Catalyst 6506-E Switch Chapter 1 Product Overview Table 1-10 lists the environmental and physical specifications of the Catalyst 6506-E switch chassis. Table 1-10 Catalyst 6506-E Switch Specifications Item Environmental Temperature, operating Temperature, nonoperating and storage Thermal transition Humidity (RH), ambient (noncondensing) operating Humidity (RH), ambient (noncondensing) nonoperating and storage Specification Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 131°F (0° to 55°C) Note The Catalyst 6500 series switches are equipped with internal air temperature sensors that are triggered at 104°F (40°C) generating a minor alarm and at 131°F (55°C) generating a major alarm. Chassis unpackaged: –4° to 149°F (–20° to 65°C) Chassis in protective shipping package: –40° to 158°F (–40° to 70°C) 0.5°C per minute (hot to cold) 0.33°C per minute (cold to hot) 5% to 90% 5% to 95% Altitude, operating Certified for operation: 0 to 6500 ft (0 to 2000 m) Shock and vibration Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m) This switch complies with Network Equipment Building Systems (NEBS) (Zone 4 per GR-63-Core) in the following areas: • Earthquake environment and criteria • Office vibration and criteria • Transportation vibration and criteria Shock • Operational—5 G 30 ms, half-sine (IEC 68-2-27) • Nonoperational—20 G, 7.5 ms, trapezoidal Vibration Operational—3 Hz to 500 Hz. Power Spectral Density (PSD)—0.0005 G 2 /Hz at 10 Hz and 200 Hz. 5 dB/octave roll off at each end. 0.5 hours per axis (1.12 Grms). Acoustic noise 53 to 61 dB. International Organization for Standardization (ISO) 7779: Bystander position operating to an ambient temperature of 86°F (30°C). 1-28 Catalyst 6500 Series Switches Installation Guide OL-5781-08
Chapter 1 Product Overview Catalyst 6506-E Switch Table 1-10 Catalyst 6506-E Switch Specifications (continued) Item Specification Physical characteristics Dimensions (H x W x D) • 19.2 x 17.5 x 18.2 in. (48.8 x 44.5 x 46.0 cm). Airflow Weight • Chassis depth including cable guide is 21.64 in. (55.0 cm). • Chassis requires 12 RU. • The Catalyst 6506-E switch chassis is designed to install in standard 19-inch equipment racks that meet ANSI/EIA 310-D, IEC 60297, and ETS 300-119 standards. Chassis only: 50 lb (22.7 kg). Chassis fully configured with 1 supervisor engine, 5 switching modules, and 2 power supplies: 159 lb (72.3 kg). WS-C6506-E-FAN—564 CFM. Note We recommend that you maintain a minimum air space of 6 inches (16 cm) between walls and the chassis air vents and a minimum horizontal separation of 12 inches (30.5 cm) between two chassis to prevent overheating. OL-5781-08 Catalyst 6500 Series Switches Installation Guide 1-29
- Page 1 and 2: Catalyst 6500 Series Switches Insta
- Page 3: NOTWITHSTANDING ANY OTHER WARRANTY
- Page 6 and 7: Contents Power Source Interruptions
- Page 8 and 9: Contents Attaching the Interface Ca
- Page 10 and 11: Contents 100-MB Transceivers B-1 1-
- Page 12 and 13: Conventions Preface Chapter Title D
- Page 14 and 15: Conventions Preface Warnings use th
- Page 16 and 17: Conventions Preface Varning! VIKTIG
- Page 18 and 19: Conventions Preface xviii Catalyst
- Page 20 and 21: Related Documentation Preface Obtai
