.5 20 0.9 Fig. A/02<br />
17.2 2.0 2.8 ~ 24.6 0.70<br />
-40°C / 60°C<br />
120 LED120A0700C24FO ✔ ✔ ✔ 0.20 21.5 20 0.9 Fig. A02<br />
25.5 3.0 2.8 ~ 24.6 1.05<br />
-40°F / 140°F<br />
120 LED120A0024V10F ✔ ✔ ✔ 0.30 31.9 20 0.9 Fig. B/01<br />
40.8 5.0 2.8 ~ 24.6 1.75 120 LED120A0024V18F ✔ ✔ ✔ 0.47 51.0 20 0.9 Fig. B/01<br />
- 120 ✔ ✔ ✔ 0.98 Fig. D/05<br />
100.0 0.1 2.8 ~ 24.0 4.16 230 LEDINTA0024V41FO 0.51 117.0 20 0.9 Fig. D/05<br />
- 277 ✔ ✔ ✔ 0.42 Fig. D/05<br />
12VDC LED Systems<br />
12.0 2.0 12 - -40/-40 120 LED120A0012V10F ✔ ✔ ✔ 0.13 15.0 20 0.9 Fig. C/05<br />
25.5 2.3 12 - 120 LED120A0012V21F ✔ ✔ ✔ 0.18 21.5 20 0.9 Fig. B/02<br />
60.0 10.0 12 - -40°C / 60°C 120 LED120A0012V50F ✔ ✔ ✔ 0.63 75.0 20 0.9 Fig. D/05<br />
12 - -40°F / 140°F 120 ✔ ✔ ✔ 0.61 Fig. D/05<br />
60.0 0.1 12 - 230 LEDINTA0012V50FO 0.32 73.0 20 0.9 Fig. D/05<br />
12 - 277 ✔ ✔ ✔ 0.26 Fig. D/05<br />
24VDC LED Systems<br />
17.0 2.4 24 - -40/-40 120 LED120A0024V07F ✔ ✔ ✔ 0.18 21.5 20 0.9 Fig. A/01<br />
17.0 2.4 24 - 120 LED120A0700C24FO ✔ ✔ ✔ 0.18 21.5 20 0.9 Fig. A/02<br />
25.5 2.3 24 - 120 LED120A0024V10F ✔ ✔ ✔ 0.27 31.9 20 0.9 Fig. B/02<br />
40.8 5.6 24 - -40°C / 60°C 120 LED120A0024V18F ✔ ✔ ✔ 0.43 51.0 20 0.9 Fig. B/05<br />
80.0 10 24 - -40°F / 140°F 120 LED120A0024V33F ✔ ✔ ✔ 0.83 100.0 20 0.9 Fig. D/05<br />
- 120 ✔ ✔ ✔ 0.98 Fig. D/05<br />
100.0 0.1 24 - 230 LEDINTA0024V41FO 0.51 117.0 20 0.9 Fig. D/05<br />
- 277 ✔ ✔ ✔ 0.42 Fig. D/05<br />
Dimming (0-10V Dimming)<br />
25.5 15 10.4 ~ 24.6 1.05 -40/-40 -40°C / 60°C 120 LED120A0024V10D* ✔ ✔ ✔ 0.30 31.9 20 0.9 Fig. B/03<br />
25.5 15 24 - -40°F / 140°F 120 LED120A0024V10D* ✔ ✔ ✔ 0.27 31.9 20 0.9 Fig. B/03<br />
Env.<br />
Rating<br />
Dry, Damp<br />
Dry<br />
Dry<br />
Dry, Damp<br />
Dry<br />
Dry<br />
Dry, Damp<br />
Dry, Damp<br />
Dry<br />
Dry, Damp<br />
Dry, Damp<br />
Dry<br />
Dry, Damp<br />
Dry<br />
Dry<br />
Dry<br />
Dry, Damp<br />
Dry<br />
Dry<br />
* For complete specifications on dimming driver, see <strong>Advance</strong>, Form No. LE-6010 available at www.ledcentral.com<br />
LED DRIVERS<br />
XITANIUM<br />
7-2<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
Xitanium LED ELECTRONIC DRIVERS<br />
LED<br />
Diag. 01<br />
Fig. A<br />
Diag. 02<br />
Fig. B<br />
Diag. 03<br />
Fig. C<br />
Diag. 05<br />
LED DRIVERS<br />
XITANIUM<br />
Fig. D<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109<br />
7-3
REFERENCE MATERIALS<br />
Contents<br />
<strong>Advance</strong> Warranty ...............................................................................8-ii<br />
Industry Terms..........................................................................8-1 to 8-3<br />
Ballast Specifications ............................................................8-4 to 8-22<br />
Fixed Light Output <strong>Electronic</strong> (<strong>Section</strong> I) .........................8-5 to 8-16<br />
Controlled Light Output <strong>Electronic</strong> (<strong>Section</strong> II) ..............8-17 to 8-19<br />
HID (<strong>Section</strong> III) .........................................................................8-20<br />
<strong>Electronic</strong> HID [Metal Halide] (<strong>Section</strong> IV)..................................8-21<br />
Xitanium LED Drivers (<strong>Section</strong> V)...............................................8-22<br />
Compact Fluorescent Lamp Reference Guide..................................8-43<br />
Note: For Index pages, See pages 8-23 to 8-43<br />
Corporate Offices<br />
(800) 322-2086<br />
Customer Support/Technical Service<br />
(800) 372-3331 • (+) 1 847 390-5000 (International)<br />
Visit our web site at www.advancetransformer.com<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-i
WARRANTY<br />
ADVANCE ® Lamp Ballast Limited Warranty<br />
<strong>Advance</strong> Transformer Co. (“<strong>Advance</strong>”), 10275 W. Higgins Road, Rosemont, IL 60018 warrants that its lamp ballasts will be<br />
free from defects in material and workmanship from the date of manufacture by <strong>Advance</strong> for the following periods.<br />
(2) Years<br />
Standard Magnetic Fluorescent<br />
High Intensity Discharge (HID)<br />
Magnetic Fluorescent & HID Sign<br />
Matchbox (case temperature 65°C or less)<br />
AmbiStar (case temperature 65°C or less)<br />
(3) Years<br />
Mark III Magnetic Fluorescent<br />
E-PAK Magnetic Fluorescent<br />
Centium® <strong>Electronic</strong> 90C T5/HO (case temperature between 71°C and 90°C)<br />
SmartMate® Compact Fluorescent (case temperature between 76°C and 85°C)<br />
<strong>Electronic</strong> Sign (case temperature 90°C or less)<br />
e-Vision® <strong>Electronic</strong> HID (case temperature between 76°C and 85°C)<br />
(5) Years<br />
Standard <strong>Electronic</strong> (case temperature 70°C or less)<br />
Centium® <strong>Electronic</strong> (case temperature 70°C or less)<br />
Centium® <strong>Electronic</strong> 90C T5/HO (case temperature 70°C or less)<br />
Optanium <strong>Electronic</strong> (case temperature 70°C or less)<br />
Mark 5 <strong>Electronic</strong> (case temperature 70°C or less)<br />
SmartMate® Compact Fluorescent (case temperature 75°C or less)<br />
PowrKut® Low Frequency <strong>Electronic</strong> (case temperature 90°C or less)<br />
Mark 7 0-10V <strong>Electronic</strong> Dimming (case temperature 70°C or less)<br />
Mark 10 Powerline <strong>Electronic</strong> Dimming (case temperature 70°C or less)<br />
ROVR <strong>Electronic</strong> Dimming (case temperature 70°C or less)<br />
e-Vision® <strong>Electronic</strong> HID (case temperature 75°C or less)<br />
Xitanium® LED Drivers<br />
This warranty is conditioned upon proper storage, installation,<br />
use and maintenance. This warranty is not applicable<br />
to any ballast which is not installed and operated in accordance<br />
with the current edition of The National <strong>Electric</strong> Code<br />
(NEC), the Standards for Safety of Underwriters’<br />
Laboratory, Inc. (UL), the Standards for the American<br />
National Standards Institute (ANSI), and with <strong>Advance</strong>’s<br />
instructions and guidelines for the ballast. This warranty is<br />
not applicable to any ballast subjected to abnormal stresses<br />
and operating conditions.<br />
<strong>Advance</strong> shall correct any defects, at <strong>Advance</strong>’s option,<br />
by either repairing any defective part or parts or by replacing<br />
any defective part or parts or by making available a new<br />
replacement ballast.<br />
The conditions of any tests concerning any ballast which<br />
is claimed to have not performed to this warranty shall be<br />
mutually agreed upon in writing and <strong>Advance</strong> shall be notified<br />
of, and may be represented at any such tests. This<br />
express limited warranty is extended by <strong>Advance</strong> only to the<br />
original or first end-user purchaser.<br />
Warranty claims are to be made in accordance with<br />
<strong>Advance</strong>’s published Warranty Service Program.<br />
NO IMPLIED STATUTORY WARRANTY OF MER-<br />
CHANTABILITY OR FITNESS FOR A PARTICULAR PUR-<br />
POSE SHALL APPLY BEYOND THE AFOREMENTIONED<br />
WARRANTY PERIOD. The foregoing warranty is exclusive<br />
of all other statutory, written or oral warranties, and no<br />
other warranties of any kind, statutory or otherwise, are<br />
given or herein expressed. This warranty sets forth<br />
<strong>Advance</strong>’s responsibilities regarding the ballast and<br />
claimant’s exclusive remedy.<br />
LIMITATION OF LIABILITY. <strong>Advance</strong> will not under any<br />
circumstances whether as a result of breach of contract,<br />
breach of warranty, tort, strict liability or otherwise be liable<br />
for consequential, incidental, special or exemplary damages<br />
including but not limited to, loss of profits or revenues, loss<br />
of use of ballast or any other goods or associated equipment<br />
or damage to any associated equipment, cost of capital,<br />
cost of substitute products, facilities of services, down<br />
time cost, or claims of claimant’s customers.<br />
<strong>Advance</strong>’s liability on any claim of any kind for any loss<br />
or damages arising out of, resulting from or concerning any<br />
aspect of this agreement of from the product or services<br />
furnished hereunder shall not exceed the price of the specific<br />
ballast or ballasts which gives rise to the claim.<br />
This warranty gives the claimant specific legal rights.<br />
The claimant may also have other rights which vary from<br />
state to state.<br />
REFERENCE<br />
MATERIALS<br />
8-ii<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
INDUSTRY TERMS<br />
5-Tap - An HID ballast that allows for a choice of five different input<br />
voltages<br />
AC (Alternating Current) - The common form of electricity from<br />
power plant to home/office. Its direction is reversed 60 times per<br />
second in the U.S.; 50 times in Europe<br />
AllnGaP - The preferred LED (Light Emitting Diode) chip technology<br />
containing Aluminum, Indium, Gallium, and Phosphorous to produce<br />
red, orange and amber-colors.<br />
Ambient Sound Levels - "Background noise" generated by electrical<br />
equipment operating in a building.<br />
Ambient Temperature - Temperature of the atmosphere of the surrounding<br />
environment.<br />
Ampere ("Amp") - A measure of electrical current<br />
ANSI (American National Standards Institute) - Group that<br />
generates voluntary product performance standards for many U.S.<br />
industries.<br />
ANSI Watts - System wattage as measured utilizing a reference ballast<br />
and lamps on a bench top in open air as prescribed by ANSI<br />
C82.2<br />
Anti-Arc Circuit - Circuitry used to detect and limit arcing of ballast<br />
output leads<br />
Anti-Striation Circuit - Circuitry used to prevent striations or spiraling<br />
in energy saving lamps due to low temperature or low current<br />
operation<br />
Arc (Lamp) - Intense luminous discharge formed by the passage of<br />
electric current across a space between electrodes.<br />
Auto-Restrike - Circuitry used to restart the lamps without resetting<br />
the power to the ballast<br />
Autotransformer - Tapped winding transformer that changes the<br />
voltage available to the voltage required by a particular load<br />
Ballast - Device for starting and regulating fluorescent and high<br />
intensity discharge lamps.<br />
Ballast Cycling - Undesirable condition under which the ballast<br />
turns lamps on and off (cycles) due to the overheating of the thermal<br />
switch inside the ballast. This may be due to incorrect lamps,<br />
improper voltage being supplied, high ambient temperature around<br />
the fixture, or the early stage of ballast failure.<br />
Ballast Efficacy Factor (BEF) - Measure used to compare various<br />
lighting systems based upon light output and power input. Higher<br />
BEF is favorable. BEF = Ballast Factor x 100 / Input Watts<br />
Ballast Factor - Measure of light output from lamp operated by<br />
commercial ballast, as compared to a laboratory standard reference<br />
ballast.<br />
Ballast Losses - Power that is supplied to the ballast but is not converted<br />
into light energy.<br />
Ballast Noise "Hum" - Sound made by operating Core & Coil assemblies<br />
in both electromagnetic and electronic ballasts, generated by<br />
the vibration of laminations in the electromagnetic field that transforms<br />
the voltage and current used by discharge lamps. The sound<br />
made by high frequency electronic ballasts is lower and any noise<br />
made by models with electronic power factor correction circuits is<br />
inaudible.<br />
Ballast Regulation - The ability of a ballast to control lamp wattage<br />
(and therefore light output) when subject to changes in line voltage.<br />
Bin - In LED's, the systematic dividing of distribution of performance<br />
parameters (Flux, Color or CCT, and Vf) in to smaller groups<br />
that meet aesthetic requirements of the assembly.<br />
Binning - In LED's, the subdivision of the manufactured "distribution"<br />
into bins common operating parts (color, flux, forward voltage)<br />
Canadian Energy Standards - Indicates the ballast complies with<br />
the Canadian Energy Standards and meets the requirements of<br />
CAN/CSA-C654-M91<br />
Canadian Standards Association (CSA) - Association that generates<br />
product performance and safety standards for many Canadian<br />
industries.<br />
Capacitor - Device in ballast that stores electrical energy.<br />
Centigrade (C) - Celsius temperature scale where 0°C = 32°F and<br />
100°C = 212°F.<br />
Chip - A very small square of semi-conducting material. Also known<br />
as a die, it is the active light-emitting component of an LED.<br />
Circle E - Marking on ballast that shows compliance with Federal<br />
Ballast Energy Law (Public Law 100-357)<br />
Coil - Windings of copper or aluminum wire surrounding a core in<br />
ballast.<br />
Conformal Coating - Material that surrounds and adheres to components<br />
and protects them.<br />
Constant Wattage Autotransformer (CWA) - An HID ballast in<br />
which the primary and secondary coils are electrically connected.<br />
Core - Component of electromagnetic ballast that is surrounded by<br />
the coil and comprised of steel laminations or solid ferrite material.<br />
Core & Coil Ballast - Another term for electromagnetic ballast.<br />
Crest Factor - Ratio of peak lamp current to RMS (average) lamp<br />
current.<br />
CSA E - Marking on ballast that shows compliance with Canadian<br />
Ballast Energy Law.<br />
Cycling - See 'Ballast Cycling'<br />
DC forward current - Continuous direct current applied which is<br />
constant over time.<br />
Decibel (dB) - Unit of measurement of the volume of sounds<br />
Die - Chip: heart of the LED<br />
Digital Addressable Lighting Interface (DALI) - An industry<br />
standard digital protocol that allows components from different<br />
manufacturers (ballasts, sensors, controllers, etc.) to be mixed<br />
together seamlessly into complete systems.<br />
Diode - A two-electrode device with an anode and a cathode that<br />
passes current in only one direction. It may be designed as an electron<br />
tube or as a semiconductor device.<br />
Direct Current (DC) - An electrical current flowing steadily in one<br />
direction only.<br />
Discharge Lamp - A light producing device that depends on an electric<br />
arc, rather than a filament, to create illumination.<br />
Driver - <strong>Electronic</strong>s used to power illumination sources. Ballast.<br />
Efficacy - See 'System Efficacy'<br />
Electrode - See 'Filament'<br />
Electromagnetic Ballast - A low frequency (50 - 60 Hz.) ballast that<br />
uses a "Core & Coil" assembly to transform electrical energy (voltage<br />
and current) to start and operate fluorescent and high intensity<br />
discharge (HID) lamps.<br />
Electromagnetic Interference(EMI) - <strong>Electric</strong>al interference (noise)<br />
generated by electrical and electronic devices. Levels<br />
generated by high frequency electronic devices are subject to<br />
regulation by the Federal Communications Commission (FCC). Two<br />
classifications exist Non-Consumer (also referred to as Class A or<br />
Commercial) and Consumer (also referred to as Class B or<br />
Residential).<br />
<strong>Electronic</strong> Ballast - A ballast that, with the aid of electronic<br />
components converts 60 Hz. input voltage and current to high<br />
frequency (20 kHz to 60 kHz.) to operate fluorescent and high intensity<br />
discharge (HID) lamps.<br />
<strong>Electronic</strong> Component - A device or part employed in an electronic<br />
circuit to obtain some desired electronic action.<br />
Energy - Work done by an electrical system measured in watts.<br />
EOL Protection Circuit - For all T5 and smaller lamps, operating<br />
parameters within the ballast that, when exceeded, will shutdown<br />
the ballast<br />
ETL - Independent electrical testing laboratory, which performs ballast<br />
testing.<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-1
INDUSTRY TERMS<br />
REFERENCE<br />
MATERIALS<br />
Federal Communication Commission (FCC) - The U.S. federal agency<br />
that is charged with regulating electrical interference emissions of the<br />
electromagnetic spectrum. The regulation entitled, "Part 18" deals<br />
with electromagnetic interference (EMI) from all lighting devices<br />
operating at frequencies higher than 9 kilohertz (kHz).<br />
Feedback Signal - A feedback signal, or control signal, regulates<br />
power through the LED driver to produce various effects in LEDs.<br />
Filament - Coated coil of special wire that emits electrons or light<br />
when heated.<br />
Filament Voltage - Voltage applied to heat the lamp filament coil.<br />
Fluorescent Lamp - Gas filled lamp in which light is produced by the<br />
interaction of an arc with phosphors lining the lamp's glass tube.<br />
Forward Current - Current through a diode in the direction of its<br />
greatest conduction.<br />
Forward Voltage (VF) - The voltage across a diode for a given forward<br />
current.<br />
Frequency - Rate of alteration in an AC current. Expressed in cycles<br />
per second or Hertz (Hz).<br />
Fundamental Frequency - Lowest frequency in a complex waveform.<br />
Also known as first harmonic<br />
Harmonic Distortion - A measurement of the magnitude of voltage<br />
and current harmonics as compared with the amplitude of the fundamental<br />
frequency. Harmonic distortion can be generated by a<br />
load and fed back into the AC mains, causing distortion of the sinusoidal<br />
waveform.<br />
Harmonics - Refers to components of the overall frequency, an integral<br />
multiple of the fundamental sinewave frequency.<br />
Hertz (Hz) - Unit used to measure frequency (cycles per second) of<br />
alternating current or voltage.<br />
High Frequency <strong>Electronic</strong> Ballast - In this book, refers to the operation<br />
of electronic ballasts as frequencies > 20,000 Hertz (20 kHz)<br />
High Intensity Discharge (HID) Lamp - A discharge lamp containing<br />
an arc tube in which the active elements within (mercury, sodium,<br />
etc.) becomes vaporized (a gaseous state) within the electric arc<br />
stream to produce light.<br />
High Light Output - Ballast with a nominal ballast factor of 1.18<br />
High Power Factor Ballast - A ballast in which the power factor is<br />
greater than 0.9 (90%). These ballasts require less line current than<br />
normal power factor ballast.<br />
High Reactance Autotransformer Ballast (HX) - HID ballast used<br />
when the input voltage does not meet the starting voltage requirement<br />
for a lamp. The ballast will transform the input voltage to the<br />
required level.<br />
Hot Restart Time - The time it takes a HID lamp to restart and reach<br />
90% of its light output after going from on to off to on. Typical<br />
restart times are 1 to 2 minutes for HPS and 5 to 20<br />
minutes for Metal Halide.<br />
IEC (International Electrotechnical Commission) - Organization<br />
made up of national committees from over 60 countries that sets<br />
international electrical and electronics standards<br />
IEEE (Institute of electrical and <strong>Electronic</strong>s Engineers)-<br />
Organization of engineers that establishes standards for electrical<br />
and electronics industries.<br />
Ignitor (Starter) - A device used within the ballast circuit to<br />
generate high voltage electrical pulses needed to start high<br />
pressure sodium and some metal halide lamps<br />
Illuminating Engineering Society (IES) - Recognized technical<br />
authority on the advancement of the art and science of illumination<br />
and its dissemination.<br />
InGaN - The preferred LED (Light Emitting Diode) semiconductor<br />
technology containing Indium, Gallium, and Nitrogen to produce<br />
green, blue and white-colored LED light sources.<br />
Input Power - See Input Watts<br />
Input Voltage - Voltage, provided by a power line or power<br />
supply, to the ballast or driver.<br />
Input Watts - Total power input to the ballast that includes lamp<br />
watts and ballast losses.<br />
Inrush Current - Initial surge of current when an electrical device is<br />
turned on.<br />
Instant Start Ballast - Electromagnetic or electronic lighting<br />
circuit without lamp filament heating that produces instant light.<br />
IntelliVolt - Multi-voltage feature of <strong>Advance</strong> electronic ballasts that<br />
allow the ballast to operate from a nominal input voltage range of<br />
120 - 277V at nominal frequencies of 50 or 60 Hz.<br />
Kilohertz (kHz) - One thousand Hertz (cycles per second).<br />
Laminations - Layers of steel, making up the ballast "core" that is<br />
surrounded by the coils in a core & coil ballast.<br />
Lamp - The lighting industry term for light bulb. It refers to the complete<br />
assembly including the internal parts as well as the outer bulb<br />
or tube and base(s).<br />
Lamp Current - The current delivered to the lamp by the ballast to<br />
generate light.<br />
Lamp Current Crest Factor - See "Crest Factor."<br />
Lamp Watts (Rated) - The power consumed by the lamp to generate<br />
light.<br />
Lead-Lag Slimline Ballast - Ballast that operate fluorescent lamps<br />
independently of one another. Can start lamps at 0°F.<br />
LED Driver - See 'Driver'<br />
Light - Radiant energy that can be sensed or seen by the human eye.<br />
Visible light is measured in lumens.<br />
Light Emitting Diode (LED) - A solid-state semiconductor device<br />
that converts electrical energy directly into light. On its most basic<br />
level, the semiconductor is comprised of two regions. The<br />
p-region contains positive electrical charges while the n-region contains<br />
negative electrical charges. When voltage is applied and current<br />
begins to flow, the electrons move across the n region into the<br />
p region. The process of an electron moving through the p-n junction<br />
releases energy. The dispersion of this energy produces photons<br />
with visible wavelengths.<br />
Line Current - See Ampere<br />
Low Power Factor - See 'Normal Power Factor'<br />
Low Voltage Control - DC voltage used for signaling purposes<br />
Low Watt - Ballast with a nominal ballast factor of 0.78 or less<br />
Lumens - Measurement of light emitted by a lighted lamp.<br />
Luminaire - A complete lighting fixture consisting of a lamp (or<br />
lamps), ballast(or ballasts) as required together with the parts<br />
designed to distribute the light, position and protect the lamp, and<br />
connect them to the incoming power.<br />
National <strong>Electric</strong> Code (NEC) - A nationally accepted electrical<br />
installation code developed by the National Fire Protection<br />
Association to reduce the risk of fire.<br />
National <strong>Electric</strong>al Manufacturers Association (NEMA) - U.S.<br />
based association that sets many common standards used in electrical<br />
products<br />
NOM (Normas Oficial Mexicana) - Laboratory that sets safety standards<br />
for building materials, electrical appliances and other products<br />
for Mexico.<br />
Normal Light Output - Ballast with a nominal ballast factor of 0.88<br />
for most T8 ballasts, and 1.00 for most T5 and dimming ballasts.<br />
Normal Power Factor - Ballast in which the power factor is less than<br />
0.80 (80%). These ballasts require about twice the line current of<br />
high power factor ballasts.<br />
Open Circuit Voltage [OCV] - Voltage, as measured at the lamp<br />
socket (HID or CFL) or across the lamp holders (fluorescent) when<br />
the lamp is not present, generated by the ballast needed to start a<br />
lamp when power is turned on.<br />
Operating Position or Burn Position - The orientation of an HID<br />
lamp in a lighting fixture such as base up, base down, horizontal, or<br />
universal.<br />
8-2<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
INDUSTRY TERMS<br />
Packaged LED - Consists of the die, a lead frame, which houses the<br />
die, the encapsulation epoxy that protectively surrounds the die, and<br />
also disperses the light.<br />
Parallel (LED) - <strong>Electric</strong>al condition where LEDs operate under the<br />
same voltage being provided by a driver.<br />
Parallel Circuit - Ballast circuit in which the lamps connected to<br />
one ballast operate independently of one another - if one lamp fails,<br />
the rest remain lit.<br />
PCB (Polychlorinated Biphenyls) - Chemical pollutant used in<br />
capacitors outlawed by the EPA in 1978. Ballast industry transitioned<br />
to non-PCB capacitors during 1979.<br />
Potting - Compound used to completely surround and cover components<br />
of some magnetic and electronic ballasts in order to protect<br />
components, dampen sound, and dissipate heat.<br />
Power - The amount of energy consumed or needed by a device<br />
(ballast, lamp, or ballast plus lamp) to perform its function. Power<br />
is measured in watts.<br />
Power Factor (PF) - A measurement of how efficiently an electrical<br />
device uses power supplied by the power line. PF = Watts / (Volts<br />
x Amps).<br />
Power Factor Corrected (PFC) - Ballast with a power factor from<br />
0.80 to 0.89<br />
Powerline Control - Method of dimming control where the phase of<br />
the sine wave is 'chopped' to dim the lamps.<br />
Preheat Ballast - Electromagnetic ballast that requires a separate<br />
starter in order to ignite the lamp<br />
Probe Start - Method of starting mercury vapor and specific metal<br />
halide lamps in which an additional electrode at one end of the arc<br />
tube assists in lamp starting.<br />
Programmed Start Ballast - An electronic lighting circuit similar to<br />
rapid start that provides precise heating of the lamp filaments and<br />
tightly controlling the preheat duration before applying starting voltage<br />
