Circuit-breakers NZM1, 2, 3, 4 up to 2000 A - Moeller Electric Parts
Circuit-breakers NZM1, 2, 3, 4 up to 2000 A - Moeller Electric Parts
Circuit-breakers NZM1, 2, 3, 4 up to 2000 A - Moeller Electric Parts
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
System overview<br />
<strong>Circuit</strong>-<strong>breakers</strong>, switch-disconnec<strong>to</strong>rs<br />
10/3<br />
http://catalog.moeller.net<br />
Basic units<br />
<strong>Circuit</strong>-breaker 1<br />
Rated uninterr<strong>up</strong>ted current <strong>up</strong> <strong>to</strong> <strong>2000</strong> A<br />
Switching capacity 25, 36, 50, 100, 150 kA at<br />
415 V<br />
Adjustable releases for overload and shortcircuit<br />
Adjustable time selectivity<br />
Earth-fault protection<br />
Protection of systems, cables, mo<strong>to</strong>rs,<br />
genera<strong>to</strong>rs<br />
3 and 4 pole versions,IEC/EN 60947<br />
a page 10/6<br />
Switch-disconnec<strong>to</strong>r 1<br />
Rated uninterr<strong>up</strong>ted current <strong>up</strong> <strong>to</strong> 1600 A<br />
Remotely tripped switch-disconnec<strong>to</strong>r with<br />
undervoltage or shunt release<br />
3 and 4 pole versions,IEC/EN 60947<br />
a page 10/24<br />
<strong>Circuit</strong>-<strong>breakers</strong> for North America 1<br />
Rated uninterr<strong>up</strong>ted current <strong>up</strong> <strong>to</strong> 1200 A<br />
Switching capacity 25, 35, 65, 100 kA at 480 V<br />
Adjustable releases for overload and shortcircuit<br />
Adjustable time selectivity<br />
Earth-fault protection<br />
Protection of systems, cables, mo<strong>to</strong>rs,<br />
genera<strong>to</strong>rs<br />
3 pole version, UL489/CSA22.2 No.5.1, IEC/<br />
EN 60947<br />
a page 10/28<br />
Molded case switches for North America 1<br />
Rated uninterr<strong>up</strong>ted current <strong>up</strong> <strong>to</strong> 1200 A<br />
Remotely tripped with undervoltage or shunt<br />
release<br />
3 pole version, UL489/CSA22.2 No.5.1<br />
a page 10/42<br />
<strong>Moeller</strong> HPL0211-2007/2008<br />
Add-on functions<br />
Standard auxiliary contact (HIN) 13<br />
Switching with the main contacts. Used for<br />
indication and interlock functions.<br />
Trip-indicating auxiliary contact (HIA) 13<br />
General trip indication '+', when tripped by<br />
voltage release, overload release or shortcircuit<br />
release<br />
Early-make auxiliary contacts 28<br />
For interlocking and load shedding circuits, as<br />
well as for early make of the undervoltage<br />
release in main switch/Emergency-s<strong>to</strong>p<br />
applications<br />
a page 10/70<br />
Voltage release 28<br />
Undervoltage release<br />
• Non-delayed<br />
•OFF-delayed<br />
Shunt release<br />
a page 10/72<br />
Delay unit for undervoltage release 29<br />
a page 10/77<br />
Rear drive 14<br />
a page 10/90<br />
Door co<strong>up</strong>ling rotary handle 16,<br />
18<br />
•Lockable<br />
• With door interlock<br />
a page 10/82<br />
Main switch rotary handle for side panel 15<br />
mounting<br />
a page 10/88<br />
Extension shaft 17<br />
Can be cut <strong>to</strong> required length.<br />
a page 10/82<br />
Rotary handle 19<br />
Lockable<br />
a page 10/86<br />
Remote opera<strong>to</strong>r 22<br />
For remote switching of circuit-<strong>breakers</strong> and<br />
switch-disconnec<strong>to</strong>rs<br />
a page 10/96<br />
Toggle lever interlock device 23<br />
a page 10/92<br />
Side opera<strong>to</strong>r handle 24<br />
a page 10/91<br />
Data Management Interface (DMI 25<br />
module)<br />
Access <strong>to</strong> diagnostics and operational data<br />
Recording of current values<br />
Mo<strong>to</strong>r starter function<br />
Parameterization and control of the circuit<strong>breakers</strong><br />
with electronic releases<br />
a page 10/98<br />
EASY-LINK-DS data plug 26<br />
a page 4/45<br />
PROFIBUS-DP interface 27<br />
a page 10/98<br />
NZM<br />
Mounting accessories<br />
Control circuit terminal 8<br />
For two terminals at <strong>to</strong>p or bot<strong>to</strong>m<br />
<strong>NZM1</strong> a page 10/49<br />
NZM2 a page 10/53<br />
NZM3 a page 10/57<br />
NZM4 a page 10/57<br />
Tunnel terminals for Al and Cu cable 6<br />
Standard with control circuit terminal<br />
<strong>NZM1</strong> a page 10/47<br />
NZM2 a page 10/51<br />
NZM3 a page 10/57<br />
NZM4 a page 10/63<br />
Box terminals 7<br />
Standard version of frame size 1 assembled<br />
within the circuit-breaker enclosure<br />
<strong>NZM1</strong> a page 10/47<br />
NZM2 a page 10/51<br />
NZM3 a page 10/55<br />
Terminal cover 4<br />
Protection against direct contact wherecable<br />
lugs, busbars or tunnel terminals are used<br />
<strong>NZM1</strong> a page 10/49<br />
NZM2 a page 10/53<br />
NZM3 a page 10/58<br />
NZM4 a page 10/67<br />
Terminal cover, knockout 3<br />
<strong>NZM1</strong> a page 10/49<br />
NZM2 a page 10/53<br />
NZM3 a page 10/58<br />
NZM4 a page 10/67<br />
Clip plate 10<br />
<strong>NZM1</strong>-XC35 a for 35 mm <strong>to</strong>p-hat rail<br />
NZM2-XC75 a for 75 mm <strong>to</strong>p-hat rail<br />
a page 10/92<br />
Rear connection 11<br />
<strong>NZM1</strong> a page 10/47<br />
NZM2 a page 10/51<br />
NZM3 a page 10/57<br />
NZM4 a page 10/63<br />
Plug-in and withdrawable unit 9<br />
a page 10/68<br />
Insulating surround 21<br />
For use with <strong>to</strong>ggle lever, rotary drive and<br />
remote opera<strong>to</strong>r protruding from the<br />
enclosure<br />
a page 10/92<br />
External warning plate/designation label 20<br />
a page 10/90<br />
Spacer 12<br />
a page 10/92<br />
IP2X protection against contact with a finger 2<br />
For box terminals<br />
<strong>NZM1</strong> a page 10/49<br />
NZM2 a page 10/53<br />
NZM3 a page 10/58<br />
IP2X protection against contact with a finger 5<br />
For barrier<br />
<strong>NZM1</strong> a page 10/49<br />
NZM2 a page 10/53<br />
NZM3 a page 10/58<br />
<strong>Circuit</strong>-<strong>breakers</strong>, switch-disconnec<strong>to</strong>rs<br />
For <strong>Moeller</strong> <strong>Electric</strong> Sales and S<strong>up</strong>port call KMparts.com (866) 595-9616