EVENT SPECIFIC GUIDELINES 13(ESG-13)<br />

WATER SYSTEM CONTAMINATION<br />

3.2.51. THREAT WARNING RECEIVED or IDENTIFIED<br />

tory agencies, law enforcement, etc.<br />

Immediately notify the following personnel:<br />

• Utilities Division Manager Consider notification of the public,<br />

regulatory agencies, law enforcement, etc.<br />

• CEO<br />

• Director of Fleet, Facilities, <strong>and</strong> <strong>Emergency</strong> Services<br />

• <strong>Water</strong> Transmission Manager<br />

• <strong>Water</strong> Treatment Manager<br />

• Customer Service Supervisor<br />

tory agencies, law enforcement, etc.<br />

Consider notification of the public,<br />

regulatory agencies, law enforcement, etc.<br />

OBJECTIVE: Attempt to determine whether contamination is “Possible” within ONE<br />

HOUR of becoming aware of the Threat Warning. A threat is characterized as “Possible”<br />

when circumstances indicate there Sampling was <strong>and</strong> an Analysis opportunity for contamination. (Obviously, it<br />

won’t always be possible to make this determination within this time frame, depending on<br />

the exact circumstances <strong>and</strong> the<br />

Sampling<br />

amount<br />

<strong>and</strong><br />

of<br />

Analysis<br />

information available.)<br />

Be extremely careful about Is what the threat is said CONFIRMED? over any <strong>and</strong> all “wireless” communication<br />

devices. (Use Radio Code 10-90X in place of the term, “water system contamination”.) All<br />

wireless devices can be monitored by persons with scanners. This includes radios <strong>and</strong> cell<br />

phones. Conversations are Is much the threat more CONFIRMED? likely to be “overheard” when using the 800 MHz<br />

two-way radio system.<br />

Full response actions,<br />

If the Threat Warning is associated Remediation with <strong>and</strong> one Recovery or more water treatment or storage facilities,<br />

<strong>Water</strong> Operators will be immediately dispatched to investigate <strong>and</strong> evaluate the site(s) in<br />

Full response actions,<br />

question. Consider isolating the Remediation facility <strong>and</strong> in Recovery question if it will not unnecessarily <strong>and</strong><br />

negatively affect GSWSA customers.<br />

nd conduct initial Threat Evaluation<br />

If the Threat Warning is associated with a particular area of the water distribution system,<br />

<strong>Water</strong> System Operators will be immediately dispatched to investigate <strong>and</strong> evaluate the<br />

site(s) in question.<br />

If the Threat Warning cannot be associated with any particular area, <strong>Water</strong> Operators should<br />

still be dispatched to conduct thorough security inspections of all water treatment <strong>and</strong><br />

storage facilities. Laboratory Services personnel should be placed on st<strong>and</strong>-by for possible<br />

response to the distribution system.<br />

The Laboratory should begin developing a sampling strategy, based on whatever<br />

information is available at the time.<br />

Complete a “Contamination Threat Evaluation” worksheet, which can be found in the<br />

Action Forms 13 section.<br />

3.2.52. THREAT DETERMINED to be ‘POSSIBLE’<br />

<strong>Gr<strong>and</strong></strong> <strong>Str<strong>and</strong></strong> <strong>Water</strong> & <strong>Sewer</strong> <strong>Authority</strong> 126 CONFIDENTIAL MATERIALS<br />

<strong>Emergency</strong> Management <strong>Plan</strong><br />

SECURITY SENSITIVE<br />

June 7, 2013<br />

NOT FOR PUBLIC DISCLOSURE

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!