24.11.2014 Views

Sunrise – the beginning of a brand new day

Sunrise – the beginning of a brand new day

Sunrise – the beginning of a brand new day

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Sunrise</strong> – <strong>the</strong> <strong>beginning</strong> <strong>of</strong> a <strong>brand</strong> <strong>new</strong> <strong>day</strong><br />

__________________________________________________________________________________________________________<br />

<strong>Sunrise</strong> – <strong>the</strong> <strong>beginning</strong> <strong>of</strong> a <strong>brand</strong> <strong>new</strong> <strong>day</strong><br />

Choosing a <strong>new</strong> chamber should be easy – you already<br />

know what you want. Angelantoni Industrie is now<br />

<strong>of</strong>fering <strong>the</strong> most complete standard line <strong>of</strong> chambers<br />

available through a single manufacturer. What is <strong>new</strong> for<br />

us are <strong>the</strong> features and innovations. What is <strong>new</strong> for you<br />

is being able to find exactly what you want, quickly and<br />

easily.<br />

New and Improved Features<br />

- Completely <strong>new</strong> door system for ease <strong>of</strong> access and<br />

confident closing<br />

- New steam generator system for humidity systems<br />

- New touchscreen control panel<br />

- Our highest reliability ever<br />

Models and Styles<br />

BASIC series: (both climatic and T only), -40°C with single stage compressor or -70°C with cascade refrigeration,<br />

standard temperature change rate<br />

BENCH-TOP version: 16 or 60 liters (T only) and 160 liters (both climatic and T only)<br />

E series: Energy saving version (climatic), for lower testing performances: T range -20/+180°C, change rates <strong>of</strong> less<br />

than 2°C per minute<br />

ES series: Environmental screening version (both climatic and T only) with higher testing performances: -40°C with<br />

single stage compressor or -70°C with cascade refrigeration, temperature change rates <strong>of</strong> up to 5°C per minute<br />

ESS series: “Speedy” version (both climatic and T only): -70°C with cascade refrigeration, temperature change rates <strong>of</strong><br />

up to 15°C per minute<br />

DEWPPY series: (climatic) with a different RH control, based on a bath <strong>the</strong>rmoregulated at dew point for more precise<br />

humidity regulation<br />

V series: (climatic) – biomedical version: two models (700 - 1500 l) for tests at steady state conditions with very no<br />

need for fast T change rates<br />

Size in<br />

liters<br />

Basic<br />

16 60 160 250 300 340 500 600 700 1000 1200 1400 1500 1600 2000*<br />

Benchtop<br />

E<br />

ES<br />

ESS<br />

Dewppy<br />

V<br />

* 2000 l chambers are available also with 2000 mm dim. in height or width<br />

= Climatic models for Temperature and Relative humidity tests<br />

= Thermostatic models for only Temperature tests<br />

___________________________________________________________________________________________________________________ page 2


<strong>Sunrise</strong> – <strong>the</strong> <strong>beginning</strong> <strong>of</strong> a <strong>brand</strong> <strong>new</strong> <strong>day</strong><br />

__________________________________________________________________________________________________________<br />

<strong>Sunrise</strong><br />

at a glance!<br />

1. Heated inspection window:<br />

a fully transparent double heating film allows <strong>the</strong><br />

test compartment to be easily and clearly inspected<br />

and prevents condensation from forming on <strong>the</strong><br />

glass.<br />

2 Double ceiling:<br />

prevents any condensation drop from falling onto<br />

<strong>the</strong> specimen.<br />

3 Axial fan:<br />

it allows a better distribution <strong>of</strong> air and helps<br />

specimens adapt to temperature variations.<br />

4 Wheels:<br />

<strong>the</strong>y allow <strong>the</strong> chamber to be easily moved<br />

5 Rounded corners:<br />

<strong>the</strong>y allow a better drainage <strong>of</strong> condensation drops<br />

and easier cleaning.<br />

6 Water tank:<br />

for <strong>the</strong> humidification system, it is accessible by<br />

simply opening <strong>the</strong> lower door <strong>of</strong> <strong>the</strong> chamber.<br />