to ignite the lamp.<br />
Pulse Start - Method of starting high pressure sodium and specific<br />
metal halide lamps in which a high voltage starting pulse starts the<br />
lamps<br />
Quadri-Volt (Quad-Tap) - Feature within a ballast which gives you a<br />
choice of 4 different input voltages<br />
Rank - See 'Bin'<br />
Rapid Start Ballast - Electromagnetic or electronic ballast that provides<br />
both filament heating and starting voltage to the lamp at the<br />
same time in order to ignite the lamp.<br />
Reference Ballast (standard reactor) - Laboratory device used to<br />
provide ANSI specified measurements of initial and mean lamp<br />
lumens.<br />
Regulation, Lamp Wattage - The measure of the ability of a ballast<br />
or ballast circuit type to control (regulate) a lamp's operating<br />
wattage as the input voltage varies from nominal. It is the ratio of<br />
the percent change in line voltage (input voltage) and the resultant<br />
percent change in lamp wattage<br />
Reverse Current - Current flowing through a diode in the direction<br />
opposite to the direction of maximum conduction<br />
Reverse Voltage - Volatge across the diode for a given reverse current.<br />
RFI (Radio Frequency Interference) - Form of electromagnetic<br />
interference.<br />
Series (LED) - <strong>Electric</strong>al condition where LEDS operate under the<br />
same current being provided by a driver.<br />
Series Circuit - Ballast circuit in which the lamps connected to one<br />
ballast operate as a group. If one lamp fails or is removed, then all<br />
lamps in the circuit turn off<br />
Series-Sequence Slimline Ballast - <strong>Ballasts</strong> that operate with<br />
lamps starting in sequence.<br />
Series-Parallel Circuit - Ballast circuit in which the lamps connected<br />
to one ballast operate both as a group and independently. If one<br />
lamp fails or is removed in the series connected section, then all<br />
lamps in that section will turn off, but the lamps in the parallel circuit<br />
remain on.<br />
Sine Wave - A mathematical function used to represent voltage and<br />
current.<br />
Sound Rating - Classification given to a ballast based upon ballast<br />
noise.<br />
Starting Temperature - The minimum ambient temperature at<br />
which the lamp will start. Light output may be affected due to lamp<br />
characteristics.<br />
Striation - Spiraling or swirling of fluorescent lamps at initial turn<br />
on or energy-saving lamps at low temperature or low current.<br />
System Efficacy - Overall efficiency of the lamp/ballast system.<br />
System efficacy = total lamp lumens/system wattage<br />
Thermal Protector - A self-resetting switch that disconnects power<br />
to the ballast if internal temperatures rise above the trip point (typically<br />
105°C)<br />
Third Harmonic - Third multiple of the fundamental frequency that<br />
will add in the neutral wire of a three phase, 4 wire, Wye system and<br />
will cause over heating of the neutral wire should it exceed 33 1/3<br />
percent.<br />
Three-Phase, Four-Wire Wye - Most popular electrical wiring system<br />
used today for commercial building<br />
Total Harmonic Current (THC) - The combined effect of all of the<br />
harmonic distortion on the AC waveform produced by a ballast or<br />
other device. Excessive levels of THC can create large currents on<br />
the neutral line of a 3 phase 4 wire wye power system. See<br />
Harmonic Distortion.<br />
Total Harmonic Distortion (THD) - Total Harmonic Current (THC)<br />
expressed as a percentage.<br />
Transients - High voltage and resultant high current surges through<br />
an electrical system caused by lightning strikes to nearby transformers,<br />
overhead lines or the ground. May also be caused by<br />
switching of large motors or other electrical loads, as well as by<br />
short circuits or utility system switching. Can lead to premature failure<br />
of ballasts or other electrical devices.<br />
Trigger Start Ballast - Electromagnetic ballast that starts and operates<br />
preheat lamps similar to a rapid start lamp. No separate starter<br />
is needed to ignite the lamp.<br />
UL (Underwriters' Laboratories, Inc.) - A not for profit organization<br />
in the US that generates product performance and safety standards<br />
for electrical equipment, building materials, and other products. End<br />
use products such as lighting fixtures, fully encased ballasts, and<br />
home appliances are examples of UL Listed products and bear the<br />
UL logo. Components such as HID open core & coil ballasts, electrical<br />
insulating materials are UL Component Recognized products<br />
and bear the UL Component Recognition logo<br />
UR (UL Recognized) - A part or subassembly covered under UL's<br />
Recognition Service and intended for factory installation in UL certified<br />
products. They are intended for use as components of complete<br />
equipment submitted for investigation by UL.<br />
Voltage - A measurement of the electromotive force (electrical pressure)<br />
in an electrical circuit or device expressed in volts. Voltage can<br />
be thought of as being analogous to the pressure in a plumbing system.<br />
Voltage Sag - Drop in voltage levels of electrical distribution system<br />
that interferes with the operation of electrical and electronic equipment.<br />
Commonly called "Brownout". Results when demand for electricity<br />
exceeds capacity of the distribution system.<br />
Watt - The unit of measurement of electrical power. Watts = Volts x<br />
Amps x Power Factor<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-3
BALLAST SPECIFICATION<br />
MASTER SPEC. and CSI FORMAT<br />
BALLAST SPECIFICATION FOR LIGHTING<br />
SECTION I - FIXED LIGHT OUTPUT ELECTRONIC (FLUORESCENT)<br />
• Standard<br />
• Centium® Micro Can<br />
• Centium® T5<br />
• Centium® T8, T12 and FT5<br />
• Optanium® Dedicated Voltage<br />
• Optanium® 2.0 IntelliVolt®<br />
• Mark 5<br />
• SmartMate<br />
• Matchbox<br />
• AmbiStar<br />
• PowrKut®<br />
• PureVOLT<br />
SECTION II - CONTROLLABLE LIGHT OUTPUT ELECTRONIC (FLUORESCENT)<br />
• Mark 7 0-10V<br />
• Mark 10 Powerline<br />
•ROVR<br />
SECTION III - HID (INCLUDING METAL HALIDE, HIGH PRESSURE SODIUM, LOW<br />
PRESSURE SODUIM AND MERCURY VAPOR).<br />
SECTION IV - ELECTRONIC HID (METAL HALIDE)<br />
• e-Vision<br />
SECTION V - XITANIUM LED DRIVERS<br />
Corporate Offices<br />
(800) 322-2086<br />
Customer Support/Technical Service<br />
(800) 372-3331 • (+) 1 847 390-5000 (International)<br />
REFERENCE<br />
MATERIALS<br />
Visit our web site at www.advancetransformer.com<br />
8-4<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
BALLAST SPECIFICATION<br />
SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />
Ballast Specification for <strong>Electronic</strong> Fluorescent<br />
Standard<br />
<strong>Section</strong> I - Physical Characteristics<br />
1.1 Ballast shall be physically interchangeable with standard<br />
electromagnetic or standard electronic ballasts, where<br />
applicable.<br />
1.2 Ballast shall be provided with integral leads color-coded<br />
per ANSI C82.11.<br />
<strong>Section</strong> II - Performance Requirements<br />
2.1 Ballast shall be __________ (Instant or Rapid) Start.<br />
2.2 Ballast shall provide Independent Lamp Operation (ILO)<br />
for Instant Start ballasts allowing remaining lamp(s) to<br />
maintain full light output when one or more lamps fail.<br />
2.3 Ballast shall contain auto restart circuitry in order to<br />
restart lamps without resetting power.<br />
2.4 Ballast shall operate from 60 Hz input source of 120V,<br />
277V or 347V as applicable with sustained variations of<br />
+/- 10% (voltage and frequency) with no damage to the<br />
ballast.<br />
2.5 Ballast shall be high frequency electronic type and operate<br />
lamps at a frequency between 20 kHz and 30 kHz or above<br />
42 kHz to avoid interference with infrared devices and<br />
eliminate visible flicker.<br />
2.6 Ballast shall have a Power Factor greater than 0.98 for<br />
primary lamp.<br />
2.7 Ballast shall have a minimum ballast factor for primary<br />
lamp application as follows: 0.75 for Low Watt, 0.85 for<br />
Normal Light Output, and 1.20 for High Light.<br />
2.8 Ballast shall provide for a Lamp Current Crest Factor of<br />
1.7 or less in accordance with lamp manufacturer recommendations.<br />
2.9 Ballast input current shall have Total Harmonic Distortion<br />
(THD) of less than 20% for Standard models and THD of<br />
less than 10% for Centium models when operated at<br />
nominal line voltage with primary lamp.<br />
2.10 Ballast shall have a Class A sound rating for all 4-foot<br />
lamps and smaller.<br />
2.11 Ballast shall have a minimum starting temperature of<br />
_______ [-18C (0F) for standard T8 lamps, 10C (50F) for<br />
T8/HO, standard T12, Slimline T12 and Long Twin Tube<br />
lamps, 0C (32F) for Slimline T8, -29C (-20F) for T12/HO<br />
lamps,] for primary lamp application. Ballast shall have<br />
a minimum starting temperature of 60F (16C) for energysaving<br />
T8 and T12 lamps.<br />
2.12 Ballast shall tolerate sustained open circuit and short<br />
circuit output conditions without damage.<br />
<strong>Section</strong> III - Regulatory Requirements<br />
3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />
(PCB).<br />
3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />
Class P and Type 1 Outdoor; and Canadian Standards<br />
Association (CSA) certified where applicable.<br />
3.3 Ballast shall comply with ANSI C62.41 Category A for<br />
Transient protection.<br />
3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />
3.5 Ballast shall comply with the requirements of the Federal<br />
Communications Commission (FCC) rules and regulations,<br />
Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />
(conducted and radiated).<br />
<strong>Section</strong> IV - Other<br />
4.1 Ballast shall be manufactured in a factory certified to ISO<br />
9002 Quality System Standards.<br />
4.2 Ballast shall carry a five-year warranty from date of manu<br />
facture against defects in material or workmanship,<br />
including replacement, for operation at a maximum case<br />
temperature of 70C.<br />
4.3 Manufacturer shall have a fifteen-year history of producing<br />
electronic ballasts for the North American market.<br />
4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />
or approved equal.<br />
Note: Energy saving T8 lamps (25W, 28W or 30W) may<br />
experience lamp striations if operated on ballasts other than<br />
Optanium 2.0 (IOP) models. Remote or tandem wiring of energy<br />
saving T8 lamps (25W, 28W or 30W) is only recommended for<br />
Optanium 2.0 (IOP) models.<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-5
BALLAST SPECIFICATION<br />
SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />
Ballast Specification for <strong>Electronic</strong> Fluorescent<br />
Centium ® Micro Can<br />
<strong>Section</strong> I - Physical Characteristics<br />
1.1 Ballast shall be physically interchangeable with standard<br />
electromagnetic or standard electronic ballasts, where<br />
applicable.<br />
1.2 Ballast shall be provided with integral leads color-coded<br />
per ANSI C82.11.<br />
<strong>Section</strong> II - Performance Requirements<br />
2.1 Ballast shall be Instant Start.<br />
2.2 Ballast shall contain auto restart circuitry in order to restart<br />
lamps without resetting power.<br />
2.3 Ballast shall operate from 50/60 Hz input source of 120V or<br />
277V with sustained variations of +/- 10% (voltage and<br />
frequency) with no damage to the ballast. IntelliVolt models<br />
shall operate from 50/60 Hz input source of 120V through<br />
277V with sustained variations of +/- 10% (voltage and<br />
frequency) with no damage to the ballast.<br />
2.4 Ballast shall be high frequency electronic type and operate<br />
lamps at a frequency above 42 kHz to avoid interference<br />
with infrared devices and eliminate visible flicker.<br />
2.5 Ballast shall have a Power Factor greater than 0.98 for<br />
primary lamp.<br />
2.6 Ballast shall have a minimum ballast factor for primary lamp<br />
application as follows: 0.75 for Low Watt, 0.85 for Normal<br />
Light Output, and 1.20 for High Light.<br />
2.7 Ballast shall provide for a Lamp Current Crest Factor of 1.7 or<br />
less in accordance with lamp manufacturer recommendations.<br />
2.8 Ballast input current shall have Total Harmonic Distortion<br />
(THD) of less than 20% for Standard models and THD of<br />
less than 10% for Centium models when operated at<br />
nominal line voltage with primary lamp.<br />
2.9 Ballast shall have a Class A sound rating.<br />
2.10 Ballast shall have a minimum starting temperature of -18C<br />
(0F) for standard T8 lamps and 16C (60F) for energy-saving<br />
T8 lamps.<br />
2.11 Ballast shall provide Lamp EOL Protection Circuit.<br />
2.12 Ballast shall tolerate sustained open circuit and short circuit<br />
output conditions without damage.<br />
<strong>Section</strong> III - Regulatory Requirements<br />
3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB).<br />
3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />
Class P and Type 1 Outdoor; and Canadian Standards<br />
Association (CSA) certified where applicable.<br />
3.3 Ballast shall comply with ANSI C62.41 Category A for<br />
Transient protection.<br />
3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />
3.5 Ballast shall comply with the requirements of the Federal<br />
Communications Commission (FCC) rules and regulations,<br />
Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />
(conducted and radiated).<br />
<strong>Section</strong> IV - Other<br />
4.1 Ballast shall be manufactured in a factory certified to<br />
ISO 9002 Quality System Standards.<br />
4.2 Ballast shall carry a five-year warranty from date of<br />
manufacture against defects in material or workmanship,<br />
including replacement, for operation at a maximum case<br />
temperature of 70C.<br />
4.3 Manufacturer shall have a fifteen-year history of producing<br />
electronic ballasts for the North American market.<br />
4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />
or approved equal.<br />
Note: Energy saving T8 lamps (25W, 28W or 30W) may<br />
experience lamp striations if operated on ballasts other than<br />
Optanium 2.0 (IOP) models. Remote or tandem wiring of energy<br />
saving T8 lamps (25W, 28W or 30W) is only recommended for<br />
Optanium 2.0 (IOP) models.<br />
REFERENCE<br />
MATERIALS<br />
8-6<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
BALLAST SPECIFICATION<br />
SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />
Ballast Specification for <strong>Electronic</strong> Fluorescent<br />
Centium ® T5<br />
<strong>Section</strong> I - Physical Characteristics<br />
1.1 Ballast shall be physically interchangeable with standard<br />
electromagnetic or standard electronic ballasts, where<br />
applicable.<br />
1.2 Ballast shall be provided with integral leads or poke-in wire<br />
trap connectors color-coded per ANSI C82.11.<br />
<strong>Section</strong> II - Performance Requirements<br />
2.1 Ballast shall be Programmed Start.<br />
2.2 Ballast shall contain auto restart circuitry in order to restart<br />
lamps without resetting power.<br />
2.3 Ballast shall operate from 50/60 Hz input source of<br />
___________________ (120V through 277V or 347V<br />
through 480V) with sustained variations of +/- 10% (voltage<br />
and frequency) with no damage to the ballast.<br />
2.4 Ballast shall be high frequency electronic type and operate<br />
lamps at a frequency above 42 kHz to avoid interference<br />
with infrared devices and eliminate visible flicker.<br />
2.5 Ballast shall have a Power Factor greater than 0.98 for<br />
primary lamp.<br />
2.6 Ballast shall have a minimum ballast factor of 1.00 for<br />
primary lamp application.<br />
2.7 Ballast shall provide for a Lamp Current Crest Factor of 1.7 or<br />
less in accordance with lamp manufacturer recommendations.<br />
2.8 Ballast input current shall have Total Harmonic Distortion<br />
(THD) of less than 20% for Standard models and THD of<br />
less than 10% for Centium models when operated at<br />
nominal line voltage with primary lamp.<br />
2.9 Ballast shall have a Class A sound rating.<br />
2.10 Ballast shall have a minimum starting temperature of<br />
_______ {-18C (0F) or -28C (-20F)} for primary lamp.<br />
2.11 Ballast shall provide Lamp EOL Protection Circuit.<br />
2.12 Ballast shall tolerate sustained open circuit and short circuit<br />
output conditions without damage.<br />
2.13 Ballast shall have a hi-low switching option when operating<br />
(4) F54T5/HO lamps to allow switching from 4-2 lamps,<br />
3-2 lamps or 3-1 lamp.<br />
2.14 Four-lamp ballast shall have semi-independent lamp operation.<br />
<strong>Section</strong> III - Regulatory Requirements<br />
3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB).<br />
3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />
Class P and Type 1 Outdoor; and Canadian Standards<br />
Association (CSA) certified where applicable.<br />
3.3 Ballast shall comply with ANSI C62.41 Category A for<br />
Transient protection.<br />
3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />
3.5 Ballast shall comply with the requirements of the Federal<br />
Communications Commission (FCC) rules and regulations,<br />
Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />
(conducted and radiated).<br />
3.6 Ballast shall comply with UL Type CC rating.<br />
<strong>Section</strong> IV - Other<br />
4.1 Ballast shall be manufactured in a factory certified to<br />
ISO 9002 Quality System Standards.<br />
4.2 Ballast shall carry a five-year warranty from date of<br />
manufacture against defects in material or workmanship,<br />
including replacement, for operation at a maximum case<br />
temperature of 70C. <strong>Ballasts</strong> with a "90C" designation in<br />
their catalog number shall also carry a three-year warranty<br />
at a maximum case temperature of 90C.<br />
4.3 Manufacturer shall have a fifteen-year history of producing<br />
electronic ballasts for the North American market.<br />
4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />
or approved equal.<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-7
BALLAST SPECIFICATION<br />
SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />
Ballast Specification for <strong>Electronic</strong> Fluorescent<br />
Centium ® T8, T12 & FT5<br />
<strong>Section</strong> I - Physical Characteristics<br />
1.1 Ballast shall be physically interchangeable with standard<br />
electromagnetic or standard electronic ballasts, where<br />
applicable.<br />
1.2 Ballast shall be provided with integral leads color coded per<br />
ANSI C82.11.<br />
<strong>Section</strong> II - Performance Requirements<br />
2.1 Ballast shall be _________ (Instant, Rapid or Programmed)<br />
Start.<br />
2.2 Ballast shall provide Independent Lamp Operation (ILO) for<br />
Instant Start ballats allowing remaining lamp(s) to maintain<br />
full light output when one or more lamps fail.<br />
2.3 Ballast shall contain auto restart circuitry in order to restart<br />
lamps without resetting power (except T8/HO ballast).<br />
2.4 Ballast shall operate from 60 Hz input source of 120V, 277V<br />
or 347V as applicable with sustained variations of +/- 10%<br />
(voltage and frequency) with no damage to the ballast.<br />
IntelliVolt models shall operate from 50/60 Hz input source<br />
of 120V through 277V with sustained variations of +/- 10%<br />
(voltage and frequency) with no damage to the ballast.<br />
2.5 Ballast shall be high frequency electronic type and operate<br />
lamps at a frequency above 42 kHz ("GCN" models between<br />
20kHz and 30kHz) to avoid interference with infrared<br />
devices and eliminate visible flicker.<br />
2.6 Ballast shall have a Power Factor greater than 0.98 for primary<br />
lamp.<br />
2.7 Ballast shall have a minimum ballast factor for primary<br />
lamp application as follows: 0.75 for Low Watt, 0.85 for<br />
Normal Light Output, and 1.20 for High Light.<br />
2.8 Ballast shall provide for a Lamp Current Crest Factor of 1.7<br />
or less in accordance with lamp manufacturer recommendations.<br />
2.9 Ballast input current shall have Total Harmonic Distortion<br />
(THD) of less than 20% for Standard models and THD of<br />
less than 10% for Centium models when operated at nominal<br />
line voltage with primary lamp.<br />
2.10 Ballast shall have a Class A sound rating.<br />
2.11 Ballast shall have a minimum starting temperature of<br />
_______ [-18C (0F) for standard T8 and Long Twin Tube<br />
lamps, 10C (50F) for standard T12 lamps, 0C (32F) for<br />
Slimline T8 lamps and "GCN" models, -29C (-20F) for<br />
T8/HO lamps] for primary lamp application. Ballast shall<br />
have a minimum starting temperature of 16C (60F) for<br />
energy-saving T8 and T12 lamps.<br />
2.12 Ballast shall tolerate sustained open circuit and short<br />
circuit output conditions without damage.<br />
<strong>Section</strong> III - Regulatory Requirements<br />
3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />
(PCB).<br />
3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class<br />
P and Type 1 Outdoor; and Canadian Standards Association<br />
(CSA) certified where applicable.<br />
3.3 Ballast shall comply with ANSI C62.41 Category A for<br />
Transient protection.<br />
3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />
3.5 Ballast shall comply with the requirements of the Federal<br />
Communications Commission (FCC) rules and regulations,<br />
Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />
(conducted and radiated).<br />
<strong>Section</strong> IV - Other<br />
4.1 Ballast shall be manufactured in a factory certified to ISO<br />
9002 Quality System Standards.<br />
4.2 Ballast shall carry a five-year warranty from date of manufacture<br />
against defects in material or workmanship, including<br />
replacement, for operation at a maximum case temperature<br />
of 70C.<br />
4.3 Manufacturer shall have a fifteen year history of producing<br />
electronic ballasts for the North American market.<br />
4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />
or approved equal.<br />
Note: Energy saving T8 lamps (25W, 28W or 30W) may<br />
experience lamp striations if operated on ballasts other than<br />
Optanium 2.0 (IOP) models. Remote or tandem wiring of energy<br />
saving T8 lamps (25W, 28W or 30W) is only recommended for<br />
Optanium 2.0 (IOP) models.<br />
REFERENCE<br />
MATERIALS<br />
8-8<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
BALLAST SPECIFICATION<br />
SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />
Ballast Specification for <strong>Electronic</strong> Fluorescent<br />
Optanium ® Dedicated Voltage<br />
<strong>Section</strong> I - Physical Characteristics<br />
1.1 Ballast shall be physically interchangeable with standard<br />
electromagnetic or standard electronic ballasts, where<br />
applicable.<br />
1.2 Ballast shall be provided with integral leads color coded per<br />
ANSI C82.11.<br />
<strong>Section</strong> II - Performance Requirements<br />
2.1 Ballast shall be Instant Start.<br />
2.2 Ballast shall provide Independent Lamp Operation (ILO) for<br />
Instant Start ballats allowing remaining lamp(s) to maintain<br />
full light output when one or more lamps fail.<br />
2.3 Ballast shall contain auto restart circuitry in order to restart<br />
lamps without resetting power.<br />
2.4 Ballast shall operate from 60 Hz input source of 120V, 277V<br />
or 347V as applicable with sustained variations of +/- 10%<br />
(voltage and frequency) with no damage to the ballast.<br />
2.5 Ballast shall be high frequency electronic type and operate<br />
lamps at a frequency between 42 kHz and 52kHz to avoid<br />
interference with infrared devices, eliminate visible flicker<br />
avoid Article Surveillance Systems, such as anti-theft<br />
devices.<br />
2.6 Ballast shall have a Power Factor greater than 0.98 for<br />
primary lamp.<br />
2.7 Ballast shall have a minimum ballast factor for primary<br />
lamp application as follows: 0.75 for Low Watt, 0.85 for<br />
Normal Light Output, and 1.20 for High Light.<br />
2.8 Ballast shall provide for a Lamp Current Crest Factor of<br />
1.7 or less in accordance with lamp manufacturer<br />
recommendations.<br />
2.9 Ballast input current shall have Total Harmonic Distortion<br />
(THD) of less than 10% when operated at nominal line voltage<br />
with primary lamp.<br />
2.10 Ballast shall have a Class A sound rating for all 4-foot<br />
lamps and smaller<br />
2.11 Ballast shall have a minimum starting temperature of<br />
-18C (0F) for standard T8 lamps and 16C (60F) for<br />
energy-saving T8 lamps.<br />
2.12 Ballast shall tolerate sustained open circuit and short<br />
circuit output conditions without damage.<br />
<strong>Section</strong> III - Regulatory Requirements<br />
3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />
(PCB).<br />
3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />
Class P and Type 1 Outdoor; and Canadian Standards<br />
Association (CSA) certified, where applicable.<br />
3.3 Ballast shall comply with ANSI C62.41 Category A for<br />
Transient protection.<br />
3.4 Ballast shall comply with ANSI C82.11, where applicable.<br />
3.5 Ballast shall comply with the requirements of the Federal<br />
Communications Commission (FCC) rules and regulations,<br />
Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />
(conducted and radiated).<br />
<strong>Section</strong> IV - Other<br />
4.1 Ballast shall be manufactured in a factory certified to<br />
ISO 9002 Quality System Standards.<br />
4.2 Ballast shall carry a five-year warranty from date of<br />
manufacture against defects in material or workmanship,<br />
