Ammeter<br />

The electrical system shall incorporate an LED (digital) ammeter, which is capable of indicating a current of 200<br />

amperes and shows the total amp draw of the conversion system on the dual batteries. The ammeter shall<br />

incorporate an external shunt, which does not exceed 50 mill volts at maximum current. The ammeter and<br />

shunt shall have a combined accuracy of approximately 10 percent of the full-scale reading. The ammeter shall<br />

be located in the driver's control console. The shunt shall be protected against physical damage, weather and<br />

road spray and shall be mounted in an easily accessible location that shall minimize the length of the power<br />

cables.<br />

Does your bid comply?<br />

Yes __X__ No_____<br />

Voltmeter<br />

The vehicle shall be equipped with an LED (digital) voltmeter to monitor total system voltage. The voltmeter<br />

connection shall be direct to eliminate erroneous readings from connection voltage drops. The voltmeter shall<br />

have a minimum accuracy of +/- 5%. The voltmeter shall be mounted in the front control switch panel.<br />

Does your bid comply?<br />

Yes __X__ No_____<br />

Module Disconnect Switch<br />

This switch shall be located on the front control switch panel and shall disconnect all patient compartment<br />

conversion circuits. The switch shall be connected to the electronic control module through a computer cable.<br />

The switch label shall be back lighted, permanently identifying it as to function and have a green LED indicator<br />

to show that function is activated. This switch shall be different than other switches on the console, with a<br />

paddle handle and be red in color.<br />

Does your bid comply?<br />

Yes __X__ No_____<br />

Emergency Lights Master Switch<br />

The emergency lights "master" switch shall be a paddle type switch having a translucent label with a RED "on"<br />

indicator. The remainder of the function switches shall be low voltage switches. The switch shall be connected<br />

to the electronic control module through a computer cable. All switch labels shall be back lighted,<br />

permanently identifying it as to function and have an LED indicator to show what function is activated.<br />

26<br />

Attachment number 1<br />

4-4<br />

Page 60