7 Double floor:<br />

it improves <strong>the</strong> distribution <strong>of</strong> air inside <strong>the</strong><br />

chamber.<br />

8 Locking system: <strong>new</strong> mechanical closings<br />

• Control system:<br />

consists <strong>of</strong> a PLC and "KeyKratos Plus" user<br />

interface placed on <strong>the</strong> door. In 6 languages<br />

(Italian, English, French, German, Spanish,<br />

Dutch), it allows a perfect interaction between<br />

<strong>the</strong> equipment and <strong>the</strong> user.<br />

• Dehumidifier: operates down to –20°C dew<br />

point.<br />

• Interfaces: RS232 or RS485 (on request),<br />

E<strong>the</strong>rnet port<br />

• Options:<br />

No. 4 analogic inputs + no. 4 inputs for PT100<br />

probes + no. 8 auxiliary contacts<br />

• Digital min./max. <strong>the</strong>rmostat:<br />

in case <strong>of</strong> malfunctioning, <strong>the</strong> chamber stops running<br />

• Humidity:<br />

open/close circuit for humidification water complete with mechanical filter.<br />

• Humidification system:<br />

- <strong>new</strong> humidifier with a self contained heater and dedicated controlling S/W<br />

for a better reliability.<br />

- <strong>the</strong> water tank can be fed through normal running water thanks to <strong>the</strong><br />

embedded s<strong>of</strong>tener (except for 160 l models) or through manual filling<br />

- water recycling can be activated by a button on <strong>the</strong> control panel<br />

___________________________________________________________________________________________________________________ page 3


<strong>Sunrise</strong> – <strong>the</strong> <strong>beginning</strong> <strong>of</strong> a <strong>brand</strong> <strong>new</strong> <strong>day</strong><br />

__________________________________________________________________________________________________________<br />

<strong>Sunrise</strong> overview<br />

Control and management system:<br />

controlled by PLC and "KeyKratos Plus" user interface<br />

placed on <strong>the</strong> door.<br />

• Easy use by touch screen with related pop up screen where<br />

necessary.<br />

• User friendly data input during editing, check and<br />

administration <strong>of</strong> cycle.<br />

• Memory capacity to 1000 cycles with 350 segments (on<br />

compact flash).<br />

• Messages on scheduled maintenance activities.<br />

• Recordings in CSV format (Comma Separated Value) for easy<br />

export to Excel® from Compact Flash to Pendrive via USB<br />

interface placed on <strong>the</strong> front panel (program files are easily<br />

convertible into graphic format).<br />

• A trend chart for recorded variables available with a scale from<br />

-100/+200.<br />

• Synoptic graphs for <strong>the</strong> chamber, humidity, low stage<br />

refrigeration and high stage refrigeration (Dewppy version<br />

excluded).<br />

Chamber lining:<br />

stainless steel with vapour-pro<strong>of</strong> welding (all models).<br />

Drip cap:<br />

invisibly placed under <strong>the</strong> door, it is extremely efficient.<br />

Portholes:<br />

80 mm dia. available on all models, 150 mm dia. not<br />

available for 16 l model<br />

Noise reduction system:<br />

installed in <strong>the</strong> machine compartment, it reduces <strong>the</strong><br />

chamber noise. Fur<strong>the</strong>r noise reduction may be provided<br />

upon request (with water condensation).<br />

Double ceiling and double floor:<br />

<strong>the</strong>y allow a better air distribution inside <strong>the</strong> chamber<br />

avoiding condensation or dripping over <strong>the</strong> specimen.<br />

Air treatment system:<br />

it ensures a precise control <strong>of</strong> <strong>the</strong> climatic parameters<br />

inside <strong>the</strong> chamber with minimal <strong>the</strong>rmal inertia; an axial<br />

fan allows rapid temperature variations <strong>of</strong> both air and<br />

specimen.<br />

Basic Configuration<br />

❑ ・Inspection window: multiple-crystal, with double heated<br />

transparent film, 450x450 mm size (smaller sizes for benchtop<br />

models)<br />

❑・ Self feeding system (town water through chamber<br />

embedded s<strong>of</strong>tener) not available for 160 l models<br />

❑ ・Wheels: self-pivoting wheels.<br />

❑・ Serial interface: RS232 (or RS485 on request). RS422 for<br />

star or multidrop connection to <strong>the</strong> remote control system<br />

(distances up to 15 and 1000 metres respectively).<br />

❑ ・Port hole: 80 mm diameter, fitted with rubber cap. It<br />

allows internal-external electrical, mechanical or hydraulic<br />

connections.<br />

❑・ Thermostat: max./min. digital <strong>the</strong>rmostat with independent<br />