including replacement, for operation at a maximum case<br />
temperature of 70C. <strong>Ballasts</strong> with a “90C” designation in<br />
their catalog number shall also carra a three-year warranty<br />
at a maximum case temperature of 90C.<br />
4.3 Manufacturer shall have a fifteen year history of producing<br />
electronic ballasts for the North American market.<br />
4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />
or approved equal.<br />
Note: Energy saving T8 lamps (25W, 28W or 30W) may<br />
experience lamp striations if operated on ballasts other than<br />
Optanium 2.0 (IOP) models. Remote or tandem wiring of energy<br />
saving T8 lamps (25W, 28W or 30W) is only recommended for<br />
Optanium 2.0 (IOP) models.<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-9
BALLAST SPECIFICATION<br />
SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />
Ballast Specification for <strong>Electronic</strong> Fluorescent<br />
Optanium ® 2.0 IntelliVolt ®<br />
<strong>Section</strong> I - Physical Characteristics<br />
1.1 Ballast shall be physically interchangeable with standard<br />
electromagnetic or standard electronic ballasts, where<br />
applicable.<br />
1.2 Ballast shall be provided with integral leads color coded per<br />
ANSI C82.11.<br />
<strong>Section</strong> II - Performance Requirements<br />
2.1 Ballast shall be _________ (Instant or Programmed) Start.<br />
2.2 Ballast shall provide Independent Lamp Operation (ILO) for<br />
Instant Start ballats allowing remaining lamp(s) to maintain<br />
full light output when one or more lamps fail.<br />
2.3 Ballast shall contain auto restart circuitry in order to restart<br />
lamps without resetting power.<br />
2.4 Ballast shall operate from 50/60 Hz input source of 120V<br />
through 277V with sustained variations of +/- 10% (voltage<br />
and frequency) with no damage to the ballast.<br />
2.5 Ballast shall be high frequency electronic type and operate<br />
lamps at a frequency between 42 kHz and 52kHz to avoid<br />
interference with infrared devices, eliminate visible flicker<br />
and avoid Article Surveillance Systems, such as anti-theft<br />
devices.<br />
2.6 Ballast shall have a Power Factor greater than 0.98 for<br />
primary lamp.<br />
2.7 Ballast shall have a minimum ballast factor for primary<br />
lamp application as follows: 0.77 for Low Watt, 0.87<br />
for Normal Light Output, and 1.18 for High Light for Instant<br />
Start ballasts or 0.71 for Low Watt and 0.88 for Normal<br />
Light Output for Programmed Start ballasts.<br />
2.8 Ballast shall provide for a Lamp Current Crest Factor of<br />
1.7 or less in accordance with lamp manufacturer<br />
recommendations.<br />
2.9 Ballast input current shall have Total Harmonic Distortion<br />
(THD) of less than 10% when operated at nominal line voltage<br />
with primary lamp.<br />
2.10 Ballast shall have a Class A sound rating for all 4-foot<br />
lamps and smaller.<br />
2.11 Ballast shall have a minimum starting temperature of -29C<br />
(-20F) on Instant Start ballasts or -18C (0F) on<br />
Programmed Start ballasts for standard T8 lamps and 16C<br />
(60F) for energy-saving T8 lamps.<br />
2.12 Ballast shall tolerate sustained open circuit and short<br />
circuit output conditions without damage.<br />
2.13 Ballast shall contain an anti-striation circit to prevent<br />
striation on energy-saving T8 lamps.<br />
2.14 Programmed Start ballast shall provide lamp EOL<br />
protection circuitry.<br />
<strong>Section</strong> III - Regulatory Requirements<br />
3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />
(PCB).<br />
3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />
Class P and Type 1 Outdoor; and Canadian Standards<br />
Association (CSA) certified, where applicable.<br />
3.3 Ballast shall comply with ANSI C62.41 Category A for<br />
Transient protection.<br />
3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />
3.5 Ballast shall comply with the requirements of the Federal<br />
Communications Commission (FCC) rules and regulations,<br />
Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />
(conducted and radiated).<br />
3.6 Ballast shall comply with UL Type CC rating.<br />
3.7 Ballast shall meet NEMA/CEEE High Performance T8<br />
Lighting System Specifications.<br />
<strong>Section</strong> IV - Other<br />
4.1 Ballast shall be manufactured in a factory certified to<br />
ISO 9002 Quality System Standards.<br />
4.2 Ballast shall carry a five-year warranty from date of<br />
manufacture against defects in material or workmanship,<br />
including replacement, for operation at a maximum case<br />
temperature of 70C. <strong>Ballasts</strong> with a "90C" designation in<br />
their catalog number shall also carry a three-year warranty<br />
at a maximum case temperature of 90C.<br />
4.3 Manufacturer shall have a fifteen year history of producing<br />
electronic ballasts for the North American market.<br />
4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />
or approved equal.<br />
Note: Energy saving T8 lamps (25W, 28W or 30W) may<br />
experience lamp striations if operated on ballasts other than<br />
Optanium 2.0 (IOP) models. Remote or tandem wiring of energy<br />
saving T8 lamps (25W, 28W or 30W) is only recommended for<br />
Optanium 2.0 (IOP) models.<br />
REFERENCE<br />
MATERIALS<br />
8-10<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
BALLAST SPECIFICATION<br />
SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />
Ballast Specification for <strong>Electronic</strong> Fluorescent<br />
Mark 5<br />
<strong>Section</strong> I - Physical Characteristics<br />
1.1 Ballast shall be physically interchangeable with standard<br />
electromagnetic or standard electronic ballasts, where<br />
applicable.<br />
1.2 Ballast shall be provided with integral leads color coded per<br />
ANSI C82.11.<br />
<strong>Section</strong> II - Performance Requirements<br />
2.1 Ballast shall be Programmed Start.<br />
2.2 Ballast shall contain auto restart circuitry in order to restart<br />
lamps without resetting power.<br />
2.3 Ballast shall operate from 50/60 Hz input source of 120V<br />
through 277V with sustained variations from 90V - 305V<br />
with no damage to the ballast.<br />
2.4 Ballast shall be high frequency electronic type and operate<br />
lamps at a frequency above 42 kHz to avoid interference<br />
with infrared devices and eliminate visible flicker.<br />
2.5 Ballast shall have a Power Factor greater than 0.98 for<br />
primary lamp.<br />
2.6 Ballast shall have a minimum ballast factor for primary<br />
lamp application as follows: 0.75 for Low Watt, 0.85 for<br />
Normal Light Output, and 1.20 for High Light.<br />
2.7 Ballast shall provide for a Lamp Current Crest Factor of 1.5<br />
or less for primary lamp and 1.6 or less for all others.<br />
2.8 Ballast input current shall have Total Harmonic Distortion<br />
(THD) of less than 10% when operated at nominal line<br />
voltage with primary lamp.<br />
2.9 Ballast shall have a Class A sound rating.<br />
2.10 Ballast shall have a minimum starting temperature of<br />
-18C (0F) for standard T8 lamps and 16C (60F) for<br />
energy-saving T8 lamps.<br />
2.11 Ballast shall tolerate sustained open circuit and short<br />
circuit output conditions without damage.<br />
2.12 Ballast shall provide lamp EOL protection circuitry.<br />
<strong>Section</strong> III - Regulatory Requirements<br />
3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />
(PCB).<br />
3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />
Class P and Type 1 Outdoor; and Canadian Standards<br />
Association (CSA) certified where applicable.<br />
3.3 Ballast shall comply with ANSI C62.41 Category A for<br />
Transient protection.<br />
3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />
3.5 Ballast shall comply with the requirements of the Federal<br />
Communications Commission (FCC) rules and regulations,<br />
Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />
(conducted and radiated).<br />
<strong>Section</strong> IV - Other<br />
4.1 Ballast shall be manufactured in a factory certified to<br />
ISO 9002 Quality System Standards.<br />
4.2 Ballast shall carry a five-year warranty from date of<br />
manufacture against defects in material or workmanship,<br />
including replacement, for operation at a maximum case<br />
temperature of 70C.<br />
4.3 Manufacturer shall have a fifteen year history of producing<br />
electronic ballasts for the North American market.<br />
4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />
or approved equal.<br />
Note: Energy saving T8 lamps (25W, 28W or 30W) may<br />
experience lamp striations if operated on ballasts other than<br />
Optanium 2.0 (IOP) models. Remote or tandem wiring of energy<br />
saving T8 lamps (25W, 28W or 30W) is only recommended for<br />
Optanium 2.0 (IOP) models.<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-11
BALLAST SPECIFICATION<br />
SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />
Ballast Specification for <strong>Electronic</strong> Fluorescent<br />
SmartMate<br />
<strong>Section</strong> I - Physical Characteristics<br />
1.1 Ballast shall be physically interchangeable with standard<br />
electromagnetic or standard electronic ballasts, where<br />
applicable.<br />
1.2 Ballast shall be available in a plastic/metal can or all metal<br />
can construction to meet all plenum requirements.<br />
1.3 Ballast shall be provided with poke-in wire trap connectors<br />
color coded per ANSI C82.11.<br />
<strong>Section</strong> II - Performance Requirements<br />
2.1 Ballast shall be Programmed Start except for ballasts with<br />
-QS suffix, which shall be Rapid Start.<br />
2.2 Ballast shall contain auto restart circuitry in order to restart<br />
lamps without resetting power.<br />
2.3 Ballast shall operate from 50/60 Hz input source of 120V<br />
through 277V with sustained variations of +/- 10% (voltage<br />
and frequency) with no damage to the IntelliVolt ballast.<br />
2.4 Ballast shall be high frequency electronic type and operate<br />
lamps at a frequency above 42 kHz to avoid interference<br />
with infrared devices and eliminate visible flicker.<br />
2.5 Ballast shall have a Power Factor greater than 0.98 for<br />
primary lamp.<br />
2.6 Ballast shall have a minimum ballast factor of 1.00 for<br />
primary lamp application.<br />
2.7 Ballast shall provide for a Lamp Current Crest Factor of<br />
1.7 or less in accordance with lamp manufacturer<br />
recommendations.<br />
2.8 Ballast input current shall have Total Harmonic Distortion<br />
(THD) of less than 10% when operated at nominal line<br />
voltage with primary lamp.<br />
2.9 Ballast shall have a Class A sound rating.<br />
2.10 Ballast shall have a minimum starting temperature of -18C<br />
(0F) for primary lamp. <strong>Ballasts</strong> for PL-H lamps shall have<br />
a minimum starting temperature of -30C (-20F) for primary<br />
lamp.<br />
2.11 Ballast shall provide Lamp EOL Protection Circuit.<br />
2.12 Ballast shall tolerate sustained open circuit and short<br />
circuit output conditions without damage.<br />
<strong>Section</strong> III - Regulatory Requirements<br />
3.1 Ballast shall not contain any Polyclorinated Biphenyl (PCB)<br />
3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />
Class P and Type 1 Outdoor; and Canadian Standards<br />
Association (CSA) certified where applicable.<br />
3.3 Ballast shall be Underwriters Laboratories (UL) rated for<br />
use in air-handling spaces.<br />
3.4 Ballast shall comply with ANSI C62.41 Category A for<br />
Transient protection.<br />
3.5 Ballast shall comply with ANSI C82.11 where applicable.<br />
3.6 Ballast shall comply with the requirements of the Federal<br />
Communications Commission (FCC) rules and regulations,<br />
Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />
(conducted and radiated).<br />
<strong>Section</strong> IV - Other<br />
4.1 Ballast shall be manufactured in a factory certified to ISO<br />
9002 Quality System Standards.<br />
4.2 Ballast shall carry a five-year warranty from date<br />
of manufacture against defects in material or workmanship,<br />
including replacement, for operation at a maximum<br />
case temperature of 75C and three-years for a maximum<br />
case temperature of 85C (90C three-year warranty<br />
for ICF-1H120-M4-XX, ICF-2S42-90C-M2-XX and<br />
ICF-2S70-M4-XX models).<br />
4.3 Manufacturer shall have a fifteen year history of producing<br />
electronic ballasts for the North American market.<br />
4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />
or approved equal.<br />
REFERENCE<br />
MATERIALS<br />
8-12<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
BALLAST SPECIFICATION<br />
SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />
Ballast Specification for <strong>Electronic</strong> Fluorescent<br />
Matchbox<br />
<strong>Section</strong> I - Physical Characteristics<br />
1.1 Ballast shall be physically interchangeable with standard<br />
electromagnetic or standard electronic ballasts, where<br />
applicable.<br />
1.2 Ballast shall be provided with poke-in wire trap connectors<br />
color coded per ANSI C82.11.<br />
<strong>Section</strong> II - Performance Requirements<br />
2.1 Ballast shall be Instant Start.<br />
2.2 Ballast shall provide Independent Lamp Operation (ILO)<br />
allowing remaining lamp(s) to maintain full light output<br />
when one or more lamps fail.<br />
2.3 Ballast shall contain auto restart circuitry in order to restart<br />
lamps without resetting power.<br />
2.4 Ballast shall operate from 60 Hz input source of 120V with<br />
sustained variations of +/- 10% (voltage and frequency)<br />
with no damage to the ballast.<br />
2.5 Ballast shall be high frequency electronic type and operate<br />
lamps at a frequency above 42 kHz to avoid interference<br />
with infrared devices and eliminate visible flicker.<br />
2.6 Ballast shall have a Power Factor greater than 0.50 for<br />
primary lamp.<br />
2.7 Ballast shall provide for a Lamp Current Crest Factor of 1.7<br />
or less in accordance with lamp manufacturer recommendations.<br />
2.8 Ballast shall have a Class A sound rating.<br />
2.9 Ballast shall have a minimum starting temperature of -18C<br />
(0F) for primary lamp.<br />
2.10 Ballast shall provide Lamp EOL Protection Circuit.<br />
2.11 Ballast shall tolerate sustained open circuit and short<br />
circuit output conditions without damage.<br />
<strong>Section</strong> III - Regulatory Requirements<br />
3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />
(PCB).<br />
3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />
Class P, Type CC, and Type 1 Outdoor; and Canadian<br />
Standards Association (CSA) certified.<br />
3.3 Ballast shall be Underwriters Laboratories (UL) rated for<br />
use in air-handling spaces.<br />
3.4 Ballast shall comply with ANSI C62.41 Category A for<br />
Transient protection.<br />
3.5 Ballast shall comply with ANSI C82.11 where applicable.<br />
3.6 Ballast shall comply with the requirements of the Federal<br />
Communications Commission (FCC) rules and regulations,<br />
Title 47 CFR part 18, Consumer (Class B) for EMI/RFI (conducted<br />
and radiated).<br />
<strong>Section</strong> IV - Other<br />
4.1 Ballast shall be manufactured in a factory certified to<br />
ISO 9002 Quality System Standards.<br />
4.2 Ballast shall carry a two-year warranty from date of<br />
manufacture against defects in material or workmanship,<br />
including replacement, for operation at a maximum case<br />
temperature of 65C.<br />
4.3 Manufacturer shall have a fifteen year history of producing<br />
electronic ballasts for the North American market.<br />
4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />
or approved equal.<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-13
BALLAST SPECIFICATION<br />
SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />
Ballast Specification for <strong>Electronic</strong> Fluorescent<br />
AmbiStar<br />
<strong>Section</strong> I - Physical Characteristics<br />
1.1 Ballast shall be physically interchangeable with standard<br />
electromagnetic or standard electronic ballasts, where<br />
applicable.<br />
1.2 Ballast shall be provided with integral leads or poke-in wire<br />
trap connectors color coded per ANSI C82.11.<br />
<strong>Section</strong> II - Performance Requirements<br />
2.1 Ballast shall be ___________ (Instant, Rapid or Quick)<br />
Start.<br />
2.2 Ballast shall provide Independent Lamp Operation (ILO) for<br />
Instant Start ballasts allowing remaining lamp(s) to maintain<br />
full light output when one or more lamps fail.<br />
2.3 Ballast shall contain auto restart circuitry in order to restart<br />
lamps without resetting power.<br />
2.4 Ballast shall operate from 60 Hz input source of 120V with<br />
sustained variations of +/- 10% (voltage and frequency)<br />
with no damage to the ballast.<br />
2.5 Ballast shall be high frequency electronic type and operate<br />
lamps at a frequency above 42 kHz to avoid interference<br />
with infrared devices and eliminate visible flicker.<br />
2.6 Ballast shall have a Power Factor greater than 0.50 for primary<br />
lamp.<br />
2.7 Ballast shall provide for a Lamp Current Crest Factor of<br />
1.7 or less in accordance with lamp manufacturer<br />
recommendations.<br />
2.8 Ballast input current shall have Total Harmonic Distortion<br />
(THD) of less than 200% when operated at nominal line<br />
voltage with primary lamp.<br />
2.9 Ballast shall have a Class A sound rating.<br />
2.10 Ballast shall have a minimum starting temperature of<br />
_______ (-18C (0F) for standard T8 and CFL lamps, 10C<br />
(50F) for standard T12 lamps for primary lamp application<br />
and 16C (60F) for energy-saving T12 lamps.<br />
2.11 Ballast shall provide Lamp EOL Protection Circuit for CFL<br />
lamps.<br />
2.12 Ballast shall tolerate sustained open circuit and short circuit<br />
output conditions without damage.<br />
<strong>Section</strong> III - Regulatory Requirements<br />
3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />
(PCB).<br />
3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class<br />
P, and Type 1 Outdoor; and Canadian Standards Association<br />
(CSA) certified were applicable.<br />
3.3 Ballast shall comply with ANSI C62.41 Category A for<br />
Transient protection.<br />
3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />
3.5 Ballast shall comply with the requirements of the Federal<br />
Communications Commission (FCC) rules and regulations,<br />
Title 47 CFR part 18, Consumer (Class B) for EMI/RFI (conducted<br />
and radiated).<br />
<strong>Section</strong> IV - Other<br />
4.1 Ballast shall be manufactured in a factory certified to<br />
ISO 9002 Quality System Standards.<br />
4.2 Ballast shall carry a two-year warranty from date of<br />
manufacture against defects in material or workmanship,<br />
including replacement, for operation at a maximum case<br />
temperature of 65C.<br />
4.3 Manufacturer shall have a fifteen year history of producing<br />
electronic ballasts for the North American market.<br />
4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />
or approved equal.<br />
REFERENCE<br />
MATERIALS<br />
8-14<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
BALLAST SPECIFICATION<br />
SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />
Ballast Specification for <strong>Electronic</strong> Fluorescent<br />
PowrKut ®<br />
<strong>Section</strong> I - Physical Characteristics<br />
1.1 Ballast shall be physically interchangeable with standard<br />
electromagnetic or standard electronic ballasts, where<br />
applicable.<br />
1.2 Ballast shall be provided with integral leads color coded per<br />
ANSI C82.11.<br />
<strong>Section</strong> II - Performance Requirements<br />
2.1 Ballast shall be Rapid Start.<br />
2.2 Ballast shall contain auto restart circuitry in order to restart<br />
lamps without resetting power.<br />
2.3 Ballast shall operate from 60 Hz input source of 120V, 277V<br />
or 347V as applicable with sustained variations of +/- 10%<br />
(voltage and frequency) with no damage to the ballast.<br />
2.4 Ballast shall operate lamps at a frequency of 60 Hz.<br />
2.5 Ballast shall have a Power Factor greater than 0.90 for<br />
primary lamp.<br />
2.6 Ballast shall have a minimum ballast factor of 0.85 for T8 or<br />
0.80 for T12 primary lamp application.<br />
2.7 Ballast shall provide for a Lamp Current Crest Factor of<br />
1.7 or less in accordance with lamp manufacturer<br />
recommendations.<br />
2.8 Ballast input current shall have Total Harmonic Distortion<br />
(THD) of less than 20% when operated at nominal line<br />
voltage with primary lamp.<br />
2.9 Ballast shall have a Class A sound rating.<br />
2.10 Ballast shall have a minimum starting temperature of 10C<br />
(50F) for primary lamp and 16C (60F) for energy-saving<br />
lamps.<br />
2.11 Ballast shall tolerate sustained open circuit and short<br />
circuit output conditions without damage.<br />
<strong>Section</strong> III - Regulatory Requirements<br />
3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />
(PCB).<br />
3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />
Class P and Type 1 Outdoor; and Canadian Standards<br />
Association (CSA) certified where applicable.<br />
3.3 Ballast shall comply with ANSI C62.41 Category A for<br />
Transient protection.<br />
3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />
3.5 Ballast shall comply with the requirements of the Federal<br />
Communications Commission (FCC) rules and regulations,<br />
Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />
(conducted and radiated).<br />
<strong>Section</strong> IV - Other<br />
4.1 Ballast shall be manufactured in a factory certified to<br />
ISO 9002 Quality System Standards.<br />
4.2 Ballast shall carry a five-year warranty from date of<br />
manufacture against defects in material or workmanship,<br />
including replacement, for operation at a maximum case<br />
temperature of 90C.<br />
4.3 Manufacturer shall have a fifteen year history of producing<br />
electronic ballasts for the North American market.<br />
4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />
or approved equal.<br />
Note: Energy saving T8 lamps (25W, 28W or 30W) may<br />
experience lamp striations if operated on ballasts other than<br />
Optanium 2.0 (IOP) models. Remote or tandem wiring of energy<br />
saving T8 lamps (25W, 28W or 30W) is only recommended for<br />
Optanium 2.0 (IOP) models.<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-15
BALLAST SPECIFICATION<br />
SECTION I – Fixed Light Output <strong>Electronic</strong> (Fluorescent)<br />
Ballast Specification for <strong>Electronic</strong> Fluorescent<br />
PureVOLT<br />
<strong>Section</strong> I - Physical Characteristics<br />
1.1 Ballast shall be available in a plastic/metal can or all metal<br />
can construction to meet all plenum requirements.<br />
1.2 Ballast shall be provided with poke-in wire trap connectors<br />
color coded per ANSI C82.11.<br />
<strong>Section</strong> II - Performance Requirements<br />
2.1 Ballast shall be Programmed Start<br />
2.2 Ballast shall contain auto restart circuitry in order to restart<br />
lamps without resetting power.<br />
2.3 Ballast shall operate from 50/60 Hz input source of 120V<br />
through 277V with sustained variations of +/- 10% (voltage<br />
and frequency) with no damage to the IntelliVolt ballast.<br />
2.4 Ballast shall be high frequency electronic type and operate<br />
lamps at a frequency above 42 kHz to avoid interference<br />
with infrared devices and eliminate visible flicker.<br />
2.5 Ballast shall have a Power Factor greater than 0.96 for<br />
primary lamp.<br />
2.6 Ballast shall provide for a Lamp Current Crest Factor of<br />
1.7 or less in accordance with lamp manufacturer<br />
recommendations.<br />
2.7 Ballast input current shall have Total Harmonic Distortion<br />
(THD) of less than 10% when operated at nominal line voltage<br />
with primary lamp.<br />
2.8 Ballast shall have a Class A sound rating.<br />
2.9 Ballast shall have a minimum starting temperature of -18C<br />
(0F) for primary lamp.<br />
2.10 Ballast shall provide Lamp EOL Protection Circuit.<br />
2.11 Ballast shall tolerate sustained open circuit and short<br />
circuit output conditions without damage.<br />
<strong>Section</strong> III - Regulatory Requirements<br />
3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />
(PCB).<br />
3.2 Ballast shall be Underwriters Laboratories (UL) listed,<br />
Class P, and Type 1 Outdoor; and Canadian Standards<br />
Association (CSA) certified were applicable.<br />
3.3 Ballast shall be Underwriters Laboratories (UL) rated for<br />
use in air-handling spaces<br />
3.4 Ballast shall comply with ANSI C62.41 Category A for<br />
Transient protection.<br />
3.5 Ballast shall comply with ANSI C82.11 where applicable.<br />
3.6 Ballast shall comply with the requirements of the Federal<br />
Communications Commission (FCC) rules and regulations,<br />
Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />
(conducted and radiated).<br />
<strong>Section</strong> IV - Other<br />
4.1 Ballast shall be manufactured in a factory certified to<br />
ISO 9002 Quality System Standards.<br />
4.2 Ballast shall carry a five-year warranty from date of manufacture<br />
against defects in material or workmanship, including<br />
replacement, for operation at a maximum case temperature<br />
of 75C and three-years for a maximum case temperature<br />
of 85C (90C three-year warranty for IUV-2S60-M4-XX<br />
models).<br />
4.3 Manufacturer shall have a fifteen year history of producing<br />
electronic ballasts for the North American market.<br />
4.4 Ballast shall be <strong>Advance</strong> part # _____________<br />
or approved equal.<br />
REFERENCE<br />
MATERIALS<br />
8-16<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
