Above the door there shall be a cabinet with storage for (3) glove boxes. There shall be openings in the<br />

cabinet door for dispensing of the gloves.<br />

Does your bid comply?<br />

Yes __X__ No_____<br />

Front Wall Walk-Through<br />

There shall be a walk through between the driver's and patient compartment. For the Type I the cab roof must<br />

be raised by the installation of a “bubble” fabricated for that purpose in order to provide increased headroom<br />

for egress.<br />

Does your bid comply?<br />

Yes __X__ No_____<br />

Insulation<br />

The entire ambulance body, sides, ends, and roof of the patient's compartment shall be insulated to meet or<br />

enhance the environmental criteria specified in Federal Specifications KKK-A-1822. The walls shall be insulated<br />

with 1.875” block poly Styrofoam. There shall be 3.5" inch, R11 fiberglass batting in the roof and along the<br />

exterior roof and corner extrusions. There shall be 3/8” foil backed foam insulation installed around the<br />

perimeter of the A/C – Heater evaporator units, walls and ceiling in addition. The 3/8” foil backed material<br />

shall be utilized in areas where the harnesses and block foam are in conflict. There shall be no voids in the wall<br />

insulation process. There shall be an acoustical matting installed above the wheel well liners, in the floor, and<br />

on the exterior compartments on the sides towards the module interior. This material shall also be installed on<br />

the back sides of the interior aluminum cabinetry. The sub-floor shall be insulated with spray in foam<br />

insulation for acoustical and environmental insulation. The doors shall be insulated with at least 1.875" of<br />

plank foam. This insulation shall not interfere with the workings of the door latching hardware.<br />

Does your bid comply?<br />

Yes __X__ No_____<br />

Patient Compartment Sound Level<br />

Sound levels within the patient compartment shall not exceed eighty (80) decibels in accordance with AMD<br />

Standard 006.<br />

Does your bid comply?<br />

Yes __X__ No_____<br />