probe<br />

❑ ・UPS connection: (<strong>the</strong> UPS is an optional accessory) it is<br />

used for <strong>the</strong> supply <strong>of</strong> <strong>the</strong> microprocessor unit in order to<br />

guarantee data storage and acquisition even in case <strong>of</strong> power<br />

failure.<br />

❑ No. 1 internal grid shelf<br />

❑ Air condenser<br />

❑ T & RH analogic retransmission<br />

❑ no. 1 auxiliary contact<br />

Refrigeration system:<br />

simple and reliable, it ensures optimum <strong>the</strong>rmodynamic<br />

performances at any temperature.<br />

Network connection:<br />

several chambers may be connected to a master PC for<br />

both local and remote centralised supervision, storage <strong>of</strong><br />

test cycles and data logging.<br />

Structure:<br />

<strong>the</strong> equipment modularity allows easy servicing and<br />

upgrades.<br />

Ergonomics:<br />

it allows easy access to <strong>the</strong> chamber wherever placed; <strong>the</strong><br />

control interface is mounted on <strong>the</strong> front panel; <strong>the</strong> water<br />

tank is easily filled from <strong>the</strong> lower front panel.<br />

Humidification system (climatic version):<br />

The <strong>new</strong> humidifier with a self contained heater and<br />

dedicated controlling S/W <strong>of</strong>fers two great advantages:<br />

• correct functioning without <strong>the</strong> need <strong>of</strong> distilled or<br />

demineralised water;<br />

• <strong>the</strong> use <strong>of</strong> ‘dry’ vapour in order to avoid condensation<br />

on <strong>the</strong> specimens and to reproduce real environmental<br />

conditions.<br />

Humidity control (climatic version): <strong>the</strong> principle <strong>of</strong> <strong>the</strong><br />

Assman psychrometer (dry bulb - wet bulb) was applied to<br />

allow <strong>the</strong> microprocessor to correctly determine relative<br />

humidity and setting parameters.<br />

Options<br />

❑ WinKratos s<strong>of</strong>tware: installed on local or remote PC (to be<br />

supplied upon request) and running under Windows 2000,<br />

XP (license included)<br />

❑ Multichamber remote control: multichamber WinKratos<br />

s<strong>of</strong>tware installed on a PC (to be supplied upon request) and<br />

connection kit for controlling several chambers (up to 16)<br />

❑<br />

from <strong>the</strong> same PC station.<br />

Noise reduction system: water-condensed, it allows a<br />

2÷4 dB (a) reduction <strong>of</strong> <strong>the</strong> chamber noise.<br />

❑・ UV lamp: to be used for ageing tests on painted surfaces,<br />

plastic materials, rubber, etc. Correct functioning is within 0<br />

and +40°C.<br />

❑・ Handling port hole: 150 mm <strong>of</strong> diameter, it is positioned<br />

on <strong>the</strong> door under <strong>the</strong> inspection window. It allows <strong>the</strong><br />

handling <strong>of</strong> specimens inside <strong>the</strong> chamber (available for<br />

models from 600 litres up).<br />

❑・ Internal shelves: AISI 304 stainless steel, adjustable in<br />

height, grid shelves to be added to <strong>the</strong> one supplied.<br />

❑・ Set <strong>of</strong> no.4 analogic inputs 0÷10V for user’s data<br />

acquisition (no. 1 set max)<br />

❑・ Set <strong>of</strong> no. 4 PT100 inputs (no. 1 set max)<br />

❑・ Set <strong>of</strong> no. 8 auxiliary contacts (no. 1 set max) ≥250 l<br />

___________________________________________________________________________________________________________________ page 4


<strong>Sunrise</strong> – <strong>the</strong> <strong>beginning</strong> <strong>of</strong> a <strong>brand</strong> <strong>new</strong> <strong>day</strong><br />