BALLAST SPECIFICATION<br />
SECTION II – Controllable Light Output <strong>Electronic</strong> (Fluorescent)<br />
Ballast Specification for Controllable Light Output <strong>Electronic</strong> Fluorescent<br />
Mark 7 0-10V<br />
<strong>Section</strong> I - Physical Characteristics<br />
1.1 Ballast shall be physically interchangeable with standard<br />
electromagnetic or standard electronic ballasts, where<br />
applicable.<br />
1.2 Ballast shall be available in a plastic/metal can or all metal<br />
can construction to meet all plenum requirements.<br />
1.3 Ballast shall be provided with poke-in wire trap connectors<br />
or integral leads color coded per ANSI C82.11.<br />
<strong>Section</strong> II - Performance Requirements<br />
2.1 Ballast shall be Programmed Start.<br />
2.2 Ballast shall be provided with integral protection circuitry to<br />
withstand connection of low voltage control leads to mains<br />
power supply. In this event, ballast shall default to maximum<br />
light output.<br />
2.3 Ballast shall contain auto restart circuitry in order to restart<br />
lamps without resetting power.<br />
2.4 Ballast shall operate from 50/60 Hz input source of 120V or<br />
277V with sustained variations of +/- 10% (voltage and frequency)<br />
with no damage to the ballast. IntelliVolt models<br />
shall operate from 50/60 Hz input source of 120V through<br />
277V with sustained variations of +/- 10% (voltage and frequency)<br />
with no damage to the ballast.<br />
2.5 Ballast shall be high frequency electronic type and operate<br />
lamps at a frequency above 42 kHz to avoid interference<br />
with infrared devices and eliminate visible flicker.<br />
2.6 Ballast shall have a Power Factor greater than 0.98 at full<br />
light output and greater than 0.90 throughout the dimming<br />
range for primary lamp.<br />
2.7 Ballast shall have a minimum ballast factor of 1.00 at maximum<br />
light output and 0.03 at minimum light output for primary<br />
lamp application.<br />
2.8 Ballast shall provide for a Lamp Current Crest Factor of 1.7<br />
or less throughout the dimming range in accordance with<br />
lamp manufacturer recommendations.<br />
2.9 Ballast input current shall have Total Harmonic Distortion<br />
(THD) of less than 10% when operated at nominal line voltage<br />
with primary lamp.<br />
2.10 Ballast shall have a Class A sound rating.<br />
2.11 Ballast shall have a minimum starting temperature of 10C<br />
(50F) for primary lamp.<br />
2.12 Ballast shall provide Lamp EOL Protection Circuit for all<br />
T5, T5/HO, CFL lamps, and T8 lamps operating on 4-lamp<br />
ballast.<br />
2.13 Ballast shall control lamp light output from 100% - 3% relative<br />
light output for T8 and CFL lamps and 100% - 1%<br />
relative light output for T5/HO lamps.<br />
2.14 Ballast shall ignite the lamps at any light output setting<br />
without first going to another output setting.<br />
2.15 Ballast shall tolerate sustained open circuit and short circuit<br />
output conditions without damage.<br />
<strong>Section</strong> III - Regulatory Requirements<br />
3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />
(PCB).<br />
3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class<br />
P and Type 1 Outdoor; and Canadian Standards Association<br />
(CSA) certified where applicable.<br />
3.3 Ballast shall comply with ANSI C62.41 Category A for<br />
Transient protection.<br />
3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />
3.5 Ballast shall comply with the requirements of the Federal<br />
Communications Commission (FCC) rules and regulations,<br />
Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />
(conducted and radiated).<br />
<strong>Section</strong> IV - Other<br />
4.1 Ballast shall be manufactured in a factory certified to ISO<br />
9002 Quality System Standards.<br />
4.2 Ballast shall carry a five-year warranty from date of manufacture<br />
against defects in material or workmanship, including<br />
replacement, for operation at a maximum case temperature<br />
of 70C.<br />
4.3 Manufacturer shall have a fifteen year history of producing<br />
electronic ballasts for the North American market.<br />
4.4 Ballast shall be controlled by a Class 1 or Class 2 low voltage<br />
0-10VDC controller.<br />
4.5 Ballast shall be <strong>Advance</strong> part # _____________<br />
or approved equal.<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-17
BALLAST SPECIFICATION<br />
SECTION II – Controllable Light Output <strong>Electronic</strong> (Fluorescent)<br />
Ballast Specification for Controllable Light Output <strong>Electronic</strong> Fluorescent<br />
Mark 10 Powerline<br />
<strong>Section</strong> I - Physical Characteristics<br />
1.1 Ballast shall be physically interchangeable with standard<br />
electromagnetic or standard electronic ballasts, where<br />
applicable.<br />
1.2 Ballast shall be available in a plastic/metal can or all metal<br />
can construction to meet all plenum requirements.<br />
1.3 Ballast shall be provided with poke-in wire trap connectors<br />
or integral leads color coded per ANSI C82.11.<br />
<strong>Section</strong> II - Performance Requirements<br />
2.1 Ballast shall be Programmed Start.<br />
2.2 Ballast shall contain auto restart circuitry in order to restart<br />
lamps without resetting power.<br />
2.3 Ballast shall operate from 60 Hz input source of 120V, 277V<br />
or 347V as applicable with sustained variations of +/- 10%<br />
(voltage and frequency) with no damage to the ballast.<br />
2.4 Ballast shall be high frequency electronic type and operate<br />
lamps at a frequency above 42 kHz to avoid interference<br />
with infrared devices and eliminate visible flicker.<br />
2.5 Ballast shall have a Power Factor greater than 0.98 at full<br />
light output and greater than 0.90 throughout the dimming<br />
range for primary lamp.<br />
2.6 Ballast shall have a minimum ballast factor of 1.00 at maximum<br />
light output and 0.05 at minimum light output for primary<br />
lamp application.<br />
2.7 Ballast shall provide for a Lamp Current Crest Factor of 1.7<br />
or less throughout the dimming range in accordance with<br />
lamp manufacturer recommendations.<br />
2.8 Ballast input current shall have Total Harmonic Distortion<br />
(THD) of less than 10% at maximum light output when<br />
operated at nominal line voltage with primary lamp. Total<br />
Harmonic Current (THC) at minimum light output shall not<br />
exceed THC at maximum light output.<br />
2.9 Ballast shall have a Class A sound rating.<br />
2.10 Ballast shall have a minimum starting temperature of 10C<br />
(50F) for primary lamp.<br />
2.11 Ballast shall provide Lamp EOL Protection Circuit for all<br />
T5, T5/HO, and CFL lamps.<br />
2.12 Ballast shall control lamp light output from 100% - 5% relative<br />
light output for T8 and CFL lamps and 100% - 1%<br />
relative light output for T5/HO lamps.<br />
2.13 Ballast shall ignite the lamps at any light output setting<br />
without first going to another output setting.<br />
2.14 Ballast shall tolerate sustained open circuit and short circuit<br />
output conditions without damage.<br />
<strong>Section</strong> III - Regulatory Requirements<br />
3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />
(PCB).<br />
3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class<br />
P and Type 1 Outdoor; and Canadian Standards Association<br />
(CSA) certified where applicable.<br />
3.3 Ballast shall comply with ANSI C62.41 Category A for<br />
Transient protection.<br />
3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />
3.5 Ballast shall comply with the requirements of the Federal<br />
Communications Commission (FCC) rules and regulations,<br />
Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />
(conducted and radiated).<br />
<strong>Section</strong> IV - Other<br />
4.1 Ballast shall be manufactured in a factory certified to ISO<br />
9002 Quality System Standards.<br />
4.2 Ballast shall carry a five-year warranty from date of manufacture<br />
against defects in material or workmanship, including<br />
replacement, for operation at a maximum case temperature<br />
of 70C.<br />
4.3 Manufacturer shall have a fifteen year history of producing<br />
electronic ballasts for the North American market.<br />
4.4 Ballast shall be controlled by a compatible Mark 10<br />
Powerline two-wire dimmer.<br />
4.5 Ballast shall be <strong>Advance</strong> part # _____________<br />
or approved equal.<br />
REFERENCE<br />
MATERIALS<br />
8-18<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
BALLAST SPECIFICATION<br />
SECTION II – Controllable Light Output <strong>Electronic</strong> (Fluorescent)<br />
Ballast Specification for Controllable Light Output <strong>Electronic</strong> Fluorescent<br />
ROVR<br />
<strong>Section</strong> I - Physical Characteristics<br />
1.1 Ballast shall be physically interchangeable with standard<br />
electromagnetic or standard electronic ballasts, where<br />
applicable.<br />
1.2 Ballast shall be available in a plastic/metal can or all metal<br />
can construction to meet all plenum requirements.<br />
1.3 Ballast shall be provided with poke-in wire trap connectors<br />
or integral leads color coded per ANSI C82.11.<br />
<strong>Section</strong> II - Performance Requirements<br />
2.1 Ballast shall be Programmed Start.<br />
2.2 Ballast shall be provided with integral protection circuitry to<br />
withstand connection of low voltage control leads to mains<br />
power supply. In this event, ballast shall default to maximum<br />
light output.<br />
2.3 Ballast shall contain auto restart circuitry in order to restart<br />
lamps without resetting power.<br />
2.4 Ballast shall operate from 50/60 Hz input source of 120V or<br />
277V with sustained variations of +/- 10% (voltage and frequency)<br />
with no damage to the ballast. IntelliVolt models<br />
shall operate from 50/60 Hz input source of 120V through<br />
277V with sustained variations of +/- 10% (voltage and frequency)<br />
with no damage to the ballast.<br />
2.5 Ballast shall be high frequency electronic type and operate<br />
lamps at a frequency above 42 kHz to avoid interference<br />
with infrared devices and eliminate visible flicker.<br />
2.6 Ballast shall have a Power Factor greater than 0.98 at full<br />
light output and greater than 0.90 throughout the dimming<br />
range for primary lamp.<br />
2.7 Ballast shall have a minimum ballast factor of 1.00 at maximum<br />
light output and 0.03 at minimum light output for primary<br />
lamp application.<br />
2.8 Ballast shall provide for a Lamp Current Crest Factor of 1.7<br />
or less throughout the dimming range in accordance with<br />
lamp manufacturer recommendations.<br />
2.9 Ballast input current shall have Total Harmonic Distortion<br />
(THD) of less than 10% when operated at nominal line voltage<br />
with primary lamp.<br />
2.10 Ballast shall have a Class A sound rating.<br />
2.11 Ballast shall have a minimum starting temperature of 10C<br />
(50F) for primary lamp.<br />
2.12 Ballast shall provide Lamp EOL Protection Circuit for all<br />
T5, T5/HO, CFL lamps, and T8 lamps operating on 4-lamp<br />
ballast.<br />
2.13 Ballast shall control lamp light output from 100% - 3% relative<br />
light output for T8 and CFL lamps and 100% - 1%<br />
relative light output for T5/HO lamps.<br />
2.14 Ballast shall ignite the lamps at any light output setting<br />
without first going to another output setting.<br />
2.15 Ballast shall tolerate sustained open circuit and short circuit<br />
output conditions without damage.<br />
<strong>Section</strong> III - Regulatory Requirements<br />
3.1 Ballast shall not contain any Polychlorinated Biphenyl<br />
(PCB).<br />
3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class<br />
P and Type 1 Outdoor; and Canadian Standards Association<br />
(CSA) certified where applicable.<br />
3.3 Ballast shall comply with ANSI C62.41 Category A for<br />
Transient protection.<br />
3.4 Ballast shall comply with ANSI C82.11 where applicable.<br />
3.5 Ballast shall comply with the requirements of the Federal<br />
Communications Commission (FCC) rules and regulations,<br />
Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI<br />
(conducted and radiated).<br />
<strong>Section</strong> IV - Other<br />
4.1 Ballast shall be manufactured in a factory certified to ISO<br />
9002 Quality System Standards.<br />
4.2 Ballast shall carry a five-year warranty from date of manufacture<br />
against defects in material or workmanship, including<br />
replacement, for operation at a maximum case temperature<br />
of 70C.<br />
4.3 Manufacturer shall have a fifteen year history of producing<br />
electronic ballasts for the North American market.<br />
4.4 Ballast shall be controlled by a Class 1 or Class 2 low voltage<br />
DALI controller.<br />
4.5 Ballast shall be <strong>Advance</strong> part # _____________<br />
or approved equal.<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-19
BALLAST SPECIFICATION<br />
SECTION III – HID<br />
Ballast Specification for HID <strong>Ballasts</strong><br />
HID<br />
INCLUDING: Metal Halide, High Pressure Sodium, Low Pressure<br />
Sodium & Mercury Vapor<br />
Performance Requirements:<br />
1. <strong>Ballasts</strong> shall be designed in accordance with all applicable<br />
ANSI specifications including ANSI C82.4.<br />
2. The Core & Coil ballast shall be designed with class “H”<br />
(180°C) or higher insulation system and vacuum-pressure<br />
impregnated with a silica-filled polyester resin.<br />
3. All coils shall be precision wound.<br />
4. Core & Coil ballasts shall be designed to operate for 60,000<br />
hours of continuous operation at their maximum rated temperature.<br />
5. Core & Coil ballasts and starter combinations shall be<br />
designed to provide a reliable lamp starting down to -40°C<br />
for High Pressure Sodium and -30°C for Metal Halide at<br />
nominal line voltage of plus or minus 10%.<br />
6. All HID ballast shall have a nominal ballast factor of 1.0<br />
7. All HID ballasts shall contain no exposed live parts.<br />
Regulatory and Other Requirements<br />
1. Ballast shall be manufactured in an ISO 9002 and ISO 14001<br />
Certified Facility.<br />
2. Manufacturer shall provide written warranty against defects<br />
in workmanship, including replacement, for two years from<br />
date of manufacture.<br />
3. Manufacturer shall have been manufacturing HID ballasts for<br />
at least ten years.<br />
4. All HID ballasts shall be UL component recognized.<br />
5. All HID ballasts shall be CSA certified.<br />
6. Ballast must be <strong>Advance</strong> Transformer (or approved equal).<br />
CAPACITORS for HID<br />
1. All capacitors will be provided with a self-contained internal<br />
bleeder resistor where required according to UL1029.<br />
2. Oil-filled capacitors will be housed in aluminum or corrosionresistant<br />
steel cans and contain .25” quick disconnect terminals.<br />
3. Oil filled capacitors shall have a 90°C max case temperature<br />
rating.<br />
4. Dry film capacitors shall have a 105°C max. case temperature<br />
rating.<br />
5. All dry film capacitors shall be manufactured by the ballast<br />
manufacturer.<br />
6. All capacitors rated 400V or less shall be dry film type.<br />
7. All dry film capacitors shall have no exposed live parts.<br />
IGNITORS for HID<br />
1. All ignitors will be polyester resin-filled with either a plastic<br />
or aluminum external housing.<br />
2. The ignitor shall be so designed to provide six months of<br />
lamp open circuit operation without failure.<br />
3. All ignitors shall have a case rating temperature of 105°C.<br />
4. All ignitors shall be designed to withstand 10,000 hours of<br />
continuous pulsing.<br />
5. All ignitors shall have no exposed live parts.<br />
HID RETROFIT KITS<br />
1. All HID kits shall be precision wound to insure proper insulation.<br />
2. All HID kits shall be pre-wired with ignitors.<br />
3. HID core and coil shall be interchangeable with prior ballast<br />
or include mounting bracket to adapt ballast to intended fixture.<br />
4. All HID kits shall be supplied with pre-insulated input voltage<br />
leads.<br />
5. All HID kits are to be UL and CSA recognized following the<br />
guidelines found in UL 1029 and CAN/CSA-22.2 No. 74-92<br />
(part 2 and 3).<br />
8. The core & coil shall be designed with class “H” (180°C) or<br />
higher insulation system and vacuum-pressure impregnated<br />
with a silica-filled polyester resin.<br />
9. All capacitors rated 400V or less shall be dry film type rated<br />
105°C.<br />
10. There are to be no exposed live parts on the core & coil,<br />
ignitor, or dry capacitor.<br />
11. Must meet all ANSI Specifications for the specified lamp.<br />
12. Kit must include installation instructions and a 1-800# for<br />
field assistance.<br />
13. Ballast must be <strong>Advance</strong> Part # __________________<br />
(or approved equal).<br />
REFERENCE<br />
MATERIALS<br />
8-20<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
BALLAST SPECIFICATION<br />
SECTION IV – <strong>Electronic</strong> HID (Metal Halide)<br />
Ballast Specification for <strong>Electronic</strong> Metal Halide<br />
e-Vision ® <strong>Electronic</strong> Ballast Specifications<br />
<strong>Section</strong> I - Physical Characteristics<br />
1.0 The electronic ballast shall be furnished with integral, color-coded leads.<br />
<strong>Section</strong> II - Performance Requirements<br />
2.0 The electronic ballast shall be IntelliVolt ® and operate from a nominal<br />
line voltage range of 120-277 volts, +/-10%, 50/60 Hz.<br />
2.1 The electronic ballast input current shall have Total Harmonic<br />
Distortion (THD) of less than 15%.<br />
2.2 The electronic ballast shall have a Power Factor greater than 90%.<br />
2.3 The electronic ballast shall have a lamp end-of-life detection and<br />
shutdown circuit.<br />
2.4 The electronic ballast shall be Sound Rated A.<br />
2.5 The electronic ballast output frequency to the lamps shall be less<br />
than 200 Hz to prevent acoustic resonance inside the lamp arc tube<br />
and to minimize visible flicker.<br />
2.6 The electronic ballast shall provide a “Lamp Current Crest Factor” of<br />
less than 1.5.<br />
2.7 The electronic ballast shall be thermally protected to shut off when<br />
operating temperatures reach unacceptable levels.<br />
<strong>Section</strong> III - Regulatory Requirements<br />
3.0 The electronic ballast shall meet the requirements of the Federal<br />
Communications Commission rules and regulations, Title 47 CFR<br />
part 18, for Non-Consumer equipment.<br />
3.1 The electronic ballast shall be Underwriters Laboratories (UL) Listed<br />
(Class P) and CSA Certified where applicable.<br />
<strong>Section</strong> IV - Other<br />
4.0 The electronic ballast shall not contain Polychlorinated Biphenyl (PCB’s).<br />
4.1 The electronic ballast shall carry a three-year warranty from the date<br />
of manufacture for operation at a case temperature of 85ÞC or less.<br />
4.2 The manufacturer shall have a twenty-five year history of producing<br />
HID lamp ballasts for the North American market.<br />
4.3 The electronic ballast shall be produced in a factory certified to ISO<br />
9002 Quality System Standards<br />
DynaVision <strong>Electronic</strong> Ballast Specifications<br />
<strong>Section</strong> I – Physical Characteristics<br />
1.1 The electronic ballast shall be fully enclosed in an aluminum housing<br />
painted white.<br />
1.2 The aluminum housing shall include a divided wiring compartment<br />
to separate the power leads from the control leads. All leads to be<br />
color-coded.<br />
<strong>Section</strong> II – Performance Requirements<br />
2.1 The electronic ballast shall be multivoltage capable and operate from<br />
a line voltage range of 180 – 305 volts, 50/60 Hz.<br />
2.2 The electronic ballast shall incorporate a microprocessor controller<br />
to provide for optimum starting and operation of the HID lamp.<br />
2.3 The electronic ballast input current shall have Total Harmonic<br />
Distortion (THD) of less than 15% when operated at nominal line<br />
voltage (200V, 208V, 230V, 240V, 277V).<br />
2.4 The ballast shall incorporate a 0-10V dimming interface and<br />
control the dimming function such that the HID lamp is allowed to<br />
warm up for fifteen minutes at full power before the lamp will be<br />
allowed to dim, regardless of the level of the 0-10V signal.<br />
10V applied to the dimming control leads, shall result in full<br />
light output. 0V applied, or shorting the control leads together, shall<br />
result in dimming to 50% of nominal lamp power.<br />
2.5 The ballast shall include a 120V/250W auxiliary output for stand-by<br />
incandescent lighting that shall include an integral control to turn the<br />
auxiliary lamp on and off. The integral control shall include a timedelay<br />
feature to keep the auxiliary lamp on until the HID lamp reaches<br />
50% power.<br />
2.6 The electronic ballast shall have a Power Factor greater than 90%.<br />
2.7 The electronic ballast shall have a lamp end-of-life detection and<br />
shutdown circuit.<br />
2.8 The electronic ballast shall be Sound Rated A.<br />
2.9 The electronic ballast output frequency to the lamps shall be higher<br />
than 100 kHz to prevent acoustic resonance inside the lamp arc tube<br />
and to minimize visible flicker.<br />
2.10 The electronic ballast shall be thermally protected to shut off when<br />
operating temperatures reach unacceptable levels.<br />
<strong>Section</strong> III – Regulatory Requirements<br />
3.1 The electronic ballast shall meet the requirements of the Federal<br />
Communications Commission rules and regulations, Title 47 CFR<br />
part 18, for Non-Consumer equipment.<br />
3.2 The electronic ballast shall be Underwriters Laboratories (UL) Listed<br />
and CSA Certified where applicable.<br />
<strong>Section</strong> VI – Other<br />
4.1 The electronic ballast shall not contain Polychlorinated Biphenyl (PCB’s).<br />
4.2 The electronic ballast shall carry a three-year warranty from the date<br />
of manufacture for operation at an ambient temperature of 55° C or<br />
less and when operated as a stand alone product (i.e.remotely from<br />
a lighting fixture housing). When operated within a lighting fixture<br />
housing, the same three-year warranty shall apply for a maximum<br />
ballast case hot spot temperature of 76° C or less.<br />
4.3 The manufacturer shall have a twenty-five year history of producing<br />
HID lamp ballasts for the North American market.<br />
4.4 The electronic ballast shall be produced in a factory certified to<br />
ISO 9002 Quality System Standards.<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-21
BALLAST SPECIFICATION<br />
SECTION V – Xitanium LED Drivers<br />
Ballast Specification for Xitanium LED Drivers<br />
Xitanium<br />
<strong>Section</strong> I - Physical Characteristics<br />
1.1 Driver shall be available in a plastic/metal can or all metal<br />
can construction to meet all plenum requirements.<br />
1.2 Driver shall be provided with poke-in wire trap connectors<br />
or integral leads color coded per ANSI C82.11.<br />
<strong>Section</strong> II - Performance Requirements<br />
2.1 Driver shall operate from 60 Hz input source of 120V with<br />
sustained variations of +/- 10% (voltage and frequency)<br />
with no damage to the Driver.<br />
2.2 Driver output shall be regulated to +/- 5% across published<br />
load range.<br />
2.3 Driver shall operate LEDs at a frequency of 60 Hz.<br />
2.4 Driver shall have a Power Factor greater than 0.90 for<br />
primary application.<br />
2.5 Driver input current shall have Total Harmonic Distortion<br />
(THD) of less than 20%.<br />
2.6 Driver shall have a Class A sound rating.<br />
2.7 Driver shall have a minimum operating temperature of -40C<br />
(-40F).<br />
2.8 Driver shall tolerate sustained open circuit and short circuit<br />
output conditions without damage and without need for<br />
external fuses or trip devices.<br />
<strong>Section</strong> III - Regulatory Requirements<br />
3.1 Driver shall not contain any Polychlorinated Biphenyl<br />
(PCB).<br />
3.2 Driver shall be Underwriters Laboratories (UL) listed, Class<br />
2 Outdoor; and Canadian Standards Association (CSA) certified<br />
where applicable.<br />
3.3 Driver shall comply with ANSI C62.41 Category A for<br />
Transient protection.<br />
3.4 Driver shall comply with the requirements of the Federal<br />
Communications Commission (FCC) rules and regulations,<br />
Title 47 CFR part 15, Non-Consumer (Class A) for EMI/RFI<br />
(conducted and radiated).<br />
<strong>Section</strong> IV - Other<br />
4.1 Driver shall be manufactured in a factory certified to ISO<br />
9002 Quality System Standards.<br />
4.2 Driver shall carry a five-year warranty from date of manufacture<br />
against defects in material or workmanship, including<br />
replacement, for operation at a maximum case temperature<br />
of 90C.<br />
4.3 Manufacturer shall have a fifteen year history of producing<br />
electronic ballasts for the North American market.<br />
4.4 Dimmable drivers shall be controlled by a Class 2 low voltage<br />
0-10VDC controller.<br />
4.5 Driver shall be <strong>Advance</strong> Part # __________________<br />
or approved equal.<br />
REFERENCE<br />
MATERIALS<br />
8-22<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
INDEX<br />
Contents<br />
Ballast Catalog Number to Page Number<br />
Fluorescent ................................................................... 8-24 to 8-32<br />
HID................................................................................ 8-33 to 8-34<br />
Discontinued <strong>Ballasts</strong> - Replacements<br />
Electromagnetic Fluorescent....................................................... 8-35 to 8-36<br />
