DIL contactors<br />
Complete units exceeding 75 kW, <strong>com</strong>fort<br />
DIL contactors<br />
Complete units exceeding 75 kW, <strong>com</strong>fort<br />
5/31<br />
<strong>Moeller</strong> HPL0211-2004/2005<br />
<strong>Moeller</strong> HPL0211-2004/2005<br />
R<strong>at</strong>ed<br />
oper<strong>at</strong>ional<br />
current<br />
Max. r<strong>at</strong>ing for<br />
three-phase motors 50 – 60 Hz<br />
AC-3 AC-3 AC-4<br />
380 V<br />
400 V<br />
220 V<br />
230 V<br />
380 V<br />
400 V<br />
660 V<br />
690 V<br />
1000 V 220 V<br />
230 V<br />
380 V<br />
400 V<br />
660 V<br />
690 V<br />
1000 V<br />
Conventional<br />
free air thermal<br />
current<br />
I th = I e<br />
AC-1 <strong>at</strong> 60 °C<br />
Open<br />
Contact sequence<br />
Can be<br />
<strong>com</strong>bined with<br />
auxiliary<br />
contact module<br />
Type<br />
Article no.<br />
Price<br />
See Price<br />
List<br />
Std.<br />
pack<br />
Notes<br />
Contactors<br />
I e P P P P P P P P I th = I e<br />
A kW kW kW kW kW kW kW kW A<br />
DILM <strong>com</strong>fort contactor<br />
185 55 90 175 108 41 75 127 108 275 A1 1 3 5 13 21 31 43 DILM820-XHI... DILM185/22(RA250)<br />
208193<br />
A2 2 4 6 14 22 32 44<br />
225 70 110 215 108 51 90 155 108 315 DILM225/22(RA250)<br />
208197<br />
250 75 132 240 108 62 110 189 108 350 DILM250/22(RA250)<br />
208201<br />
1 off<br />
Conventional DILM185 to DILH1400 DILH2000<br />
A1/A2 are applied to voltage in<br />
the usual manner.<br />
(+) L1<br />
(–) N<br />
A10<br />
A2<br />
a<br />
(+) L1<br />
(–) N<br />
A10<br />
A2<br />
a<br />
Contactors<br />
A11<br />
A1<br />
A11<br />
A1<br />
300 90 160 286 132 75 132 229 132 400 DILM300/22(RA250)<br />
208205<br />
400 125 200 344 132 92 160 283 132 500 DILM400/22(RA250)<br />
208209<br />
500 155 250 344 132 112 200 344 132 700 DILM500/22(RA250)<br />
208213<br />
Direct from the PLC<br />
A 24 V output from the PLC can be<br />
connected directly to connections<br />
A3/A4.<br />
(+) L1<br />
(–) N<br />
A3<br />
A4<br />
(+) L1<br />
(–) N<br />
TY<br />
TX<br />
A3<br />
A4<br />
DILH <strong>com</strong>fort contactor, AC-1<br />
580 185 315 560 600 143 250 440 509 800 DILM580/22(RA250)<br />
208216<br />
650 205 355 630 600 161 280 494 509 850 DILM650/22(RA250)<br />
208219<br />
750 240 400 720 800 181 315 556 678 900 DILM750/22(RA250)<br />
208222<br />
820 260 450 750 800 209 355 633 678 1000 DILM820/22(RA250)<br />
208225<br />
1000 315 560 1000 1000 260 450 780 1000 1000 DILM1000/22(RA250)<br />
267214<br />
1400 A1 1 3 5 13 21 31 43 DILM820-XHI... DILH1400/22(RAW250)<br />
272441<br />
A2 2 4 6 14 22 32 44<br />
2000 DILH2000/22(RAW250)<br />
272442<br />
1 off<br />
1 off<br />
From low-consumption <strong>com</strong>mand devices<br />
Command devices which can only<br />
be subject to minimal loads such<br />
as circuit board relays, control<br />
circuit devices or position<br />
switches can be connected<br />
directly to A10/A11.<br />
24 V<br />
GND<br />
A10<br />
A11<br />
b<br />
A2<br />
A1<br />
A3<br />
A4<br />
(+) L1<br />
(–) N<br />
A10<br />
A11<br />
A2<br />
A1<br />
A3<br />
a<br />
a<br />
24 V<br />
GND<br />
A10<br />
A11<br />
TY<br />
TX<br />
b<br />
A2<br />
A1<br />
A3<br />
A4<br />
(+) L1<br />
(–) N<br />
A10<br />
A11<br />
TY<br />
A2<br />
A1<br />
A3<br />
a<br />
a<br />
A4<br />
TX<br />
A4<br />
a Standstill in an emergency<br />
(Emergency-Stop)<br />
Notes<br />
660 V, 690 V or 1000 V:<br />
Do not reverse directly<br />
All contactors have an integr<strong>at</strong>ed suppressor.<br />
When oper<strong>at</strong>ing DILM580 to DILH2000 contactors with frequency inverters,<br />
the suppressor on the load side must be removed.<br />
The suppressor on the load side must be removed with DILM580 to DILH2000<br />
contactors when performing a high-voltage test.<br />
Control voltages:<br />
RAW250 q 230 – 250 V AC/DC<br />
RA250 q 110 – 250 V AC/DC<br />
Accessories<br />
Auxiliary contact modules a 5/35<br />
Enclosure a 5/95<br />
Accessories a 5/54<br />
Further actu<strong>at</strong>ing voltages a 5/77<br />