Patient Compartment Carbon Monoxide Level<br />

The ambulance modular body shall be constructed in such a manner as to provide a safe environment for<br />

patients and crew as pertains to the presence of carbon monoxide (CO). A CO level of not more than ten (10)<br />

PPM shall be attained in accordance with AMD Standard 007.<br />

Does your bid comply?<br />

Yes __X__ No_____<br />

PATIENT COMPARTMENT<br />

Interior Surfaces<br />

The interior of the patient compartment shall be free of all sharp projections. Exposed edges and corners shall<br />

be broken with a radius or chamfer. All hinges or supports for equipment and devices shall be mounted as<br />

flush as possible with the surrounding surface when not in use. Padding shall be placed at all head area<br />

obstructions, which may prove dangerous to persons moving about in the patient compartment.<br />

Other exposed edges shall be broken with a least .125" radius or chamfer and at least a .50” radius aluminum<br />

extrusion on exposed corners.<br />

Does your bid comply?<br />

Yes __X__ No_____<br />

The finish of the entire patient compartment, including storage cabinets and equipment, shall be impervious<br />

to soap and water, disinfectants, mildew and shall be fire resistant as per FMVSS 302. The color of the interior<br />