__________________________________________________________________________________________________________<br />

Control system and user’s interface<br />

❑・ Set <strong>of</strong> no. 2 auxiliary contacts (no. 1 set max) bench-top<br />

models<br />

❑・ Uninterrutible Power Supply (UPS) for PLC<br />

KeyKratos Plus Limited:<br />

Hardware<br />

4096 colours with STN tecnology.<br />

Faster control<br />

2 types <strong>of</strong> memory support for storing cycles, recordings, and<br />

alarms: Compact Flash, Internal memory<br />

S<strong>of</strong>tware<br />

• Touch menu with related pop up screens where necessary<br />

• Memory capacity to 1000 cycles with 350 segments (on<br />

compact flash)<br />

• User friendly data input during editing, check and<br />

administration <strong>of</strong> cycle.<br />

• Delayed start <strong>of</strong> <strong>the</strong> tests (hh:mm:ss)<br />

• Messages on scheduled maintenance activities<br />

• system is available in 6 languages:<br />

ITALIAN, ENGLISH, GERMAN, SPANISH, FRENCH, DUTCH<br />

PC Winkratos s<strong>of</strong>tware:<br />

WINKRATOS ® S/W package (running under Windows<br />

2000, XP, VISTA) <strong>of</strong>fers a powerful and flexible control and<br />

management system.<br />

It allows <strong>the</strong> user to:<br />

• create test programs<br />

• refer to and modify previously created test programs<br />

• delete all test programs that are no longer necessary<br />

• print any test program in text format.<br />

Main features<br />

• Connection to PLC through RS232 (RS422 if <strong>the</strong> PC must<br />

be connected to more than one chamber (up to 16, using<br />

multi-serial cards).<br />

• Colour printing on any Windows 2000, XP, VISTA<br />

compatible printer.<br />

• Multiple access password levels.<br />

Graphic functions<br />

• Fully-configurable layout <strong>of</strong> acquired measures’charts.<br />

• Display <strong>of</strong> several charts on <strong>the</strong> monitor.<br />

• Several colours to be chosen at one’s choice for <strong>the</strong><br />

display <strong>of</strong> different parameters’ curves.<br />

• Enable/disable <strong>of</strong> chart display and grids.<br />

• Real-time update <strong>of</strong> acquired measures’ charts.<br />

Acquisition functions<br />

• Real-time measurement <strong>of</strong> test parameters by means <strong>of</strong><br />

graphic cursors.<br />

• Max. flexibility for cycles to be set.<br />

• Storage <strong>of</strong> occurred events such as alarms, commands,<br />

NEW!!!<br />

• Ability to add notes on <strong>the</strong> graphs<br />

• Delayed start <strong>of</strong> <strong>the</strong> tests<br />

___________________________________________________________________________________________________________________ page 5


<strong>Sunrise</strong> – <strong>the</strong> <strong>beginning</strong> <strong>of</strong> a <strong>brand</strong> <strong>new</strong> <strong>day</strong><br />

__________________________________________________________________________________________________________<br />

etc.<br />

WINKRATOS ® may be installed on PCs supplied by ACS or<br />

belonging to <strong>the</strong> customer and may be connected to any<br />

SUNRISE chamber.<br />

• Optimized view <strong>of</strong> synoptic graphs<br />

• Two editing modes: “entry-level” and<br />

“advanced”<br />

BASIC SERIES<br />

MODEL* SU250 (C) SU340 (C) SU600 (C) SU1200 (C) SU1600 (C) SU2000 (C)<br />

FEATURES<br />

Useful capacity (litres) 224 336 557 1152 1535 2040<br />

Int. dim. mm (WxDxH) 600x535x700 600x800x700 850x733x895 1000x1130x1020 1000x1505x1020 1000x2000x1020<br />

Ext. dim. mm (WxDxH) 850x1460x1602 850x1725x1602 1100x1705x1997 1250x2160x2123 1250x2534x2143 1250x3035x2143<br />

Temperature range –40°C/+180°C –40°C/+180°C –40°C/+180°C –40°C/+180°C –40°C/+180°C –40°C/+180°C<br />

C version –75°C/+180°C –75°C/+180°C –75°C/+180°C –75°C/+180°C –75°C/+180°C –75°C/+180°C<br />

Precision over time (T) ±0,25…±0,3°C ±0,25…±0,3°C ±0,25…±0,3°C ±0,25…±0,3°C ±0,25…±0,3°C ±0,25…±0,3°C<br />

Heating Temperature Rate1 (–40/+180°C) 5°C/min 4,5°C/min 4,5°C/min 4°C/min 3°C/min 2,5°C/min<br />