Fluorescent ............................................................................................. 8-37<br />
HID ............................................................................................. 8-38 to 8-41<br />
Lamp Index<br />
HID ............................................................................................ 8-42<br />
CFL ............................................................................................ 8-43<br />
Corporate Offices<br />
(800) 322-2086<br />
Customer Support/Technical Service<br />
(800) 372-3331 • (+) 1 847 390-5000 (International)<br />
Visit our web site at www.advancetransformer.com<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-23
INDEX – FLUORESCENT BALLASTS<br />
CATALOG NUMBER TO PAGE NUMBER LEAD LENGTHS AND SHIPPING DATA<br />
REFERENCE<br />
MATERIALS<br />
Catalog<br />
Number<br />
See<br />
Page<br />
No. Black White Blue Red Yellow<br />
Lead Lengths for ballasts purchased in bulk or mid-pack cartons<br />
Tolerance: +2", -1"<br />
A-175-S 6-16 10 71 47 10 40<br />
ADM-2E40-S-TP 6-16 41 41 23 23 10 58<br />
ADM-2E75-S-TP 6-16 70 70 46 46 10 58<br />
ASB-0412-12-BL-TP 3-40 18 18 33 33 51 1 12 ✓<br />
ASB-0620-24-BL-TP 3-40 24 24 75 46 75 46 46 1 12 ✓<br />
ASB-1224-24-BL-TP 3-40 24 24 74 32 70 52 78 1 14 ✓<br />
ASB-1240-46-BL-TP 3-40 24 24 50 80 70 50 50 50 50 1 21 ✓<br />
ASB-2040-24-BL-TP 3-40 24 24 80 80 72 54 72 1 21 ✓<br />
ASB-2432-34-BL-TP 3-40 24 24 72 72 72 72 72 1 18 ✓<br />
ASB-2448-46-BL-TP 3-40 24 24 50 50 70 50 50 50 50 1 21 ✓<br />
DIM-140-H-TP 3-12 35 35 20 20 20 10 37<br />
DIM-240-H-TP 3-12 18 34 34 20 20 34 18 6 38 ✓<br />
G-140-TP 3-7, 3-9, 3-10, 3-11 22 35 23 22 10 34<br />
G-1S32-TP 3-5, 3-6 18 35 23 18 10 35<br />
G-2E75-S-TP 3-22, 3-23 12 12 12 12 12 6 47<br />
G-2S110-TP 3-16, 3-17 22 22 46 46 70 6 70<br />
G-2S32-TP 3-5, 3-6 20 20 24 24 38 10 37<br />
G-2S40-TP 3-7, 3-9, 3-10, 3-11 12 12 12 12 12 10 34<br />
GCN-1S32 1-48, 1-54, 1-58 25 25 31 37 10 24<br />
GCN-2P32 1-48, 49, 54, 55, 58, 59 25 25 31 27 10 24<br />
GCN-2S32 1-49, 1-55, 1-59 22 22 26 26 36 10 24<br />
GCN-2TTP40-SC 1-35 25 25 30 30 20 28<br />
GCN-3S32 1-46, 1-50, 1-56, 1-60 22 22 26 36 26 36 10 28<br />
GEL2P32LW-RH-TP 1-45, 49, 54, 55, 59 25 25 31 37 10 24<br />
GEL-2P32-SC 1-45, 48, 49, 54, 55,58, 59 25 25 31 37 20 32<br />
GEL-2P59 1-64 25 25 31 37 10 28<br />
GEL-2S32-RH-TP 1-55, 1-59 22 22 26 26 36 10 24<br />
GEL-2S40-RH-TP 1-66, 1-67 22 22 26 26 36 10 24<br />
GEL-3P32-RH-TP 1-50, 1-56, 1-60, 1-63 25 25 31 37 10 28<br />
GEL-4P32-LW 1-47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 39 10 28<br />
GEL-4P32-RH-TP 1-47, 51, 57, 61, 63 25 25 31 31 39 10 28<br />
GK-132-TP 1-58 18 35 23 18 10 35<br />
GK-2S32-TP 1-59 22 22 26 26 36 10 38<br />
H-1B13-TP-BLS 3-34 7 7 7 35 32<br />
H-1B13-TP-W 3-34 15 15 15 36 36 ✓<br />
H-1B9-TP-BLS 3-33 7 7 7 35 28<br />
H-1B9-TP-W 3-33 15 15 15 36 29 ✓<br />
H-1Q18-TP-BLS 3-35 7 7 7 20 46<br />
H-1Q18-TP-W 3-35 15 15 15 20 46 ✓<br />
H-1Q22-TP-BLS 3-35 7 7 7 27 35<br />
H-1Q22-TP-W 3-35 15 15 15 24 31<br />
H-1Q26-TP-BLS 3-35, 3-36 7 7 7 20 46<br />
H-1Q26-TP-W 3-35, 3-36 15 15 15 20 46 ✓<br />
H-1Q28-TP-BLS 3-35 7 7 7 27 38<br />
H-1Q28-TP-W 3-35 15 15 15 24 34<br />
H-2B13-TP-BLS 3-34 7 7 7 20 36<br />
H-2B13-TP-W 3-34 15 15 15 20 36<br />
H-2B9-TP-BLS 3-33 7 7 7 20 32<br />
H-2B9-TP-W 3-33 15 15 15 20 32<br />
H-2Q18-TP-BLS 3-35 7 7 7 10 40<br />
H-2Q18-TP-W 3-35 15 15 15 10 40<br />
H-2Q26-TP-BLS 3-35 7 7 7 10 40<br />
H-2Q26-TP-W 3-35 15 15 15 10 40<br />
HCN-2S54-90C 1-34, 36, 37, 42, 43 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12 ✓<br />
HCN-4S54-90C-2LS-G 1-34, 36, 37, 43 32 32 54 51 60 42 60 42 6 18 ✓<br />
HF-B 136 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 6<br />
HF-B 158 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 6<br />
HF-B 236 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 7<br />
HF-B 258 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 7<br />
HF-P 1 14-35 TL5 HE 6-11 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 6<br />
HF-P 118 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 6<br />
*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />
*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />
** Also includes 36" violet & grey control leads.<br />
Blue/<br />
White<br />
Black/<br />
White<br />
Yellow/<br />
Blue<br />
Brown<br />
Red/<br />
White<br />
Orange Orange/<br />
Black<br />
Units<br />
Std.<br />
Ctn.<br />
Shipping Data<br />
Weight<br />
Std.<br />
Ctn. (lbs)<br />
Avail<br />
IC*<br />
Ctn.<br />
8-24<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
INDEX – FLUORESCENT BALLASTS<br />
CATALOG NUMBER TO PAGE NUMBER LEAD LENGTHS AND SHIPPING DATA<br />
Catalog<br />
Number<br />
See<br />
Page<br />
No. Black White Blue Red Yellow<br />
Lead Lengths for ballasts purchased in bulk or mid-pack cartons<br />
Tolerance: +2", -1"<br />
Blue/<br />
White<br />
Black/<br />
White<br />
Yellow/<br />
Blue<br />
Brown<br />
Red/<br />
White<br />
Orange Orange/<br />
Black<br />
Units<br />
Std.<br />
Ctn.<br />
Shipping Data<br />
Weight<br />
Std.<br />
Ctn. (lbs)<br />
HF-P 1 24-39 TL5 HO 6-11 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 6<br />
HF-P 136 PLL 6-10 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 6<br />
HF-P 136 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 6<br />
HF-P 140 PLL 6-10 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 6<br />
HF-P 1 54 TL5 HO 6-11 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 6<br />
HF-P 155 PLL 6-10 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 6<br />
HF-P 158 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 6<br />
HF-P 2 14-35 TL5 HE 6-11 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 7<br />
HF-P 218 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 7<br />
HF-P 2 24-39 TL5 HO 6-11 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 7<br />
HF-P 236 PLL 6-10 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 7<br />
HF-P 236 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 7<br />
HF-P 240 PLL 6-10 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 7<br />
HF-P 2 54 TL5 HO 6-11 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 7<br />
HF-P 255 PLL 6-10 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 7<br />
HF-P 258 TLD 6-12 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 7<br />
HM-140-TP 6-14 22 35 23 22 10 34<br />
HM-1P20-TP 3-27, 3-28 8 10 10 8 10 32 ✓<br />
HM-1P30-TP 3-8 18 26 17 18 10 34 ✓<br />
HM-2SP20-TP 3-27, 3-28 10 10 13 13 16 10 34 ✓<br />
ICF-1D38-H1-LD 1-39, 1-42 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
ICF-1H120-M4-BS 1-33 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 21<br />
ICF-1H120-M4-LD 1-33 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 26<br />
ICF-2S13-H1-LD 1-27, 1-29, 1-38 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
ICF-2S13-H1-LD-K 1-27, 1-29, 1-38 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8 ✓<br />
ICF-2S13-H1-LD-QS 1-27, 1-29 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
ICF-2S13-M1-BS 1-27, 1-29, 1-38 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 6.4<br />
ICF-2S13-M1-BS-QS 1-27, 1-29 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 6.4<br />
ICF-2S13-M1-LS 1-27, 1-29, 1-38 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
ICF-2S13-M1-LS-QS 1-27, 1-29 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
ICF-2S18-H1-LD 1-27, 1-30, 1-38 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
ICF-2S18-H1-LD-K 1-27, 1-30, 1-38 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8 ✓<br />
ICF-2S18-H1-LD-QS 1-27, 1-30 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
ICF-2S18-M1-BS 1-27, 1-30, 1-38 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 6.4<br />
ICF-2S18-M1-BS-QS 1-27, 1-30 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 6.4<br />
ICF-2S18-M1-LS 1-27, 1-30, 1-38 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
ICF-2S18-M1-LS-QS 1-27, 1-30 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
ICF-2S26-H1-LD 1-28, 31, 32, 34, 38 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
ICF-2S26-H1-LD-K 1-28, 31, 32, 34, 38 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8 ✓<br />
ICF-2S26-H1-LD-QS 1-28, 31, 32 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
ICF-2S26-M1-BS 1-28, 31, 32, 34, 38 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 6.4<br />
ICF-2S26-M1-BS-QS 1-28, 1-31, 1-32 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 6.4<br />
ICF-2S26-M1-LS 1-28, 31, 32, 34, 38 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
ICF-2S26-M1-LS-QS 1-28, 1-31, 1-32 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
ICF-2S42-M2-BS 1-28, 31, 32, 34, 35, 39, 42 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 13<br />
ICF-2S42-M2-LD 1-28, 31, 32, 34, 35, 39, 42 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16<br />
ICF-2S42-M2-LD-K 1-28, 31, 32, 34, 35, 39, 42 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16 ✓<br />
ICF-2S42-M2-LS 1-28, 31, 32, 34, 35, 39, 42 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16<br />
ICF-2S42-90C-M2-BS 1-28, 31, 32, 34, 35, 39, 42 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 13<br />
ICF-2S42-90C-M2-LD 1-28, 31, 32, 34, 35, 39, 42 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16<br />
ICF-2S42-90C-M2-LS 1-28, 31, 32, 34, 35, 39, 42 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16<br />
ICF-2S70-M4-BS 1-32 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 21<br />
ICF-2S70-M4-LD 1-32 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 26<br />
ICN-132-MC 1-41, 1-44, 1-54, 1-58 25 31 37 25 20 15 ✓<br />
ICN-1P32-LW-SC 1-44, 1-48, 1-54, 1-58 25 31 37 25 20 28 ✓<br />
ICN-1P32-SC 1-44, 1-48, 1-54, 1-58 25 31 37 25 20 28 ✓<br />
ICN-1S80 1-43, 6-6 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12<br />
ICN-2M32-MC 1-41, 45, 49, 55, 59 25 25 31 37 20 15 ✓<br />
ICN-2P32-LW-SC 1-44, 45, 48, 49, 54, 55, 59, 62 25 25 31 37 20 28 ✓<br />
ICN-2P32-SC 1-44, 45, 48, 49, 54, 55, 58, 59, 62 25 25 31 37 20 28 ✓<br />
ICN-2S24 1-34, 1-35, 1-42, 1-43 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12 ✓<br />
*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />
*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />
** Also includes 36" violet & grey control leads.<br />
Avail<br />
IC*<br />
Ctn.<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-25
INDEX – FLUORESCENT BALLASTS<br />
CATALOG NUMBER TO PAGE NUMBER LEAD LENGTHS AND SHIPPING DATA<br />
REFERENCE<br />
MATERIALS<br />
Catalog<br />
Number<br />
See<br />
Page<br />
No. Black White Blue Red Yellow<br />
Lead Lengths for ballasts purchased in bulk or mid-pack cartons<br />
Tolerance: +2", -1"<br />
Blue/<br />
White<br />
Black/<br />
White<br />
Yellow/<br />
Blue<br />
Brown<br />
Red/<br />
White<br />
Orange Orange/<br />
Black<br />
Units<br />
Std.<br />
Ctn.<br />
Shipping Data<br />
Weight<br />
Std.<br />
Ctn. (lbs)<br />
ICN-2S28 1-41 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12 ✓<br />
ICN-2S39 1-34, 1-35, 1-42, 1-43 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12 ✓<br />
ICN-2S54 1-34, 36, 37, 42, 43, 6-6 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12 ✓<br />
ICN-2S54-90C 1-34, 36, 37, 42, 43, 6-6 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12 ✓<br />
ICN-2S86 1-65 22 22 46 46 70 6 25 ✓<br />
ICN-3P32-LW-SC 1-45, 46, 49, 50, 55, 56, 59, 60, 62 25 25 31 37 20 28 ✓<br />
ICN-3P32-SC 1-45, 46, 49, 50, 55, 56, 59, 60, 62 25 25 31 37 20 28 ✓<br />
ICN-3S14-D 1-41 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12<br />
ICN-4P32-LW-SC 1-46, 47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 35 20 28 ✓<br />
ICN-4P32-SC 1-46, 47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 35 20 28 ✓<br />
ICN-4S54-90C-2LS 1-34, 36, 37, 43, 6-6 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 18<br />
ICN-4S54-90C-2LS-G 1-34, 36, 37, 43, 6-6 32 32 54 51 60 42 60 42 6 18 ✓<br />
IDA-132-SC 2-21 22 46 26 22 20 15<br />
IDA-154 2-19, 2-20 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12<br />
IDA-2S32-SC 2-21 22 22 26 26 46 20 21<br />
IDA-2S54 2-19, 2-20 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12<br />
IDA-3S32-G 2-21 22 22 28 54 28 54 6 18<br />
IDA-4S32 2-21 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12<br />
IDL-2S26-M5-BS 2-18 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 14<br />
IDL-2S26-M5-LD 2-18 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16<br />
IDL-2T42-M5-BS 2-18 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 14<br />
IDL-2T42-M5-LD 2-18 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16<br />
IEZ-124-D 2-8, 2-9 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12<br />
IEZ-2S24-D 2-8, 2-9 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12<br />
IIC-132-SC 1-44, 1-48, 1-54, 1-58 22 46 26 22 20 20 ✓<br />
IIC-2S32-SC 1-45, 1-49, 1-55, 1-59 22 22 26 26 46 20 20 ✓<br />
IIC-3S32-SC 1-46, 1-50, 1-56, 1-60 22 22 26 46 26 46 20 30 ✓<br />
IOP-1P32-HL-SC 1-44, 48, 52, 53, 54, 58 25 31 37 25 20 28 ✓<br />
IOP-1P32-LW-SC 1-44, 48, 52, 53, 54, 58 25 31 37 25 20 28 ✓<br />
IOP-1P32-SC 1-44, 48, 52, 53, 54, 58 25 31 37 25 20 28 ✓<br />
IOP-1S32-LW-SC 1-44, 48, 52, 53, 54, 58 36 36 26 25 20 20<br />
IOP-1S32-SC 1-44, 48, 52, 53, 54, 58 36 36 26 25 20 20<br />
IOP-2P32-HL-SC 1-44, 45, 48, 49, 52, 53, 54, 55, 58, 59, 62 25 25 31 37 20 28 ✓<br />
IOP-2P32-LW-SC 1-44, 45, 48, 49, 52, 53, 54, 55, 58, 59, 62 25 25 31 37 20 28 ✓<br />
IOP-2P32-SC 1-44, 45, 48, 49, 52, 53, 54, 55, 58, 59, 62 25 25 31 37 20 28 ✓<br />
IOP-2P59-SC 1-64 22 22 46 70 20 20 ✓<br />
IOP-2S28-115-SC-SD 2-3 (2) 22 22 26 26 36 20 20<br />
IOP-2S28-95-SC-SD 2-3 (2) 22 22 26 26 36 20 20<br />
IOP-2S32-LW-SC 1-44, 45, 48, 49, 52, 53, 54, 55, 58, 59, 62 25 25 31 37 20 20 ✓<br />
IOP-2S32-SC 1-44, 45, 48, 49, 52, 53, 54, 55, 58, 59, 62 25 25 31 37 20 20 ✓<br />
IOP-3P32-HL-90C-SC 1-45, 46, 49, 50, 52, 53, 55, 56, 59, 60, 62 25 25 31 37 20 32 ✓<br />
IOP-3P32-LW-SC 1-45, 46, 49, 50, 52, 53, 55, 56, 59, 60, 62 25 25 31 37 20 28 ✓<br />
IOP-3P32-SC 1-45, 46, 49, 50, 52, 53, 55, 56, 59, 60, 62 25 25 31 37 20 28 ✓<br />
IOP-3S32-LW-SC 1-46, 50, 52, 53, 56, 60 25 25 31 37 20 28 ✓<br />
IOP-3S32-SC 1-46, 50, 52, 53, 56, 60 25 25 31 37 20 28 ✓<br />
IOP-4P32-HL-90C-G 1-46, 47, 50, 51, 52, 53, 56, 57, 60, 61, 63 25 25 31 31 39 6 18 ✓<br />
IOP-4P32-LW-SC 1-46, 47, 50, 51, 52, 53, 56, 57, 60, 61, 63 25 25 31 31 39 20 28 ✓<br />
IOP-4P32-SC 1-46, 47, 50, 51, 52, 53, 56, 57, 60, 61, 63 25 25 31 31 39 20 28 ✓<br />
IOP-4S32-LW-SC 1-47, 51, 52, 53, 57, 61 25 25 31 31 39 20 28 ✓<br />
IOP-4S32-SC 1-47, 51, 52, 53, 57, 61 25 25 31 31 39 20 28 ✓<br />
IUV-2S18-H1-LD 6-5 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
IUV-2S36-M2-LD 6-5 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16<br />
IUV-2S60-M4-BS 6-5 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 21<br />
IUV-2S60-M4-LD 6-5 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 26<br />
IZT-132-SC ** 2-15, 2-16 22 46 26 22 20 15 ✓<br />
IZT-2S26-M5-BS 2-12 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 14<br />
IZT-2S26-M5-LD 2-12 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16<br />
IZT-2S32-SC ** 2-15, 2-16 22 22 26 26 46 20 21 ✓<br />
IZT-2T42-M5-BS 2-12 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 14<br />
IZT-2T42-M5-LD 2-12 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16<br />
IZT-2TTS40-SC ** 2-13 12 12 24 24 24 20 21<br />
*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />
*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />
** Also includes 36" violet & grey control leads.<br />
Avail<br />
IC*<br />
Ctn.<br />
8-26<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
INDEX – FLUORESCENT BALLASTS<br />
CATALOG NUMBER TO PAGE NUMBER LEAD LENGTHS AND SHIPPING DATA<br />
Catalog<br />
Number<br />
See<br />
Page<br />
No. Black White Blue Red Yellow<br />
Lead Lengths for ballasts purchased in bulk or mid-pack cartons<br />
Tolerance: +2", -1"<br />
Blue/<br />
White<br />
Black/<br />
White<br />
Yellow/<br />
Blue<br />
Brown<br />
Red/<br />
White<br />
Orange Orange/<br />
Black<br />
Units<br />
Std.<br />
Ctn.<br />
Shipping Data<br />
Weight<br />
Std.<br />
Ctn. (lbs)<br />
IZT-3S32-SC ** 2-15, 2-16 22 22 26 46 26 46 20 21 ✓<br />
IZT-4S32 2-15, 2-16 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12<br />
L-120F 3-25, 3-26 (2) 10 36 32 ✓<br />
L-140F-TP 3-25, 3-26, 3-29, 3-36 43 27 14 20 42 ✓<br />
L-1B13-TP-BLS 3-34 7 7 35 32<br />
L-1B13-TP-W 3-34 15 15 36 36<br />
L-1B9-TP-BLS 3-33 7 7 35 28<br />
L-1B9-TP-W 3-33 15 15 36 29 ✓<br />
L-1BC13-TP-BLS 3-34 7 7 27 41<br />
L-1BC13-TP-W 3-34 15 15 24 36<br />
L-1Q13-TP-W 3-24, 3-34 15 15 15 20 40 ✓<br />
L-1Q18-TP-BLS 3-35 7 7 7 20 40<br />
L-1Q18-TP-W 3-35 15 15 15 20 40 ✓<br />
L-1Q26-TP-BLS 3-35, 3-36 7 7 7 20 40<br />
L-1Q26-TP-W 3-35, 3-36 15 15 15 20 40 ✓<br />
L-220F 3-25, 3-26 10 12 20 36 ✓<br />
LC-13-TP 3-31 17 14 50 35<br />
LC-14-20-C 3-25, 3-26 14, 17 50 30 ✓<br />
LC-14-20-C-TP 3-29 17 14 50 35<br />
LC-25 3-26 7, 22 50 35 ✓<br />
LC-25-TP 3-32 7 22 50 35 ✓<br />
LC-4-9-C 3-24 (2) 10 50 30 ✓<br />
LC-4-9-C-TP 3-31 10 10 50 30<br />
LO-13-22 3-25, 3-26 (2) 15 72 43<br />
LO-13-22-TP 3-29, 3-31, 3-32 15 15 72 43<br />
LO-1Q22 3-32 (2) 15 72 43<br />
LO-1Q28-TP 3-32 15 15 20 26 ✓<br />
LOS-1Q28 3-32 (2) 15 72 58<br />
LPL-5-9 3-24 (2) 9 135 41<br />
LPL-5-9-TP 3-31 9 9 120 36<br />
LPL-7-9 3-24 (2) 9 150 45<br />
LQ-106F-TP 3-27 10 10 10 10 20 40 ✓<br />
LQ-206F-TP 3-27 10 10 10 10 10 20 40 ✓<br />
LS-113-TP 3-24 15 15 15 20 28 ✓<br />
LSX-113-TP 3-24 15 15 15 15 36 36<br />
LSX-213-TP 3-24 15 15 15 15 36 43 ✓<br />
LX-140-F-TP 3-25, 3-26, 3-29, 3-36 26 26 26 10 26 20 40 ✓<br />
MT-2S110-TP 6-15 18 18 46 46 70 18 6 60<br />
MTM-140-TP 6-14 18 18 35 23 28 10 40<br />
MTM-2S40-TP 6-14 18 18 24 24 36 18 10 40<br />
R-140-TP 3-7, 3-9, 3-10 12 12 12 12 10 36 ✓<br />
R-1BP27-TP 3-37 12 12 12 12 10 36<br />
R-1BP39-TP 3-37 12 12 12 12 10 36 ✓<br />
R-1BP40-TP 3-37 18 28 28 18 10 36 ✓<br />
R-1P32-TP 3-5, 3-6 18 36 23 18 10 37 ✓<br />
R-1P817-TP 3-5, 3-6, 3-37 18 17 17 18 10 36 ✓<br />
R-1P825-TP 3-5, 3-6 18 24 24 18 10 36<br />
R-1P840-TP 3-5 18 44 28 18 10 37<br />
R-1U40-TP 3-11 12 12 12 12 10 36 ✓<br />
R-2BP27-TP 3-37 12 12 24 24 24 10 37<br />
R-2BS39-TP 3-37 12 12 24 24 24 10 37 ✓<br />
R-2BS40-TP 3-37 20 20 24 24 36 10 37 ✓<br />
R-2E60-S-TP 3-23 12 12 12 12 6 49 ✓<br />
R-2E75-S-TP 3-22, 3-23, 6-16 12 12 12 12 6 49 ✓<br />
R-2P32-TP 3-5, 3-6 20 20 24 24 36 10 37 ✓<br />
R-2P817-TP 3-5, 3-6, 3-37 10 10 14 14 26 10 37 ✓<br />
R-2P825-TP 3-5, 3-6 12 12 20 20 32 10 37 ✓<br />
R-2P840-TP 3-5 20 20 28 28 44 10 37 ✓<br />
R-2S110-TP 3-16, 3-17 22 22 46 46 70 6 71 ✓<br />
R-2S34-TP 3-9, 3-10, 3-11 12 12 12 12 12 10 36 ✓<br />
R-2S40-TP 3-7, 9, 10, 11, 6-14 12 12 12 12 12 10 36 ✓<br />
*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />
*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />
** Also includes 36" violet & grey control leads.<br />
Avail<br />
IC*<br />
Ctn.<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-27
INDEX – FLUORESCENT BALLASTS<br />
CATALOG NUMBER TO PAGE NUMBER LEAD LENGTHS AND SHIPPING DATA<br />
REFERENCE<br />
MATERIALS<br />
Catalog<br />
Number<br />
See<br />
Page<br />
No. Black White Blue Red Yellow<br />
Lead Lengths for ballasts purchased in bulk or mid-pack cartons<br />
Tolerance: +2", -1"<br />
Blue/<br />
White<br />
Black/<br />
White<br />
Yellow/<br />
Blue<br />
Brown<br />
Red/<br />
White<br />
Orange Orange/<br />
Black<br />
Units<br />
Std.<br />
Ctn.<br />
Shipping Data<br />
Weight<br />
Std.<br />
Ctn. (lbs)<br />
R-2SP30-TP 3-8 18 18 17 17 26 10 37 ✓<br />
R-3S34-TP 3-9 20 20 24 36 24 36 10 37 ✓<br />
R-4S40-A-TP-AC 3-9, 3-10 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 1 7 ✓<br />
RC-2E75-S-TP 3-22, 3-23 12 12 12 12 6 49 ✓<br />
RC-2S102-FO 3-39 6.5 6.5 6.5 6.5 6.5 1 17 ✓<br />
RC-2S102-TP 3-18, 3-19 18 18 43 43 19 4 46 ✓<br />
RC-2S110-FO 3-38 6.5 6.5 6.5 6.5 6.5 1 17 ✓<br />
RC-2S200-TP 3-18, 3-19 22 22 44 44 68 4 60 ✓<br />
RC-2S85-FO 3-38 6.5 6.5 6.5 6.5 6.5 1 18 ✓<br />
RC-2S85-TP 3-13, 14, 15, 16, 17 18 18 33 33 51 6 60 ✓<br />
RC-2SP830-TP 3-27 18 18 24 24 36 10 39<br />
RC-4S60-TP 3-13, 3-14, 3-16 24 24 46 46 46 46 46 6 66 ✓<br />
RC-4S85-TP 3-14, 3-15, 3-16, 3-17 24 24 74 32 70 52 78 4 55 ✓<br />
RCF-2S13-H1-LD-QS 1-27, 1-29, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
RCF-2S13-M1-BS-QS 1-27, 1-29, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 6.4<br />
RCF-2S13-M1-LS-QS 1-27, 1-29, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
RCF-2S18-H1-LD-QS 1-27, 1-29, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
RCF-2S18-M1-BS-QS 1-27, 1-29, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 6.4<br />
RCF-2S18-M1-LS-QS 1-27, 1-29, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
RCF-2S26-H1-LD-QS 1-28, 1-31, 1-32, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
RCF-2S26-M1-BS-QS 1-28, 1-31, 1-32, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 6.4<br />
RCF-2S26-M1-LS-QS 1-28, 1-31, 1-32, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
RCN-1S32-SC 1-44, 1-48, 1-54, 1-58 25 36 26 25 20 28 ✓<br />
RCN-1TTP40-SC 1-35 25 30 30 25 20 28 ✓<br />
RCN-2P59 1-64 22 22 46 70 10 28 ✓<br />
RCN-2S32-SC 1-45, 1-49, 1-55, 1-59 25 25 26 26 36 20 28 ✓<br />
RCN-2TTP40-SC 1-35 25 25 30 30 20 28 ✓<br />
RCN-3S32-SC 1-46, 1-50, 1-56, 1-60 25 25 46 36 36 36 20 28 ✓<br />
RCN-3TTP40-SC 1-35 25 25 30 30 20 28 ✓<br />
RCN-4S32-SC 1-47, 1-51, 1-57, 1-61 25 25 36 36 46 36 46 20 28 ✓<br />
REB-2P32-SC 1-44, 45, 48, 49, 58, 59, 6-4 25 25 31 37 20 15<br />
REB-2S18-M1-BS-DIM 2-5, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 6.4<br />
REB-2S18-M1-LS-DIM 2-5, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
REB-2S26-M1-BS-DIM 2-5, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 6.4<br />
REB-2S26-M1-LS-DIM 2-5, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 8<br />
REB-4P32-SC 1-46, 47, 50, 51, 60, 61, 6-4 25 25 31 31 39 20 20<br />
REL-1P32-HL-SC 1-44, 48, 54, 58, 62 25 31 37 25 20 32 ✓<br />
REL-1P32-LW-SC 1-44, 1-48, 1-54, 1-58 25 31 37 25 20 32 ✓<br />
REL-1P32-SC 1-44, 1-48, 1-54, 1-58 25 31 37 25 20 24 ✓<br />
REL-1S40-SC 1-66, 1-67 22 36 26 22 20 32 ✓<br />
REL-1TTS39 1-34 12 24 24 12 10 25 ✓<br />
REL-1TTS40 1-35 12 24 24 12 10 25 ✓<br />
REL-1TTS50 1-36, 1-37 12 24 24 12 10 25 ✓<br />
REL-2P17-RH-TP 1-44, 1-45 22 22 24 24 10 25 ✓<br />
REL-2P30-G 6-5 22 22 24 24 10 25<br />
REL-2P32-HL-SC 1-45, 48, 49, 54, 55, 58, 59, 62 25 25 31 37 20 32 ✓<br />
REL-2P32-LW-SC 1-45, 49, 54, 55, 58, 59, 62 25 25 31 37 20 32 ✓<br />
REL-2P32-SC 1-45, 48, 49, 54, 55, 58, 59, 6-6 25 25 31 37 20 24 ✓<br />
REL-2P59-SC 1-64 22 22 46 70 20 20 ✓<br />
REL-2P59-S-RH-TP 1-64 22 22 46 70 10 28 ✓<br />
REL-2P60-S 1-68 22 22 46 70 6 27 ✓<br />
REL-2P64-IS 6-5 48 48 48 48 6 27<br />
REL-2S110 1-69 22 22 46 46 70 6 27 ✓<br />
REL-2S40-SC 1-66, 1-67 22 22 26 26 36 20 32 ✓<br />
REL-2S86 1-65 22 22 46 46 70 6 27 ✓<br />
REL-2TTS39 1-34 12 12 24 24 24 10 25 ✓<br />
REL-2TTS40 1-35 12 12 24 24 24 10 25 ✓<br />
REL-2TTS50 1-36, 1-37 12 12 24 24 24 10 25 ✓<br />
REL-3P32-HL-SC 1-46, 49, 50, 55, 56, 59, 60, 62 25 25 31 37 20 20 ✓<br />
REL-3P32-LW-SC 1-46, 49, 50, 55, 56, 59, 60, 62 25 25 31 37 20 28 ✓<br />
REL-3P32-SC 1-46, 49, 50, 55, 56, 59, 60, 62, 6-6 25 25 31 37 20 20 ✓<br />
*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />
*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />
** Also includes 36" violet & grey control leads.<br />
Avail<br />
IC*<br />
Ctn.<br />
8-28<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
INDEX – FLUORESCENT BALLASTS<br />
CATALOG NUMBER TO PAGE NUMBER LEAD LENGTHS AND SHIPPING DATA<br />
Catalog<br />
Number<br />
See<br />
Page<br />
No. Black White Blue Red Yellow<br />
Lead Lengths for ballasts purchased in bulk or mid-pack cartons<br />
Tolerance: +2", -1"<br />
Blue/<br />
White<br />
Black/<br />
White<br />
Yellow/<br />
Blue<br />
Brown<br />
Red/<br />
White<br />
Orange Orange/<br />
Black<br />
Units<br />
Std.<br />
Ctn.<br />
Shipping Data<br />
Weight<br />
Std.<br />
Ctn. (lbs)<br />
REL-3S40-RH-TP 1-66, 1-67 22 22 26 36 26 36 10 28 ✓<br />
REL-4P32-LW-SC 1-46, 47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 39 20 28 ✓<br />
REL-4P32-SC 1-46, 47, 50, 51, 56, 57, 60, 61, 63, 6-6 25 25 31 31 39 20 20 ✓<br />
RELB-2S40-SC 1-67, 6-4 22 22 26 26 36 20 24 ✓<br />
REZ-132-SC 2-10 22 46 26 22 20 20 ✓<br />
REZ-154 2-8, 2-9 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12<br />
REZ-1Q18-M2-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 14<br />
REZ-1Q18-M2-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16<br />
REZ-1T42-M2-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 14<br />
REZ-1T42-M2-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16<br />
REZ-1T42-M2-LD-K 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16 ✓<br />
REZ-1TTS40-SC 2-8 12 24 24 12 20 20<br />
REZ-2Q18-M2-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 14<br />
REZ-2Q18-M2-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16<br />
REZ-2Q26-M2-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 14<br />
REZ-2Q26-M2-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16<br />
REZ-2Q26-M2-LD-K 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16 ✓<br />
REZ-2S32-SC 2-10 22 22 26 26 46 20 20 ✓<br />
REZ-2S54 2-8, 2-9 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12<br />
REZ-2T42-M3-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 18<br />
REZ-2T42-M3-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 22<br />
REZ-2TTS40-SC 2-8 12 12 24 24 24 20 20<br />
REZ-3S32-SC 2-10 22 22 26 46 26 46 20 20 ✓<br />
RIF-1 3-12 6 (2) 6 6 24 22<br />
RK-132-TP 1-58 22 35 23 22 10 35 ✓<br />
RK-2S32-TP 1-59 22 22 26 26 36 10 38 ✓<br />
RK-2S34-TP 1-67 12 12 12 12 12 10 38 ✓<br />
RL-140-TP 3-8, 3-10, 3-30 36 36 25 10 20 42 ✓<br />
RL-2SP20-TP 3-27, 3-28 15 15 15 15 18 20 50 ✓<br />
