Contactor <strong>com</strong>bin<strong>at</strong>ions<br />

DIL contactors<br />

5/51<br />

<strong>Moeller</strong> HPL0211-2004/2005<br />

Components for self-assembly<br />

Notes<br />

B<br />

Contactors<br />

K1M<br />

1 3 5<br />

K5M<br />

2 4 6<br />

1 3 5<br />

K3M<br />

2 4 6<br />

1 3 5<br />

2 4 6<br />

K1M<br />

1 3 5<br />

K5M<br />

2 4 6<br />

1 3 5<br />

K3M<br />

2 4 6<br />

1 3 5<br />

2 4 6<br />

A<br />

C<br />

A<br />

C<br />

1<br />

U1<br />

V1<br />

W1<br />

M1<br />

3<br />

M1<br />

V2<br />

W2<br />

U2<br />

Overload relay settings<br />

Accessories<br />

Page<br />

1 Overload relay a 6/11<br />

Accessories a 5/54<br />

I N Starting<br />

A x 0.58<br />

Protection of the motor in Y and d configur<strong>at</strong>ion<br />

B x 1<br />

Only partial motor protection in Y configur<strong>at</strong>ion<br />

F 15 s<br />

15 – 40 s<br />

C x 0.58<br />

No motor protection in Y configur<strong>at</strong>ion<br />

> 40 s<br />

Timing relay set to approx. 10 s<br />

0<br />

S11<br />

I<br />

21<br />

22<br />

13<br />

K1M<br />

14<br />

K1M<br />

14<br />

13<br />

44<br />

K3M<br />

43<br />

14<br />

K5M<br />

13<br />

14<br />

13<br />

17 17<br />

K1T K1T<br />

18 28<br />

22 22<br />

K5M K3M<br />

21 21<br />

Main circuit:<br />

Depending on the coordin<strong>at</strong>ion type required<br />

(i.e. type “1” or type “2”) it must be<br />

established whether the fuse protection and<br />

the input wiring for the mains contactor and<br />

delta contactor are to be <strong>com</strong>mon or<br />

separ<strong>at</strong>e.<br />

K1M<br />

N<br />

A1<br />

A2<br />

N<br />

K1T<br />

A1<br />

K3M<br />

A2<br />

A1<br />

K5M<br />

A2<br />

A1<br />

A2<br />

Control circuit:<br />

If the <strong>com</strong>bin<strong>at</strong>ions are used in the scope of<br />

the IEC/EN 60 204-1, VDE 0113 part 1, point<br />

9.1.1 regarding the supply of control circuits<br />

is to be observed.<br />