C version (–70/+180°C) 5°C/min 4,5°C/min 4,5°C/min 4°C/min 3°C/min 2,5°C/min<br />

Cooling Temperature Rate 1 (+180/–40°C) 3,5°C/min 3°C/min 4°C/min 4°C/min 3°C/min 2,5°C/min<br />

C version (+180/–70°C) 2,5°C/min 2°C/min 4°C/min 3°C/min 2,5°C/min 2°C/min<br />

R.H. range (τ = –20 2 /+94°C) 10%…98% 10%…98% 10%…98% 10%…98% 10%…98% 10%…98%<br />

R.H. precision ±1%…±3% ±1%…±3% ±1%…±3% ±1%…±3% ±1%…±3% ±1%…±3%<br />

Int. dissipation T= –25°C 400W 400W 1000W 1300W 1300W 500W<br />

C version: T= –55°C 600W 500W 1200W 1500W 1500W 550W<br />

Noise dBA3 59 59 64 65 65 65<br />

C version 63 63 66 68 68 68<br />

* For temperature only versions(without R.H. control) add <strong>the</strong> suffix T.<br />

1 In compliance with IEC 60068-3-5 and IEC 60068-3-6<br />

2 Non continuous tests; +2/+94°C for continuous tests<br />

3 Measured at 1 metre from <strong>the</strong> front in free environment<br />

Performances related to standard supply, without accessories and options.<br />

BENCH-TOP version<br />

The <strong>Sunrise</strong> bench-top is <strong>the</strong> smaller size <strong>of</strong> <strong>the</strong> <strong>Sunrise</strong> series. They have <strong>the</strong> same excellent performance <strong>of</strong> <strong>the</strong> larger<br />

chambers and maintain <strong>the</strong> same electrical and SW interface in order to integrate easily with o<strong>the</strong>r ACS chambers<br />

through <strong>the</strong> WinKratos SW and remote PC.They are intended for Environmental Testing <strong>of</strong> small specimens and can be<br />

positioned on <strong>the</strong> laboratory bench or on optional dedicated trolley.<br />

The chambers are mainly dedicated for temperature tests with <strong>the</strong> possibility to choose two temperature ranges (–40°C<br />

or –70°C up to +180°C).<br />

The biggest model can be equipped with humidity control system.<br />

They can be easily installed in any laboratory thanks to <strong>the</strong> light weight <strong>of</strong> <strong>the</strong> equipment, low noise and <strong>the</strong> possibility<br />

to plug it in <strong>the</strong> 230V single phase socket.<br />

BENCH-TOP VERSION<br />

MODEL SU16 T SU60 T (C) SU160 T (C)*<br />

FEATURES<br />

Useful Capacity (l) 16 59,5 178<br />

External Dimension (WxDxH) mm 465x500x670 630x910X1160 840x1130x1420<br />

Internal Useful Dimension (WxDxH) mm 310x230x206 350x340x500 560x564x560<br />

Temperature Range -40°C/+130°C -40°C/+180°C -40°C/+180°C<br />

C Version -70°C/+180°C -70°C/+180°C<br />

Precision over time (T) ±1 ±0.25 ±0.25<br />

R.H. Range in 10°C


<strong>Sunrise</strong> – <strong>the</strong> <strong>beginning</strong> <strong>of</strong> a <strong>brand</strong> <strong>new</strong> <strong>day</strong><br />

__________________________________________________________________________________________________________<br />

ENERGY SAVING SERIES<br />

<strong>Sunrise</strong> “E” series have basic environmental performances and require simple utilities connection. They are intended for<br />

general applications when high environmental performances are not required. An ideal tool for tropical tests on<br />

pharmaceutic products (stability tests), plastic, rubber, paper, semiconductor (85/85).<br />

MODEL SU250 E SU340 E SU600 E SU1200 E SU1600 E<br />

FEATURES<br />

Useful capacity (litres) 224 336 557 1152 1535<br />

Int. dim. mm (WxDxH) 600x535x700 600x800x700 850x733x895 1000x1130x1020 1000x1505x1020<br />

Ext. dim. mm (WxDxH) 850x1460x1602 850x1725x1602 1100x1705x1997 1250x2160x2123 1250x2534x2143<br />

