19.11.2014 Views

PDF-Download - Microsens

PDF-Download - Microsens

PDF-Download - Microsens

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TDM<br />

Metropolitan Networks_10G Platform Category_TDM Technology_10G<br />

MICROSENS<br />

10G 8x Gigabit TDM<br />

Up to<br />

8 GBE switches<br />

Protection<br />

Building 2<br />

TDM<br />

8x GBE or FC<br />

TDM<br />

Main Link<br />

8x GBE TDM Module<br />

Up to<br />

8 GBE switches<br />

Building 1<br />

Benefits<br />

Description<br />

TDM aggregation up to 8x Gigabit<br />

Ethernet or 1G Fibre Channel<br />

Optional 1 +1 Line Protection<br />

Improved transmission performance<br />

by FEC<br />

Reducing the wavelengths in DWDM<br />

networks<br />

Increase transmission capacity of<br />

existing WDM network<br />

10G transport modules are ideally<br />

suited for optical metropolitan, regional<br />

and long haul networks<br />

Increase in bandwidth capacity at<br />

low cost<br />

The 8 port Gigabit TDM aggregates via time-division multiplexing (TDM) up to<br />

eight channels into a 10G Gigabit data stream and supports both Gigabit Ethernet<br />

and 1G Fibre Channel. Thus the transmission capacity of a 10G system can be<br />

significantly increased and maximized.<br />

The transmission on the line side can be achieved with standard XFP modules,<br />

or even with integrated DWDM Fixed Fiber Interfaces (FFI). For redundant or<br />

ring applications, the line interface can also be redundant. With the optional<br />

FEC-function (Forward Error Correction) great distances of 120 km and more<br />

can be achieved.<br />

For the exchange of network management information, the module has an<br />

integrated 10 Mbps data channel (in-line remote management), which will be<br />

transferred without restriction of the eight 1 Gigabit channels and is used for<br />

the coupling of the management modules via Ethernet. In addition, this Ethernet<br />

channel may be used for service purposes.<br />

Description<br />

8x GBE/GFC on 10G, port 1..8: SFP-slot, line port: 1x XFP-slot<br />

8x GBE/GFC on 10G, port 1..8: SFP-slot, line port: FFI B&W, x - FFI-option<br />

8x GBE/GFC on 10G, port 1..8: SFP-slot, line port: FFI DWDM, x - FFI-option*<br />

Art.-No.<br />

MS430620M<br />

MS430624M-x<br />

MS430624M-x-nn<br />

Metropolitan networks<br />

8x h GBE/GFC on 10G with Line Protection, port 1..8: SFP-slot,<br />

MS430624MP-xy-<br />

System Catalog 1610<br />

10G GBE TDM with Line Protection<br />

line port 1/2: 2x FFI-DWDM, x/y - FFI-option*<br />

8x GBE/GFC on 10G with FEC, port 1..8: SFP-slot, line port: FFI B&W , x - FFI-option<br />

8x GBE/GFC on 10G with FEC, port 1..8: SFP-slot, line port: FFI, x - FFI-option*<br />

8x GBE/GFC on 10G with FEC, port 1..8: SFP-slot, line port: tuneable FFI, x - FFI-option<br />

nnmm<br />

MS430627M-x<br />

MS430627M-x-nn<br />

MS430627MT-x<br />

*nn – DWDM channel number.<br />

www.microsens.com<br />

153

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!