Contact Building and LAN System Customer Service olexmktmgr.building@nexans.com Alsecure® Premium FRP Ceramifiable® LSOH range of fire Rated multipair cable rated to WS51W, Single Core ES110. Copper conductor, 110 VAC /150 VDC, Ceramifiable® insulated, Description Alsecure® Premium with INFIT Cermifiable® Instrumentation & Data are a range of (HFFR) Halogen Free Flame Retardant multipair cable rated to WS51W under fire test standard AS/NZ 3013:2005. These new cables are the only Fire Rated multipair product available that do not require glass-mica tapes, thus reducing installation time and eliminating the need for respirators and special gloves.. Benefits • Easy to install • No Mica Tape • No Protective Equipment needed • Fire Resistant • Halogen Free • Non Toxic • No Heavy metals • No Corrosive Emissions • Low Smoke • Low Calorific Value • Flexible Standards National AS/NZS 3013 The Alsecure® Premium FRP cables are available in standard pair counts of 1, 2, 4, 6, 8, & 10, in conductor sizes 0.75mm2 and 1.5mm2. Application • Alarms • Pumps • Fans • Fire Services Systems • Instrumentation Cables Voltage 110 V AC / 150 V DC Continuous Operating Temperature 90°C Colours Insulation - Natural/Black Outer Sheath - RED Only Rated Voltage Uo/U (Um) 110 VAC /150 VDC Maximum operating temperature 90 °C Version Fire Rated Alsecure Data Generated 9/03/14 - http://www.olex.com.au Page 1 / 3 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.

Contact<br />

Building and LAN System Customer<br />

Service<br />

olexmktmgr.building@nexans.com<br />

Alsecure® <strong>Premium</strong> <strong>FRP</strong> Ceramifiable®<br />

LSOH range of fire Rated multipair cable rated to WS51W, Single Core ES110. Copper conductor, 110 VAC /150 VDC,<br />

Ceramifiable® insulated,<br />

Description<br />

Alsecure® <strong>Premium</strong> with INFIT Cermifiable® Instrumentation & Data are a<br />

range of (HFFR) Halogen Free Flame Retardant multipair cable rated to WS51W<br />

under fire test standard AS/NZ 3013:2005. These new cables are the only Fire<br />

Rated multipair product available that do not require glass-mica tapes, thus<br />

reducing installation time and eliminating the need for respirators and special<br />

gloves..<br />

Benefits<br />

• Easy to install<br />

• No Mica Tape<br />

• No Protective Equipment needed<br />

• Fire Resistant<br />

• Halogen Free<br />

• Non Toxic<br />

• No Heavy metals<br />

• No Corrosive Emissions<br />

• Low Smoke<br />

• Low Calorific Value<br />

• Flexible<br />

Standards<br />

National AS/NZS 3013<br />

The Alsecure® <strong>Premium</strong> <strong>FRP</strong> cables are available in standard pair counts of 1, 2,<br />

4, 6, 8, & 10, in conductor sizes 0.75mm2 and 1.5mm2.<br />

Application<br />

• Alarms<br />

• Pumps<br />

• Fans<br />

• Fire Services Systems<br />

• Instrumentation Cables<br />

Voltage<br />

110 V AC / 150 V DC<br />

Continuous Operating Temperature<br />

90°C<br />

Colours<br />

Insulation - Natural/Black<br />

Outer Sheath - RED Only<br />

Rated Voltage Uo/U (Um)<br />

110 VAC /150 VDC<br />

Maximum operating temperature<br />

90 °C<br />

Version Fire Rated Alsecure Data Generated 9/03/14 - http://www.olex.com.au Page 1 / 3<br />

All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of<br />

Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.


Contact<br />

Building and LAN System Customer<br />

Service<br />

olexmktmgr.building@nexans.com<br />

Alsecure® <strong>Premium</strong> <strong>FRP</strong> Ceramifiable®<br />

Characteristics<br />

Construction characteristics<br />

Outer sheath<br />

Overall screen<br />

Insulation<br />

Conductor material<br />

Type of conductor<br />

Electrical characteristics<br />

Rated Voltage Uo/U (Um)<br />

Usage characteristics<br />

HFS-90-TP<br />

Aluminium polyester laminate tape + Stranded tinned<br />

annealed copper drain wire<br />

Ceramifiable®<br />

Annealed copper<br />

Stranded<br />

110 VAC /150 VDC<br />

Maximum operating temperature 90 °C<br />

Rated Voltage Uo/U (Um)<br />

110 VAC /150 VDC<br />

Maximum operating temperature<br />

90 °C<br />

Version Fire Rated Alsecure Data Generated 9/03/14 - http://www.olex.com.au Page 2 / 3<br />

All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of<br />

Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.


Contact<br />

Building and LAN System Customer<br />

Service<br />

olexmktmgr.building@nexans.com<br />

Alsecure® <strong>Premium</strong> <strong>FRP</strong> Ceramifiable®<br />

Conductor 0.75 mm²<br />

nb pairs<br />

Nom. overall diam.<br />

[mm]<br />

Approx. weight<br />

[kg/100m]<br />

Min. bend. radius during instal.<br />

[mm]<br />

Max. pulling tension<br />

[kN]<br />

Nexans ref.<br />

1 7.8 6.6 115 0.06 PBKP03AA001<br />

2 12.2 13.0 185 0.12 PBKP03AA002<br />

4 13.5 20.5 200 0.24 PBKP03AA004<br />

6 16.3 29.3 240 0.36 PBKP03AA006<br />

8 18.6 38.2 280 0.48 PBKP03AA008<br />

10 20.4 46.2 310 0.6 PBKP03AA010<br />

12 22.3 55.0 340 0.72 PBKP03AA012<br />

16 25.5 71.7 380 0.96 PBKP03AA016<br />

20 28.3 88.5 430 1.2 PBKP03AA020<br />

24 30.9 105.2 460 1.4 PBKP03AA024<br />

Conductor 1.5 mm²<br />

nb pairs<br />

Nom. overall diam.<br />

[mm]<br />

Approx. weight<br />

[kg/100m]<br />

Min. bend. radius during instal.<br />

[mm]<br />

Max. pulling tension<br />

[kN]<br />

Nexans ref.<br />

1 8.4 8.0 125 0.12 PBK184AA001<br />

2 13.2 15.8 200 0.24 PBK184AA002<br />

4 14.7 25.6 220 0.48 PBK184AA004<br />

6 17.6 36.9 270 0.72 PBK184AA006<br />

8 20.2 48.2 300 0.96 PBK184AA008<br />

10 22.4 59.6 340 1.2 PBK184AA010<br />

12 24.5 71.0 370 1.4 PBK184AA012<br />

16 28.0 92.7 420 1.9 PBK184AA016<br />

20 31.1 114.5 470 2.4 PBK184AA020<br />

24 33.9 136.2 500 2.9 PBK184AA024<br />

Selling information<br />

Individual/Overall Screened & Triple are available upon request MOQ applies<br />

Rated Voltage Uo/U (Um)<br />

110 VAC /150 VDC<br />

Maximum operating temperature<br />

90 °C<br />

Version Fire Rated Alsecure Data Generated 9/03/14 - http://www.olex.com.au Page 3 / 3<br />

All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of<br />

Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!