Preamplifier for Pressure Based Flow Monitoring 97211<br />

The single-channel preamplifier is used for signal transmission between a dispensing valve with pressure sensor and<br />

a downstream Loctite ® controller 97152 or 97153. The amplifying factor is adjusted depending on the viscosity of the<br />

product to be processed. The Online Flow Monitor is an ideal tool for quality assurance in automated manufacturing<br />

processes. In order to integrate such a monitoring system in the production process, a special dispensing valve with<br />

an integrated pressure sensor is required (see page 24).<br />

Features:<br />

• Adjustable amplifying factor<br />

with LED signal strength indication<br />

• Power supply to pressure based<br />

sensor<br />

• Single channel<br />

Pressure based valve<br />

Preamplifier for Calorimetric Flow Monitoring 97512<br />

The two-channel preamplifier is used for signal transmission between the dispensing valve with calorimetric<br />

sensor (97830) and a downstream Loctite ® controller 97152 or 97153. Set-up of the amplifying factor is<br />

not required; the valve itself provides permanent self-monitoring of the measuring circuit with status indication.<br />

The Online Flow Monitor is an ideal tool for quality assurance in automated manufacturing processes.<br />

The calorimetric measuring principle requires a minimum cycle time of 1.2 seconds.<br />

Features:<br />

• LED signal strength indication<br />

• Power supply to calorimetric<br />

sensor<br />

• Two channel<br />

Calorimetric valve<br />

Fluorescence Detector<br />

98083E<br />

The Loctite ® Fluorescence Detector with lens is a robust monitoring unit that is designed for visual detection and<br />

monitoring of dispense processes utilising fluorescent adhesives. The integrated light source is a long lasting<br />

UV LED. The fluorescence detector is designed to be interfaced directly with a host PLC.<br />

Technical Specifications:<br />

Input Voltage 24 VDC Output<br />

Capability<br />

Protection IP 67 Size of light<br />

spot<br />

PNP/NPN selectable Optimum working distance 9mm<br />

5mm on the focal<br />

surface<br />