Temperature range –20°C/+180°C –20°C/+180°C –20°C/+180°C –10°C/+150°C – 10°C/+150°C<br />

Precision over time (T) ±0,25…±0,3°C ±0,25…±0,3°C ±0,25…±0,3°C ±0,25…±0,3°C ±0,25…±0,3°C<br />

Heating Temperature Rate 1 (0/+100°C) 1,7°C/min 1,4°C/min 1°C/min 1°C/min 0,7°C/min<br />

Cooling Temperature Rate 1 (+100/0°C) 1,7°C/min 1,4°C/min 1°C/min 0,5°C/min 0,3°C/min<br />

R.H. range (τ = +2/+84°C) 10%…95% 10%…95% 10%…95% 10%…95% 10%…95%<br />

R.H. precision ±1%…±3% ±1%…±3% ±1%…±3% ±1%…±3% ±1%…±3%<br />

Int. dissipation T= 0°C 500W 500W 500W 500W 500W<br />

Noise dBA 2 59 59 59 59 59<br />

1 In compliance with IEC 60068-3-5 and IEC 60068-3-6<br />

2 Measured at 1 metre from <strong>the</strong> front in free environment<br />

Performances related to standard supply, without accessories and options.<br />

ENVIRONMENTAL SCREENING SERIES<br />

The <strong>Sunrise</strong> “ES” series have superior environmental performances. They are intended for Environmental Stress<br />

Screening (ESS) or generally in <strong>the</strong> reliability growth processes where a 5°C/min is a must. The chambers are equipped<br />

with water condenser (remote air condenser as option).<br />

MODEL* SU250 ES (C) SU340 ES (C) SU600 ES (C) SU1200 ES (C) SU1600 ES (C)<br />

FEATURES<br />

Useful capacity (litres) 224 336 557 1152 1535<br />

Int. dim. mm (WxDxH) 600x535x700 600x800x700 850x733x895 1000x1130x1020 1000x1505x1020<br />

Ext. dim. mm (WxDxH) 850x1460x1602 850x1725x1602 1100x1705x1997 1250x2160x2123 1250x2534x2143<br />

Temperature range –40°C/+180°C –40°C/+180°C –40°C/+180°C –40°C/+180°C –40°C/+180°C<br />

C version –75°C/+180°C –75°C/+180°C –75°C/+180°C –75°C/+180°C –75°C/+180°C<br />

Precision over time (T) ±0,5…±1°C ±0,5…±1°C ±0,5…±1°C ±0,5…±1°C ±0,5…±1°C<br />

Heating Temperature Rate 1 (–40/+180°C) 10°C/min 10°C/min 6,1°C/min 7°C/min 5°C/min<br />

C version (–70/+180°C) 11,5°C/min 10°C/min 7°C/min 6,5°C/min 5,5°C/min<br />

Cooling Temperature Rate 1 (+180/–40°C) 6,1°C/min 5,5°C/min 4°C/min 5°C/min 3,5°C/min<br />

C version (+180/–70°C) 6,6°C/min 5,5°C/min 6°C/min 5,5°C/min 3,5°C/min<br />

R.H. range (τ = –20 2 /+94°C) 10%…98% 10%…98% 10%…98% 10%…98% 10%…98%<br />

R.H. precision ±2%…±5% ±2%…±5% ±2%…±5% ±2%…±5% ±2%…±5%<br />

Int. dissipation T= –25°C 1600W 1300W 2500W 3500W 2600W<br />

C version: T= –55°C<br />

2000W 1500W 3500W 4500W 3000W<br />

Noise dBA 3 60 60 66 67 67<br />

C version 65 65 68 70 70<br />

* For temperature only versions(without R.H. control) add <strong>the</strong> suffix T before ES.<br />

1 In compliance with IEC 60068-3-5 and IEC 60068-3-6<br />

2 Non continuous tests; +2/+94°C for continuous tests<br />

3 Measured at 1 metre from <strong>the</strong> front in free environment<br />

Performances related to standard supply, without accessories and options.<br />

___________________________________________________________________________________________________________________ page 7


<strong>Sunrise</strong> – <strong>the</strong> <strong>beginning</strong> <strong>of</strong> a <strong>brand</strong> <strong>new</strong> <strong>day</strong><br />

__________________________________________________________________________________________________________<br />

“SPEEDY” SERIES - The right chambers for <strong>the</strong> real Stress Screening<br />

