Command 102 PERSIST Name PPERSIST RESET RESPTIME RESTART RETRY SENDPAC SLOTTIME TRACE TRIES TXDELAY Short Default Parameter PE 128 0 ~ 255 PP ON ON/ OFF Description Specifies a parameter to calculate probability for the PERSIST/SLOTTIME method. Causes the TNC to use the PERSIST/SLOTTIME method when ON, or the DWAIT method when OFF. R ESET — — Restores the default status for all the commands. RES 5 0 ~ 250 Specifies the acknowledgment packet transmission delay. The unit of the parameter is 100 milliseconds. R ESTAR T — — Causes the TNC to function as if it is switched OFF then ON. RE 10 0 ~ 15 SE Specifies the number of transmission retries. If packets are not correctly accepted while in connection, a connect request is sent again after the specified number of retries. $ 0D 0 ~ $7F Specifies a character which forces a packet to be sent. SL 3 0 ~ 250 TRAC OFF UNPROTO U CQ XFLOW X ON ON/ OFF TRI 0 0 ~ 15 TX 50 0 ~ 120 Call1 (VIA call2, call3, ... call9) ON/ OFF Specifies the period of random number generation intervals for the PERSIST/SLOTTIME method. The unit of the parameter is 10 milliseconds. When ON, causes the TNC to display all received packets in their entirety. Specifies the number of transmission retries programmed in the retry counter. Specifies the time delay between PTT ON and start of transmission. The unit of the parameter is 10 milliseconds. Specifies call signs to send a packet in Unprotocol mode. Call1 is the call sign of the destination. Call2 to call9 are call signs of stations to be digipeated through. Causes the TNC to perform software flow control when ON, or hardware flow control when OFF.

Accessories Optional ........................................ 94 Supplied .......................................... 1 Advanced Intercept Point (AIP) ......... 51 APRS Programming .......................... 66~75 Receiving ...................................... 63 Transmitting .................................. 74 APRS Message Entering ........................................ 79 Receiving ...................................... 77 Transmitting .................................. 80 Automatic Power Off (APO) .............. 49 Automatic Simplex Check (ASC) ...... 24 Band, Selecting ............................. 7, 12 Battery Saver ..................................... 49 Beep ON/OFF .................................... 47 Call Channel Contents, Changing ...................... 30 Recalling ....................................... 30 Channel Display ................................ 31 CTCSS Freq. ID ......................................... 40 Frequency, Selecting ..................... 39 Using ............................................ 40 Data Band .......................................... 55 Display Contrast, Adjusting ............... 48 INDEX DTMF Making Calls ................................. 41 Storing Numbers ........................... 42 Transmitting Stored Numbers ........ 43 TX Hold ......................................... 41 Frequency, Selecting ..................... 7, 45 Frequency Step Size ......................... 46 Full Duplex ......................................... 55 Lamp Function ................................... 48 Lock, Transceiver .............................. 50 Memory Channels Clearing ........................................ 28 Initializing ...................................... 32 Locking Out ................................... 36 Naming ......................................... 29 Recalling ....................................... 28 Storing, Odd-split .......................... 27 Storing, Simplex ............................ 27 Transfer to VFO ............................ 31 Menu .................................................. 16 Microphone Control ........................... 44 Offset Automatic Repeater ...................... 23 Offset Direction ............................. 21 Offset Frequency ........................... 21 Packet Operation ............................... 52 Power-ON Message .......................... 50 Programmable VFO ........................... 46 Repeater Access ............................... 20 Reset Full ................................................ 32 Partial (VFO) ................................. 32 Reverse Function .............................. 24 Scan Call/Memory .................................. 38 Call/VFO ....................................... 38 Memory ......................................... 35 MHz .............................................. 36 Program ........................................ 37 Resume Method ............................ 34 VFO .............................................. 35 Sky Command 2 (TH-D7A only) ...... 83 Slow-Scan Television (SSTV) ............ 57 Specifications..................................... 97 Squelch, Adjusting ............................... 8 TNC .................................................... 53 Tone Activating ...................................... 22 Freq. ID ......................................... 25 Frequency, Selecting ..................... 22 Tone Alert ........................................... 47 Transmit Power, Selecting ................... 9 Troubleshooting ................................. 90 TX Deviation (TH-D7E only) .............. 51 TX Inhibit ............................................ 51 Volume Balance, Adjusting ................ 48 Wireless Remote Control (TH-D7A only) .................................... 81 53

Command<br />

102<br />

PERSIST<br />

Name<br />

PPERSIST<br />

RESET<br />

RESPTIME<br />

RESTART<br />

RETRY<br />

SENDPAC<br />

SLOTTIME<br />

TRACE<br />

TRIES<br />

TXDELAY<br />

Short<br />

Default<br />

Parameter<br />

PE<br />

128<br />

0 ~ 255<br />

PP<br />

ON<br />

ON/ OFF<br />

Description<br />

Specifies a parameter to calculate probability for the<br />

PERSIST/SLOTTIME method.<br />

Causes the TNC to use the PERSIST/SLOTTIME method<br />

when ON, or the DWAIT method when OFF.<br />

R ESET<br />

— — Restores the default status for all the commands.<br />

RES<br />

5 0 ~ 250<br />

Specifies the acknowledgment packet transmission delay.<br />

The unit of the parameter is 100 milliseconds.<br />

R ESTAR T — — Causes the TNC to function as if it is switched OFF then ON.<br />

RE<br />

10<br />

0 ~ 15<br />

SE<br />

Specifies the number of transmission retries. If packets are<br />

not correctly accepted while in connection, a connect request<br />

is sent again after the specified number of retries.<br />

$ 0D<br />

0 ~ $7F<br />

Specifies a character which forces a packet to be sent.<br />

SL<br />

3 0 ~ 250<br />

TRAC<br />

OFF<br />

UNPROTO<br />

U CQ<br />

XFLOW<br />

X ON<br />

ON/ OFF<br />

TRI<br />

0 0 ~ 15<br />

TX<br />

50<br />

0 ~ 120<br />

Call1 (VIA<br />

call2, call3, ...<br />

call9)<br />

ON/ OFF<br />

Specifies the period of random number generation intervals<br />

for the PERSIST/SLOTTIME method. The unit of the<br />

parameter is 10 milliseconds.<br />

When ON, causes the TNC to display all received packets in<br />

their entirety.<br />

Specifies the number of transmission retries programmed in<br />

the retry counter.<br />

Specifies the time delay between PTT ON and start of<br />

transmission. The unit of the parameter is 10 milliseconds.<br />

Specifies call signs to send a packet in Unprotocol mode.<br />

Call1 is the call sign of the destination. Call2 to call9 are call<br />

signs of stations to be digipeated through.<br />

Causes the TNC to perform software flow control when ON, or<br />

hardware flow control when OFF.