RL-3SP20-TP 3-27, 3-28 12 12 15 15 18 18 10 39 ✓<br />
RLCS-140-TP-W 3-30 11 11 11 10 10 21 ✓<br />
RLQ-120-TP 3-27, 3-28 18 18 12 10 20 42 ✓<br />
RLQS-122-TP-W 3-30 13/11 11 11 13 10 22 ✓<br />
RM-2S35-TP 3-9, 3-10, 3-11 22 22 26 26 36 10 35 ✓<br />
RM-2SP30-TP 3-8 18 18 17 17 26 10 37 ✓<br />
RMB-1P13-L2 1-26, 27, 29, 40, 41, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 50 8<br />
RMB-1P13-S1 1-26, 27, 29, 40, 41, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 75 10<br />
RMB-1P13-S2-H 1-26, 27, 29, 40, 41, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 60 11<br />
RMB-1P26-S2 1-28, 31, 34, 42, 67, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 60 11<br />
RMB-2P13-L2 1-26, 27, 29, 30, 40, 41, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 50 10<br />
RMB-2P13-S2 1-26, 27, 29, 30, 40, 41, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 60 11<br />
RMB-2P13-S3-H 1-26, 27, 29, 30, 40, 41, 6-4 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 40 9<br />
RMS-22-32-TP-W 3-30 15 15 10 10 10 10 26 ✓<br />
RMS-32-40-TP-W 3-30 10 10 10 10 10 10 26 ✓<br />
ROP-2P32-LW-SC 1-44, 45, 48, 49, 54, 55, 58, 59, 62 25 25 31 37 20 32 ✓<br />
ROP-2P32-SC 1-44, 45, 48, 49, 54, 55, 58, 59, 62 25 25 31 37 20 24 ✓<br />
ROP-3P32-LW-SC 1-45, 46, 49, 50, 55, 56, 59, 60, 62, 63 25 25 31 37 20 28 ✓<br />
ROP-3P32-SC 1-45, 46, 49, 50, 55, 56, 59, 60, 62, 63 25 25 31 37 20 20 ✓<br />
ROP-4P32-HL-90C 1-46, 47, 50, 51, 60, 61, 63 25 25 31 31 39 10 20<br />
ROP-4P32-LW-SC 1-46, 47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 39 20 28 ✓<br />
ROP-4P32-SC 1-46, 47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 39 20 20 ✓<br />
RQM-2S40-TP 6-14 22 22 26 26 36 10 35<br />
RS-110-TP 3-13, 14, 15, 16, 17 22 70 46 22 6 59 ✓<br />
RS-22-32-TP-W 3-30 15 15 10 10 10 10 26 ✓<br />
RS-2S100-TP 6-6 18 18 33 33 51 6 66<br />
RS-2S200-FO 3-39 6.5 6.5 6.5 6.5 6.5 1 20 ✓<br />
RS-2S200-TP 3-18, 3-19, 6-6 22 22 44 44 68 4 60 ✓<br />
RS-32-40-TP-W 3-30 10 10 10 10 10 10 26 ✓<br />
RSM-175-S-TP 3-22, 3-23 70 46 19 10 62 ✓<br />
RZT-154 2-13, 2-14 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12<br />
RZT-1TTS40 ** 2-13 12 24 24 12 10 20<br />
*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />
*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />
** Also includes 36" violet & grey control leads.<br />
Avail<br />
IC*<br />
Ctn.<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-29
INDEX – FLUORESCENT BALLASTS<br />
REFERENCE<br />
MATERIALS<br />
CATALOG NUMBER TO PAGE NUMBER LEAD LENGTHS AND SHIPPING DATA<br />
Catalog<br />
Number<br />
See<br />
Page<br />
No. Black White Blue Red Yellow<br />
Lead Lengths for ballasts purchased in bulk or mid-pack cartons<br />
Tolerance: +2", -1"<br />
Blue/<br />
White<br />
Black/<br />
White<br />
Yellow/<br />
Blue<br />
Brown<br />
Red/<br />
White<br />
Orange Orange/<br />
Black<br />
Units<br />
Std.<br />
Ctn.<br />
Shipping Data<br />
Weight<br />
Std.<br />
Ctn. (lbs)<br />
RZT-2S54 2-13, 2-14 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12<br />
RZT-2TTS40 ** 2-13 12 12 24 24 24 10 20<br />
SM-140-S-TP 3-21 34 22 10 6 40 ✓<br />
SM-151-S-TP 3-20 68 44 10 6 54<br />
SM-2E40-S-TP 3-21 41 41 23 23 10 58 ✓<br />
SM-2E51-S-TP 3-20 70 70 46 46 6 45 ✓<br />
SM-2E57-S-TP 3-22 55 55 36 36 6 45<br />
SM-2E75-S-TP 6-16 70 70 46 46 36 6 45<br />
TM-2S40-TP 6-14 22 22 26 26 36 10 40<br />
V-140-TP 3-7, 3-9, 3-10 12 12 12 12 10 36 ✓<br />
V-1BP27-TP 3-37 12 12 12 12 10 36<br />
V-1BP39-TP 3-37 12 12 12 12 10 36<br />
V-1BP40-TP 3-37 18 28 28 18 10 36 ✓<br />
V-1P32-TP 3-5, 3-6 18 36 23 18 10 37 ✓<br />
V-1P817-TP 3-5, 3-6, 3-37 18 17 17 18 10 36<br />
V-1P825-TP 3-5, 3-6 18 24 24 18 10 36<br />
V-1P840-TP 3-5 18 44 28 18 10 37<br />
V-1U40-TP 3-11 12 12 12 12 10 36 ✓<br />
V-2BP27-TP 3-37 12 12 24 24 24 10 37<br />
V-2BS39-TP 3-37 12 12 24 24 24 10 37<br />
V-2BS40-TP 3-37 20 20 24 24 36 10 37 ✓<br />
V-2E60-S-TP 3-23 12 12 12 12 12 6 49 ✓<br />
V-2E75-S-TP 3-22, 3-23 12 12 12 12 12 6 49 ✓<br />
V-2P32-TP 3-5, 3-6 20 20 24 24 36 10 37 ✓<br />
V-2P817-TP 3-5, 3-6, 3-37 10 10 14 14 26 10 37<br />
V-2P825-TP 3-5, 3-6 12 12 20 20 32 10 37<br />
V-2P840-TP 3-5 20 20 28 28 44 10 37<br />
V-2S110-TP 3-16, 3-17 22 22 46 46 70 6 71 ✓<br />
V-2S34-TP 3-9, 3-10, 3-11 12 12 12 12 12 10 36 ✓<br />
V-2S40-TP 3-7, 3-9, 3-10, 3-11 12 12 12 12 12 10 36 ✓<br />
V-2SP30-TP 3-8 18 18 17 17 26 10 37 ✓<br />
V-3S34-TP 3-9 20 20 24 36 24 36 10 37 ✓<br />
VC-2E75-S-TP 3-22, 3-23 12 12 12 12 6 49 ✓<br />
VC-2S102-FO 3-39 6.5 6.5 6.5 6.5 6.5 1 17 ✓<br />
VC-2S102-TP 3-18, 3-19 18 18 43 43 19 4 47 ✓<br />
VC-2S110-FO 3-38 6.5 6.5 6.5 6.5 6.5 1 17 ✓<br />
VC-2S200-TP 3-18, 3-19 22 22 44 44 68 4 60 ✓<br />
VC-2S85-TP 3-13, 14, 15, 16, 17 22 22 47 47 70 6 60 ✓<br />
VCN-1S32-SC 1-44, 1-48, 1-54, 1-58 25 36 26 25 20 28 ✓<br />
VCN-1TTP40-SC 1-35 25 30 30 25 20 28 ✓<br />
VCN-2P59 1-64 22 22 46 70 10 28 ✓<br />
VCN-2S32-SC 1-45, 1-49, 1-55, 1-59 25 25 26 26 36 20 28 ✓<br />
VCN-2TTP40-SC 1-35 25 25 30 30 20 28 ✓<br />
VCN-3S32-SC 1-46, 1-50, 1-56, 1-60 25 25 46 36 36 36 20 28 ✓<br />
VCN-3TTP40-SC 1-35 25 25 30 30 20 28 ✓<br />
VCN-4S32-SC 1-47, 1-51, 1-57, 1-61 25 25 36 36 46 36 46 20 28 ✓<br />
VEL-1P32-HL-SC 1-44, 48, 54, 58, 62 25 31 37 25 20 32 ✓<br />
VEL-1P32-LW-SC 1-44, 1-48, 1-54, 1-58 25 31 37 25 20 32 ✓<br />
VEL-1P32-SC 1-44, 1-48, 1-54, 1-58 25 31 37 25 20 24 ✓<br />
VEL-1S40-SC 1-66, 1-67 22 36 26 22 20 32 ✓<br />
VEL-1TTS39 1-34 12 24 24 12 10 25 ✓<br />
VEL-1TTS40 1-35 12 24 24 12 10 25 ✓<br />
VEL-1TTS50 1-36, 1-37 12 24 24 12 10 25 ✓<br />
VEL-2P17-RH-TP 1-44, 1-45 22 22 24 24 10 25 ✓<br />
VEL-2P32-HL-SC 1-45, 48, 49, 54, 55, 58, 59, 62 25 25 31 37 20 32 ✓<br />
VEL-2P32-LW-SC 1-45, 49, 54, 55, 58, 59, 62 25 25 31 37 20 32 ✓<br />
VEL-2P32-SC 1-45, 48, 49, 54, 55, 58, 59 25 25 31 37 20 24 ✓<br />
VEL-2P59-SC 1-64 22 22 46 70 20 20 ✓<br />
VEL-2P59-S-RH-TP 1-64 22 22 46 70 10 28 ✓<br />
VEL-2P75-S 1-68 22 22 46 70 6 27 ✓<br />
*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />
*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />
** Also includes 36" violet & grey control leads.<br />
Avail<br />
IC*<br />
Ctn.<br />
8-30<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
INDEX – FLUORESCENT BALLASTS<br />
CATALOG NUMBER TO PAGE NUMBER LEAD LENGTHS AND SHIPPING DATA<br />
Catalog<br />
Number<br />
See<br />
Page<br />
No. Black White Blue Red Yellow<br />
Lead Lengths for ballasts purchased in bulk or mid-pack cartons<br />
Tolerance: +2", -1"<br />
Blue/<br />
White<br />
Black/<br />
White<br />
Yellow/<br />
Blue<br />
Brown<br />
Red/<br />
White<br />
Orange Orange/<br />
Black<br />
Units<br />
Std.<br />
Ctn.<br />
Shipping Data<br />
Weight<br />
Std.<br />
Ctn. (lbs)<br />
VEL-2S110 1-69 22 22 46 46 70 6 27 ✓<br />
VEL-2S40-SC 1-66, 1-67 22 22 26 26 36 20 32 ✓<br />
VEL-2S86 1-65 22 22 46 46 70 6 27 ✓<br />
VEL-2TTS39 1-34 12 12 24 24 24 10 25 ✓<br />
VEL-2TTS40 1-35 12 12 24 24 24 10 25 ✓<br />
VEL-2TTS50 1-36, 1-37 12 12 24 24 24 10 25 ✓<br />
VEL-3P32-HL-SC 1-46, 49, 50, 55, 56, 59, 60, 62 25 25 31 37 20 20 ✓<br />
VEL-3P32-LW-SC 1-45, 46, 49, 50, 55, 56, 59, 60, 62 25 25 31 37 20 28 ✓<br />
VEL-3P32-SC 1-46, 49, 50, 55, 56, 59, 60, 62 25 25 31 37 20 20 ✓<br />
VEL-3S40-RH-TP 1-66, 1-67 22 22 26 36 26 36 10 28 ✓<br />
VEL-4P32-LW-SC 1-46, 47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 39 20 28 ✓<br />
VEL-4P32-SC 1-47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 39 20 20 ✓<br />
VEZ-132-SC 2-10 22 46 26 22 20 20 ✓<br />
VEZ-154 2-8, 2-9 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12<br />
VEZ-1Q18-M2-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 14<br />
VEZ-1Q18-M2-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16<br />
VEZ-1T42-M2-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 14<br />
VEZ-1T42-M2-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16<br />
VEZ-1T42-M2-LD-K 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16 ✓<br />
VEZ-1TTS40-SC 2-8 12 24 24 12 20 20<br />
VEZ-2Q18-M2-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 14<br />
VEZ-2Q18-M2-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16<br />
VEZ-2Q26-M2-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 14<br />
VEZ-2Q26-M2-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16<br />
VEZ-2Q26-M2-LD-K 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 16 ✓<br />
VEZ-2S32-SC 2-10 22 22 26 26 46 20 20 ✓<br />
VEZ-2S54 2-8, 2-9 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12<br />
VEZ-2T42-M3-BS 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 16 18<br />
VEZ-2T42-M3-LD 2-7 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 20 22<br />
VEZ-2TTS40-SC 2-8 12 12 24 24 24 20 20<br />
VEZ-3S32-SC 2-10 22 22 26 46 26 46 20 20 ✓<br />
VH-1B13-TP-BLS 3-34 7 7 7 27 38<br />
VH-1B13-TP-W 3-34 15 15 15 24 34 ✓<br />
VH-1B9-TP-BLS 3-33 7 7 7 27 30<br />
VH-1B9-TP-W 3-33 15 15 15 24 26<br />
VH-1Q18-TP-BLS 3-35 7 7 7 27 40<br />
VH-1Q18-TP-W 3-35 15 15 15 24 36<br />
VH-1Q26-TP-BLS 3-35 7 7 7 27 40<br />
VH-1Q26-TP-W 3-35 15 15 15 24 36 ✓<br />
VH-2B13-TP-BLS 3-34 7 7 7 27 40<br />
VH-2B13-TP-W 3-34 15 15 15 24 36<br />
VH-2B9-TP-BLS 3-33 7 7 7 27 32<br />
VH-2B9-TP-W 3-33 15 15 15 24 29<br />
VH-2Q18-TP-BLS 3-35 7 7 7 10 33<br />
VH-2Q18-TP-W 3-35 15 15 15 10 33<br />
VH-2Q26-TP-BLS 3-35 7 7 7 10 36<br />
VH-2Q26-TP-W 3-35 15 15 15 10 36<br />
VHM-1P20-TP 3-27, 3-28 8 10 10 8 10 32 ✓<br />
VK-132-TP 1-58 22 35 23 22 10 35 ✓<br />
VK-2S32-TP 1-59 22 22 26 26 36 10 38 ✓<br />
VK-2S34-TP 1-67 12 12 12 12 12 10 38 ✓<br />
VL-1B13-TP-BLS 3-34 7 7 27 38<br />
VL-1B13-TP-W 3-34 15 15 24 34 ✓<br />
VL-1B9-TP-BLS 3-33 7 7 27 32<br />
VL-1B9-TP-W 3-33 15 15 24 29 ✓<br />
VL-1Q18-TP-BLS 3-35 7 7 27 38<br />
VL-1Q18-TP-W 3-35 15 15 24 34<br />
VL-1Q26-TP-BLS 3-35 7 7 27 43<br />
VL-1Q26-TP-W 3-35 15 15 24 38<br />
VLO-13-TP 3-31, 3-32 15 15 72 72 ✓<br />
VLO-2S13-TP 3-31 7 7 20 26 ✓<br />
*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />
*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />
** Also includes 36" violet & grey control leads.<br />
Avail<br />
IC*<br />
Ctn.<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-31
INDEX – FLUORESCENT BALLASTS<br />
CATALOG NUMBER TO PAGE NUMBER LEAD LENGTHS AND SHIPPING DATA<br />
Catalog<br />
Number<br />
See<br />
Page<br />
No. Black White Blue Red Yellow<br />
Lead Lengths for ballasts purchased in bulk or mid-pack cartons<br />
Tolerance: +2", -1"<br />
Blue/<br />
White<br />
Black/<br />
White<br />
Yellow/<br />
Blue<br />
Brown<br />
Red/<br />
White<br />
Orange Orange/<br />
Black<br />
Units<br />
Std.<br />
Ctn.<br />
Shipping Data<br />
Weight<br />
Std.<br />
Ctn. (lbs)<br />
VLQ-106F-TP 3-27 10 10 10 10 20 40 ✓<br />
VM-1P30-TP 3-8 18 26 17 18 10 34 ✓<br />
VM-2SP20-TP 3-27, 3-28 10 10 13 13 16 10 34 ✓<br />
VM-2SP30-TP 3-8 18 18 17 17 26 10 36 ✓<br />
VOP-2P32-LW-SC 1-44, 45, 48, 49, 54, 55, 58, 59, 62 25 25 31 37 20 32 ✓<br />
VOP-2P32-SC 1-44, 45, 48, 49, 54, 55, 58, 59, 62 25 25 31 37 20 24 ✓<br />
VOP-3P32-LW-SC 1-45, 46, 49, 50, 55, 56, 59, 60, 62, 63 25 25 31 37 20 28 ✓<br />
VOP-3P32-SC 1-45, 46, 49, 50, 55, 56, 59, 60, 62, 63 25 25 31 37 20 20 ✓<br />
VOP-4P32-HL-90C 1-47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 39 10 20<br />
VOP-4P32-LW-SC 1-46, 47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 39 20 28 ✓<br />
VOP-4P32-SC 1-46, 47, 50, 51, 56, 57, 60, 61, 63 25 25 31 31 39 20 20 ✓<br />
VQM-2S40-TP 6-14 22 22 26 26 36 10 35<br />
VS-110-TP 3-13, 14, 15, 16, 17 22 40 46 22 6 59 ✓<br />
VS-2S200-FO 3-39 6.5 6.5 6.5 6.5 6.5 1 20 ✓<br />
VS-2S200-TP 3-18, 3-19 22 22 44 44 68 4 60 ✓<br />
VSB-0412-12-BL-TP 3-40 18 18 33 33 51 1 12 ✓<br />
VSB-0620-24-BL-TP 3-40 24 24 75 46 75 46 46 1 12 ✓<br />
VSB-1224-24-BL-TP 3-40 24 24 74 32 70 52 78 1 14 ✓<br />
VSB-1240-46-BL-TP 3-40 24 24 50 80 70 50 50 50 50 1 21 ✓<br />
VSB-2040-24-BL-TP 3-40 24 24 80 80 72 54 72 1 21 ✓<br />
VSB-2448-46-BL-TP 3-40 24 24 50 50 70 50 50 50 50 1 21 ✓<br />
VSM-175-S-TP 3-22, 3-23 70 48 10 10 62 ✓<br />
VSM-2E40-S-TP 3-21 25 35 23 23 35 10 58 ✓<br />
VSM-2E75-S-TP 6-16 19 70 46 46 70 6 45<br />
VZT-154 2-13, 2-14 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12<br />
VZT-180 2-13, 2-14 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12<br />
VZT-1TTS40 ** 2-13 12 24 24 12 10 20<br />
VZT-2S54 2-13, 2-14 N N N N No N Leads N- Poke in NConnectors<br />
N N N N N 12 12<br />
VZT-2TTS40 ** 2-13 12 12 24 24 24 10 20<br />
VZT-4S32-HL ** 2-16 12 12 12 15 59 15 45 6 12<br />
X-140-TP 3-7, 3-9, 3-10 22 35 23 22 10 36<br />
XHM-1P20-TP 6-17 8 10 10 8 10 32<br />
XM-2SP20-TP 6-17 10 10 13 13 16 10 34<br />
XQM-2S40-TP 3-7, 3-9, 3-10, 3-11 22 22 26 26 36 10 34<br />
XSM-2E75-S-TP 3-22, 3-23 19 70 46 46 70 6 49<br />
XTH-1B13-TP-W 6-17 15 15 15 24 36<br />
YHQM-1P40-TP 3-7, 3-8, 3-10 18 35 23 18 10 36<br />
YK-2S32-TP 1-59 22 22 26 26 36 10 38<br />
YQM-2S40-TP 3-7, 3-9, 3-10, 3-11 18 18 24 24 36 10 35 ✓<br />
YS-2S110-TP 3-16, 3-17 22 22 46 46 70 6 61<br />
YS-2S85-TP 3-13, 14, 15, 16, 17 (2) 22 47 47 70 6 60<br />
YSM-2E75-S-TP 3-22, 3-23 19 70 46 46 70 6 49<br />
Avail<br />
IC*<br />
Ctn.<br />
*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />
*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />
** Also includes 36" violet & grey control leads.<br />
REFERENCE<br />
MATERIALS<br />
*Electromagnetic ballasts packed in individual cartons (IC) have shorter leads, typically 12 inches.<br />
*<strong>Electronic</strong> ballasts in individual cartons (IC) have same lead lengths as listed in table.<br />
8-32<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
INDEX – HID BALLASTS<br />
CATALOG NUMBER TO PAGE NUMBER<br />
Catalog<br />
Number<br />
Page<br />
Number<br />
7180J9 5-37<br />
71A0280 5-46<br />
71A0490 5-46<br />
71A0490-001D 5-7, 5-46<br />
71A04F0 5-46<br />
71A0590 5-47<br />
71A0590-001D 5-7, 5-47<br />
71A05F0 5-47<br />
71A0790 5-47<br />
71A0790-001D 5-7, 5-47<br />
71A07F0 5-47<br />
71A1580 5-14<br />
71A1800 5-14<br />
71A1800-001 5-7, 5-14<br />
71A2080 5-14<br />
71A2303 5-14<br />
71A2501 5-14<br />
71A2541 5-14<br />
71A2571-001D 5-7, 5-14<br />
71A2591 5-14<br />
71A25A1 5-14<br />
71A25A1-001D 5-9, 5-14<br />
71A2800 5-14<br />
71A2800-001 5-7, 5-14<br />
71A29D1 5-15<br />
71A29D1-001D 5-9, 5-15<br />
71A3002 5-15<br />
71A3042 5-15<br />
71A3042-001D 5-7, 5-15<br />
71A3072-001D 5-7, 5-15<br />
71A3092 5-15<br />
71A30D2 5-15<br />
71A30D2-001D 5-9, 5-15<br />
71A3301 5-15<br />
71A3301-001 5-7, 5-15<br />
71A3304-791 5-8<br />
71A3325 5-15<br />
71A3325-791 5-8<br />
71A3502 5-16<br />
71A3542 5-16<br />
71A3542-001D 5-7, 5-16<br />
71A3542-T 5-16<br />
71A3572-001D 5-7, 5-16<br />
71A3592 5-16<br />
71A35D2 5-16<br />
71A35D2-001D 5-9, 5-16<br />
71A35J2 5-16<br />
71A3801-791 5-8<br />
71A3802 5-16<br />
71A4041 5-17<br />
71A4041-001D 5-7, 5-17<br />
71A4041-T 5-17<br />
71A4071-001D 5-7, 5-17<br />
71A4091 5-17<br />
71A40D1 5-17<br />
71A40D1-001D 5-9, 5-17<br />
71A4300-001 5-7, 5-17<br />
71A4330-001 5-7, 5-17<br />
71A4340-001 5-7, 5-17<br />
71A5005-P 5-18<br />
71A5037-BP 5-18<br />
71A5037-J 5-18<br />
71A5037-P 5-18<br />
71A5040-001 5-7, 5-17<br />
71A5070-001 5-7, 5-17<br />
71A5081 5-18<br />
71A5105-P 5-18<br />
71A5137-BP 5-18<br />
71A5137-J 5-18<br />
71A5137-P 5-18<br />
71A5181 5-18<br />
Catalog<br />
Number<br />
Page<br />
Number<br />
71A5181-001D 5-5, 5-18<br />
71A5205-P 5-19<br />
71A5237-BP 5-19<br />
71A5237-J 5-19<br />
71A5237-P 5-19<br />
71A5280 5-19<br />
71A5281 5-19<br />
71A5282 5-19<br />
71A5292 5-19<br />
71A5292-001D 5-5, 5-19<br />
71A52A2 5-19<br />
71A52A2-001D 5-9, 5-19<br />
71A52C0 5-19<br />
71A52C1 5-19<br />
71A52H2 5-19<br />
71A5337-BP 5-20<br />
71A5337-J 5-20<br />
71A5337-P 5-20<br />
71A5340-T 5-20<br />
71A5380 5-20<br />
71A5383 5-20<br />
71A5390 5-20<br />
71A5390-001D 5-5, 5-20<br />
71A53A0 5-20<br />
71A53A0-001D 5-9, 5-20<br />
71A53H0 5-20<br />
71A5437-BP 5-21<br />
71A5437-J 5-21<br />
71A5437-P 5-21<br />
71A5442-T 5-21<br />
71A5480 5-21<br />
71A5482 5-21<br />
71A5486 5-21<br />
71A5490 5-21<br />
71A5492 5-21<br />
71A5492-001D 5-5, 5-21<br />
71A54A2 5-21<br />
71A54A3 5-21<br />
71A54C0 5-21<br />
71A5500 5-22<br />
71A5504 5-22<br />
71A5530 5-22<br />
71A5534-T 5-22<br />
71A5540 5-22<br />
71A5540-001D 5-5, 5-22<br />
71A5540-T 5-22<br />
71A5543-T 5-22<br />
71A5544-T 5-22<br />
71A5570-001D 5-5, 5-22<br />
71A5580 5-22<br />
71A5590 5-22<br />
71A5593 5-22<br />
71A5593-001D 5-5, 5-22<br />
71A55A0 5-22<br />
71A55A0-001D 5-9, 5-22<br />
71A55A3 5-22<br />
71A55B4-T 5-22<br />
71A55H0 5-22<br />
71A5634-T 5-23<br />
71A5637-001D 5-5, 5-23<br />
71A5637-BP 5-23<br />
71A5642-T 5-23<br />
71A5692 5-23<br />
71A5692-001D 5-5, 5-23<br />
71A5693 5-23<br />
71A56A2 5-23<br />
71A56A3 5-23<br />
71A5700 5-24<br />
71A5701 5-24<br />
71A5704 5-25<br />
71A5724-T 5-25<br />
Catalog<br />
Number<br />
Page<br />
Number<br />
71A5730 5-24<br />
71A5731 5-24<br />
71A5734-T 5-25<br />
71A5737-001D 5-5, 5-25<br />
71A5737-BP 5-25<br />
71A5740 5-24<br />
71A5740-001D 5-5, 5-24<br />
71A5740-T 5-24<br />
71A5741 5-24<br />
71A5741-001D 5-5, 5-24<br />
71A5742-T 5-25<br />
71A5744-T 5-25<br />
71A5750 5-24<br />
71A5750-001D 5-5, 5-24<br />
71A5770-001D 5-5, 5-24<br />
71A5771-001D 5-5, 5-24<br />
71A5780 5-24<br />
71A5790 5-24<br />
71A5791 5-24<br />
71A5792 5-25<br />
71A5792-001D 5-5, 5-25<br />
71A57A0 5-24<br />
71A57A0-001D 5-9, 5-24<br />
71A57A2 5-25<br />
71A57B4-T 5-25<br />
71A57E6 5-24<br />
71A57H0 5-24<br />
71A5837-001D 5-5, 5-26<br />
71A5837-BP 5-26<br />
71A5842-001DT 5-5, 5-26<br />
71A5842-T 5-26<br />
71A5892 5-26<br />
71A5892-001D 5-5, 5-26<br />
71A5892-LL 5-26<br />
71A58A2 5-26<br />
71A58H2 5-26<br />
71A5934-T 5-26<br />
71A5937-001D 5-5, 5-26<br />
71A5937-BP 5-26<br />
71A5943-T 5-26<br />
71A5993 5-26<br />
71A5993-001D 5-5, 5-26<br />
71A59A3 5-26<br />
71A6001 5-27<br />
71A6004 5-28<br />
71A6031 5-27<br />
71A6034-T 5-28<br />
71A6037-001D 5-5, 5-27<br />
71A6037-B 5-27<br />
71A6041 5-27<br />
71A6041-001D 5-5, 5-27<br />
71A6041-T 5-27<br />
71A6042-T 5-28<br />
71A6044-T 5-28<br />
71A6051 5-27<br />
71A6051-001D 5-5, 5-27<br />
71A6071-001D 5-5, 5-27<br />
71A6081 5-27<br />
71A6091 5-27<br />
71A6092 5-28<br />
71A6092-001D 5-5, 5-28<br />
71A6092-LL 5-28<br />
71A60A1 5-27<br />
71A60A1-001D 5-9, 5-27<br />
71A60A2 5-28<br />
71A60B4-T 5-28<br />
71A60E4-T 5-28<br />
71A60E6 5-27<br />
71A60F6 5-27<br />
71A60H1 5-27<br />
71A6137-001D 5-5, 5-28<br />
Catalog<br />
Number<br />
Page<br />
Number<br />
71A6137-BP 5-28<br />
71A6334-T 5-28<br />
71A6337-001D 5-5<br />
71A6337-BP 5-28<br />
71A6342-001D 5-5<br />
71A6343-T 5-28<br />
71A6382-001D 5-5<br />
71A6393 5-28<br />
71A6393-001D 5-5<br />
71A63A3 5-28<br />
71A6490 5-29<br />
71A6498 5-29<br />
71A64E2 5-29<br />
71A64F0-T 5-29<br />
71A64F2 5-29<br />
71A64F2-001D 5-5, 5-29<br />
71A64F2-T 5-29<br />
71A64F8-T 5-29<br />
71A6502 5-30<br />
71A6532 5-30<br />
71A6542 5-30<br />
71A6542-001 5-5, 5-30<br />
71A6542-T 5-30<br />
71A6552 5-30<br />
71A6552-001 5-5, 5-30<br />
71A6572-001 5-5, 5-30<br />
71A6590 5-30<br />
71A6591 5-30<br />
71A6592 5-30<br />
71A6593 5-30<br />
71A65A2 5-30<br />
71A65A2-001 5-9, 5-30<br />
71A65E6-T 5-30<br />
71A65F0-T 5-30<br />
71A65F1-T 5-30<br />
71A65F3-T 5-30<br />
71A65J2 5-30<br />
71A6702 5-31<br />
71A6732 5-31<br />
71A6742 5-31<br />
71A6742-001 5-5, 5-31<br />
71A6772-001 5-5, 5-31<br />
71A6792 5-31<br />
71A67A2 5-31<br />
71A67A2-001 5-9, 5-31<br />
71A67J2 5-31<br />
71A6890 5-31<br />
71A68F0 5-31<br />
71A69EO 5-31<br />
71A69H0 5-31<br />
71A7707 5-32<br />
71A7707-001DB 5-6, 5-32<br />
71A7707-B 5-32<br />
71A7801 5-33<br />
71A7801-001D 5-6, 5-33<br />
71A7805 5-33<br />
71A7807 5-33<br />
71A7807-001DB 5-6, 5-33<br />
71A7807-B 5-33<br />
71A7901 5-34<br />
71A7907 5-34<br />
71A7907-001DB 5-6, 5-34<br />
71A7907-791 5-8<br />
71A7907-B 5-34<br />
71A7941 5-34<br />
71A7950 5-35<br />
71A7971-001D 5-6, 5-34<br />
71A7988 5-35<br />
71A7991 5-34<br />
71A7991-001DC 5-6<br />
71A79A1 5-34<br />
Catalog<br />
Number<br />
Page<br />
Number<br />
71A79A1-001D 5-9, 5-34<br />
71A79E6 5-35<br />
71A79H8 5-35<br />
71A79J1 5-34<br />
71A8001 5-36<br />
71A8005 5-36<br />
71A8005 5-36<br />
71A8007 5-36<br />
71A8007-001DB 5-6,, 5-36<br />
71A8007-791 5-8<br />
71A8007-B 5-36<br />
71A8041 5-36<br />
71A8041-001D 5-6, 5-36<br />
71A8048-T 5-37<br />
71A8050 5-37<br />
71A8056 5-37<br />
71A8060 5-37<br />
71A8071-001D 5-6, 5-36<br />
71A8080 5-37<br />
71A8088 5-37<br />
71A8091 5-36<br />
71A8091-001DC 5-6<br />
71A80A1 5-36<br />
71A80A1-001D 5-9, 5-36<br />
71A80EG 5-37<br />
71A80H8 5-37<br />
71A80J1 5-36<br />
71A80J8 5-37<br />
71A8102 5-38<br />
71A8107 5-38<br />
71A8107-001DB 5-6, 5-38<br />
71A8107-791 5-8<br />
71A8107-B 5-38<br />
71A8132 5-38<br />
71A8142 5-38<br />
71A8142-001D 5-6, 5-38<br />
71A8142-T 5-38<br />
71A8146-001D 5-6, 5-39<br />
71A8148 5-39<br />
71A8150 5-39<br />
71A8160 5-39<br />
71A8172-001D 5-6, 5-38<br />
71A8176-001D 5-6, 5-39<br />
71A8180 5-39<br />
71A8188 5-39<br />
71A8192 5-38<br />
71A8192-001DC 5-6<br />
71A8196 5-39<br />
71A81A2 5-38<br />
71A81A2-001D 5-9, 5-38<br />
71A81E6 5-39<br />
71A81H8 5-39<br />
71A81J2 5-38<br />
71A81J9 5-39<br />
71A8201 5-41<br />
71A8231 5-41<br />
71A8241 5-41<br />
71A8241-001D 5-7, 5-41<br />
71A8241-T 5-41<br />
71A8250 5-41<br />
71A8251 5-41<br />
71A8251-001D 5-7, 5-41<br />
71A8260 5-41<br />
71A8271-001D 5-7, 5-41<br />
71A8280 5-41<br />
71A8281 5-41<br />
71A8291 5-41<br />
71A8291-001DC 5-7<br />
71A8296 5-41<br />
71A82A1 5-41<br />
71A82A1-001D 5-9, 5-41<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-33
INDEX – HID BALLASTS<br />
REFERENCE<br />
MATERIALS<br />
CATALOG NUMBER TO PAGE NUMBER<br />
Catalog<br />
Number<br />
Page<br />
Number<br />
71A82E6 5-41<br />
71A82H1 5-41<br />
71A82J9 5-41<br />
71A8341 5-42<br />
71A8350 5-42<br />
71A8351 5-42<br />
71A8360 5-42<br />
71A8371-001D 5-7, 5-42<br />
71A8391 5-42<br />
71A8403 5-43<br />
71A8433 5-43<br />
71A8440-T 5-43<br />
71A8443 5-43<br />
71A8443-001D 5-7, 5-43<br />
71A8443-001DC 5-7<br />
71A8443-T 5-43<br />
71A8450 5-43<br />
71A8453 5-43<br />
71A8453-001D 5-7, 5-43<br />
71A8456 5-43<br />
71A8460 5-43<br />
71A8473-001D 5-7, 5-43<br />
71A8480 5-43<br />
71A8493 5-43<br />
71A8493-001DC 5-7<br />
71A84A3 5-43<br />
71A84A3-001D 5-9, 5-43<br />
71A84E6 5-43<br />
71A84H3 5-43<br />
71A85E5 5-44<br />
71A85E6 5-44<br />
71A85E8 5-44<br />
71A85F5 5-44<br />
71A85F6 5-44<br />
71A85F8 5-44<br />
71A86E5 5-44<br />
71A86E5 5-29<br />
71A86F5 5-44<br />
71A86F5 5-29<br />
71A8703 5-45<br />
71A8733 5-45<br />
71A8743 5-45<br />
71A8743-001 5-7, 5-45<br />
71A8743-001C 5-7<br />
71A8753 5-45<br />
71A8753-001 5-7, 5-45<br />
71A8773-001 5-7, 5-45<br />
71A8793 5-45<br />
71A8793-001C 5-7<br />
71A87A3 5-45<br />
71A87A3-001 5-9, 5-45<br />
71A87J3 5-45<br />
71A8940 5-40<br />
71A8940-001D 5-7, 5-40<br />
71A8941 5-40<br />
71A8950 5-40<br />
71A8954 5-40<br />
71A8964 5-40<br />
71A8970-001D 5-7, 5-40<br />
71A8990 5-40<br />
71A8991 5-40<br />
71A9325 5-55<br />
71A9740 5-55<br />
71A9741 5-55<br />
71A9742 5-55<br />
71A9743 5-55<br />
71A9744 5-55<br />
71A9749 5-55<br />
71A9833 5-55<br />
71A9839 5-55<br />
71A9846 5-55<br />
Catalog<br />
Number<br />
Page<br />
Number<br />
71A9847 5-33, 5-55<br />
71A9862 5-55<br />
71A9876 5-36, 5-55<br />
71A9877 5-55<br />
71A9885 5-55<br />
71A9900 5-55<br />
72C2584-NP 5-56<br />
72C2584-NP-001 5-56<br />
72C25C4-NP 5-56<br />
72C29C4-NP 5-56<br />
72C3084-NP 5-56<br />
72C3084-NP-001 5-56<br />
72C30C4-NP 5-56<br />
72C3584-NP 5-56<br />
72C3584-NP-001 5-56<br />
72C4083-NP 5-56<br />
72C4083-NP-001 5-56<br />
72C5005-NP 5-57<br />
72C5005-NP-BLS 5-57<br />
72C5081-NP 5-57<br />
72C5181-NP 5-57<br />
72C5181-NP-001 5-57<br />
72C51C1-NP 5-57<br />
72C5280-NP 5-57<br />
72C5280-NP-001 5-57<br />
72C5281-NP 5-57<br />
72C5281-NP-900 5-57<br />
72C5282-NP 5-57<br />
72C5282-NP-001 5-57<br />
72C5282-NP-900 5-57<br />
72C52C0-NP 5-57<br />
72C52C1-NP-900 5-57<br />
72C52C2-NP 5-57<br />
72C5381-NP 5-57<br />
72C5381-NP-001 5-57<br />
72C5381-NP-900 5-57<br />
72C53C1-NP 5-57<br />
72C5481-NP 5-57<br />
72C5482-NP 5-57<br />
72C5482-NP-900 5-57<br />
72C54C1-NP 5-57<br />
72C54C2-NP-900 5-57<br />
72C5581-NP 5-58<br />
72C5581-NP-001 5-58<br />
72C5582-NP 5-58<br />
72C5582-NP-001 5-58<br />
72C55C1-NP 5-58<br />
72C5782-NP 5-58<br />
72C5782-NP-001 5-58<br />
72C5783-NP 5-58<br />
72C5783-NP-001 5-58<br />
72C57C2-NP 5-58<br />
72C5882-NP 5-58<br />
72C5882-NP-001 5-58<br />
72C5983-NP 5-58<br />
72C5983-NP-001 5-58<br />
72C6082-NP 5-58<br />
72C6082-NP-WC 5-58<br />
72C6182-NP 5-58<br />
72C6182-NP-001 5-58<br />
72C7705-NP 5-59<br />
72C7805-NP 5-59<br />
72C7884-NP 5-59<br />
72C7884-NP-001 5-59<br />
72C7984-NP 5-59<br />
72C7984-NP-001 5-59<br />
72C79C4-NP 5-59<br />
72C8005-NP 5-59<br />
72C8084-NP 5-59<br />
72C8084-NP-001 5-59<br />
72C80C4-NP 5-59<br />
Catalog<br />
Number<br />
Page<br />
Number<br />
72C8185-NP 5-59<br />
72C81C5-NP 5-59<br />
72C8680-NP 5-59<br />
73B2591 5-60<br />
73B3092 5-60<br />
73B3592 5-60<br />
73B4091 5-60<br />
73B5282 5-61<br />
73B5380 5-61<br />
73B5383 5-61<br />
73B5482 5-61<br />
73B5590 5-61<br />
73B55A0 5-61<br />
73B5790 5-61<br />
73B5792 5-61<br />
73B57A0 5-61<br />
73B5892 5-61<br />
73B5993 5-61<br />
73B6091 5-62<br />
73B6092 5-62<br />
73B60A1 5-62<br />
73B6590 5-62<br />
73B6592 5-62<br />
73B65A2 5-62<br />
73B7805 5-63<br />
73B8005 5-63<br />
73B8281 5-63<br />
73B8483 5-63<br />
74P1501-011P 5-64<br />
74P1801-011 5-64<br />
74P2001-011P 5-64<br />
74P2301-011 5-64<br />
74P2503-011P 5-64<br />
74P2513-011P 5-64<br />
74P2523-011P 5-64<br />
74P2533-011P 5-64<br />
74P2802-011 5-64<br />
74P2832-011 5-64<br />
74P3003-011P 5-65<br />
74P3013-011P 5-65<br />
74P3023-011P 5-65<br />
74P3033-011P 5-65<br />
74P3303-011 5-65<br />
74P3313-011 5-65<br />
74P3323-011 5-65<br />
74P3333-011 5-65<br />