- Page 22 and 23: WS-SUP32-GE-3B Catalyst 6503 Switch
- Page 24 and 25: Catalyst 6503 Switch Chapter 1 Prod
- Page 26 and 27: Catalyst 6503 Switch Chapter 1 Prod
- Page 28 and 29: WS-SUP32-GE-3B Catalyst 6503-E Swit
- Page 30 and 31: Catalyst 6503-E Switch Chapter 1 Pr
- Page 32 and 33: Catalyst 6503-E Switch Chapter 1 Pr
- Page 34 and 35: Catalyst 6504-E Switch Chapter 1 Pr
- Page 36 and 37: Catalyst 6504-E Switch Chapter 1 Pr
- Page 38 and 39: WS-X6408 8 PORT GIGABIT ETHERNET WS
- Page 40 and 41: Catalyst 6506 Switch Chapter 1 Prod
- Page 42 and 43: Catalyst 6506 Switch Chapter 1 Prod
- Page 44 and 45: WS-X6408 8 PORT GIGABIT ETHERNET WS
- Page 46 and 47: Catalyst 6506-E Switch Chapter 1 Pr
- Page 50 and 51: WS-X6408 WS-X6408 WS-X6408 WS-X6408
- Page 52 and 53: Catalyst 6509 Switch Chapter 1 Prod
- Page 54 and 55: Catalyst 6509 Switch Chapter 1 Prod
- Page 56 and 57: WS-X6408 WS-X6408 WS-X6408 WS-X6408
- Page 58 and 59: Catalyst 6509-E Switch Chapter 1 Pr
- Page 60 and 61: Catalyst 6509-E Switch Chapter 1 Pr
- Page 62 and 63: FAN STATUS LINK LINK LINK LINK LINK
- Page 64 and 65: Catalyst 6509-NEB Switch Chapter 1
- Page 66 and 67: Catalyst 6509-NEB Switch Chapter 1
- Page 68 and 69: Catalyst 6509-NEB Switch Chapter 1
- Page 70 and 71: Catalyst 6509-NEB-A Switch Chapter
- Page 72 and 73: Catalyst 6509-NEB-A Switch Chapter
- Page 74 and 75: Catalyst 6509-NEB-A Switch Chapter
- Page 76 and 77: Catalyst 6509-V-E Switch Chapter 1
- Page 78 and 79: Catalyst 6509-V-E Switch Chapter 1
- Page 80 and 81: Catalyst 6509-V-E Switch Chapter 1
- Page 82 and 83: Catalyst 6513 Switch Chapter 1 Prod
- Page 84 and 85: Catalyst 6513 Switch Chapter 1 Prod
- Page 86 and 87: Catalyst 6513 Switch Chapter 1 Prod
- Page 88 and 89: WS-X6408 8 PORT GIGABIT ETHERNET WS
- Page 90 and 91: Catalyst 6513-E Switch Chapter 1 Pr
- Page 92 and 93: Catalyst 6513-E Switch Chapter 1 Pr
- Page 94 and 95: Catalyst 6513-E Switch Chapter 1 Pr
- Page 96 and 97: Safety Chapter 2 Preparing for Inst
Chapter 1<br />
Product Overview<br />
<strong>Catalyst</strong> 6506-E Switch<br />
Table 1-10<br />
<strong>Catalyst</strong> 6506-E Switch Specifications (continued)<br />
Item<br />
Specification<br />
Physical characteristics<br />
Dimensions (H x W x D) • 19.2 x 17.5 x 18.2 in. (48.8 x 44.5 x 46.0 cm).<br />
Airflow<br />
Weight<br />
• Chassis depth including cable guide is 21.64 in. (55.0 cm).<br />
• Chassis requires 12 RU.<br />
• The <strong>Catalyst</strong> 6506-E switch chassis is designed to install in standard<br />
19-inch equipment racks that meet ANSI/EIA 310-D, IEC 60297, and<br />
ETS 300-119 standards.<br />
Chassis only: 50 lb (22.7 kg).<br />
Chassis fully configured with 1 supervisor engine, 5 switching modules, and<br />
2 power supplies: 159 lb (72.3 kg).<br />
WS-C6506-E-FAN—564 CFM.<br />
Note<br />
We recommend that you maintain a minimum air space of 6 inches<br />
(16 cm) between walls and the chassis air vents and a minimum<br />
horizontal separation of 12 inches (30.5 cm) between two chassis to<br />
prevent overheating.<br />
OL-5781-08<br />
<strong>Catalyst</strong> <strong>6500</strong> <strong>Series</strong> <strong>Switches</strong> <strong>Installation</strong> <strong>Guide</strong><br />
1-29