19.11.2014 Views

Circuit-breakers NZM1, 2, 3, 4 up to 2000 A - Moeller Electric Parts

Circuit-breakers NZM1, 2, 3, 4 up to 2000 A - Moeller Electric Parts

Circuit-breakers NZM1, 2, 3, 4 up to 2000 A - Moeller Electric Parts

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

10/136<br />

Technical data<br />

Auxiliary contacts<br />

<strong>Circuit</strong>-<strong>breakers</strong>, switch-disconnec<strong>to</strong>rs<br />

M22-K…, XHI(V)<br />

<strong>Moeller</strong> HPL0211-2007/2008<br />

at AC = 50/60 Hz M22-K… NZM-XHIV NZM-XHI<br />

Auxiliary contacts<br />

Rated operational voltage<br />

AC U e V AC 500 500 500<br />

DC Ue V DC 220 220 220<br />

Conventional thermal current I th = I e A 4 4 4<br />

Rated operational current<br />

AC–15 115 V I e A 4 4 4<br />

http://catalog.moeller.net<br />

230 V I e A 4 4 4<br />

400 V I e A 2 2 2<br />

500 V I e A 1 1 1<br />

DC-13 24 V I e A 3 3 3<br />

42 V I e A 1.7 1.5 –<br />

60 V I e A 1.2 0.8 1.2<br />

110 V I e A 0.8 0.5 0.5<br />

220 V I e A 0.3 0.2 0.2<br />

Short-circuit protection<br />

max. fuse A gG/gL 10 10 10<br />

Max. miniature circuit-breaker A PKZM0-10/FAZ-B6 FAZ-B6 FAZ-B6<br />

Early-make time compared <strong>to</strong> the main contacts<br />

during switch on and off (switching times with<br />

manual operation)<br />

ms <strong>NZM1</strong>, PN1, N(S)1: approx. 20<br />

NZM2, PN2, N(S)2: approx. 20<br />

NZM3, PN3, N(S)3: approx. 20<br />

NZM4, N(S)4: approx. 90<br />

With NZM4/N(S)4 the HIV<br />

does not feature early break.<br />

Terminal capacities<br />

Solid or flexible conduc<strong>to</strong>r with ferrule mm 2 1 x (0.75 – 2.5)<br />

2 x (0.75 – 2.5)<br />

AWG 1 x (18 – 14)<br />

2 x (18 – 14)<br />

UL/CSA<br />

Rated operational current I e A 10 A … 600 V AC<br />

1 A … 250 V DC<br />

1 x (0.75 – 2.5)<br />

2 x (0.75 – 2.5)<br />

1 x (18 – 14)<br />

2 x (18 – 14)<br />

2.5 A – 240 V AC<br />

1 A – 250 V DC<br />

1 x (0.75 – 2.5)<br />

2 x (0.75 – 2.5)<br />

1 x (18 – 14)<br />

2 x (18 – 14)<br />

2.5 A – 240 V AC<br />

1 A – 250 V DC<br />

Heavy Pilot Duty<br />

A600/P300<br />

above 300 V AC same<br />

polarity<br />

C300/R300<br />

C300/R300<br />

For <strong>Moeller</strong> <strong>Electric</strong> Sales and S<strong>up</strong>port call KMparts.com (866) 595-9616