2010.7<br />
Compliant<br />
www.cosel.co.jp/en<br />
Unit type AC-DC Switching Power Supply<br />
<strong>PMA</strong> <strong>series</strong><br />
For medical application use (Medical safety certification "EN60601/UL60601")<br />
Unit type AC-DC converter<br />
5 years warranty
Unit type<br />
Medical<br />
electric<br />
equipment<br />
Power<br />
Factor<br />
Correction<br />
World wide<br />
Safety<br />
Approvals<br />
EMI<br />
Inrush<br />
current<br />
limiting<br />
OCP OVP Remote<br />
ON/OFF<br />
<strong>PMA</strong>-<strong>series</strong><br />
Feature<br />
For medical electric equipment<br />
Internal dual fuses<br />
Harmonic attenuator (Complies with IEC61000-3-2)<br />
Universal input (AC85 - 264V)<br />
Efficiency increased with synchronous rectification<br />
technology (<strong>PMA</strong>60F, <strong>PMA</strong>100F)<br />
Variety of option<br />
Safety agency approvals<br />
UL60601-1, C-UL (CSA-C22.2 No.601.1), EN60601-1<br />
CE marking<br />
Medical Device Directive<br />
EMC Compliance : EN61204-3, EN61000-6-2<br />
EN61000-4-2<br />
EN61000-4-3<br />
EN61000-4-4<br />
EN61000-4-5 (Common mode Level4, Differential mode Level2)<br />
EN61000-4-6<br />
EN61000-4-8<br />
EN61000-4-11<br />
EMI<br />
FCC-B, CISPR22-B, EN55011-B, EN55022-B, VCCI-B<br />
5-year warranty (refer to Instruction Manual)
<strong>PMA</strong> <strong>series</strong> 15-100W<br />
For medical application use Unit type AC-DC converter<br />
(Medical safety certification "EN60601/UL60601")<br />
¡Medical safety certifications<br />
Medical safety certification "EN60601/UL60601" (*1).<br />
With compatibility to various standards of major countries, investigation time and cost for<br />
safety standard accreditation can be reduced.<br />
*1: EN60601-1, UL60601-1, C-UL pending<br />
¡Downsized<br />
Fuse is built-in both L and N phases. And enforced insulation. Therefore, additional fuse<br />
and insulation transformer are unnecessary, and thus downsizing the system is achieved.<br />
¿Conventionally,<br />
Power source without medical standard certifications<br />
L<br />
N<br />
Switching control<br />
Rectification, smooth<br />
System<br />
FG<br />
Externally<br />
· Fuse or breaker is necessary to both L and N phases.<br />
· Insulation transformer is necessary.<br />
Thus<br />
System is bigger, heavier, and thus cost increase.<br />
¿With <strong>PMA</strong> <strong>series</strong>,<br />
Fuse (or breaker) and insulation<br />
transformer are externally unnecessary.<br />
<strong>PMA</strong> <strong>series</strong> (medical power supply)<br />
L<br />
N<br />
Switching control<br />
Rectification, smooth<br />
System<br />
FG<br />
<strong>PMA</strong> <strong>series</strong> has<br />
· Fuses are built-in at both L and N phases.<br />
· Medical standard(enforced insulation) certification.<br />
Thus<br />
Therefore, additional fuse (or breaker) and insulation transformer<br />
are externally unnecessary, and thus the system is downsized,<br />
light-weighted, and the cost can be reduced.<br />
3
New unit-type power<br />
supply is provided for<br />
medical application use.<br />
¡Environmental load reduced<br />
NEW<br />
RoHS compliant<br />
All models: harmonic attenuator (IEC61000-3-2)<br />
Power factor improvement circuit is built-in in 60/100W, and lowering input capacity is<br />
achieved.<br />
¡various options<br />
Respond various requests by options.<br />
T : Vertical terminal block<br />
T1 : Horizontal terminal block<br />
N : With case cover<br />
J1 : VH (J.S.T) connector<br />
R : With remote control function (<strong>PMA</strong>60/100F)<br />
Option<br />
T1<br />
Option<br />
T<br />
Normal<br />
Option<br />
N<br />
¡Product lineup<br />
<strong>PMA</strong>15F <strong>PMA</strong>30F <strong>PMA</strong>60F <strong>PMA</strong>100F<br />
Model name<br />
Input voltage<br />
Harmonic attenuator<br />
Output voltage<br />
/current<br />
Leak current(AC100V/240V)<br />
Operating temperature<br />
Input - Output<br />
Isolation<br />
Safety standard<br />
Conducted noise<br />
External dimension (cover excluded)<br />
Input/output interface<br />
3.3V<br />
5V<br />
12V<br />
15V<br />
24V<br />
48V<br />
Input - FG<br />
Output - FG<br />
AC 85-264V 50/60Hz<br />
IEC61000-3-2 Harmonic attenuator<br />
3A 6A 12A 20A<br />
3A 6A 12A 20A<br />
1.3A 2.5A 5A 8.5A<br />
1A 2A 4A<br />
-<br />
0.7A 1.3A 2.5A<br />
4.5A<br />
- - - 2.1A<br />
0.05mA / 0.1mA<br />
0.09mA / 0.18mA<br />
-10-70ª (Derating)<br />
AC4,000V 1 min. Cut-off current=10mA,DC500V 50MΩ min(Room temp., normal humidity)<br />
AC2,000V 1 min. Cut-off current=10mA,DC500V 50MΩ min(Room temp., normal humidity)<br />
AC 500V 1 min. Cut-off current=25mA,DC500V 50MΩ min(Room temp., normal humidity)<br />
UL60601-1, C-UL, EN60601-1 pending<br />
FCC-B, VCCI-B, CISPR22-B, EN55011-B, Complies with EN55022-B<br />
31(W)†78 (H) †103 (D) mm 31(W)†82 (H) †120 (D) mm 32(W)†82 (H) †135 (D) mm 34(W)†93 (H) †168 (D) mm<br />
Connector (Normal : Tyco Electronics AMP, J.S.T.selectable) / Terminal block (selectable)<br />