wired to the engine block heater through a switch to be located in the electrical compartment. It shall also be<br />

wired to a 115 Volt Broan 1000 watt minimum, with internal thermostat, which shall be installed in the face of<br />

the squad bench at the head end. There is to be a light and buzzer alarm system which shall sound and light up<br />

when the shoreline is connected and the ignition turned on.<br />

This wiring shall comply with AMD Standard 009.<br />

Does your bid comply?<br />

Yes __X__ No_____<br />

Rear Control Switch Panel<br />

All switches and controls for the patient compartment including those for the heat and air units shall be<br />

located on a service panel in the action area. These switches shall be of the same design and construction as<br />

found on the front control switch panel. The panel shall be connected to the electronic control module by a<br />

computer cable. The panel shall include but not be limited to, controls for patient compartment dome lights,<br />

fluorescent lights, action area light, vacuum system, electric oxygen solenoid, three-light silent intercom, and<br />

three spare switches for future use. The switch for the vacuum system must be red in color as opposed to all<br />

the rest being standard black. These switches shall not be activated unless the "MASTER" switch on the front<br />

control switch panel is in the "ON" position. There shall also be a digital 12/24 hour clock with a timer<br />

function incorporated into the rear switch panel.<br />

Does your bid comply?<br />

Yes __X__ No_____<br />

Marking of Switches, Indicators and Control Devices<br />

All switches, indicators and control devices supplied by the ambulance manufacturer shall employ<br />

permanently engraved translucent labels. Backlighting shall be activated when the "MASTER" switch is on.<br />

Decals or other "stick on" type labels are NOT ACCEPTABLE.<br />

Does your bid comply?<br />

Yes __X__ No_____<br />

Door Open Warning Module<br />

All door open warning switches will be wired through individual circuits directly to a solid-state LED diagnostic<br />

board. There will be individual circuit connections with individual LED circuit indicators for identifying switch<br />

or circuit failures. This module will be located in the ECC. An audible alarm will be mounted in the front<br />

32<br />

Attachment number 1<br />

4-4<br />

Page 66