The “speedy” is a chamber series that can perform stress<br />

screening tests according to <strong>the</strong> main Standards in this<br />

field.<br />

So those chambers can maintain what <strong>the</strong>y promise<br />

without any trouble, thanks to powerful cooling units and<br />

ventilation systems that allow to stress <strong>the</strong> specimen as<br />

per <strong>the</strong> values measured on air. This is a “must” to ensure<br />

a correct stress screening and to avoid big difference<br />

between temperatures measured on air and on <strong>the</strong><br />

specimen, that makes useless <strong>the</strong> test.<br />

ESS has been developed to help manufacturers detecting<br />

product defects and production flaws. Screening can force<br />

infancy board and component failures that would<br />

o<strong>the</strong>rwise occur after final assembly and product delivery,<br />

and potentially during <strong>the</strong> warranty period.<br />

Two versions are available, according to <strong>the</strong> Temperature<br />

Rate <strong>of</strong> Change (10°C/min and 15°C/min)<br />

GOALS:<br />

➢・To remove all type <strong>of</strong> defects<br />

➢・Not doing damage to o<strong>the</strong>rwise good material<br />

➢・Corrective actions on design and production<br />

➢・Increase reliability<br />

ESS Improves<br />

➢・Product quality<br />

➢・Product reliability<br />

➢・Production throughput<br />

➢・Pr<strong>of</strong>it margins<br />

➢・Customer satisfaction<br />

costs<br />

ESS Reduces<br />

➢・Fields defect<br />

➢・Warranty costs<br />

➢・Time to market<br />

➢・Infancy failures on<br />

field<br />

➢・Manufacturing<br />

MODEL * SU250 TC ESS SU500 TC ESS SU1000 TC ESS SU1400 TC ESS<br />

FEATURES<br />

Useful capacity (litres) 252 441 1030 1326<br />

Int. dim. mm (WxDxH) 600x600x700 850x582x892 1000x1010x1020 1000x1300x1020<br />

Ext. dim. mm (WxDxH) 850x1974x1592 1100x1955x2030 1250x2409x2147 1250x2784x2147<br />

Temperature range -70°C/+180°C -70°C/+180°C -70°C/+180°C -70°C/+180°C<br />

Precision over time (T) ±0.5…±1.0°C ±0.5…±1.0°C ±0.5…±1.0°C ±0.5…±1.0°C<br />

Heating Temperature Rate 1 10°C or 15°C/min 10°C or 15°C/min 10°C or 15°C/min 10°C or 15°C/min<br />

Cooling Temperature Rate 1 10°C or 15°C/min 10°C or 15°C/min 10°C or 15°C/min 10°C or 15°C/min<br />

Maximum Internal Dissipation (W) at T= -55°C 10°C/min = 4000 10°C/min = 5500 10°C/min = 7000 10°C/min = 7500<br />

15°C/min = 4500 15°C/min = 6000 15°C/min = 7500 15°C/min = 8000<br />

Noise Level dBA 2 70 75 80 80<br />

* All models are available also with humidity control<br />

1 In compliance with IEC 60068-3-5 and IEC 60068-3-6<br />

2 Measured at 1 metre from <strong>the</strong> front in free environment<br />

Performances related to standard supply, without accessories and options.<br />

___________________________________________________________________________________________________________________ page 8


<strong>Sunrise</strong> – <strong>the</strong> <strong>beginning</strong> <strong>of</strong> a <strong>brand</strong> <strong>new</strong> <strong>day</strong><br />

__________________________________________________________________________________________________________<br />

DEWPPY SERIES<br />

The Dewppy chamber differs from <strong>the</strong> o<strong>the</strong>r series by its humidification system. The control <strong>of</strong> <strong>the</strong> relative humidity is<br />

done by means <strong>of</strong> a bath <strong>the</strong>rmoregulated at dew point.<br />

These chambers mainly satisfy <strong>the</strong> needs for severe climatic tests where a high stability and precision <strong>of</strong> Relative<br />

