Two (2) 100-watt Cast SA4319 speakers shall be installed through the front bumper of the vehicle. The<br />

speakers shall not protrude beyond the face of the bumper or bumper guards. The system as installed shall<br />

meet the minimum requirements of Federal Specification KKK-A-1822F.<br />

Does your bid comply?<br />

Yes __X__ No_____<br />

Assist Handle and Grab Rails<br />

A 24” assist handle will be located on inside curb side door on the outside of the right front cabinets and<br />

another 24” assist handle will be located at the rear on the inside of the module on the street side. These shall<br />

stainless steel, 1-1/4” diameter, and shall be firmly anchored in order to safely support persons using them to<br />

aid in entry and egress from the vehicle.<br />

Does your bid comply?<br />

Yes __X__ No_____<br />

One (1) 72” long x 1.25” diameter overhead assist rail shall be mounted on the ceiling above the primary<br />

patient, contour rolled at each end with no protruding sharp edges. The grab rail shall be installed and<br />

perform in accordance with AMD Standard 008. They shall be mounted into roof structure, and shall be<br />

stainless steel.<br />

Does your bid comply?<br />

Yes __X__ No_____<br />

ADDITIONAL SYSTEMS, EQUIPMENT, ACCESSORIES & SUPPLIES<br />

Standard Mandatory Miscellaneous Equipment<br />

Unless otherwise precluded elsewhere in this specification, the ambulance shall be equipped with but not<br />

limited to the following:<br />