74P3503-011P 5-65<br />
74P3513-011P 5-65<br />
74P3523-011P 5-65<br />
74P3533-011P 5-65<br />
74P5103-011 5-66<br />
74P5104-011P 5-66<br />
74P7702-011 5-67<br />
74P7703-011P 5-67<br />
74P7802-011 5-67<br />
74P7803-011P 5-67<br />
74P7902-011 5-67<br />
74P7903-011P 5-67<br />
74P7913-011P 5-67<br />
74P7923-011P 5-67<br />
74P7933-011P 5-67<br />
74P8002-011 5-67<br />
74P8003-011P 5-67<br />
74P8013-011P 5-67<br />
74P8023-011P 5-67<br />
74P8033-011P 5-67<br />
74P8103-011 5-67<br />
74P8104-011P 5-67<br />
77K5570-001D 5-10<br />
77K5770-001D 5-10<br />
77K5837-001D 5-10<br />
Catalog<br />
Number<br />
Page<br />
Number<br />
77K5892-001D 5-10<br />
77K5937-001D 5-10<br />
77K5993-001D 5-10<br />
77K6071-001D 5-10<br />
77K8071-001D 5-10<br />
77K8172-001D 5-10<br />
77K8271-001D 5-10<br />
77K8473-001D 5-10<br />
77L5570-001D 5-11<br />
77L5750-001D 5-11<br />
77L6051-001D 5-11<br />
77L6552-001 5-11<br />
77L8071-001D-MED 5-11<br />
77L8172-001D-MOG 5-11<br />
77L8251-001D 5-11<br />
77L8453-001D 5-11<br />
77L8753-001 5-11<br />
78E8291-001 5-68<br />
78E8443-001 5-68<br />
78E8493-001 5-68<br />
78E8743-001 5-68<br />
78E8793-001 5-68<br />
78E8940-001 5-68<br />
79W2591-001 5-69<br />
79W3542-001 5-69<br />
79W3592-001 5-69<br />
79W5590-001 5-70<br />
79W5790-001 5-70<br />
79W6041-001 5-70<br />
79W6091-001 5-70<br />
79W6341-001 5-70<br />
79W6351-001 5-70<br />
79W6542-001 5-70<br />
79W6592-001 5-70<br />
79W6742-001 5-70<br />
79W6792-001 5-70<br />
79W8192-001 5-71<br />
79W8241-001 5-71<br />
79W8291-001 5-71<br />
79W8443-001 5-71<br />
79W8493-001 5-71<br />
79W8743-001 5-71<br />
79W8793-001 5-71<br />
79W9597-001 5-71<br />
EHID<br />
Catalog<br />
Number<br />
IGNITORS<br />
Page<br />
Number<br />
IMG-100-A-BLS 4-5<br />
IMG-100-D-BLS 4-6<br />
IMG-150-H-BLS 4-6<br />
IMG-239-A-BLS 4-5<br />
IMG-39-G-BLS 4-5<br />
IMG-70-G-BLS 4-5<br />
IMH-100-A-BLS 4-5<br />
IMH-100-A-LF 4-5<br />
IMH-100-D-LF 4-6<br />
IMH-150-H-LF 4-6<br />
IMH-175-C-BLS 4-6<br />
IMH-175-C-LF 4-6<br />
IMH-200-C-LF 4-6<br />
IMH-239-A-LF 4-5<br />
IMH-39-G-LF 4-5<br />
IMH-39-J-LF 4-5<br />
IMH-50-A-BLS 4-5<br />
IMH-50-A-LF 4-5<br />
IMH-70-D-BLS 4-5<br />
IMH-70-G-LF 4-5<br />
IMH-70-J-LF 4-5<br />
IWSN-150-H-BLS 4-6<br />
IWSN-150-H-LF 4-6<br />
IZTEM4003PS-F 4-10<br />
IZTEM400EPS-F 4-10<br />
IZTEMH4003PS 4-10<br />
IZTEMH4003PS-F 4-10<br />
IZTMH-150-C-LF 4-10<br />
IZTSN-150-C-LF 4-10<br />
RMH-20-E-LF 4-5<br />
RMH-39-K-LF 4-5<br />
RMH-39-K-LFS 4-5<br />
Catalog<br />
Number<br />
Page<br />
Number<br />
6C035-IC 5-53<br />
6C050-IC 5-53<br />
6C100-IC 5-53<br />
LI501-H4-IC 5-53, 5-54<br />
LI501-J4-IC 5-51, 5-53, 5-54, 5-55<br />
LI522-H5-IC 5-51<br />
LI523-H5-IC 5-51<br />
LI533-H4-IC 5-51<br />
LI534-H5-IC 5-51<br />
LI551-H4-IC 5-53<br />
LI551-J4-IC 5-53<br />
LI561-H5 5-51<br />
LI561-H5-IC 5-51, 5-54<br />
LI571-H5-IC 5-51, 5-54<br />
LI571-J5-IC 5-55<br />
LI572-H5-IC 5-51<br />
LI573-H5 5-51<br />
LI573-H5-IC 5-51<br />
LI5xxSQ 5-52<br />
LI5xxSQR 5-52<br />
LISOD1 5-52<br />
LISOD1-IC 5-52<br />
8-34<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
INDEX – FLUORESCENT BALLASTS<br />
REFERENCE<br />
MATERIALS<br />
DISCONTINUED CATALOG NUMBER TO REPLACEMENT NUMBER<br />
Electromagnetic Fluorescent Electromagnetic Fluorescent Electromagnetic Fluorescent<br />
Discontinued<br />
Catalog<br />
Number<br />
Current<br />
Catalog<br />
Number<br />
Page<br />
No.<br />
038-A40 - -<br />
065-A40 ASB-0620-24-BL-TP 3-40<br />
217-A40 - -<br />
268-A40 ASB-0412-12-BL-TP 3-40<br />
276-A40 - -<br />
296-A40 - -<br />
492-A40 ASB-0620-24-BL-TP 3-40<br />
494-A40 - -<br />
580-A40 - -<br />
752-A40 ASB-0620-24-BL-TP 3-40<br />
760-A40 - -<br />
762-A40 - -<br />
763-A40 - -<br />
826-A40 ASB-0620-24-BL-TP 3-40<br />
834-A40 - -<br />
843-A40 ASB-2040-24-BL-TP 3-40<br />
844-A40 ASB-1224-24-BL-TP 3-40<br />
849-A40 - -<br />
868-A40 - -<br />
902-A40 - -<br />
903-A40 - -<br />
915-A40 - -<br />
944-A40 ASB-1224-24-BL-TP 3-40<br />
957-A40 - -<br />
966-A40 ASB-0412-12-BL-TP 3-40<br />
967-A40 - -<br />
976-A40 ASB-0620-24-BL-TP 3-40<br />
977-A40 - -<br />
A-175-S RSM-175-S-TP 3-22, 3-23<br />
A-2E75-S R-2E75-S-TP 3-22, 3-23<br />
AD-240 - -<br />
ADM-251-S SM-2E51-S-TP 3-20<br />
ADM-2E40-S SM-2E40-S-TP 3-20<br />
ADM-2E75-S R-2E75-S-TP 3-22, 3-23<br />
ASB-0412-12 ASB-0412-12-BL-TP 3-40<br />
ASB-0412-12-BL ASB-0412-12-BL-TP 3-40<br />
ASB-06-20-24 ASB-06-20-24-BL-TP 3-40<br />
ASB-06-20-24-BL ASB-06-20-24-BL-TP 3-40<br />
ASB-1224-24 ASB-1224-24-BL-TP 3-40<br />
ASB-1224-24-BL ASB-1224-24-BL-TP 3-40<br />
ASB-1240-46 ASB-1240-46-BL-TP 3-40<br />
ASB-1240-46-BL ASB-1240-46-BL-TP 3-40<br />
ASB-2040-24 ASB-2040-24-BL-TP 3-40<br />
ASB-2040-24-BL ASB-2040-24-BL-TP 3-40<br />
ASB-2448-46 ASB-2448-46-BL-TP 3-40<br />
ASB-2448-46-BL ASB-2448-46-BL-TP 3-40<br />
DIM-140-L-TP - -<br />
DS-2S110 - -<br />
DS-2S200-TP - -<br />
DSC-110 - -<br />
DSC-2S100 - -<br />
DSC-2S110 - -<br />
DSM-1P40 - -<br />
DSM-2E75-S - -<br />
ESEQM-240-S - -<br />
ESM-2E40-S - -<br />
ESM-2E75-S - -<br />
G-2S34-TP G-2C34-TP 6-4<br />
G-2S86-TP - -<br />
GC-140-TP - -<br />
GC-2S40-TP - -<br />
GM-2S20-TP - -<br />
GQM-2S40-TP G-2S40-TP 3-7, 3-9 to 11<br />
GSC-2S110-TP G-2S110-TP 3-16, 3-17<br />
GSC-2S200 - -<br />
GSM-2E75-S-TP G-2E75-S-TP 3-22, 3-23<br />
H-140 L-140-F-TP 3-25, 26, 29, 36<br />
H-1Q16-TP - -<br />
HD-140 DIM-140-H-TP 3-12<br />
HM-140-TP R-140-TP 3-7, 3-9 3-10<br />
HM-2SP15 HM-2SP20-TP 3-27, 3-28<br />
HM-3P20 RL-3SP20-TP 3-27, 3-28<br />
HQM-1P40 R-140-TP 3-7, 3-9 to 10<br />
Discontinued<br />
Catalog<br />
Number<br />
Current<br />
Catalog<br />
Number<br />
Page<br />
No.<br />
HQM-2S40 R-2S40-TP 3-7, 3-9 to 11<br />
L-132 L-140-F-TP 3-25, 26, 29, 36<br />
LC-4-8-C LC-4-9-C 3-24<br />
LO-14-20-C LC-14-20-C 3-25, 3-26<br />
LO-1Q16-TP - -<br />
LO-4-8-C LC-4-9-C 3-24<br />
LQ-2S40 R-2S40-TP 3-7, 3-9 to 11<br />
LQF-140 - -<br />
MSM-175-S - -<br />
MT-2S200-TP - -<br />
MTM-2E75-S - -<br />
R-1S32-TP R-1P32-TP 3-5, 3-6<br />
R-22-32-TP RS-22-32-TP-W 3-30<br />
R-2E75-S-TP-AC R-2E75-S-TP 3-22, 3-23<br />
R-2E75-S-TP-MC R-2E75-S-TP 3-22, 3-23<br />
R-2Q18-4P-TP-BLS - -<br />
R-2Q18-4P-TP-W - -<br />
R-2Q26-4P-TP-BLS - -<br />
R-2Q26-4P-TP-W - -<br />
R-2S32-TP R-2P32-TP 3-5, 3-6<br />
R-2S40-TP-AC R-2S40-TP 3-7, 3-9 to 11<br />
R-2S40-TP-MC R-2S40-TP 3-7, 3-9 to 11<br />
R-2S65-TP ICN-2S86 1-65<br />
R-2S86-TP ICN-2S86 1-65<br />
R-32-40-TP RS-32-40-TP-W 3-30<br />
RC-140-TP - -<br />
RC-160-(FO or RO) RC-2S85-FO 3-38<br />
RC-160-TP RS-110-TP 3-13 to 3-17<br />
RC-180 - -<br />
RC-1P40-TP - -<br />
RC-2S102-RO RC-2S102-FO 3-39<br />
RC-2S110 R-2S110-TP 3-16, 3-17<br />
RC-2S110-RO RC-2S110-FO 3-38<br />
RC-2S200-(FO or RO) RS-2S200-FO 3-39<br />
RC-2S40-TP - -<br />
RC-2S85-RO RC-2S85-FO 3-38<br />
RC-2SP40-TP - -<br />
RC-3S150-TP - -<br />
RC-3S200-TP - -<br />
RC-4S155 - -<br />
RH-2S200 RS-2S200-TP 3-18, 3-19<br />
RK-134-TP - -<br />
RK-2S40-TP RK-2S34-TP 1-68<br />
RK-3S34-TP - -<br />
RLC-140 RL-140-TP 3-8, 3-10, 3-30<br />
RLCS-140 RLCS-140-TP-W 3-30<br />
RLM-2SP20 RL-2SP20-TP 3-27, 3-28<br />
RLQ-122-TP RLQS-122-TP-W 3-30<br />
RLQC-1100-CW - -<br />
RLQC-140 RL-140-TP 3-8, 3-10, 3-30<br />
RLQCS-140 RLCS-140-TP-W 3-30<br />
RM-140-TP R-140-TP 3-7, 3-9 to 10<br />
RM-2S40-TP R-2S40-TP 3-7, 3-9 to 11<br />
RQB-2S102 RC-2S102-TP 3-18, 3-19<br />
RQC-102-(FO or RO) RC-2S102-FO 3-39<br />
RQC-102-CW RC-2S102-TP 3-18, 3-19<br />
RQC-1100-CW - -<br />
RQC-2S100-CW - -<br />
RQC-2S102-(FO or RO) RC-2S102-FO 3-39<br />
RQC-2S102-CW RC-2S102-TP 3-18, 3-19<br />
RQC-3S60-CW RC-4S60-TP 3-13 to 3-16<br />
RQC-3S85-CW RC-4S60-TP 3-13 to 3-16<br />
RQM-2S40-TP R-2S40-TP 3-7, 3-9 to 11<br />
RS-110-(FO or RO) RC-2S85-FO 3-38<br />
RS-160-TP RS-110-TP 3-13 to 3-17<br />
RS-2S110-(FO or RO) RS-2S110-FO 3-39<br />
RS-2S110-TP R-2S110-TP 3-16, 3-17<br />
RS-2S40-TP R-2S40-TP 3-7, 3-9 to 11<br />
RS-2S60-TP RC-2S85-TP 3-13 to 3-17<br />
RS-2S80 - -<br />
RS-2S85 RC-2S85-TP 3-13 to 3-17<br />
RS-2S85-(FO or RO) RC-2S85-FO 3-38<br />
RS-3P40-TP - -<br />
Discontinued<br />
Catalog<br />
Number<br />
Current<br />
Catalog<br />
Number<br />
Page<br />
No.<br />
RSC-2S155-TP RC-2S200-TP 3-18, 3-19<br />
RSC-4S60 RC-4S60-TP 3-13 to 3-16<br />
RSD-140 - -<br />
RSH-115 HM-1P20-TP 3-27, 3-28<br />
RSH-120 HM-1P20-TP 3-27, 3-28<br />
RSH-180 - -<br />
RSH-1D40 - -<br />
RSH-215 HM-2SP20-TP 3-27, 3-28<br />
RSH-220 HM-2SP20-TP 3-27, 3-28<br />
RSH-225-F - -<br />
RSH-248-S SM-2E51-S-TP 3-20<br />
RSH-2E75-S R-2E75-S-TP 3-22, 3-23<br />
RSHM-130 L-140-F-TP 3-25, 26, 29, 36<br />
RSHM-140-TP R-140-TP 3-7, 3-9 to 10<br />
RSHM-175-S RSM-175-S-TP 3-22, 3-23<br />
RSHM-230-TP R-2SP30-TP 3-27, 3-28<br />
RSHM-240-TP R-2S40-TP 3-7, 3-9 to 11<br />
RSL-104 - -<br />
RSL-118-G - -<br />
RSL-122 LC-14-20-C 3-25, 3-26<br />
RSL-125 LC-25-TP 3-32<br />
RSL-131-G - -<br />
RSL-150 - -<br />
RSL-180 - -<br />
RSL-2232 - -<br />
RSL-225 - -<br />
S-240 R-2S40-TP 3-7, 3-9 to 11<br />
S-251-S-TP SM-2E51-S-TP 3-20<br />
S-269-S SM-2E51-S-TP 3-20<br />
S-275-S-TP RC-2E75-S-TP 3-22, 3-23<br />
S-285-TP - -<br />
SI-240-S-TP SM-2E40-S-TP 3-21<br />
SM-116-G - -<br />
SM-125-S-TP SM-151-S-TP 3-20<br />
SM-148-S SM-151-S-TP 3-20<br />
SM-225-S-TP SM-2E51-S-TP 3-20<br />
SM-233-S SM-2E51-S-TP 3-20<br />
SM-2E75-S-TP R-2E75-S-TP 3-22, 3-23<br />
TM-2E75-S-TP - -<br />
UHQM-1P40 V-140-TP 3-7, 3-9 to 10<br />
UM-140 V-140-TP 3-7, 3-9 to 10<br />
UM-1P30 VM-1P30-TP 3-8<br />
UM-2S40 V-2S40-TP 3-7, 3-9 to 11<br />
UM-2SP30 VM-2SP30-TP 3-8<br />
UQC-2S102 VC-2S102-TP 3-18, 3-19<br />
UQC-2S102-CW VC-2S102-TP 3-18, 3-19<br />
UQM-2S40 V-2S40-TP 3-7, 3-9 to 11<br />
UQM-2SP20 VM-2SP20-TP 3-27, 3-28<br />
US-110-TP VS-110-TP 3-13 to 3-17<br />
US-140 V-140-TP 3-7, 3-9 to 10<br />
US-2S110 V-S110-TP 3-16, 3-17<br />
US-2S60 VC-2S85-TP 3-13 to 3-17<br />
US-3P40 - -<br />
USC-2S200 VS-2S200-TP 3-18, 3-19<br />
USH-110 VS-110-TP 3-13 to 3-17<br />
USM-175-S VSM-175-S-TP 3-22, 3-23<br />
USM-2E40-S VSM-2E40-S-TP 3-21<br />
USM-2E75-S V-2E75-S-TP 3-22, 3-23<br />
V-2Q18-4P-TP-BLS - -<br />
V-2Q18-4P-TP-W - -<br />
V-2Q26-4P-TP-BLS - -<br />
V-2Q26-4P-TP-W - -<br />
V-2S86-TP ICN-2S86 1-65<br />
VADM-2E75-S V-2E75-S-TP 3-22, 3-23<br />
VC-160-(FO or RO) - -<br />
VC-160-TP VS-110-TP 3-13 to 3-17<br />
VC-1P40-TP - -<br />
VC-2S102-RO VC-2S102-FO 3-39<br />
VC-2S200-RO VC-2S200-FO 3-39<br />
VC-2SP40-TP - -<br />
VHQM-1P40 V-140-TP 3-7, 3-9 to 10<br />
VK-134-TP - -<br />
VK-2S40-TP VK-2S34-TP 1-68<br />
8-35<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
INDEX – FLUORESCENT BALLASTS<br />
DISCONTINUED CATALOG NUMBER TO REPLACEMENT NUMBER<br />
Electromagnetic Fluorescent<br />
Discontinued<br />
Catalog<br />
Number<br />
Current<br />
Catalog<br />
Number<br />
Page<br />
No.<br />
VK-3S34-TP - -<br />
VM-140-TP V-140-TP 3-7, 3-9 to 10<br />
VM-2S40-TP V-2S40-TP 3-7, 3-9, 3-11<br />
VM-2SP15 VM-2SP20-TP 3-27, 3-28<br />
VQB-2S102 VC-2S102-TP 3-18, 3-19<br />
VQC-1100-CW - -<br />
VQC-2S100-CW - -<br />
VQC-2S102-(FO or RO) VC-2S102-FO 3-39<br />
VQC-2S102-CW VC-2S102-TP 3-18, 3-19<br />
VQM-2S40-TP V-2S40-TP 3-7, 3-9 to 11<br />
VS-110-(FO or RO) - -<br />
VS-140-TP V-140-TP 3-7, 3-9, 3-10<br />
VS-160-TP VS-110-TP 3-13 to 3-17<br />
VS-2S110-(FO or RO) VC-2S110-FO 3-38<br />
VS-2S110-TP V-2S110-TP 3-16, 3-17<br />
VS-2S200-RO VS-2S200-FO 3-39<br />
VS-2S40-TP V-2S40-TP 3-7, 3-9-3-11<br />
VS-2S60-TP VC-2S85-TP 3-13 to 3-17<br />
VS-2S85 VC-2S85-TP 3-13 to 3-17<br />
VS-2S85-(FO or RO) - -<br />
VS-3P40 - -<br />
VSH-240 - -<br />
VSH-240-S VSM-2E40-S-TP 3-21<br />
VSH-275-S-TP VC-2E75-S-TP 3-22, 3-23<br />
VSH-285 - -<br />
VSH-2E75-S V-2E75-S-TP 3-22, 3-23<br />
VSHM-125-S - -<br />
VSHM-140 V-140-TP 3-7, 3-9 to 10<br />
VSL-108-F-TP - -<br />
VSM-140-S - -<br />
VSM-225-S - -<br />
VSM-2E75-S-TP V-2E75-S-TP 3-22, 3-23<br />
XHQM-1P40-TP X-140-TP 6-3, 6-4<br />
XT-2E57-S-TP - -<br />
YQC-2S102-TP - -<br />
YSC-2S200-TP - -<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-36
INDEX – FLUORESCENT BALLASTS<br />
REFERENCE<br />
MATERIALS<br />
DISCONTINUED CATALOG NUMBER TO REPLACEMENT NUMBER<br />
High Frequency <strong>Electronic</strong> Fluorescent<br />
Discontinued<br />
Catalog<br />
Number<br />
Suggested<br />
Replacement<br />
Catalog Number<br />
Page<br />
No.<br />
GDC-132-TP …. ….<br />
GDC-140-TP …. ….<br />
GDC-2S32-TP …. ….<br />
GDC-2S40-TP …. ….<br />
GIC-132-TP GEL-2P32-LW 1-45, 49, 54, 55, 59<br />
GIC-140-TP …. ….<br />
GIC-2S32-TP GEL-2P32-SC 1-45, 48, 49, 54,<br />
55, 58, 59<br />
GIC-2S40-TP GEL-2S40-RH-TP 1-66, 1-67<br />
IZT-1T42-M2-BS* IZT-2S26-M5-BS 2-12<br />
IZT-1T42-M2-LD* IZT-2S26-M5-LD 2-12<br />
IZT-2Q26-M2-BS* IZT-2S26-M5-BS 2-12<br />
IZT-2Q26-M2-LD* IZT-2S26-M5-LD 2-12<br />
IZT-2T42-M3-BS* IZT-2T42-M5-BS 2-12<br />
IZT-2T42-M3-LD* IZT-2T42-M5-LD 2-12<br />
RCN-132-MC ICN-132-MC 1-41, 1-44, 1-54, 1-58<br />
RCN-1P32 ICN-1P32-SC 1-44, 1-48, 1-54, 1-58<br />
RCN-1P32-SC ICN-1P32-SC 1-44, 1-48, 1-54, 1-58<br />
RCN-1S28* ICN-2S28 1-41<br />
RCN-1S40-SC REL-1S40-SC 1-66, 1-67<br />
RCN-2M32-MC ICN-2M32-MC 1-41, 45, 49, 55, 59<br />
RCN-2P32 ICN-2P32-SC 1-44, 45, 48, 49,<br />
54, 55, 58, 1-59, 62<br />
RCN-2P32-LW ICN-2P32-LW-SC 1-44, 45, 48, 49,<br />
54, 55, 59, 62<br />
RCN-2P32-SC ICN-2P32-SC 1-44, 45, 48, 49,<br />
54, 1-55, 58, 59, 62<br />
RCN-2P54-SC ICN-2S54 1-34, 36, 37,<br />
42, 43, 6-6<br />
RCN-2S28* ICN-2S28 1-41<br />
RCN-2S32-LW ICN-2P32-LW-SC 1-44, 45, 48, 49,<br />
54, 55, 59, 62<br />
RCN-2S40 REL-2S40-SC 1-66, 1-67<br />
RCN-2S40-SC REL-2S40-SC 1-66, 1-67<br />
RCN-2S86 ICN-2S86 1-65<br />
RCN-3P32 ICN-3P32-SC 1-45, 46, 49, 50,<br />
55, 56, 59, 60, 62<br />
RCN-3P32-LW-SC ICN-3P32-LW-SC 1-45, 46, 49, 50,<br />
55, 56, 59, 60, 62<br />
RCN-3P32-SC ICN-3P32-SC 1-45, 46, 49, 50,<br />
55, 56, 59, 60, 62<br />
RCN-4P32 ICN-4P32-SC 1-46, 47, 50, 51,<br />
56, 57, 60, 61, 63<br />
RCN-4P32-LW-SC ICN-4P32-LW-SC 1-46, 47, 50, 51,<br />
56, 57, 60, 61, 63<br />
RCN-4P32-SC ICN-4P32-SC 1-46, 47, 50, 51,<br />
56, 57, 60, 61, 63<br />
RDC-132-TP IZT-132-SC 2-15, 2-16<br />
RDC-140-TP …. ….<br />
RDC-2BS40-TP IZT-2TTS40-SC 2-13<br />
RDC-2S32-TP IZT-2S32-SC 2-15, 2-16<br />
RDC-2S40-TP …. ….<br />
RDC-3S32-TP IZT-3S32-SC 2-15, 2-16<br />
RDC-3S40-TP …. ….<br />
REL-1P32-RH-TP REL-1P32-SC 1-44, 48, 54, 58<br />
REL-1S32-RH-TP RCN-1S32-SC 1-44, 48, 54, 58<br />
REL-1S40-RH-TP REL-1S40-SC 1-66, 1-67<br />
REL-1S40-TP REL-1S40-SC 1-66, 1-67<br />
REL-1T32 ICF-2S26-H1-LD 1-28, 31, 32, 34, 38<br />
REL-1T42 ICF-2S26-H1-LD 1-28, 31, 32, 34, 38<br />
REL-2P32-HL-RH-TP REL-2P32-HL-SC 1-45, 48, 49, 54,<br />
55, 58, 59, 62<br />
REL-2P32-LW-RH-TP REL-2P32-LW-SC 1-45, 49, 54, 55,<br />
58, 59, 62<br />
REL-2P32-RH-TP REL-2P32-SC 1-45, 48, 49, 54,<br />
55, 58, 59, 6-6<br />
REL-2P50-SC …. ….<br />
REL-2P59-HL …. ….<br />
REL-2P75-S-RH-TP REL-2P60-S 1-68<br />
REL-2P75-S-TP REL-2P60-S 1-68<br />
REL-2Q18 ICF-2S18-H1-LD 1-27, 30, 38<br />
REL-2Q26 ICF-2S26-H1-LD 1-28, 31, 32, 34, 38<br />
REL-2S32-LW-RH-TP REL-2P32-LW-SC 1-45, 49, 54, 55,<br />
58, 59, 62<br />
REL-2S32-RH-TP RCN-2S32-SC 1-45, 49, 55, 59<br />
REL-2S40-RH-TP REL-2S40-SC 1-66, 1-67<br />
REL-2S40-TP REL-2S40-SC 1-66, 1-67<br />
REL-3P32-HL REL-3P32-HL-SC 1-46, 49, 50, 55,<br />
56, 59, 60, 62<br />
REL-3P32-LW-RH-TP REL-3P32-LW-SC 1-46, 49, 50, 55,<br />
56, 59, 60, 62<br />
REL-3P32-RH-TP REL-3P32-SC 1-46, 49, 50, 55,<br />
High Frequency <strong>Electronic</strong> Fluorescent<br />
Discontinued<br />
Catalog<br />
Number<br />
* These ballasts will be phased out during 2004 and their replacements will be available accordingly.<br />
Suggested<br />
Replacement<br />
Catalog Number<br />
Page<br />
No.<br />
56, 59, 60, 62, 6-6<br />
REL-3P32-TP REL-3P32-SC 1-46, 49, 50, 55,<br />
56, 59, 60, 62, 6-6<br />
REL-3S32-LW-RH-TP REL-3P32-LW-SC 1-46, 49, 50, 55,<br />
56, 59, 60, 62<br />
REL-3S32-RH-TP RCN-3S32-SC 1-46, 50, 56, 60<br />
REL-3S40-TP REL-3S40-RH-TP 1-66, 1-67<br />
REL-4P32 REL-4P32-SC 1-47, 50, 51, 56,<br />
57, 60, 61, 63, 6-6<br />
REL-4P32-2LS - -<br />
REL-4P32-LW-RH-TP REL-4P32-LW-SC 1-46, 47, 50, 51,<br />
56, 57, 60, 61, 63<br />
REL-4P32-RH-TP REL-4P32-SC 1-47, 50, 51, 56,<br />
57, 60, 61, 63, 6-6<br />
REL-4P32-TP REL-4P32-SC 1-47, 50, 51, 56,<br />
57, 60, 61, 63, 6-6<br />
REZ-132 REZ-132-SC 2-10<br />
REZ-1T32 REZ-1T42-M2-LD-K 2-7<br />
REZ-1T42 REZ-1T42-M2-LD-K 2-7<br />
REZ-1TTS40 REZ-1TTS40-SC 2-8<br />
REZ-2Q26 REZ-2Q26-M2-LD-K 2-7<br />
REZ-2S32 REZ-2S32-SC 2-10<br />
REZ-2TTS40 REZ-2TTS40-SC 2-8<br />
REZ-3S32 REZ-3S32-SC 2-10<br />
REZ-C1200-A …. ….<br />
REZ-C500-1 …. ….<br />
RIC-132 IIC-132-SC 1-44, 48, 54, 58<br />
RIC-132-TP IIC-132-SC 1-44, 48, 54, 58<br />
RIC-140-TP REL-1S40-SC 1-66, 1-67<br />
RIC-2S32 IIC-2S32-SC 1-45, 49, 55, 59<br />
RIC-2S32-TP IIC-2S32-SC 1-45, 49, 55, 59<br />
RIC-2S40-TP REL-2S40-SC 1-66, 1-67<br />
RIC-3S32 IIC-2S32-SC 1-45, 49, 55, 59<br />
RIC-3S32-TP IIC-2S32-SC 1-45, 49, 55, 59<br />
RIC-3S40-TP REL-3S40-RH-TP 1-66, 1-67<br />
RZT-132 IZT-132-SC 2-15, 2-16<br />
RZT-1TTS40 RZT-1TTS40-SC 2-8<br />
RZT-2S32 IZT-2S32-SC 2-15, 2-16<br />
RZT-2TTS40 IZT-2TTS40-SC 2-13<br />
RZT-3S32* IZT-3S32-SC 2-15, 2-16<br />
VCN-132-MC ICN-132-MC 1-41, 44, 54, 58<br />
VCN-1P32 ICN-1P32-SC 1-44, 48, 54, 58<br />
VCN-1P32-SC ICN-1P32-SC 1-44, 48, 54, 58<br />
VCN-1S28* ICN-2S28 1-41<br />
VCN-1S40-SC VEL-1S40-SC 1-66, 1-67<br />
VCN-2M32-MC ICN-2M32-MC 1-41, 45, 49, 55, 59<br />
VCN-2P32 ICN-2P32-SC 1-44, 45, 48, 49,<br />
54, 55, 58, 59, 62<br />
VCN-2P32-LW ICN-2P32-LW-SC 1-44, 45, 48, 49,<br />
54, 55, 58, 59, 62<br />
VCN-2P32-SC ICN-2P32-SC 1-44, 45, 48, 49,<br />
54, 55, 58, 59, 62<br />
VCN-2P54-SC ICN-2S54 1-34, 36, 37,<br />
42, 43, 6-6<br />
VCN-2S28* ICN-2S28 1-41<br />
VCN-2S32-LW ICN-2P32-LW-SC 1-44, 45, 48, 49,<br />
54, 55, 58, 59, 62<br />
VCN-2S40 REL-2S40-SC 1-66, 1-67<br />
VCN-2S40-SC VEL-2S40-SC 1-66, 1-67<br />
VCN-2S86 ICN-2S86 1-65<br />
VCN-3P32 ICN-3P32-SC 1-45, 46, 49, 50,<br />
55, 56, 59, 60, 62<br />
VCN-3P32-LW-SC ICN-3P32-LW-SC 1-45, 46, 49, 50,<br />
55, 56, 59, 60, 62<br />
VCN-3P32-SC ICN-3P32-SC 1-45, 46, 49, 50,<br />
55, 56, 59, 60, 62<br />
VCN-4P32 ICN-4P32-SC 1-46, 47, 50, 51,<br />
56, 57, 60, 61, 63<br />
VCN-4P32 VCN-4P32-SC 1-47, 51, 57, 61<br />
VCN-4P32-LW-SC ICN-4P32-LW-SC 1-46, 47, 50, 51,<br />
56, 57, 60, 61, 63<br />
VCN-4P32-SC ICN-4P32-SC 1-46, 47, 50, 51,<br />
56, 57, 60, 61, 63<br />
VDC-132-TP IZT-132-SC 2-15, 2-16<br />
VDC-140-TP …. ….<br />
VDC-2BS40-TP IZT2TTS40 2-13<br />
VDC-2S32-TP IZT-2S32-SC 2-15, 2-16<br />
VDC2S40-TP …. ….<br />
VDC-3S32-TP IZT-3S32 2-15, 2-16<br />
VDC-3S40-TP …. ….<br />
VEL-175-S-TP VEL-2P75-S 1-68<br />
VEL-1P32-RH-TP VEL-1P32-SC 1-44, 48, 54, 58<br />
VEL-1S32-RH-TP VCN-1S32-SC 1-44, 48, 54, 58<br />
Note: In some cases, replacement may have different dimensions, specifications, starting method, lamps<br />
supported or wiring configurations. Technical specifications of the replacement should be evaluated for<br />
intended application.<br />
High Frequency <strong>Electronic</strong> Fluorescent<br />
Discontinued<br />
Catalog<br />
Number<br />
Discontinued<br />
Catalog<br />
Number<br />
Suggested<br />
Replacement<br />
Catalog Number<br />
Suggested<br />
Replacement<br />
Catalog Number<br />
Page<br />
No.<br />
VEL-1S40-RH-TP VEL-1S40-SC 1-66, 1-67<br />
VEL-1S40-TP VEL-1S40-SC 1-66, 1-67<br />
VEL-1T32 ICF-2S26-H1-LD 1-28, 31, 32, 34, 38<br />
VEL-1T42 ICF-2S26-H1-LD 1-28, 31, 32, 34, 38<br />
VEL-2E75-S-TP VEL-2P75-S 1-68<br />
VEL-2P32-HL-RH-TP VEL-2P32-HL-SC 1-45, 48, 49, 54,<br />
55, 58, 59, 62<br />
VEL-2P32-LW-RH-TP VEL-2P32-LW-SC 1-45, 49, 54, 55,<br />
58, 59, 62<br />
VEL-2P32-RH-TP VEL-2P32-SC 1-45, 48, 49, 54,<br />
55, 58, 59,<br />
VEL-2P50-SC …. ….<br />
VEL-2P59-HL - -<br />
VEL-2Q18 ICF-2S18-H1-LD 1-27, 1-30, 1-38<br />
VEL-2Q26 ICF-2S26-H1-LD 1-28, 31, 32, 34, 38<br />
VEL-2S32-LW-RH-TP VEL-2P32-LW.SC 1-45, 49, 54, 55,<br />
58, 59, 62<br />
VEL-2S32-RH-TP VCN-2S32-SC 1-45, 1-49, 1-55<br />
1-59<br />
VEL-2S40-RH-TP VEL-2S40-SC 1-66, 1-67<br />
VEL-2S40-TP VEL-2S40-SC 1-66, 1-67<br />
VEL-3P32-HL VEL-3P32-HL-SC 1-46, 49, 50, 55,<br />
56, 59, 60, 62<br />
VEL-3P32-LW-RH-TP VEL-3P32-LW-SC 1-45, 46, 49, 50,<br />
55, 56, 59, 60, 62<br />
VEL-3P32-RH-TP VEL-3P32-SC 1-46, 49, 50, 55,<br />
56, 59, 60, 62<br />
VEL-3P32-TP VEL-3P32-SC 1-46, 49, 50, 55,<br />
56, 59, 60, 62<br />
VEL-3S32-LW-RH-TP VEL-3P32-LW-SC 1-45, 46, 49, 50,<br />
55, 56, 59, 60, 62<br />
VEL-3S32-RH-TP VCN-3S32-SC 1-46, 50, 56, 60<br />
VEL-3S40-TP VEL-3S40-RH-TP 1-66, 1-67<br />
VEL-4P32-2LS - -<br />
VEL-4P32-LW-RH-TP VEL-4P32-LW-SC 1-46, 47, 50, 51,<br />
56, 57, 60, 61, 63<br />
VEL-4P32-RH-TP VEL-4P32-SC 1-47, 50, 51, 56,<br />
57, 60, 61, 63<br />
VEL-4P32-TP VEL-4P32-SC 1-47, 50, 51, 56,<br />
57, 60, 61, 63<br />
VEZ-132 VEZ-132-SC 2-10<br />
VEZ-1T32 VEZ-1T42-M2-LD-K 2-7<br />
VEZ-1T42 VEZ-1T42-M2-LD-K 2-7<br />
VEZ-1TTS40 VEZ-1TTS40-SC 2-8<br />
VEZ-2Q26 VEZ-2Q26-M2-LD-K 2-7<br />
VEZ-2S32 VEZ-2S32-SC 2-10<br />
VEZ-2TTS40 VEZ-2TTS40-SC 2-8<br />
VEZ-3S32 VEZ-2S32-SC 2-10<br />
VEZ-C1200-A …. ….<br />
VEZ-C500-1 …. ….<br />
VIC-132 IIC-132-SC 1-44, 48, 54, 58<br />
VIC-132-TP IIC-132-SC 1-44, 48, 54, 58<br />
VIC-140-TP VEL-1S40-SC 1-66, 1-67<br />
VIC-2S32 IIC-2S32-SC 1-45, 49, 55, 59<br />
VIC-2S32-TP IIC-2S32-SC 1-45, 49, 55, 59<br />
VIC-2S40-TP VEL-2S40-SC 1-66, 1-67<br />
VIC-3S32 IIC-2S32-SC 1-45, 49, 55, 59<br />
VIC-3S32-TP IIC-2S32-SC 1-45, 49, 55, 59<br />
VIC-3S40-TP VEL-3S40-RH-TP 1-66, 1-67<br />
VZT-132 IZT-132-SC 2-15, 2-16<br />
VZT-1TTS40-SC VZT-1TTS40-SC 2-8<br />
VZT-2S32 IZT-2S32-SC 2-15, 2-16<br />
VZT-2TTS40-SC IZT-2TTS40-SC 2-13<br />
VZT-3S32* IZT-3S32-SC 2-15, 2-16<br />
VZT-4S32-4 IZT-4S32 2-15, 2-16<br />
VZT-4S32-8 IZT-4S32 2-15, 2-16<br />
Low Frequency <strong>Electronic</strong> Fluorescent<br />
Page<br />
No.<br />
GK-2S110-TP … ….<br />
RK-134-TP …. ….<br />
RK-2S110-TP …. ….<br />
RK-2S40-TP RK-2S34-TP 1-67<br />
RK-3S34-TP …. ….<br />
VK-134-TP …. ….<br />
VK-2S40-TP VK-2S34-TP 1-67<br />
8-37<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
INDEX – HID BALLASTS<br />
DISCONTINUED CATALOG NUMBER TO REPLACEMENT NUMBER<br />
HID HID HID<br />
Obsolete<br />
Catalog<br />
Numbers<br />
Suggested<br />
Replacement<br />
Catalog Number<br />
Page<br />
No.<br />
Alternate<br />
Quadri-volt<br />
120/208/240/277V<br />
71A0201 71A0280 5-46 ….<br />
71A0401-791 .... .... ....<br />
71A0410 71A0490 5-46 71A0490<br />
71A0430 71A0490 5-46 71A0490<br />
71A0440 71A04F0 5-46 ….<br />
71A0450 71A0490 5-46 71A0490<br />
71A04D0 71A0490/04F0 5-46 ….<br />
71A0540 71A05F0 5-47 ….<br />
71A0550 71A0590 5-47 71A0590<br />
71A0560 71A0590 5-47 71A0590<br />
71A05D0 71A0590/05F0 5-47 ….<br />
71A0740 71A07F0 5-47 ….<br />
71A0750 71A0790 5-47 71A0790<br />
71A0760 71A0790 5-47 71A0790<br />
71A07D0 71A0790/07F0 5-47 ….<br />
71A1500 71A1580 5-14 ....<br />
71A1510 .... .... ....<br />
71A1530 71A1580 5-14 ....<br />
71A1540 .... .... ....<br />
71A15R0 .... .... ....<br />
71A1810 .... .... ....<br />
71A1820 .... .... ....<br />
71A1830 71A1580(CWA)** 5-14 ....<br />
71A2020 .... .... ....<br />
71A20R0 .... .... ....<br />
71A2300 71A2303 5-14 ....<br />
71A2310 .... .... ....<br />
71A2320 .... .... ....<br />
71A2330 71A2080(CWA)** 5-14 ....<br />
71A2340 .... .... ....<br />
71A2500 71A2501 5-14 71A2571/91<br />
71A2502 71A2501 5-14 71A2571/91<br />
71A2510 71A2571/91 5-14 71A2571/91<br />
71A2512 71A2571/91 5-14 71A2571/91<br />
71A2520 .... .... 71A2571/91<br />
71A2522 .... .... 71A2571/91<br />
71A2530 71A2571/91 5-14 71A2571/91<br />
71A2531 71A2571/91 5-14 71A2571/91<br />
71A2532 71A2571/91 5-14 71A2571/91<br />
71A2540 71A2541 5-14 ....<br />
71A2542 71A2541 5-14 ....<br />
71A2551 .... .... 71A2571/91<br />
71A2561 .... .... 71A2571/91<br />
71A25D1 71A25A1<br />
5-14 71A2571/91<br />
(120/240/347V)<br />
(120/277/347V)<br />
71A25J1 .... .... ....<br />
71A25R1 71A25N1 5-15 ....<br />
71A2801 71A2800 5-14 ....<br />
71A2803 71A2800 5-14 ....<br />
71A2810 .... .... 71A2571/91(CWA)**<br />
71A2820 .... .... 71A2571/91(CWA)**<br />
71A2840 71A2541(CWA)** 5-14 ....<br />
71A29G0 .... .... ....<br />
71A3000 71A3002 5-15 71A3072/92<br />
71A3001 71A3002 5-15 71A3072/92<br />
71A3010 .... .... 71A3072/92<br />
71A3011 .... .... 71A3072/92<br />
71A3012 .... .... 71A3072/92<br />
71A3020 .... .... 71A3072/92<br />
71A3021 .... .... 71A3072/92<br />
71A3022 .... .... 71A3072/92<br />
71A3030 71A3072/92<br />
5-5,<br />
5-15<br />
71A3072/92<br />
Obsolete<br />
Catalog<br />
Numbers<br />
Suggested<br />
Replacement<br />
Catalog Number<br />
71A3031 71A3072/92<br />
71A3032 71A3072/92<br />
Page<br />
No.<br />
5-5,<br />
5-15<br />
5-5,<br />
5-15<br />
Alternate<br />
Quadri-volt<br />
120/208/240/277V<br />
71A3072/92<br />
71A3072/92<br />
71A3040 71A3042 5-15 ....<br />
71A3041 71A3042 5-15 ....<br />
71A3052 .... .... 71A3072/92<br />
71A3062 .... .... 71A3072/92<br />
71A30J2 .... .... ....<br />
71A3140 71A3042 5-15 ....<br />
71A3150 .... .... 71A3072/92<br />
71A3320 .... .... 71A3072/92(CWA)**<br />
71A3330 71A3072/92(CWA)** 5-15 ....<br />
71A3340 71A3042(CWA)** 5-15 ....<br />
71A3500 71A3502 5-16 71A3572/92<br />
71A3501 71A3502 5-16 71A3572/92<br />
71A3510 .... .... 71A3572/92<br />
71A3520 .... .... 71A3572/92<br />
71A3521 .... .... 71A3572/92<br />
71A3522 .... .... 71A3572/92<br />
71A3530 .... .... 71A3572/92<br />
71A3531 .... .... 71A3572/92<br />
71A3532 .... .... 71A3572/92<br />
71A3540 71A3542 5-16 ....<br />
71A3541 71A3542 5-16 ....<br />
71A3552 71A3572/92 5-16 71A3572/92<br />
71A3562 71A3572/92 5-16 71A3572/92<br />
71A35J2 .... .... ....<br />
71A35R2 71A57N0 6-16 ....<br />
71A3640 71A3542 5-16 ....<br />
71A3650 .... .... 71A3572/92<br />
71A3800 71A3502(CWA)** 5-16 71A3572/92(CWA)**<br />
71A3810 .... .... 71A3572/92(CWA)**<br />
71A3820 .... .... 71A3572/92(CWA)**<br />
71A3825-791 .... .... ....<br />
71A3830 .... .... 71A3572/92(CWA)**<br />
71A3840 71A3542(CWA)** 5-16 ....<br />
71A4000 .... .... 71A4071/91<br />
71A4001 .... .... 71A4071/91<br />
