GENERAL INFORMATION | SAFETY INFORMATION<br />

In today's environment measuring and test instruments are essential tools for building, repairing and servicing electrical<br />

devices and systems.<br />

The primary objective of modern test instruments is to help the user to perform safety checks, troubleshooting and functional<br />

tests quickly, safely and reliably.<br />

Internationally valid safety standards for the safety of electrical measuring and control equipment are drawn up and ratified<br />

by the IEC (International Electrotechnical Commission). They guarantee that tests are carried out according to the<br />

same criteria and guidelines all over the world.<br />

Measuring and test instruments are tested as follows:<br />

CAT II 600V | 4,000V peak impulse test voltage 12 Ohm source<br />

CAT II 1000V | 6000V peak impulse test voltage 12 Ohm source<br />

CAT III 600V | 6,000V peak impulse test voltage 2 Ohm source<br />

CAT III 1000V | 8000 V peak impulse test voltage 2 Ohm source<br />

CAT IV 600V | 8,000V peak impulse test voltage 2 Ohm source<br />

CAT IV 1000V | 12000V peak impulse test voltage 2 Ohm source<br />

Measuring instruments are classed according to 4 different categories that indicate for which range they are approved.<br />

CAT I | Electrical circuits that are not connected directly to the mains<br />

- Battery-operated electrical devices<br />

- Fused electrical circuits in electronics devices<br />

CAT II | Electrical circuits with no direct electrical connection to the mains<br />

- Socket outlets and long branch lines<br />

- All socket outlets that are more than 10 m removed from CAT III<br />

- All socket outlets that are more than 20 m removed from CAT IV<br />

CAT III | In building installations, for example, distribution boards, cabling, socket outlets<br />

- Supply cables and short supply leads<br />

- Distributor boards<br />

- Socket outlets for large loads with short power supply leads<br />

- Lighting systems in large buildings<br />

- Supplies<br />

- Busbars<br />

CAT IV | At the source of the low current low-voltage installation, for example electricity meters, main terminal, primary<br />

surge protection devices<br />

- In the open and supply cable routing<br />

- Supply cables from connection point to the building<br />

- Connection between the measuring instrument and the connection point<br />

- Overhead lines to individual buildings<br />

- Underground cables to water pumps<br />

Manufacturers are able to provide documentary evidence that their products comply with IEC/EN 61010-1 by having the<br />

product tested for compliance by an independent, recognised certifying body. Following successful compliance testing the<br />

manufacturer is entitled to affix the corresponding GS symbol to his product.<br />

As a safety conscious and responsible manufacturer all Testboy GmbH products are certified by TÜV - Süd GmbH (TÜV =<br />

Technical Inspectorate in Germany).<br />