Cabinet Layout<br />

See drawings accompanying this specification for required cabinetry and layout.<br />

Does your bid comply?<br />

Yes __X__ No_____<br />

Technician Seat<br />

The technician seat shall be positioned so that the technician, when seated, is located at the head of the<br />

primary cot facing the patient. There shall be a minimum of 25 inches and a maximum of 30 inches clearance<br />

at floor level between the head of the cot and the technician seat backrest. The seat is to be an automotive<br />

style, high-backed, heavy-duty vinyl chair with built in child seat, with fore and aft track adjustment, mounted<br />

on an aluminum storage box.<br />

Restraints meeting all FMVSS and KKK1822 specifications must be supplied.<br />

Does your bid comply?<br />

Yes ___X_ No_____<br />

Ceiling Headliner<br />

The ceiling headliner shall be foam padded upholstery material. The headliner shall have an access panel full<br />

length down the center from front to rear in order to facilitate repairs and maintenance of the main electrical<br />

wiring loom in the patient compartment.<br />

Does your bid comply?<br />

Yes __X__ No_____<br />

Cot Mounting Device<br />

A two-position Stryker movable cot retention system including “antler” and lock down bar shall be provided<br />

and installed, and will be adjusted and lubricated per manufacturer’s specifications by qualified personnel<br />

prior to delivery.<br />