71A4020 .... .... 71A4071/91<br />
71A4021 .... .... 71A4071/91<br />
71A4030 .... .... 71A4071/91<br />
71A4031 .... .... 71A4071/91<br />
71A4040 71A4041 5-17 ....<br />
71A4051 71A4071/91 5-17 71A4071/91<br />
71A4061 71A4071/91 5-17 71A4071/91<br />
71A40J1 .... .... ....<br />
71A40R1 71A60N1 6-16 ....<br />
71A4142 71A4041 5-17 71A4071/91<br />
71A4152 .... .... 71A4071/91<br />
71A4310 .... .... ....<br />
71A4320 .... .... ....<br />
71A4401 .... .... 71A4071/91(CWA)**<br />
71A4411 .... .... 71A4071/91(CWA)**<br />
71A4421 .... .... 71A4071/91(CWA)**<br />
71A4431 .... .... 71A4071/91(CWA)**<br />
71A4441 71A4041(CWA)** 5-17 71A4071/91(CWA)**<br />
71A5000 .... .... 71A5070/90<br />
71A5005 71A5005-P 5-18 ....<br />
71A5030* .... .... 71A5070/90<br />
71A5037 71A5037-P 5-18 ....<br />
71A5037-B 71A5037-BP 5-18 ....<br />
71A5050 .... .... 71A5070/90<br />
Obsolete<br />
Catalog<br />
Numbers<br />
Suggested<br />
Replacement<br />
Catalog Number<br />
Page<br />
No.<br />
Alternate<br />
Quadri-volt<br />
120/208/240/277V<br />
71A5060 .... .... 71A5070/90<br />
71A5090 71A5070-001<br />
5-5,<br />
5-17<br />
71A5102 .... .... 71A5070/90<br />
71A5105 71A5105-P 5-18 ....<br />
71A5122 .... .... 71A5070/90<br />
71A5137 71A5137-P 5-18 ....<br />
71A5137-B 71A5137-BP 5-18 ....<br />
71A5142 71A5040 5-17 ....<br />
71A5205 71A5205-P 5-19 ....<br />
71A5227 (Reactor) .... .... 71A5292 (3x4 Core)<br />
71A5228 .... .... ....<br />
71A5229 (Reactor) .... .... 71A5292 (3x4 Core)<br />
71A5237 71A5237-P 5-19 ....<br />
71A5237-B 71A5237-BP 5-19 ....<br />
71A5288 .... .... ....<br />
71A5289<br />
.... .... 71A5292 (3x4 Core)<br />
(Reactor + Transformer)<br />
71A52C2 71A52A2 5-19 71A5292 (3x4 Core)<br />
71A5337 71A5337-P 5-20 ....<br />
71A5337-B 71A5337-BP 5-20 ....<br />
71A5338 .... .... ....<br />
71A5386 .... .... ....<br />
71A5387<br />
.... .... 71A5390 (3x4 Core)<br />
(Reactor + Transformer)<br />
71A5388 .... .... ....<br />
71A53C0 71A53A0 5-20 71A5390 (3x4 Core)<br />
71A5427 (Reactor) .... .... 71A5490 (3x4 Core)<br />
71A5428 (Reactor) .... .... 71A5490 (3x4 Core)<br />
71A5429 (Reactor) .... .... 71A5492 (3x4 Core)<br />
71A5437 71A5437-P 5-21 ....<br />
71A5437-B 71A5437-BP 5-21 ....<br />
71A5488<br />
.... .... 71A5490 (3x4 Core)<br />
(Reactor + Autotransformer)<br />
71A5489<br />
.... .... 71A5492 (3x4 Core)<br />
(Reactor + Autotransformer)<br />
71A5510 71A5570/90 5-22 71A5570/90<br />
71A5520 71A5570/90 5-22 71A5570/90<br />
71A5550 71A5570/90 5-22 71A5570/90<br />
71A5560 71A5570/90 5-22 71A5570/90<br />
71A5592 71A5593 5-22 71A5593<br />
71A55A2 71A55A3 5-22 ....<br />
71A55B0 71A55A0 5-22 ....<br />
71A55D0 71A55A0<br />
5-22 71A5570/90<br />
(120/240/347V)<br />
(120/240/347V)<br />
71A55G0 71A55H0 5-22 ....<br />
71A55J0 71A55H0 5-22 ....<br />
71A55R0 71A55N0 6-16 ....<br />
71A5710 71A5770/90 5-6 71A5770/90<br />
71A5711 71A5771/91<br />
5-6,<br />
5-24<br />
71A5771/91<br />
71A5720 71A5770/90 5-6 71A5770/90<br />
71A5721 71A5771/91<br />
5-6,<br />
5-24<br />
71A5771/91<br />
71A5750 .... .... 71A5770/90<br />
71A5760 .... .... 71A5770/90<br />
71A5793 71A5792 5-25 71A5792<br />
71A57A3 71A57A2 5-25 ....<br />
71A57D0 71A57A0<br />
5-24 71A5770/90<br />
(120/240/347V)<br />
(120/240/347V)<br />
71A57J0 71A55H0 5-22 ....<br />
71A57R0 71A57N0 6-16 ....<br />
71A5843-T 71A5842-T 5-26 ....<br />
* Availability limited to existing stocks.<br />
** The CWA ballasts offered as replacements are furnished with a capacitor which must be used in<br />
the ballast circuit as shown in the wiring diagram in this <strong>Atlas</strong>. The original ballast circuit in the<br />
lighting fixture may have been low or normal power factor, and therefore, no capacitor was used.<br />
If the CWA ballast with its capacitor does not fit in the fixture, contact <strong>Advance</strong> for assistance.<br />
<strong>Advance</strong> Replacement ballasts shown are functionally equivalent to listed obsolete ballasts.<br />
Dimensional differences can exist.<br />
Suffix “T” ballast catalog numbers indicate ballast is equipped with 120V output tap. Standard practice<br />
is to use 120V tap on quadri-volt ballast, where quadri-volt ballasts are available.<br />
Where no replacement ballast is shown, ballast has been discontinued and inventories are exhausted.<br />
Consult nearest <strong>Advance</strong> sales office for assistance.<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-38
INDEX – HID BALLASTS<br />
DISCONTINUED CATALOG NUMBER TO REPLACEMENT NUMBER<br />
HID HID HID<br />
Obsolete<br />
Catalog<br />
Numbers<br />
Suggested<br />
Replacement<br />
Catalog Number<br />
Page<br />
No.<br />
Alternate<br />
Quadri-volt<br />
120/208/240/277V<br />
71A5893 71A5892 5-26 71A5892<br />
71A58A3 71A58A2 5-26 ....<br />
71A58N3 71A58N2 6-16 ....<br />
71A5942-T 71A5943-T 5-26 ....<br />
71A5992 71A5993 5-26 71A5993<br />
71A59A2 71A59A3 5-26 ....<br />
71A59N2 71A59N3 6-16 ....<br />
71A6000 71A6001 5-27 71A6071/91<br />
71A6010 71A6071/91<br />
5-6,<br />
5-27<br />
71A6071/91<br />
71A6011 71A6071/91<br />
5-6,<br />
5-27<br />
71A6071/91<br />
71A6020 71A6021 5-26 71A6071/91<br />
71A6021 71A6071/91<br />
5-6,<br />
5-27<br />
71A6071/91<br />
71A6030 71A6031 5-27 71A6071/91<br />
71A6040 71A6041 5-27 71A6071/91<br />
71A6043-T 71A6042-T 5-28 ....<br />
71A6061 71A6071/91<br />
5-6,<br />
5-27<br />
71A6071/91<br />
71A6084 (120/277V) 71A6004 (120V) 5-26 71A6034 (277V)<br />
71A6093 71A6092 5-28 71A6092<br />
71A60A3 71A60A2 5-28 ....<br />
71A60B1 71A60A1(120/277/347V) 5-27 ....<br />
71A60D1 71A60A1<br />
5-27 71A6071/91<br />
(120/240/347V)<br />
(120/277/347V)<br />
71A60J1 71A60H1 5-27 ....<br />
71A60N3 71A60N2 6-16 ....<br />
71A60R1 71A60N1 6-16 ....<br />
71A6300 (Series) 71A6382(ILO) 5-28 ....<br />
71A6310 (Series) .... .... ....<br />
71A6320 (Series) .... .... ....<br />
71A6330 (Series) 71A6382-001D(ILO) 5-6 ....<br />
71A6340 (Series) 71A6382-001D(ILO) 5-6 ....<br />
71A6342 71A6342-001D 5-6 ....<br />
71A6352 (120/240V) 71A6382-001D(120V) 5-6 ....<br />
71A6382 71A6382-001D 5-6 ....<br />
71A63J2 .... .... ....<br />
71A6500 71A6502 5-30 71A6572/92<br />
71A6501 71A6502 5-30 71A6572/92<br />
71A6510 71A6572/92 5-30 71A6572/92<br />
71A6511 71A6572/92 5-30 71A6572/92<br />
71A6512 71A6572/92 5-30 71A6572/92<br />
71A6520 71A6572/92 5-30 71A6572/92<br />
71A6521 71A6572/92 5-30 71A6572/92<br />
71A6522 71A6572/92 5-30 71A6572/92<br />
71A6530 71A6532 5-30 71A6572/92<br />
71A6531 71A6532 5-30 71A6572/92<br />
71A6540 71A6542 5-30 ....<br />
71A6541 71A6542 5-30 ....<br />
71A6551 71A6572/92 5-30 71A6572/92<br />
71A6561 71A6572/92 5-30 71A6572/92<br />
71A6571 71A6572 5-30 71A6572/92<br />
71A65B2 71A65A2(120/277/347V) 5-30 ....<br />
71A65D2(120/240/347V) 71A65A2 5-30 ....<br />
71A65E3 71A6593<br />
5-29 71A6593<br />
(120/240/347V)<br />
(120/240/347V)<br />
71A65F3<br />
(277/347/480V)<br />
71A65F3-T<br />
(347/480V/120T)<br />
5-29 ....<br />
71A65M6 .... .... ....<br />
71A65R2 71A65N2 6-16 ....<br />
71A6700 71A6702 5-31 71A6772/92<br />
Obsolete<br />
Catalog<br />
Numbers<br />
Suggested<br />
Replacement<br />
Catalog Number<br />
Page<br />
No.<br />
Alternate<br />
Quadri-volt<br />
120/208/240/277V<br />
71A6701 71A6702 5-31 71A6772/92<br />
71A6710 71A6772/92<br />
5-6,<br />
5-31<br />
71A6772/92<br />
71A6711 71A6772/92<br />
5-6,<br />
5-31<br />
71A6772/92<br />
71A6712 71A6772/92<br />
5-6,<br />
5-31<br />
71A6772/92<br />
71A6720 71A6722/92 5-31 71A6772/92<br />
71A6721 71A6722/92 5-31 71A6772/92<br />
71A6722 71A6722/92 5-31 71A6772/92<br />
71A6730 71A6732 5-31 71A6772/92<br />
71A6731 71A6732 5-31 71A6772/92<br />
71A6740 71A6742 5-31 ....<br />
71A6771 71A6772<br />
5-6,<br />
5-31<br />
71A6772/92<br />
71A6791 71A6792 5-31 71A6772/92<br />
71A67D2 71A67A2<br />
5-31 71A6772/92<br />
(120/240/347V)<br />
(120/277/347V)<br />
71A68J0 .... .... ....<br />
71A7900 71A7950 5-35 ....<br />
71A7910* .... .... ....<br />
71A7920 71A7950 5-35 ....<br />
71A7956 71A79E6(120/208/240V) 5-35 ....<br />
71A7960 (240/480V) 71A7950 (120/240V) 5-35 71A7940*(480V)<br />
71A79D1 71A79A1<br />
(120/240/347V) (120/277/347)<br />
5-34 71A7971/91<br />
71A8000 71A8050/80 5-37 ....<br />
71A8030 71A8080 5-37 ....<br />
71A8056 71A80E6 (120/277/347) 5-37 ....<br />
71A8060(240/480V) .... .... 71A8040(480V)<br />
71A80D1<br />
(120/240/347V)<br />
71A80A1<br />
(120/277/347V)<br />
5-36 71A8071/91<br />
71A80R1 71A79N1,71A80N1 6-17 ....<br />
71A8106* .... .... 71A8176/96<br />
71A8111 .... .... 71A8176/96<br />
71A8116* .... .... 71A8176/96<br />
71A8130 71A8180 5-39 ....<br />
71A8131 71A8176/96<br />
5-7,<br />
5-38<br />
71A8176/96<br />
71A8136 71A8176/96<br />
5-7,<br />
5-38<br />
71A8176/96<br />
71A8141 .... .... ....<br />
71A8151 .... .... 71A8176/96<br />
71A8156 71A81E6(120/208/240V) 5-39 ....<br />
71A81D2 71A81A2<br />
5-38 71A8172/92<br />
(120/240/347V)<br />
(120/277/347V)<br />
71A81R2 71A81N2 6-17 ....<br />
71A8211 71A8271/91 5-41 71A8271/91<br />
71A8221 71A8271/91 5-41 71A8271/91<br />
71A8230 71A8280 5-41 ....<br />
71A8250 (120/240V) .... .... 71A8220 (240V)<br />
71A8256 71A82E6(120/208/240V) 5-41 ....<br />
71A8260 (240/480V) .... .... 71A8240 (480V)<br />
71A8294<br />
(120/208/240/277V)<br />
71A8280 (120/277V)<br />
71A8210 (208V)<br />
5-41 71A8220 (240V)<br />
71A82B1 71A82A1(120/277/347V) 5-41 ....<br />
71A82D1 71A82A1<br />
5-41 71A8271/91<br />
(120/240/347V)<br />
(120/277/347V)<br />
71A82R1 71A82N1 6-17 ....<br />
71A8311 .... .... 71A8371/91<br />
71A8321 .... .... 71A8371/91<br />
71A8331 .... .... 71A8371/91<br />
Obsolete<br />
Catalog<br />
Numbers<br />
Suggested<br />
Replacement<br />
Catalog Number<br />
Page<br />
No.<br />
Alternate<br />
Quadri-volt<br />
120/208/240/277V<br />
71A8401 71A8403 5-43 71A8473/93<br />
71A8402 71A8403 5-43 71A8473/93<br />
71A8411 71A8473/93 5-43 71A8473/93<br />
71A8412 71A8473/93 5-43 71A8473/93<br />
71A8413 71A8473/93 5-43 71A8473/93<br />
71A8420 71A8450 5-43 ....<br />
71A8421 71A8473/93 5-43 71A8473/93<br />
71A8422 71A8473/93 5-43 71A8473/93<br />
71A8423 71A8473/93 5-43 71A8473/93<br />
71A8430 71A8480 5-43 ....<br />
71A8431 71A8433 5-43 71A8473/93<br />
71A8432 71A8433 5-43 71A8473/93<br />
71A8441 71A8443 5-43 ....<br />
71A8442 71A8443 5-43 ....<br />
71A8456 71A84E6(120/208/240V) 5-43 ....<br />
71A8471 .... .... 71A8473/93<br />
71A8472 .... .... 71A8473/93<br />
71A8482 .... .... 71A8473/93<br />
71A8484 71A8480 5-43 ....<br />
71A8491 .... .... 71A8473/93<br />
71A8492 .... .... 71A8473/93<br />
71A84D3 71A84A3<br />
5-43 71A8473/93<br />
(120/240/347V)<br />
(120/277/347V)<br />
71A84R2 71A84N3 6-17 ....<br />
71A8540 71A85F5 5-44 ....<br />
71A8590 71A85E5<br />
5-44<br />
71A85F5<br />
(120/208/240/277V) (120/208/240V) (277/347/480)<br />
71A85A3 .... .... ....<br />
71A8741 71A8743 5-45 ....<br />
71A8771 71A8773/93 5-45 71A8773/93<br />
71A8791 71A8773/93 5-45 71A8773/93<br />
71A87D3 71A87A3<br />
5-45 71A8773/93<br />
(120/240/347V)<br />
(120/277/347V)<br />
71A8900 .... .... 71A8970/90<br />
71A8930 .... .... 71A8970/90<br />
71A8931 .... .... 71A8991<br />
71A8984 (120/277V) 71A8954 (120V) 5-40 71A8970/90 (CWA)<br />
71A9068 .... .... 71A4071/91<br />
71A9073 .... .... 71A5070/90<br />
71A9074 71A5040 5-18 ....<br />
71A9082 .... .... 71A4071/91<br />
71A9114 .... .... ....<br />
71A9115 71A40R1<br />
5-9,<br />
5-17<br />
....<br />
71A9116 71A65N2 6-16 ....<br />
71A9124 .... .... 71A4071/91<br />
71A9127 .... .... 71A5070/90<br />
71A9135 .... .... 71A3072/92<br />
71A9136 .... .... 71A3072/92<br />
71A9137 .... .... 71A3072/92<br />
71A9138 71A3072/92<br />
5-5,<br />
5-15<br />
71A3072/92<br />
71A9139 71A3042 5-15 ....<br />
71A9189 71A0590 5-47 ....<br />
71A9192 71A0490 5-46 ....<br />
71A9209 71A5580 5-22 71A5570/90<br />
71A9212 71A6382-001D 5-6 ....<br />
71A9240 .... .... 71A3572/92<br />
71A9242 .... .... 71A5570/90<br />
71A9243 71A5540 5-22 ....<br />
71A9263 .... .... 71A3572/92<br />
71A9278 71A25N1 6-15 ....<br />
REFERENCE<br />
MATERIALS<br />
* Availability limited to existing stocks.<br />
** The CWA ballasts offered as replacements are furnished with a capacitor which must be used in<br />
the ballast circuit as shown in the wiring diagram in this <strong>Atlas</strong>. The original ballast circuit in the<br />
lighting fixture may have been low or normal power factor, and therefore, no capacitor was used.<br />
If the CWA ballast with its capacitor does not fit in the fixture, contact <strong>Advance</strong> for assistance.<br />
<strong>Advance</strong> Replacement ballasts shown are functionally equivalent to listed obsolete ballasts. Dimensional<br />
differences can exist.<br />
Suffix “T” ballast catalog numbers indicate ballast is equipped with 120V output tap. Standard practice<br />
is to use 120V tap on quadri-volt ballast, where quadri-volt ballasts are available.<br />
Where no replacement ballast is shown, ballast has been discontinued and inventories are exhausted.<br />
Consult nearest <strong>Advance</strong> sales office for assistance.<br />
8-39<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
INDEX – HID BALLASTS<br />
DISCONTINUED CATALOG NUMBER TO REPLACEMENT NUMBER<br />
HID HID HID<br />
Obsolete<br />
Catalog<br />
Numbers<br />
71A9279<br />
Suggested<br />
Replacement<br />
Catalog Number<br />
71A35R2<br />
Page<br />
No.<br />
5-11,<br />
5-16<br />
Alternate<br />
Quadri-volt<br />
120/208/240/277V<br />
71A9280 71A55N0 6-16 71A9281<br />
71A9282 71A65N2 6-16 ....<br />
71A9301 71A07F0 5-47 ....<br />
71A9302 .... .... 71A6071/91<br />
71A9303 .... .... 71A6071/91<br />
71A9305 .... .... 71A6572/92<br />
71A9306 .... .... 71A4071/91<br />
71A9312 .... .... 71A4071/91<br />
71A9313 .... .... 71A4071/91<br />
71A9314 .... .... 71A4071/91<br />
71A9315 .... .... 71A4071/91<br />
71A9316 71A4041 5-17 ....<br />
71A9317 71A0790 5-47 71A0750<br />
71A9318 71A0790 5-47 71A0760<br />
71A9319 .... .... 71A4071/91<br />
71A9326 71A07F0 5-47 ....<br />
71A9327 71A04F0 5-46 ....<br />
71A9328 71A05F0 5-47 ....<br />
71A9331 .... .... 71A2571/91<br />
71A9332 .... .... 71A2571/91<br />
71A9334 .... .... 71A3572/92<br />
71A9335 .... .... ....<br />
71A9341 71A0590 5-47 71A0560<br />
71A9352 71A3002 (CWA)** 5-15 71A3072/92<br />
71A9355 71A0790 5-47 71A0760<br />
71A9356 71A0590 5-47 71A0560<br />
71A9357 71A0490 5-46 71A0410<br />
71A9359 71A0490 5-46 71A0430<br />
71A9366 71A4041(CWA)** 5-17 ....<br />
71A9377* .... .... ....<br />
71A9378* .... .... ....<br />
71A9416 71A3592 5-16 71A3572/92<br />
71A9417 71A3072<br />
5-5,<br />
5-15<br />
71A3572/92<br />
71A9418 71A3092 5-15 71A3572/92<br />
71A9424 71A65A2 5-30 ....<br />
71A9426 71A57N0 6-16 ....<br />
71A9429 71A82N1 6-17 ....<br />
71A9430 71A84N3 6-17 ....<br />
71A9432 (240/480V) 71A4041(480V) 5-17 71A4071/91(240V)<br />
71A9437 (240/480V) 71A5040 (480V) 5-18 71A5070/90 (240V)<br />
71A9441 71A87R3 6-17 ....<br />
71A9445 71A0450 5-46 ....<br />
71A9446 .... .... ....<br />
71A9449 .... .... ....<br />
71A9451 71A82H1 5-41 ....<br />
71A9452 71A84H3 5-43 ....<br />
71A9462 71A81R6 6-17 ....<br />
71A9465 71A67R2 6-16 ....<br />
71A9467 71A0201 5-49 ....<br />
71A9468 71A4071/91 5-17 71A4071/91<br />
71A9469 71A4091 5-17 71A4071/91<br />
71A9470 .... .... ....<br />
71A9471 .... .... ....<br />
71A9473 71A25N1 6-15 ....<br />
71A9474 71A29R0 6-15 ....<br />
71A9475 .... .... ....<br />
71A9476 71A35R2 5-49 ....<br />
71A9477 71A40R1 5-49 ....<br />
71A9478 71A65N2 6-16 ....<br />
....<br />
Obsolete<br />
Catalog<br />
Numbers<br />
Suggested<br />
Replacement<br />
Catalog Number<br />
Page<br />
No.<br />
Alternate<br />
Quadri-volt<br />
120/208/240/277V<br />
71A9479 71A55N0 6-16 ....<br />
71A9480 71A57N0 6-16 ....<br />
71A9481 71A60N1 6-16 ....<br />
71A9482 71A65N2 6-16 ....<br />
71A9483 71A67R2 6-16 ....<br />
71A9484 71A79N1 6-17 ....<br />
71A9485 71A80N1 6-17 ....<br />
71A9486 71A81N2 6-17 ....<br />
71A9487 71A81R6 6-17 ....<br />
71A9489 71A82N1 6-17 ....<br />
71A9491 71A84N3 6-17 ....<br />
71A9492 70A87R3 .... ....<br />
71A9494 71A78R1 6-17 ....<br />
71A9502 (240/480V) 71A8241(480V) 5-41 71A8271/91 (240V)<br />
71A9519 .... .... ....<br />
71A9520 71A3542 (CWA)** 5-16 ....<br />
71A9521 71A4041(CWA)** 5-17 ....<br />
71A9522 71A7941 5-34 ....<br />
71A9523 71A8041 5-36 ....<br />
71A9524 .... .... ....<br />
71A9525 .... .... ....<br />
71A9526 71A07F0 5-47 ....<br />
71A9530 .... .... 71A4071/91<br />
71A9532 .... .... ....<br />
71A9533 .... .... ....<br />
71A9534 .... .... ....<br />
71A9545 71A8107 5-38 ....<br />
71A9546 71A8007 5-36 ....<br />
71A9547 71A7907 5-34 ....<br />
71A9590 .... .... 71A8176/96<br />
71A9597 .... .... ....<br />
71A9646 71A0280 5-46 ....<br />
71A9696 .... .... ....<br />
71A9720 71A60H1 5-27 ....<br />
71A9722 71A55H0 5-22 ....<br />
71A9733 .... .... ....<br />
71A9734 71A79J1 5-34 ....<br />
71A9735 71A80J1 5-36 ....<br />
71A9737 71A87J3 5-45 ....<br />
71A9740-2T .... .... ....<br />
71A9745-2T .... .... ....<br />
71A9748* .... .... ....<br />
71A9761 71A65J2 5-30 ....<br />
71A9775 .... .... ....<br />
71A9784 71A57H0 5-24 ....<br />
71A9787 .... .... ....<br />
71A9789 71A80J1 5-36 ....<br />
71A9791 .... .... ....<br />
71A980 (120/277V) 71A7950 (120/240V) 5-35 71A7930 (277V)<br />
71A9808* .... .... ....<br />
71A9814 .... .... ....<br />
72C9156 72C4083-N-P 5-56 ....<br />
72C9159 72C4083-N-P 5-56 ....<br />
72C9160 72C3584-N-P 5-56 ....<br />
72C9163 72C3584-N-P 5-56 ....<br />
72C9164 72C3084-N-P 5-56 ....<br />
72C9167 72C3084-N-P 5-56 ....<br />
72C9168 72C2584-N-P 5-56 ....<br />
72C9171 72C2584-N-P 5-56 ....<br />
72C9221 72C2584-N-P 5-56 ....<br />
72C9222 72C3084-N-P 5-56 ....<br />
72C9223 72C3584-N-P 5-56 ....<br />
Obsolete<br />
Catalog<br />
Numbers<br />
Suggested<br />
Replacement<br />
Catalog Number<br />
Page<br />
No.<br />
Alternate<br />
Quadri-volt<br />
120/208/240/277V<br />
72C9224 72C4083-N-P 5-56 ....<br />
72E5005-NP IMH50ALF 4-5 ....<br />
72E5005-NP-BLS IMH50ABLS 4-5 ....<br />
73B5580 73B5590 5-61 73B5590<br />
73B5780 73B5790 5-62 73B5790<br />
73B6081 73B6091 5-62 73B6091<br />
73B7705 .... .... ....<br />
74P1831-011 .... .... ....<br />
74P2321-011 .... .... ....<br />
78E3542-001 .... ....<br />
78E4300 (Series) .... .... ....<br />
78E4310 (Series) .... .... ....<br />
78E4320 (ILO) .... .... ....<br />
78E4330 (Series) .... .... ....<br />
78E4340 (Series) .... .... ....<br />
78E5040-001 .... .... ....<br />
78E5090-001 .... .... ....<br />
78E6300 (Series) .... .... ....<br />
78E6310 (Series) .... .... ....<br />
78E6320 (Series) .... .... ....<br />
78E6330 (Series) .... .... ....<br />
78E6340 (Series) .... .... ....<br />
78E6351* .... .... ....<br />
78E8391 .... .... ....<br />
78E8492 78E8493 5-68 ....<br />
799501-001 .... .... ....<br />
79W3140 .... .... ....<br />
79W3150 79W3092 5-69 ....<br />
79W3640 79W3542 5-69 ....<br />
79W3650 79W3592 5-69 ....<br />
79W4300 (Series) 79W6351(ILO) 5-70 ....<br />
79W4320 (Series) 79W6351(ILO) 5-70 ....<br />
79W4330 (Series) .... .... ....<br />
79W4340 (Series) 79W6341(ILO) 5-70 ....<br />
79W6300 (Series) 79W6351(ILO) 5-70 ....<br />
79W6310 (Series) .... .... ....<br />
79W6320 (Series) 79W6351(ILO) 5-70 ....<br />
79W6330 (Series) .... .... ....<br />
79W6340 (Series) 79W6341(ILO) 5-70 ....<br />
79W6381* .... .... ....<br />
79W6541 79W6542 5-70 ....<br />
79W6591 79W6592 5-70 ....<br />
79W8463 (240/480V) 79W8443 (480V) 5-71 79W8493 (240V)<br />
79W8492 79W8493 5-71 ....<br />
79W9256 79W6351 5-70 ....<br />
79W9499* .... .... ....<br />
79W9500 (240/480V) 79W8192 (240V) 5-71 ....<br />
79W9501* .... .... ....<br />
79W9502 (240/480V) 79W8241 (480V) 5-71 79W8291 (240V)<br />
79W9503 (240/480V) 79W8443 (480V) 5-71 79W8493 (240V)<br />
* Availability limited to existing stocks.<br />
** The CWA ballasts offered as replacements are furnished with a capacitor which must be used in<br />
the ballast circuit as shown in the wiring diagram in this <strong>Atlas</strong>. The original ballast circuit in the<br />
lighting fixture may have been low or normal power factor, and therefore, no capacitor was used.<br />
If the CWA ballast with its capacitor does not fit in the fixture, contact <strong>Advance</strong> for assistance.<br />
<strong>Advance</strong> Replacement ballasts shown are functionally equivalent to listed obsolete ballasts. Dimensional<br />
differences can exist.<br />
Suffix “T” ballast catalog numbers indicate ballast is equipped with 120V output tap. Standard practice<br />
is to use 120V tap on quadri-volt ballast, where quadri-volt ballasts are available.<br />
Where no replacement ballast is shown, ballast has been discontinued and inventories are exhausted.<br />
Consult nearest <strong>Advance</strong> sales office for assistance.<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-40
INDEX – HID BALLASTS<br />
DISCONTINUED CATALOG NUMBER TO REPLACEMENT NUMBER<br />
IGNITORS<br />
Obsolete<br />
Catalog<br />
Numbers<br />
Suggested<br />
Replacement<br />
Catalog Number<br />
Page<br />
No.<br />
LI500 LI501-H4 5-53, 54 ....<br />
LI501-A LI501-H4 5-51,53,54,55 ....<br />
LI501-B5 LI501-H4 5-53, 54 ....<br />
LI501-E LI501-J4 5-53 ....<br />
LI505-H4 (Cut-off) LI501-H4 (Std.) 5-53 ....<br />
LI520-H5 LI522-H5 5-51 ....<br />
LI521-H5 LI522-H5 5-51 ....<br />
LI525-H6 (Cut-off) LI522-H5 (Std.) 5-51 ....<br />
LI530-H5 LI533-H4 5-51 ....<br />
LI531-H5 LI533-H4 5-51 ....<br />
LI532-H4 LI533-H4 5-51 ....<br />
LI533-H4A LI533-H4 5-51 ....<br />
LI540-H4 Consult Factory for Availability<br />
LI550 LI551-H4 5-53 ....<br />
LI551-B5 LI551-H4 5-53 ....<br />
LI551-RS .... .... ....<br />
LI555-H4 (Cut-off) LI551-H4 (Std.) 5-53 ....<br />
LI560-H5 LI561-H5 5-51 ....<br />
LI570 LI571-H5 5-51, 53, 54 ....<br />
Alternate<br />
Quadri-volt<br />
120/208/240/277V<br />
* Availability limited to existing stocks.<br />
** The CWA ballasts offered as replacements are furnished with a capacitor which must be used in<br />
the ballast circuit as shown in the wiring diagram in this <strong>Atlas</strong>. The original ballast circuit in the<br />
lighting fixture may have been low or normal power factor, and therefore, no capacitor was used.<br />
If the CWA ballast with its capacitor does not fit in the fixture, contact <strong>Advance</strong> for assistance.<br />
<strong>Advance</strong> Replacement ballasts shown are functionally equivalent to listed obsolete ballasts. Dimensional<br />
differences can exist.<br />
Suffix “T” ballast catalog numbers indicate ballast is equipped with 120V output tap. Standard practice<br />
is to use 120V tap on quadri-volt ballast, where quadri-volt ballasts are available.<br />
Where no replacement ballast is shown, ballast has been discontinued and inventories are exhausted.<br />
Consult nearest <strong>Advance</strong> sales office for assistance.<br />
REFERENCE<br />
MATERIALS<br />
8-41<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109
COMPACT FLUORESCENT LAMP REFERENCE GUIDE<br />
Lamp<br />
Type<br />
Twin<br />
Tube<br />
Quad<br />
Tube<br />
Triple<br />
Tube<br />
2D<br />
Flat<br />
Tube<br />
Twin<br />
Tube<br />
Quad<br />
Tube<br />
Triple<br />
Tube<br />
2D<br />
Long<br />
Twin<br />
Tube<br />
Lamp<br />
Watts<br />
NEMA Lamp<br />
Designation<br />
PHILIPS<br />
GE<br />
OSRAM/<br />
SYLVANIA<br />
PANASONIC<br />
2-Pin lamps with built-in starter<br />
5W CFT5W/G23 PL-S5W F5BX CF5DS - 3-31, 33<br />
7W CFT7W/G23 PL-S7W F7BX CF7DS - 3-31, 33<br />
9W CFT9W/G23 PL-S9W F9BX CF9DS - 3-31, 33<br />
13W CFT13W/GX23 PL-S13W F13BX CF13DS - 3-31, 34<br />
9W CFQ9W/G23 - F9DBX23T4 CF9DD - 3-31, 33<br />
10W CFQ10W/G24d - - - - -<br />
13W CFQ13W/GX23 PL-C13W/USA F13DBX23T4 CF13DD FDS13/2 3-31, 34<br />
13W CFQ13W/G24d PL-C13W F13DBXT4 - - 3-34<br />
16W CFQ15W/GX32d - - - - -<br />
18W CFQ18W/G24d PL-C18W F18DBXT4 CF18DD FDS18/2 3-35<br />
22W CFQ20W/GX32d PL-C15MM/22W - - FDL22 3-32, 35<br />
26W CFQ26W/G24d PL-C26W F26DBXT4 CF26DD FDS26/2 3-32, 35<br />
28W CFQ27W/GX32d PL-C15MM/28W - - FDL28 3-32, 35<br />
13W CFTR13W/GX24d - - - - -<br />
18W CFTR18W/GX24d - - CF18DT - 3-35<br />
26W CFTR26W/GX24d - - CF26DT - 3-35<br />
16W CFS16W/GR8 - - - - -<br />
28W CFS28W/GR8 - F28 2D - - 3-36<br />
4-Pin lamps<br />
18W CFM18W/2G10 - - CF18DF - -<br />
24W CFM24W/2G10 - - CF24DF - -<br />
36W CFM36W/2G10 - - CF36DF - -<br />
5W CFT5W/2G7 - - CF5DS/E - -<br />
7W CFT7W/2G7 - - CF7DS/E - 1-26<br />
9W CFT9W/2G7 - - CF9DS/E - 1-26<br />
13W CFT13W/2GX7 - - CF13DS/E - -<br />
10W CFQ10W/G24q - - - FDS10/4 -<br />
13W CFQ13W/G24q PL-C13W/4P F13DBX/4P CF13DD/E FDS13/4 1-27<br />
18W CFQ18W/G24q PL-C18W/4P F18DBX/4P CF18DD/E FDS18/4 1-28<br />
26W CFQ26W/G24q PL-C26W/4P F26DBX/4P CF26DD/E - 1-28<br />
13W CFTR13W/GX24q - F13TBX/4P CF13DT/E - 1-29<br />
18W CFTR18W/GX24q PL-T18W F18TBX/4P CF18DT/E FHT18 1-30<br />
26W CFTR26W/GX24q PL-T26W F26TBX/4P CF26DT/E FHT26 1-31<br />
32W CFTR32W/GX24q PL-T32W F32TBX/4P CF32DT/E FHT32 1-31<br />
42W CFTR42W/GX24q PL-T42W F42TBX/4P CF42DT/E - 1-32<br />
57W CFTR57W/GX24q - F57QBX/4P CF57DT/E - 1-32<br />
60W PL-H60W/4P - - - 1-33<br />
70W CFTR70W/GX24q - F70QBX/4P - - 1-32<br />
85W PL-H85W/4P - - - 1-33<br />
120W PL-H120W/4P - - - 1-33<br />
10W CFS10W/GR10q - F10 2D/4P - - 1-38<br />
16W CFS16W/GR10q - F16 2D/4P - - 1-38<br />
21W CFS21W/GR10q - F21 2D/4P - - 1-38<br />
28W CFS28W/GR10q - F28 2D/4P - - 1-39<br />
38W CFS38W/GR10q - F38 2D/4P - - 1-39<br />
55W CFS55W/GRY10q - F55 2D/4P - - -<br />
18W FT18W/2G11 PL-L18W F18BX FT18DL - 3-32<br />
18W FT18W/2G11/RS - F18BX/RS FT18DL/RS - 1-34<br />
24-27W FT24W/2G11 PL-L24W F27BX/RS FT24DL - 1-34<br />
36-39W FT36W/2G11 PL-L36W F39BX/RS FT36DL - 1-34<br />
40W FT40W/2G11/RS PL-L40W F40BX FT40DL/RS - 1-35<br />
50W FT50W/2G11/RS PL-L50W F50BX/RS - - 1-36<br />
55W FT55W/2G11 PL-L55W F55BX FT55DL - 1-37<br />
80W FT80W/2G11 PL-L80W - - - 1-37<br />
Page<br />
No.<br />
REFERENCE<br />
MATERIALS<br />
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 8-42