1)<br />

5/30<br />

DIL contactors<br />

Complete units exceeding 75 kW, <strong>com</strong>fort<br />

DIL contactors<br />

Complete units exceeding 75 kW, <strong>com</strong>fort<br />

5/31<br />

<strong>Moeller</strong> HPL0211-2004/2005<br />

<strong>Moeller</strong> HPL0211-2004/2005<br />

R<strong>at</strong>ed<br />

oper<strong>at</strong>ional<br />

current<br />

Max. r<strong>at</strong>ing for<br />

three-phase motors 50 – 60 Hz<br />

AC-3 AC-3 AC-4<br />

380 V<br />

400 V<br />

220 V<br />

230 V<br />

380 V<br />

400 V<br />

660 V<br />

690 V<br />

1000 V 220 V<br />

230 V<br />

380 V<br />

400 V<br />

660 V<br />

690 V<br />

1000 V<br />

Conventional<br />

free air thermal<br />

current<br />

I th = I e<br />

AC-1 <strong>at</strong> 60 °C<br />

Open<br />

Contact sequence<br />

Can be<br />

<strong>com</strong>bined with<br />

auxiliary<br />

contact module<br />

Type<br />

Article no.<br />

Price<br />

See Price<br />

List<br />

Std.<br />

pack<br />

Notes<br />

Contactors<br />

I e P P P P P P P P I th = I e<br />

A kW kW kW kW kW kW kW kW A<br />

DILM <strong>com</strong>fort contactor<br />

185 55 90 175 108 41 75 127 108 275 A1 1 3 5 13 21 31 43 DILM820-XHI... DILM185/22(RA250)<br />

208193<br />

A2 2 4 6 14 22 32 44<br />

225 70 110 215 108 51 90 155 108 315 DILM225/22(RA250)<br />

208197<br />

250 75 132 240 108 62 110 189 108 350 DILM250/22(RA250)<br />

208201<br />

1 off<br />

Conventional DILM185 to DILH1400 DILH2000<br />

A1/A2 are applied to voltage in<br />

the usual manner.<br />

(+) L1<br />

(–) N<br />

A10<br />

A2<br />

a<br />

(+) L1<br />

(–) N<br />

A10<br />

A2<br />

a<br />

Contactors<br />

A11<br />

A1<br />

A11<br />

A1<br />

300 90 160 286 132 75 132 229 132 400 DILM300/22(RA250)<br />

208205<br />

400 125 200 344 132 92 160 283 132 500 DILM400/22(RA250)<br />

208209<br />

500 155 250 344 132 112 200 344 132 700 DILM500/22(RA250)<br />

208213<br />

Direct from the PLC<br />

A 24 V output from the PLC can be<br />

connected directly to connections<br />

A3/A4.<br />

(+) L1<br />

(–) N<br />

A3<br />

A4<br />

(+) L1<br />

(–) N<br />

TY<br />

TX<br />

A3<br />

A4<br />

DILH <strong>com</strong>fort contactor, AC-1<br />

580 185 315 560 600 143 250 440 509 800 DILM580/22(RA250)<br />

208216<br />

650 205 355 630 600 161 280 494 509 850 DILM650/22(RA250)<br />

208219<br />

750 240 400 720 800 181 315 556 678 900 DILM750/22(RA250)<br />

208222<br />

820 260 450 750 800 209 355 633 678 1000 DILM820/22(RA250)<br />

208225<br />

1000 315 560 1000 1000 260 450 780 1000 1000 DILM1000/22(RA250)<br />

267214<br />

1400 A1 1 3 5 13 21 31 43 DILM820-XHI... DILH1400/22(RAW250)<br />

272441<br />

A2 2 4 6 14 22 32 44<br />

2000 DILH2000/22(RAW250)<br />

272442<br />

1 off<br />

1 off<br />

From low-consumption <strong>com</strong>mand devices<br />

Command devices which can only<br />

be subject to minimal loads such<br />

as circuit board relays, control<br />

circuit devices or position<br />

switches can be connected<br />

directly to A10/A11.<br />

24 V<br />

GND<br />

A10<br />

A11<br />

b<br />

A2<br />

A1<br />

A3<br />

A4<br />

(+) L1<br />

(–) N<br />

A10<br />

A11<br />

A2<br />

A1<br />

A3<br />

a<br />

a<br />

24 V<br />

GND<br />

A10<br />

A11<br />

TY<br />

TX<br />

b<br />

A2<br />

A1<br />

A3<br />

A4<br />

(+) L1<br />

(–) N<br />

A10<br />

A11<br />

TY<br />

A2<br />

A1<br />

A3<br />

a<br />

a<br />

A4<br />

TX<br />

A4<br />

a Standstill in an emergency<br />

(Emergency-Stop)<br />

Notes<br />

660 V, 690 V or 1000 V:<br />

Do not reverse directly<br />

All contactors have an integr<strong>at</strong>ed suppressor.<br />

When oper<strong>at</strong>ing DILM580 to DILH2000 contactors with frequency inverters,<br />

the suppressor on the load side must be removed.<br />

The suppressor on the load side must be removed with DILM580 to DILH2000<br />

contactors when performing a high-voltage test.<br />

Control voltages:<br />

RAW250 q 230 – 250 V AC/DC<br />

RA250 q 110 – 250 V AC/DC<br />

Accessories<br />

Auxiliary contact modules a 5/35<br />

Enclosure a 5/95<br />

Accessories a 5/54<br />

Further actu<strong>at</strong>ing voltages a 5/77<br />

<strong>For</strong> <strong>Immedi<strong>at</strong>e</strong> <strong>Delivery</strong> <strong>call</strong> <strong>KM<strong>Parts</strong></strong>.<strong>com</strong> <strong>at</strong> (866) 595-9616