Fixed-Mounted Design – Economical, Reliable and Variable 460 mm busbar system 60 mm busbar system for space-saving installation with direct adaptation of: • Contactor combinations up to 15 kW • Circuit-breakers up to 160 A • Fuse switch-disconnectors up to 160 A • Clear arrangement of devices • Easy replacement • Installation of up to 40 feeders per cubicle Fixed-mounted fuse switches in strip design With their compact and modular design, the strip design switching devices offer a high packing density. • Cable feeders up to 630 A • High packing density of up to 27 feeders per cubicle • Dead-state fuse replacement Fixed-mounted fuse switch in strip design 60 mm busbar system 16
Capacitor and controller modules for central reactive power compensation Controller module with electronic reactive power controller for door mounting • Self-adaption of the C/k value • Nominal cos phi adjustable from 0.8 ind to 0.98 cap • Manual switching Capacitor modules up to 100 kvar • Fuse switch-disconnector • Capacitor switching contactors • MKK power capacitors • Discharging units • Filter circuit chokes (choked) Choked reactive power compensation 250 kvar 17
- Page 1 and 2: The Variable Low-Voltage Switchboar
- Page 3 and 4: Fig. 1 Power Center, Main distribut
- Page 5 and 6: SIVACON for All Applications in the
- Page 7 and 8: Every circuit-breaker is assigned a
- Page 9 and 10: Plug-on bar system, protected again
- Page 11 and 12: Size 1 withdrawable unit, 30 kW, wi
- Page 13 and 14: All power and control cables are co
- Page 15: Diverse connection possibilities Fu
- Page 19 and 20: Plug-on bus system Lateral guide ra
- Page 21 and 22: SIVACON is capable of communication
- Page 23 and 24: Part-integrating solid wall design
- Page 25 and 26: SIVACON is resistant to internal ar
- Page 27 and 28: Technical Data at a Glance Standard
Fixed-Mounted Design –<br />
Economical, Reliable and Variable<br />
460 mm busbar system<br />
60 mm busbar system for<br />
space-saving installation with<br />
direct adaptation of:<br />
• Contactor combinations<br />
up to 15 kW<br />
• Circuit-breakers<br />
up to 160 A<br />
• Fuse switch-disconnectors<br />
up to 160 A<br />
• Clear arrangement of<br />
devices<br />
• Easy replacement<br />
• Installation of up to<br />
40 feeders per cubicle<br />
Fixed-mounted fuse<br />
switches in strip design<br />
With their compact and<br />
modular design, the strip<br />
design switching devices offer<br />
a high packing density.<br />
• Cable feeders up to 630 A<br />
• High packing density of up<br />
to 27 feeders per cubicle<br />
• Dead-state fuse replacement<br />
Fixed-mounted<br />
fuse switch in<br />
strip design<br />
60 mm busbar<br />
system<br />