PULMONARY MEDICINE SERVICE NOVEMBER 29, 2011<br />

F2017<br />

Waste Receptacle,<br />

24 Gal<br />

1 VV Rectangular steel waste receptacle with step-on lid<br />

and 24 gallon capacity. The receptacle is used to<br />

collect and temporarily store small quantities <strong>of</strong> paper<br />

refuse.<br />

F3200 Clock, Battery, 12"<br />

Diameter<br />

1 VV Clock, 12" diameter. Round surface, easy to read<br />

numbers with sweep second hand. Wall mounted unit<br />

for use when impractical to install a fully synchronized<br />

clock system. Battery operated, (batteries not included).<br />

M0720<br />

M1801<br />

P3100<br />

Analyzer, <strong>Pulmonary</strong><br />

Function, w/<br />

Computer<br />

Computer, Microprocessing,<br />

w/Flat<br />

Panel Monitor<br />

Lavatory, Vitreous<br />

China, Slab Type<br />

Dispenser, Glove,<br />

Triple<br />

<strong>Pulmonary</strong> Function<br />

Analyzer,<br />

Portable w/Cart<br />

Scale, Patient<br />

Step-On<br />

1 VV <strong>Pulmonary</strong> function analyzer system. Unit includes<br />

whole body plethysmography, spirometer, computer,<br />

and gas analyzers. Computer based system for use<br />

in cardio-pulmonary areas. The system measures<br />

the ventilation, diffusion and distribution <strong>of</strong> gases in<br />

the lungs. It has automatic calibration and valves are<br />

pneumatically operated and controlled by the computer.<br />

Used to measure the performance <strong>of</strong> a patient's<br />

respiratory system; for out-patient or pre-surgical<br />

screening. Systems have specific high pressure air<br />

and oxygen and low pressure helium requirements.<br />

Refer to manufacturer's literature.<br />

1 VV Desk top microprocessing computer. The unit shall<br />

consist <strong>of</strong> a central processing mini tower, flat panel<br />

monitor, keyboard, mouse and speakers.<br />

1 CC Wall mounted, slab type, vitreous china, lavatory (approximate<br />

bowl size 7"x15"x10") with: faucet holes on<br />

4" centers; gooseneck spout; wrist blade handles; and<br />

grid strainer.<br />

1 VV Triple glove box holder constructed <strong>of</strong> formed stainless<br />

steel for horizontal or vertical mounting.<br />

1 VV Portable pulmonary function analyzer. It includes a<br />

spirometer computer and gas analyzers. The system<br />

provides automatic calculations <strong>of</strong> inspiratory or<br />

expiratory volumes and flows, and gas distribution<br />

measurements. Portable or cart-mountable unit that<br />

can be wheeled anywhere in the hospital. Used as<br />

a screening system to determine baseline ventilatory<br />

function along with types and degrees <strong>of</strong> impairments<br />

to a patient's respiratory system.<br />

1 VV Person weighing scale with 400 pound capacity.<br />

Weight reading in pounds and kilogram with height<br />

measuring rod and wheels.<br />

DESIGN STANDARDS<br />

SECTION 4 - PAGE 51