COUNCIL MINUTES<br />
TUESDAY 20 DECEMBER 2011<br />
For the Southport Street Node, the West Leederville Planning and Urban Design Study outlines<br />
a number <strong>of</strong> proposed development controls. The development controls relevant to this<br />
proposal are:-<br />
Minimum 2 storeys, preferably 3 storeys, maximum 8 storeys;<br />
Maximum 3 storeys along street frontages, with any additional height to a maximum <strong>of</strong> 8<br />
storeys to be set back;<br />
Ground floor to first floor height: a minimum <strong>of</strong> 3.2 metres;<br />
Minimum 4 metre setback from Railway Parade to preserve and/or reinforce the "green"<br />
character <strong>of</strong> the node. Ground level setback to be set aside as quality landscaped space;<br />
New buildings on Southport Street shall incorporate an awning over adjacent footpaths to<br />
provide weather protection to pedestrians;<br />
Street elevations shall be articulated to include defined street front entries which are<br />
clearly identifiable from the street and projections and indentations in the floor plan with<br />
balconies, generous window reveals, related awning and ro<strong>of</strong> elements and changes in<br />
materials.<br />
As amendments are proposed to the current precinct planning policy for West Leederville<br />
(Policy 6.5) to reflect the West Leederville Planning and Urban Design Study, it is considered<br />
that the development controls from the West Leederville Planning and Urban Design Study are<br />
more relevant to the assessment <strong>of</strong> this proposal than the current precinct planning policy for<br />
West Leederville.<br />
The building is three storeys and set back from Railway Parade, and the ground floor to first<br />
floor height is over 4.0 metres. A continuous ground floor awning is proposed for almost the full<br />
length <strong>of</strong> the Southport Street frontage, and continues across the Railway Parade frontage,<br />
covering the proposed alfresco dining area. The street elevations are articulated with glazing,<br />
additional awnings on the upper levels, and feature panels.<br />
The front boundary <strong>of</strong> the site is angled, and the setback <strong>of</strong> the front wall <strong>of</strong> the building, which<br />
is perpendicular to the side boundaries, ranges from nil to 5.0 metres. Therefore the building<br />
does not achieve a 4.0 metre minimum setback as stipulated in the development controls. The<br />
greatest setback <strong>of</strong> 5.0 metres will, however, be adjacent to the corner (and roundabout),<br />
maximising sightlines for vehicles using the roundabout.<br />
The front setback area is proposed to be used for alfresco dining, however the plans submitted<br />
show a large planter box and provision for landscaping on the western side <strong>of</strong> the alfresco<br />
dining area. Depending on the quality and upkeep <strong>of</strong> the landscaping proposed, it may be<br />
sufficient to satisfy the development control objectives in contributing to the “green” character <strong>of</strong><br />
the node. A condition can be included in this regard.<br />
With regard to defined street front entry, the plans show one main pedestrian entrance to the<br />
building which is located <strong>of</strong>f Southport Street. The elevation and 3D perspective provided,<br />
however, do not clearly distinguish or identify these entrances as recommended by the above<br />
proposed development controls and also the current precinct planning policy, for example,<br />
through differences in building materials or additional height on awnings. Clearly identifiable<br />
building entrances are important for users and visitors to the building, and also improve the<br />
appearance <strong>of</strong> the building. A condition can be included in this regard to ensure that the main<br />
entrance to the building is clearly identifiable.<br />
H:\CEO\GOV\COUNCIL MINUTES\11 MINUTES\DECEMBER 2011\B DV.DOCX 54