Humidity and Temperature parameters are required.<br />

MODEL SU300 DEWPPY (C) SU500 DEWPPY (C) SU1000 DEWPPY (C)<br />

FEATURES<br />

Useful capacity (litres) 281 504 1052<br />

Int. dim. mm (WxDxH) 600x676x700 850x665x895 1000x1034x1020<br />

Ext. dim. mm (WxDxH) 850x1725x1566 1100x1705x1961 1250x2160x2086<br />

Temperature range –40°C/+180°C –40°C/+180°C –40°C/+180°C<br />

C version –75°C/+180°C –75°C/+180°C –75°C/+180°C<br />

Precision over time (T)<br />

for <strong>the</strong>rmostatic tests: ±0,25...±0,3°C ±0,25...±0,3°C ±0,25...±0,3°C<br />

for climatic tests: ±0,1...±0,2°C ±0,1...±0,2°C ±0,1...±0,2°C<br />

Heating Temperature Rate 1 (–40/+180°C) 4,5°C/min 4,5°C/min 4°C/min<br />

C version (–70/+180°C) 4,5°C/min 4,5°C/min 4°C/min<br />

Cooling Temperature Rate 1 (+180/–40°C) 3°C/min 4°C/min 4°C/min<br />

C version (+180/–70°C) 2°C/min 4°C/min 3°C/min<br />

R.H. range (τ = +4/+94°C) 10%…98% 10%…98% 10%…98%<br />

R.H. precision ±1%...±2% ±1%...±2% ±1%...±2%<br />

Int. dissipation T= –25°C 400W 1000W 1300W<br />

C version: T= –55°C 500W 1200W 1500W<br />

Noise dBA 2 59 64 65<br />

C version 63 66 68<br />

1 In compliance with IEC 60068-3-5 and IEC 60068-3-6<br />

2 Measured at 1 metre from <strong>the</strong> front in free environment<br />

Performances related to standard supply, without accessories and options.<br />

V SERIES | BIO-CHAMBERS<br />

Control system<br />

By two (2) electronic controllers with digital display (one for<br />

temperature complete with a PT 100 probe and one for<br />

humidity complete with capacitive probe) based on P.I.D.<br />

regulation system. Alarm for: open door, maximum pressure<br />

and maximum internal temperature.<br />

If requested, <strong>the</strong> regulation can be carried out by <strong>the</strong> PLC<br />

electronic programmer for humidity and temperature cycle<br />

operation<br />

Purpose<br />

<strong>Sunrise</strong>700 V and 1500 V are primarily used for stability<br />

tests in <strong>the</strong> chemical-pharmaceutical sector. The small<br />

external dimensions, easy use, reduced consumption <strong>of</strong><br />

energy and high reliability <strong>of</strong> <strong>the</strong> chambers are <strong>the</strong> main<br />

characteristics for use in research laboratories. All <strong>the</strong><br />

models proposed comply with ICH regulations.<br />

Chamber configuration<br />

Back doors are provided with external lock and key.<br />

Internal double doors with toughened glass. Internal<br />

chamber in stainless steel AISI 304 with internal round<br />

<strong>of</strong>f corners for easy cleaning and disinfection. Height<br />

adjustable plasticized steel internal shelves.<br />

Air treatment system<br />

Copper tube battery evaporator, smooth tube for<br />

excellent dehumidification, low pressure steam<br />

generator (demineralised water at Customer care),<br />

electrical heaters and centrifugal blower for air<br />

circulation.<br />

Refrigeration unit<br />

Completely sealed, with silent hermetic compressors<br />

using ecologically friendly refrigerants. The air<br />

condenser is installed in <strong>the</strong> machine compartment.<br />

MODEL SU700 V SU1500 V<br />

FEATURES<br />

Useful Capacity (l) 600 1400<br />

Internal Useful Dimension (WxDxH) mm 590X675X1500 1330X675X1500<br />

External Dimension (WxDxH) mm 740X815X2030 1480X815X1998<br />

Temperature Range (°C) -20 … +70 * -10 … +60*<br />

Precision over ti me (T) ±0.5°C ±0.5°C<br />

Heating Temperature Rate 1 1°C/min 0.5°C/min<br />

Cooling Temperature Rate 1 1°C/min 0.5°C/min<br />

R.H. Range [10°C


<strong>Sunrise</strong> – <strong>the</strong> <strong>beginning</strong> <strong>of</strong> a <strong>brand</strong> <strong>new</strong> <strong>day</strong><br />

__________________________________________________________________________________________________________<br />

___________________________________________________________________________________________________________________ page 10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!