Hand-Held Applicators - Henkel Content Management System
Hand-Held Applicators - Henkel Content Management System
Hand-Held Applicators - Henkel Content Management System
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Preamplifier for Pressure Based Flow Monitoring 97211<br />
The single-channel preamplifier is used for signal transmission between a dispensing valve with pressure sensor and<br />
a downstream Loctite ® controller 97152 or 97153. The amplifying factor is adjusted depending on the viscosity of the<br />
product to be processed. The Online Flow Monitor is an ideal tool for quality assurance in automated manufacturing<br />
processes. In order to integrate such a monitoring system in the production process, a special dispensing valve with<br />
an integrated pressure sensor is required (see page 24).<br />
Features:<br />
• Adjustable amplifying factor<br />
with LED signal strength indication<br />
• Power supply to pressure based<br />
sensor<br />
• Single channel<br />
Pressure based valve<br />
Preamplifier for Calorimetric Flow Monitoring 97512<br />
The two-channel preamplifier is used for signal transmission between the dispensing valve with calorimetric<br />
sensor (97830) and a downstream Loctite ® controller 97152 or 97153. Set-up of the amplifying factor is<br />
not required; the valve itself provides permanent self-monitoring of the measuring circuit with status indication.<br />
The Online Flow Monitor is an ideal tool for quality assurance in automated manufacturing processes.<br />
The calorimetric measuring principle requires a minimum cycle time of 1.2 seconds.<br />
Features:<br />
• LED signal strength indication<br />
• Power supply to calorimetric<br />
sensor<br />
• Two channel<br />
Calorimetric valve<br />
Fluorescence Detector<br />
98083E<br />
The Loctite ® Fluorescence Detector with lens is a robust monitoring unit that is designed for visual detection and<br />
monitoring of dispense processes utilising fluorescent adhesives. The integrated light source is a long lasting<br />
UV LED. The fluorescence detector is designed to be interfaced directly with a host PLC.<br />
Technical Specifications:<br />
Input Voltage 24 VDC Output<br />
Capability<br />
Protection IP 67 Size of light<br />
spot<br />
PNP/NPN selectable Optimum working distance 9mm<br />
5mm on the focal<br />
surface<br />
25