Diaphragm Valve 97135/97136<br />

In combination with a semi-automatic or automatic controller, Diaphragm Valves are suitable for dispensing all low<br />

(97135) to medium (97136) viscosity anaerobic and UV light curable adhesives. All wetted components inside the valve<br />

are PTFE to prevent premature curing. The valve has a simple design that facilitates cleaning, servicing and diaphragm<br />

replacement.<br />

The opening of the diaphragm takes place by pressurising an internal single-acting cylinder. When in idle position, the<br />

valve is held closed by spring pressure. Sealing in idle position is achieved by an internal spring pushing a piston<br />

against the diaphragm, re-seating the diaphragm over the flow path. The diaphragm valve is not suitable for moisture<br />

sensitive products like CAs.<br />

Recommended products: Acrylics, anaerobic adhesives and light curable adhesives<br />

Technical Specifications:<br />

Air Input<br />

min. 5-max. 7 bar (73-100 psi),<br />

filtered to a maximum of 10µm<br />

Dimensions (W x H x D)<br />

Product Outlet Luer-Lock output fitting Weight 300g<br />

Max. Product Pressure 4 bar (60 psi)<br />

ø 32 x 127mm<br />

Features:<br />

• Modular design of valve body<br />

and valve actuator provides<br />

on-line serviceability<br />

• Simple design, cost effective<br />

• Easy to service<br />

Shut-Off Valve 97664/97676<br />

The Shut-Off Valve is used in combination with the Eccentric Rotor Pump 3RD8-L / 4RD6-L / 3RD12-L for dispensing<br />

Loctite silicones (97664) or anaerobic sealants (97676). It is opened and closed by a double acting cylinder and<br />

provides a clean cut-off of the fluid flow from the dispensing nozzle.<br />

The valve is installed between eccentric rotor pump and dispensing needle. A pressure sensor can be screwed<br />

directly into the valve body for monitoring the amount of product dispensed.<br />

Recommended products: High viscosity and pasty sealants<br />

Technical Specifications:<br />

Max. Product 40 bar (580 psi) Dimensions (W x H x D) 142 x 75 x 50mm<br />

Pressure<br />

Air Inlet Port min. 5 bar (73 psi),<br />

max. 10 bar (145 psi)<br />

Air Quality<br />

Filtered, oil-free,<br />

or filtered, oiled<br />

Weight 600g Dispensing Needle<br />

Connector<br />

G 1/8<br />

Features:<br />

• Easy clean-up of product channel<br />

• Non-drip opening and closing<br />

• Self closing with spring return<br />