<strong>Catalyst</strong> 6509-NEB Switch<br />

Chapter 1<br />

Product Overview<br />

Table 1-15<br />

<strong>Catalyst</strong> 6509-NEB Switch Features (continued)<br />

Feature<br />

Features<br />

Power supply • Supports one or two power supplies. The following models are<br />

supported:<br />

Note<br />

– WS-CAC-2500W (2500 W AC-input power supply).<br />

– WS-CDC-2500W (2500 W DC-input power supply).<br />

– WS-CAC-3000W (3000 W AC-input power supply).<br />

– WS-CAC-4000W-US (4000 W AC-input power supply).<br />

– WS-CAC-4000W-INT (4000 W AC-input power supply).<br />

– PWR-4000-DC (4000 W DC-input power supply).<br />

– WS-CAC-6000W (6000 W AC-input power supply).<br />

– PWR-6000-DC (6000 W DC-input power supply).<br />

– WS-CAC-8700W-E (8700 W AC-input power supply).<br />

The 6000 W AC-input and DC-input power supplies and the 8700 W<br />

AC-input power supply are limited to 4000 W maximum output<br />

when installed in the <strong>Catalyst</strong> 6509-NEB chassis.<br />

• Installed power supplies can be of different wattage ratings. Installed<br />

power supplies can also be both AC-input, both DC-input, or one<br />

AC-input and one DC-input. Power supplies can be configured in either<br />

redundant or combined mode.<br />

• All <strong>Catalyst</strong> <strong>6500</strong> series AC-input power supplies require single-phase<br />

source AC. Source AC can be out of phase between multiple power<br />

supplies or multiple AC-power plugs on the same power supply because<br />

all AC power supply inputs are isolated.<br />

• Single power supplies are installed in the left power supply bay. The<br />

second power supply is installed in the right power supply bay.<br />

Note<br />

For proper operation of the power supply OUTPUT FAIL LED,<br />

systems with single power supplies must be configured with a<br />

minimum of one fan tray and one supervisor engine. Systems with<br />

dual power supplies must have a minimum configuration of one fan<br />

tray, one supervisor engine, and one additional module. Failure to<br />

meet these minimum configuration requirements can cause a false<br />

power supply output fail signal.<br />